In regard to “Tran A, Zhang J, Woods K, Yu V, Nguyen D, Gustafson G, Rosen L, Sheng K. Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases. Radiation oncology. 2017 Jan 11; 12(1):10”

Biplab Sarkar 1,
PMCID: PMC5896086  PMID: 29650027

Abstract

This article describe the three dimensional geometrical incompetency of the term “4π radiotherapy”; frequently used in radiation oncology to establish the superiority (or rather complexity) of particular kind of external beam delivery technique. It was claimed by several researchers, to obtain 4πc solid angle at target centre created by the tele-therapy delivery machine in three dimensional Euclidian space. However with the present design of linear accelerator (or any other tele-therapy machine) it is not possible to achieve more than 2πc with the allowed boundary condition of 0 ≤ Gnatry position≤πc and πc2≤Couch Position≤+πc2 .

This article describes why it is not possible to achieve a 4πc solid angle at any point in three dimensional Euclidian spaces. This article also recommends not to use the terminology “4π radiotherapy” for describing any external beam technique or its complexity as this term is geometrically wrong.

Keywords: 4π radiotherapy, π, Sold angle, Solid geometry, 3D Euclidian space, Gantry , Couch, Linear accelerator, Radian

Text

I would like to make a comment on the “4π radiotherapy”; mentioned by Tarn et al. regarding the 4π radiotherapy for prostate cases. The concept of 4π radiotherapy was originally floated by Dong et al. in 2013; and subsequently used by several authors; calming to have delivered a radiotherapy technique which look into a tumour from 4π solid angle [18].

The geometrical constriction of a teletherapy machine/linear accelerator mechanically represent a Cantilever, where head anchored at only one end with a vertical support from which it is protruding. A teletherapy machine having two additional degree of freedoms; a full arc gantry rotation of (0-2πc) and a half arc couch rotation (0-πc).

Geometry of three dimensional Euclidian space, solid geometry, defines the angle obtained by a surface in terms of solid angle presented as following.

=dsr2

where ds is the surface area and r is the radius vector can obtained a solid angle of 4πc at its centre as described below.

Solid angle at the centre of a sphere

Ω=Arear2=1r2θ=0πφ=02πrSinθdφ.rdθ

where, r, θ and φ are radius vector polar and azimuthal angle.

=4πr2r2=4πc=12.56ccis steradian.

Under the geometrical boundary condition of the linear accelerator rotational degree of freedom (gantry: 00–3600-00 and couch 900–00-2700; however 900–1800–2700 is inaccessible to couch) azimuthal angle integration reduces to 0-πc. Therefore maximum accessible solid angle for a linear accelerator machine is

=1r2θ=0πφ=0πrSinθdφ.rdθ=2πc; solid angle obtained by a hemisphere.

This type of hemispherical therapy delivery is only possible for two ends of the human that is either brain or foot. Rest of the length (head neck-thorax-abdomen-pelvis) of the human body is not accessible even for a 2πc radiotherapy. Therefore claimed to have “4π radiotherapy” for prostate does not hold geometrically.

I would like to mention that, as an example, the solid angle created by a full arc (0-2πc) gantry rotation with a 40 × 40 cm2 field opening and couch angle at zero degree is

ΩFullARC=Arear2=1100cm22π100cm×40cm=2.51c,

which is (1/5)th of the 4πc. Solid angle further reduces with the multileaf collimator shaped or blocked fields.

To perform a “4π radiotherapy” a patient need to be point and radiotherapy machines should be able to move to any point on the surface of a spare; under the present design of any teletherapy machines like linear accelerator, tele-cobalt, tomotherapy (Accuray Inc., Madison, WI) or Cyber knife (Accuray Inc., Madison, WI) cannot perform a “4π radiotherapy”. Probably only Brachytherapy can be near to a “4π radiotherapy” approximating (highly) the source as a point source.

A generalised geometrical misconception of “4π radiotherapy” was floated in 2013 by Dong et al. and propagating up to date (Victoria et al.) [18].

The technique described by the listed authors in this article could have been identified (or nomenclated) by something else but definitely not by “4π radiotherapy”. “4π Radiotherapy” is a geometrically non-viable and scientifically wrong concept; tagged with a fancy name to establish its superiority over generalized non-coplanar technique. Therefore the misconception about “4π radiotherapy” need to be corrected should not be used in future.

Acknowledgements

None

Funding

Not applicable

Availability of data and materials

No data generated, only mathematical formulation. Mathematical information used here is available in any standard mathematics text book.

Abbreviations

c

Steradian or radian unit of solid angle

r, θ and φ

Radius vector polar and azimuthal angle in spherical polar coordinate

π

Pi is a number - approximately 3.142

Ω

Solid angle: defined as ratio between area and squire of the radius vector

Authors’ contributions

The author read and approved the final manuscript.

Ethics approval and consent to participate

Not required, no patient data/ information Involved.

Consent for publication

Not required, no patient data/ information Involved.

Competing interests

The author declares that he/she has no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Footnotes

An author's reply to this comment is available online at https://doi.org/10.1186/s13014-018-1010-5.

References

  • 1.Tran A, Zhang J, Woods K, Yu V, Nguyen D, Gustafson G, Rosen L, Sheng K. Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases. Radiat Oncol. 2017;12(1):10. doi: 10.1186/s13014-016-0761-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Dong P, Lee P, Ruan D, Long T, Romeijn E, Yang Y, Low D, Kupelian P, Sheng K. 4π non-coplanar liver SBRT: a novel delivery technique. international journal of radiation oncology* biology*. Physics. 2013;85(5):1360–1366. doi: 10.1016/j.ijrobp.2012.09.028. [DOI] [PubMed] [Google Scholar]
  • 3.Dong P, Lee P, Ruan D, Long T, Romeijn E, Low DA, Kupelian P, Abraham J, Yang Y, Sheng K. 4π noncoplanar stereotactic body radiation therapy for centrally located or larger lung tumors. International journal of radiation oncology* biology*. Physics. 2013;86(3):407–413. doi: 10.1016/j.ijrobp.2013.02.002. [DOI] [PubMed] [Google Scholar]
  • 4.Rwigema JC, Nguyen D, Heron DE, Chen AM, Lee P, Wang PC, Vargo JA, Low DA, Huq MS, Tenn S, Steinberg ML. 4π noncoplanar stereotactic body radiation therapy for head-and-neck cancer: potential to improve tumor control and late toxicity. International journal of radiation oncology* biology*. Physics. 2015;91(2):401–409. doi: 10.1016/j.ijrobp.2014.09.043. [DOI] [PubMed] [Google Scholar]
  • 5.Yu VY, Tran A, Nguyen D, Cao M, Ruan D, Low DA, Sheng K. The development and verification of a highly accurate collision prediction model for automated noncoplanar plan delivery. Med Phys. 2015;42(11):6457–6467. doi: 10.1118/1.4932631. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Nguyen D, Rwigema JC, Victoria YY, Kaprealian T, Kupelian P, Selch M, Lee P, Low DA, Sheng K. Feasibility of extreme dose escalation for glioblastoma multiforme using 4π radiotherapy. Radiat Oncol. 2014;9(1):239. doi: 10.1186/s13014-014-0239-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Nguyen D, Dong P, Long T, Ruan D, Low DA, Romeijn E, Sheng K. Integral dose investigation of non-coplanar treatment beam geometries in radiotherapy. Medical physics. 2014;41(1). [DOI] [PubMed]
  • 8.Victoria YY, Landers A, Woods K, Nguyen D, Cao M, Du D, Chin RK, Sheng K, Kaprealian TB. A Prospective 4π Radiotherapy Clinical Study in Recurrent High Grade Glioma Patients. Int J Radiat Oncol Biol Phys. 2018. [DOI] [PubMed]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

No data generated, only mathematical formulation. Mathematical information used here is available in any standard mathematics text book.