Skip to main content
Sage Choice logoLink to Sage Choice
. 2017 Dec 15;60(2):160–171. doi: 10.1177/0018720817744661

Assessing Infant Carriage Systems: Ground Reaction Force Implications for Gait of the Caregiver

Mathew B Brown 1,, Caroline J Digby-Bowl 1, Samuel D Todd 1
PMCID: PMC5818031  PMID: 29244534

Abstract

Objective

To assess the acute alterations of anterior infant carriage systems on the ground reaction force experienced during over-ground walking.

Background

Previous research has identified the alterations in posture and gait associated with an increased anterior load (external or internal); however, the forces applied to the system due to the altered posture during over-ground walking have not been established.

Method

Thirteen mixed gender participants completed 45 over-ground walking trials at a self-selected pace under three loaded conditions (unloaded, semi-structured carrier 9.9 kg, and structured carrier 9.9 kg). Each trial consisted of a 15-m walkway, centered around a piezoelectric force platform sampling at 1,200 Hz. Differences were assessed between loaded and unloaded conditions and across carriers using paired samples t tests and repeated measures ANOVA.

Results

Additional load increased all ground reaction force parameters; however, the magnitude of force changes was influenced by carrier structure. The structured carrier displayed increased force magnitudes, a reduction in the time to vertical maximum heel contact, and an increased duration of the flat foot phase in walking gait.

Conclusion

Evidence suggests that the acute application of anterior infant carriers alters both kinetic and temporal measures of walking gait. Importantly, these changes appear to be governed not solely by the additional mass but also by the structure of the carrier.

Application

These findings indicate carrier structure should be considered by the wearer and may be used to inform policy in the recommendation of anterior infant carriage systems use by caregivers.

Keywords: biomechanics, gait, posture, kinetics, loading, product design

Introduction

The use of ergonomic aids, in the form of woven wraps, to assist in the transportation of infants has been and continues to be commonplace in developing countries throughout the world (Glover, 2012; Wu, Huang, & Wang, 2017). This approach has seen significant increase in developed countries over the past two decades (Frisbee & Hennes, 2000; Glover, 2012), resulting in the increased availability of commercial infant carriage devices. This trend can be in part attributed to its promotion by parenting organizations such as the National Childbirth Trust (2016), Babywearing International (2015), and the Centre for Babywearing Studies (2016). Proposed benefits include convenience, the promotion of physical development, child mental and physical health, safety, and improved health for the wearer (Natural Life Mom, 2012; Sling Babies, 2011). While some of these claims have been supported in the literature, including convenience (Wu et al., 2017), reduction in crying (Hunziker & Barr, 1986), and an increase in infant-mother attachment (Gathwala, Singh, & Balhara, 2008; Tessier et al., 1998), little attention has been directed toward the physical health of the caregiver, specifically, the short- and long-term implications of carrying an infant on the caregiver’s posture, gait, and structural health.

The task of infant carriage is ostensibly one of load carriage, either anteriorly or posteriorly; however, the majority of load carriage work examine the effects of posterior load on posture (Atwells, Birrell, Hooper, & Mansfield, 2006; Schiffman, Bensel, Hasselquist, Gregorczyk, & Piscitelle, 2006), gait (Birrell & Halsam, 2008, 2010; Birrell, Hooper, & Haslam, 2007), ground reaction force (Birrell et al., 2007; Cavanagh & LaFortune, 1980; Ciacci, Di Michelea, & Mern, 2010; Hsiang, Jiang, & McGorry, 1998; Lloyd & Cooke, 2000), fatigue (Qu & Yeo, 2011), and cardiovascular response (Fallowfield, Blacker, Willems, Davey, & Layden, 2012). Application of many of these findings are limited in reference to anterior load carriage given the significant differences reported by Fiolkowski, Horodyski, Bishop, Williams, and Stylianou (2006) in gait kinematics between anterior and posterior loads. However, findings associated with cardiovascular response, namely, the increased energy cost associated with an additional load, as measured by oxygen consumption and heart rate (Fallowfield et al., 2012), and increase in forces experienced proportionate to the load applied (Birrell et al., 2007) are more readily transferable. Consequently, the use of an anterior infant carriage system could have cardiorespiratory adaptations resulting in enhanced health and reduced disease risk, supporting the claims of parenting groups associated with the wearer’s health (Natural Life Mom, 2012; Sling Babies, 2011). However, focus on anterior load carriage has been sparse in the academic literature with reference to posture and gait parameters (Birrell & Haslam, 2008; Fiolkowski et al., 2006; Graham, Smallman, Miller, & Stevenson, 2014; Hsiang et al., 1998; Junqueira, Amaral, Lutaka, & Duarte, 2015; Perry et al., 2010). Findings indicate that anterior load carriage, using a front pack equivalent to 10% and 15% of participant mass, caused a reduced hip flexion and extension compared to unloaded walking (Fiolkowski et al., 2006). While application of a fixed 4.4 kg load (divers belt) identified a significant decrease in vertical ground reaction force at maximum vertical thrust at push off (Birrell & Haslam, 2008), no other vertical force measures were significantly altered by the fixed anterior load. This may have been a result of the alteration in the center of gravity caused by the anterior mass, reducing the impulse needed to accommodate the load at push off (Hsiang et al., 1998). Furthermore, Junqueira et al. (2015) identified significant alterations in trunk orientation when participants carried live infants and infant mannequins in their arms. These were characterized by increased trunk inclination, lumbar lordosis, and thoracic kyphosis during standing posture and walking (Junqueira et al., 2015).

Associated literature addressing impact of increased anterior load can be found in analysis of gait during pregnancy; Junqueira et al. (2015) highlighted commonalities in qualitative movement patterns of pregnant gait and postpartum infant carriage gait. Furthermore, significant reduction in walking velocity during pregnancy (McCrory, Chambers, Daftary, & Redfern, 2011) and postpartum infant carriage (Junqueira et al., 2015) has been established. These alterations are suggested to be compensatory to mitigate the increased instability of the caregiver/child system caused by changes in the position of the center of gravity (Branco, Santos-Rocha, & Vieira, 2014). Consequently, these similarities may indicate that mothers are well positioned to transfer from in vivo carriage to postpartum carriage; however, nonmaternal caregivers will have had no such adaptations. Furthermore, the TICKS guidelines developed by the Consortium of UK Sling Manufacturers (National Childbirth Trust, 2016) state that the child should be positioned high on the chest, close enough for the carer to kiss the child on the forehead. In comparison to previous research, where loads were carried in a much lower position, the center of gravity will be raised, and therefore the alterations in gait characteristics further exaggerate.

Considering the alterations in walking posture and kinematics (Fiolkowski et al., 2006; Junqueira et al., 2015), understanding the loading of the body is important as joints and muscles will be loaded outside of the general motor pattern, exposing the wearer to increased prospects of injury (Bonci, 1999). This could be magnified by a lack of pregnancy adaptations in nonmaternal caregivers; therefore, the use of anterior infant carriage systems could have health implications for caregivers. In light of the limited work toward understanding the impact of anterior load, and specifically, that no research has yet established the impact of anterior infant carriage on the caregiver, the aim of the current research was to ascertain the changes in ground reaction forces experienced when carrying an anterior load on the chest using an infant carrier. Moreover, it aims to determine acute alterations in temporal and kinetic parameters of the foot ground interaction experienced by the caregiver during walking and if this is affected by specific carrier structure.

Method

Participant Recruitment

Thirteen injury-free participants (female = 7; male = 6; mean age = 29.3 ± 8.65 years) volunteered to take part in this study. Participant demographics are presented in Table 1. This research complied with the tenets of the Declaration of Helsinki and was approved by the Institutional Review Board at Canterbury Christ Church University. Informed consent was obtained from each participant. Inclusion criteria required all participants to be free from injury at time of data collection and have had no back, lower limb, or shoulder injuries in the previous 12 months. No participants had given birth in the previous 12 months.

Table 1:

Participant Demographics

Gender N of Participants Descriptive Statistic Age (Years) Height (cm) Mass (kg) BMI (kg/m2)
Female 7 Minimum 23 162.30 57.60 19.80
Maximum 48 174.60 90.70 31.24
Mean 31.71 168.83 69.06 24.23
SD 10.84 5.20 11.74 3.94
Male 6 Minimum 23 179 65.30 19.67
Maximum 35 190.20 95 27.31
Mean 26.5 184.37 80 23.49
SD 4.59 4.29 11.67 2.90

No previous research was deemed acceptable for an a priori sample size estimation; therefore, post hoc power analyses were conducted for the repeated measures t test and repeated measures ANOVA. Using G*Power (v. 3.19.2) with an alpha of 0.05 and a large effect size (0.8), demonstrated power was 0.75 and 0.9 for the t tests and ANOVA, respectively.

Experimental Conditions

Participants completed 15 barefoot trials at a self-selected walking pace over a 15-m distance in each condition (unloaded 1.54 ± 0.03 m·s–1; and 2 anteriorly loaded conditions, structured [SC] 1.54 ± 0.03 m·s–1; semi-structured [SSC] 1.52 ± 0.03 m·s–1), making contact with their right foot on a force platform. Barefoot conditions were used to ensure that differences between shoe construction and condition between participants did not affect force measures as these have been demonstrated to influence force attenuation and foot and ankle kinematics during gait (Novacheck, 1998).

The unloaded condition was completed barefoot, wearing minimal clothing, defined as tight fitting top and sports shorts, and no carrier. The loaded conditions consisted of the wearing of two different anteriorly loaded infant carriers, one semi-structured and one structured, specifications for which can be found in Table 2. Both carriers were loaded with a purpose-made mannequin with the equivalent mass of a 12-month-old on the 50th percentile on the NHS (2017) growth charts (9.9 kg). A mannequin was used as it has previously been reported (Junqueira et al., 2015) that the carriage of a mannequin results in similar alterations in walking kinematics to carrying one’s own infant when compared to unloaded walking. Participants were instructed to allow their arms to swing naturally during walking trials rather than holding on to the mannequin and carrier. The order in which the participants completed each condition was randomized using an online research randomizer (Urbaniak & Plous, 2013).

Table 2:

Specifications of Infant Carriage Systems

Infant Carrier Semi-Structured Structured
Picture graphic file with name 10.1177_0018720817744661-img1.jpg graphic file with name 10.1177_0018720817744661-img2.jpg
Weight (g) 576 997
Material 100% cotton Main material: 60% cotton, 40% polyester
Lining: 100% cotton
Waist belt: 100% polyester
Mesh: 100% polyester
Cover for leg position zip: 100% cotton
Product features A comfortable and supportive baby carrier that allows you to carry on your front, hip, or back
Allows the carrier to grow with your child to fit any size of baby or toddler from newborn up to 4 years old
Baby is securely supported in the best position for healthy hip development
Wide shoulder straps to evenly spread the weight around your body and provide a custom fit for each user
Padded waist for extra comfort
Ergonomic baby carrier with wide seat area
Extra-padded shoulder straps
Good stability in the waist belt
Perfect for a newborn—no infant insert needed.
Front-facing carrying option
From newborn to 3 years
Acknowledged as a hip-healthy baby carrier by International Hip Dysplasia Institute

Instrumentation

Ground reaction force (GRF) data were sampled at 1,200 Hz via a 900 × 600 mm Kistler force platform (Model 9287BA, Kistler Instruments Ltd) using Bioware software (v5.3.0.7, Kistler Instruments Ltd). Timing lights (in house, Canterbury Christ Church University) recorded the time taken to complete the central 5 m of the over-ground walking trials, centered over the force platform, to allow calculation of walking velocity.

Data Analysis

Data files containing GRF components for over-ground walking were filtered in Bioware (v5.3.0.7, Kistler Instruments Ltd) using a dual-pass Butterworth low-pass filter with a cutoff frequency of 50 Hz (McCrory, Chambers, Daftary, & Redfern, 2013; McCrory et al., 2011). A Fast Fourier Transformation of 13 randomly selected trials revealed data to be below 45 Hz. GRF data files were exported from Bioware to Excel, where a purpose-written analysis template extracted key kinetic and temporal components for further analysis. Peak vertical and anteroposterior force and impulse were calculated as key events in the loading of the gait cycle and have been demonstrated to be important responders to assess force during general load carriage (Birrell, Hooper, & Haslam, 2007). Rates of force loading and unloading were included to assess acceleration changes to the caregiver and carriage system, beyond that of maximal amplitudes, as indication of increased injury risk (Greenhalgh, Sinclair, Protheroe, & Chockalingham, 2012). The mediolateral assessment was included, as despite the small magnitude of these during walking gait, research suggests mediolateral stability is important in similar anterior load carriage tasks (Branco et al., 2013; Branco, Santos-Rocha, & Vieira, 2014; Lymbery & Gilleard, 2005) and therefore was deemed important for inclusion. Calculations for all variables are outlined in Tables 3 and 4, Figure 2, and with reference to Figure 1, except rate from peak medial force to max lateral force was calculated using maximums prior to midstance (MS). The fastest and the slowest walking trials were removed from analysis, leaving 13 trials per condition per participant, and GRF data were normalized to body weight (BW), and temporal measures were normalized to contact time.

Table 3:

Kinetic Analysis

Unloaded Loaded (Combined) Semi-Structured (SSC) Structured (SC)
Peak force (BW)
 P4 Fy – max posterior brakinga,b,c,d −0.250 ± 0.008 −0.272 ± 0.008 −0.269 ± 0.009 −0.275 ± 0.008
 P8 Fy – max anterior propulsivea,b,c,d 0.271 ± 0.007 0.307 ± 0.008 0.304 ± 0.008 0.309 ± 0.009
 P3 Fx – medial peak forcea,b,d 0.068 ± 0.007 0.075 ± 0.008 0.074 ± 0.008 0.076 ± 0.008
Impulses (BW·s)
 I1 Fx – medial impulse 0.0020 ± 0.0002 0.0022 ± 0.0002 0.0022 ± 0.0002 0.0022 ± 0.0002
 I2 Fy – braking impulsea,b,c,d −0.0371 ± 0.0011 −0.0420 ± 0.0013 −0.0418 ± 0.0015 −0.0422 ± 0.0011
 I3 Fy – propulsive impulsea,b,c,d 0.0358 ± 0.0013 0.0406 ± 0.0013 0.0404 ± 0.0013 0.0409 ± 0.0013
Loading rates (BW·s–1)
Inline graphic Fz – impact loading ratea,b,c,d 51.285 ± 3.430 56.256 ± 3.680 55.678 ± 3.687 56.841 ± 3.746
Fz – load off ratea,b,c,d −16.615 ± 0.588 −18.725 ± 0.718 −18.413 ± 0.706 −19.038 ± 0.763
Fx – medial impact loading ratea,b,d 3.184 ± 0.458 3.681 ± 0.577 3.632 ± 0.547 3.730 ± 0.611
Fx - max med. to max lat. rateb,c 1.257 ± 0.235 1.428 ± 0.216 1.450 ± 0.207 1.406 ± 0.232
Fz – MHC to MS load off rateb,d,e −3.436 ± 0.298 −3.654 ± 0.299 −3.525 ± 0.304 −3.784 ± 0.307
Fz – MS to MaxT load rate 2.658 ± 0.164 2.734 ± 0.145 2.716 ± 0.156 2.751 ± 0.141
Fy – braking force rate −3.681 ± 0.379 −4.064 ± 0.493 −3.950 ± 0.477 −4.178 ± 0.516
Delta changes (BW)
 P6 – P5 Fz – MHC – MS differencea,b,d 0.543 ± 0.050 0.603 ± 0.050 0.585 ± 0.051 0.622 ± 0.050
 P5 – P7 Fz – MHC – MaxT differencea,b,d 0.057 ± 0.034 0.100 ± 0.038 0.089 ± 0.037 0.112 ± 0.039
 P7 – P6 Fz – MS – MaxT difference 0.486 ± 0.025 0.503 ± 0.023 0.496 ± 0.025 0.510 ± 0.022

Note. BW = body weights; MHC = maximum heel contact; MS = midstance; MaxT = maximum thrust.

a

Denotes significant difference between loaded and unloaded condition.

b

Denotes a significant finding from repeated measures ANOVA.

c

Denotes significant pairwise comparison between unloaded and semi-structured.

d

Denotes significant pairwise comparison between unloaded and structured.

e

Denotes significant pairwise comparison between semi-structured and structured.

Table 4:

Temporal Analysis

Calculation Unloaded Loaded (Combined) Semi-Structured Structured
graphic file with name 10.1177_0018720817744661-img4.jpg Contact time (s) 0.604 ± 0.009 0.607 ± 0.008 0.608 ± 0.008 0.606 ± 0.009
Time to impact peak (% CT) 3.95 ± 0.55 4.26 ± 0.91 4.49 ± 1.08 4.02 ± 0.80
Time to max heel contact (% CT)a 21.29 ± 0.44 20.65 ± 0.46 20.87 ± 0.53 20.43 ± 0.42
Time to midstance (% CT) 47.34 ± 0.61 47.87 ± 0.71 48.11 ± 0.74 47.64 ± 0.71
Time to MS from MHC (% CT) 26.05 ± 0.63 27.22 ± 0.72 27.23 ± 0.72 27.21 ± 0.72
Time to MaxT (% CT) 78.20 ± 0.43 78.46 ± 0.45 78.38 ± 0.48 78.53 ± 0.43
Time to MT from MHC (% CT)a,b,c 56.91 ± 0.47 57.81 ± 0.57 57.51 ± 0.61 58.11 ± 0.56
Time to MaxT from MS (% CT) 30.62 ± 0.57 30.55 ± 0.55 30.25 ± 0.55 30.86 ± 0.61
Time from MaxT to toe off (% CT) 21.80 ± 0.43 21.54 ± 0.45 21.62 ± 0.48 21.47 ± 0.43
Time max medial force to max lateral force (%CT) 20.64 ± 1.92 19.45 ± 1.60 19.35 ± 1.77 19.56 ± 1.55
Velocity final (m·s–1) 1.538 ± 0.031 1.532 ± 0.031 1.519 ± 0.030 1.545 ± 0.032

Note. % CT = percentage of contact time; MS = midstance; MHC = maximum heel contact; MaxT = maximum thrust.

a

Denotes a significant finding from repeated measures ANOVA.

b

Denotes significant difference between loaded and unloaded condition.

c

Denotes significant pairwise comparison between unloaded and semi-structured.

Figure 2.

Figure 2.

Vertical force parameter changes due to load and carrier type.

aDenotes significant difference between loaded and unloaded condition.

bDenotes a significant finding from repeated measures ANOVA, indicating difference between the three conditions.

cDenotes significant pairwise comparison between unloaded and semi-structured.

dDenotes significant pairwise comparison between unloaded and structured.

eDenotes significant pairwise comparison between semi-structured and structured.

Figure 1.

Figure 1.

Annotated typical ground reaction force trace. P1 – initial contact, P2 – impact force peak, P3 – medial peak force, P4 – max posterior braking, P5 – max heel contact, P6 – midstance, P7 – max vertical thrust, P8 – max anterior propulsive, P9 – toe off, I1 – medial impulse, I2 – braking impulse, I3 – propulsive impulse. Fx = mediolateral force; Fy = anterior posterior force; Fz = vertical force.

Statistical Analysis

Data were checked for normality using a Shapiro-Wilk test. Pairwise assessment of loaded (combination of the two loaded conditions) versus unloaded and between-carrier conditions were conducted to ascertain if carrier structure was associated with any significant differences in GRF. Pairwise comparison between loaded and unloaded were calculated using either a paired t test or a Wilcoxon matched pairs test, from which a Cohen’s d effect size was calculated and interpreted as small (0.2), medium (0.5), and large (0.8). Cross-carrier assessment employed either a repeated measures ANOVA across carrier condition, where significant differences were ascertained through pairwise comparison using a Bonferroni post hoc analysis or a Friedman test. Effect size for the repeated measures ANOVA was calculated using partial eta-square and interpreted as small (0.01), medium (0.09), and large (0.25). The alpha level for all tests was set to 0.05, and all tests were carried out using SPSS (version 22, IBM).

Results

Unloaded Versus Loaded

Kinetic analysis

Pairwise comparisons between unloaded (Un) and loaded conditions (Table 3) identified significant increases in impact force peak (IFP): t(10) = −3.243, p = .009, d = 0.98, Un: 0.745 ± 0.034, loaded: 0.869 ± 0.054; maximum heel contact (MHC): t(12) = −11.307, p = .000, d = 3.14, Un: 1.206 ± 0.032, loaded: 1.375 ± 0.034; midstance (MS): t(12) = –10.752, p = .000, d = 2.98, Un: 0.663 ± 0.019, loaded: 0.772 ± 0.019; and maximum vertical thrust (vertical force component propulsive peak; MaxT): t(12) = 14.714, p = .000, d = 4.08, Un: 1.149 ± 0.012, loaded: 1.275 ± 0.017, under loaded conditions. Rate of vertical force loading at heel contact (VLR) and rate of force unloading (VLOR) at end of stance also significantly increased when loaded, t(12) = −3.890, p = .002, d = 1.08; t(12) = 6.283, p = .000, d = 1.74, respectively.

Similarly, maximum posterior braking force (MPB), t(12) = 4.566, p = .001, d = 1.27, and maximum anterior propulsive force (MAP), t(12) = −6.734, p = .000, d = 1.87, significantly increased under loaded conditions. Loaded walking also resulted in significant increases in braking impulse (BI) and propulsive impulse (PI), t(12) = 8.921, p = .000, d = 2.47; t(12) = −7.852, p = .000, d = 2.18, respectively; however, rate of braking force (BLR) application was not significantly altered (z = −1.645, p = .101). Furthermore, load significantly increased the medial peak force (MPF), t(12) = −2.386, p = .034, d = .66, and medial loading rate (MLR), z = −2.481, p = .013, d = 0.69; however, medial impulse (MI) did not alter significantly.

In the transition from MHC to MaxT (the flat foot phase of stance), significant increases were evident in the magnitude of force changes between MHC and MS, t(12) = −2.812, p = .016, d = 0.78, and MHC and MaxT, t(12) = −3.156, p = .008, d = 0.88, under loaded conditions. However, these changes were not sufficient to significantly alter the load-off rate between MHC and MS and the rate of force application from MS to MaxT (p > .05) or the force magnitude change between MS and MaxT.

Temporal analysis

A significant, t(12) = −2.260, p = .043, d = −0.63, increase in time between the MHC and MaxT in the loaded condition (57.81 ± 0.57%) in comparison to unloaded (56.91 ± 0.47%) indicated that the load increased the time during which participant’s full foot was in contact with the force platform. No significant difference between loaded/unloaded conditions were observed for other temporal measures (Table 4).

Analysis by Carrier Type

Kinetic analysis

Significant findings in all vertical force measures from the paired samples t tests were duplicated in the overall effect of the repeated measures ANOVA when load was separated by carrier type. Post hoc pairwise comparisons identified the magnitude of the MHC, F(2, 24) = 96.589, p < .001, η2 = 0.89, was significantly higher under the SC condition (1.390 ± 0.034 BW), with MHC diminishing through the SSC condition (1.361 ± 0.035 BW) to the unloaded condition (1.206 ± 0.032 BW). All other vertical force measures exhibited no difference between SSC and SC, and this held true for the peak forces and impulses in anterior posterior forces. Medial impulse, F(1.359, 16.309) = 1.9, p = .171, η2 = 0.137, and MPF, F(1.399, 16.794) = 4.91, p = .031, η2 = 0.29, also echoed the paired samples analysis; however, Bonferroni post hoc pairwise analysis of the MPF was too conservative to identify the source of the significant difference. Further investigation using a lowest significant difference (equivalent to no adjustments) identified the source of the difference, with the SC condition (0.076 ± 0.008 BW) MFP magnitude being significantly higher than the unloaded condition (0.068 ± 0.007 BW). Resultantly, the same pattern of significance was identified in the MLR, χ2(2) = 6.615, p = .037, and the Wilcoxon post hoc identified significance between SC and unloaded (z = −2.481, p = .013, d = 0.69).

The transition from MHC to MaxT highlighted further impacts of the SC carrier condition. The magnitude change between MHC and MS, F(2, 24) =7.267, p = .003, η2 = 0.38, was significantly impacted by load condition, and post hoc testing highlighted a significantly greater drop from MHC to MS (SC: 0.622 ± 0.050, Un: 0.543 ± 0.050). This led to a significant increase in the load-off rate from MHC to MS, F(2, 24) =3.707, p = .040, η2 = 0.236. Interestingly, the SC condition (–3.784 ± 0.307 BW.s−1) was significantly faster than the unloaded (–3.436 ± 0.298 BW.s−1) but not the SSC (–3.525 ± 0.304 BW.s−1, p = .051) conditions, although this finding required the use of the least significant differences approach due to the conservative nature of the Bonferroni post hoc previously identified.

The magnitude of change between MHC and MaxT showed further significance alterations due to increased anterior load, F(2, 24) = 8.201, p = .002, η2 = 0.406; again, the SC condition (0.112 ± 0.039 BW) was significantly higher than unloaded (0.057 ± 0.034 BW).

Temporal analysis

A significant difference between conditions for the time between MHC and MaxT as a percentage of contact time, F(2, 24) = 5.152, p = .014, η2 = 0.30, was apparent. Post hoc pairwise comparisons identified a significant difference between unloaded (56.91 ± 0.47% CT) and the SC (58.11 ± 0.56% CT) condition; the SSC condition exhibited no significant difference (57.51 ± 0.61% CT). While the ANOVA for time from heel contact to MHC indicated significant differences, F(2, 24) = 3.475, p = .047, η2 = 0.23, Bonferroni post hoc tests were too conservative to identify the specific source of the difference reported. Further examination using a lowest significant difference (equivalent to no adjustments) post hoc assessment identified the significant difference between Un (21.29 ± 0.44% CT) and SC (20.43 ± 0.42% CT) conditions (p = .040). Examination of the data indicates that both the loaded conditions (SSC 20.87 ± 0.53% CT; SC 20.43 ± 0.42% CT) were characterized by a faster move to MHC than the Un condition (21.29 ± 0.44% CT), although not enough to significantly alter loading rate at impact.

Discussion

Previous studies have identified a decrease in walking velocity in response to the addition of an external anterior load (Junqueira et al., 2015) and internal anterior mass (McCrory et al., 2011). Our findings do not support this. While this contradiction was unexpected, previous work used mothers only and had the infant (or mannequin) supported in the arms; conversely, the focus of this work was to investigate the caregiver (non–gender specific) and investigated the effect of an ergonomic aid (carrier) to assist in the carriage task.

Statistically significant increases in peak vertical force parameters (IP, MHC, MS, MaxT) were demonstrated in both loaded conditions when compared with unloaded (Figure 2). These increases were in direct opposition to Birrell and Haslam (2008), who found a significant reduction in MaxT in response to the load, with all other measures demonstrating no change. This contradiction is likely due to the increased load used in the current study (9.9 kg vs. 4.4 kg, Birrell & Haslam, 2008) and could be influenced by the raised position of the anterior mass. Interestingly, the significant increase in MaxT combined with the significant increase in propulsive impulse, t(12) = 8.921, p = .000, d = 2.47, also contradicted the propositions of Hsiang et al. (1998), who suggested a decreased impulse was required at push off with an anterior load. These contradictions could have resulted from the nature of the task as previous research had addressed a load (Birrell & Haslam, 2008; Hsiang et al., 1998) and the current research was that of carrying an infant. While this proposition cannot be proved due to the psychological influences being outside of the scope of this paper, participants in the current study may have used an external focus of attention and as such altered the gait accordingly. It has been shown that this approach can affect motor patterns (Wulf, Weigelt, Poulter, & McNevin, 2003), and Junqueria et al. (2015) identified that mannequin carriage and infant carriage demonstrate similar variations from unloaded walking.

Increases early in foot contact, specifically the MHC, displayed variation beyond that of the load alone. The use of a structured carrier resulted in a significantly higher force (SC: 1.390 ± 0.034 BW) being experienced by the caregiver compared to the SSC and unloaded conditions (SSC: 1.361 ± 0.035 BW, Un: 1.206 ± 0.032 BW), which was deemed to have a large effect (η2 = 0.89). This may have been influenced by the significant reduction in time between heel contact and MHC, F(2, 24) = 3.475, p = .047, η2 = 0.225. Post hoc assessment identified significance values of 0.070 between SC and SSC and 0.040 between SC and unloaded, indicating that the use of the SC is characterized by a quicker transfer from heel contact to MHC through increased acceleration, therefore resulting in the increased force measured at MHC. When considered alongside the findings of Fiolkowski et al. (2006) and Junqueira et al. (2015), both of whom applied loads of similar magnitude to the current study (15% and 10 kg, respectively), and Bonci (1999), this indicates that the caregiver is being exposing to increased stresses and possibly enhanced risk of injury due to greater magnitude of all vertical forces, reduced time to maximum load (MHC), and the alterations in posture previously described.

The significantly higher MHC peak force resulted in further significant alterations in the loading patterns during walking. The magnitude of the reduction from MHC to MS was significantly larger under loaded conditions, t(12) = –2.812, p = .016, d = 0.78. Analysis by carrier identified statistical significance between SC and unloaded (p = .022). This linked to further significant differences between loaded and unloaded, F(2, 24) =3.707, p = .040, η2 = 0.24, with the rate of force unloading from MHC to MS being significantly faster under SC conditions when compared to the unloaded condition (SSC: p = .051), placing the caregiver under greater extremes of force. As a result, this may increase the likelihood of injury, if the carrier were employed for prolonged use, or could positively affect the caregiver through the overload principle attributed to resistance training (Winett & Carpinelli, 2001). Further research addressing prolonged use is needed to ascertain the veracity of these propositions.

The combination of the decrease in time from heel contact to MHC and maintenance of the contact time, t(12) = –0.558, p = .587, resulted in a significant increase in duration, as a percentage of contact time, between MHC to MaxT, with participants spending significantly longer in this transition when wearing the infant carriage systems. When carriage systems were separated, F(2, 24) = 5.152, p = .014, η2 = 0.30, the foundation of this increase was the SC, exhibiting an increase of 1.2%. This increase in time indicates a longer period of knee flexion during stance, requiring greater muscular effort, especially given the increased forces experienced under loaded conditions. Furthermore, increasing the time in the flat foot phase of stance may be indicative of participants attempting to stabilize the system. It has been reported through kinematic analysis that stability of the body is the primary focus of the pregnant woman during gait (Branco et al., 2013, 2014; Lymbery & Gilleard, 2005), and thus it could be expected that the same would be true of postpartum mothers and other caregivers when carrying an infant in a carrier system. While little previous research has identified kinetic changes (Lymbery & Gilleard, 2005), what has been identified supports the importance of stability. Although the temporal findings do not directly speak to previous research addressing stability, as emphasis has been placed on the importance of stability in the medio-lateral direction (Branco et al., 2013, 2014; Lymbery & Gilleard, 2005), they do indicate that an acute adaptation has been employed by participants resulting in a longer duration of flat foot contact and greater stability.

Analysis of the medio-lateral parameters from both the pairwise analyses and repeated measures ANOVA displayed mixed findings. Alterations in medio-lateral parameters were inconsistent; the medial impulse demonstrated no significant alteration due to load or carrier type, where rate of force transfer from medial to lateral peak, MPF, and MLR all displayed significant alterations in response to load. The rate of force transfer from medial to lateral during stance, although significant overall, χ2(2) = 6.000, p = .050, did not clearly demonstrate the specific source as post hoc analysis, using alpha level correction, and could not ascertain the specific source of the significance. The MPF and consequently MLR increases, t(12) = –2.386, p = .034, d = 0.66; Z = –2.481, p = .013, d = 0.69, respectively, were solely a function of the SC condition. These findings, combined with those from the temporal and vertical force analysis, indicate that carrier structure in addition to load has an influence on the magnitude of forces experienced by the wearer. Careful consideration is therefore required when selecting an anterior infant carrier.

Conclusion

Results indicate that the use of an infant carrier caused a significant increase in the magnitudes of the forces experienced during walking and altered the temporal characteristics of caregiver gait. The significant increases in the ground reaction forces are largely a result of the increased load applied to the system, with increases in both magnitude and rate of force application influenced. However, the localized changes due to carrier type in both kinetics and temporal measures indicate that carrier structure has an influence beyond the magnitude of the load. Resultantly, caregivers should be cautious when selecting and using such devices as these results are based on acute application only, without consideration of prolonged use. Further investigation would be merited in exploring the postural changes associated with the observed alterations in ground reaction force and the impact of prolonged use on the wearer.

Key Points

  • Carrying infants in ergonomic carriers has been said to improve the bond between caregiver and child, but the implications of wearer health have received limited attention.

  • Previous work has addressed maternal mothers only with no consideration for other caregivers in an infant’s life.

  • Results indicate that the load increases all aspects of ground reaction force; however, the magnitude and temporal alterations are dependent on carrier structure.

  • The structure of the carrier should be carefully considered when selecting ergonomic infant carriers as the acute alterations indicate that the structure impacts the magnitude of the forces experienced during over-ground walking.

Biography

Mathew B. Brown currently holds the position of senior lecturer in biomechanics at Canterbury Christ Church University, Canterbury, UK. He attained his PhD in sport biomechanics from the University of Southampton in 2009.

Caroline J. Digby-Bowl currently holds the position of senior lecturer in biomechanics at Canterbury Christ Church University, Canterbury, UK. She attained a first class degree in sport and exercise science from Brunel University in 2000.

Samuel D. Todd currently holds an intern position at Canterbury Christ Church University, Canterbury, UK. He attained a first class degree in sport and exercise science in 2015.

References

  1. Atwells R. L., Birrell S. A., Hooper R. H., Mansfield N. J. (2006). Influence of carrying heavy loads on soldiers’ posture, movements and gait. Ergonomics, 49(14), 1527–1537. [DOI] [PubMed] [Google Scholar]
  2. Babywearing International. (2015). Benefits of babywearing. Retrieved from http://babywearinginternational.org/what-is-babywearing/babywearing-resources/benefits-of-babywearing-2/
  3. Birrell S. A., Haslam R. A. (2008). The influence of rifle carriage on the kinetics of human gait. Ergonomics, 51, 816–826. doi: 10.1080/00140130701811859 [DOI] [PubMed] [Google Scholar]
  4. Birrell S. A., Haslam R. A. (2010). The effect of load distribution within military load carriage systems on the kinetics of human gait. Applied Ergonomics, 41, 585–590. doi: 10.1016/j.apergo.2009.12.004 [DOI] [PubMed] [Google Scholar]
  5. Birrell S. A., Hooper R. H., Haslam R. A. (2007). The effect of military load carriage on ground reaction forces. Gait & Posture, 26, 611–614. doi: 10.1016/j.gaitpost.2006.12.008 [DOI] [PubMed] [Google Scholar]
  6. Bonci C. M. (1999). Assessment and evaluation of predisposing factors to anterior cruciate ligament injury. Journal of Athletic Training, 34(2), 155–164. [PMC free article] [PubMed] [Google Scholar]
  7. Branco M., Santos-Rocha R., Aguiar L., Vieira F., Veloso A. (2013). Kinematic analysis of gait in the second and third trimesters of pregnancy. Journal of Pregnancy, 2013, 718095. doi: 10.1155/2013/718095 [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Branco M., Santos-Rocha R., Vieira F. (2014). Biomechanics of gait in pregnancy. The Scientific World Journal, 2014, 527940. doi: 10.1155/2014/527940 [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Cavanagh P., LaFortune M. A. (1980). Ground reaction forces in distance running. Journal of Biomechanics, 13, 397–406. [DOI] [PubMed] [Google Scholar]
  10. Centre for Babywearing Studies. (2016). Blog. Retrieved from http://www.centerforbabywearingstudies.com/new-layout-for-about/
  11. Ciacci S., Di Michelea R., Mern F. (2010). Kinematic analysis of the braking and propulsion phases during the support time in sprint running. Gait & Posture, 31(2), 209–212. doi: 10.1016/j.gaitpost.2009.10.007 [DOI] [PubMed] [Google Scholar]
  12. Fallowfield J. L., Blacker S. D., Willems M. E. T., Davey T., Layden J. (2012). Neuromuscular and cardiovascular response of Royal Marines recruits to load carriage in the field. Applied Ergonomics, 43, 1131–1137. doi: 10.1016/j.apergo.2012.04.003 [DOI] [PubMed] [Google Scholar]
  13. Fiolkowski P., Horodyski M., Bishop M., Williams M., Stylianou L. (2006). Changes in gait kinematics and posture with the use of a front pack. Ergonomics, 49(9), 885–894. doi: 10.1080/00140130600667444 [DOI] [PubMed] [Google Scholar]
  14. Frisbee S. J., Hennes H. (2000). Adult-worn child carriers: A potential risk for injury. Injury Prevention, 6, 56–58. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Gathwala G., Singh B., Balhara B. (2008). KMC facilitates mother baby attachment in low birth weight infants. The Indian Journal of Pediatrics, 75(1), 43–47. [DOI] [PubMed] [Google Scholar]
  16. Glover R. (2012). Research overview: Is there evidence to support the use of soft slings? Retrieved from https://www.nct.org.uk/sites/default/files/related_documents/Glover%20Research%20overview-%20Is%20there%20evidence%20to%20support%20the%20use%20of%20soft%20slings%20PerspSept12%20p18-20.pdf
  17. Graham R. B., Smallman C. L. W., Miller R. H., Stevenson J. M. (2014). A dynamical systems analysis of assisted and unassisted anterior and posterior hand-held load carriage. Ergonomics, 58(3), 480–491. doi: 10.1080/00140139.2014.978902 [DOI] [PubMed] [Google Scholar]
  18. Greenhalgh A., Sinclair J., Protheroe L., Chockalingam N. (2012). Predicting impact shock magnitude: Which ground reaction force variable should we use? International Journal of Sports Science and Engineering, 6(4), 225–231. [Google Scholar]
  19. Hsiang S. M., Jiang P., McGorry R. W. (1998). Load carrying, gait and stability. In Kumar S. (Ed.), Proceedings of the XIIIth Annual International Occupational Ergonomics and Safety Conference. Advances in Occupational Ergonomics and Safety (pp. 260–263). Amsterdam: IOS Press. [Google Scholar]
  20. Hunziker U. A., Barr R. G. (1986). Increased carrying reduces infant crying: A randomized controlled trial. Pediatrics, 77(5), 641–648. [PubMed] [Google Scholar]
  21. Junqueira L. D., Amaral L. Q., Lutaka A. S., Duarte M. (2015). Effects of transporting an infant on the posture of women during walking and standing still. Gait & Posture, 41(3), 841–846. doi: 10.1016/j.gaitpost.2015.02.014 [DOI] [PubMed] [Google Scholar]
  22. Lloyd R., Cooke C. B. (2000). Kinetic changes associated with load carriage using two rucksack designs. Ergonomics, 43(9), 1331–1341, doi: 10.1080/001401300421770 [DOI] [PubMed] [Google Scholar]
  23. Lymbery J. K., Gilleard W. (2005). The stance phase of walking during late pregnancy: Temporospatial and ground reaction force variables. Journal of the American Podiatric Medical Association, 95(3), 247–253. [DOI] [PubMed] [Google Scholar]
  24. McCrory J. L., Chambers A. J., Daftary A., Redfern M. S. (2011). Ground reaction forces during gait in pregnant fallers and non-fallers. Gait & Posture, 34(4), 524–528. doi: 10.1016/j.gaitpost.2011.07.007 [DOI] [PubMed] [Google Scholar]
  25. McCrory J. L., Chambers A. J., Daftary A., Redfern M. S. (2013). Ground reaction forces during stair locomotion in pregnancy. Gait & Posture, 38(4), 684–690. doi: 10.1016/j.gaitpost.2013.03.002 [DOI] [PubMed] [Google Scholar]
  26. National Childbirth Trust. (2016). Babywearing and how to choose a sling. Retrieved from https://www.nct.org.uk/parenting/babywearing-and-how-choose-sling
  27. Natural Life Mom. (2012). Babywearing benefits for baby and caregivers. Retrieved from http://naturallifemom.com/2012/09/babywearing-benefits-for-baby-and-caregivers/
  28. NHS. (2017). NHS growth charts. Retrieved from http://www.dchs.nhs.uk/assets/public/nhs_record_keeping/docs/Childrens%20red%20book.pdf
  29. Novacheck T. F. (1998). The biomechanics of running. Gait & Posture, 7(1), 77–95. doi: 10.1016/S0966-6362(97)00038-6 [DOI] [PubMed] [Google Scholar]
  30. Perry C. J., Kiriella J. B., Hawkins K. M., Shanahan C. J., Moore A. E., Gage W. H. (2010). The effects of anterior load carriage on lower limb gait parameters during obstacle clearance. Gait & Posture, 32(1), 57–61. doi:10.1016/j.gait post.2010.03.003 [DOI] [PubMed] [Google Scholar]
  31. Qu X., Yeo J. C. (2011). Effects of load carriage and fatigue on gait characteristics. Journal of Biomechanics, 44(7), 1259–1263. doi: 10.1016/j.jbiomech.2011.02.016 [DOI] [PubMed] [Google Scholar]
  32. Schiffman J. M., Bensel C. K., Hasselquist L., Gregorczyk K. N., Piscitelle L. (2006). Effects of carried weight on random motion and traditional measures of postural sway. Applied Ergonomics, 37(5), 607–614. doi: 10.1016/j.apergo.2005.10.002 [DOI] [PubMed] [Google Scholar]
  33. Sling Babies. (2011). The benefits of babywearing. Retrieved from http://www.slingbabies.co.nz/Site/Benefits.ashx
  34. Tessier R., Cristo M., Velez S., Giron M., de Calume Z. F., Ruiz-Palaez J. G., . . . Charpak N. (1998). Kangaroo mother care and the bonding hypothesis. Pediatrics, 102(2), e17. [DOI] [PubMed] [Google Scholar]
  35. Urbaniak G. C., Plous S. (2013). Research randomizer (Version 4.0) [Computer software]. Retrieved from http://www.randomizer.org/
  36. Winett R. A., Carpinelli R. N. (2001). Potential health-related benefits of resistance training. Preventive Medicine, 33(5), 503–513. doi: 10.1006/pmed.2001.0909 [DOI] [PubMed] [Google Scholar]
  37. Wu C-Y., Huang H-R., Wang M-J. (2017). Baby carriers: A comparison of traditional sling and front worn, rear-facing harness carriers. Ergonomics, 60(1), 111–117. doi: 10.1080/00140139.2016.1168871 [DOI] [PubMed] [Google Scholar]
  38. Wulf G., Weigelt M., Poulter D., McNevin N. (2003). Attentional focus on suprapostural tasks affects balance learning. The Quarterly Journal of Experimental Psychology Section A, 56, 1191–1211. doi: 10.1080/02724980343000062 [DOI] [PubMed] [Google Scholar]

Articles from Human Factors are provided here courtesy of SAGE Publications

RESOURCES