Background
In critical care units, the shelf for cardiac output (CO) monitoring devices fills up with ever more innovative systems. Are these techniques useful, or are they expensive and irrelevant gadgets? There are arguments to defend both viewpoints. In this commentary, which we have drawn up as a ‘pro–con debate’, we expose these arguments and deliver our opinion.
Throw it out!
During circulatory failure, the variable that really matters is not CO but oxygen delivery and ultimately tissue oxygenation. However, a given value of CO does not necessarily inform on tissue oxygenation. Firstly, CO depends much on global oxygen demand; thus an apparently high CO may be inadequate (high oxygen demand), whereas a low CO might perfectly fit requirements (low oxygen demand). Secondly, CO is not the only determinant of oxygen delivery. For instance, even if fluid increases CO, the oxygen delivery to the tissues may increase to a smaller extent due to the inherent haemodilution [1]. Assessing global tissue oxygenation, through clinical examination, lactate, and central venous oxygenation (ScvO2), should be much more relevant than monitoring CO. Thirdly, tissue oxygen supply primarily depends on microcirculation. Under physiological conditions, CO and microcirculatory flows are coupled. However, in some circumstances, the most typical being sepsis, the regulation of microcirculatory flows is impaired and “coherence” between the macro- and microcirculation is lost [2]. In this regard, increasing CO cannot guarantee any parallel correction of microcirculatory abnormalities [3]. As an illustration, a clinical study showed that oxygen consumption improves in only half of patients in whom fluid infusion increases CO [1]. When deciding to continue fluid infusion or not, are not effects on tissue oxygenation more important than CO?
To justify its monitoring, CO should at least be a target for haemodynamic resuscitation which, unlike arterial pressure, is not actually the case. Also, the arterial pulse pressure is physiologically related to stroke volume. Rather than using costly and often invasive CO monitoring, could we not simply measure arterial pressure along with the above-mentioned tissue oxygenation variables?
Finally, studies repeatedly show that using CO monitoring devices during shock does not improve outcome [4]. All these arguments may discourage us from monitoring CO in critically ill patients…
… but should we really?
The absence of any demonstrated benefit of haemodynamic monitoring is not a definitive argument. Nobody would administer norepinephrine without monitoring its effects on arterial pressure. Then, why should we use treatments aimed at increasing CO without directly checking their efficacy? Shock is so a complex disease that it is illusory that monitoring one single light on the dashboard can change prognosis. What may influence prognosis is not the monitoring, but the therapeutic decisions inferred from it. Odds are that this will never be properly demonstrated by any randomised trial, since a protocol taking into account all alternatives is impossible to establish.
Though oxygen delivery matters, CO is its main determinant and, often, the only lever one can operate to increase it. If CO should not be monitored on the pretext that only oxygen delivery matters, haemoglobin should not be measured after red blood cell transfusion.
Tailoring the treatment to the individual patient is a goal to reach, particularly for reducing harm due to therapy. Nevertheless, CO is highly variable depending on the type of shock, on the patient, and on the timing. For instance, the effects of volume expansion are not only variable among patients, but also transient [5]. This variability spurs CO measurement. Directly monitoring it is the unique way to do so since its clinical estimation is not reliable. In 530 patients, the presence of one clinical criterion among lengthening of capillary filling time, knees mottling, and cold extremities was totally inaccurate to detect a low CO [6]. Not only is there no “normal” value of CO, but also a high value of CO might co-exist with such signs of hypoperfusion.
Those who are reluctant to monitor CO often argue that monitoring arterial pressure is more than sufficient. Arterial pressure, which determines organ perfusion, is a relevant therapeutic target, but CO, which determines oxygen delivery, is no less vital. Moreover, when CO changes, the sympathetic tone adapts to keep the mean arterial pressure constant. Even arterial pulse pressure, which should be physiologically the closest CO correlate, is unhelpful. Studies have shown that during volume expansion changes in CO and in pulse pressure were weakly correlated [7] or not correlated at all [8]. This is particularly true when arterial resistance changes, for instance due to changing vasopressors dosage [7].
Finally, haemodynamic monitoring cannot be merely limited to tissue oxygenation and ScvO2. It is correct that CO cannot be interpreted without knowing it, but the opposite is also true. During sepsis, if oxygen extraction is impaired, ScvO2 is unhelpful because it often remains normal. Also, during shock, when oxygen delivery is below its critical level, any increase in it is mainly used for increasing the oxygen consumption, such that ScvO2 does not increase as much as would be expected from the increase in CO.
Conclusions
Along with recommendations [9], it is reasonable today to defend CO monitoring in patients with shock. Of course, it should be reserved for the most critical cases, when initial treatment is ineffective [9]. For sure, all techniques are not equally accurate or invasive and do not provide the same amount of information; the choice should depend on the context and clinicians’ experience. Beyond CO, monitoring devices provide information that helps for diagnosis and management. The invasiveness of transpulmonary or classic thermodilution is not acceptable during routine surgical interventions, but their complication rate is compatible with the severity of critically ill patients [10]. Moreover, clinicians should be taught on how to use these techniques and should be aware of their limitations. Such teaching might also help clinicians understand the complex physiology of CO and tissue oxygenation. In any case, keeping in mind the arguments in favour of and against CO monitoring might help them make an informed choice.
Acknowledgments
None.
Funding
Institutional.
Availability of data and materials
Not applicable.
Abbreviations
- CO
Cardiac output
- ScvO2
Oxygen saturation of the central venous blood
Authors’ contributions
XM and J-LT wrote the manuscript. Both authors read and approved the final version.
Authors’ information
None.
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
J-LT and XM are members of the Medical Advisory Board of Pulsion Medical Systems.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Xavier Monnet, Email: xavier.monnet@aphp.fr.
Jean-Louis Teboul, Email: jean-louis.teboul@aphp.fr.
References
- 1.Monnet X, Julien F, Ait-Hamou N, Lequoy M, Gosset C, Jozwiak M, Persichini R, Anguel N, Richard C, Teboul JL. Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders. Crit Care Med. 2013;41(6):1412–20. doi: 10.1097/CCM.0b013e318275cece. [DOI] [PubMed] [Google Scholar]
- 2.Ince C, Mik EG. Microcirculatory and mitochondrial hypoxia in sepsis, shock, and resuscitation. J Appl Physiol (1985) 2016;120(2):226–35. doi: 10.1152/japplphysiol.00298.2015. [DOI] [PubMed] [Google Scholar]
- 3.De Backer D, Creteur J, Preiser JC, Dubois MJ, Vincent JL. Microvascular blood flow is altered in patients with sepsis. Am J Respir Crit Care Med. 2002;166(1):98–104. doi: 10.1164/rccm.200109-016OC. [DOI] [PubMed] [Google Scholar]
- 4.Richard C, Warszawski J, Anguel N, Deye N, Combes A, Barnoud D, Boulain T, Lefort Y, Fartoukh M, Baud F, et al. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA. 2003;290(20):2713–20. doi: 10.1001/jama.290.20.2713. [DOI] [PubMed] [Google Scholar]
- 5.Aya HD, Rhodes A, Ster IC, Cecconi M. Haemodynamic effect of different doses of fluids for a fluid challenge: a quasi-randomised controlled study. Crit Care Med. 2017;45(2):e161–8. doi: 10.1097/CCM.0000000000002067. [DOI] [PubMed] [Google Scholar]
- 6.Grissom CK, Morris AH, Lanken PN, Ancukiewicz M, Orme JF, Jr, Schoenfeld DA, Thompson BT. Association of physical examination with pulmonary artery catheter parameters in acute lung injury. Crit Care Med. 2009;37(10):2720–6. doi: 10.1097/ccm.0b013e3181a59532. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Monnet X, Letierce A, Hamzaoui O, Chemla D, Anguel N, Osman D, Richard C, Teboul JL. Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine. Crit Care Med. 2011;39:1394–9. doi: 10.1097/CCM.0b013e31820edcf0. [DOI] [PubMed] [Google Scholar]
- 8.Pierrakos C, Velissaris D, Scolletta S, Heenen S, De Backer D, Vincent JL. Can changes in arterial pressure be used to detect changes in cardiac index during fluid challenge in patients with septic shock? Intensive Care Med. 2012;38(3):422–8. doi: 10.1007/s00134-011-2457-0. [DOI] [PubMed] [Google Scholar]
- 9.Cecconi M, De Backer D, Antonelli M, Beale R, Bakker J, Hofer C, Jaeschke R, Mebazaa A, Pinsky MR, Teboul JL, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40(12):1795–815. doi: 10.1007/s00134-014-3525-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Hadian M, Pinsky MR. Evidence-based review of the use of the pulmonary artery catheter: impact data and complications. Crit Care. 2006;10 Suppl 3:S8. doi: 10.1186/cc4834. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not applicable.