Abstract
Purpose
In total knee arthroplasty (TKA), the posterior tibial slope is not always reconstructed correctly, and the knee ligaments may become too tight in flexion. To release a tight flexion gap, surgeons can increase the posterior tibial slope using two surgical resection techniques: the anterior tibial cortex (ACR) or the centre of tibial plateau (CPR) referencing. It is not known how this choice affects the knee laxity and function during activities of daily living. The aim of this study was to investigate the effect of tibial slope on knee laxity, kinematics and forces during a squatting activity using computer simulation techniques. We hypothesised that the effects depend on the referencing technique utilised.
Methods
A validated musculoskeletal model of TKA was used. Knee laxity tests were simulated in flexion and extension. Then, a squat motion was simulated to calculate: movement of the tibiofemoral joint (TFJ) contact points and patello-femoral joint (PFJ) contact force. All analyses were repeated with more anterior (−3°), neutral (0°), and more posterior tibial slope (+3°, +6°, +9°), and with two referencing techniques (ACR, CPR).
Results
Knee laxities increased dramatically with more posterior slope with the ACR technique (up to 400%), both in flexion and in extension. The CPR technique, instead, had much smaller effects (up to 42% variations). During squatting, more slope with the ACR technique resulted in larger movements of the TFJ contact point. The PFJ contact force decreased considerably with more slope with the CPR technique (12% body weight reduction every 3° more posterior slope), thanks to the preservation of the patellar height and quadriceps–femur load sharing.
Conclusion
ACR technique alters considerably the knee laxity, both in flexion and extensions, and surgeons should be cautious about its use. More slope with CPR technique induces more favourable TFJ kinematics and loading of the knee extensor apparatus and does not substantially alter knee laxity. Preferably, the tibial slope resection should be pre-planned thoroughly and performed using CPR technique as accurately as possible. Surgeons can directly translate the results of this study into the clinical practice.
Electronic supplementary material
The online version of this article (doi:10.1007/s00167-017-4561-3) contains supplementary material, which is available to authorized users.
Keywords: Posterior, Tibial, Slope, Musculoskeletal, Computer, Model, Force, Dependent, Kinematics, Simulation, Knee, Arthroplasty, Biomechanics, CR, TKA
Introduction
A successful total knee arthroplasty (TKA) should reduce knee pain and restore function to normal levels. For this purpose, the reconstructed tibiofemoral joint (TFJ) should be stable throughout the whole range of knee flexion. The posterior tibial slope was shown to affect substantially the knee laxity, hence the stability, in a cadaveric study [16].
In conventional TKA, the posterior tibial slope cannot always be reconstructed correctly, due to uncertainty of the surgical instruments and a large inter-patient variability (95% CI [1.0°, 15.8°]) [8]. Often, an arbitrary angle of posterior slope is aimed for (3° or 7° are common choices) according to the recommendation of the prosthesis manufacturer. In cruciate-retaining (CR)-TKA, particularly, an insufficient posterior tibial slope may result in flexion gap tightness and reduced post-operative flexion [15, 16, 22]. To increase the flexion gap, surgeons tend to increase the posterior tibial slope intra-operatively, using the anterior tibial cortex as a reference (anterior tibial cortex referencing, ACR) [22]. This technique lowers the TFJ line and affects the tension of the soft tissues. Based on clinical observations of the authors, a little increase in posterior tibial slope could increase the flexion gap considerably and cause laxity in flexion with subsequent aberrant kinematics. These factors may put the implant at increased risk of wear [24] and lead to (mid-)flexion instability. A different surgical approach is to plan the desired tibial slope pre-operatively, based on the knee system, and to reference the tibial bone cut from the midpoint of the tibial plateau (centre of tibial plateau referencing, CPR). In the latter case, the choice of the posterior tibial slope does not substantially alter the TFJ line at the centre of the cut surface of the proximal tibia [20]. Only a limited number of studies were found in the literature on the effect of posterior tibial slope in TKA, which show contradictory results [16, 19, 25, 26]. Also little attention was paid to the surgical referencing technique used, and the effect of tibial slope on the forces in the TFJ, PFJ and knee ligaments during activities of daily living (ADLs).
The purpose of this study was, therefore, to investigate the effect of alterations of the tibial slope on TFJ laxity and kinematics, quadriceps, patello-femoral and ligament forces during a demanding activity, and to elucidate possible differences arising from the surgical referencing technique. The hypothesis was that the tibial slope influences the knee laxity, kinematics and loads both in flexion and extension, and that the effect depends on the referencing technique. This study presents novel findings on the effects of tibial slope and surgical techniques on the biomechanics of the reconstructed knee, which may be translated directly into the clinical practice.
Materials and methods
An existing patient-specific musculoskeletal model of CR-TKA was used for this study (Fig. 1) [17]. The model was previously validated against experimental measurements of TFJ contact forces during normal and right turn gait in a patient with a telemetric knee prosthesis, and sagittal plane kinematics during unloaded leg-swing trial under fluoroscopic examination [11]. Details of the model are provided in a separate Appendix. The tibial insert (Congruent NK-II CR, Zimmer Biomet, Warsaw, IN, USA) of the knee prosthesis had a conforming shape, with upwardly sloping lipped bearings at both the anterior and posterior rims of the insert. The post-operative posterior tibial slope was quantified as the angle of built-in slope of the tibial insert plus the angle of the post-operative tibial resection, measured relative to the tibial mechanical axis. The tibial mechanical axis was defined as the axis connecting the tibial intercondylar eminence, proximally, to the centre of the inferior tibial articular surface (tibial plafond), distally. The post-operative tibial slope was equal to 0° (neutral slope) and represented the baseline case for successive comparisons.
To assess the effect of surgical referencing technique, two series of analyses were designed. In the first series, the tibial slope was altered by rotating the tibial component on the sagittal plane around a pivot point located at the anterior aspect of the proximal tibia (ACR technique, Fig. 2a). With such technique, a more posterior tibial slope would shift distally all the points of the tibial plateau, and a more anterior slope, would shift them proximally. In the second series, the pivot point was defined as the midpoint between the centres of the medial and lateral tibial plateaus (CPR technique, Fig. 2b). In this situation, a more posterior tibial slope would shift distally all the points located posteriorly to the pivot point, and proximally all the points located anteriorly, and vice versa for a more anterior slope. In addition to the neutral slope case (0°), four more cases were analysed, three with more posterior slope (+3°, +6°, +9°) and one with more anterior slope (–3°), with both ACR and CPR technique, leading to five slope cases in each technique.
Anterior–posterior (AP) and varus–valgus (VV) laxity tests were simulated. An unloaded case was first analysed, in which the knee joint sought its own equilibrium position throughout a 0°–90° knee flexion range. The anterior tibial translation and varus angle were calculated according to Grood and Suntay’s joint coordinate system definition [13]. Subsequently, anterior and posterior forces of 70 N in magnitude [4] were applied to the proximal tibia, and the correspondent AP translations recorded. Similarly, varus and valgus loads of 15 N m in magnitude [14] were applied to the tibia by means of 50 N-forces, applied 30 cm below the TFJ line and directed medially and laterally, respectively. The correspondent varus and valgus rotations were recorded. Measurements of laxity were obtained at 0°, 30°, 60°, 90° of knee flexion. The anterior and posterior laxities were calculated as the tibial translation during the anterior and posterior laxity tests, respectively, minus the tibial translation in the unloaded case. The varus and valgus laxities were calculated as the knee angle during the varus and valgus laxity tests, respectively, minus the knee angle in the unloaded case.
To investigate the knee kinematics and forces under loading, a two-legged squatting motor task (PS_2legsquat1) from the fifth Grand Challenge Competition To Predict In Vivo Knee Loads dataset [11] was analysed, which started from a standing position, followed by a descending phase and an ascending phase. The range of knee flexion was approximately 0°–90°. Throughout the squatting task, the following outcomes were calculated: the displacement of the TFJ contact point, calculated as the centre of pressure of the medial and lateral TFJ contact forces, the forces in the MCL, LCL and PCL, the quadriceps muscle forces, the force exchanged between the quadriceps tendon and the femur condyles through wrapping (quadriceps–femur force), and the PFJ contact force.
Results
Laxity with ACR technique
The anterior laxity increased with more posterior slope with the ACR technique, in all knee flexion angles (Fig. 3, blue series). The posterior laxity increased with more posterior slope, in extension, whereas it did not show a clear trend for the other flexion angles. Both valgus and varus laxities increased with more posterior slope in all knee flexion angles. Both anterior, posterior, valgus and varus laxities decreased with more anterior slope (−3°), in all knee flexion angles.
Laxity with CPR technique
Knee laxity was less affected by changes in tibial slope with CPR technique (Fig. 3, yellow series), than with ACR technique. The anterior laxity decreased with more posterior tibial slope with the CPR technique, in all knee flexion angles. Valgus and varus laxities slightly decreased with more posterior slope, in extension. In all other knee flexion angles, only marginal changes (<0.4°) in valgus and varus laxity occurred with more posterior slope. A more anterior slope caused changes in laxity, which were less than 20% of the neutral case values, with the exception of the varus laxity in extension, which increased by 0.4° (+39%).
Kinematics and loads during squatting
The distance travelled by the TFJ contact point increased on both medial and lateral side with more posterior tibial slope with ACR technique, and it was not altered substantially with the CPR technique (Fig. 4).
The peak PCL force during squatting decreased with more posterior slope with both referencing techniques (Fig. 5, left). Both medial and lateral collateral ligament peak forces decreased with more posterior slope (Fig. 5, centre and right). However, with the CPR technique neither ligament became slack, and the force reduction was more moderate, when compared to the ACR technique.
The peak quadriceps force during squatting decreased by 5.2% body weight (BW), on average, for every 3° more posterior slope with the ACR technique (Fig. 6, left). Similarly, the quadriceps–femur force decreased by 11% BW (Fig. 6, centre), and the peak PFJ contact force decreased by 5% BW, on average (Fig. 6, right). With the CPR technique, the peak quadriceps force during squatting decreased by 3.5% BW, on average, for every 3° more posterior slope; the peak quadriceps–femur force slightly increased, and the peak PFJ contact force decreased by 12% BW, on average.
Discussion
The main finding of this study was that the knee laxity increased substantially, both in flexion and, unexpectedly, also in extension with more posterior tibial slope in case the ACR technique was simulated. In contrast, varying the tibial slope with the CPR technique had little effects on knee laxity. The tension of the TFJ ligaments during simulated squat decreased with more posterior tibial slope for both referencing techniques, indicating a progressive loosening of the TFJ gap with more posterior slope, although the changes were more distinct with the ACR technique. Also a previous study found decreased PCL strain with more posterior tibial slope [22]. No aberrant TFJ contact point movements were observed during simulated squat, even with large degrees of posterior tibial slope, when the CPR technique was simulated. This is in agreement with a previous fluoroscopic study on knee kinematics during stair ascent, getting up from and sitting down on a chair and single-leg climbing up a step [6], in which the original slope was restored and the post-operative slope ranged from −2° to 10°. Therefore, the concern for increased risk of wear, due to extreme roll-back with more posterior tibial slope [24], does not appear much justified, based on results of this study, as long as the TFJ gap is successfully balanced in both flexion and extension. In contrast, more slope with the ACR technique resulted in larger excursions of the TFJ contact point in extension on both medial and lateral side, owing to a loosened TFJ gap, which in turn may lead to increased wear of the polyethylene insert. A more posterior location of the TFJ contact point can, in principle, increase the quadriceps moment arm and reduce the quadriceps force [7, 10]. Previous studies found more posterior TFJ contact point (in vivo) [12] and reduced quadriceps forces (ex vivo) [21] with more posterior tibial slope. In the present study, the peak quadriceps forces were reduced during squatting with more posterior tibial slope with both referencing techniques. The patella shifted superiorly relative to the femur condyles with more posterior tibial slope with the ACR technique, due to lowering of the TFJ line. This reduced the force exchanged between quadriceps tendon and femoral condyles by wrapping (Fig. 7, centre). With the CPR technique, the patellar height remained unchanged, and the quadriceps–femur load sharing was preserved. Also the PFJ contact force was more effectively reduced with more posterior tibial slope with the CPR technique (−12% BW every 3°) relative to the ACR technique (−5% BW every 3°). Although the difference was relatively small, decreased PFJ contact forces may contribute to reduce anterior knee pain and implant wear [3] after following CR-TKA.
In the present study, a validated patient-specific musculoskeletal model was used to simulate laxity tests and a squatting activity, under different tibial slope conditions. Furthermore, a highly controlled and parameterised study design was adopted, in which the degree of tibial slope and the referencing technique were the sole variables. A major strength of this approach lies in the possibility to isolate the effect of tibial slope from the effect of all the other variables that may possibly affect the outcomes of TKA, and which in previous literature may have acted as confounders. Distinct biomechanical pathways could be identified from altering the tibial slope with different referencing techniques. Also previous studies found important effects of tibial slope on knee laxity, especially those which used a referencing technique similar to the ACR of this study [16, 22]. Conversely, more posterior tibial slope obtained with the CPR technique did not cause such big effects on TFJ laxity, in the present study. Also Whiteside and Amador found no major differences in the mean knee laxity parameters after increasing the posterior tibial slope [25], using posteriorly sloped tibial inserts. Their method did not alter the level of the TFJ line in correspondence of the centre of the tibial plateaus and is analogous to the CPR technique simulated in this study.
Posterior tibial slope has been proposed as a viable alternative to PCL release to address flexion gap tightness in CR-TKA [16, 26]. In the present study, it was shown that a more posterior slope with CPR technique loosens the TFJ in flexion. This finding is supported by the study of Okazaki et al. [20], which shows an increase in the flexion gap of 2 mm for every 5° increase in the posterior tibial slope, using the CPR technique. In any case, the increase in tibial slope should never be at the expenses of the tibial insertions of PCL [18]. In CR-TKA, the PCL has a major role in governing the stability of the TFJ [23]. Therefore, caution should be used when performing the proximal tibial resection with an increased slope, and the appropriate surgical tools should be used to prevent damage of the PCL tibial insertion.
Interestingly a more posterior tibial slope, obtained with the ACR technique—which is meant to address a flexion tightness problem—produces, in fact, remarkable effects also in extension. This can be explained by noting that the ACR technique shifts all points of the tibial plateau distally, which, in turn, loosens the TFJ throughout the whole knee flexion–extension range. In clinical practice, if the extension gap has been already successfully balanced, any further increase in the posterior tibial slope (using the ACR technique) will alter the level of the TFJ line, which reduces the tension of the soft tissues (MCL, LCL and PCL), and increases the laxity of the knee both in flexion and in extension. Surgeons should, therefore, pay much attention when altering the tibial slope using the ACR technique, as it may have serious consequences for the overall stability of the knee.
The results of this study suggest that a thorough pre-planning of the desired tibial slope should be made, which considers both the type of implant available and the surgical technique utilised, and that the execution of the tibial resections should be as accurate as possible. One factor in the decision is the knee system used. Some systems have tibial inserts available with a built-in slope of 3°–4°. With these systems, the surgeon should be careful to aim for too much slope with the primary cut, and rather aim for 0°–3°. With other systems, that do not have slope in the insert, the surgeon could aim for more slope, e.g. 3°–6° in the tibial cut, but referenced from the centre of the tibial plateau. Another factor is the native tibial slope of the patient. When a patient has a large native tibial slope, e.g. 10°, the surgeon can anticipate a tight knee in flexion when using a limited sloped cut. A pre-operatively planned slope, referenced from the centre of the tibial plateau, may help creating a correct balance and prevent the disadvantages of the anterior referenced slope for such a patient. The native tibial slope of the present case study was about 7°, as measured on the available pre-operative CT images. Interestingly, the simulated cases with +6° and +9° of slope with CPR technique—being the nearest to the native slope—both provided the best biomechanical results. The native tibial slope may be an important parameter to take into account in the pre-operative planning, which is also very easy to measure on pre-operative radiographs.
Obviously, this study had several limitations. The musculoskeletal computer model represented a CR-TKA, and the results should not be generalised to other implant designs such as the PS-TKA. Although the principles behind knee surgery are similar, the mechanisms by which stability is achieved in flexion are radically different, as the CR-TKA relies on the preservation of the PCL, whereas the PS-TKA relies on a post-cam mechanism embedded in the prosthesis.
Nearly complete slackening of the PCL was observed in the preset study, already with +3° slope. This effect may be due to the strain parameters assigned to the bundles of the PCL. It should be noted that the sagittal plane knee kinematics were validated against experimental measurements of a free leg-swing fluoroscopy trial, which showed some signs of PCL laxity. It is plausible that the parameters of the PCL of the present model reflected those of a relatively lax PCL, and that knees with a perfectly functional PCL after CR-TKA will likely exhibit less slackening of the PCL in flexion.
The effects of tibial slope on the knee biomechanics were analysed during a single squatting motor task, by simulating multiple cases of tibial slope. In principle, it would be possible to analyse also other motor tasks, e.g. corresponding to several ADLs, but this would require additional computer analyses, which would add to the computation time. A squatting motion was chosen for the simulations, since it included both a wide range of flexion–extension and a significant muscular endeavour around the knee joint. Care should also be taken not to extrapolate the results of the present study to deep flexion, as this range was not investigated.
When analysing squatting, it was assumed that the overall body kinematics and loading conditions would hold among different configurations of the tibial slope. Some neuro-motor adaptations may occur as a result of alterations of the prosthesis alignment, but the study of those fell out of the scope of the present study. Nevertheless, the computational analysis technique employed allowed to predict changes in knee kinematics and forces, resulting from changes in the tibial slope, as intended.
Conclusion
Changes in posterior tibial slope have considerable effects on knee laxity, kinematics and forces. More posterior tibial slope with the ACR technique increases the knee laxity in flexion, but also, unexpectedly, in extension. More posterior slope with CPR technique leaves the knee laxity almost uninfluenced, is beneficial for the knee extensor apparatus and relieves the pressure on the PFJ. The tibial resection should be pre-planned and executed as accurately as possible using CPR technique.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Acknowledgments
Authors’ contributions
MAM implemented the analyses through musculoskeletal modelling, analysed the data and drafted the manuscript. MS helped to draft the manuscript and carry out the analyses. DWJ, BFJMK, SAWvdG helped in the analysis and interpretation of the data and critically revised the manuscript for intellectual content. PJCH participated in the design and coordination of the study and helped to draft the manuscript. ABW and NJJV conceived of the study and contributed to the interpretation of the data. All authors read and approved the final manuscript.
Compliance with ethical standards
Conflict of interest
The authors declare that they have no conflict of interest.
Funding
This project was supported by the European Research Council under the European Union’s Seventh Framework Programme (FP/2007-2013), ERC Grant Agreement no. 323091 awarded to N.V.
Ethical approval
Approval is not required for this type of study.
Informed consent
Formal consent is not required for this type of study.
Footnotes
Electronic supplementary material
The online version of this article (doi:10.1007/s00167-017-4561-3) contains supplementary material, which is available to authorized users.
Contributor Information
Marco A. Marra, Phone: +31 (0)24 361 73 79, Email: Marco.Marra@radboudumc.nl
Marta Strzelczak, Email: strzelczak.marta@gmail.com.
Petra J. C. Heesterbeek, Email: P.heesterbeek@maartenskliniek.nl
Sebastiaan A. W. van de Groes, Email: Sebastiaan.vandeGroes@radboudumc.nl
Dennis W. Janssen, Email: Dennis.Janssen@radboudumc.nl
Bart F. J. M. Koopman, Email: h.f.j.m.koopman@utwente.nl
Ate B. Wymenga, Email: A.wymenga@maartenskliniek.nl
Nico J. J. Verdonschot, Email: Nico.Verdonschot@radboudumc.nl
References
- 1.Andersen MS, Damsgaard M, Rasmussen J. Kinematic analysis of over-determinate biomechanical systems. Comput Methods Biomech Biomed Eng. 2009;12:371–384. doi: 10.1080/10255840802459412. [DOI] [PubMed] [Google Scholar]
- 2.Bennett WF, Doherty N, Hallisey MJ, Fulkerson JP. Insertion orientation of terminal vastus lateralis obliquus and vastus medialis obliquus muscle fibers in human knees. Clin Anat. 1993;6:129–134. doi: 10.1002/ca.980060302. [DOI] [Google Scholar]
- 3.Browne C, Hermida JC, Bergula A, Colwell CW, D’Lima DD. Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm. Knee. 2005;12:81–88. doi: 10.1016/j.knee.2004.05.006. [DOI] [PubMed] [Google Scholar]
- 4.Bull AMJ, Kessler O, Alam M, Amis AA. Changes in knee kinematics reflect the articular geometry after arthroplasty. Clin Orthop Relat Res. 2008;466:2491–2499. doi: 10.1007/s11999-008-0440-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Carbone V, Fluit R, Pellikaan P, van der Krogt MM, Janssen D, Damsgaard M, Vigneron L, Feilkas T, Koopman HFJM, Verdonschot N. TLEM 2.0—a comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity. J Biomech. 2015;48:734–741. doi: 10.1016/j.jbiomech.2014.12.034. [DOI] [PubMed] [Google Scholar]
- 6.Catani F, Fantozzi S, Ensini A, Leardini A, Moschella D, Giannini S. Influence of tibial component posterior slope on in vivo knee kinematics in fixed-bearing total knee arthroplasty. J Orthop Res. 2006;24:581–587. doi: 10.1002/jor.20121. [DOI] [PubMed] [Google Scholar]
- 7.Churchill DL, Incavo SJ, Johnson CC, Beynnon BD. The influence of femoral rollback on patellofemoral contact loads in total knee arthroplasty. J Arthroplasty. 2001;16:909–918. doi: 10.1054/arth.2001.24445. [DOI] [PubMed] [Google Scholar]
- 8.de Boer JJ, Blankevoort L, Kingma I, Vorster W. In vitro study of inter-individual variation in posterior slope in the knee joint. Clin Biomech (Bristol, Avon) 2009;24:488–492. doi: 10.1016/j.clinbiomech.2009.03.008. [DOI] [PubMed] [Google Scholar]
- 9.Engelina S, Antonios T, Robertson CJ, Killingback A, Adds PJ. Ultrasound investigation of vastus medialis oblique muscle architecture: an in vivo study. Clin Anat. 2014;27:1076–1084. doi: 10.1002/ca.22413. [DOI] [PubMed] [Google Scholar]
- 10.Fantozzi S, Catani F, Ensini A, Leardini A, Giannini S. Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily living. J Orthop Res. 2006;24:2222–2229. doi: 10.1002/jor.20306. [DOI] [PubMed] [Google Scholar]
- 11.Fregly BJ, Besier TF, Lloyd DG, Delp SL, Banks SA, Pandy MG, D’Lima DD. Grand challenge competition to predict in vivo knee loads. J Orthop Res. 2012;30:503–513. doi: 10.1002/jor.22023. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Fujimoto E, Sasashige Y, Tomita T, Iwamoto K, Masuda Y, Hisatome T. Significant effect of the posterior tibial slope on the weight-bearing, midflexion in vivo kinematics after cruciate-retaining total knee arthroplasty. J Arthroplasty. 2014;29:2324–2330. doi: 10.1016/j.arth.2013.10.018. [DOI] [PubMed] [Google Scholar]
- 13.Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng. 1983;105:136–144. doi: 10.1115/1.3138397. [DOI] [PubMed] [Google Scholar]
- 14.Heesterbeek PJC, Verdonschot N, Wymenga AB. In vivo knee laxity in flexion and extension: a radiographic study in 30 older healthy subjects. Knee. 2008;15:45–49. doi: 10.1016/j.knee.2007.09.007. [DOI] [PubMed] [Google Scholar]
- 15.In Y, Kim J-M, Woo Y-K, Choi N-Y, Sohn J-M, Koh H-S. Factors affecting flexion gap tightness in cruciate-retaining total knee arthroplasty. J Arthroplasty. 2009;24:317–321. doi: 10.1016/j.arth.2007.10.022. [DOI] [PubMed] [Google Scholar]
- 16.Jojima H, Whiteside LA, Ogata K. Effect of tibial slope or posterior cruciate ligament release on knee kinematics. Clin Orthop Relat Res. 2004;426:194–198. doi: 10.1097/01.blo.0000138960.57680.60. [DOI] [PubMed] [Google Scholar]
- 17.Marra MA, Vanheule V, Fluit R, Koopman BHFJM, Rasmussen J, Verdonschot N, Andersen MS. A subject-specific musculoskeletal modeling framework to predict in vivo mechanics of total knee arthroplasty. J Biomech Eng. 2015;137:20904. doi: 10.1115/1.4029258. [DOI] [PubMed] [Google Scholar]
- 18.Matziolis G, Mehlhorn S, Schattat N, Diederichs G, Hube R, Perka C, Matziolis D. How much of the PCL is really preserved during the tibial cut? Knee Surg Sports Traumatol Arthrosc. 2012;20:1083–1086. doi: 10.1007/s00167-011-1696-5. [DOI] [PubMed] [Google Scholar]
- 19.Oka S, Matsumoto T, Muratsu H, Kubo S, Matsushita T, Ishida K, Kuroda R, Kurosaka M. The influence of the tibial slope on intra-operative soft tissue balance in cruciate-retaining and posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2014;22:1812–1818. doi: 10.1007/s00167-013-2535-7. [DOI] [PubMed] [Google Scholar]
- 20.Okazaki K, Tashiro Y, Mizu-uchi H, Hamai S, T Doi, Iwamoto Y. Influence of the posterior tibial slope on the flexion gap in total knee arthroplasty. Knee. 2014;21:806–809. doi: 10.1016/j.knee.2014.02.019. [DOI] [PubMed] [Google Scholar]
- 21.Ostermeier S, Hurschler C, Windhagen H, Stukenborg-Colsman C. In vitro investigation of the influence of tibial slope on quadriceps extension force after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2006;14:934–939. doi: 10.1007/s00167-006-0078-x. [DOI] [PubMed] [Google Scholar]
- 22.Singerman R, Dean JC, Pagan HD, Goldberg VM. Decreased posterior tibial slope increases strain in the posterior cruciate ligament following total knee arthroplasty. J Arthroplasty. 1996;11:99–103. doi: 10.1016/S0883-5403(96)80167-7. [DOI] [PubMed] [Google Scholar]
- 23.Van Opstal N, Feyen H, Luyckx JP, Bellemans J. Mean tensile strength of the PCL in TKA depends on the preservation of the tibial insertion site. Knee Surg Sports Traumatol Arthrosc. 2016;24:273–278. doi: 10.1007/s00167-014-3377-7. [DOI] [PubMed] [Google Scholar]
- 24.Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994;299:31–43. [PubMed] [Google Scholar]
- 25.Whiteside LA, Amador DD. The effect of posterior tibial slope on knee stability after Ortholoc total knee arthroplasty. J Arthroplasty. 1988;3(Suppl):S51–S57. doi: 10.1016/S0883-5403(88)80009-3. [DOI] [PubMed] [Google Scholar]
- 26.Zelle J, Heesterbeek PJC, De Waal Malefijt M, Verdonschot N. Numerical analysis of variations in posterior cruciate ligament properties and balancing techniques on total knee arthroplasty loading. Med Eng Phys. 2010;32:700–707. doi: 10.1016/j.medengphy.2010.04.013. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.