Critical care echocardiography (CCE) is performed and interpreted by the intensivist at the bedside to help in the diagnostic work-up and to guide therapy for patients with acute circulatory and respiratory failure. Due to the statement of educational standards, the validation of echocardiography against alternative hemodynamic monitoring tools, and continuous technological improvement, CCE is increasingly being considered as an unparalleled technique to hemodynamically assess critically ill patients. Extremely active research in the field of CCE has resulted in recent improvements which warrant comment (Table 1).
Table 1.
New developments in echocardiography in the critically ill |
1. CCE is currently recommended as the first-line modality to assess patients with shock |
2. CEE relies on basic and advanced levels of competence corresponding to distinct standardized educational requirements |
3. CCE guides the front-line intensivist in assessing fluid requirement |
4. CCE is currently recommended for the diagnosis of acute respiratory distress syndrome |
5. CCE uses a simple yet robust and sound diagnostic approach |
6. CCE becomes a monitoring rather than a diagnostic tool |
7. CCE benefits from continuous technological refinements (e.g., speckle tracking) |
8. CCE is ideally suited for guiding tailored management of unstable patients |
CCE critical care echocardiography
CCE provides unique morphological and functional information in real time to depict the hemodynamic profile of shock [1, 2]. The recent consensus on circulatory shock and hemodynamic monitoring of the European Society of Intensive Care Medicine suggests that CCE is the preferred modality to initially evaluate the type of shock as opposed to more invasive techniques. To provide adequate training of intensivists, international roundtables have recently detailed the theoretical knowledge and practical skills that should be mastered to achieve competence in both basic and advanced CCE. Basic CCE should be part of the initial training of all intensivists, whereas advanced CCE is an optional component of competency since it requires a more extensive and specific training [3]. Computerized simulation accelerates the learning curve of transesophageal echocardiography for the hemodynamic assessment of critically ill patients [4].
CCE helps to assess the fluid responsiveness and both the efficacy and tolerance of blood volume expansion in patients with shock, irrespective of their respiratory status [5]. A recent multicenter study prospectively assessed 540 ventilated patients with shock of any origin using transesophageal echocardiography and systematic passive leg raise to mimic a transient central blood volume expansion [6]. With the exception of the superior vena cava collapsibility index which was obtained in nearly all patients, dynamic indices proposed to predict fluid responsiveness were obtained in approximately 78% of patients. Respiratory variation of left ventricular outflow tract Doppler maximal velocity was the most sensitive index, whereas the superior vena cava collapsibility index was the most specific to predict fluid responsiveness. Due to a large range of uninformative values of dynamic indices, authors proposed using high yet specific threshold values to accurately predict fluid responsiveness in patients for whom inefficient fluid loading would be detrimental (e.g., acute respiratory distress syndrome), whereas a more liberal approach could be used in the remaining patients with repeated CCE assessment of both efficacy and tolerance of serial mini-fluid loadings [6]. Importantly, CCE solely can ascribe the respiratory variation of pulse pressure or stroke volume (pulse contour method) to a right ventricular failure (Fig. 1), and accordingly avoid a false-positive diagnosis of fluid responsiveness [7].
CCE plays a major role in the diagnostic work-up of patients presenting with acute respiratory failure [8]. In assessing left ventricular diastolic properties and filling pressure, CCE accurately identifies cardiogenic edema or weaning pulmonary edema, and potentially associated cardiopathy. According to the Berlin definition of the acute respiratory distress syndrome, echocardiography is recommended to exclude hydrostatic pulmonary edema. Since the prevalence of acute cor pulmonale in this clinical setting reaches 22%, a risk score has been proposed to select patients who should undergo CCE [9]. In addition, transesophageal echocardiography is the reference diagnostic modality to identify potentially associated patent foramen ovale [8].
Used as either a focused cardiac evaluation at the basic level or a comprehensive hemodynamic assessment modality at the advanced level, CCE yields valuable information which helps determine the mechanism of circulatory failure. Based on a pathophysiological approach integrated in the clinical context, CCE helps distinguish between persistent hypovolemia, left or right ventricular failure, tamponade, or any other source of central circulation impairment (Fig. 1). Its additional diagnostic capacity is particularly relevant in the setting of complicated open-heart surgery and for the management of patients supported with circulatory assistance where the therapeutic impact is high [10].
CCE provides accurate measurement of cardiac output [11]. Accordingly, CCE is used serially to assess the effects of passive leg raise or fluid challenge on left ventricular stroke volume [6], and its tolerance as reflected by induced changes in cardiac filling pressures [8]. When compared to other (“blind”) hemodynamic monitoring systems, CCE provides clinically relevant additional information. In 37 of 137 ventilated patients (27%) who were hemodynamically assessed for septic shock using both CCE and transpulmonary thermodilution, independent interpretation of hemodynamic profiles led to discrepant results and a source of discordance was identified by echocardiography in 43% of them [12]. Indeed, numerous hemodynamic burden or acute cardiac/great vessel conditions can only be accurately identified using CCE, including acute cor pulmonale [8, 9], dynamic left ventricular obstruction [13], massive valvular regurgitation or severe valvular stenosis, central anatomical shunts, proximal pulmonary embolism or aortic dissection [12].
Continuous improvements in electronics has enabled the emergence of miniaturized ultrasound systems and probes. Real-time three-dimensional echocardiography and new quantitative approaches for myocardial function based on speckle tracking promise to further improve the diagnostic capacity of CCE [14]. In patients with septic shock, global left ventricular longitudinal peak systolic strain measured using speckle tracking appears more sensitive than left ventricular ejection fraction to identify septic cardiomyopathy, since it is impaired in a large proportion of patients with preserved ejection fraction and it decreases before ejection fraction in the subset of patients who exhibit delayed left ventricular systolic dysfunction [15]. Whether this new index of left ventricular systolic function is prognostic remains to be established.
Overall, CCE offers a wide range of modalities and hemodynamic parameters to best help the front-line intensivist in adjusting acute therapy individually in patients with cardiopulmonary compromise, irrespective of their level of competence (basic, advanced, or expert). Recently proposed echocardiography-based management strategies and newly available technologies need further validation in large cohorts of critically ill patients. The best has yet to come.
Acknowledgements
Not applicable.
Funding
Not applicable.
Availability of data and materials
Not applicable.
Abbreviation
- CCE
critical care echocardiography
Authors’ contributions
PV wrote and approved the manuscript.
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
The author declares that he has no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.McLean AS. Echocardiography in shock management. Crit Care. 2016;20:275. doi: 10.1186/s13054-016-1401-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Orde S, Slama M, Hilton A, Yastrebov K, McLean AS. Pearls and pitfalls in comprehensive critical care echocardiography. Crit Care. 2017;21:279. doi: 10.1186/s13054-017-1866-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Yang Y, Royse C, Royse A, Williams K, Canty D. Survey of the training and use of echocardiography and lung ultrasound in Australasian intensive care units. Crit Care. 2016;20:339. doi: 10.1186/s13054-016-1444-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Prat G, Charron C, Repesse X, Coriat P, Bailly P, L'her E, Vieillard-Baron A. The use of computerized echocardiographic simulation improves the learning curve for transesophageal hemodynamic assessment in critically ill patients. Ann Intensive Care. 2016;6:27. doi: 10.1186/s13613-016-0132-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Boyd JH, Sirounis D, Maizel J, Slama M. Echocardiography as a guide for fluid management. Crit Care. 2016;20:274. doi: 10.1186/s13054-016-1407-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Vignon P, Repessé X, Bégot E, Léger J, Jacob C, Bouferrache K, Slama M, Prat G, Vieillard-Baron A. Comparison of echocardiographic indices used to predict fluid responsiveness in ventilated patients. Am J Respir Crit Care Med. 2017;195:1022–1032. doi: 10.1164/rccm.201604-0844OC. [DOI] [PubMed] [Google Scholar]
- 7.Vignon P, Merz TM, Vieillard-Baron A. Ten reasons for performing hemodynamic monitoring using transesophageal echocardiography. Intensive Care Med. 2017;43:1048–1051. doi: 10.1007/s00134-017-4716-1. [DOI] [PubMed] [Google Scholar]
- 8.Vignon P, Repessé X, Vieillard-Baron A, Maury E. Critical care ultrasonography in acute respiratory failure. Crit Care. 2016;20:228. doi: 10.1186/s13054-016-1400-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Mekontso-Dessap A, Boissier F, Charron C, Bégot E, Repessé X, Legras A, Brun-Buisson C, Vignon P, Vieillard-Baron A. Acute cor pulmonale during protective ventilation for acute respiratory distress syndrome: prevalence, predictors and clinical impact. Intensive Care Med. 2016;42:862–870. doi: 10.1007/s00134-015-4141-2. [DOI] [PubMed] [Google Scholar]
- 10.Douflé G, Roscoe A, Billia F, Fan E. Echocardiography for adult patients supported with extracorporeal membrane oxygenation. Crit Care. 2015;19:326. doi: 10.1186/s13054-015-1042-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Mercado P, Maizel J, Beyls C, Titeca-Beauport D, Joris M, Kontar L, Riviere A, Bonef O, Soupison T, Tribouilloy C, De Cagny B, Slama M. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient. Crit Care. 2017;21:136. doi: 10.1186/s13054-017-1737-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Vignon P, Bégot E, Mari A, Silva S, Chimot L, Delour P, Vargas F, Filloux B, Vandroux D, Jabot J, François B, Pichon N, Clavel M, Levy B, Slama M, Riu-Poulenc B. Hemodynamic assessment of patients with septic shock using transpulmonary thermodilution and critical care echocardiography. A comparative study. Chest. 2017. 10.1016/j.chest.2017.08.022. [DOI] [PubMed]
- 13.Paonessa JR, Brennan T, Pimentel M, Steinhaus D, Feng M, Celi LA. Hyperdynamic left ventricular ejection fraction in the intensive care unit. Crit Care. 2015;19:288. doi: 10.1186/s13054-015-1012-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.De Geer L, Engvall J, Oscarsson A. Strain echocardiography in septic shock. A comparison with systolic and diastolic function parameters, cardiac biomarkers and outcome. Crit Care. 2015;19:122. doi: 10.1186/s13054-015-0857-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Ng PY, Sin WC, Ng AKY, Chan WM. Speckle tracking echocardiography in patients with septic shock: a case control study (SPECKSS) Crit Care. 2016;20:145. doi: 10.1186/s13054-016-1327-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data