Abstract
Pumping of fluids with precise control is one of the key components in a microfluidic device. The electric field has been used as one of the most popular and efficient nonmechanical pumping mechanism to transport fluids in microchannels from the very early stage of microfluidic technology development. This review presents fundamental physics and theories of the different microscale phenomena that arise due to the application of an electric field in fluids, which can be applied for pumping of fluids in microdevices. Specific mechanisms considered in this report are electroosmosis, AC electroosmosis, AC electrothermal, induced charge electroosmosis, traveling wave dielectrophoresis, and liquid dielectrophoresis. Each phenomenon is discussed systematically with theoretical rigor and role of relevant key parameters are identified for pumping in microdevices. We specifically discussed the electric field driven body force term for each phenomenon using generalized Maxwell stress tensor as well as simplified effective dipole moment based method. Both experimental and theoretical works by several researchers are highlighted in this article for each electric field driven pumping mechanism. The detailed understanding of these phenomena and relevant key parameters are critical for better utilization, modulation, and selection of appropriate phenomenon for efficient pumping in a specific microfluidic application.
Keywords: micropump, electroosmosis, dielectrophoresis, electrothermal, lab-on-a-chip
1. Introduction
In last two decades, there are significant interests in the microfluidic-based separation platforms because these devices can provide rapid separation with higher resolution and whole channel detection, require smaller sample volume and consume much less reagent, are cheap to fabricate and disposable, need lower electric potential, etc. [1-6]. To perform the complete analysis in these lab-on-a-chip microfluidic devices, several functionalities have to be integrated. One of the key functionalities of these devices is pumping, which is needed for transporting the separated bands, moving reagents to the separation/mixing chamber, supplying the ligands/antibodies to the binding sites, etc. Since most microfluidic-based separations are performed applying an electric field, it is desirable to have an electric field driven nonmechanical pumping system. The key focus of this work is to highlight the recent progress made in the electric field driven pumping mechanisms of liquids in microfluidic chips.
When an electric field is applied to a liquid in a microfluidic device, a number of phenomena might occur depending on the type of liquids, liquid-surface interface, and nature of electric fields, which are generally known as electrokinetics. Although the first electrokinetic phenomenon is observed more than two-century back, many of them have only started getting attention in the late 1980s with the advent of the miniaturization techniques needed for this type of microdevice [7].
The major electrokinetic phenomena observed in microdevices are electroosmosis, electrophoresis, dielectrophoresis, Joule heating related electrothermal effect, induced charge electroosmosis, etc. Both electroosmosis and electrophoresis have century-long history and they are very widely explored in the context of separation. Electrophoresis is the motion of the charged particles or macromolecules in an electrolyte solution under the action of an applied electric field. The primary application of electrophoresis is to separate one analyte from others, or to concentrate a species from a dilute solution for detection or further processing. Depending on the type of electrolytes used, electrophoresis can be sub-divided into zone electrophoresis, moving boundary electrophoresis, isotachophoresis, isoelectric focusing, etc. [8]. These electrophoretic techniques are the workhorses of most analytical and bioanalytical works. To improve the separation resolution, two or more electrophoretic techniques can be hyphenated. In some instances, electrophoretic techniques are integrated with other types of separation methods, such as mass spectrometry to develop 2D or 3D separation platforms [1, 9, 10].
Electroosmosis is the motion of ionized liquid with respect to a stationary charged or polarized surfaces in presence of an applied electric field [11]. It is one of the very popular pumping technique used in the microfluidic device. Depending on the nature of the applied electric field and device configuration, electroosmosis can be classified as DC electroosmosis, time-periodic electroosmosis, AC electroosmosis and induced charge electroosmosis.
The history of DC electroosmosis goes back to 1809 when Reuss demonstrated the motion of fluid from the anode to cathode in a porous clay diaphragms [12]. In the mid 19th century, Wiedemann repeated the experiment and described the fundamentals of this phenomenon [13]. Until the early 1990s, most of the DC electroosmosis was restricted in capillary tubes, though the fundamental analysis for pure electroosmotic flow has been reported for both rectangular [14] and circular channels [15]. In 2002, a group of researchers has quantified the electroosmotic flow velocity distribution in a rectangular microchannel using microparticle image velocimetry, where they have demonstrated the plug like velocity distribution [16].
The time periodic electroosmosis concept was introduced by Dutta and Beskok in 2001 by applying an AC electric field along the channel [17]. In time periodic electroosmotic flow, the general structure of electric double layer remains the same, but the flow switches direction due to the change in the electric field direction. Later, these phenomena were extended to various microchannel geometries [18-20] and non-Newtonian fluids [21-23]. Although this technique has some merits for mixing of species in microchannels [24], it cannot be applied for pumping of fluids.
Unlike DC or time-periodic electroosmosis, in ACEO (AC electroosmosis), the surface charges are induced by externally applied voltages through the embedded electrode rather than from the naturally occurring charges on the channel surfaces [25]. Thus, the charge build-ups are hundreds of times stronger than DC electroosmosis. As a result, this technique can generate locally stronger forcing field for fluid flow. However, the ACEO technique is much more intricate as one must design and fabricate electrodes on the microchannel surface using expensive fabrication technique. Also, unlike DC electroosmosis, this method cannot be used for pressure build-ups, but an appropriately designed ACEO platform can provide local control in fluid flow which might be useful in many lab-on-a-chip devices.
Similar to ACEO, AC electrothermal (ACET) technique can be used for pumping of conductive fluids using an AC electric field through embedded electrodes on the channel surface [26]. Unlike ACEO, the ACET is operated at a higher frequency to avoid bubble formation due to the Faradic reaction. In ACET, the electric double layer cannot be formed next to the electrodes as the electrodes are energized at a frequency higher than the charge relaxation frequency.
The electric field can also be applied to transport micron and submicron sized particles immersed in a fluid. If these particles are charged, their motion is governed by the electrophoresis or combined electrophoresis and electroosmosis. On the other hand, if these particles are neutral (uncharged), it is still possible to manipulate them using a technique called dielectrophoresis [27]. Like ACEO and ACET, dielectrophoresis requires non-uniform electric field to move particles. In dielectrophoresis, an electric field is applied to the particles through a liquid or electrolyte. The applied electric field serves two purposes: it polarizes the particles and moves the particles towards the appropriate electric field zone. For instance, if the particle is more (less) polarizable than the media, it moves towards the higher (lower) electric field regions, which is known as positive (negative) dielectrophoresis. By introducing appropriate phase lags between consecutive electrodes [28, 29], it is possible to move particles in a preferred direction, which can introduce a fluid motion due to the viscous interaction between the particles and fluid. This phenomenon is popularly known as traveling wave dielectrophoresis (twDEP).
Another interesting electric field driven pumping mechanism is induced charge electroosmosis (ICEO) [30]. This technique shares some traits from both electroosmosis and dielectrophoresis. In induced charge electroosmosis, a stationary neutral post or charged surface can be polarized, one side has one type of net charge and the other side has the opposite net charge, using an electric field. The net surface charge (developed on the particle) from the polarization process can generate oppositely charged EDLs on the two sides of the particles, and the interaction of EDL and electric field can generate flow.
From aforementioned discussion, it is clear that not all electrokinetic phenomena are used for microfluidic pumping. In this review, we focus on a few major electrokinetic phenomena that have been reported as a potential pumping mechanism, either globally or locally, in the literature. The rest of the paper is organized as follows: First, we present the general governing equations for both linear and nonlinear electrokinetic phenomena. Next, we briefly introduce the working principles of various electric field driven pumping mechanisms. This is followed by the specific and simplified governing equations as well as auxiliary conditions for each pumping mechanisms. Then, we only review important works in this area. It is important to note that there are thousands of publications on electrokinetic pumping, and it is impossible to review all of them. In this review, our primary focus was to delineate the fundamental working principles of each electric field driven pumping technique along with similarities and dissimilarities among them. Readers are advised to consult the individual review papers on each topic for further information.
2. Background
Electrokinetics is a result of complex interaction among fluid species, electric field, induced thermal energy, dissolved ions, and object polarization. These interactions are governed by a number of equations which are discussed below. Depending on the types of electrokinetic phenomenon, one or more interactions play a dominant role, while other interactions can be safely ignored.
2.1 Formation of an Electric Double Layer
Electric double layer (EDL) forms when a charged surface comes in contact with an electrolyte, a liquid with free or mobile ions. Due to the presence of charges on the surface, the ions get redistributed close to the surface as shown in Figure 1(a). The formation of EDL next to a charged surface is the primary factor responsible for different types of electroosmosis.
In a dilute solution, the electric double layer consists of Stern and diffuse layers. The Stern layer is generally formed by an immobilized layer of counter ions (positive ions in this case) from the electrolyte, where the electrostatic interaction is very dominant. In the diffuse layer, both electrostatic and thermal energy play key roles. The concentration of the counter ions decreases from the charged surface, while the concentration of co-ions increases as shown in figure 1(b). At some distance from the charged surface, the electrostatic energy is balanced by the thermal energy, and that length scale is known as Debye length. For a symmetric binary electrolyte, the Debye length can be expressed as [31]
(1) |
where ε is the permittivity of the fluid medium, kB is the Boltzmann constant, T is the temperature in absolute form, e is the electron charge, z is the valence, and C0 is the concentration of ions in the bulk or electroneutral region. This relationship suggests that Debye length strongly depends on the electrolyte concentration, and it will be larger for a dilute solution compared to a concentrated one. Generally, the Debye length varies between 0.1 nm to 10 nm, which is much smaller than the typical microfluidic channel dimension (height or width), but for nanochannel, it is comparable to the channel dimension.
2.2 Electric Double Layer for Nonlinear Electrokinetics
In many microfluidic applications, such as AC electroosmosis, electrothermal, etc., a large electric field is applied to electrodes patterned on the channel surface. For the large charge density or large applied potential drop across the electric double layer, the inner diffuse layer is overcrowded [32], which is termed as condensed layer as shown in figure 2. Like the low surface potential case, both Stern layer and outer diffuse layers are present in this scenario.
When applied electric potential (ψ) is much larger than the thermal potential (ψt = kBT/ez), the dilute solution theory breaks down. This breakdown is not due to the exponential counter-ion distribution, but due to the Steric effects. The Steric limit is reached at the maximum concentration, and the corresponding critical potential [32]
(2) |
At steric limit, the maximum concentration of counter ions can be given as
(3) |
where a is the typical spacing between densely packed ions considering hydration effects and ion-ion interactions. In a series of papers [32, 33], Bazant and co-workers have presented the dynamics of electrolytes at large applied electric potential, and they have identified linear, weakly linear and highly nonlinear regimes as
(4) |
The steric effect will be dominant in many nonlinear electrokinetic phenomena, such ACEO and ACET. Thus, readers are advised to consult the earlier works of Bazant and co-workers [32, 33] on steric effects for AC electrokinetic processes where energizing electrodes are placed on the channel walls.
2.3 Polarization of an Object
Polarization is a process of accumulation of positive and negative charges at the two sides of the object or at the two sides of the interface between objects and fluid as shown in Fig 3. The accumulation of charges on the object also induces polarization within the fluid (Fig. 3b). The result of this is the formation of dipolar charge double layer, which facilitates different electrokinetic phenomena. For instance, if the applied electric field is spatially nonuniform, it creates a net force on the object and causes motion of the object in the fluid medium, which is known as dielectrophoresis (DEP). On the other hand, for a fixed post or an object, the dipolar charge double layer can facilitate fluid flow, and this phenomenon is termed as induced charge electroosmosis (ICEO)[34].
3. General Governing Equations for Electrokinetics
3.1 Ion Concentration and Electric Potential Distribution in an Electrolyte
In an electrolyte system, the distribution of ions depends on the applied or induced electric field. For a dilute solution, the mass concentration of species i can be obtained from the Nernst-Planck equation as [35]
(4) |
where C is the mass concentration and S is the reaction term. The mass flux of each species can be obtained by balancing the frictional term with the advection and electromigration as
(5) |
Here D, z, ω are the diffusion coefficient, valence and absolute mobility of species, and V⃑ and E⃗ are the velocity and electric field, respectively. The electric field is related to the electrostatic potential as
(6) |
The governing equations for the electric field can be obtained from Maxwell's equations by ignoring the magnetic effects. In a microfluidic channel with microelectrodes, the ratio of energy stored by the magnetic field to electric field can be given as [36]
(7) |
where χ is the magnetic permeability and ε is the permittivity of the medium. The magnetic field H⃗ can result from conduction and/or displacement current. If the conduction current dominates, the magnetic field can be approximated as σEL; while for dominant displacement current, the magnetic field can be estimated as εωEL [36]. Figure 4 shows that for typical microfluidic setting, the magnetic energy is much smaller than the electrical energy if the applied electric field frequency is less than 100 MHz, and Maxwell's electromagnetic equations can be simplified as [37].
(8) |
(9) |
(10) |
where D⃗ and J⃗ are the electric displacement vector and current density, and ρe is the total volumetric charge density. Equation (9) indicates that under the quasi-electrostatic condition, the electric field is irrotational. For a linear, isotropic and homogeneous medium, the material constitutive relation provides D⃗ = εE⃗. Thus, equation (8) can be rewritten as
(11) |
If ions are the major current carrier, the volumetric free charge density can be given as [38]
(12) |
where e is the electron charge.
One can obtain the charge conservation equation by performing divergence operation on equation (10) and by utilizing equation (8) as
(13) |
In an electrolyte system, the current density term consists of electromigration, diffusion, and advection (bulk flow) of charged species, which can be expressed as [39]
(14) |
where F is the Faraday constant. In an earlier work, Castellanos et al. [36] reported that, in most microfluidic system, the contribution of the diffusion and advection term is much smaller than the drift or electromigration term, and the charge conservation equation can be reduced to
(15) |
where the electrical conductivity is defined as
3.2 Fluid Flow and Temperature Distribution
The fluid flow in a channel is governed by the incompressible Navier-Stokes equations and continuity equation as [40]:
(16) |
(17) |
where ρf is the fluid mass density, V⃗ is the flow velocity, p is the pressure and F⃗ is the body force per unit volume. In Navier-Stokes equations, the first and second term of the left-hand account the transient and advective contribution in fluid flow, while the first and second terms on the right-hand side are related to pressure and viscous forces.
In most micro/nanofluidic system, the convective term is much smaller than the viscous term due to small length scale and ultra-low flow velocity. Thus, the advective term can be dropped from the Navier-Stokes equations, and it will not be discussed any further for the rest of the paper. However, the contribution of the remaining terms depends on the specific case. For instance, in time-periodic electrokinetic flow, the contribution of the transient term cannot be ignored. Similarly, in mixed pressure driven and electroosmotic flow [41], the contribution of the pressure term is very important. The body force might come from a number of sources, such as buoyancy force due to density difference [42], acoustic streaming [43-45], or electrokinetic force due to an electrical field [36]. In an electrical field driven flow, the electrokinetic body force term is primarily responsible for facilitating fluid pumping that arises due to the interaction between electric field and fluids.
The electrokinetic body force can be obtained from the Maxwell Stress Tensor (MST) which is regarded as the most reliable form to account for electric field driven forces [46]. The MST provides the comprehensive effect of electric field interactions among submerged particles and fluids. In most of the microfluidic electrokinetics, the frequency range for the applied electric field is low (less than 100 MHz) i.e. electric field wavelength is much higher than the typical electrode sizes. In such cases, the near field approximation holds and the effects of the magnetic field can be neglected, and the Maxwell's stress tensor based on energy principles can be given by [47]
(18) |
where is the unit tensor. The corresponding electrical field driven volumetric force density can be obtained by taking divergence as follows:
(19) |
The first term on the right-hand side represents force due to the free bulk charges, the second term represents force due to polarization i.e. dielectric force, and the last term provides the force due to electrostriction. Depending on fluid medium and the applied electric field, one or more terms of the equation (19) can be neglected. The specific term that is significant for specific electrokinetic phenomena is discussed in the respective sections.
Application of electric field also causes Joule heating in the electrolyte, which can change the fluid temperature either locally or globally. The amount of heat generation depends on the electrical conductivity of the electrolyte as well as the applied electric field. The electric field driven temperature distribution can be obtained from the following energy balance equation [48]
(20) |
where cp is the specific heat of the fluid, k is the thermal conductivity and Φ is the heat generation due to viscous dissipation. The viscous dissipation term is generally significant for highly viscous liquids. The last term on the right hand represents Joule heating [49] due to the applied electric field. Like the fluid flow equation, the advective term can be dropped from the energy equation for most micro/nanofluidic applications.
4. DC Electroosmosis
Electroosmosis or electroendosmosis is the motion of ionized liquid relative to the stationary charged surface under the action of an applied electric field. This is also known as fixed charge electroosmosis or conventional electroosmosis. Figure 5 shows the working principle of electroosmosis in a straight channel. In this particular example, it is assumed that the microchannel surface acquires negative charges and cation dominant electric double layers are formed adjacent to the channel surface. The application of an electrical field will result in the movement of cations and anions towards cathode and anode, respectively. As the ions move in an applied electric field, it drags the fluid along it. Since, in Figure 5, the EDL is rich in cations, there will be a net movement of fluid from the anode to the cathode.
Electroosmosis could be beneficial in some applications, such as in the transport of separated sample zone in isotachophoresis or it could be detrimental, as in the dispersion of protein bands in isoelectric focusing. In the separation process, the electroosmotic pumping can be controlled by modulating the surface charge characteristics.
Electric field induced electrokinetic body force is primarily responsible for electroosmosis. If we assume that the fluid medium is homogeneous throughout the channel, the electrokinetic body force can be approximated as ρeE⃗. This body force is only dominant in the EDL region since the region outside of the EDL is electrically neutral. For pure electroosmotic flow through a channel, it is possible to obtain an analytical solution for flow velocity by balancing the body force term with the viscous term as [41]
(21) |
where ψ is the electric potential in the fluid, Ex is the tangential electric field, y is the coordinate measuring from the channel centerline, and ζ is the zeta potential. At the channel surface, the electric potential approaches zeta potential, and the flow velocity approaches zero in order to satisfy the no-slip boundary condition at the channel surface. For a thin EDL case, the electric potential drops to zero for most of the channel, and the flow velocity can be approximated as uniform throughout the channel with the Helmholtz-Smoluchowski velocity
(22) |
For most microfluidic applications, the EDL region (0.1-10 nm) is much smaller than the channel height (10-100 microns). Thus, for those flows, electroosmotic flow can be modeled with the Helmholtz-Smoluchowski slip velocity at the channel wall. However, for the nanofluidic channel, where the channel size is comparable to the electric double layer, one should avoid the prescription of Helmholtz-Smoluchowski slip velocity at the channel wall. Rather, no slip and no penetration boundary conditions should be exercised in those cases.
The electroosmotic flow velocity equation indicates that the nature of flow will depend on the type of channel materials since zeta potential is an indicator of surface charge density. The effect of substrate types on the EOF velocity profile is shown in Figure 6 [50]. For PDMS and fused-silica capillary microchannel, the flow is plug like, while for hybrid acrylic/PDMS microchannel, there is higher velocity in the middle of the channel compared to the edge. Authors hypothesized that this flow pattern variation from plug-like velocity is due to different surface charge densities at the top and bottom layer as well as due to the temperature variation caused by different thermal conductivities of acrylic and PDMS materials. Sinton et al. [51] also reported that EOF velocity deviates from plug-like flow if there is a non-uniform temperature distribution in the channel.
In electroosmotic flow through a microfluidic channel, the non-uniform surface charge density can create an adverse or favorable pressure gradient. At steady state, this combined electroosmotic and pressure-driven flow can be estimated by adding a pressure driven flow component as [52]
(23) |
where H is the channel half height. For a favoarable (adverse) pressure gradient, the dP/dx is negative (positive).
4.1 DC electroosmosis as Pumping Mechanism
In last two decades, the electroosmotic flow has been studied extensively both experimentally and theoretically. Dutta et al. [52] have presented the pressure building ability of DC electroosmotic flow using a hybrid microchannel consisting of materials with different surface electrical properties (zeta potential). Similar conclusions were obtained from the experimental works of Herr et al. [53].
Electroosmosis in microfluidics is mainly used to transport species or generate fluid flow [54]. Table 1 shows a few selected electroosmotic pumping works carried out by various researchers in last two decades. The maximum pressure generated by an electroosmotic pump can be expressed as
Table 1. Comparisons of various electroosmotically driven micropumps.
Author and Year | Flow Rate | Max Pressure | Applied Voltage | Pore Size | Pump Type |
---|---|---|---|---|---|
Gan et al. 2000 [55] | 3.0 ml/min | 0.15 MPa | 500 V | 2–5 μm | porous-membrane |
Zeng et al. 2001 [56] | 3.6 μl/min | 20 atm | 2 kV | packed-column | |
Yao et al. 2001 [57] | 7 ml/min | 2 atm | 200 V | open-channel | |
Zeng et al. 2002 [58] | 0.8 ml/min | 2 atm | 1.0 kV | packed-column | |
Lazar et al. 2002 [59] | 10-400 nl/min | 80 psi | 2 kV | open-channel | |
Chen et al. 2002 [60] | 15 μl/min | 0.33 atm | 1 kV | open-channel | |
Laser et al. 2002 [61] | 13 μl/min | 6 kPa | 400 V | open-channel | |
Takamura et al. 2003 [62] | 415 nl/min | 800 Pa | 10 V | open-channel | |
Yao et al. 2003 [63] | 33 ml/min | 1.3 atm | 100 V | 1.2 and 0.55 μm | porous-membrane |
Laser et al. 2003 [64] | 170 μl/min | 10 kPa | 400 V | open-channel | |
Tripp et al. 2004 [65] | 0.41 ml/min | 0.38 MPa | 50 V | 1700 nm | porous monolith |
Razunguzwa et al. 2004 [66] | 2 μl/min | 3 kV | packed-column | ||
Chen et al. 2005 [67] | 4.2 μl/min | 26 MPa | 8 kV | packed-column | |
Brask et al. 2005 [68] | 6 μl/min | 450 KPa | 30 V | 200 nm | porous-membrane |
Chen et al. 2005 [69] | 0.4 μl/min | 0.4 MPa | 6 kV | micrometer | porous monolith |
Yao et al. 2006 [70] | 3.2 ml/min | 30 kPa | 25 V | 1 to 3 μm | porous-membrane |
Wang et al. 2006 [71] | 2.9 μl/min | 3 atm | 6 kV | 4 μm | porous monolith |
Nie et al. 2007 [72] | 0.1 μl/min | 2.4 bar | 2 kV | porous monolith | |
Nie et al. 2007 [73] | 400 nl/min | 2 kV | porous monolith | ||
Miao et al. 2007 [74] | 86 ml /cm2 min | 70 V | 50-200 nm | porous monolith | |
Vajandar et al. 2007 [75] | 0.125 ml/min-V/cm2 | 3 V | 30–100 nm | porous membrane | |
Seibel et al. 2007 [76] | 10 nl/min | 65 Pa | 40 V | microchannel | |
Joo et al. 2007 [77] | 262.4 nl/min | 1 kV/cm | open-channel | ||
Wallner et al. 2007 [78] | 11.9 μl/min/mm2 | 5.2 kPa | 60 V | >500 μm | porous membrane |
Edwards et al. 2007 [79] | 0.19–2.30 μl∕min | 40-400 V | open channel | ||
Chen et al. 2008 [80] | 0.09 ml/min V/cm2 | 25 kPa | 20 V | 20, 100 and 200 nm | porous membrane |
Borowsky et al. 2008 [81] | 20 to 70 nl/min | 800 psi | 1.5-4.5 kV | 50 μm | porous monolith |
Berrouche et al. 2008 [82] | 13.6 ml∕min | 2 kPa | 150 V | nanoporous | |
Chen et al. 2008 [83] | 2.125 μl/min | 42 MPa | 4 kV | packed-column | |
Ai et al. 2010 [84] | 275 μl/min | 5 V | 200 nm | porous membrane | |
Shin et al. 2011 [85] | 5-30 μl/min | 7 kPa | 0.2-0.8 V | 1 μm | porous membrane |
Nagarale et al. 2011 [86] | 26 ± 3 μl/min | 1 V | 0.7-1 μm | porous membrane | |
Gu et al. 2012 [87] | 287 nl/min | 1208 bar | 10 kV | 700 nm | porous monolith |
Cao et al. 2012 [88] | 5 ml/min | 900 Pa | 11 V | 5 micron | open-channel |
Luong et al. 2013 [89] | 0.7 ml/min | 9 × 104 Pa | 7.5 V | 3.2 μm | porous medium |
Parashchenko et al. 2014 [90] | 325 μl/min | 300 V | 8-9 μm Channel dia | porous membrane | |
Li et al. 2016 [91] | 122 pL/s | 50 V | 80 μm Channel dia | microchannel |
(24) |
where d and Δφ are the channel diameter and applied potential difference. Thus, the pumping power of an electroosmotic pump can be raised by increasing the zeta potential, the permittivity of the medium and the applied electric field, or by decreasing the tube diameter. Various researchers have tried to maximize the pressure building ability by modulating different parameters with various degrees of success. The use of nanofluidic channel is the most popular method since there has been enormous interest in the development of the nanostructured devices. However, the flow rate supplied by the nanofluidic channel is sometimes not adequate; 10∼1000 of nanofluidic channels are needed to maintain the desired flow rate. Based on the nanochannel design and fabrication processes, the electroosmotic pump can be classified as open channel, packed-column, porous membrane, porous monolith, etc. In the following section, we report different types of classical electroosmotic pump that have been used in microfluidic devices as a pumping mechanism.
4.1.1 Open-channel electroosmosis
This type of electroosmotic pump is generally composed of 10 to 1000 open parallel microchannels or capillaries to provide fluid flow in a large diameter channel. Figure 7 shows the basic structure of such a micropump as presented in the work of Lazar and Karger [59], where they microfabricated a pump with numerous microchannels. Authors claimed to obtain a flow rate ranging from 10 to 400 nL/min using 1-100 microchannels. They also provided an expression for pressure generated by open channel electroosmotic pump as [59]
(25) |
where L1 is the applied electric field in the narrow channels. The discharge of such a pump can be obtained as
(26) |
These model equations are in good agreement in predicting their experimental results. Adopting similar concept, Darabi et al. [92] developed an electroosmotic micropump using numerous open channels to cool down an electronic chip. Reichmuth et al. [93] presented an open channel EOF pump for HPLC separation by increasing the dielectric constant of the working fluid. Their new design improved the pressure generation and efficiency up to 85% and 140%, respectively. Similar high pressure, larger flow rate, higher efficiency open channel electroosmotic micropumps are reported by [57, 77, 79, 88, 94].
A cascade electroosmotic pump consisting of multiple narrower (5μm × 20 μm) and wider (50 μm × 20) channels was reported by Takamura et al. [62] as shown in figure 8. The main objective of their micropump is to operate at low voltage to avoid Joule heating as well as bubble formation by serially connecting a number of pumping blocks, where the total applied potential difference remains same as in one block. Each pumping block consists of narrow channels and a wide channel (Fig 8a), and the configuration for applied electric potential is shown in figure 8b. According to their unique design, a larger favorable pressure gradient can be developed in narrower channels, while much smaller adverse pressure gradient is formed in the wide channel. Thus, the total pressure difference in each module can be obtained by subtracting the pressure required in the wide channel from the pressure generated in narrower channels. Figure 8c shows the pressure developed by a cascade EOF pump for different applied electric potential. Their experimental results show that pressure is higher with increased number of stages, but the fluid velocity remains the same at both the 6 and 15 stages for a particular electric field.
4.1.2 Packed-Column electroosmosis
In packed-column EOF pump, a capillary is filled with micron-sized particles and the capillary ends are sealed by frits like electrochromatography column. Paul et al. 1998 [95] have demonstrated the feasibility of a packed column micropump, where they obtained pressure in excess of 8,000 psi using micron size particles. Later, Zeng et al. 2001 [56] developed a packed column micropump and presented the performance of the electrokinetic pump using a setup similar to regular pump testing station (Fig. 9a).
As shown in Fig 9b, in a packed column electroosmotic pump, the flow rate can be increased by increasing the applied voltage for a fixed back pressure. The small nonlinearity in experimental flow rate vs applied voltage was due to a slight variation of the back pressure in their experiments. Figure 9c shows pump curve for the packed column electroosmotic pump, where they observed bubbles when back pressure is below 7 atm. The pump discharge remains constant in this bubble formation region. Their pump was capable of producing a maximum flow rate of 17 μL/min and a maximum pressure of 20 atm. Later, a number of researchers integrated the packed-column electroosmotic pumps with HPLC, liquid chromatography, nanoflow gradient generator, and ion exchange beads for various operating pressure and flow rate [58, 66, 67, 83, 96, 97].
4.1.2 Porous-Membrane electroosmotic pump
In this type of pump, a porous membrane is utilized to construct the main functional unit of the pump. This porous membrane contains numerous tortuous channels that are connected from one side of the membrane to the other [98]. Unlike packed column electroosmotic pump, the length of the channels in a porous membrane is much shorter [63]. Thus, a much higher electric field can be achieved with low applied voltage.
Miao et al. [74] demonstrated a porous membrane electroosmotic micropump, where the membrane is fabricated by anodization of aluminum foils in acidic solution. Figure 10c illustrates a schematic of their micropump, while Figs 10(a) and 10(b) show the images of the highly arranged nanochannels. The core pumping (membrane) section is fixed with plates on both sides to withstand the pressure generated by the electroosmotic pump, and it is placed between the inlet and outlet reservoirs. An electric potential difference of 0.1 to 70 V is applied to gold or platinum electrodes on the two sides of the membrane. They reported almost linear flow rate increase with an electric field (Fig. 10d), and for a particular applied electric field, the largest diameter pore provided highest flow rate. By changing the anodization process, they were able to obtain nanochannels of different diameters ranging from 5 nm to 280 nm for their membranes. Moreover, they presented a way to improve the flow rate by treating the channel surface with different chemicals, which improves the surface electrical characteristics for electroosmotic pumping. For instance, they reported that silica coated nanochannels can produce 108 times larger flow rate than the untreated nanochannel.
Similar porous silicon membrane based electroosmotic pumps are reported in [55, 68, 78, 85, 86, 90, 99] for various flow rate, pressure and applied electric fields. The performance of the pump depends on porosity, zeta potential, and pore's sizes. Yao et al. [99] reported a maximum flow rate of 3.2 ml/min and a maximum pressure of 730 Pa for a 350 μm thick silicon membrane, with pore sizes of 3 μm and 1 μm, respectively. For a fixed applied voltage, Chen et al. [80] have shown that flow rate can be increased by increasing the pore size. However, if the membrane size is very thin, then droplets may generate at low voltages [100]. Soumitra et al. [101] modified the zeta potential of the pores' inner surface by depositing different coating materials to control flow.
4.1.4 Porous monolith electroosmosis
In this case, a monolith column is used as a pumping component. Unlike a packed column or a porous membrane electroosmotic micropump, frits are not required in a monolith electroosmotic pump [102]. Organic polymer or inorganic silica-monolith can be used for the development of porous monolith electroosmotic pump [71, 103]. Tripp et al. 2004 [65] fabricated electroosmotic pumps based on microporous polymer monoliths. They investigated the effect of pore sizes on the monoliths, crosslinking density, and applied voltage on flow rate and pressure. Their electroosmotic pump can generate a flow rate of 0.41 ml/min and the measured pressure was about 0.38 MPa. Similar porous monolith based electroosmotic pumps are also reported by other groups [104, 105]. Gu et al. 2012 [87] reported the assembly of multiple monolith electroosmotic pump in series, while Nie et al. 2007 [72] reported the assembly of nine parallel electroosmotic pumping systems for higher flow rate and pressure. Porous monolith electroosmotic pumps are used for various applications, such as flow injection system [69], liquid preconcentration and delivery process [73], and the separation of explosive molecules [81].
5. AC Electroosmosis (ACEO)
Similar to DC electroosmosis, discussed in the previous section, AC electroosmosis can drive the bulk fluid through the interaction of double layers and external electric fields. However, in AC electroosmosis, a time-periodic electric field is applied between a pair of neighboring electrodes as shown in Figure 11. The charging of these electrodes with an AC current not only provides the tangential component of electric field, but also the surface charges on the electrodes for the creation of EDL. During the first half of the AC electric signal (Fig. 11a), the polarities of left and right electrodes are positive and negative, respectively. Thus, the electric field (green line) is from the left electrode to the right one during the first half cycle. Moreover, the positively polarized left electrode creates an EDL parallel to the electrode which is dominant in anions, while the negatively polarized right electrode generates a cation-rich EDL. Hence, anions on top of the left electrode moves opposite to the electric field direction and cations on top of the right electrodes drift along the direction of electric field. During the second half of the AC signal (Fig. 11b), the left electrode becomes negatively polarized and right electrode gets positively polarized. This polarity change reverses the electric field direction as well as the dominant type of ions on both electrodes causing movement of ion in the left direction on the left electrode and towards the right direction on the right electrodes. In other words, in both half cycles, the direction of ion movement remains the same. This ion movement carries surrounding fluids owing to the viscous drag. AC electroosmosis requires much lower voltage than DC electroosmosis, which is one of the major advantages of this technique. Moreover, the effect of AC electric field can be controlled by the waveform, peak to peak voltage and the frequency of the applied electric potential.
Although there are many similarities between AC and DC electroosmosis, there are some significant differences between them. For instance, in AC electroosmosis, electrodes are responsible for both creating the electric field as well as forming the EDLs. In regular or DC electroosmosis, the channel surface charges actively participate in the EDL formation, and the surface charge density is much lower than in AC current supplying electrodes patterned on the channel surface. Thus, the mechanism for the electric double layer formation is quite a bit different in AC electroosmosis, which is discussed in Section 2.2.
The general governing equations for fluid velocity and electrostatic potential are same as in DC electroosmosis. Thus, we briefly review the boundary conditions for electric potential as well as for the flow field in the following section. Ramos and coworkers [106] presented the mathematical model to study the AC Electroosmosis considering the thin double layer and linear double theory. Later, Kilic et al. [32] extended the theory for the nonlinear electrokinetics, where the potential difference across the electric double layer is much larger than the thermal potential. AC electroosmosis takes place when the applied electric field frequency is much smaller than the charge relaxation frequency of the bulk electrolyte fc = σ/2πε. At this low applied electric field frequency range, the EDL is in quasi-equilibrium. Under this assumption, the EDL goes through capacitive charging, while the bulk of the electrolyte behaves in a resistive manner. Thus, one can model the fluid domain with Laplace equation (can be deduced from Eq. 11), but with appropriate boundary conditions. At the channel surface, such as in the glass, PMMA, or PDMS, an electrically insulating boundary condition is valid. However, at the electrode surface, the boundary condition is slightly more complicated due to EDL formation. It is not possible to apply a Dirichlet boundary condition. The reason is that at low frequencies the EDL will go through capacitive charging and there will be a potential drop across EDL.
The charging of the double layer due to bulk current can be expressed as [107]
(27) |
where qDL = CEDL(ψ – Ve) and CEDL is the capacitance per unit area of the electric double layer (both Stern and diffuse layer), Ve is the potential applied to the electrode, and ψ is the electric potential at the outer side of the diffuse layer. This linear relationship is valid for a small potential difference across the electric double layer. The double layer capacitance can be found from
(28) |
where CS and CD are the Stern and diffuse layer capacitance. The capacitance of the Stern layer is generally independent of the ionic concentration of the solution. The capacitance of the diffuse layer can be found as [32]
(29) |
where ψD is the diffuse layer potential. Kilic et al. [32] presented expressions for the diffuse layer capacitance considering the different level of double layer charging based on the applied electric potential as.
where υ is the volume fraction occupied by ions in the bulk fluid.
AC electroosmotic flow velocity can be obtained from the solution of the Navier-Stokes and continuity equations by neglecting the inertia term. The inertia term consists of the transient term as well as the advective term. The transient term can be dropped since the time scale for fluid to respond to an applied AC electric field is much smaller than the applied electric field time scale. For instance, the typical electric field frequency used for AC electroosmosis is 10-100 kHz, while the typical response time for fluid in AC electroosmosis is in milliseconds. The advective term can be dropped because of the fact that the flow velocity is very small in an electric field driven micro/nanochannel flow. The typical Reynolds number for microflows is much smaller than 0.01. Thus, the simplified governing equations for AC electroosmosis are
(30) |
(31) |
These flow equations can be solved with no-slip and no-penetration boundary conditions at the channel and electrode surfaces, and periodic boundary conditions at the appropriate symmetry planes. In this general formulation, one has to find the forcing term throughout the computational domain. Like DC electroosmosis, for incompressible flow with a homogeneous fluid, the predominant forcing term is Coulombic. However, the computation of the Coulombic forces requires detail modeling of the EDL for electric potential distribution. One alternative approach is to solve the flow equations without the forcing term, but with an appropriate electroosmotic slip velocity at the electrode surfaces. For AC electroosmotic, the required slip velocity at the channel surface can be given as
(32) |
where φ̃ is the complex electric potential at the inner side of the diffuse layer, and is the tangential (complex) electric field. In linear regime [107], capacitances and electric potential can be related by
(33) |
Using Eqs. (32) and (33), the time-averaged AC electroosmotic velocity can be obtained as
(34) |
where Re[] is the real component and is the complex conjugate of the electric field.
5.1 ACEO as Pumping Mechanism
In ACEO pumps, an electric field is applied through microelectrodes patterned on the channel surface. Generally, symmetric coplanar electrodes are used for this type of pumping as shown in Figure 12a. Figs 12(b-d) illustrate the experimental work of Green et al. [108], where they studied the effect of applied electric potential magnitude and frequency in pumping KCl solution of different conductivity: Fluid A - 2.1 mS/m, Fluid B - 8.6 mS/m, and Fluid C: 84 mS/m. Flow velocity was measured with fluorescent tracking particles under microscope and images were recorded. Their experimental results show that the ACEO velocity increases with frequency and reach to a peak value before decreasing with frequency. ACEO reaches to a negligible value at a frequency known as charge relaxation frequency. Thus, for AC electroosmotic flow, the applied frequency range should be smaller than the charge relaxation frequency so that the EDL can form on top of the electrode surface. In addition, they observed that flow velocity decreases with the conductivity of the fluid indicating that the AC electrothermal velocity is negligible for the frequency range considered in their work. Similar planar electrode based ACEO pump was reported by other researchers [109, 110] to name a few. Urbanski et al. 2007 [111] developed 3D ACEO pumps based on nonplanar electrodes with variable heights. They demonstrated that nonplanar ACEO pump can produce fast fluid flow compared to planar ACEO pumps.
Although symmetrical electrodes are popularly used to create AC electroosmotic flow, ACEO pumping with symmetrical electrodes cannot create a flow in a preferred direction. In fact, this type of symmetrical electrode configuration creates a circulating motion in the vicinity of an electrode in the form of vortices. Ajdari [112] first theoretically predicted that the asymmetry of electrodes array can be used to drive fluid in a certain direction for pumping liquid in microfluidics. In their theoretical work, they have demonstrated asymmetry by modifying the surface charge characteristics of electrodes in addition to electrode/channel surface topology. Later, Mpholo et al.[113], Brown et al. [114], Ramos[115] and others experimentally demonstrated pumping of fluid using asymmetric electrodes in the microchannel.
Figure 13 shows the electrode arrangements for an AC electroosmotic pumping with an asymmetric electrode array. The asymmetric electrode array consists of wide electrodes (E1), narrow electrodes (E2), narrow gaps (G1) and wide gaps (G2) between electrodes. In order to break the symmetry, the width of the narrow electrode should not be the same as the width of the wide electrode. In addition, the gaps G1 and G2 should be different [116]. Ramos et al. [115] studied the asymmetric ACEO numerically where they have shown fluid flow is always in one direction, but the experimental work from the same group for the identical microfluidic setup was not conclusive [117]. For instance, outside the vortices region, they obtained flow from the right to the left direction for low applied electric potential, but their flow direction reverses at high applied electric field direction (not shown). Pure AC electroosmotic phenomena with the linear voltage drop across the double layer cannot be used to justify the flow reversal at the high applied AC potential, and some other electric field driven mechanism might be responsible. Storey et al. [118] identified the steric effects, overcrowding of ions due to the large induced voltage across the double layer, related decrease in surface conductance as the primary reason for flow reversal even at the low bulk salt concentration case. Nevertheless, the average flow velocity obtained in both high and low electric field cases are negligible for any useful pumping in a preferred direction.
To improve the pumping ability of ACEO pump, Huang et al. [119] presented an ACEO pump with stepped electrode arrays, and they compared their design with a traditional asymmetric coplanar electrode ACEO micropump. Their pump could generate a pressure 1.3 kPa at 1 Vrms and 1 kHz, which is two orders of magnitude higher than the previously reported ACEO micropumps. Although the stepped design presented in their work was able to improve the pumping ability significantly, it is paltry for any useful pumping in a microfluidic device. In other words, AC electroosmotic phenomenon cannot be used as a standalone global pumping technology, rather it can be employed as a local control mechanism since it creates highly nonuniform velocity, which is responsible for vortices. Researchers combined the ACEO local pumping with other phenomena such as dielectrophoresis [120], light activated phenomena [121], pressure driven flow, etc. for separation, concentration, manipulation, and sensing. For instance, ACEO pumping is combined with dielectrophoresis for the collection of cells [122] and particles [123], separation of colloids [124], rotation [125] and manipulation [126] of particles in a microfluidic chip. Similarly, by combining with other microfluidic-based actuation technique, ACEO pumping is used for separation and concentration [127-130] and detection [131-134].
6. AC Electrothermal
AC electrothermal effect is caused by the interaction between the applied electric field and space charges created by the temperature gradient driven conductivity and permittivity variations. Like ACEO, generally co-planar electrodes are used for creating ACET flow. The non-uniform electric field generated by the coplanar electrodes can generate spatially varying heat sources in the fluid domain, which in turn causes nonuniform temperature distribution in the system. Since the fluid properties, such as density, viscosity, electrical conductivity, and permittivity are a function of temperature, non-uniform temperature field will create a permittivity and density gradient, and these gradients will contribute to the forcing term, in addition to the Coulombic force. Like EO and ACEO, the electrostriction term is negligible for ACET flow. Thus, the total forcing term (per unit volume) can be expressed as a superposition of electrical and buoyant force.
(35) |
where ρr is the reference density and g⃗ is gravitational acceleration.
Since AC electric field is used in ACET, the computation of electrical forcing term requires the solution of the complex electric field, which is computationally expensive. Ramos et al. [25, 36] have introduced an alternate method for calculating flow field in ACET using some reasonable approximations. For instance, it is assumed that the electric double layer is very thin and the bulk region is electrically neutral. In their analysis, the total electric field E⃗ is decomposed into two components, E⃗0 and E⃗1, where
(36a) |
(36b) |
Using aforementioned relationship, the electrokinetic body force term can be approximated as
(37) |
Similarly, the free charge density can be rewritten as
(38) |
To find the electrokinetic forcing term, one has to find both E⃗0 and E⃗1. Fortunately, E⃗0 = −∇ψ0 can be found from the solution of
(39) |
Substitution of the free charge density and electric field in the charge conservation equation (Eq. 13) yields
(40) |
In AC electric field, the time-dependent electric field is presented in terms of a complex number. Thus, the charge conservation equation can be rewritten as
(41) |
One can use the relationship presented in Eqs. (36) to simplify the charge conservation equation as
(42) |
Finally, an equation for the divergence of perturbation electric field E⃗1 can be obtained from the rearrangement of Eq. (42)
(43) |
Substituting Eqs. (38) and (43) on Eq. (37) provides an expression for the AC electrothermal flow as
(44) |
The timescale for the fluid to response under an AC electric field is much slower than the applied electric field frequency. Thus, a time average forcing term can be applied to the flow equation. For the AC electrothermal flow, the time averaged electrical forcing term can be rewritten as
(45) |
The AC electrothermal flow can be obtained by solving Eqs. (30) and (31) with a time averaged forcing term given in Eq. (45). In case of the electrothermal process, the electric field for the forcing term can be obtained from the Eq. (39), with appropriate boundary conditions at the electrode. The electric field is applied on the metallic electrode surface. Under thin double layer assumption, the applied electric field can be connected with the bulk electrolyte potential by the charge conservation equation. In thin double layer, the lateral current due to advection or diffusion is much smaller than the normal current [36]. Thus, like ACEO process, the charge conservation can be expressed as a balance between charge storage rate in the double layer and the normal current as presented in Eq. (27), and the boundary condition for the electric potential can be deduced as [36]
(46) |
6.1 ACET Pumping in Microchip
The first known work on the electrothermal micro pumping was reported by Fuhr et al. in early 1990, where they observed the flow of low conductive distilled water in a microfabricated channel. In their work [28], a four-phase traveling wave electric field is used to drive fluids in which an array of electrodes (10 microns wide and 10 microns gap) attained a peak velocity of ∼180μm s-1 at 35 Vpp and 100 kHz with fluid conductivity 9.3 mS m-1. This demonstration showed practical possibilities of producing relatively high fluid velocity using a non-uniform electric field, which might be useful for micro pumping in the biomedical field. Sigurdson et al. [135] demonstrated the application of ACET effect to induce vortices in a pressure driven flow system to improve the binding rate of ligands in an assay. In their work, they have shown the transport of fluid in diffusion-limited reaction, where the binding rate factor is increased by seven when compared to conventional binding process. Later, Lian et al. [26] demonstrated AC electrothermal pumping of conductive liquids with an applied voltage level less than 25 V, and they claimed to achieve a local fluid velocity up to 80 μm/s. The same group also used a T-shaped electrode design to pump biofluid [136]. Using interdigitated coplanar electrodes, Koklu et al. [137] presented a parametric map for electrothermal vortices within the physiological conductivities considering the different size of channel heights.
Recently, Lu et al presented a design for long-range fluid motion induced by ACET [42]. Figure 14a shows the schematic of such a microdevice, where electrodes are formed on the bottom (glass substrate) layer, while the three other sides of the channel consist of PDMS. Their study has shown vortices that can span more than one centimeter (Fig 14b) if the channel height is in the order of a millimeter. On the other hand, smaller dimension microchannels (less than 300 microns) provides smaller counter vortices close to the electrode. They also developed a comprehensive computational model, which considers the buoyancy effects due to density gradient and temperature-dependent parameters. Their experimental results are in good agreement with numerical data if (i) buoyancy effect is considered, (ii) temperature dependent fluid properties are used, and (iii) a Robin type boundary condition is implemented for the temperature equation. Their extended numerical model also identified some major shortcomings of the general scaling law. For instance, their experimental data disagree with the claim that the local electrokinetic velocity is proportional to the fourth power of the applied voltage, especially for highly conductive biofluid. Loire et al. [138] also emphasized the role of buoyancy/natural convection forces on the electrothermal studies, which were predominantly ignored in many classical electrothermal theoretical works.
Since ACET takes place in a non-uniform AC electric field due to the conductivity gradient (spatial difference in conductivities) driven local temperature distribution resulted from the nonuniform Joule heating, a number of researchers tried to supplement the conductivity difference in the buffer furthermore using other innovative techniques. Perhaps, the most common choice to achieve this goal is to heat the microchannel and create an artificial temperature gradient [139]. Yuan and Wu [140] have demonstrated this thermally biased AC electrokinetic pumping by selectively heating one electrode, while maintaining the other electrode at room temperature. They have reported a significant improvement in the ACET flow velocity due to selective heating of one electrode, though their results were presented for very low applied electric potential. Recently, Williams and Green [141] presented the effect of external heating on the flow performance for AC electrothermal flow, where the heating elements were electrically isolated from the electrodes used for AC electric field. They have studied the effects electrode arrangement, size, and gap between electrodes using a numerical model.
Another innovative way to create the conductivity gradient is by strong illumination [142], microwave or laser heating. Green et al. [143] have shown the effect of light in the AC electrothermal flows by illuminating one electrode region, while keeping the other electrode at dark. They have noticed that the direction of fluid flow changes with frequency, though they still maintain counter-rotating vortices. Later, they presented a self-similar solution to explain some of the experimental observations quantitatively [144]. Kwon and Wereley [142] have demonstrated rotationally symmetric vortices in light actuated electrothermal flow, where electrodes were formed on the top and bottom surfaces of a parallel plate microchannel; and conductivity gradient was enhanced by shining laser light on the top and bottom electrodes. Their study also emphasized the role of buoyant forces for the cases when the applied electric field frequency is above the charge relaxation frequency.
Conductivity difference in the buffer can also be created by maintaining a DC bias to AC signal on symmetric planar electrodes formed on the microchannel surface. Figure 15 shows the schematic of the negative and positive DC-bias AC electrothermal systems [145] used for pumping. In Fig. 15a, the right electrode is set as a net negative electrode, while the left electrode is as a net positive. Due to electrochemical reactions at the electrode-electrolyte interface (aka Faradic reactions), co-ions are produced and released on the electrolytes. Thus, for the negative DC-bias case, cations are produced on the net positive (left) electrode, while anions are gathered on the right electrodes as seen from Fig. 15a. These anions and cations are responsible for setting up different pH -- acidic on the cationic side and basic on the anionic side.
Ng et al. [145] reported the formation of acidic and basic domain due to the release of ions from the electrodes, and these additional ions alter the conductivity of the solution. For instance, from their experimental work, high conductivity is observed for the net negative electrode and low conductivity are found for the net positive electrode, causing a conductivity gradient along the channel. Under the action of an AC electric field, fluid is moved from the higher conductivity region to the lower one creating clock-wise vortices next to electrodes. Similarly, in Fig. 15b, the electrode setting is just opposite of the Fig. 15a, and anti-clockwise fluid vortices are obtained as shown in Fig. 15d.
Like ACEO flow cases [146], asymmetrical electrode configurations were also explored in ACET flow. Vafaie et al. [147] presented so-called discretized electrodes for forward and backward pumping using asymmetric electrode configurations and switching of electrodes for positive and negative potentials. Asymmetrical electrodes configuration is used to create AC electrothermal flow to improve the binding reaction efficacy in a microchannel immunoassay [148]. Wu et al. [149], demonstrated the ACET flow driven vortex in a micromixer, where the fluid flow is created by 3D electrodes imprinted on the channel side wall. Salari et al. [150] developed an electrothermal micropump by placing asymmetrical electrodes on all sides of the microchannel. Lang et al. [151] used thirty pairs of asymmetrical electrode arrays to develop a close loop electrothermal micropump to grow human embryonic kidney cells and human colon carcinoma cells in a microfluidic chip.
Although there is a significant interest in AC electric field driven fluid motion in microdevices using ACEO and/or ACET, none of these methods were able to create a pressure gradient for a sustained net flow like DC electroosmotic pumps. Also, working with ACET for high conductivity fluids is not very desirable for the biological sample as excessive temperature rise happens in highly conductive biofluid especially close to the electrode, which may damage the biological activities of samples. Thus, extreme care must be taken to adopt this technology for highly conductive biological buffers or proteins.
7. Induced Charge Electroosmosis (ICEO)
When an electric field (AC or DC) is applied to a polarizable post or an object embedded in an electrolyte, a dipolar charge is induced leading to the formation of a dipolar double layer as shown in figure 16b [30]. Due to the formation of the dipolar double layer, the applied electric field becomes tangent to the surface of the post or object, and causes an electroosmotic flow which is known as induced charge electroosmotic (ICEO) flow (figures 16c & d) [34]. ICEO flow is observed both around the neutral polarizable object as well as the charged polarizable object [152-154]. ICEO phenomena are especially important at the smaller zeta potential [30]. Bazant and Squires demonstrated that when total zeta potential (initial + induced) ζ is much smaller than 2(kT/e)log(L/ λD), ICEO dominates over other electrokinetic effects. Otherwise, nonequilibrium electrosurface phenomena (NESP), second kind electrokinetic phenomena etc. dominates [155-157].
Like DC and AC electroosmosis, induced charge electroosmosis (ICEO) is a consequence of the interaction between the electric field and electric double layer. However, ICEO is different from other electroosmosis due to the nature and formation of the double layer from the surface electric conditions. In regular fixed charge or classical DC electroosmosis, zeta potential remains uniform throughout the material as an equilibrium surface property. In contrast, the zeta potential is induced in ICEO by the applied electric field due to charge accumulation, which is non-uniform and dipolar in nature. Squires and Bazant [30] provided the detailed theoretical analysis of ICEO for various conditions based on the thin double layer (λD ≪ r0) and weak applied electric field (E0r ≪ kBT/ze) approximation. In the following section, we briefly reviewed their theoretical model.
When an electric field (E0k̂) is applied to an uncharged conductive cylinder of radius r0 immersed in an electrolyte solution (Fig. 16a), the electric field lines intersect at a right angle on the cylinder and form an equipotential surface with an electric potential of ϕ0, which is given by [34]:
(47) |
In the absence of electrochemical reaction, ions in the electrolytes move toward the cylinder and form dipolar screening of ion clouds around the cylinder surface. The formation of screening ion cloud facilitates a time-dependent induced zeta potential around the cylinder surface. The time-dependent zeta potential can be obtained from surface charge density (q), applied electric field and electrolyte conductivity (σ) as given by [30]
(48) |
where ε is the permittivity of the electrolyte solution, κ−1 = λD is the Debye screening length and r̂ is the unit vector in the radial direction. The system eventually reaches to steady state configuration when the formation of the dipolar double layer around the cylinder is complete and expels all electric field lines i.e. electric field lines become tangent around the cylinder surface ion-cloud, leaving no normal component as shown in Fig. 16b. The tangential component of electric field is obtained as follows
(49) |
At this configuration, the electric potential outside the screening cloud can be expressed as
(50) |
Thus, the spatially non-uniform zeta potential around the surface can be obtained as follows [30]
(51) |
The tangential component of applied electric field acts on the EDL formed by the nonuniform zeta potential and causes induced charge electroosmotic flow (ICEO). The ICEO slip velocity around this cylinder is found from classical Helmholtz-Smoluchowski formula as follows
(52) |
where U0 is the order of velocity scale for ICEO, which can be presented as
(53) |
ICEO velocity is stronger than regular electroosmosis since it depends on the square of the applied electric field. For a charged cylinder as shown in figure 16d, i.e. cylinder with a non-zero equilibrium charge density, , the steady state zeta potential distribution has both constant uniform zeta potential and induced non-uniform potential as follows
(54) |
Hence, the ICEO slip velocity for a charged cylinder will be a superposition of slip velocity due to constant equilibrium zeta potential and slip velocity due to induced non-uniform zeta potential as shown in Eq. (52) as given by [30]
(55) |
For time-dependent ICEO, the slip velocity for charged or uncharged cylinder, Janus particles, insulating or conducting post can be found in [30, 158-160]. ICEO can also be obtained in an AC electric field. The governing equations for ICEO include Maxwell's equation, charge conservation equation (Eq. 15) and fluid flow equation (Eqs. 16-17). For typical microfluidic ICEO, the Navier Stokes equations reduces to Stokes equations because of the assumption mentioned in ACEO section.
7.1 ICEO as Pumping Mechanism
At the early stage of theoretical development of ICEO phenomena, the primary focus was on the flows around polarizable cylindrical posts in a uniform electric field where a quadrupolar flow can be obtained as seen in figure 17. Later, Bazant and Squires demonstrated that the ICEO can be used to drive fluid flow in any direction by designing and breaking the spatial symmetry of conducting posts relative to the background AC or DC electric field [160]. The spatial symmetry on the conducting post can be broken by dielectric or conductive coating or by optimizing the shape and topology of the posts to control ICEO flow [159, 161, 162].
Squires and co-workers demonstrated ICEO micropumps using arrays of Janus metallo-dielectric micropillars [163]. Unidirectional ICEO flow is obtained upon application of AC electric field across the channel length by breaking symmetry with the Janus micropillars. The schematic of the micropillars array, as well as other control mechanisms used in their study, are shown in figures 17a-d. The microfluidic ICEO pump was tested with seven different electrolytes (2 strong and 5 weak electrolytes) solutions, and the pK values of solution were varied by varying buffer composition for evaluating the effect on the ICEO velocities. The operating applied AC potential on the driving electrodes was varied between 100 and 175 VPP and frequencies between 1 and 20 kHz. Fluid velocities, measured using microPIV, were observed on the low-pressure side of the channel loop. The pump pressure was measured for various combinations of electric field strengths and frequencies as well as electrolytes as shown in the figure 17g. The lowest pressure was found to be 15 Pa for 100 μM KCl and the highest pressure was 150 Pa for 100 μM Tris buffer. They have reported that the pump pressure varies with applied potential as Δp∞φ0–2 depending on the frequency, type of electrolyte and applied voltage.
Breaking symmetries of ICEO flow through irregular shaped posts, non-uniform surface properties, controlled potential and field gradients etc. are the key for producing streaming flow in this type of micropump [159, 160]. Recently it is reported that ICEO flow increases with the increasing concentration of NaCl and KCl [164], but it was previously considered that the ICEO velocity decays with increasing concentration in general [158, 165]. ICEO pumping velocity and mass flow rate are also dependent on the size and relative orientation of circular posts [166, 167]. Gregerson et al [159] developed a mathematical model for shape and topology optimization to improve the pumping capability of ICEO micropumps.
8. Dielectrophoresis
Dielectrophoresis (DEP) is widely used for movement of polarizable particles in fluid media under the action of a nonuniform electric field [168]. DEP mechanism is classified based on the nature of electric field, such as AC DEP, DC DEP, traveling wave DEP etc. Depending on magnitude and direction of the applied electric field, dielectrophoretic force can create movement of particles in a preferred direction. In a densely populated particulate system, the particle movement can cause a fluid flow and it is reported to use as a pumping mechanism in microfluidics [169, 170]. The various mechanisms for DEP base fluid pumping are described in the following sections.
8.1 Traveling wave Dielectrophoresis (twDEP)
Traveling wave DEP is created for movement of particles in a preferred direction by imposing phase differences in the applied AC electric potential on electrode surfaces. Like ACEO or ACET, planar electrodes are used for the creation of AC electric field, but the phase difference between consecutive electrodes are not set at 180°. Figure 18(a) shows a schematic of a traveling wave DEP system, where continuous phase differences in the applied AC electric potential is achieved through a series of microelectrodes. The delay in phase differences at different electrodes creates a moving electric field gradient which either attracts suspended particles in the direction of propagation or drives away particles in opposite direction of electric field propagation. The movement of sufficiently dense particles induces flow and entire fluid domain moves with the same direction of particles motion [28].
In case of an electric field driven particulate flow, the time scale of particle motion is usually much smaller than that of the electric field. Hence the electrostatic potential distribution for particulate flow is obtained from the quasi-electrostatic model. In the quasi-electrostatic model, the Maxwell equations can be reduced to Eqs. (8-10).
In pure DEP, charges are the major current carriers and the effects of ionic current are negligible. For a linear, isotropic and homogeneous medium, the current density due to the inherent carrier can be given as J⃗ = σE⃗, and the charge conservation equation (Eq. 13), can be rewritten as
(56) |
Now, the time derivative of Eq. (11) and a complex variable presentation of electric potential ψ̃(r⃗,t) = ψ0(r⃗)ejωt yield
(57) |
Substitution of Eq. (57) in Eq. (56) gives
(58) |
Alternatively, the above equation can be written as
(59) |
where the complex permittivity can be given as .
The electric potential distribution for twDEP is obtained by solving Eq. (59) for both fluid and particle domain. This requires proper boundary conditions as well as interface conditions between particle and fluid interface. The typical boundary conditions are as follows:
(60) |
(61) |
The continuity of the electric potential and the normal component of the electric flux density are imposed as interface conditions between particle and fluid interface as:
(62) |
(63) |
where subscript p is for the particles, f is for the fluid media and n⃗ is the surface normal. The volumetric dielectrophoretic force is calculated from the time-averaged Maxwell stress tensor by integration over the period of the AC electric potential. Hence the time-averaged dielectrophoretic force density on the particle surface can be given by [171]
(64) |
where is the conjugate of , is the unit tensor, is the dyadic product of electric field and its conjugate.
Although Maxwell's stress tensor-based estimation of DEP force is considered as the most accurate method, it requires the solution of complex electric potential (ψ̃(r⃗,t)) in a fluid domain embedded with particles or posts. The computational process of Eq. (59) is very challenging and it requires interface-resolved sophisticated numerical methods with high computational cost [37, 172]. Fortunately, there exists an alternative approach to evaluate DEP force based on the effective dipole moment method. In this method, particles are considered as point charges and the effect of polarization is accounted through the dipole moment. In this simplified case, the electric potential distribution is estimated by solving Laplace equation (Eq. 39) in the fluid domain without considering the presence of particles. Wang et al. [173] presented a unified effective dipole moment based force expression as
(65) |
where p⃗(r⃗,t) is the induced dipole moment, px, py and pz are components of induced dipole moment in x, y and z-direction of Cartesian coordinate, and the AC electric field can be expressed as
(66) |
where î, ĵ, k̂ are the unit vector in Cartesian x, y, z coordinates, respectively, Ex(t) = E0x(x, y, z)cos[ωt + δx(x, y, z)], Ey(t) = E0y(x, y, z)cos[ωt + δy(x, y, z)], Ez(t) = E0z(x, y, z)cos[ωt + δz(x, y, z)] and E0x, E0y, E0z are the magnitudes of electric field, δx, δy, δz are the phases of electric potential in x, y, z direction. Using superposition principle, Huang et al. [174] derived an expression for dipole moment as follows
(67) |
where χCM =(ε̃p – ε̃f)/(ε̃p + 2ε̃f) is the Clausius-Mossotti factor. Since typical AC frequencies in DEP is below 100 MHz, it satisfies quasi-electrostatic approximation. Hence and using Eqs. (65) and (67), the generalized DEP force in the x-direction is given by [174]
(68) |
The time-averaged generalized DEP force component in x-direction is obtained from above equation as follows
(69) |
Similarly, the time-averaged component of generalized DEP force in y and z-direction can be obtained. The effective dipole moment based generalized DEP equation is given by [173]:
(70) |
where the first term represents the spatial nonuniformity of applied electric field which is relevant to the conventional DEP force, and the second term represents spatial phase distribution to account the effect of the traveling wave. The second term goes to zero for conventional DEP since the electric field is phase independent.
The particles move toward the positive gradient of the electric field when Re (χCM) is positive and vice versa. On the other hand, the particles move along the propagating direction of the traveling wave when Im(χCM) is positive and against the propagating direction of the traveling wave when Im(χCM) is negative. The maximum effect of twDEP is observed near the Maxwell-Wagner relaxation frequency,
(71) |
8.1.1 Travelling Wave DEP for Microfluidic Pumping
Unlike a fixed electric field minima or maxima in conventional DEP, traveling wave DEP creates a moving point of attractions i.e. moving electric field minima or maxima for particles so that particles can be continuously transported in a certain direction. The second term of Eq. (70) should be large enough so that it can overcome fluid drag force as well as a component of the first term of Eq. (70) which acts against this (second) forcing term [175]. These forces can be optimized for a continuous flow by regulating the electrical properties of fluids and suspended particles, applied electric field strength, and frequencies (Table 2).
Table 2. Comparisons of various travelling wave dielectrophoretic pumping.
Author and Year | velocity | Applied Voltage | Pumping Fluid |
---|---|---|---|
Fuhr et al[28]. 1994 | 190 μm/s | 35 V | Aqueous solution with suspended latex microparticles |
Hagedorn et al[29]. 1992 | 600 μm/s | 12 V | Water with suspended microsphere |
Masuda et al. 1988 | 10 μm/s | 1.5 V | Sucrose solution with suspended erythrocytes |
Pethig et al[175]. 2003 | 64 μm/s | 1.06 Vrms | Monocytes cells suspending in glucose, sucrose solution |
Tseng et al[176]. | 25 μm/s | 5.5 V | Red blood cells suspending in glucose, sucrose solution |
Wang et al[177]. 2011 | 4.2 μm/s | 2 V | Red blood cells suspending in glucose, sucrose solution |
Lei et al[178]. 2009 | 15 μm/s | 15 V | Red blood drops |
Lei et al. [178] demonstrated microfluidic blood delivery using the twDEP pump, where an array of microelectrodes is deposited at the bottom of the glass-PDMS rectangular microchannel. They applied an AC potential (3 to 5 V) with a frequency range from 1 to 40 MHz and phase shift of 90° or 120° between neighboring electrodes (repeats in every 4th electrodes) to create a significant variation of conventional and traveling wave DEP forces.
Figure 19a shows the variation of non-dimensional conventional and traveling wave DEP forces at the half of the channel depth. The twDEP forces are positive in the region of electrodes and decay rapidly beyond the electrode regions. On the other hand, the conventional DEP force is weaker in the electrode region and stronger near the reservoir. This observation is in line with the previous experimental findings of Hughes [179] where it was reported that the conventional DEP force is higher than the twDEP force within 5 μm of the reservoir. Near the reservoir, the conventional DEP force works against the twDEP force. However, because of the stronger twDEP force over electrode region, blood cells are pushed forward and a lower pressure is created at the upstream compared to the downstream region. The motion of blood cells causes a continuous flow, and the flow velocity was measured using microscale particle image velocimetry – microPIV. The velocity of cell within the microchannel is shown in figures 19(b -d) as a function of applied frequency and number of electrodes, respectively.
Their experiment reveals that the velocity increases as the peak to peak applied voltage increases (not shown here). They have reported a minimum peak to peak voltage of 3 V for pumping, and blood cells were damaged at 6 V. There is an optimum frequency for which the pumping velocity reaches its maximum depending on the phase lag. For their experiment, the optimum frequency is 20 MHz and 30 MHz for a phase difference of 90° and 120°, respectively. It is also reported that the average velocity increases with the increase in the number of electrodes due to stronger twDEP force.
Application of traveling wave electric field can also facilitate other types of electrohydrodynamic pumping [180]. He and Liu [181] presented the effect of electrohydrodynamics on twDEP pumping. Recently, multifluid mixing and pumping [182], modulation of blood flow in microchannels [177], separation and transportation of cells etc. are demonstrated where twDEP is used as a primary fluid driving mechanism [183, 184]. Tseng et al. [176] designed and developed a driving circuit that can efficiently replace function generator for steady state twDEP pumping of blood sample in a microchannel.
8.2 Liquid Dielectrophoresis (LDEP)
Liquid dielectrophoresis (LDEP) is defined as the motion of liquid in an air-liquid interface or bubble within a liquid due to the application of a non-uniform AC or DC electric field [185, 186]. The fundamental working principle of LDEP is shown in figure 20. When a non-uniform electric field is applied in a liquid-air interface or liquid-bubble mixture, polarization takes place. In case of a liquid-air interface (Fig 20a), dielectric liquid is drawn to the higher intensity electric field since it is more polarizable than the gas. On the other hand, for the liquid-bubble mixture (Fig. 20b), gas or vapor bubbles are driven away from higher intensity electric field. Like ACET, LDEP is distinct from many electrokinetic mechanisms, where flows are primarily originated from the ion-drag effect or electroconvection.
There are some similarities between LDEP and electrowetting as LDEP can be used to move liquid from a droplet using a pair of electrodes. However, unlike electrowetting, in LDEP the electric field lines penetrate through the liquid and control the shape of the liquid front that moves between electrodes [187]. Usually, the contact angle of LDEP is higher than the electrowetting. LDEP can be used to move conductive liquid too using an AC current. In case of conductive liquid, the microelectrodes have to be coated with a very thin dielectric layer and liquid pumping depends on the applied frequency of AC electric field and the thickness of dielectric layer [187]. If the applied frequency is greater than the crossover frequency, the conductive liquid behaves like a dielectric liquid, and in that case, the conductive fluid is driven like a moving finger front. On the other hand, conductive fluid cannot be moved using a frequency lower than the crossover frequency. In that case, fluid just spreads on the substrate as shown in Fig. 21c.
If a liquid is placed between two energized electrodes as shown in figure 21a, the electric field induced force acts on the interface between liquid and gas to facilitate motion of the liquid. This interfacial force is found from Kelvin-Helmholtz formulation [46, 188] as follows:
(72) |
The similar formulation is obtained from Maxwell's stress tensor as discussed for equation (19). For an uncharged and incompressible liquid, the first and the last term of right-hand side of the forcing equation can be neglected. At the interface, the DEP force (the second term in the equation 72) can create a hydrostatic pressure difference between liquid and gas, which is similar to capillary force at the curved surface [185]. Thus, the hydrostatic pressure difference at the interface can be obtained [185] as
(73) |
However, strictly speaking, the LDEP is not a pumping mechanism. Nevertheless, it can provide a flow of liquid or bubbles in a way similar to the fluid flow in the capillary tube through capillary action or surface tension. In LDEP literature, the height rise of the liquid between narrowly spaced electrodes is calculated based on Pellet's classical experiment [189] as
(74) |
The liquid dielectrophoretic pumping mechanism is also mostly modeled with simplified Maxwell's equation for electric field and Navier Stokes equation (Eqs. 16-17) for fluid flow. However, for simplicity, it is reported to use phase-field formulation to describe LDEP mechanism. In phase field formulation, the air and liquid volume are treated as one fluid domain with varying physical properties (such as density, viscosity, electrical permittivity, and conductivity) across air-liquid interface [190]. The driving force in liquid dielectrophoresis can be calculated from Eq. (19). However, for dielectric liquid, ρe = 0 due to an absence of free charge in the liquid and first term on force expression in Eq. (19) can be neglected.
8.2.1: LDEP as Pumping Mechanism
Pan et al. [191] demonstrated DI water pumping in a microchannel for various channel configurations using LDEP. In their experiment, DI water (as pumped liquid) was surrounded by silicon oil (as a low dielectric medium), and the mixture is placed between plates as shown in figure 22a, where the top plate contains blank electrode and bottom plate contains patterned electrodes. The path of water flow is defined by the patterned electrode, which is covered with a dielectric coating. Spacers of different depth were placed on the bottom glass slides to hold liquid of different depth depending on the experimental conditions. The DEP force that drives the liquid depends not only on the applied electric potential, but also on the width of patterned electrodes and depth of flow stream [192]. Figure 22c shows the water stream flowing over the bottom electrode and forming a virtual microchannel. Pumping velocity of water flow in the virtual microchannel was measured by observing the advancement of the water meniscus. The pumping velocity depends on the applied voltage and aspect ratio (d/w) as shown in figure 22d. It has been shown that the pumping velocity can be reached as high as 27 mm/s by modulating aspect ratio and applied voltage for 100 kHz AC signal. Their group also demonstrated liquid flowing over wide varieties of electrode designs [191].
Renaudot et al. [193] reported optimization of LDEP devices that can operate as low as 150 Vrms between electrodes with 4 μm gap for a liquid having conductivity up to 10 mS/m. LDEP was also used to flow sucrose solution to transport HeLa cell in a microchannel to demonstrate DEP trap and release mechanism [194]. Moreover, LDEP has been reported to use in the transportation of free-floating droplets [195], continuous gas pumping without leaking [196], and liquid actuation on superhydrophobic surfaces [197]. For more information on this micro pumping technique, readers are suggested to consult the detailed review of Kaler et al. [198] and Jones [185].
9. Concluding Remarks
Electric field driven pumping mechanisms are popular in microfluidics since they do not require mechanical moving parts, which make them more compatible with micro-total-analytical systems (μTAS) or lab-on-chip format. This review article provides a systematic description of various electrokinetic phenomena used for micro pumping with detailed physics, unified governing equations, related boundary conditions, and scaling laws. Table 3 shows the comparisons of different electric field driven pumping mechanisms. Depending on the choice of fluid medium, electric field and substrate, one or more phenomena can drive fluids. In some scenarios, one or more phenomena need to be suppressed through design parameters for better control and efficient pumping. Based on the rigorous analysis and literature review presented above, following conclusions can be drawn:
Table 3.
Ion Drag (EDL formation) | Thermal Effect | Particle Polarization | ||||
---|---|---|---|---|---|---|
DCEO or EO | ACEO | ICEO | ACET | twDEP | LDEP | |
Required conditions for flow in micro/nano-channels | Spontaneous EDL formation due to fixed charge on channel surface | Periodic EDL formation on electrodes due to an applied AC field | Nonuniform EDL formation due to the polarization of metal or neutral post | Nonuniform permittivity and density due to nonuniform temperature as well as space charge | Densely packed micro-particles | Two immiscible fluid media with distinct permittivity |
Type of applied electric field | High voltage DC power | Low voltage and low-frequency AC | Intermediate range AC or DC voltage | Low voltage and high-frequency AC | Low voltage AC with phase lag | High AC or DC voltage |
Primary driving force | Coulombic forces | Coulombic forces | Coulombic forces | Coulombic and dielectric forces | Dielectric forces and fluid drag | Dielectric forces |
Major advantages | Very high pressure and high flow rate, and can be used for pumping | Low electric potential, and can be used for local flow control | Mid range electric potential, and does not create vortices | Low electric potential, and can be used for local flow control with vortices | Suitable for pumping particulate fluids with more controls | Continuous flow of liquids or droplets with high velocity |
Primary limitations | Very High voltage is needed, and bubble formation is very common | Negligible pressure build up and undesired flow reversal | Negligible to low-pressure build up | Negligible pressure build up and can only be used to highly conductive buffer | Cannot be used to pump fluids without densely packed particles | Dielectric coating on electrodes are needed, and cannot be used to pump one fluid |
Perspective on future research activities | Fundamental research and product development are expected to continue at the current or faster pace | Fundamental research activities are expected to accelerate in near future | Expected to drop due to lack of general interest in this area | Has the potential of significant increase in fundamental research in coming years | Not expected to grow in a significant manner | Failed to generate enough interest and unlikely to make a big splash in future too |
9.1 Electroosmotic pumping
Electroosmosis has been extensively used for pumping in the lab-on-a-chip microfluidic device. Surface coating, channel diameter, and electrode configurations are mainly used to control pumping in DC electroosmosis, while electrode structure and locations are the primary design parameters for AC electroosmosis. Analytical solutions for electroosmotic and mixed electroosmotic-pressure driven velocity distribution are available for DC electroosmotic pumping in rectangular or circular shaped microchannels. For a thin EDL limit, the electroosmotic flow can be modeled with the Helmholtz-Smoluchowski slip velocity at the channel wall. However, deviation from a typical plug-like flow profile can be observed due to non-uniform zeta potential at the channel surface or Joule heating within the channel.
Unlike its DC counterpart, a closed form analytical solution for AC electroosmosis is not possible due to nonlinearity in the electric field. In AC electroosmosis, electrodes are responsible for both creations of the electric field and EDL. Due to the close proximity of the neighboring electrodes, the electric potential applied in AC electroosmosis is much smaller than that of DC. Moreover, in AC electroosmosis, the flow field is highly nonuniform and localized close to the electrode regions. Although AC electroosmosis provides more design parameters, such as electrode geometry and electric field frequency for control, a global flow field cannot be obtained from AC electroosmotic pumping. Depending on the conductivity of the working medium, both DC and AC electroosmotic pumping mechanisms can generate heat as Joule heating [48, 199], which can affect the sample in bioseparation process.
9.2 ACET Pumping
Like AC electroosmosis, ACET pumping uses coplanar electrode design and AC electric field to create spatially varying heat source to facilitate temperature variation, which is responsible for the ACET flow. However, this mechanism is different from AC electroosmotic pumping in two ways. First, ACET uses much higher electric field frequencies than regular AC electroosmosis. Second, it takes advantage of variable fluid properties to generate spatially varying heat in the system. The complete modeling of ACET involves the solution of the complex electric field, energy, and fluid flow equations. However, the simplified mathematical model based on scaling law analysis can be applied to calculate electric field, which is used to find the dielectric and Coulomb forces. ACET pumping can be controlled by adding an external heating element in addition to modulating the number of energized electrodes and their orientations. ACET can also be supplemented with laser lighting or by including a DC bias to the regular AC electric field. Since the core working principles of ACET involved heat generation, this process might not be suitable for many bioanalyses, where the sample is temperature sensitive. One must carefully evaluate the benefits of using this technique in biological samples if other alternatives are available.
9.3 ICEO pumping
Dipolar double layer, due to the polarization of particles in an electrolyte, is responsible for ICEO. ICEO exhibits non-linear electrokinetics phenomena and becomes dominant physics at the smaller zeta potential. The ICEO can be modeled with Maxwell's equation, Nernst Plank equation, and fluid flow equation where Coulombic force is the driving mechanism for fluid flow. The pumping pressure can vary with applied electric potential as a quadratic relation depending on the frequency, electrolyte, and voltage. ICEO pumping mechanism has some unique advantages over other electroosmotic pumping, such as i) ICEO pumping can take place in both AC and DC electric field; ii) the direction of fluid flow and applied electric field directions are perpendicular to each other; and iii) operational frequency range in ICEO is much wider than the operational frequency range in ACEO.
9.4 DEP Pumping
Even though DEP is popularly used for the manipulation of particles, only traveling wave DEP and liquid DEP are used for microfluidic pumping. Travelling wave DEP can be obtained by applying AC electric potential on neighboring electrodes with a 90-degree phase difference. The phase differences on applied electric potential can create a moving electric field in a preferred direction, which can attract or repel particles suspended in fluid resulting in a movement of fluid. Traveling wave DEP can only be applied to a fluid with suspended particles, such as blood. In traveling wave DEP, the direction of the net flow depends on the relative magnitude of traveling wave period and the delay between imposed field and particle moments. If the delay between imposed field and induced particle moment is smaller than the half of the traveling wave period, the fluid flows against the propagating direction and vice-versa. The flow can be modulated through electrode design, applied electric potential magnitude and frequencies, properties of fluids and particles, etc.
On the other hand, the LDEP is used either to generate a continuous flow of liquid in a liquid-air interface or to move bubbles immersed in a liquid medium. The LDEP pumping mechanism is analogous to the capillary action since it influences hydrostatic equilibrium. This mechanism is different from general electroconvection based electrokinetic pumping. LDEP has been demonstrated to generate flow for both conductive and non-conductive liquid. In LDEP, the pumping velocity depends on the applied electric field, frequencies, the width of the electrode as well as the depth of the flow stream.
Acknowledgments
Research reported in this publication was supported in part by the National Science Foundation under Grant No. DMS-1317671 and in part by the National Institute of General Medical Sciences of the National Institutes of Health under Award Number R01GM122081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
References
- 1.Herr AE, Molho JI, Drouvalakis KA, Mikkelsen JC, Utz PJ, Santiago JG, Kenny TW. Analytical Chemistry. 2003;75:1180–1187. doi: 10.1021/ac026239a. [DOI] [PubMed] [Google Scholar]
- 2.Raisi F, Belgrader P, Borkholder DA, Herr AE, Kintz GJ, Pourhamadi F, Taylor MT, Northrup MA. Electrophoresis. 2001;22:2291–2295. doi: 10.1002/1522-2683(20017)22:11<2291::AID-ELPS2291>3.0.CO;2-A. [DOI] [PubMed] [Google Scholar]
- 3.Cui HC, Horiuchi K, Dutta P, Ivory CF. Analytical Chemistry. 2005;77:1303–1309. doi: 10.1021/ac048915+. [DOI] [PubMed] [Google Scholar]
- 4.Cui HC, Horiuchi K, Dutta P, Ivory CF. Analytical Chemistry. 2005;77:7878–7886. doi: 10.1021/ac050781s. [DOI] [PubMed] [Google Scholar]
- 5.Moore AW, Jacobson SC, Ramsey JM. Analytical Chemistry. 1995;67:4184–4189. [Google Scholar]
- 6.Jacobson SC, Hergenroder R, Koutny LB, Ramsey JM. Analytical Chemistry. 1994;66:1114–1118. [Google Scholar]
- 7.Harrison DJ, Fluri K, Seiler K, Fan ZH, Effenhauser CS, Manz A. Science. 1993;261:895–897. doi: 10.1126/science.261.5123.895. [DOI] [PubMed] [Google Scholar]
- 8.Mosher RA, Saville DA, Thormann W. The Dynamics of Electrophoresis. VCH, Weinheim; Germany: 1992. [Google Scholar]
- 9.Giddings JC. Analytical Chemistry. 1984;56:1258&. doi: 10.1021/ac00276a027. [DOI] [PubMed] [Google Scholar]
- 10.Gottschlich N, Jacobson SC, Culbertson CT, Ramsey JM. Analytical Chemistry. 2001;73:2669–2674. doi: 10.1021/ac001019n. [DOI] [PubMed] [Google Scholar]
- 11.Hunter RJ. Zeta Potential in Colloid Science. Academic Press; New York, NY: 1981. [Google Scholar]
- 12.Reuss FF. Memoires de la Societe Imperiale de Naturalistes de Moscou. 1809;2:327. [Google Scholar]
- 13.Wiedemann G. Pogg Ann. 1852;87:321. [Google Scholar]
- 14.Burgreen D, Nakache FR. Journal of Physical Chemistry. 1964;68:1084–1088. [Google Scholar]
- 15.Rice CL, Whitehead R. Journal of Physical Chemistry. 1965;69:4017–4023. [Google Scholar]
- 16.Kim MJ, Beskok A, Kihm KD. Experiments in Fluids. 2002;33:170–180. [Google Scholar]
- 17.Dutta P, Beskok A. Analytical Chemistry. 2001;73:5097–5102. doi: 10.1021/ac015546y. [DOI] [PubMed] [Google Scholar]
- 18.Jian YJ, Yang LG, Liu QS. Physics of Fluids. 2010;22 [Google Scholar]
- 19.Luo WJ. Journal of Colloid and Interface Science. 2004;278:497–507. doi: 10.1016/j.jcis.2004.06.017. [DOI] [PubMed] [Google Scholar]
- 20.Bhattacharyya S, Nayak AK. Colloids and Surfaces a-Physicochemical and Engineering Aspects. 2008;325:152–159. doi: 10.1016/j.colsurfa.2008.04.025. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Liu YP, Jian YJ, Liu QS, Li FQ. Journal of Molecular Liquids. 2015;211:784–791. [Google Scholar]
- 22.Peralta M, Arcos J, Mendez F, Bautista O. Fluid Dynamics Research. 2017;49 [Google Scholar]
- 23.Li FQ, Jian YJ, Xie ZY, Liu YB, Liu QS. Rsc Advances. 2017;7:782–790. [Google Scholar]
- 24.Suresh V, Homsy GM. Physics of Fluids. 2004;16:2349–2356. [Google Scholar]
- 25.Ramos A, Morgan H, Green NG, Castellanos A. Journal of Physics D-Applied Physics. 1998;31:2338–2353. [Google Scholar]
- 26.Lian M, Islam N, Wu J. Iet Nanobiotechnology. 2007;1:36–43. doi: 10.1049/iet-nbt:20060022. [DOI] [PubMed] [Google Scholar]
- 27.Jubery TZ, Srivastava SK, Dutta P. Electrophoresis. 2014;35:691–713. doi: 10.1002/elps.201300424. [DOI] [PubMed] [Google Scholar]
- 28.Fuhr G, Schnelle T, Wagner B. Journal of Micromechanics and Microengineering. 1994;4:217. [Google Scholar]
- 29.Hagedorn R, Fuhr G, Müller T, Gimsa J. Electrophoresis. 1992;13:49–54. doi: 10.1002/elps.1150130110. [DOI] [PubMed] [Google Scholar]
- 30.Bazant MZ, Squires TM. Physical Review Letters. 2004;92:066101. doi: 10.1103/PhysRevLett.92.066101. [DOI] [PubMed] [Google Scholar]
- 31.Probstein RF. Physicochemical Hydrodynamics: An Introduction. John Wiley & Sons; Hoboken, NJ: 2003. [Google Scholar]
- 32.Kilic MS, Bazant MZ, Ajdari A. Physical Review E. 2007;75 [Google Scholar]
- 33.Kilic MS, Bazant MZ, Ajdari A. Physical Review E. 2007;75 [Google Scholar]
- 34.Squires TM, Bazant MZ. Journal of Fluid Mechanics. 2004;509:217–252. [Google Scholar]
- 35.Shim J, Dutta P, Ivory CF. Electrophoresis. 2007;28:572–586. doi: 10.1002/elps.200600402. [DOI] [PubMed] [Google Scholar]
- 36.Castellanos A, Ramos A, Gonzalez A, Green NG, Morgan H. Journal of Physics D-Applied Physics. 2003;36:2584–2597. [Google Scholar]
- 37.Hossana MR, Dillonc R, Duttaa P. Journal of Computational Physics. 2014;270:640–659. [Google Scholar]
- 38.Liu Y, Liu WK, Belytschko T, Patankar N, To AC, Kopacz A, Chung JH. International Journal for Numerical Methods in Engineering. 2007;71:379–405. [Google Scholar]
- 39.Yoo K, Shim J, Dutta P. Biomicrofluidics. 2014;8 doi: 10.1063/1.4904805. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Karniadakis GE, Beskok A, Narayan A. Microflows and Nanoflows. Springer; New York, NY: 2005. [Google Scholar]
- 41.Dutta P, Beskok A. Analytical Chemistry. 2001;73:1979–1986. doi: 10.1021/ac001182i. [DOI] [PubMed] [Google Scholar]
- 42.Lu Y, Ren QL, Liu TT, Leung SL, Gau V, Liao JC, Chan CL, Wong PK. International Journal of Heat and Mass Transfer. 2016;98:341–349. doi: 10.1016/j.ijheatmasstransfer.2016.03.034. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Chu AKH. Physical Review E. 2005;72 [Google Scholar]
- 44.Cecchini M, Girardo S, Pisignano D, Cingolani R, Beltram F. Applied Physics Letters. 2008;92 [Google Scholar]
- 45.Ahmed D, Mao XL, Shi JJ, Juluri BK, Huang TJ. Lab on a Chip. 2009;9:2738–2741. doi: 10.1039/b903687c. [DOI] [PubMed] [Google Scholar]
- 46.Melcher, J., MIT, Cambridge, MA 1968.
- 47.Stratton JA. Electromagnetic theory. John Wiley & Sons; 2007. [Google Scholar]
- 48.Horiuchi K, Dutta P, Hossain A. Journal of Engineering Mathematics. 2006;54:159–180. [Google Scholar]
- 49.Xuan XC, Xu B, Sinton D, Li DQ. Lab on a Chip. 2004;4:230–236. doi: 10.1039/b315036d. [DOI] [PubMed] [Google Scholar]
- 50.Ross D, Johnson TJ, Locascio LE. Analytical chemistry. 2001;73:2509–2515. doi: 10.1021/ac001509f. [DOI] [PubMed] [Google Scholar]
- 51.Sinton D, Xuan X, Li D. Experiments in fluids. 2004;37:872–882. [Google Scholar]
- 52.Dutta P, Beskok A, Warburton TC. Numerical Heat Transfer Part a-Applications. 2002;41:131–148. [Google Scholar]
- 53.Herr AE, Molho JI, Santiago JG, Mungal MG, Kenny TW, Garguilo MG. Analytical Chemistry. 2000;72:1053–1057. doi: 10.1021/ac990489i. [DOI] [PubMed] [Google Scholar]
- 54.Gao M, Gui L. Advances in Microfluidics-New Applications in Biology, Energy, and Materials Sciences. InTech; 2016. [Google Scholar]
- 55.Gan We, Yang L, He Yz, Zeng Rh, Cervera ML, de la Guardia M. Talanta. 2000;51:667–675. doi: 10.1016/s0039-9140(99)00320-3. [DOI] [PubMed] [Google Scholar]
- 56.Zeng S, Chen CH, Mikkelsen JC, Santiago JG. Sensors and Actuators B: Chemical. 2001;79:107–114. [Google Scholar]
- 57.Yao S, Huber D, Mikkelsen JC, Santiago JG. Proceedings of the International Mechanical Engineering Congress and Exposition, New York. 2001 [Google Scholar]
- 58.Zeng S, Chen CH, Santiago JG, Chen JR, Zare RN, Tripp JA, Svec F, Fréchet JMJ. Sensors and Actuators B: Chemical. 2002;82:209–212. [Google Scholar]
- 59.Lazar IM, Karger BL. Anal Chem. 2002;74:6259–6268. doi: 10.1021/ac0203950. [DOI] [PubMed] [Google Scholar]
- 60.Chen CH, Santiago JG. Journal of Microelectromechanical Systems. 2002;11:672–683. [Google Scholar]
- 61.Laser DJ, Goodson KE, Santiago JG, Kenny TW. Proc 2002 Solid-State Sensor, Actuator, and Microsystems Workshop (Hilton Head Island, SC) 2002 [Google Scholar]
- 62.Takamura Y, Onoda H, Inokuchi H, Adachi S, Oki A, Horiike Y. ELECTROPHORESIS. 2003;24:185–192. doi: 10.1002/elps.200390012. [DOI] [PubMed] [Google Scholar]
- 63.Yao S, Hertzog DE, Zeng S, Mikkelsen JC, Santiago JG. Journal of Colloid and Interface Science. 2003;268:143–153. doi: 10.1016/s0021-9797(03)00730-6. [DOI] [PubMed] [Google Scholar]
- 64.Laser DJ, Myers AM, Yao S, Bell KF, Goodson KE, Santiago JG, Kenny TW. TRANSDUCERS, Solid-State Sensors, Actuators and Microsystems, 12th International Conference On, 2003. IEEE; 2003. pp. 151–154. [Google Scholar]
- 65.Tripp JA, Svec F, Fréchet JMJ, Zeng S, Mikkelsen JC, Santiago JG. Sensors and Actuators B: Chemical. 2004;99:66–73. [Google Scholar]
- 66.Razunguzwa TT, Timperman AT. Anal Chem. 2004;76:1336–1341. doi: 10.1021/ac034956e. [DOI] [PubMed] [Google Scholar]
- 67.Chen L, Guan Y, Ma J, Luo G, Liu K. Journal of Chromatography A. 2005;1064:19–24. doi: 10.1016/j.chroma.2004.11.085. [DOI] [PubMed] [Google Scholar]
- 68.Brask A, Kutter JP, Bruus H. Lab Chip. 2005;5:730–738. doi: 10.1039/b503626g. [DOI] [PubMed] [Google Scholar]
- 69.Chen Z, Wang P, Chang HC. Anal Bioanal Chem. 2005;382:817–824. doi: 10.1007/s00216-005-3130-7. [DOI] [PubMed] [Google Scholar]
- 70.Yao S, Myers AM, Posner JD, Rose KA, Santiago JG. Journal of Microelectromechanical Systems. 2006;15:717–728. [Google Scholar]
- 71.Wang P, Chen Z, Chang HC. Sensors and Actuators B: Chemical. 2006;113:500–509. [Google Scholar]
- 72.Nie FQ, Macka M, Barron L, Connolly D, Kent N, Paull B. Analyst. 2007;132:417–424. doi: 10.1039/b618386g. [DOI] [PubMed] [Google Scholar]
- 73.Nie FQ, Macka M, Paull B. Lab on a Chip. 2007;7:1597–1599. doi: 10.1039/b707773b. [DOI] [PubMed] [Google Scholar]
- 74.Miao JY, Xu ZL, Zhang XY, Wang N, Yang ZY, Sheng P. Advanced Materials. 2007;19:4234–+. [Google Scholar]
- 75.Vajandar SK, Xu D, Markov DA, Wikswo JP, Hofmeister W, Li D. Nanotechnology. 2007;18:275705. [Google Scholar]
- 76.Seibel K, Schöler L, Schäfer H, Böhm M. Journal of Micromechanics and Microengineering. 2007;18:025008. [Google Scholar]
- 77.Joo S, Chung TD, Kim HC. Sensors and Actuators B: Chemical. 2007;123:1161–1168. [Google Scholar]
- 78.Wallner JZ, Nagar N, Friedrich CR, Bergstrom PL. physica status solidi (a) 2007;204:1327–1331. [Google Scholar]
- 79.Edwards JM, Hamblin MN, Fuentes HV, Peeni BA, Lee ML, Woolley AT, Hawkins AR. Biomicrofluidics. 2007;1:014101. doi: 10.1063/1.2372215. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80.Chen YF, Li MC, Hu YH, Chang WJ, Wang CC. Microfluidics and Nanofluidics. 2008;5:235–244. [Google Scholar]
- 81.Borowsky JF, Giordano BC, Lu Q, Terray A, Collins GE. Anal Chem. 2008;80:8287–8292. doi: 10.1021/ac801497r. [DOI] [PubMed] [Google Scholar]
- 82.Berrouche Y, Avenas Y, Schaeffer C, Wang P, Chang HC. Journal of Fluids Engineering. 2008;130:081604. [Google Scholar]
- 83.Chen L, Li Q, Lee S, Choo J. IEEE Sensors Journal. 2008;8:488–494. [Google Scholar]
- 84.Ai Y, Yalcin SE, Gu D, Baysal O, Baumgart H, Qian S, Beskok A. Journal of colloid and interface science. 2010;350:465–470. doi: 10.1016/j.jcis.2010.07.024. [DOI] [PubMed] [Google Scholar]
- 85.Shin W, Lee JM, Nagarale RK, Shin SJ, Heller A. J Am Chem Soc. 2011;133:2374–2377. doi: 10.1021/ja110214f. [DOI] [PubMed] [Google Scholar]
- 86.Nagarale RK, Heller A, Shin W. Journal of The Electrochemical Society. 2011;159:P14–P17. [Google Scholar]
- 87.Gu C, Jia Z, Zhu Z, He C, Wang W, Morgan A, Lu JJ, Liu S. Anal Chem. 2012;84:9609–9614. doi: 10.1021/ac3025703. [DOI] [PubMed] [Google Scholar]
- 88.Cao Z, Yuan L, Liu YF, Yao S, Yobas L. Microfluidics and nanofluidics. 2012;13:279–288. [Google Scholar]
- 89.Luong D, Sprik R. ISRN Geophysics. 2013;2013 [Google Scholar]
- 90.Parashchenko MA, Filippov NS, Kirienko VV, Romanov SI. Optoelectronics, Instrumentation and Data Processing. 2014;50:315–322. [Google Scholar]
- 91.Li X, Liu S, Liang J, Miyamoto Ki, Yoshinobu T. physica status solidi (a) 2016;213:1500–1504. [Google Scholar]
- 92.Darabi J, Ohadi MM, DeVoe D. Journal of Microelectromechanical Systems. 2001;10:98–106. [Google Scholar]
- 93.Reichmuth DS, Kirby BJ. J Chromatogr A. 2003;1013:93–101. doi: 10.1016/s0021-9673(03)01468-7. [DOI] [PubMed] [Google Scholar]
- 94.Pu Q, Liu S. Analytica chimica acta. 2004;511:105–112. [Google Scholar]
- 95.Paul PH, Arnold DW, Rakestraw DJ. Micro Total Analysis Systems' 98. Springer; 1998. pp. 49–52. [Google Scholar]
- 96.Lazar IM, Trisiripisal P, Sarvaiya HA. Anal Chem. 2006;78:5513–5524. doi: 10.1021/ac060434y. [DOI] [PubMed] [Google Scholar]
- 97.Chen A, Lynch KB, Wang X, Lu JJ, Gu C, Liu S. Anal Chim Acta. 2014;844:90–98. doi: 10.1016/j.aca.2014.06.042. [DOI] [PubMed] [Google Scholar]
- 98.Buie CR, Posner JD, Fabian T, Cha SW, Kim D, Prinz FB, Eaton JK, Santiago JG. Journal of Power Sources. 2006;161:191–202. [Google Scholar]
- 99.Shuhuai Y, Myers AM, Posner JD, Rose KA, Santiago JG. Journal of Microelectromechanical Systems. 2006;15:717–728. [Google Scholar]
- 100.Gupta A, Denver H, Hirsa AH, Stenken JA, Borca-Tasciuc DA. Applied Physics Letters. 2007;91:094101. [Google Scholar]
- 101.Saumitra KV, Dongyan X, Dmitry AM, John PW, William H, Deyu L. Nanotechnology. 2007;18:275705. [Google Scholar]
- 102.Wang X, Cheng C, Wang S, Liu S. Microfluidics and Nanofluidics. 2009;6:145–162. doi: 10.1007/s10404-008-0399-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 103.Tanaka N, Kobayashi H, Ishizuka N, Minakuchi H, Nakanishi K, Hosoya K, Ikegami T. Journal of chromatography A. 2002;965:35–49. doi: 10.1016/s0021-9673(01)01582-5. [DOI] [PubMed] [Google Scholar]
- 104.Hayes JD, Malik A. Anal Chem. 2000;72:4090–4099. doi: 10.1021/ac000120p. [DOI] [PubMed] [Google Scholar]
- 105.Zhou L, Lu JJ, Gu C, Liu S. Anal Chem. 2014;86:12214–12219. doi: 10.1021/ac503223r. [DOI] [PubMed] [Google Scholar]
- 106.Gonzalez A, Ramos A, Green NG, Castellanos A, Morgan H. Physical Review E. 2000;61:4019–4028. doi: 10.1103/physreve.61.4019. [DOI] [PubMed] [Google Scholar]
- 107.Green NG, Ramos A, Gonzalez A, Morgan H, Castellanos A. Physical Review E. 2002;66 doi: 10.1103/PhysRevE.66.026305. [DOI] [PubMed] [Google Scholar]
- 108.Green NG, Ramos A, Gonzalez A, Morgan H, Castellanos A. Physical Review E. 2000;61:4011–4018. doi: 10.1103/physreve.61.4011. [DOI] [PubMed] [Google Scholar]
- 109.Yokokawa R, Manta Y, Namura M, Takizawa Y, Le NCH, Sugiyama S. Sensors and Actuators B: Chemical. 2010;143:769–775. [Google Scholar]
- 110.Pittman JL, Henry CS, Gilman SD. Analytical chemistry. 2003;75:361–370. doi: 10.1021/ac026132n. [DOI] [PubMed] [Google Scholar]
- 111.Urbanski JP, Levitan JA, Burch DN, Thorsen T, Bazant MZ. Journal of Colloid and Interface Science. 2007;309:332–341. doi: 10.1016/j.jcis.2007.01.095. [DOI] [PubMed] [Google Scholar]
- 112.Ajdari A. Physical Review E. 2000;61:R45. doi: 10.1103/physreve.61.r45. [DOI] [PubMed] [Google Scholar]
- 113.Mpholo M, Smith C, Brown A. Sensors and Actuators B: Chemical. 2003;92:262–268. [Google Scholar]
- 114.Brown A, Smith C, Rennie A. Physical review E. 2000;63:016305. doi: 10.1103/PhysRevE.63.016305. [DOI] [PubMed] [Google Scholar]
- 115.Ramos A, Gonzalez A, Castellanos A, Green NG, Morgan H. Physical review E. 2003;67:056302. doi: 10.1103/PhysRevE.67.056302. [DOI] [PubMed] [Google Scholar]
- 116.Olesen LH, Bruus H, Ajdari A. Physical Review E. 2006;73 doi: 10.1103/PhysRevE.73.056313. [DOI] [PubMed] [Google Scholar]
- 117.Garcia-Sanchez P, Ramos A, Green NG, Morgan H. Ieee Transactions on Dielectrics and Electrical Insulation. 2006;13:670–677. [Google Scholar]
- 118.Storey BD, Edwards LR, Kilic MS, Bazant MZ. Physical Review E. 2008;77 doi: 10.1103/PhysRevE.77.036317. [DOI] [PubMed] [Google Scholar]
- 119.Huang CC, Bazant MZ, Thorsen T. Lab on a Chip. 2010;10:80–85. doi: 10.1039/b915979g. [DOI] [PubMed] [Google Scholar]
- 120.Hossan MR, Dillon R, Roy AK, Dutta P. Journal of Colloid and Interface Science. 2013;394:619–629. doi: 10.1016/j.jcis.2012.12.039. [DOI] [PubMed] [Google Scholar]
- 121.Chiou PY, Ohta AT, Jamshidi A, Hsu HY, Wu MC. Journal of Microelectromechanical Systems. 2008;17:525–531. doi: 10.1109/JMEMS.2008.916335. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 122.Melvin EM, Moore BR, Gilchrist KH, Grego S, Velev OD. Biomicrofluidics. 2011;5 doi: 10.1063/1.3620419. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 123.Ivanoff CS, Swami NS, Hottel TL, Garcia-Godoy F. Electrophoresis. 2013;34:2945–2955. doi: 10.1002/elps.201300206. [DOI] [PubMed] [Google Scholar]
- 124.Zhou H, White LR, Tilton RD. Journal of Colloid and Interface Science. 2005;285:179–191. doi: 10.1016/j.jcis.2004.11.040. [DOI] [PubMed] [Google Scholar]
- 125.Rezanoor MW, Dutta P. Biomicrofluidics. 2016;10 doi: 10.1063/1.4943032. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 126.Chung CC, Glawdel T, Ren CL, Chang HC. Journal of Micromechanics and Microengineering. 2015;25 [Google Scholar]
- 127.Ishida A, Toki H, Motosuke M, Honami S. Journal of Thermal Science and Technology. 2012;7:475–486. [Google Scholar]
- 128.Hart R, Lec R, Noh H. Sensors and Actuators B-Chemical. 2010;147:366–375. [Google Scholar]
- 129.Hilber W, Weiss B, Saeed A, Holly R, Jakoby B. Sensors and Actuators a-Physical. 2009;156:115–120. [Google Scholar]
- 130.Hwang H, Park JK. Lab on a Chip. 2009;9:199–206. doi: 10.1039/b811740c. [DOI] [PubMed] [Google Scholar]
- 131.Song YJ, Chen PY, Chung MT, Nidetz R, Park Y, Liu ZH, McHugh W, Cornell TT, Fu JP, Kurabayashi K. Nano Letters. 2017;17:2374–2380. doi: 10.1021/acs.nanolett.6b05313. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 132.Han D, Park JK. Lab on a Chip. 2016;16:1189–1196. doi: 10.1039/c6lc00110f. [DOI] [PubMed] [Google Scholar]
- 133.Arefin MS, Porter TL. Journal of Applied Physics. 2012;111 [Google Scholar]
- 134.Das D, Yan Z, Menon NV, Kang Y, Chan V, Yang C. Rsc Advances. 2015;5:70197–70203. [Google Scholar]
- 135.Sigurdson M, Wang DZ, Meinhart CD. Lab on a Chip. 2005;5:1366–1373. doi: 10.1039/b508224b. [DOI] [PubMed] [Google Scholar]
- 136.Wu J, Lian M, Yang K. Applied Physics Letters. 2007;90 [Google Scholar]
- 137.Koklu A, Tansel O, Oksuzoglu H, Sabuncu AC. Iet Nanobiotechnology. 2016;10:54–61. doi: 10.1049/iet-nbt.2015.0014. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 138.Loire S, Kauffmann P, Mezic I, Meinhart CD. Journal of Physics D-Applied Physics. 2012;45 [Google Scholar]
- 139.Williams SJ. Electrophoresis. 2013;34:1400–1406. doi: 10.1002/elps.201200377. [DOI] [PubMed] [Google Scholar]
- 140.Yuan Q, Wu J. Biomedical Microdevices. 2013;15:125–133. doi: 10.1007/s10544-012-9694-z. [DOI] [PubMed] [Google Scholar]
- 141.Williams SJ, Green NG. Electrophoresis. 2015;36:1681–1689. doi: 10.1002/elps.201500112. [DOI] [PubMed] [Google Scholar]
- 142.Kwon JS, Wereley ST. Microfluidics and Nanofluidics. 2015;19:609–619. [Google Scholar]
- 143.Green NG, Ramos A, Gonzalez A, Castellanos A, Morgan H. Journal of Physics D-Applied Physics. 2000;33:L13–L17. [Google Scholar]
- 144.Gonzalez A, Ramos A, Morgan H, Green NG, Castellanos A. Journal of Fluid Mechanics. 2006;564:415–433. [Google Scholar]
- 145.Ng WY, Ramos A, Lam YC, Wijaya IPM, Rodriguez I. Lab on a Chip. 2011;11:4241–4247. doi: 10.1039/c1lc20495e. [DOI] [PubMed] [Google Scholar]
- 146.Jiang HY, Li SS, Hou ZX, Ren YK, Sun YJ. Acta Physica Sinica. 2011;60 [Google Scholar]
- 147.Vafaie RH, Ghavifekr HB, Van Lintel H, Brugger J, Renaud P. Electrophoresis. 2016;37:719–726. doi: 10.1002/elps.201500404. [DOI] [PubMed] [Google Scholar]
- 148.Selmi M, Gazzah MH, Belmabrouk H. Langmuir. 2016;32:13305–13312. doi: 10.1021/acs.langmuir.6b02637. [DOI] [PubMed] [Google Scholar]
- 149.Wu YP, Ren YK, Jiang HY. Electrophoresis. 2017;38:258–269. doi: 10.1002/elps.201600106. [DOI] [PubMed] [Google Scholar]
- 150.Salari A, Navi M, Dalton C. Biomicrofluidics. 2015;9 doi: 10.1063/1.4907673. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 151.Lang Q, Wu YS, Ren YK, Tao Y, Lei L, Jiang HY. Acs Applied Materials & Interfaces. 2015;7:26792–26801. doi: 10.1021/acsami.5b08863. [DOI] [PubMed] [Google Scholar]
- 152.Eckstein Y, Yossifon G, Seifert A, Miloh T. Journal of colloid and interface science. 2009;338:243–249. doi: 10.1016/j.jcis.2009.06.002. [DOI] [PubMed] [Google Scholar]
- 153.Zhao C, Yang C. Physical Review E. 2011;83:066304. doi: 10.1103/PhysRevE.83.066304. [DOI] [PubMed] [Google Scholar]
- 154.Pascall AJ, Squires TM. Journal of Fluid Mechanics. 2011;684:163–191. [Google Scholar]
- 155.Dukhin S. Advances in Colloid and Interface Science. 1993;44:1–134. doi: 10.1016/j.cis.2007.04.022. [DOI] [PubMed] [Google Scholar]
- 156.Mishchuk N, Takhistov P. Colloids and Surfaces A: Physicochemical and Engineering Aspects. 1995;95:119–131. [Google Scholar]
- 157.Lastochkin D, Zhou R, Wang P, Ben Y, Chang HC. Journal of Applied Physics. 2004;96:1730–1733. [Google Scholar]
- 158.Gangwal S, Cayre OJ, Bazant MZ, Velev OD. Physical review letters. 2008;100:058302. doi: 10.1103/PhysRevLett.100.058302. [DOI] [PubMed] [Google Scholar]
- 159.Gregersen MM, Okkels F, Bazant MZ, Bruus H. New Journal of Physics. 2009;11:075019. [Google Scholar]
- 160.Squires TM, Bazant MZ. Journal of Fluid Mechanics. 2006;560:65–101. [Google Scholar]
- 161.Sharp K, Yazdi S, Davison S. Microfluidics and Nanofluidics. 2011;10:1257–1267. [Google Scholar]
- 162.Sugioka H. Physical Review E. 2011;83:056321. doi: 10.1103/PhysRevE.83.056321. [DOI] [PubMed] [Google Scholar]
- 163.Paustian JS, Pascall AJ, Wilson NM, Squires TM. Lab on a Chip. 2014;14:3300–3312. doi: 10.1039/c4lc00141a. [DOI] [PubMed] [Google Scholar]
- 164.Feng H, Huang Y, Wong TN, Duan F. Soft Matter. 2017 doi: 10.1039/c7sm00787f. [DOI] [PubMed] [Google Scholar]
- 165.Bazant MZ, Urbanski JP, Levitan JA, Subramanian K, Kilic MS, Jones A, Thorsen T. Proceedings of 11th international conference on miniaturized systems for chemistry and life sciences (MicroTAS); 2007. pp. 2875–2878. [Google Scholar]
- 166.Nobari M, Movahed S, Nourian V, Kazemi S. Journal of Electrostatics. 2016;83:97–107. [Google Scholar]
- 167.Canpolat C, Zhang M, Rosen W, Qian S, Beskok A. Journal of Fluids Engineering. 2013;135:021103. [Google Scholar]
- 168.Pohl HA, Pohl H. Dielectrophoresis: the behavior of neutral matter in nonuniform electric fields. Cambridge university press; Cambridge: 1978. [Google Scholar]
- 169.Sato M, Yabe A, Taketani T. Proceedings of the 1991 ASME JSME thermal engineering joint conference; 1991. [Google Scholar]
- 170.Marczak M, Diesinger H. Journal of Applied Physics. 2009;105:124511. [Google Scholar]
- 171.Griffiths, D. J., AAPT 2005.
- 172.Wang X, Wang XB, Gascoyne PR. Journal of electrostatics. 1997;39:277–295. [Google Scholar]
- 173.Wang XB, Huang Y, Becker F, Gascoyne P. Journal of Physics D: Applied Physics. 1994;27:1571. [Google Scholar]
- 174.Huang Y, Holzel R, Pethig R, Wang XB. Physics in medicine and biology. 1992;37:1499. doi: 10.1088/0031-9155/37/7/003. [DOI] [PubMed] [Google Scholar]
- 175.Pethig R, Talary MS, Lee RS. IEEE engineering in medicine and biology magazine. 2003;22:43–50. doi: 10.1109/memb.2003.1266046. [DOI] [PubMed] [Google Scholar]
- 176.Tseng YL, Huang CW, Lei U, Lin CW, Jaw FS. Measurement. 2011;44:1980–1985. [Google Scholar]
- 177.Wang C, Wang X, Jiang Z. Biotechnology & Biotechnological Equipment. 2011;25:2405–2411. [Google Scholar]
- 178.Lei U, Huang C, Chen J, Yang C, Lo Y, Wo A, Chen C, Fung T. Lab on a Chip. 2009;9:1349–1356. doi: 10.1039/b822809d. [DOI] [PubMed] [Google Scholar]
- 179.Hughes MP, Pethig R, Wang XB. Journal of Physics D: Applied Physics. 1996;29:474. [Google Scholar]
- 180.Iverson BD, Cremaschi L, Garimella SV. Microfluidics and nanofluidics. 2009;6:221–230. [Google Scholar]
- 181.He G, Liu D. International Journal of Microscale and Nanoscale Thermal and Fluid Transport Phenomena. 2013;4:5. [Google Scholar]
- 182.Cimpeanu, R., Papageorgiou, D. T., 2014.
- 183.Wu Y, Ren Y, Tao Y, Jiang H. Microfluidics and Nanofluidics. 2017;21:38. [Google Scholar]
- 184.Dong L, Garimella S. Birck and NCN Publications. 2009:359. [Google Scholar]
- 185.Jones T. Journal of Electrostatics. 2001;51:290–299. [Google Scholar]
- 186.Fax R, Hurwitz M, Melcher J. Journal of Spacecraft and Rockets. 1969;6:961–967. [Google Scholar]
- 187.Jones TB. Langmuir. 2002;18:4437–4443. [Google Scholar]
- 188.Landau LD, Bell J, Kearsley M, Pitaevskii L, Lifshitz E, Sykes J. Electrodynamics of continuous media. elsevier; 2013. [Google Scholar]
- 189.Pellat H. C R Seances Acad Sci. 1894:675. [Google Scholar]
- 190.Tian H, Shao J, Ding Y, Li X, Liu H. Langmuir. 2013;29:4703–4714. doi: 10.1021/la400535p. [DOI] [PubMed] [Google Scholar]
- 191.Fan SK, Chen WJ, Lin TH, Wang TT, Lin YC. Lab on a Chip. 2009;9:1590–1595. doi: 10.1039/b900790c. [DOI] [PubMed] [Google Scholar]
- 192.Fan SK, Huang PW, Wang TT, Peng YH. Lab on a chip. 2008;8:1325–1331. doi: 10.1039/b803204a. [DOI] [PubMed] [Google Scholar]
- 193.Renaudot R, Daunay B, Kumemura M, Agache V, Jalabert L, Collard D, Fujita H. Sensors and Actuators B: Chemical. 2013;177:620–626. [Google Scholar]
- 194.Chen NC, Chen CH, Chen MK, Jang LS, Wang MH. Sensors and Actuators B: Chemical. 2014;190:570–577. [Google Scholar]
- 195.Velev OD, Prevo BG, Bhatt KH. Nature. 2003;426:515–516. doi: 10.1038/426515a. [DOI] [PubMed] [Google Scholar]
- 196.Jiao J, Almeida R, Kwon JW. Journal of Microelectromechanical Systems. 2016;25:884–889. [Google Scholar]
- 197.Prakash R, Papageorgiou DP, Papathanasiou AG, Kaler KV. Sensors and Actuators B: Chemical. 2013;182:351–361. [Google Scholar]
- 198.Kaler KV, Prakash R, Chugh D. Biomicrofluidics. 2010;4:022805. doi: 10.1063/1.3411003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 199.Horiuchi K, Dutta P. International Journal of Heat and Mass Transfer. 2004;47:3085–3095. [Google Scholar]