Abstract
A novel liquid crystal microlens array with tunable multifocal capability, high optical power and fill-factor is proposed and experimentally demonstrated. A specific hole pattern design produces a multifocal array with only one voltage control. Three operations modes are possible, “Off”, “Tunable Multifocal” and “Unifocal”. The design is patterned in both substrates. Then, the substrates are arranged in symmetrical configuration. The result is a high optical power in comparison with typical hole patterned structures. Besides, it is proposed a hexagonal pattern that produces a high fill factor, specially indicated for some applications as Integral Imaging. The array has several useful characteristics for this type of application: tunability for the loss of resolution; multifocal for extended DOF; high fill factor for increase the number of views; and low power consumption for integration in portable devices. Moreover, the optical characteristics of the proposed device could bring new applications in other fields.
Introduction
Research on liquid crystal (LC) lenses has gained an increasing interest in recent years. The low-weight, tunable focus, low power consumption and broad range of applications makes them unique with respect to other technologies. Since the first LC lens was proposed by Berreman et al.1 and Sato et al.2 several decades ago, a lot of different structures have came up. Some of the most important are, patterned electrodes3,4 Fresnel lenses5, modal control6,7 and immersed microlenses8. Another option is to modify the LC mixture itself. For example, polymer networks9, concentration redistribution10, carbon nanotubes11, blue-phase LC12, dual frequency LC13, tunable frequency14. This last option, is used to improve the switching time of the LC. Polymer networks and blue phases (a special cholesteric LC phase), have microsecond response time but the optical phase modulation is very limited. Dual frequency and tunable frequency improve both characteristics. Some recent applications of LC lenses include, auto-focusing systems and optical zoom systems15, pico-projection systems16, correction of defects in holographic projection systems17, photovoltaics18 or bio-optics (endoscopy19, ophthalmology20,21). Another important application is also 3D vision22. The research on LC lenses for autostereoscopic vision has produced several interesting results23. Liquid crystal lenses can be used as a replacement of conventional arrays in spatial multiplexing technique. This technique is based on classical optical phenomena as diffraction, reflection, refraction and occlusion in order to deviate the images to different positions in front of the display. Several technologies to produce this effect have been proposed. Among them, occlusive and refractive elements are the most used. Occlusive elements usually consists on masks containing vertical apertures that cover the light at certain angles. On the other hand, refractive elements are based on microlenses, with the advantage of more brightness, view angle and less crosstalk (depending on the microlens quality). These techniques, which are already used in commercial products, have not produced enough interest in the users. Some reasons are the reduced 3D content, low qualities (producing crosstalk) and the key problem of vergence-accommodation conflict (the adjustment of the eye focus). In order to avoid this problem, several solutions have been proposed. For example, increase the number of views or use full parallax (multi-view24 or Integral Imaging25). Integral imaging (InI) have both characteristics, several views and full parallax, making it the most promising technology for autostereoscopic displays and cameras. Gabriel M. Lippmann proposed this technique in 1908. He used an array of microlenses to collect the scene information in several tiny versions of the same one, each one with a different angle and position (similar to have a sampled hologram). The scene can be reproduced by using also microlenses, in this case the reproduction have full parallax and the cue of accommodation. This makes the system one of the best solutions to reproduce 3D images without visual strain and fatigue. Thanks to current developments on microlens manufacturing, this technique has been exploited recently with the commercialization of the first plenoptic camera26. These types of cameras have several advantages e.g. rendering images of several views, digital refocusing, depth estimation, 3D reconstruction, etc. Despite this, the use of fixed microlenses has several limitations due to the lack of tuning. In the literature, is possible to find several proposals to solve these problems, for example an extended Depth of Field (DOF) was proposed in27 by using a multifocal fixed lens. For the loss of resolution, switchable LC lenses were proposed in28. The DOF has been demonstrated to be tunable in29 and30. In31 LC microlenses were proposed in order to increase the viewing angle or field of view (FOV).
In this work, a novel tunable multifocal microlens array is proposed and experimentally demonstrated. The tunability is based on the properties of LC materials. Three operations modes are possible, OFF, tunable multifocal and unifocal. These modes can be controlled with only one low voltage signal. Among others, one possible application could be InI. The array has several useful characteristics for this type of application: tunability for the loss of resolution; multifocal for extended DOF; high fill factor for increase the number of views; and low power consumption for integration in portable devices. Moreover, the optical characteristics of this device could bring new applications in other fields
Design and Structure
Conventional lenses have two physical characteristics that modify a wavefront trough them, the contrast between the refractive index of the lens and the surrounding medium, and the curvature of the interface between them. In the case of LC lenses, the medium is non-homogeneous, in consequence the wavefronts decrease its speed in the optically dense regions and are accelerated in areas of lower density. Because LC lenses are actually GRaded Index (GRIN) lenses, the estimation of the focal length, fGRIN, of the LC lenses is simple if the focusing of parallel rays is considered (Eq. 1),
1 |
where R is the lens radius (half lens pitch), t is the thickness of the lens (thickness of the LC layer) and n max − n(r) is the difference between the maximum refractive index, n max (at the optical axis of each lens) and the refractive index at the position r (that is, at the edge of the lens). In order to change the focal length, two structural parameters can be modified, the radius and the thickness. In this work, several focal lenghts are created by varying the radius of each microlens. If more contrast ratio between focal lengths would be required, the thickness could be also modified (by depositing photoresist of different thicknesses).
Symmetrical electrodes are used in order to increase the optical power, for this reason, special mask patterns have to be designed. Each square of the mask device is patterned with a specific motif (see Fig. 1),
The fabrication process requires a precise alignment of both upper and bottom substrates. Motifs of Fig. 1 allow alignments in the limit of the mask aligner. A mask aligner MA/BA6 Mask and Bond Aligner have been used. The MA/BA6 is equipped with a motorized top side alignment system that can reach an alignment accuracy of ± 0.5 µm. To reduce diffraction effects at the edge of the structured patterns, contact mode is used. In this process, the mask and the wafer are pressed all together. The same mask aligner has been used to align the top and the bottom hexagonal pattern before assembly the microlens device. Two ITO coated substrates (20 Ω/sq) with hexagonal electrodes patterned in each one Fig. 2(a) are prepared. This hexagonal aperture produces the hexagonal type microlenses. A polyimide (PIA2000) is deposited over the two substrates to have certain molecular alignment. Spacers of 40 µm diameter, mixed with optical glue, are deposited to separate the two substrates. Finally, a LC (E7) fills the cavity. The electro-optical parameters are: ne = 1.7305; no = 1.5189 (Δn = 0.2116 at 633 nm, 25 °C)32. The diameters of the hexagons range from 120 to 90 µm in steps of 10 µm. The total active area of the array is 2.13 cm width and 1.42 cm height.
In order to have a high fill factor, microlenses with hexagonal apertures are designed. This allows a considerably reduction of the space between them. The symmetrical configuration produces a high optical power as it is demonstrated in the results. In comparison with typical hole lenses with the same aperture and thickness, the optical power is doubled. The use of symmetrical electrodes avoid the negative effect of a continuous ground electrode. When one substrate have 0 volts, the voltage distribution in most part of the LC material is below threshold voltage. For this reason, in asymmetrical configuration an insufficient use of the LC birefringence is made. The symmetrical electrodes produce voltages above the threshold voltage in the center of the microlenses. Thanks to this effect, the molecules are switched on in this region producing higher birefringence differences. In consequence, the phase difference with a symmetrical configuration is considerable higher. The main advantage of the proposed device is that only one voltage source is required. Moreover, low voltage signals are enough to switch the microlenses. Extended results are described in the next section.
Experimental set-up and Results
In order to demonstrate the homogeneity and the fill factor of the whole sample, Fig. 3 shows the switched sample by using a polarized microscope (x5 objective) and Fig. 4a comparison between the use of circular and hexagonal apertures.
The homogeneity of the sample is clearly stated. The fill factor is higher in the hexagonal pattern as the spaces between circles is avoided. The multifocal property can be observed through the different spot sizes. View that is more detailed is obtained through the fringe patterns. For this experiment, the system is placed in an optical table. The experimental set-up consists of: a He-Ne laser source (632.8 nm), a neutral density filter, a LC sample between crossed polarizers, a × 10 microscope objective and a B/W CCD digital camera (effective no. of pixels 1344 × 1024).
Figure 5 shows the experimental fringe patterns of the proposed device for several applied voltages. Every two bright fringes means an optical phase difference of 2π between them. Thanks to this, the phase profile and the focal length can be extracted from these results33. As can be observed, the lower the voltage the lower the number of fringes. This means that low optical power is obtained, generating a higher focal distance. From these observations three operations modes are expected. If the voltage do not reach 1.2 VRMS, the molecules are below threshold voltage and parallel to the substrate, in consequence there is not birefringence difference from the side to the center of the microlenses. This would be the “Off” mode. When the voltage is increased, the molecules start to switch in the sides, remaining parallel to the substrate in the center, and then the fringe patterns appear. Until 2.6 VRMS the number of fringes is almost the same for the four type of microlens, 120 µm (A), 110 µm (B), 100 µm (C) and 90 µm (D). In this case, as the only parameter of Eq. 1 that changes is r, the focal distance changes in quadratic proportion. A multifocal tunable lens is obtained in this range (“Tunable Multifocal” mode). Moreover, the aperture is almost circular (see Fig. 4b and c). The elastic forces for these voltages are relatively low, the molecules have a smooth directional transition between them so the hexagonal aperture is almost circular. The last tunable range can be considered above 2.6 VRMS, two combined physical effects makes the lenses (A, B, C, D) to have the same focal length. Despite the radius is different, the number of fringes is also different. In this case, there is a limit of the maximum phase profile that can be obtained related to the ratio between the radius and thickness of the LC microlens34. The higher the radius the higher the birefringence difference. Both terms are offset against each other in Eq. 1, The result is a similar focal length in each microlens (“Unifocal” mode). In order to observe these effects, the focal length of each microlens for several voltages is plotted in Fig. 6.
As it was observed in the fringe patterns, there is a modulation region between the threshold voltage and 2.4 VRMS (“Tunable Multifocal” mode). The maximum focal length ratio is 56% for 1.4 VRMS, with a focal length ranging from 948 µm to 533 µm. For voltages above 2.6 VRMS the focal length, converge around 300 µm (“Unifocal” mode). As commented before, despite the radius is different, the number of fringes is also different so both terms compensate each other in Eq. 1.
In31 it was demonstrated a control of the FOV and the Multiview image processing with LC lenses. In this case, this mulifocal lens array would be capable of the DOF control with the added advantage of extension of the same one27. In addition, full resolution can be obtained in the OFF mode.
Conclusions
A novel LC microlens array with multifocal capability, high optical power and almost full fill-factor has been proposed and experimentally demonstrated. The combination of a specific hole pattern design produces a multifocal array with only one voltage control. Three operations modes are possible, OFF, tunable multifocal and unifocal. Symmetrical electrodes are used. The result is a high optical power in comparison with typical hole patterned structures. Besides, it is proposed a hexagonal pattern that produces a high fill factor, specially indicated for some applications as Integral Imaging. The array has several useful characteristics for this type of application, tunability for the loss of resolution, multifocal for extended DOF, high fill factor for increase the number of views, and low power consumption for integration in portable devices. Moreover, the optical characteristics of this novel device could bring novel applications in other fields.
Acknowledgements
This work was supported by the Research and Development Program through the Comunidad de Madrid (SINFOTON S2013/MIT-2790), the Ministerio de Economía y Competitividad of Spain (TEC2013-47342-C2-2-R) and the funding from Agencia Estatal de Investigación (AEI) and Fondo Europeo de Desarrollo Regional (FEDER) for the Project TEC2016-77242-C3-1-R AEI/FEDER,UE. Finally, N. Bennis, P. Morawiak and L. R. Jaroszewicz, thank the Polish Ministry of Science and Higher Education (Statutory Activity PBS-654 of Military University of Technology).
Author Contributions
J.F. Algorri and N. Bennis designed the device and the electrical waveforms. N. Bennis and P. Morawiak fabricated the device. J.F. Algorri, V. Urruchi and N. Bennis analyzed the data, wrote the main manuscript text and prepared the figures. J.M. Pena and L.R. Jaroszewicz supervised the work.
Competing Interests
The authors declare that they have no competing interests.
Footnotes
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Berreman, D. W. Variable-focus LC-lens system. Bell Telephone Laboratories, United States patent US 4190330 (1980).
- 2.Sato S. Liquid-crystal lens-cells with variable focal length. Jpn. J. Appl. Phys. 1979;18:1679–1684. doi: 10.1143/JJAP.18.1679. [DOI] [Google Scholar]
- 3.Nose T, Sato S. A liquid crystal microlens obtained with a non-uniform electric field. Liq. Cryst. 1989;5:1425–1433. doi: 10.1080/02678298908027780. [DOI] [Google Scholar]
- 4.Algorri JF, Urruchi V, Bennis N, Sánchez-Pena JM, Otón JM. Cylindrical Liquid Crystal Microlens Array with Rotary Optical Power and Tunable Focal Length. IEEE Elect. Dev. Lett. 2015;36:582–584. doi: 10.1109/LED.2015.2419511. [DOI] [Google Scholar]
- 5.Williams, G., Powell, N., Purvis, A. & Clark, M. G. Electrically controllable liquid crystal fresnel lens. In Opto-electronics Symposium SPIE 1168 (1989).
- 6.Love GD, Naumov AF. Modal liquid crystal lenses. Liq. Cryst. Today. 2000;10:1–4. doi: 10.1080/135831401750061465. [DOI] [Google Scholar]
- 7.Loktev MY, et al. Wave front control systems based on modal liquid crystal lenses. Rev. Sci. Instrum. 2000;71:3290–3297. doi: 10.1063/1.1288256. [DOI] [Google Scholar]
- 8.Dai HT, Liu YJ, Sun XW, Luo D. A negative-positive tunable liquid-crystal microlens array by printing. Opt. Express. 2009;17:4317–4323. doi: 10.1364/OE.17.004317. [DOI] [PubMed] [Google Scholar]
- 9.Ren H, Wu S-T. Tunable electronic lens using a gradient polymer network liquid crystal. Applied Physics Letters. 2003;82:22. doi: 10.1063/1.1534915. [DOI] [Google Scholar]
- 10.Ren H, Lin Y-H, Wu S-T. Adaptive lens using liquid crystal concentration redistribution. Applied Physics Letters. 2006;88:191116. doi: 10.1063/1.2202727. [DOI] [Google Scholar]
- 11.Rajasekharan R, et al. Optimization of nanotube electrode geometry in a liquid crystal media from wavefront aberrations. Applied Optics. 2012;51:422. doi: 10.1364/AO.51.000422. [DOI] [PubMed] [Google Scholar]
- 12.Lin S-H, Huang L-S, Lin C-H, Kuo C-T. Polarizer-free and fast response microlens arrays using polymer-stabilized blue phase liquid crystals. Applied Physics Letters. 2010;96:113505. doi: 10.1063/1.3360860. [DOI] [Google Scholar]
- 13.Xianyu, H., Wu, S.-T. & Lin, C.-L. Dual frequency liquid crystals: a review. Liquid Crystals36, (2009).
- 14.Algorri JF, et al. Low aberration and fast switching microlenses based on a novel liquid crystal mixture. Opt. Express. 2017;25:14795–14808. doi: 10.1364/OE.25.014795. [DOI] [PubMed] [Google Scholar]
- 15.Ye M, et al. Focus tuning by liquid crystal lens in imaging system. Appl. Opt. 2012;51:7630–5. doi: 10.1364/AO.51.007630. [DOI] [PubMed] [Google Scholar]
- 16.Lin Y-H, Chen M-S. A pico projection system with electrically tunable optical zoom ratio adopting two liquid crystal lenses. J. Disp. Technol. 2012;8:401–404. doi: 10.1109/JDT.2012.2185215. [DOI] [Google Scholar]
- 17.Lin H-C, Collings N, Chen M-S, Lin Y-H. A holographic projection system with an electrically tuning and continuously adjustable optical zoom. Opt. Express. 2012;20:27222–9. doi: 10.1364/OE.20.027222. [DOI] [PubMed] [Google Scholar]
- 18.Tsou Y-S, Chang K-H, Lin Y-H. A droplet manipulation on a liquid crystal and polymer composite film as a concentrator and a sun tracker for a concentrating photovoltaic system. J. Appl. Phys. 2013;113:244504. doi: 10.1063/1.4812391. [DOI] [Google Scholar]
- 19.Hassanfiroozi A, Huang Y-P, Javidi B, Shieh H-PD. Hexagonal liquid crystal lens array for 3D endoscopy. Opt. Express. 2015;23:971–81. doi: 10.1364/OE.23.000971. [DOI] [PubMed] [Google Scholar]
- 20.Pixeloptics, Adjustable electro-active optical system and uses thereof. US patent 20140204333 A1 (2014).
- 21.Lin Y-H, Chen H-S. Electrically tunable-focusing and polarizer-free liquid crystal lenses for ophthalmic applications. Opt. Express. 2013;21:9428–36. doi: 10.1364/OE.21.009428. [DOI] [PubMed] [Google Scholar]
- 22.Algorri JF, Urruchi V, Sánchez-Pena JM, Otón JM. An Autostereoscopic Device for Mobile Applications Based on a Liquid Crystal Microlens Array and an OLED Display. J. Disp. Technol. 2014;46:327–336. [Google Scholar]
- 23.Algorri JF, Urruchi V, García-Cámara B, Sánchez-Pena JM. Liquid crystal microlenses for autostereoscopic displays. Materials. 2016;9:1–17. doi: 10.3390/ma9010036. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Dodgson NA. Optical devices: 3D without the glasses. Nature. 2013;495:316–7. doi: 10.1038/495316a. [DOI] [PubMed] [Google Scholar]
- 25.Xiao X, Javidi B, Martinez-Corral M, Stern A. Advances in three-dimensional integral imaging: sensing, display, and applications. Appl. Opt. 2013;52:546–60. doi: 10.1364/AO.52.000546. [DOI] [PubMed] [Google Scholar]
- 26.Adelson EH, Wang JYA. Single Lens Stereo with Plenoptic Camera. IEEE Transactions on Pattern Analysis and Machine Intelligence. 1992;14(2):99–106. doi: 10.1109/34.121783. [DOI] [Google Scholar]
- 27.Georgiev, T. G. Plenoptic camera with large depth of field. US 7949252 B1 (2011).
- 28.Kwon H, et al. A Gradient Index Liquid Crystal Microlens Array for Light-Field Camera Applications. Phot. Techn. Lett. 2015;27:836–839. doi: 10.1109/LPT.2015.2393875. [DOI] [Google Scholar]
- 29.Lei Y, et al. An electrically tunable plenoptic camera using a liquid crystal microlens array. Rev. Sci. Inst. 2015;86:053101. doi: 10.1063/1.4921194. [DOI] [PubMed] [Google Scholar]
- 30.Shen X, et al. Extended depth-of-focus 3D micro integral imaging display using a bifocal liquid crystal lens. Opt. Lett. 2015;40:538–541. doi: 10.1364/OL.40.000538. [DOI] [PubMed] [Google Scholar]
- 31.Algorri JF, et al. Integral imaging capture system with tunable field of view based on liquid crystal microlenses. IEEE Photon. Technol. Lett. 2016;28:1854–1857. doi: 10.1109/LPT.2016.2572258. [DOI] [Google Scholar]
- 32.Li J, Wen C-H, Gauza S, Lu R, Wu S-T. Refractive indices of liquid crystals for display applications. Journal of Display Technology. 2005;1:51–61. doi: 10.1109/JDT.2005.853357. [DOI] [Google Scholar]
- 33.Urruchi V, et al. Lenticular Arrays Based on Liquid Crystals. Opto-electron. Rev. 2012;20(3):38–44. [Google Scholar]
- 34.Algorri JF, Urruchi V, Bennis N, Sánchez-Pena JM. Using an Analytical Model to Design Liquid Crystal Microlenses. IEEE Photon. Technol. Lett. 2014;26(8):793–796. doi: 10.1109/LPT.2014.2306920. [DOI] [Google Scholar]