Abstract
Aim
For accurate interpretation of echocardiographic measurements normative data are required, which are provided by guidelines. For this article, the hypothesis was that these cannot be extrapolated to the Dutch population, since in Dutch clinical practice often higher values are found, which may not be pathological but physiological. Therefore this study aimed to 1) obtain and propose normative values for cardiac chamber quantification in a healthy Dutch population and 2) determine influences of baseline characteristics on these measurements.
Methods
Prospectively recruited healthy subjects, aged 20–72 years (at least 28 subjects per age decade, equally distributed for gender) underwent physical examination and 2D and 3D echocardiography. Both ventricles and atria were assessed and volumes were calculated.
Results
147 subjects were included (age 44 ± 14 years, 50% female). Overall, feasibility was good for both linear and volumetric measurements. Linear and volumetric parameters were consistently higher than current guidelines recommend, while functional parameters were in line with the guidelines. This was more so in the older population. 3D volumes were higher than 2D volumes. Gender dependency was seen in all body surface area (BSA) corrected volumes and with increasing age, ejection fractions decreased.
Conclusion
This study provides 2D and 3D echocardiographic reference ranges for both ventricles and atria derived from a healthy Dutch population. BSA indexed volumes are gender-dependent, age did not influence ventricular volumes and a rise in blood pressure was independently associated with increased right ventricular volumes. The higher volumes found may be indicative for the Dutch population being the tallest in the world.
Keywords: Echocardiography, 3D, Normal values, Chamber quantification
Introduction
Echocardiography is indispensable in clinical practice. It is the most widely used non-invasive imaging tool to assess and quantify cardiac structural and functional parameters, mainly because of its versatility: it is widely available, relatively cost-effective and mobile. To interpret the performed measurements, solid normative data are essential. The recently revised guideline for cardiac chamber quantification provides guidance for echocardiographic assessment [1, 2]. For some measurements, age- and gender-specific values are reported.
In the literature, there are four studies that show an influence of gender and age on left ventricular (LV) and right ventricular (RV) volumes [3]. However, besides age and gender, there are implications that ethnicity also influences cardiac size and function [4–7]. Echocardiographic measurements performed in healthy Dutch people, the tallest people worldwide [8], often supersede the upper limits of normal (ULN) given by current guidelines though most indices are corrected with body surface area (BSA). This implies that BSA correction does not fully equalise differences originating from height. Also, a study comparing Caucasians with Asian Indians showed smaller 3D LV volumes in Asians but with a comparable ejection fraction (EF). However, ethnic-specific normal values for the Dutch population are not yet available.
Therefore, this study aims to provide 1) age-specific reference values for echocardiographic chamber measurements specifically in a Dutch population and 2) identify the influence of age, gender, body mass index (BMI), BSA and blood pressure on the echocardiographic measurements.
Methods
Patient population
Healthy volunteers, aged 20–72 years, were enrolled in 2014–2015 for this prospective cross-sectional study and were stratified into five groups: 20–29, 30–39, 40–49, 50–59 and 60–72 years (each 50% female). Details have been published earlier [9]. Healthy subjects were examined at the cardiology outpatient clinic of the Erasmus Medical Centre, Rotterdam. Exclusion criteria were: (prior) cardiovascular disease, systemic disease, or cardiac medication, the finding of cardiac abnormalities during examination or cardiovascular risk factors consisting of hypertension (systolic and diastolic blood pressure >140/80 mm Hg), diabetes mellitus and hypercholesterolaemia. Professional athletes, morbidly obese subjects (BMI >40 kg/m2), pregnant women and women with breast implants were excluded. This study was carried out according to the principles of the Declaration of Helsinki and approved by the local ethics committee. Written informed consent was obtained from all patients.
Clinical assessment
The study consisted of a questionnaire on medical history and health status, physical examination, venous blood sampling, 12-lead electrocardiogram and an echocardiogram.
Echocardiographic image acquisition
Echocardiographic studies were carried out by one of two experienced sonographers. Two-dimensional greyscale harmonic images were obtained in the left lateral decubitus position using an i33 or EPIQ7 ultrasound system (Philips Medical Systems, Best, the Netherlands) equipped with a transthoracic broadband X5-1 matrix transducer (composed of 3,040 elements with 1–5 MHz). Dedicated views were taken for assessment of both atria and ventricles. The studies were stored in Digital Imaging and Communications in Medicine (DICOM) format.
Echocardiographic measurements
The current recommendations for chamber quantification were used [1]. LV end-diastolic and -systolic diameters were measured in the parasternal short axis view, together with their respective volumes using the apical four- and two-chamber views. Volumes were measured using the method-of-disk summation technique.
The left atrial (LA) area was measured in dedicated atrial four- and two-chamber views to avoid foreshortening. Biplane volumes were measured using the method-of-disk summation technique.
For the right ventricle, end-diastolic and -systolic areas (EDA and ESA) were measured in order to calculate the fractional area change:
1 |
End-diastolic basal- and mid-cavity diameters were measured in the modified apical four-chamber view. The proximal and distal outflow tract diameters were measured in the parasternal short-axis view (Fig. 1). Tricuspid annular plane systolic excursion (TAPSE) was measured.
For the right atrium, the single plane volume was measured in the apical four-chamber view using the method-of-disk summation technique and the area length method.
Three-dimensional measurements
LV volumetric measurements were performed with TomTec 4D LV function suite (4D LV Analysis; TomTec Imaging Systems, Unterschleissheim, Germany) using a semi-automated endocardial border trace, after the apex and the middle of the mitral valve annulus are determined by the operator. The end systolic and diastolic frame are automatically detected in order to start contour detection. Corrections to the endocardial trace were manually applied by the operator if needed. For the right ventricle, a similar routine was used (TomTec 4D RV function; TomTec Imaging Systems, Unterschleissheim, Germany).
Statistical analysis
Normal distribution was checked using Shapiro-Wilks tests and histograms. Depending on data distribution, continuous data are presented as mean ± standard deviation (SD) or median with first-third quartile (Q1-Q3). Categorical data are presented as frequencies and percentages. Student’s t‑test, the Mann-Whitney-U test, χ2-test or Fisher’s exact test was used when appropriate. Correlations were measured using the Pearson correlation test. For correlations between echocardiographic parameters and age, linear regression analysis was applied. Variables that reached significance and did not show collinearity with other variables were included in a multivariable model. When collinearity did occur, the variable with the highest correlation coefficient was included. A p ≤ 0.05 was considered statistically significant. Statistical analysis was done using the Statistical Package for Social Science version 21 (IBM DPDD Statistics for Windows, Armonk, New York, USA).
Results
Of the 155 subjects eligible, 147 were included (mean age 44.6 ± 13.7 years, 50% female) (Fig. 2). Tab. 1 shows the characteristics of the study population. LV volume and function assessment with 3D echocardiography was feasible in 121 (82.3%) volunteers; RV volume and function assessment with 3D echocardiography was feasible in 97 (66.0%) volunteers. Height, weight, BMI, BSA and systolic and diastolic blood pressure were significantly lower in women.
Table 1.
Total population | Male | Female | |
---|---|---|---|
n = 147 | n = 73 | n = 74 | |
Age (years) | 44.6 ± 13.8 | 44.0 ± 13.7 | 45.3 ± 13.8 |
Height (cm) | 175 ± 9 | 181 ± 7 | 169 ± 6 |
Weight (kg) | 75 ± 13 | 82 ± 11 | 67 ± 9 |
Body mass index (kg/m2) | 24.4 ± 3.3 | 25.2 ± 3.3 | 23.6 ± 3.0 |
Body surface area (m2) | 1.89 ± 0.19 | 2.03 ± 0.15 | 1.76 ± 0.12 |
Systolic blood pressure (mm Hg) | 127 ± 15 | 131 ± 16 | 123 ± 12 |
Diastolic blood pressure (mm Hg) | 80 ± 9 | 82 ± 9 | 77 ± 9 |
Heart rate (beats per minute) | 71 ± 12 | 69 ± 12 | 72 ± 12 |
Echocardiographic chamber measurements in relation with age
Tab. 2 presents an overview of echocardiographic parameters per age decade. For 3D derived volumes, the averages for the left ventricle were: end-diastolic volume (EDV) 78 ± 12 ml/m2 and end-systolic volume (ESV) 34 ± 6 ml/m2. For the right ventricle, values were 58 ± 12 ml/m2 and 24 ± 6 ml/m2. LV and RV volumes were not age-dependent; this was true for both 2D and 3D echocardiography. Age was inversely correlated with LVEF (57 ± 4 ml/m2 in the youngest group and 55 ± 3 ml.m2 in the oldest group (r: −0.229, p: 0.012)). RVEF was 58 ± 4 ml/m2 and was not correlated with age. Importantly, volumetric measurements acquired with 2D echocardiography all exceeded the ULN as recommended in the guideline. This was also true for 3D LV volumes, but not for the 3D RV volumes.
Table 2.
Total population | 20–29 years | 30–39 years | 40–49 years | 50–59 years | 60–72 years | |||
---|---|---|---|---|---|---|---|---|
n = 147 | n = 32 | n = 28 | n = 28 | n = 31 | n = 28 | R | p-value | |
2D measurements | ||||||||
Left ventricle | ||||||||
EDV (ml/m2) | 62.4 ± 10.1 | 63.9 ± 9.5 | 63.1 ± 9.9 | 64.1 ± 11.0 | 60.5 ± 8.0 | 60.6 ± 12.2 | ns | 0.061 |
ESV (ml/m2) | 24.9 ± 5.8 | 25.4 ± 5.1 | 24.7 ± 6.2 | 26.3 ± 5.5 | 23.2 ± 5.1 | 25.0 ± 6.9 | ns | 0.349 |
EF (%) | 60.4 ± 4.7 | 60.4 ± 3.6 | 61.4 ± 5.0 | 59.2 ± 4.5 | 61.9 ± 5.3 | 59.2 ± 4.5 | ns | 0.596 |
EDD (mm) | 46 ± 4 | 46 ± 3 | 47 ± 3 | 45 ± 4 | 45 ± 5 | 44 ± 5 | 0.248 | 0.003 |
ESD (mm) | 28 ± 4 | 29 ± 3 | 28 ± 3 | 28 ± 5 | 28 ± 4 | 28 ± 6 | ns | 0.566 |
Right ventricle | ||||||||
EDA (cm2/m2) | 13.2 ± 2.3 | 14.2 ± 2.3 | 13.5 ± 2.5 | 12.9 ± 1.8 | 12.3 ± 2.0 | 12.6 ± 2.4 | 0.275 | 0.001 |
ESA (cm2/m2) | 7.7 ± 1.7 | 8.3 ± 1.6 | 7.7 ± 1.7 | 7.4 ± 1.6 | 7.3 ± 1.7 | 7.2 ± 2.0 | 0.219 | 0.014 |
FAC (%) | 42.8 ± 7.3 | 41.2 ± 6.6 | 43.6 ± 6.2 | 42.6 ± 8.5 | 42.6 ± 8.7 | 44.5 ± 7.2 | ns | 0.198 |
D1 (mm) | 39 ± 5 | 39 ± 5 | 38 ± 5 | 39 ± 6 | 38 ± 4 | 40 ± 6 | ns | 0.804 |
D2 (mm) | 29 ± 5 | 30 ± 6 | 28 ± 4 | 31 ± 5 | 28 ± 5 | 30 ± 6 | ns | 0.795 |
RVOT proximal PLAX (mm) | 32 ± 4 | 30 ± 4 | 30 ± 4 | 31 ± 4 | 33 ± 5 | 34 ± 4 | 0.355 | <0.001 |
RVOT proximal SAX (mm) | 31 ± 4 | 31 ± 4 | 30 ± 4 | 32 ± 4 | 32 ± 5 | 31 ± 3 | 0.174 | 0.047 |
RVOT distal SAX (mm) | 22 ± 3 | 22 ± 2 | 23 ± 2 | 21 ± 3 | 23 ± 2 | 23 ± 3 | ns | 0.326 |
Longitudinal diameter (mm) | 82 ± 8 | 84 ± 7 | 86 ± 8 | 81 ± 8 | 81 ± 7 | 79 ± 7 | 0.181 | 0.029 |
TAPSE (mm) | 26 ± 4 | 26 ± 4 | 27 ± 3 | 25 ± 4 | 26 ± 3 | 26 ± 4 | ns | 0.267 |
Left atrium | ||||||||
Length A4C (mm) | 5.0 ± 0.6 | 4.9 ± 0.6 | 5.0 ± 0.6 | 5.0 ± 0.5 | 5.1 ± 0.5 | 5.2 ± 0.7 | ns | 0.064 |
Area A4C (cm2) | 17.3 ± 3.2 | 16.6 ± 2.4 | 17.2 ± 3.0 | 17.1 ± 3.8 | 17.8 ± 2.4 | 17.8 ± 4.0 | ns | 0.134 |
Max volume (ml/m2) | 28.8 ± 7.2 | 27.8 ± 5.7 | 28.1 ± 6.6 | 29.0 ± 9.2 | 29.4 ± 5.5 | 30.0 ± 9.1 | ns | 0.170 |
Right atrium | ||||||||
Length (cm/m2) | 2.6 ± 0.3 | 2.6 ± 0.3 | 2.6 ± 0.3 | 2.5 ± 0.3 | 2.6 ± 0.3 | 2.8 ± 0.3 | ns | 0.089 |
Area (cm/m2) | 8.9 ± 1.5 | 8.8 ± 1.3 | 9.3 ± 1.5 | 8.5 ± 1.4 | 8.6 ± 1.7 | 9.2 ± 1.2 | ns | 0.866 |
Max volume (ml/m2) | 24.5 ± 7.0 | 24.4 ± 6.0 | 26.7 ± 8.4 | 23.3 ± 6.5 | 23.2 ± 7.9 | 24.8 ± 5.7 | ns | 0.343 |
3D measurements | ||||||||
Left ventricle | ||||||||
EDV (ml/m2) | 77.5 ± 12.3 | 81.2 ± 12.1 | 77.1 ± 8.9 | 77.2 ± 10.7 | 75.6 ± 8.9 | 75.1 ± 18.9 | ns | 0.054 |
ESV (ml/m2) | 33.9 ± 6.2 | 34.9 ± 6.2 | 32.9 ± 4.9 | 34.0 ± 5.2 | 33.4 ± 5.8 | 33.9 ± 8.8 | ns | 0.603 |
EF (%) | 56.3 ± 3.7 | 57.0 ± 3.6 | 57.4 ± 3.1 | 55.9 ± 4.1 | 56.0 ± 4.3 | 54.8 ± 2.9 | −0.229 | 0.012 |
Right ventricle | ||||||||
EDV (ml/m2) | 57.7 ± 11.9 | 58.2 ± 14.3 | 54.9 ± 7.0 | 56.4 ± 12.1 | 58.5 ± 10.2 | 61.5 ± 15.0 | ns | 0.403 |
ESV (ml/m2) | 24.3 ± 5.8 | 23.7 ± 6.8 | 22.7 ± 4.4 | 24.2 ± 6.0 | 24.3 ± 4.8 | 27.5 ± 6.5 | ns | 0.054 |
EF (%) | 58.0 ± 4.2 | 59.1 ± 3.7 | 59.0 ± 4.3 | 57.3 ± 4.7 | 58.7 ± 4.1 | 54.9 ± 3.1 | −0.298 | 0.003 |
EDV end-diastolic volume, ESV end-systolic volume, EF ejection fraction, EDD end-diastolic diameter, ESD end-systolic diameter, EDA end-diastolic area, ESA end-systolic area, FAC fractional area change, RVOT right ventricular outflow tract, SAX short-axis view, TAPSE tricuspid annular plane systolic excursion.
Echocardiographic chamber measurements in relation with gender
Tab. 3 shows echocardiographic chamber measurements per gender. Fig. 3 shows 2D measurements for both ventricles (error bars at 2SD), with bars depicting the ULN (solid line) or lower limit (dotted line) of normal according to the guidelines [1]. Most of the measured variables showed gender-dependency. 2D and 3D LV and RV dimensions and volumes were gender-dependent. 2D and 3D EF was also gender-dependent with the exception of 3D RVEF. After BSA indexation, males had higher ventricular volumes. BSA indexation of LA volume negated gender differences, but BSA indexed right atrial (RA) volumes remained bigger in men than women. On average, LA maximum volume was 28.8 ± 7.2 ml/m2, with 25% of the study population having LA dilatation (>34 ml/m2) according to the guideline. In this study, the ULN was 43.2 ml/m2.
Table 3.
Total population | Male | Female | ||
---|---|---|---|---|
n = 147 | n = 73 | n = 74 | p-value | |
2D measurements | ||||
Left ventricle | ||||
2D EDV (ml/m2) | 62.4 ± 10.1 | 66.5 ± 9.3 | 58.6 ± 9.4 | <0.001 |
2D ESV (ml/m2) | 24.9 ± 5.8 | 27.2 ± 5.3 | 22.7 ± 5.3 | <0.001 |
2D EF (%) | 60.4 ± 4.7 | 59.2 ± 4.3 | 61.6 ± 4.8 | 0.002 |
EDD (mm) | 46 ± 4 | 47 ± 4 | 45 ± 4 | 0.002 |
ESD (mm) | 28 ± 4 | 29 ± 5 | 28 ± 4 | 0.026 |
Right ventricle | ||||
EDA (cm2/m2) | 13.2 ± 2.3 | 13.9 ± 2.2 | 12.5 ± 2.2 | <0.001 |
ESA (cm2/m2) | 7.7 ± 1.7 | 8.2 ± 1.8 | 7.1 ± 1.6 | <0.001 |
FAC (%) | 42.8 ± 7.3 | 41.4 ± 7.7 | 44.0 ± 6.8 | 0.048 |
D1 (mm) | 39 ± 5 | 41 ± 5 | 37 ± 4 | <0.001 |
D2 (mm) | 29 ± 5 | 32 ± 5 | 27 ± 5 | <0.001 |
RVOT proximal PLAX (mm) | 32 ± 4 | 33 ± 5 | 31 ± 4 | 0.037 |
RVOT proximal SAX (mm) | 31 ± 4 | 32 ± 4 | 31 ± 4 | 0.013 |
RVOT distal SAX (mm) | 22 ± 3 | 23 ± 3 | 22 ± 3 | 0.15 |
Longitudinal diameter (mm) | 82 ± 8 | 85 ± 7 | 80 ± 7 | 0.014 |
TAPSE (mm) | 26 ± 4 | 26 ± 4 | 26 ± 4 | 0.344 |
Left atrium | ||||
Length A4C (mm) | 5.0 ± 0.6 | 5.2 ± 0.6 | 4.9 ± 0.6 | 0.019 |
Area A4C (cm2) | 17.3 ± 3.2 | 17.8 ± 3.4 | 16.9 ± 2.8 | 0.086 |
Biplane max volume (ml/m2) | 28.8 ± 7.2 | 27.9 ± 7.5 | 29.8 ± 6.9 | 0.135 |
Right atrium | ||||
Length (cm/m2) | 2.6 ± 0.3 | 2.5 ± 0.3 | 2.7 ± 0.3 | <0.001 |
Area (cm/m2) | 8.9 ± 1.5 | 8.9 ± 1.6 | 8.8 ± 1.3 | 0.626 |
Single plane MOD max volume (ml/m2) | 24.5 ± 7.0 | 25.8 ± 8.1 | 23.3 ± 5.7 | 0.038 |
3D measurements | ||||
Left ventricle | ||||
3D EDV (ml/m2) | 77.5 ± 12.3 | 80.7 ± 13.6 | 74.2 ± 9.9 | 0.003 |
3D ESV (ml/m2) | 33.9 ± 6.2 | 35.9 ± 6.7 | 31.8 ± 5.0 | <0.001 |
3D EF (%) | 56.3 ± 3.7 | 55.5 ± 3.3 | 57.1 ± 3.9 | 0.017 |
Right ventricle | ||||
3D EDV (ml/m2) | 57.7 ± 11.9 | 61.3 ± 12.3 | 54.0 ± 10.4 | 0.002 |
3D ESV (ml/m2) | 24.3 ± 5.8 | 26.0 ± 6.2 | 22.5 ± 4.9 | 0.003 |
3D EF (%) | 58.0 ± 4.2 | 57.5 ± 4.1 | 58.4 ± 4.3 | 0.315 |
EDV end-diastolic volume, EF ejection fraction, EDD end-diastolic diameter, ESD end-systolic diameter, EDA end-diastolic area, ESA end-systolic area, FAC fractional area change, RVOT right ventricular outflow tract, PLAX parasternal long-axis, SAX short-axis, TAPSE tricuspid annular plane systolic excursion
Fig. 4 shows age- and gender-specific volumes for both the LV and RV 3D data and the ULN according to the guideline are again depicted. EF for both ventricles was significantly correlated with age, EDV and ESV did not correlate.
Correlations
BSA correlated strongest with echocardiographic parameters compared with height, weight or BMI. Ventricular volumes were not correlated with age, and LVEF and RVEF showed a decrease with age. RV volumes showed a linear increase with higher blood pressure and heart rate, also after correcting for heart rate, QRS duration and gender.
Agreement between 2D and 3D for the LV measurements was moderate: LV EDV: r: 0.643, p < 0.001, and LV ESV r: 0.583, p < 0.001, respectively. For the RV correlations between 2D volumes and 3D areas were weak: 3D EDV vs 2D EDA r: 0.295, p: 0.004 and ESV r: 0.295, p: 0.005 respectively.
Discussion
This prospective study presents normative data for echocardiographic chamber quantification, age- and gender-specific, in a healthy Dutch population. Overall, linear and volumetric parameters exceeded the ULN as stated in the guideline, while functional parameters agreed with them. BSA remains the best variable for indexation.
Feasibility
Feasibility of LV measurements in this study is in line with previous studies [4, 10, 11]. Feasibility is important when a technique is considered for clinical use and the percentages in this study are good, especially since subjects with a poor acoustic window were not excluded. The need for implementation of 3D echocardiography for LV volume and EF in clinical use is high. The lower feasibility for the right ventricle was expected given its location in the thorax right behind the sternum. Higher percentages have been reported in the literature but poor acoustic windows were an exclusion criterion whereas this was not the case for this study [3].
Differences with guidelines
Comparing the results from this study to the ULN as stated in the guideline[1], we found some discrepancies. For most of the parameters, ULN of this study exceeded those of the guideline. This was true for linear and volumetric measurements, regardless of which ventricle or atrium the parameter belonged to: both were larger, this is especially outspoken in the elderly. For instance, when looking at 2D LV volumes: the older the group, the larger the difference. The higher linear and volumetric parameters found may be indicative to the Dutch people being the tallest people in the world, which stresses the importance of specific normative echocardiographic data for the Dutch population. Comparing our data with results from the NORRE trial, a European multicentre study pertaining to primarily white individuals, we found that our volumes and dimensions were generally higher [12]. Mean BSA in their study was 1.8 ± 0.2 vs our 1.89 ± 0.19 m2. This was due to both a higher weight (65 ± 12 vs 75 ± 13 kg) and height (169.8 ± 9.6 vs 175 ± 9 cm), meaning that these higher values are not due to leaner subjects.
Given that the Dutch population is the tallest worldwide [8], the question arose whether BSA was the best parameter for indexation. Univariate analysis in this study showed that BSA correlated strongest when compared with height, weight or BMI; it was indeed the best candidate for indexation. Most parameters exceeded the guideline, with one exception: 3D derived volumes of the right ventricle were in line with the guideline and current literature [3]. Functional parameters concerning LV and RV systolic function (EF, RV FAC and TAPSE) agreed with the proposed values in the guideline, meaning that the current guideline is applicable for the Dutch population.
Multiple studies reported on the negative relation between age and echocardiographic LV volumes[10, 11, 13], which is similar to what is seen in CMR studies [14, 15]. In this study, LV volumes did not decrease with age while LVEF did. For the RV, there was no positive linear correlation in RVEF as is reported by Maffessanti et al. (r 0.240, p < 0.01) [3] , but a negative correlation. This probably reached significance because of the lower mean RVEF in the oldest group. Between the age groups 20–29 to 50–59 years, values remain practically the same. Indeed, the correlation between age and RVEF became stronger when the study population was divided into groups ≤55 years and >55 years. Maffessanti et al. reported similar values, but in their cohort the oldest group (age >70 years) reported higher values for RVEF. Perhaps RVEF does not increase until old age (>70 years), which might explain why our results are different. Clearly, the influence of age needs further exploration.
Correlations with blood pressure
Hypertension was a reason for exclusion, but it is worth mentioning that some volunteers had a higher blood pressure but when checked again by a general practitioner were found to be normal. These volunteers were not excluded. Analysis showed that higher blood pressure led to higher RV volumes. This could imply that sufficient blood pressure regulation could influence the right ventricle.
Clinical implications
The reference values in this study could lead to some changes in clinical decision-making. Though most guidelines use functional parameters, there are situations where volumes or linear dimensions are being used. For instance, when diagnosing LV diastolic dysfunction, LA dilatation plays an important role [16]. With that in mind, in patients suspected of heart failure with mid-range EF, LA enlargement is used to substantiate the diagnosis [17]. An enlarged left atrium is also a strong prognosticator in, for instance, in the recurrence of atrial fibrillation after surgery [18].
RV size is of particular importance for patients with adult congenital heart disease. In patients with an atrial septal defect, if the right ventricle is enlarged intervention is warranted; this is also true for patients with ventricular septal defect [19].
The impact is smaller regarding valvular disease; LV linear dimensions are still used as opposed to volumes [20], and values of LV linear dimensions in this study did agree with guidelines.
Limitations
Considering the size and Dutch ethnicity of the study population, conclusions drawn should be interpreted with caution.
Conclusion
This study presents age- and gender-specific normative data specifically for the native Dutch population, and reveals that linear and volumetric parameters exceed the ULN while functional parameters agree with the guideline. The higher linear and volumetric parameters found may be indicative to native Dutch people being the tallest people worldwide. The authors suggest specific normative values for echocardiographic assessment in the Dutch population.
Funding
This study was supported by a grant from the Thorax Foundation.
Conflict of interest
R.W.J. van Grootel, M.E. Menting, J. McGhie, J.W. Roos-Hesselink, and A.E. van den Bosch declare that they have no competing interests.
References
- 1.Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2015;16:233–270. doi: 10.1093/ehjci/jev014. [DOI] [PubMed] [Google Scholar]
- 2.Bhave NM, Lang RM. Evaluation of left ventricular structure and function by three-dimensional echocardiography. Curr Opin Crit Care. 2013;19:387–396. doi: 10.1097/MCC.0b013e328364d75e. [DOI] [PubMed] [Google Scholar]
- 3.Maffessanti F, Muraru D, Esposito R, et al. Age-, body size-, and sex-specific reference values for right ventricular volumes and ejection fraction by three-dimensional echocardiography: a multicenter echocardiographic study in 507 healthy volunteers. Circ Cardiovasc Imaging. 2013;6:700–710. doi: 10.1161/CIRCIMAGING.113.000706. [DOI] [PubMed] [Google Scholar]
- 4.Chahal NS, Lim TK, Jain P, Chambers JC, Kooner JS, Senior R. Population-based reference values for 3D echocardiographic LV volumes and ejection fraction. JACC Cardiovasc Imaging. 2012;5:1191–1197. doi: 10.1016/j.jcmg.2012.07.014. [DOI] [PubMed] [Google Scholar]
- 5.Rodriguez CJ, Diez-Roux AV, Moran A, et al. Left ventricular mass and ventricular remodeling among Hispanic subgroups compared with non-Hispanic blacks and whites: MESA (Multi-ethnic Study of Atherosclerosis) J Am Coll Cardiol. 2010;55:234–242. doi: 10.1016/j.jacc.2009.08.046. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Kawut SM, Lima JA, Barr RG, et al. Sex and race differences in right ventricular structure and function: the multi-ethnic study of atherosclerosis-right ventricle study. Circulation. 2011;123:2542–2551. doi: 10.1161/CIRCULATIONAHA.110.985515. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Chahal NS, Lim TK, Jain P, Chambers JC, Kooner JS, Senior R. Ethnicity-related differences in left ventricular function, structure and geometry: a population study of UK Indian Asian and European white subjects. Heart. 2010;96:466–471. doi: 10.1136/hrt.2009.173153. [DOI] [PubMed] [Google Scholar]
- 8.Collaboration NCDRF. A century of trends in adult human height. Elife. 2016;5. 10.7554/eLife.13410 [DOI] [PMC free article] [PubMed]
- 9.Menting ME, McGhie JS, Koopman LP, et al. Normal myocardial strain values using 2D speckle tracking echocardiography in healthy adults aged 20 to 72 years. Echocardiography. 2016;33:1665–1675. doi: 10.1111/echo.13323. [DOI] [PubMed] [Google Scholar]
- 10.Fukuda S, Watanabe H, Daimon M, et al. Normal values of real-time 3‑dimensional echocardiographic parameters in a healthy Japanese population: the JAMP-3D Study. Circ J. 2012;76:1177–1181. doi: 10.1253/circj.CJ-11-1256. [DOI] [PubMed] [Google Scholar]
- 11.Muraru D, Badano LP, Peluso D, et al. Comprehensive analysis of left ventricular geometry and function by three-dimensional echocardiography in healthy adults. J Am Soc Echocardiogr. 2013;26:618–628. doi: 10.1016/j.echo.2013.03.014. [DOI] [PubMed] [Google Scholar]
- 12.Kou S, Caballero L, Dulgheru R, et al. Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study. Eur Heart J Cardiovasc Imaging. 2014;15:680–690. doi: 10.1093/ehjci/jet284. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Kaku K, Takeuchi M, Otani K, et al. Age- and gender-dependency of left ventricular geometry assessed with real-time three-dimensional transthoracic echocardiography. J Am Soc Echocardiogr. 2011;24:541–547. doi: 10.1016/j.echo.2011.01.011. [DOI] [PubMed] [Google Scholar]
- 14.Germans T, Gotte MJ, Nijveldt R, et al. Effects of aging on left atrioventricular coupling and left ventricular filling assessed using cardiac magnetic resonance imaging in healthy subjects. Am J Cardiol. 2007;100:122–127. doi: 10.1016/j.amjcard.2007.02.060. [DOI] [PubMed] [Google Scholar]
- 15.Sandstede J, Lipke C, Beer M, et al. Age- and gender-specific differences in left and right ventricular cardiac function and mass determined by cine magnetic resonance imaging. Eur Radiol. 2000;10:438–442. doi: 10.1007/s003300050072. [DOI] [PubMed] [Google Scholar]
- 16.Nagueh SF, Smiseth OA, Appleton CP, et al. Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2016;17:1321–1360. doi: 10.1093/ehjci/jew082. [DOI] [PubMed] [Google Scholar]
- 17.Ponikowski P, Voors AA, Anker SD, et al. ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC). Developed with the special contribution of the Heart Failure Association (HFA) of the ESC. Eur J Heart Fail. 2016;2016(18):891–975. doi: 10.1002/ejhf.592. [DOI] [PubMed] [Google Scholar]
- 18.Kirchhof P, Benussi S, Kotecha D, et al. ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Eur Heart J. 2016;2016:2893–2962. doi: 10.1093/eurheartj/ehw210. [DOI] [PubMed] [Google Scholar]
- 19.Baumgartner H, Bonhoeffer P, De Groot NM, et al. ESC Guidelines for the management of grown-up congenital heart disease (new version 2010) Eur Heart J. 2010;31:2915–2957. doi: 10.1093/eurheartj/ehq249. [DOI] [PubMed] [Google Scholar]
- 20.Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology, European Association for Cardio-Thoracic Surgery, Vahanian A, Alfieri O, Andreotti F, et al. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J. 2012;33:2451–96. [DOI] [PubMed]