Comparison of rigid and deformable registration through the respiratory phases of four-dimensional computed tomography image data sets for radiotherapy after breast-conserving surgery

Aiping Zhang a,b,d, Jianbin Li b,, Heng Qiu a,c, Wei Wang b, Yanluan Guo b
Editor: Eric Bush
PMCID: PMC5815729  PMID: 29390317

Abstract

Background:

The aim of this study was to compare the geometric differences in gross tumor volume (GTV) and surgical clips propagated by rigid image registration (RIR) and deformable image registration (DIR) using a four-dimensional computed tomography (4DCT) image data set for patients treated with boost irradiation or accelerated partial breast irradiation after breast-conserving surgery (BCS).

Methods:

The 4DCT data sets of 44 patients who had undergone BCS were acquired. GTV and selected clips were manually delineated on end-inhalation phase (CT0) and end-exhalation phase (CT50) images of 4DCT data sets. Subsequently, the GTV and selected clips from CT0 images were transformed and propagated to CT50 images using RIR and DIR, respectively. The geometric differences in GTV and surgical clips from DIR were compared with those of RIR.

Results:

The mean Dice similarity coefficient (DSC) index was 0.860 ± 0.042 for RIR and 0.870 ± 0.040 for DIR for GTV (P = .000). The three-dimensional distance to the center of mass (COM) of the GTV from RIR was longer than that from DIR (1.22 mm and 1.10 mm, respectively, P = .000). Moreover, in the anterior–posterior direction, displacements from RIR were significantly greater than those from DIR for both GTV (0.70 mm and 0.50 mm, respectively) and selected clips (upper clip, 0.45 mm vs 0.20 mm; inner clip, 0.55 mm vs 0.30 mm; outer clip, 0.40 mm vs 0.20 mm; lower clip, 0.50 mm vs 0.25 mm) (P = .000). However, in the left–right and superior–inferior directions, there were no significant displacement differences between RIR and DIR for GTV and the selected clips (all P > .050).

Conclusion:

DIR can improve the overlap for GTV registration from CT0 to CT50 images from 4DCT scanning. Furthermore, DIR is superior to RIR in reflecting the displacement of GTV and selected clips in the anterior–posterior direction induced by respiratory movement.

Keywords: breast-conserving surgery, deformable image registration, four-dimensional computed tomography, respiratory movement, rigid image registration

1. Introduction

Breast-conserving therapy (BCT) is the standard of care for early stage breast cancer. Accurately defining the tumor bed (TB) volume for radiation treatment planning is crucial for BCT to ensure proper coverage of tumors and spare organs at risk.[13] The critical factors leading to uncertainties in TB position between treatment and planning computed tomography scans during BCT include setup errors, respiration-induced target movements, and breast deformation. During radiotherapy, treatment and planning computed tomography scans are performed while the patient breathes freely, an activity subject to inherent motion artifacts.[4] Therefore, target motion caused by respiration during free breathing has recently become a focus of radiotherapy research.[5] By synchronizing computed tomography image acquisition to respiratory curves, four-dimensional computed tomography (4DCT) is used to assess respiratory-induced target motion and to determine internal target volumes for BCT.[6,7]

Although 4DCT images provide details regarding how the delineation of gross tumor volume (GTV) is influenced by respiratory motion, manually delineating GTVs at each phase of 4DCT scans is time consuming and labor intensive. The development of image registration has enabled advances in image-guided radiotherapy. Rigid image registration (RIR), which is widely used in many cancer centers, offers increased efficiency by aligning one CT image with another to accurately define the GTV for treatment.[8,9] However, RIR is also subject to inaccuracies caused by rigidly registering a nonrigid tissue and may not account for changes in the weight of the patient between scans, changes in the positioning of the patient, and soft-tissue displacements due to breathing. By tracking voxel-to-voxel changes from one CT image to another, deformable image registration (DIR) can correct for these changes by mapping between volume elements in one image and the corresponding volume elements in a subsequent image.[10] Previous studies relying on qualitative evaluations have suggested that DIR is almost always more accurate than RIR for assessing lung cancer.[11,12]

Although many studies investigating the usefulness of DIR have been conducted, its clinical impact on defining target volumes in 4DCT scans for treating breast cancer has not been reported. Therefore, the objective of this study was to evaluate the efficacy of DIR in assessing respiratory movements during intrafraction irradiation compared with the efficacy of RIR in 4DCT image data sets of patients undergoing radiotherapy after breast-conserving surgery (BCS). The results provide reference data for the application of 4DCT scans and image registration techniques to improve the delineation of target volumes influenced by respiratory motion.

2. Materials and methods

2.1. Patients

The study included 44 female patients with early stage breast cancer who had undergone BCS in our department between November 2014 and August 2016. The patients’ characteristics are listed in Table 1. The average interval from surgery to radiotherapy was 12 weeks (range, 2–24). Of the 44 patients, 68% were diagnosed with hormone receptor-positive breast cancer; 91% of these patients were receiving concurrent hormone therapy plus radiotherapy after BCS, and the other 9% were receiving sequential radiotherapy and hormone therapy after BCS. To improve delineation accuracy and consistency, all enrolled patients had 5 or more surgical clips fixed to the central bottom and lateral edges of the excision cavity to mark the lumpectomy cavity (LC) boundaries. Patients with restricted arm movement after surgery and poor pulmonary function were excluded. This study was approved by the institutional research ethics board of Shandong Cancer Hospital. Written informed consent was obtained from all patients.

Table 1.

Patient and tumor characteristics.

2.1.

2.2. 4DCT scans and image acquisition

All 44 patients were immobilized in the supine position on a breast board with both upper limbs outreached and lifted on arm brackets. During free breathing, 4DCT images were acquired, with a thickness of 3 mm, at the conclusion of a standard CT simulation using a 16-slice Brilliance Big Bore CT scanner (Philips Medical Systems, Inc., Cleveland, OH). Respiratory signals were recorded with a Varian Real-time Positioning Management (RPM) gating system (Varian Medical Systems, Palo Alto, CA) by tracking the trajectory of infrared markers placed on the patient's abdomen. GE Advantage 4D software (GE Healthcare, Waukesha, WI) sorted the reconstructed the 4DCT images into 10 respiratory phases based on these tags, with 0% corresponding to the end-inhalation phase (CT0) and 50% corresponding to end-exhalation phase (CT50). Next, the constructed 4DCT images were transferred to MIMvista version 6.1.0 (MIM Software, Cleveland, OH) for structure delineation.

2.3. Manual contouring of GTVs and selected clips

GTVs were manually contoured by the same radiation oncologist based on the placement of the surgical clips as a guideline on the CT0 and CT50 images of the 4DCT data sets, using seroma as a reference. GTVs delineated on the CT0 and CT50 images were defined as GTV0 and GTV50, respectively. The surgical clips representing the superior, inferior, posterior, and lateral boundaries of the LC were selected and marked as the upper, lower, inner and outer clips, respectively.

2.4. Registration procedure

For RIR and DIR, both the manually contoured GTV and selected clips on the CT0 image were propagated to the CT50 image using the MIM Registration package. The registration methods were largely automated, with user interaction limited to defining the region of interest for registration. The DIR process starts with a rigid registration of the CT0 images to the CT50 images. The user performs an automatic rigid registration and then evaluates the rigid registration. GTV0 was named Inline graphic after RIR. Once the rigid registration was accepted, the deformable registration and adaptive contouring module in the MIM software deformed the CT0 images to match the CT50 images. Eventually, the software, based on the calculated deformation matrix, mapped the CT0 contours (GTV and the selected clips) onto the CT50 images. GTV0 was named Inline graphic after deformation via DIR.

2.5. Three-dimensional coordinate measurement

The MIM software automatically outputs the 3D coordinates of the 2 sets of registered images for both the geometric center of the GTV and the selected clips, and these coordinates were recorded. Next, the peak-to-peak displacement (the maximum value of the coordinate minus the minimum value of the coordinate) of the clips and the geometric center of the GTV were obtained and marked as Δx, Δy, and Δz. The 3D distance to the center of mass (COM) was calculated as follows: Inline graphic. The results for the GTV and selected clips from DIR were compared with those from RIR.

2.6. Statistical analysis

To determine the degree of overlap between GTVs obtained using RIR and DIR, we used the Dice similarity coefficient (DSC). The DSC is a commonly used metric in medical imaging and contouring studies[26,27] and is defined as follows: DSC (A, B) = 2|AB|/(|A| + |B|). This metric has values ranging from 0, for no overlap, to 1, for perfect agreement between volumes.

Statistical significance was measured using paired t-tests if the Shapiro–Wilk normality test was passed (P > .05); otherwise, Wilcoxon signed-rank tests were used. Analyses were performed in SPSS 17.0. Results were considered statistically significant at P < .05.

3. Results

3.1. Comparisons of GTV and DSC between RIR and DIR

The image registration results are shown in Figure 1. GTV0, GTV50, Inline graphic and Inline graphic are listed in Table 2. There were no significant differences between GTV0 and GTV50 or between GTV50 and Inline graphic (all P > .050). Similarly, no significant difference was observed between GTV50Inline graphic and GTV50Inline graphic (z = −1.64, P = .101). The average Dice similarity coefficient (DSC) was 0.86 (95% confidence interval: 0.85–0.87) for RIR and 0.87 (5% confidence interval: 0.86–0.88) for DIR (Fig. 2). The mean DSC for DIR was significantly higher than for RIR (P = .000).

Figure 1.

Figure 1

Original manual contour of the gross tumor volume at CT50 (blue) and the registered gross tumor volume at CT0 (red) using (A) rigid image registration and (B) deformable image registration. CT = computed tomography^^.

Table 2.

3.1.

Figure 2.

Figure 2

Dice similarity coefficient (DSC) index values for the rigid image registration (RIR) and deformable image registration (DIR) methods for individual patients. DIR = deformable image registration, DSC = Dice similarity coefficient,

3.2. Three-dimensional comparisons of displacement

The centroid displacement of both GTVs and selected clips in the left–right, anterior–posterior and superior–inferior directions and the three-dimensional (3D) distances from the center of mass (COM) are listed in Table 3. There were no significant displacement differences between RIR and DIR in the left–right and superior–inferior directions for GTVs and the four selected clips (P > .05). However, in the anterior–posterior direction, displacements from RIR were significantly greater than those from DIR (P = .000). 3D distances to the COM from RIR showed greater movement than those from DIR (P = .000).

Table 3.

Centroid displacement of GTVs and selected clips from RIR and DIR (mm).

3.2.

4. Discussion

Intra- and, in particular, interobserver variation is an important issue during the delineation of the TB on CT scans when performing BCT. A standard contouring protocol can be used to decrease intra- and interobserver variability when delineating the TB volume.[13,14] Therefore, in our study, all delineations were performed by the same radiation oncologist according to unified guidelines to decrease geometric uncertainties. GTVs differed by as much as 6.5% between Inline graphic and GTV50 and 5.8% between Inline graphic and GTV50. Moreover, there was no significant difference in volume variation between RIR and DIR. GTV variation was similar for both registrations, suggesting that no sizeable volume progression occurred during DIR. In addition to comparing variations in target volume, we also analyzed differences in DSC values to evaluate volume alignment. A significant improvement was observed in the DSC for registration between Inline graphic and GTV50 compared with that between Inline graphic and GTV50 (Fig. 2). This can be explained by the fact that RIR allows a linear or uniform transformation of all voxels in the image set within six degrees of freedom. This means it has its own associated inaccuracies in registering nonrigid tissues. In contrast, DIR is able to compute nonlinear and nonuniform relationships between volume elements across imaging datasets. For this reason, it is increasingly applied in radiation oncology to register image sets. Other authors have also reported that DIR is superior to RIR with respect to variations in target volume and shape. For example, Fortin et al[15] observed that GTVs differed by as much as 30% between RIR and DIR for ten head and neck cancer patients.

For the selected clips, as rigid structures, no significant differences between RIR and DIR were observed in displacements in the left–right and superior–inferior directions when registering from CT0 to CT50 (P > .05). However, significant differences in displacements in the anterior–posterior direction were observed in the similar comparison (P = .000). Clips implanted at the boundaries of the surgical cavity are commonly used to delineate the TB volume and measure displacement for accelerated partial breast irradiation (APBI).[16] Wang et al[17] measured clip displacement and the geometric center of all clips based on 4DCT during free breathing and observed similar trends for the clips and their geometric center. Analogous to results from previous studies, our comparison of GTV displacement from RIR and DIR in the left–right, anterior–posterior and superior–inferior directions showed results similar to those for the selected clips. This may be attributable to (1) the slice-by-slice approach use in DIR, which results in no significant deformation in the longitudinal location; (2) the fixed position of the patient, such as lifting and outreaching both hands and lying in a supine position on the breast brackets; (3) breast size and shape; and (4) the location of the surgical cavity.

For both TB boost and partial breast irradiation, it is important to consider 3D displacement difference in determining the internal target volume (ITV).[18] We previously investigated respiratory-induced displacements in GTV.[17,19] Wang et al[17] measured geometric center displacement based on the 10 phases of 4DCT data sets during free breathing and determined that geometric center displacements in the left–right, anterior–posterior, and superior–inferior directions averaged 1.3 ± 0.4 mm, 2.0 ± 1.0 mm, and 1.9 ± 1.0 mm, respectively. Similarly, in our study, we concluded that centroid displacements between GTV0 and GTV50 in the left–right, anterior–posterior, and superior–inferior directions were 0.55 (0.00–2.90) mm 0.70 (0.00–2.60) mm, and 0.60 (0.10–3.20) mm, respectively. Despite these reports, it is unclear if the different image registration techniques provide similar information about spatial motion. Table 3 shows that DIR is superior to RIR in calculating 3D distances to the COM (P = .000). The superiority of DIR is attributable to the deformation of the breast, as well as the lumpectomy cavity caused by respiration and the effects of gravity during intrafraction irradiation; RIR has limitations in registering nonrigid tissue. Consequently, 3D distances to the COM based on DIR include centroid movements induced by respiration and the deformation of the breast. However, distances to the COM based on RIR only represent respiration-induced displacement. Therefore, DIR reflects intrafraction motion more accurately than RIR.

Many clinical studies have been performed to investigate the accuracy of DIR. Guckenberger et al[20] performed DIR in adaptive radiotherapy of lung cancer to assess the dosimetric impact of anatomic changes during treatment. To evaluate dose registration accuracy, Senthi et al[12] compared the spatial differences between RIR and DIR for 10 nonsmall cell lung cancer patients. They demonstrated that DIR was almost always more accurate than RIR and enabled improved the sparing of organs at risk. Our study indicates that the magnitude of the advantage of DIR is small when compared with RIR. For patients with a low local recurrence risk, APBI can achieve an adequate local control rate by targeting the location of the primary tumor and results in a shorter overall treatment time.[21,22] However, multicenter randomized trials reported that APBI increased rates of adverse cosmesis and late-radiation toxicity compared with standard whole-breast irradiation.[23,24] The significantly higher volume of tissue irradiated in patients with poor cosmesis is one of the potential factors explaining the increase in toxicity observed in the APBI arm of this trials. Therefore, an essential prerequisite for APBI is accurate delineation of the TB. Wang et al[25] reported that although the target movement was small during free breathing, the dose variation for the ipsilateral lung was significant. The results of our study can help guide patient-specific planning target volume (PTV) construction and reduce damage to normal tissues, resulting in fewer local recurrences, minimal toxicity, and excellent cosmetic outcomes.

5. Conclusion

DIR can improve the overlap for GTV registration from CT0 to CT50 images from 4DCT scans. Furthermore, DIR is superior to RIR in reflecting the displacement of GTV and selected clips in the anterior–posterior direction induced by respiratory movements.

Acknowledgments

This manuscript was edited for English language by American Journal Experts (AJE).

Footnotes

Abbreviations: 4DCT = four-dimensional computed tomography, BCS = breast-conserving surgery, DIR = deformable image registration, DSC = Dice similarity coefficient, GTV = gross tumor volume, RIR = rigid image registration, TB = tumor bed.

AZ and HQ equally contributed to this study.

This study was funded by Medicine and Health Science Technology Development Program of Shandong Province (No. 2013WS0346), Science and Technology Program of Shandong Academy of Medical Sciences (No. 2015-62), The National Key Research Program of China (No. 2016YFC0904700), National Natural Science Foundation of China (81502314), and Medical and Health Science Technology Development Program in Shandong Province (2016WS0549).

Consent to participate: The patients enrolled are consent to participate in our study.

The authors have no conflicts of interest to disclose.

References

  • [1].Fisher B, Anderson S, Bryant J, et al. Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer. N Engl J Med 2002;347:1233–41. [DOI] [PubMed] [Google Scholar]
  • [2].Veronesi U, Marubini E, Mariani L, et al. Radiotherapy after breast-conserving surgery in small breast carcinoma: long-term results of a randomized trial. Ann Oncol 2001;12:997–1003. [DOI] [PubMed] [Google Scholar]
  • [3].Bartelink H, Maingon P, Poortmans P, et al. Whole-breast irradiation with or without a boost for patients treated with breast-conserving surgery for early breast cancer: 20-year follow-up of a randomised phase 3 trial. Lancet Oncol 2015;16:47–56. [DOI] [PubMed] [Google Scholar]
  • [4].Chen GT, Kung JH, Beaudette KP. Artifacts in computed tomography scanning of moving objects. Semin Radiat Oncol 2004;14:19–26. [DOI] [PubMed] [Google Scholar]
  • [5].Qi XS, White J, Rabinovitch R, et al. Respiratory organ motion and dosimetric impact on breast and nodal irradiation. Int J Radiat Oncol Biol Phys 2010;78:609–17. [DOI] [PubMed] [Google Scholar]
  • [6].Zhao KL, Liao Z, Bucci MK, et al. Evaluation of respiratory-induced target motion for esophageal tumors at the gastroesophageal junction. Radiother Oncol 2007;84:283–9. [DOI] [PubMed] [Google Scholar]
  • [7].Yamashita H, Okuma K, Tada K, et al. Four-dimensional measurement of the displacement of internal fiducial and skin markers during 320-multislice computed tomography scanning of breast cancer. Int J Radiat Oncol Biol Phys 2012;84:331–5. [DOI] [PubMed] [Google Scholar]
  • [8].Hwang AB, Bacharach SL, Yom SS, et al. Can positron emission tomography (PET) or PET/computed tomography (CT) acquired in a nontreatment position be accurately registered to a head-and-neck radiotherapy planning CT? Int J Radiat Oncol Biol Phys 2009;73:578–84. [DOI] [PubMed] [Google Scholar]
  • [9].Gaede S, Olsthoorn J, Louie AV, et al. An evaluation of an automated 4D-CT contour propagation tool to define an internal gross tumour volume for lung cancer radiotherapy. Radiother Oncol 2011;101:322–8. [DOI] [PubMed] [Google Scholar]
  • [10].Brock KK. Image registration in intensity-modulated, image-guided and stereotactic body radiation therapy. Front Radiat Ther Oncol 2007;40:94–115. [DOI] [PubMed] [Google Scholar]
  • [11].Balik S, Weiss E, Jan N, et al. Evaluation of 4-dimensional computed tomography to 4-dimensional cone-beam computed tomography deformable image registration for lung cancer adaptive radiation therapy. Int J Radiat Oncol Biol Phys 2013;86:372–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [12].Senthi S, Griffioen GH, van Sörnsen de Koste JR, et al. Comparing rigid and deformable dose registration for high dose thoracic re-irradiation. Radiother Oncol 2013;106:323–6. [DOI] [PubMed] [Google Scholar]
  • [13].Guo B, Li J, Wang W, et al. Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation. Radiat Oncol 2015;10:66. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [14].Hurkmans CW, Borger JH, Pieters BR, et al. Variability in target volume delineation on CT scans of the breast. Int J Radiat Oncol Biol Phys 2001;50:1366–72. [DOI] [PubMed] [Google Scholar]
  • [15].Fortin D, Basran PS, Berrang T, et al. Deformable versus rigid registration of PET/CT images for radiation treatment planning of head and neck and lung cancer patients: a retrospective dosimetric comparison. Radiat Oncol 2014;9:50. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [16].Kirby AM, Coles CE, Yarnold JR. Target volume definition for external beam partial breast radiotherapy: clinical, pathological and technical studies informing current approaches. Radiother Oncol 2010;94:255–63. [DOI] [PubMed] [Google Scholar]
  • [17].Wang S, Li J, Wang W, et al. A study on the displacements of the clips in surgical cavity for external-beam partial breast irradiation after breast-conserving surgery based on 4DCT. J Radiat Res 2012;53:433–8. [DOI] [PubMed] [Google Scholar]
  • [18].Bartelink H, Horiot JC, Poortmans PM, et al. Impact of a higher radiation dose on local control and survival in breast-conserving therapy of early breast cancer: 10-year results of the randomized boost versus no boost EORTC 22881-10882 trial. J Clin Oncol 2007;25:3259–65. [DOI] [PubMed] [Google Scholar]
  • [19].Ding Y, Li J, Wang W, et al. A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery. Radiat Oncol 2014;9:76–176. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [20].Guckenberger M, Richter A, Wilbert J, et al. Adaptive radiotherapy for locally advanced non-small-cell lung cancer does not underdose the microscopic disease and has the potential to increase tumor control. Int J Radiat Oncol Biol Phys 2011;81:e275–82. [DOI] [PubMed] [Google Scholar]
  • [21].Wolmark N, Curran WJ. On behalf of NSABP protocol B-39/RTOG protocol 0413: a randomized phase III study of conventional whole breast irradiation versus partial breast irradiation for women with stage 0, I, or II breast cancer. National Surgical Adjuvant Breast and Bowel Project 2007;1–132. [Google Scholar]
  • [22].Polgár C, van Limbergen E, Pötter R, et al. Patient selection for accelerated partial-breast irradiation (APBI) after breast-conserving surgery: recommendations of the Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) breast cancer working group based on clinical evidence. Radiother Oncol 2010;94:264–73. [DOI] [PubMed] [Google Scholar]
  • [23].Liss AL, Ben-David MA, Jagsi R, et al. Decline of cosmetic outcomes following accelerated partial breast irradiation using intensity modulated radiation therapy: results of a single-institution prospective clinical trial. Int J Radiat Oncol Biol Phys 2014;89:96–102. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [24].Olivotto IA, Whelan TJ, Parpia S, et al. Interim cosmetic and toxicity results from RAPID: a randomized trial of accelerated partial breast irradiation using three-dimensional conformal external beam radiation therapy. J Clin Oncol 2013;31:4038–45. [DOI] [PubMed] [Google Scholar]
  • [25].Wang W, Bin Li J, Hu HG, et al. Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT. J Radiat Res 2013;54:755–61. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [26].Castillo R, Castillo E, Martinez J, et al. Ventilation from four-dimensional computed tomography: density versus Jacobian methods. Phys Med Biol 2010;55:4661–85. [DOI] [PubMed] [Google Scholar]
  • [27].Zhang T, Chi Y, Meldolesi E, et al. Automatic delineation of on-line head-and-neck computed tomography images: toward on-line adaptive radiotherapy. Int J Radiat Oncol Biol Phys 2007;68:522–30. [DOI] [PubMed] [Google Scholar]