Skip to main content
Oncotarget logoLink to Oncotarget
. 2018 Jan 12;9(17):13948–13958. doi: 10.18632/oncotarget.24189

MiR-486 as an effective biomarker in cancer diagnosis and prognosis: a systematic review and meta-analysis

Min Jiang 1,2, Xuelian Li 1,2, Xiaowei Quan 1,2, Xianglin Yang 1,2, Chang Zheng 1,2, Xia Hao 1,2, Ruoyi Qu 1,2, Baosen Zhou 1,2,3
PMCID: PMC5862628  PMID: 29568407

Abstract

Purpose

MiR-486 was found to be associated with cancer’s diagnosis and prognosis. This meta-analysis aimed to investigate the potential effect of miR-486 on cancer detection and prognosis.

Materials and Methods

We searched PubMed, Cochrane library, Embase, Chinese National Knowledge Infrastructure (CNKI) and Wanfang databases to find all correlated articles. The STATA 11.0 was applied to estimate the pooled effects, heterogeneity and publication bias.

Results

The pooled sensitivity (SEN), specificity (SPE) and Area under the curve (AUC) were 82% (95% CI: 78–85%), 88% (95% CI: 83–92%) and 0.91 (95% CI: 0.88–0.93). Subgroup analysis indicated miR-486 from circulating samples exhibited higher diagnostic accuracy with the AUC was 0.90 (95% CI: 0.87–0.92) than miR-486 from other specimen with the AUC of 0.78 (95% CI: 0.75–0.82) and miR-486 obtained a better diagnostic value in the Asian population with the AUC of 0.94 (95% CI: 0.91–0.95) than the Caucasian and Caucasian/African population with the AUC of 0.80 (95% CI: 0.76–0.83) and 0.89 (95% CI: 0.86–0.91) respectively. MiR-486 obtained high value for the diagnosis of non-small cell lung cancer with SEN, SPE and AUC were 0.82 (95% CI: 0.0.77–0.87), 0.90 (95% CI: 0.84–0.94) as well as 0.92 (95% CI: 0.89–0.94) respectively. For the 7 prognostic tests, the pooled hazard ratio (HR) was 0.48 (95% CI: –0.13–1.08) for low versus high miR-486 expression.

Conclusions

This meta-analysis indicated that miR-486 can be used as ideal biomarkers in the cancer’s diagnosis. However, Low miR-486 expression did not increase the risk of poor outcome.

Keywords: miR-486, cancer, meta-analysis, diagnostic, prognosis

INTRODUCTION

MicroRNA is a group of 19–22 nucleotide, small, single-stranded and conserved non-coding RNA that acts as a regulator of gene expression at both the post-transcriptional and the translational levels through acting on the 3’-untranslated region (UTR) of messenger RNA (mRNA) [1]. MicroRNAs involve in various biological processes associated with the tumorigenesis such as the cellular proliferation, differentiation, metabolism as well as apoptosis [2, 3]. It is available to isolate the microRNAs from the clinical specimens including the plasma, serum, sputum and tissue. Meanwhile, it has a high stability. Due to these advantages, the microRNAs are increasingly becoming an ideal tool for the detection of human cancer.

Aberrant expression of miR-486 (miR-486-5p) has been reported to be associated with different types of human cancer such as hepatocellular carcinoma (HCC) [4, 5], lung cancer [6], breast cancer [7], esophageal squamous cell carcinoma (ESCC) [8] and pancreatic cancer (PC) [9, 10]. It can act as both the tumor suppressor and oncogene to participant in the development and progression of tumors. The down-regulation of miR-486 can promote the progression of lung cancer [6], HCC [4, 5], breast cancer [7] and osteosarcoma [11], while it is usually up-regulated in PC [9, 10], chronic myeloid leukemia [12] and gliomas [13]. Recently, a series of articles have identified that miR-486 might be applied as a biomarker for cancer detection and prognosis. However, as a result of the small sample sizes, different microRNA profiling and the differences of the specimen and ethnicity, many articles showed conflicting conclusions and no meta-analysis was conducted to explore the association between miR-486 and diagnosis as well as the prognosis of human cancer. Therefore, this meta-analysis was performed to assess the performance of miR-486 in the detection and prognosis for human cancer.

RESULTS

Literature search and the studies’ characteristics

As described in Figure 1A, based on the primary literature research, 402 eligible articles were included, of which 368 articles were removed as duplicate and unrelated articles. And then 7 reviews and 3 articles about miR-486-3p were also excluded, leaving 24 articles with full texts. After carefully reading, another 3 articles were then removed: 1 article without complete data and 2 articles with the same population with other articles. Ultimately, 21 articles [1433] with 29 studies were published from 2010 to 2017. 15 articles [1428] with 22 studies were about the value of miR-486 for cancer detection while the remaining 6 articles [2933] with 7 studies were about the cancer prognosis.

Figure 1.

Figure 1

Flow chart of this meta-analysis of miR-486 in cancer detection (A) and the quality of these included articles according to the QUADAS-2 guidelines: proportion of articles with risk of bias (left) and proportion of articles with regarding applicability (right) (B).

Diagnostic meta-analysis

Studies’ characteristics and quality assessment

A total of 15 articles with 22 studies involving in 1315 cases and 1013 controls were analyzed. The main characteristics of the 22 studies were shown in Table 1. Types of cancer included lung cancer, non-small cell lung cancer (NSCLC), gastric cancer (GC), renal cell cancer (RCC) and pancreatic cancer (PC).The quantitative real-time polymerase chain reaction (qRT-PCR) was used in these studies to test the expression level of miR-486, and the most common reference miRNAs used as the endogenous controls for normalization were RNU6B (U6), miR-39 and miR-16. The quality of the included studies turned out to be generally good and was summarized in Figure 1B.

Table 1. The main features of 22 included studies in diagnostic meta-analysis.
Study ID ethnicity specimen cas
e
con
trol
Cancer-type Control-type stage miRNA Reference miRNA method SEN (%) SPE (%)
N age N age
Sromek M 2017 Caucasian Plasma 61 63 50 57 NSCLC HC I-IV miR-16, miR-205,miR-486 miR-24-3p qRT-PCR 80.00 95.00
Wang X 2016 Asian plasma 59 56 59 58 NSCLC BD I-III miR-486,miR-210,CYFRA21-1 miR-16 qRT-PCR 84.70 72.80
Butz H 2016 Caucasian Urinary Exosome 28 59 18 NA RCC HC NA miR-126-3p, miR-486-5p miR-16-5p,miR-106a-5p qRT-PCR 72.40 60.00
Butz H 2016 Caucasian Urinary Exosome 81 NA 33 NA RCC HC NA miR-126-3p, miR-486-5p miR-16-5p,miR-106a-5p qRT-PCR 81.30 62.50
Cao Z 2016 Asian plasma 29 NA 16 NA PC BD I-IV miR-486-5p,miR-126-3p,miR-106b-3p,miR-938,miR-26b-3p, miR-1285 U6 qRT-PCR 83.90 80.80
Cao Z 2016 Asian plasma 156 NA 57 NA PC BD I-IV miR-486-5p,miR-126-3p,miR-106b-3p U6 qRT-PCR 82.70 84.40
Xu JW 2016 Asian plasma 156 NA 65 NA PC HC I-IV miR-486-5p U6 qRT-PCR 75.00 87.70
Wang LL 2016 Asian serum 100 59 50 58 GC HC I-IV miR-486 U6 qRT-PCR 76.00 98.00
Yang Y 2016 Asian plasma 35 NA 30 NA lung cancer HC I-IV miR-486 cel-miR-39 qRT-PCR 90.00 68.60
Tai M 2016 Asian blood 110 65 52 66 LAD HC I-IV 20miRs1 miR-159a,U6 qRT-PCR 89.10 100.00
Tai M 2016 Asian blood 143 66 49 66 LAD HC I-IV 20miRs1 miR-159a,U6 qRT-PCR 94.40 98.00
Li WS 2016 Asian plasma 11 59 11 55 NSCLC HC I-III MiR-486 miR-39 ,RNU44 qRT-PCR 90.90 81.80
Jiang X 2015 Asian plasma 35 NA 30 NA lung cancer BD/HC I-IV miR-486 cel-miR-39 qRT-PCR 88.50 83.30
Zhu C 2014 Asian plasma 48 57 102 54 GC HC I miR-16,miR-25,miR-92a,miR-451, miR-486-5p cel-miR-39 qRT-PCR 72.90 89.20
Zhu C 2014 Asian plasma 40 54 40 54 GC HC I miR-16,miR-25,miR-92a,miR-451,miR-486-5p cel-miR-39 qRT-PCR 97.50 87.50
Mozzoni P 2013 Caucasian plasma 54 69 46 64 NSCLC BD I-III miR-21,miR-486 miR-16 qRT-PCR 87.00 86.50
Shen J 2011 Caucasian, African plasma 58 68 29 66 NSCLC HC I-IV miR-21,miR-126,miR-210,miR-486-5p miR-16 qRT-PCR 86.20 96.60
Bianchi F 2011 Caucasian serum 25 NA 39 NA LAD HC I-IV 34miRs2 6miRs3 qRT-PCR 69.00 84.00
Bianchi F 2011 Caucasian serum 34 NA 30 NA NSCLC HC I-IV 34miRs2 6miRs3 qRT-PCR 71.00 90.00
Shen Jun 2011 Caucasian, African plasma 32 66 33 65 NSCLC BD I-IV miR-21,miR-210,miR-486-5p miR-16 qRT-PCR 75.00 84.90
Shen J 2011 Caucasian, African plasma 76 68 80 65 NSCLC BD I-IV miR-21,miR-210,miR-486-5p miR-16 qRT-PCR 76.30 85.00
Yu L 2010 Caucasian, African sputum 36 68 36 67 LAD HC I miR-486,miR-21,miR-200b,miR-375 U6 qRT-PCR 80.60 91.70
Yu L 2010 Caucasian, African sputum 64 67 58 65 NSCLC HC I-IV miR-486,miR-21,miR-200b,miR-375 U6 qRT-PCR 70.30 80.00

1:miR-451,miR-1290,miR-636,miR-30c,miR-22-3p,miR-19b,miR-486-5p,miR-20b,miR-93,miR-34b,miR-185,miR-126-5p,miR-93-3p,miR-1274a,miR-142-5p,miR-628-5p,miR-486-3p,miR-425,miR-645,miR-24. 2: let-7a, let-7b, let-7d, miR-103, miR-126, miR-133b, miR-139, miR-140, miR-142, miR-142, miR-148a, miR-148b, miR-17, miR-191, miR-22, miR-223, miR-26a, miR-26b, miR-28, miR-29a, miR-30b, miR-30c, miR-32, miR-328, miR-331, miR-342, miR-374, miR-376a, miR-432, miR-484, miR-486, miR-566, miR-92a and miR-98. 3: miR-197, miR-19b, miR-24, miR-146, miR-15b, miR-19a. Abbreviation: N, number of samples; HC, healthy control; BD, benign disease; SEN, sensitivity; SPE, specificity. NSCLC, non-small cell lung cancer; RCC, renal cell cancer; PC, pancreatic cancer; GC, gastric cancer; LAD, lung adenocarcinoma.

Pooled diagnostic performance

The significant heterogeneity was observed since I2 for SEN and SPE were 62.12% (95% CI: 44.65–79.58%) and 69.43% (95% CI: 56.08–82.78%) respectively. Therefore, we used a random-effect model for this analysis. Results showed that overall pooled SEN and SPE for these 22 studies were 82% (95% CI: 78-85%) and 88% (95% CI: 83–92%) respectively to distinguish patients with cancer from the controls (Figure 2). The positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 6.9 (95% CI: 4.8–9.7) and 0.21 (95% CI: 0.17–0.26) respectively, and the diagnostic odds ratio (DOR) was 33 (95% CI: 20–55). The summary receiver operating characteristic (SROC) curve was performed and the AUC was 0.91 (95% CI: 0.88–0.93) (Figure 3A).

Figure 2. Forest plots of sensitivity and specificity for the cancer diagnosis of miR-486.

Figure 2

Both the sensitivity and specificity of each study were showed by square with its 95% Confidence interval showed by the error bars.

Figure 3.

Figure 3

SROC curve of the miR-486 as diagnostic tools for cancer (A) and the Deek’s test for assessing the publication bias for miR-486 in the detection of cancer (B).

Publication bias and sensitivity analysis

In this meta-analysis, Deek’s funnel plot asymmetry test was applied to test the probability of publication bias. The funnel plot was symmetry (Figure 3B) and P value equaled 0.39, which demonstrated the publication bias didn’t exist in these studies. Sensitivity analysis was also conducted but failed to find the sources of heterogeneity.

Subgroup analysis and meta-regression analysis

A multivariate-meta-regression was performed to detect the potential causes of the heterogeneity in both SEN and SPE. The following factors were included: miRs (miR-486 alone or miR-486 with other miRNAs); specimen (circulating or not circulating); ethnicity (Asian, Caucasian or Caucasian/African); control-type (benign disease or healthy controls); stage (early stage or overall stage); cancer-type (lung cancer, gastric cancer, pancreatic cancer and renal cell carcinoma and sample-size (>=100 or < 100). The results demonstrated that specimen (P < 0.05) might explain the heterogeneity in SPE shown in Figure 4. Meanwhile, the subgroup analyses were also conducted and the results were presented in Table 2. Subgroup analysis by specimen showed that studies with circulating samples exhibited higher diagnostic accuracy with SEN: 81% (95% CI: 78–84%), SPE: 86% (95% CI: 83-89%) and AUC: 0.90 (95% CI: 0.87-0.92) (Figure 5A) than studies with not circulating samples with the SEN: 76% (95% CI: 70–82%), SPE: 76% (95% CI: 62–86%) and AUC: 0.78 (95% CI: 0.75–0.82) (Figure 5B) respectively. In the subgroup of the ethnicity, the miR-486 obtained a better diagnostic value in the Asian population with the SEN: 86% (95% CI: 80–90%), SPE: 90% (95% CI: 84–94%) and AUC: 0.94 (95% CI: 0.91–0.95) (Figure 6A) when Compared with the Caucasian population with the SEN: 79% (95% CI: 74–83%), SPE: 83% (95% CI: 71–91%) and AUC: 0.80 (95% CI: 0.76–0.83) (Figure 6B) and the Caucasian/African population with SEN: 78% (95% CI: 71–84%), SPE: 87% (95% CI: 80–92%) and AUC: 0.89 (95% CI: 0.86–0.91) (Figure 6C) respectively. With respect to the other types of subgroup analysis, there were no significant differences in the diagnostic accuracy of miR-486 and since there were only 3 studies for early stage and 2 studies that we did not obtain the information about the stage, we only conducted the subgroup analysis for the overall stage of human cancer. However, for the subgroup analysis of NSCLC, it obtained a pretty high diagnostic value with the sensitivity, specificity were 82% (95% CI: 77–87%), 90% (95% CI: 84–94%) respectively as well as the AUC was 0.92 (95% CI: 0.89–0.94) (Figure 6D).

Figure 4. Forest plots for the Meta-regression analysis: sensitivity and specificity.

Figure 4

The factors included ethnicity, specimen, control, stage, cancer, miRs and sample size.

Table 2. The subgroup analysis for the selected studies.

Subgroups No.of studies SEN [95% CI] SPE [95% CI] PLR [95% CI] NLR [95% CI]) DOR [95% CI]) AUC [95% CI]
MiRNA profiling
 single 4 0.78 [0.72–0.83] 0.90 [0.80–0.95] 7.6 [3.9–14.6] 0.24 [0.19–0.32] 31 [15–64] 0.84 [0.81–0.87]
 multiple 18 0.83 [0.79–0.86] 0.90 [0.86–0.93] 8.0 [5.7–11.4] 0.19 [0.15–0.24] 42 [25–70] 0.93 [0.90–0.95]
Specimen
 circulating 18 0.81 [0.78–0.84] 0.86 [0.83–0.89] 6.0 [4.7–7.6] 0.22 [0.18–0.26] 28 [20–37] 0.90 [0.87–0.92]
 not circulating 4 0.76 [0.70–0.82] 0.76 [0.62–0.86] 3.2 [1.9–5.4] 0.31 [0.23–0.41] 10 [5–21] 0.78 [0.75–0.82]
Ethnicity
 Asian 11 0.86 [0.80–0.90] 0.90 [0.84–0.94] 8.9 [5.1–15.4] 0.16 [0.11–0.23] 55 [25–120] 0.94 [0.91–0.95]
 Caucasian 6 0.79 [0.74–0.83] 0.83 [0.71–0.91] 4.7 [2.6–8.3] 0.25 [0.20–0.33] 18 [9–39] 0.80 [0.76–0.83]
Caucasian/African 5 0.78 [0.71–0.84] 0.87 [0.80–0.92] 6.2 [3.7–10.4] 0.25 [0.18–0.35] 24 [11–53] 0.89 [0.86–0.91]
Control–type
 HC 15 0.81 [0.76–0.86] 0.91 [0.84–0.95] 8.7 [5.0–15.1] 0.21 [0.15–0.28] 42 [19–92] 0.91 [0.88–0.93]
 BD 6 0.82 [0.78–0.85] 0.83 [0.77–0.87] 4.7 [3.6–6.1] 0.22 [0.18–0.27] 21 [14–32] 0.87 [0.84–0.90]
Cancer type
 NSCLC 13 0.82 [0.77–0.87] 0.90 [0.84–0.94] 8.4 [5.0–14.1] 0.20 [0.15–0.26] 43 [20–92] 0.92 [0.89–0.94]
Sample size
 > = 100 12 0.82 [0.77–0.86] 0.90 [0.82–0.94] 8.1 [4.4–14.7] 0.20 [0.15–0.27] 40 [18–90] 0.90 [0.87–0.92]
 < 100 10 0.82 [0.75–0.87] 0.86 [0.81–0.90] 5.8 [4.1–8.2] 0.21 [0.15–0.30] 28 [15–51] 0.91 [0.88–0.93]
Stage
 overall stage 17 0.82 [0.78–0.85] 0.89 [0.85–0.93] 7.8 [5.2–11.6] 0.20 [0.16–0.26] 38 [21–68] 0.91 [0.88–0.93]
 Overall studies 22 0.82 [0.78–0.85] 0.88 [0.83–0.92] 6.9 [4.8–9.7] 0.21 [0.17–0.26] 33 [20–55] 0.91 [0.88–0.93]

No: the number of the studies; HC, healthy control; BD, benign pulmonary disease; SEN, sensitivity; SPE, specificity; PLR, positive likelihood ratio; NLR, negative likelihood ratio; DOR, Diagnostic Odds Ratio; AUC, area under the curve.

Figure 5.

Figure 5

SROC curve of the miR-486 from circulating samples (A) and the other specimen (B).

Figure 6.

Figure 6

SROC curve of the miR-486 in detection of Asian population (A), Caucasian population (B) and the Caucasian/ African population (C) as well as the SROC curve of miR-486 in the diagnosis of non-small cell lung cancer (D).

Prognostic meta-analysis

Studies’ characteristics and quality assessment

A total of 761 participants with cancer from 6 articles on 7 studies were included. The main characteristics of the 7 studies were shown in Table 3 Most studies investigated miR-486 by qRT-PCR. The overall survival (OS), progression-free survival (PFS) and relapse free survival (RFS) were used to evaluate the outcome of the cohorts. Types of the cancer included NSCLC, ESCC, GC and HCC. The results of the studies’ quality assessment were also included in Table 3.

Table 3. The main features of 7 included studies in prognostic meta-analysis.
Study ID sex (male/ female age ethnicity specimen cancer-type stage miRNA reference miRNA method outcome follow-up (month) HR ll ul NOS
Guo J 2016 25/9 57 Asian serum NSCLC III-IV miR-486 cel-miR-39 qRT-PCR PFS > 8.5 2.04 1.00 4.13 8
Ren CL 2016 137/36 NA Asian tissue ESCC I-IV miR-486-5p Scramble-miR miRNA-LNA OS 93.6 4.32 2.62 7.14 7
Ren CL 2016 73/21 NA Asian tissue GC I-IV miR-486-5p Scramble-miR miRNA-LNA OS 87.6 2.46 1.35 4.50 7
Li WS 2015 7/4 59 Asian plasma NSCLC I-III miR-486 cel-miR-39 ,RNU44 qRT-PCR RFS 24 0.11 0.01 1.06 7
Petriella D 2015 21/9 65 Caucasian serum NSCLC III-IV miR-486-5p U6 qRT-PCR PFS > 15 5.59 1.32 23.26 7
Wang LM 2015 94/22 54 Asian serum HCC NA MiR-486-5p U6 qRT-PCR RFS 24 1.27 1.12 1.43 7
Hu ZB 2010 222/81 60 Asian serum NSCLC I-III miR-486 NA qRT-PCR OS 61.8 0.50 0.34 0.74 7

Abbreviation: HR, hazard ratio; ll, lower limit; ul, upper Limit; NOS, Newcastle-Ottawa Scale; NSCLC, non-small cell lung cancer; ESCC, esophageal squamous cell carcinoma; GC, gastric cancer; HCC, hepatocellular carcinoma; OS, overall survival; PFS, progression-free survival; RFS, relapse free survival.

Association between miR-486 and outcomes

A random-effects model was used since the heterogeneity among studies existed (I2 = 89.9, P = 0.000). The pooled HR (hazard ratio) was 0.48 (95% CI: –0.13–1.08) for low versus high miR-486 expression as shown in Figure 7A. Low miR-486 expression did not increase the risk of poor outcome compared with the high miR-486 expression. And the studies were so few that we did not conduct subgroup analysis for the prognostic meta-analysis.

Figure 7.

Figure 7

Forest plots of sensitivity and specificity for miR-486 in cancer prognosis (A) and the Begg’s funnel plot for the sensitivity analysis (B).

Publication bias and sensitivity analysis

Publication bias was checked by Begg’s funnel plot and Egger’s test under the random-effects model (Figure 7B). Although the Begg’s funnel plot seemed asymmetric, the P value of the Egger’s regression intercept was 0.676, indicating that there was no obvious publication bias among these studies. The sensitivity analysis was also conducted but failed to find the sources of heterogeneity.

DISCUSSION

Cancer biomarkers are critical for cancer detection and predicting the outcome as well as choosing the suitable treatment methods. As involving in various biological processes in cancer, miRNA was considered to play a crucial role in cancer diagnosis and prognosis surveillance.

MiR-486 has been reported to be involved in different types of cancer. Research in the mechanism of miR-486 found that the down-regulation of miR-486 could target genes such as ARHGAP5 to inhibit cell migration and invasion in vitro and metastasis in vivo in lung cancer [6] and it could inhibit cancer cell proliferation, migration and invasive in vitro and suppress HCC growth in vivo by targeting PIK3R1 [4]. Furthermore, miR-486 might inhibit cell growth of papillary thyroid carcinoma by targeting fibrillin-1 [34] and estrogen receptor-mediated miR-486 could regulate expression of OLFM4 in ovarian cancer [35].

This present meta-analysis aimed to estimate the pooled effect of miR-486 expression on diagnosis and prognosis of human cancer. The diagnostic accuracy of miR-486 was pretty high. The adjusted pooled SEN, SPE and AUC were 82% (95% CI: 78–85%), 88% (95% CI: 83–92%) and 0.91 (95% CI: 0.88–0.93) respectively. With respect to the subgroup analysis, the circulating miR-486 obtained a higher diagnostic value than miR-486 from other specimen. In addition, the accuracy of miR-486 to detect cancer for Asian population was higher than Caucasian or Caucasian/ African population. The pooled AUC of 0.92 (95% CI: 0.89-0.94) indicated that the performance of miR-486 to detect NSCLC was feasible. As for the value of miR-486 on prognosis of cancer, the pooled HR was 0.48 (95% CI: -0.13–1.08) for low versus high miR-486 expression showed that low miR-486 expression did not increase the risk of poor outcome.

To our best knowledge, this meta-analysis was the first one to explore the effect of miR-486 on cancer diagnosis and prognosis. Although we perform this meta-analysis strictly according to the PRISMA guidelines, there were still some limitations that could not be neglected in this meta-analysis. First, the types of cancer included and the studies of each cancer as well as the samples of cases were so few that we could not conduct the subgroup analysis for the prognostic meta-analysis and these limitations might partly contribute to the negative result. Second, the heterogeneity among these studies could not be neglected and some articles might be missed or not be published online that did not be included in this meta-analysis. Third, most studies were from China in the prognostic meta-analysis and the results might just represent the prognostic value of miR-486 on Chinese cancer. Therefore, Studies on the large samples are still demanded to verify our results.

MATERIALS AND METHODS

Search strategy

We based our meta-analysis on the Preferred Reporting Items for meta-analyses (PRISMA). We searched PubMed, Cochrane library, Embase, Chinese National Knowledge Infrastructure (CNKI) and Wanfang databases to find all associated articles in order to investigate the potential utility of miR-486 as a diagnostic and prognostic surveillance tool for human cancer. The combination of the Medical Subject Headings (MeSH) and the keywords: (miR-486 or hsa-miR-486 or microRNA-486 or miR486) and (cancer or tumor or carcinoma or neoplasm) was used (updated to September 13, 2017). We also searched reference lists of the reviews aiming at obtaining other acceptable articles.

Study selection

There was a series of criteria for records inclusion as well as exclusion. For inclusion, records needed to meet the following criteria: 1) Patients of the cases were with cancer; 2) The controls were healthy controls (HC) or with benign diseases (BD); 3) Assess the diagnostic or prognostic value of miR-486 (miR-486-5p); 4) The TP, FP, FN, TN for the diagnosis and HR (hazard ratio) and its 95% CI for the prognosis can be extracted or calculated from the articles. For the exclusion, the criteria as follows: 1) Records that were review, meta-analysis and duplicate publications as well as the records unrelated; 2) Records without complete data or with the same population; 3) Records were about the miR-486-3p.

Data collection and quality assessment

The data was collected independently by two authors as follows: the first author, year of publication, subject’s demographic characteristics (ethnicity, mean or median age, sample size, testing method of miR-486 and the types of the controls and cancer); types of the specimen; follow-up time and the outcomes; miRNA profiling and the data used for this meta-analysis (SEN, SPE, TP, FP, FN, TN, HR and its 95% CI). All HRs were reformatted as low miR-486 expression versus high miR-486 expression. We assessed the quality of these articles with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) guidelines for the diagnostic records and followed the guidelines of the Newcastle-Ottawa Scale (NOS) for the prognostic publications [36, 37].

Statistical analysis

We performed the statistical analysis using the STATA 11.0 (STATA-Corp, College Station, TX, version 11.0) software and RevMan 5.3 (version 1.4) software. A bivariate random effect-regression model was applied to assess the pooled SEN [TP/ (FN+TP)], SPE [TN/ (FP+TN)], the positive likelihood ratio (PLR) [(SEN/ (1-SEN)], the negative likelihood ratio (NLR) [(1-SPE)/SPE)], the diagnostic odds ratio (DOR) [PLR/ NLR] and the pooled HR with its 95% Confidence Interval (95% CI) respectively. We also constructed the SROC curve and calculated the AUC value. Simultaneously, we assessed the heterogeneity among the selected studies through the Q test and the I2 value [38]. The P value for the Q test less than 0.05 or the I2 ≥ 50% demonstrated that there was heterogeneity among the included studies. For the diagnostic meta-analyses, meta-regression analysis and subgroup analysis (grouped by miRNA profiling: single miR-486 and multiple miRNAs including miR-486 and other miRNAs; specimen: circulating and not circulating; ethnicity: Asian, Caucasian and Caucasian/African; control-type: benign disease and healthy controls; stage: early stage and not only early stage; cancer-type: lung cancer, gastric cancer, pancreatic cancer and renal cell carcinoma and sample size: >= 100 and < -100) were used to identify the potential sources of the heterogeneity and the Deek ’s funnel plot asymmetry test was also applied to explore the publication bias, with the P value less than 0.01 considered significant [39]. As for the prognostic meta-analyses, Begg’s and Egger’s tests were selected to evaluate the included studies for the possibility of publication bias. Finally, the sensitivity analysis was conducted to explore the possible sources of heterogeneity for both the diagnosis and the prognosis meta-analysis.

CONCLUSIONS

This was the first meta-analysis to confirm the potential value of miR-486 on cancer diagnosis and prognosis. The expression of miR-486 might be an effective biomarker for detection of human cancer.

Acknowledgments

Thanks for the efforts of all the authors.

Abbreviations

miR-486

has-miR-486/ has-miR-486-5p

miRNA

microRNA

mRNA

messenger RNA

3’-UTR

3’-untranslated region

NSCLC

non-small cell lung cancer

HCC

hepatocellular carcinoma

ESCC

esophageal squamous cell carcinoma

PC

pancreatic cancer

GC

gastric cancer

RCC

renal cell cancer

PRISMA

preferred Reporting Items for meta-analysis

HC

Healthy Control

BD

benign disease

SEN

sensitivity

SPE

specificity

SROC

summary receiver operating characteristic

AUC

the area under the SROC curve

CNKI

Chinese national knowledge infrastructure

PLR

positive likelihood ratio

NLR

negative likelihood ratio

DOR

diagnostic odds ratio

TP

true positive

FP

false positive

FN

false negative

TN

true negative

qRT-PCR

quantitative real-time polymerase chain reaction

HR

hazard ratio

OS

overall survival

PFS

progression-free survival

RFS

relapse free survival

QUADAS-2

the Quality Assessment of Diagnostic Accuracy Studies-2

NOS

the Newcastle-Ottawa Scale

Footnotes

CONFLICTS OF INTEREST

The authors declare no conflicts of interest.

REFERENCES


Articles from Oncotarget are provided here courtesy of Impact Journals, LLC