Abstract
Background
The incidence of pelvic ring fractures in the elderly significantly increased. Because of persistent pain and immobilization associated with this injury, surgical treatment is recommended. To minimise comorbidities and surgical risk, percutaneous techniques are becoming more relevant. In-screw cement augmentation of sacroiliac screw fixation is a promising procedure; however, clinical follow-up data remain scarce. This study investigated the safety and possible complications of the procedure along with a 1-year follow-up.
Methods
Thirty-four patients (treated with 43 screws) were prospectively included. Data on patients’ age and sex, the mechanism of accident, fracture pattern, duration of hospital stay, surgery and adverse events were recorded. Data were obtained postoperatively on the reduction of pain and complications, such as infection, cement leakage and neurological deficits, and at 1-year follow-up on pain, quality of life according to the 12-Item Short Form Survey and mobility. Implant failure was defined as retraction or dislocation of screws and was also documented.
Results
Screw-related complications occurred with 2 of 43 screws. None of these complications were related to cement augmentation. In-hospital adverse events occurred in 6 of 34 patients. Postoperative pain, measured by the visual analogue scale, was significantly reduced from 6.7 ± 1.4 preoperatively to 2.7 ± 1.0 postoperatively (p < 0.001). Although patients complained of pain at the 1-year follow-up, they reported a significant decline compared with pain at admission (3.4 ± 2.3; p < 0.001). Results on the quality of life were comparable with those for the age- and gender matched German population. All patients were mobile, and no implant failure was detected.
Conclusions
The results indicate that in-screw augmented sacroiliac screw fixation for fragility fractures of the pelvis is a safe technique. Pain was significantly reduced immediately after surgery compared to the preoperative state. Furthermore, significant pain reduction after one year compared to the preoperative state and quality of life was comparable to the age- and gender- matched German population. Thus, we recommend in-screw augmentation for screw fixation for sacral fragility fractures of the pelvis following failed conservative treatment.
Keywords: Fragility fracture, Pelvic fracture, Sacrum fracture, Polymethylmethacrylate, Sacroiliac screw fixation
Background
The incidence of pelvic ring fractures in elderly patients has been increasing because of the ageing of the population [1–4]. In general, these fractures are associated with the combination of a low-energy trauma and an impaired bone stock [5, 6]. The predominant fracture morphology is a lateral compression fracture that involves the anterior pubic rami and an impression of the sacral massa lateralis [7]. Based on the increase of these fractures, Rommens and Hofmann established a new classification system to morphologically describe fragility fractures of the pelvis [8, 9]. Apart from causing pain and related immobilisation, lateral compression injuries have a tendency of becoming unstable during conservative treatment [3, 5, 10]. In addition to appropriate osteoporosis therapy and the use of painkillers, several authors recommend surgical treatment [2, 9, 11, 12].
Because of the high rate of comorbidities, postoperative infections and poor bone quality, percutaneous techniques combined with cement application have become more relevant [13–16]. In-screw cement augmentation with fenestrated screws yielded promising results in short-term follow-up examinations [14, 17]. However, long-term follow-up data remain lacking. The present study investigated pain, quality of life, mobility and implant failure in elderly patients who underwent in-screw polymethylmethacrylate (PMMA) augmented sacroiliac (SI) screw fixation at 1-year follow-up.
Methods
Ethical approval
The study was approved by the local ethics committee (297–12-24,092,012), and informed signed consent was obtained from all participating patients.
Patients, study design and preoperative data acquisition
The present study was carried out from July 2012 to December 2014. The study protocol is presented in Fig. 1. All patients suffering from a transalar fragility fracture of the sacrum classified as AO 61-B2.1, AO 61-B3.3, FFP IIb FFP IIc, FFP IVb or Denis I bilateral (Table 1) [7, 8] were evaluated. Initially all these patients were treated conservatively with physical therapy allowing full weight bearing. Painkillers were given according to the World Health Organization (WHO) analgesic ladder step 2. If mobilization was adequate, conservative treatment was continued (Fig.1). In cases of persistent immobilization surgical treatment was indicated. Patients from this patient population planned for in-screw PMMA augmented SI screw fixation independent of anterior fracture fixation, without additional posterior fixation (e.g. spinopelvic fixation) were asked for study participation and included in the study.
Table 1.
Classification | Fracture type | Number of patients |
---|---|---|
OTA/AO | B 2.1 | 25 |
B 3.3 | 8 | |
Isolated sacral fracture | Denis I bilateral | 1 |
FFP | FFP 2b | 11 |
FFP 2c | 14 | |
FFP 4b | 8 | |
No classification possible | 1 |
Thus, 34 patients (79 ± 8.25 years, 32 female and 2 male) were prospectively included. Nine patients sustained a bilateral Denis I fracture. Furthermore, in cases of unilateral sacral fractures, the corresponding anterior fracture was ipsilateral in 11 patients and contralateral in 10 patients. Four patients had a bilateral anterior fracture. Fracture classifications according to the Orthopaedic Trauma Association/Association for the Study of Internal Fixation (OTA/AO) and Rommens et al. are summarized in Table 1. Baseline data such as age, sex and type of admission, the mechanism of accident, injury pattern and comorbidities are presented in Table 2. Thirty-one patients had a history of minor trauma or no trauma. Eleven patients suffered from additional injuries (5 upper limb fractures, 3 osteoporotic spine fractures and 3 cerebral contusions). Moreover, preoperatively the pain level using the visual analogue scale (VAS) was recorded.
Table 2.
Number of patients | |
---|---|
N | 34 |
Age (years) | 79 ± 8.25 (41–92) |
Gender | 32 females, 2 males; 16:1 |
Admission | 13 primary admission |
21 secondary transfer | |
Comorbiditiesa | 1 with no comorbidities |
24 with ≤ 3 comorbidities | |
9 with > 3 comorbidities | |
Mechanism of accident | 28 fell from a stand |
3 with unknown/no trauma | |
1 because of a traffic accident | |
2 fell from a height of > 3 m | |
Injury pattern | 21 with isolated pelvic ring fracture |
10 with accompanying injuries (ISS < 16) | |
3 with multiple injured (ISS > 16) |
ahypertension, diabetes mellitus, cold, cardiac event in history, neurological event with residual
Surgery- surgical technique, surgical time and amount of used bone cement
With the patient under anaesthesia, the insertion point was determined in lateral sacral fluoroscopic views. All screws were introduced in S1, and the correct course of the threaded K-wire was controlled with fluoroscopic inlet and outlet views [18]. The endpoint was a few millimetres over the sacral midline (Fig. 2a-b).
The screw length was measured using a length gauge over the K-wire. The K-wire was used as a guide, and a cannulated fully threaded 7.5-mm screw (Königsee Implants, Allendorf, Germany) with a washer was introduced. Afterwards, the K-wire was removed, and the bone filler system (Königsee Implants) was applied to inject PMMA (Medtronic, Santa Rosa, CA, USA) under fluoroscopic control. Generally, 3 ml of PMMA was used and spread out on the top and the perforations of the screw (Fig. 2c–e). Data of the surgical procedure including time for surgery, time to surgery, number of screws, additional anterior fixation and the used amount of cement were recorded for further analyses.
Postoperative in-hospital stay – Postoperative pain, duration of hospital stay, adverse events
After surgery, X-rays (anterior-posterior [AP], inlet and outlet) were taken to verify the position of the implant and exclude cement leakage. CTs were indicated if postoperative neurological deficit, suspected cement leakage or thromboembolism was present.
Postoperatively patients were allowed for full weight bearing with the assistance of a physiotherapist. Supporting antiosteoporotic therapy was given or optimized for all patients according to german national guidelines [19]. Postoperative pain, duration of hospital stay, adverse events and pain using the VAS were determined.
One-year follow-up
At the 1-year follow-up (range, 12–14 months), intensity of pain according to the VAS, mobility regarding the usage of orthopaedic aids and quality of life using the 12-Item Short Form Survey (SF-12) were investigated. Radiological examinations were performed in AP, inlet and outlet X-rays to analyse implant positioning and implant failure, which was defined as screw retraction or dislocation.
Data analysis
All data were collected prospectively and retrospectively analysed. Data are presented as mean ± standard deviation or as medians and ranges according to the distribution type. Statistical analyses were performed using the SPSS 20.0 for Windows (SPSS, Chicago, IL, USA); Student t-test and Wilcoxon test were used for analysing data with Gaussian distribution and those with non-Gaussian distribution, respectively. P values of ≤ 0.05 were considered to be statistically significant.
Results
Surgical treatment
The mean time to surgery was 4.5 ± 2.8 days after admission. In 25 cases, unilateral SI screw fixation with in-screw cement augmentation was performed in S1. In one case, fixation of two unilateral screws in S1 was performed, and in eight cases, bilateral SI screw fixation (for a total of 43 SI screws) was performed. The mean surgical time was 27 min per screw, with a range from 17 to 46 min per screw. A mean of 3.0 ± 0.6 ml of bone cement was used for augmentation (Fig. 3a–d).
Anterior stabilisation was performed either by open reduction and plate osteosynthesis (16 patients) or in cases of low displacement, by retrograde percutaneous screw fixation (16 patients). One patient received a retrograde screw on one side and plate osteosynthesis on the other side.
In-hospital stay- hospital stay and adverse events
The mean duration of hospital stay was 14.1 ± 6.1 days (9.6 ± 6.3 days after surgical treatment). Three patients required intensive care monitoring postoperatively. In two patients, revision surgery was necessary because of the PMMA-augmented SI screw fixation. In one patient, one screw was malpositioned and perforated the ventral alar cortical border close to the iliac vessels, as shown by the inlet X-ray views and subsequent CT. In another patient, postoperative hematoma in the gluteal muscle occurred, requiring relief. Thus, complications occurred with 2 of the 43 screws implanted. In three patients, we observed non significant cement leakage into small veins (two patients) or out of the ventral sacral bone (one patient) in postoperative radiological controls, without any therapeutic consequences. No patient had neurological deficits or nerve root compression pain. Additional complications occurred in six patients; urinary tract infections in three, gastrointestinal infection with clostridia in one, pulmonary embolism in one. One patient with a Leriche syndrome not related to pelvic fixation procedure died after bypass surgery related infections 17 days after pelvic ring fracture fixation.
Follow-up
Twenty-eight patients were available for the 1-year follow-up. Five patients were unable to completely fill out the SF-12 because of impaired mental ability. One patient refused to participate in the follow-up. Two patients were lost to follow-up. Including the patient who died during hospitalisation, four patients died within 12 months after surgery. Hence, the data of 23/34 patients were available for analyses involving the follow-up examination.
Quality of life (SF 12) and mobility
The scores for the SF-12, neither for physical and mental state, did not significantly differ from that of the corresponding age- and gender-matched population of Germany (p > 0.05) [20]. The average physical composite score was 35.7 ± 9.1 points, and the average mental composite score was 48.3 ± 11.8 points. These results are graphically shown in Fig. 4 [20]. Nine patients were able to walk without orthopaedic aids after 1 year, six required one or two forearm crutches and 12 were using a walker. No patient was unable to walk.
Pain
The severity of pain at the time of admission was 6.7 ± 1.4 according to the VAS. One day before discharge, the severity of pain reduced to 2.7 ± 1.0 (p < 0.001). The severity of pain was 3.4 ± 2.3 at the 1-year follow-up, which was not significantly different from that on the day of discharge (p > 0.2) (Fig. 5).
Radiological follow-up
X-ray examination found no failures of SI screw fixation in any patient after 1 year.
Discussion
This prospective observational study investigated the clinical safety and 1-year follow-up results of percutaneous implantation of fenestrated SI screws with in-screw PMMA augmentation. The results show that this procedure was safe and had good clinical results, including significant pain reduction, as previously described in a short-term follow-up study in elderly patients [14, 17].
Because of the increasing numbers of fragility fractures of the pelvis, several surgical procedures have been introduced to ensure early ambulation [2–4, 6, 7]. To minimise perioperative risks and comorbidities and reduce operative time in elderly patients, percutaneous techniques have been frequently used [6].
In recent years, several percutaneous techniques have been presented to treat pelvic fractures in elderly patients. For example, the use of sacroplasty led to significant pain reduction and early ambulation but had no biomechanical advantages, as shown by cyclic loadings of cadaver pelves [15, 21, 22]. Nevertheless, fracture healing appears to be impossible after PMMA is added in the fracture gap. In our opinion, the combination of osteosynthesis and a SI screw and PMMA in-screw augmentation might provide more stability and still leave the fracture zone untouched for healing.
Other approaches include the use of a trans-sacral bar, an augmented transiliacal internal fixator or a combination of sacroplasty and SI screw fixation. All techniques have resulted in significant postoperative pain reduction and early mobility; however, they have only been investigated in studies with small sample sizes [16, 23, 24]. This study has also demonstrated a significant postoperative reduction of pain, thereby supporting the results of previous studies regarding in-screw cement augmentation [14, 17].
The short surgical time of 27 min per augmented screw demonstrates that the technique is minimally invasive [25]. Moreover, the rate of complications related to the augmented screws was not higher than that for non-augmented SI screws [25, 26]. None of the complications described here were directly related to the use of PMMA and did not influence the outcome after discharge. Nonetheless, we did not use augmented screws for transforaminal sacral fractures because of a potentially higher risk for leakage of cement into the neuroforamina.
According to previously published reports, we also observed a long hospital stay of approximately 14 days and a high rate of adverse events during the hospital stay [6, 27]. The reported 1-year mortality rate after sacral fragility fractures is up to 27%, which is higher than our rate (4 of 34 patients) [28].
In our previous study we determined a significantly shorter hospital stay in the non-operative group compared to the operative group [29]. Nevertheless, approximately 20% of the non- operative group received surgery due to persistent pain and immobilization. This group most plausible corresponds to the patient population in the here presented study. In the two-year follow up there were no significant differences between all groups in pain level determined using the VAS. Moreover, as observed in the present study the physical state of all patients was lower compared to the age- and gender- adjusted German population but without achieving the level of significance. Compared to conservative treated patients also the hospital stay was shorter following conservative treatment but even shorter compared to other studies [29, 30]. Furthermore, also the complications might not differ between the different treatments and differences in deaths might be resulted from different sample sizes [29, 30].
Although these data might imply a missing superiority of the surgical treatment and especially the need for PMMA augmentation the observed higher survival following surgery might indicate a benefit by the surgical treatment [29]. Indeed, the parameters leading to this difference might be unclear and have to be elucidated. Even still alive the patient’s life might be impaired so that permanent care might be necessary as reported for conservative treatment following a pelvic ring fracture in the elderly [6]. Data for the surgical groups are still missed and should be examined in future studies.
In consideration of these data [6, 29, 30] and the excess of mortality following a pelvic ring fracture in the elderly [31], surgical treatment might be favored especially for patients suffering from persistent pain and immobilization following a conservative treatment [12].
But so far, due to osteoporosis in this patient population the rate of implant failure or backing out of the screws might be increased up to 14% as previously reported [12, 32]. Although the clinical consequence of this backing out is still unknown cement augmentation might be a promising technique to prevent this phenomenon. Thus, sacroiliac cement augmentation was introduced. Indeed, biomechanical examination failed to reveal the superiority of this technique in the hemipelvis model [33–35] the investigation of sole screw-sacral model yielded higher stability using augmented screws [36]. But so far, clinical trials using this technique especially regarding the outcome and pain are still sparse. Therefore, the present study was carried out.
A key finding is the pain reduction after 1 year with achieved mobility, which in our opinion, suggests the healing of the fracture. Without any proof, we assume reasons for the increasing distribution of the pain level after 1 year compared to discharge are co-morbidities (e.g. arthrosis, degenerative changes of the spinal column) and reduced or stopped analgesic therapy. Furthermore, the quality of life in this study population was not significantly different compared with that in the age- and gender- matched German population [20]. Moreover, in the present study no implant failure or subsequent pelvic ring fracture was observed. Regarding mobility there was no patient unable to walk suggesting also a minor amount of patients requiring permanent care.
Nonetheless, this study has some limitations. Although the study design was prospective, the rate of loss to follow-up was high. Different methods of osteosynthesis of the anterior pelvic ring might have influenced the clinical course. Because of the need for protection from radiation, not all patients underwent postoperative CT. One substantial limitation is the missed control group to compare the presented results.
Conclusion
In-screw PMMA augmentation of fenestrated SI screws is a safe technique with a short surgical time leading to pain reduction. Follow- up data suggests non-significant differences to the age- and gender-adjusted German population and no implant failure occurred. Although the superiority of this technique compared to conservative treatment or other surgical opportunities is not examined the presented procedure might be suitable after failed conservative treatment of fragility fractures of the sacrum.
Acknowledgements
We acknowledge support from the German Research Foundation (DFG) and Leipzig University within the program of Open Access Publishing.
Funding
Within the program of Open Access Publishing the DFG and University of Leipzig pay the publication fee for this article. The founding sponsors had no role in the design of the study, in the collection, analyses, or interpretation of data or in the writing of the manuscript, and in the decision to publish the results.
Availability of data and materials
Raw and analysed data are available from the corresponding author on reasonable request.
Abbreviations
- AP
anterior-posterior
- CT
computer tomographie
- OTA/AO
Orthopaedic Trauma Association/Association for the Study of Internal Fixation
- PMMA
polymethylmethacrylate
- SF-12
12-Item Short Form Survey
- SI
sacroiliac
- VAS
visual analogue scale
Authors’ contributions
AH, PP and JB drafted the protocol and edited the study design. JB lead the project group, JC and RH provided critical review of the manuscript and gave advisory for improvement. AH and PP wrote the manuscript. All authors read and approved the final manuscript.
Ethical approval and consent to participate
Ethical approval was obtained from the local ethics committee of the University of Leipzig (297–12-24,092,012) and, informed signed consent was obtained from all participating patients of the present study. Copies of the written consents are available for review by the editor of this journal.
Consent for publication
Not applicable.
Competing interests
Dr. Jörg Böhme has currently an advisory contract with Königsee Implants (Allendorf, Germany). All other authors declare that they have no conflict of interest.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Andreas Höch, Phone: +493419717843, Email: andreas.hoech@medizin.uni-leipzig.de.
Philipp Pieroh, Email: philipp.pieroh@medizin.uni-leipzig.de.
Ralf Henkelmann, Email: ralf.henkelmann@medizin.uni-leipzig.de.
Christoph Josten, Email: Christoph.josten@medizin.uni-leipzig.de.
Jörg Böhme, Email: joerg.boehme@sanktgeorg.de.
References
- 1.Kannus P, Niemi S, Parkkari J, Palvanen M, Vuori I, Järvinen M. Nationwide decline in incidence of hip fracture. J Bone Miner Res. 2006;21:1836–1838. doi: 10.1359/jbmr.060815. [DOI] [PubMed] [Google Scholar]
- 2.Buller LT. Best MJ, Quinnan SM. A Nationwide analysis of pelvic ring fractures: incidence and trends in treatment, length of stay, and mortality. Geriatr Orthop Surg Rehabil. 2016;7:9–17. doi: 10.1177/2151458515616250. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Breuil V, Roux CH, Carle GF. Pelvic fractures: epidemiology, consequences, and medical management. Curr Opin Rheumatol. 2016;28:442–447. doi: 10.1097/BOR.0000000000000293. [DOI] [PubMed] [Google Scholar]
- 4.Andrich S, Haastert B, Neuhaus E, Neidert K, Arend W, Ohmann C, et al. Epidemiology of pelvic fractures in Germany: considerably high incidence rates among older people. PLoS One. 2015;10:e0139078. doi: 10.1371/journal.pone.0139078. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.O'Connor TJ, Cole PA. Pelvic insufficiency fractures. Geriatr Orthop Surg Rehabil. 2014;5:178–190. doi: 10.1177/2151458514548895. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Maier GS, Kolbow K, Lazovic D, Horas K, Roth KE, Seeger JB, Maus U. Risk factors for pelvic insufficiency fractures and outcome after conservative therapy. Arch Gerontol Geriatr. 2016;67:80–85. doi: 10.1016/j.archger.2016.06.020. [DOI] [PubMed] [Google Scholar]
- 7.Böhme J, Höch A, Boldt A, Josten C, Einfluss d. Standard-Computertomografie hinsichtlich Frakturklassifikation und Therapie von Beckenringfrakturen bei Patienten über dem 65. Lebensjahr. Z Orthop Unfall. 2012;150:477–483. doi: 10.1055/s-0032-1315270. [DOI] [PubMed] [Google Scholar]
- 8.Rommens PM, Hofmann A. Comprehensive classification of fragility fractures of the pelvic ring: recommendations for surgical treatment. Injury. 2013;44:1733–1744. doi: 10.1016/j.injury.2013.06.023. [DOI] [PubMed] [Google Scholar]
- 9.Arduini M, Saturnino L, Piperno A, Iundusi R, Tarantino U. Fragility fractures of the pelvis: treatment and preliminary results. Aging Clin Exp Res. 2015;27(Suppl 1):S61–S67. doi: 10.1007/s40520-015-0430-4. [DOI] [PubMed] [Google Scholar]
- 10.Rommens PM, Ossendorf C, Pairon P, Dietz S-O, Wagner D, Hofmann A. Clinical pathways for fragility fractures of the pelvic ring: personal experience and review of the literature. J Orthop Sci. 2015;20:1–11. doi: 10.1007/s00776-014-0653-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Hegde V, Jo JE, Andreopoulou P, Lane JM. Effect of osteoporosis medications on fracture healing. Osteoporos Int. 2016;27:861–871. doi: 10.1007/s00198-015-3331-7. [DOI] [PubMed] [Google Scholar]
- 12.Wagner D, Ossendorf C, Gruszka D, Hofmann A, Rommens PM. Fragility fractures of the sacrum: how to identify and when to treat surgically? Eur J Trauma Emerg Surg. 2015;41:349–362. doi: 10.1007/s00068-015-0530-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Tjardes T, Paffrath T, Baethis H, Shafizadeh S, Steinhausen E, Steinbuechel T, et al. Computer assisted percutaneous placement of augmented iliosacral screws: a reasonable alternative to sacroplasty. Spine. 2008;33:1497–1500. doi: 10.1097/BRS.0b013e318175c25c. [DOI] [PubMed] [Google Scholar]
- 14.Wähnert D, Raschke MJ, Fuchs T. Cement augmentation of the navigated iliosacral screw in the treatment of insufficiency fractures of the sacrum: a new method using modified implants. Int Orthop. 2013;37:1147–1150. doi: 10.1007/s00264-013-1875-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Garant M. Sacroplasty: a new treatment for sacral insufficiency fracture. J Vasc Interv Radiol. 2002;13:1265–1267. doi: 10.1016/S1051-0443(07)61976-9. [DOI] [PubMed] [Google Scholar]
- 16.Mehling I, Hessmann MH, Rommens PM. Stabilization of fatigue fractures of the dorsal pelvis with a trans-sacral bar. Operative technique and outcome. Injury. 2012;43:446–451. doi: 10.1016/j.injury.2011.08.005. [DOI] [PubMed] [Google Scholar]
- 17.König MA, Hediger S, Schmitt JW, Jentzsch T, Sprengel K, Werner CML. In-screw cement augmentation for iliosacral screw fixation in posterior ring pathologies with insufficient bone stock. Eur J Trauma Emerg Surg. 2016;25:378. doi: 10.1007/s00068-016-0681-6. [DOI] [PubMed] [Google Scholar]
- 18.Herman A, Keener E, Dubose C, Lowe JA. Simple mathematical model of sacroiliac screws safe-zone-easy to implement by pelvic inlet and outlet views. J Orthop Res. 2017;35:1478–1484. doi: 10.1002/jor.23396. [DOI] [PubMed] [Google Scholar]
- 19.DVO Guidelines for the prevention, diagnosis and therapy of osteoporosis in postmenopausal women and men aged 60 and over. 2014. www.dv-osteologie.org/dvo_leitlinien/osteoporose-leitlinie-2014. Accessed 13 January 2017.
- 20.Ellert U, Bellach BM. The SF-36 in the Federal Health Survey--Description of a current normal sample. Gesundheitswesen. 1999;61:S184–S190. [PubMed] [Google Scholar]
- 21.Kortman K, Ortiz O, Miller T, Brook A, Tutton S, Mathis J, Georgy B. Multicenter study to assess the efficacy and safety of sacroplasty in patients with osteoporotic sacral insufficiency fractures or pathologic sacral lesions. J Neurointerv Surg. 2013;5:461–466. doi: 10.1136/neurintsurg-2012-010347. [DOI] [PubMed] [Google Scholar]
- 22.Mears SC, Sutter EG, Wall SJ, Rose DM, Belkoff SM. Biomechanical comparison of three methods of sacral fracture fixation in osteoporotic bone. Spine. 2010;35:E392–E395. doi: 10.1097/BRS.0b013e3181cb4fcd. [DOI] [PubMed] [Google Scholar]
- 23.Schmitz P, Baumann F, Grechenig S, Gaensslen A, Nerlich M, Müller MB. The cement-augmented transiliacal internal fixator (caTIFI): an innovative surgical technique for stabilization of fragility fractures of the pelvis. Injury. 2015;46(Suppl 4):S114–S120. doi: 10.1016/S0020-1383(15)30029-2. [DOI] [PubMed] [Google Scholar]
- 24.Collinge CA, Crist BD. Combined Percutaneous Iliosacral screw fixation with Sacroplasty using Resorbable calcium phosphate cement for osteoporotic pelvic fractures requiring surgery. J Orthop Trauma. 2016;30:e217–e222. doi: 10.1097/00005131-201606000-00016. [DOI] [PubMed] [Google Scholar]
- 25.Stöckle U, Schaser K, König B. Image guidance in pelvic and acetabular surgery--expectations, success and limitations. Injury. 2007;38:450–462. doi: 10.1016/j.injury.2007.01.024. [DOI] [PubMed] [Google Scholar]
- 26.Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133:1257–1265. doi: 10.1007/s00402-013-1788-4. [DOI] [PubMed] [Google Scholar]
- 27.Taillandier J, Langue F, Alemanni M, Taillandier-Heriche E. Mortality and functional outcomes of pelvic insufficiency fractures in older patients. Joint Bone Spine. 2003;70:287–289. doi: 10.1016/S1297-319X(03)00015-0. [DOI] [PubMed] [Google Scholar]
- 28.Morris RO, Sonibare A, Green DJ, Masud T. Closed pelvic fractures: characteristics and outcomes in older patients admitted to medical and geriatric wards. Postgrad Med J. 2000;76:646–650. doi: 10.1136/pmj.76.900.646. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Höch A, Özkurtul O, Pieroh P, Josten C, Böhme J. Outcome and 2-year survival rate in elderly patients with lateral compression fractures of the pelvis. Geriatr Orthop Surg Rehabil. 2017;8:3–9. doi: 10.1177/2151458516681142. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Kanakaris NK, Greven T, West RM, van Vugt AB, Giannoudis PV. Implementation of a standardized protocol to manage elderly patients with low energy pelvic fractures: can service improvement be expected? Int Orthop. 2017;41:1813. [DOI] [PubMed]
- 31.Andrich S, Haastert B, Neuhaus E, Neidert K, Arend W, Ohmann C, et al. Excess mortality after pelvic fractures among older people. J Bone Miner Res. 2017;32:1789–1801. doi: 10.1002/jbmr.3116. [DOI] [PubMed] [Google Scholar]
- 32.Reuther G, Röhner U, Will T, Dehne I, Petereit U. CT-guided screw fixation of vertical sacral fractures in local anaesthesia using a standard CT. Rofo. 2014;186:1134–1139. doi: 10.1055/s-0034-1366605. [DOI] [PubMed] [Google Scholar]
- 33.Osterhoff G, Dodd AE, Unno F, Wong A, Amiri S, Lefaivre KA, Guy P. Cement augmentation in sacroiliac screw fixation offers modest biomechanical advantages in a cadaver model. Clin Orthop Relat Res. 2016;474:2522–2530. doi: 10.1007/s11999-016-4934-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Höch A, Schimpf R, Hammer N, Schleifenbaum S, Werner M, Josten C, Böhme J. Biomechanical analysis of stiffness and fracture displacement after using PMMA-augmented sacroiliac screw fixation for sacrum fractures. Biomed Tech (Berl) 2017;62:421–428. doi: 10.1515/bmt-2016-0235. [DOI] [PubMed] [Google Scholar]
- 35.Grüneweller N, Raschke MJ, Zderic I, Widmer D, Wähnert D, Gueorguiev B, et al. Biomechanical comparison of augmented versus non-augmented sacroiliac screws in a novel hemi-pelvis test model. J Orthop Res. 2017;35:1485–1493. doi: 10.1002/jor.23401. [DOI] [PubMed] [Google Scholar]
- 36.Oberkircher L, Masaeli A, Bliemel C, Debus F, Ruchholtz S, Krüger A. Primary stability of three different iliosacral screw fixation techniques in osteoporotic cadaver specimens-a biomechanical investigation. Spine J. 2016;16:226–232. doi: 10.1016/j.spinee.2015.08.016. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Raw and analysed data are available from the corresponding author on reasonable request.