Tumor control probability reduction in gated radiotherapy of non‐small cell lung cancers: a feasibility study

R Alfredo Siochi 1,, Yusung Kim 1, Sudershan Bhatia 1
PMCID: PMC5689977  PMID: 25679148

Abstract

We studied the feasibility of evaluating tumor control probability (TCP) reductions for tumor motion beyond planned gated radiotherapy margins. Tumor motion was determined from cone‐beam CT projections acquired for patient setup, intrafraction respiratory traces, and 4D CTs for five non‐small cell lung cancer (NSCLC) patients treated with gated radiotherapy. Tumors were subdivided into 1 mm sections whose positions and doses were determined for each beam‐on time point. (The dose calculation model was verified with motion phantom measurements.) The calculated dose distributions were used to generate the treatment TCPs for each patient. The plan TCPs were calculated from the treatment planning dose distributions. The treatment TCPs were compared to the plan TCPs for various models and parameters. Calculated doses matched phantom measurements within 0.3% for up to 3 cm of motion. TCP reductions for excess motion greater than 5 mm ranged from 1.7% to 11.9%, depending on model parameters, and were as high as 48.6% for model parameters that simulated an individual patient. Repeating the worst case motion for all fractions increased TCP reductions by a factor of 2 to 3, while hypofractionation decreased these reductions by as much as a factor of 3. Treatment motion exceeding gating margins by more than 5 mm can lead to considerable TCP reductions. Appropriate margins for excess motion are recommended, unless applying daily tumor motion verification and adjusting the gating window.

PACS numbers: 87.55.dk, 87.57.Q‐

Keywords: tumor control probability, non‐small cell lung cancer, gated radiotherapy

Supporting information

Supplementary Material

REFERENCES

  • 1. Berbeco RI, Nishioka S, Shirato H, Chen GT, Jiang SB. Residual motion of lung tumors in gated radiotherapy with external respiratory surrogates. Phys Med Biol. 2005;50(16):3655–67. [DOI] [PubMed] [Google Scholar]
  • 2. Tome WA and Fowler JF. On cold spots in tumor subvolumes. Med Phys. 2002;29(7): 1590–98. [DOI] [PubMed] [Google Scholar]
  • 3. Chen M, Siochi RA. Diaphragm motion quantification in megavoltage cone‐beam CT projection images. Med Phys. 2010;37(5):2312–20. [DOI] [PubMed] [Google Scholar]
  • 4. Bissonnette JP, Franks KN, Purdie TG, et al. Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration‐correlated cone beam computed tomography. Int J Radiat Oncol Biol Phys. 2009;75(3):688–95. [DOI] [PubMed] [Google Scholar]
  • 5. Mechalakos J, Yorke E, Mageras GS, et al. Dosimetric effect of respiratory motion in external beam radiotherapy of the lung. Radiother Oncol. 2004;71 (2): 191–200. [DOI] [PubMed] [Google Scholar]
  • 6. Cervino LI, Chao AK, Sandhu A, Jiang SB. The diaphragm as an anatomic surrogate for lung tumor motion. Phys Med Biol. 2009;54(11):3529–41. [DOI] [PubMed] [Google Scholar]
  • 7. Joiner MC and Bentzen SM. Time‐dose relationships: the linear‐quadratic approach. In: Steel GG, editor. Basic clinical radiobiology. London, U.K.: Edward Arnold; 2002. [Google Scholar]
  • 8. Martel MK, Ten Haken RK, Hazuka MB, et al. Estimation of tumor control probability model parameters from 3‐D dose distributions of non‐small cell lung cancer patients. Lung Cancer. 1999;24(1):31–37. [DOI] [PubMed] [Google Scholar]
  • 9. Willner J, Baier K, Caragiani E, Tschammler A, Flentje M. Dose, volume, and tumor control prediction in primary radiotherapy of non‐small‐cell lung cancer. Int J Radiat Oncol Biol Phys. 2002;52(2):382–89. [DOI] [PubMed] [Google Scholar]
  • 10. Guckenberger M, Wulf J, Mueller G, et al. Dose‐response relationship for image‐guided stereotactic body radiotherapy of pulmonary tumors: relevance of 4D dose calculation. Int J Radiat Oncol Biol Phys. 2009;74(1):47–54. [DOI] [PubMed] [Google Scholar]
  • 11. Bentzen SM and Tucker SL. Quantifying the position and steepness of radiation dose‐response curves. Int J Radiat Biol. 1997;71(5):531–42. [DOI] [PubMed] [Google Scholar]
  • 12. Vinogradskiy YY, Balter P, Followill DS, Alvarez PE, White RA, Starkschall G. Comparing the accuracy of four‐dimensional photon dose calculations with three‐dimensional calculations using moving and deforming phantoms. Med Phys. 2009;36(11):5000–06. [DOI] [PubMed] [Google Scholar]
  • 13. Lax I, Panettieri V, Wennberg B, et al. Dose distributions in SBRT of lung tumors: Comparison between two different treatment planning algorithms and Monte‐Carlo simulation including breathing motions. Acta Oncol. 2006;45(7):978–88. [DOI] [PubMed] [Google Scholar]
  • 14. Glide‐Hurst CK, Hugo GD, Liang J, Yan D. A simplified method of four‐dimensional dose accumulation using the mean patient density representation. Med Phys. 2008;35(12):5269–77. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Geneser SE, Kirby RM, Wang B, Salter B, Joshi S. Incorporating patient breathing variability into a stochastic model of dose deposition for stereotactic body radiation therapy. In: Prince JL, Pham DL, Myers KJ, editors. Information processing in medical imaging. Berlin Heidelberg: Springer‐Verlag; 2009. p. 688–700. [DOI] [PubMed] [Google Scholar]
  • 16. Chen M and Siochi RA. Feasibility of using respiratory correlated mega voltage cone beam computed tomography to measure tumor motion. J Appl Clin Med Phys. 2011;12(2):201–12. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Riboldi M, Sharp GC, Baroni G, Chen GT. Four‐dimensional targeting error analysis in image‐guided radiotherapy. Phys Med Biol. 2009;54(19):5995–6008. [DOI] [PubMed] [Google Scholar]
  • 18. Kubo HD, Len PM, Minohara S, Mostafavi H. Breathing‐synchronized radiotherapy program at the University of California Davis Cancer Center. Med Phys. 2000;27(2):346–53. [DOI] [PubMed] [Google Scholar]
  • 19. Goossens S, Senny F, Lee JA, Janssens G, Geets X. Assessment of tumor motion reproducibility with audio‐visual coaching through successive 4D CT sessions. J Appl Clin Med Phys. 2014;15(1):4332. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20. Aristophanous M, Rottmann J, Park SJ, Nishioka S, Shirato H, Berbeco RI. Image‐guided adaptive gating of lung cancer radiotherapy: a computer simulation study. Phys Med Biol. 2010;55(15):4321–33. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Material


Articles from Journal of Applied Clinical Medical Physics are provided here courtesy of Wiley

RESOURCES