Abstract
Background
In patients with bicuspid valve (BAV), ascending aorta (AAo) dilatation may be caused by altered flow patterns and wall shear stress (WSS). These differences may explain different aortic dilatation morphotypes. Using 4D-flow cardiovascular magnetic resonance (CMR), we aimed to analyze differences in flow patterns and regional axial and circumferential WSS maps between BAV phenotypes and their correlation with ascending aorta dilatation morphotype.
Methods
One hundred and one BAV patients (aortic diameter ≤ 45 mm, no severe valvular disease) and 20 healthy subjects were studied by 4D-flow CMR. Peak velocity, flow jet angle, flow displacement, in-plane rotational flow (IRF) and systolic flow reversal ratio (SFRR) were assessed at different levels of the AAo. Peak-systolic axial and circumferential regional WSS maps were also estimated. Unadjusted and multivariable adjusted linear regression analyses were used to identify independent correlates of aortic root or ascending dilatation. Age, sex, valve morphotype, body surface area, flow derived variables and WSS components were included in the multivariable models.
Results
The AAo was non-dilated in 24 BAV patients and dilated in 77 (root morphotype in 11 and ascending in 66). BAV phenotype was right-left (RL-) in 78 patients and right-non-coronary (RN-) in 23. Both BAV phenotypes presented different outflow jet direction and velocity profiles that matched the location of maximum systolic axial WSS. RL-BAV velocity profiles and maximum axial WSS were homogeneously distributed right-anteriorly, however, RN-BAV showed higher variable profiles with a main proximal-posterior distribution shifting anteriorly at mid-distal AAo. Compared to controls, BAV patients presented similar WSS magnitude at proximal, mid and distal AAo (p = 0.764, 0.516 and 0.053, respectively) but lower axial and higher circumferential WSS components (p < 0.001 for both, at all aortic levels). Among BAV patients, RN-BAV presented higher IRF at all levels (p = 0.024 proximal, 0.046 mid and 0.002 distal AAo) and higher circumferential WSS at mid and distal AAo (p = 0.038 and 0.046, respectively) than RL-BAV. However, axial WSS was higher in RL-BAV compared to RN-BAV at proximal and mid AAo (p = 0.046, 0.019, respectively). Displacement and axial WSS were independently associated with the root-morphotype, and circumferential WSS and SFRR with the ascending-morphotype.
Conclusions
Different BAV-phenotypes present different flow patterns with an anterior distribution in RL-BAV, whereas, RN-BAV patients present a predominant posterior outflow jet at the sinotubular junction that shifts to anterior or right anterior in mid and distal AAo. Thus, RL-BAV patients present a higher axial WSS at the aortic root while RN-BAV present a higher circumferential WSS in mid and distal AAo. These results may explain different AAo dilatation morphotypes in the BAV population.
Electronic supplementary material
The online version of this article (10.1186/s12968-018-0451-1) contains supplementary material, which is available to authorized users.
Keywords: Bicuspid aortic valve, 4D flow cardiovascular magnetic resonance (4D flow CMR), Wall shear stress, Ascending aorta, Aorta hemodynamics, Aortic dilatation
Background
Bicuspid aortic valve (BAV) is the most common congenital valvular abnormality, occurring in 1–2% of the general population [1]. Between 60 and 80% BAV patients develop aortic dilatation that is associated with an increased risk of aortic dissection and rupture [2, 3]. Aortic diameter alone has proved to be largely ineffective to predict these complications [4–6].
The most common BAV fusion phenotype involves the right and left cusps (RL-BAV) and is associated with dilatation of the tubular ascending aorta (AAo) and aortic root primarily along the convexity of the aorta. While the fusion of the right and non-coronary cusps (RN-BAV) induces arch dilatation with involvement of the tubular ascending aorta, with relative sparing of the root [3]. However, not all patients with the same BAV phenotype have the same pattern of aortopathy and, furthermore, 26–35% of BAV present a non-dilated aorta [2]. Therefore, other factors beyond valve phenotype may be related to aortic dilatation. Although controversy exists regarding the influence of hemodynamic [7, 8] and genetic factors in aortic dilatation [9], different studies have provided significant evidence that altered outflow pattern is related to aortic morphology [7, 10].
In recent years, time-resolved three-dimensional phase-contrast cardiovascular magnetic resonance (CMR 4D-flow) has emerged as a potential tool to provide comprehensive information on aortic hemodynamics with 3D visualization of blood-flow patterns [11, 12]. Using 4D-flow, several studies have analyzed flow and wall shear stress (WSS) on specific analysis planes in the ascending aorta [7, 11, 13, 14], and their relation to aortic dilatation [7]. Although some studies have analyzed WSS components [11, 13], their eventual association to different dilatation morphotype has not been investigated [11]. Only one study analyzed a BAV population differentiating between dilatation morphotype, but the computed WSS was not referenced to local direction [7]. Additionally, it has recently been shown that regions with increased WSS correspond to extracellular matrix dysregulation and elastic fiber degeneration in the ascending aorta and contribute to the development of aortopathy [8, 15, 16]. Thus, a more detailed 3D representation of WSS components [12, 17] may help to explain the different aortic dilatation morphotypes. However, there is not yet sufficient evidence to include these variables for clinical management [7, 11].
The aim of our study was to assess the relation between aortic flow patterns and axial and circumferential WSS by 4D flow CMR through the entire ascending aorta in a large BAV population, and to establish their association with aortic dilatation and morphotype.
Methods
Study population
Patients with RL- or RN-BAV phenotype, aortic root and AAo diameters ≤45 mm and no severe valvular disease (aortic regurgitation ≤ Grade III; aortic velocity < 3 m/s) by echo were consecutively and prospectively recruited. Inclusion criteria were: age > 18 years, no cardiovascular disease, sinus rhythm, no hypertension, no connective tissue disorders, no aortic coarctation or other congenital heart diseases and no contraindication for CMR. Also, 20 healthy subjects matched with the BAV population in age and aortic diameters were studied. The study was approved by the local ethics committee and informed consent was obtained from all participants.
Cardiovascular magnetic resonance protocol
CMR studies were performed on a 1.5 T scanner (Signa, General Electric Healthcare, Waukesha, Wisconsin, USA). The protocol included 2D balanced steady-state free-precession (bSSFP) cine imaging which was used to assess BAV phenotype and aortic diameters (using the double-oblique multiplanar reconstruction), and a 4D-flow acquisition with retrospective electrocardiogram (ECG)-gating during free-breathing. Endovenous contrast was not given.
For 4D-flow CMR, phase-contrast (PC) VIPR sequence [18], a radially undersampled acquisition with 5-point balanced velocity encoding was used [19]. The acquisition volume was set to include the entire thoracic aorta. Acquisitions were made with an eight-channel cardiac coil (HD Cardiac, GE Healthcare) using the following parameters: velocity encoding (VENC) 200 cm/s, field of view (FOV) 400x400x400 mm, scan matrix 160 × 160 × 160 (voxel size of 2.5 × 2.5 × 2.5 mm3), flip angle 8°, repetition time 4.2–6.4 ms and echo time 1.9–3.7 ms. This data set was reconstructed the nominal temporal resolution of each patient and was (5xTR) 21 ms–32 ms. Reconstructions were performed offline with corrections for background phase from concomitant gradients and eddy currents, and trajectory errors of the 3D radial acquired k-space [19, 20].
Data analysis: 4D flow data processing
Eight double-oblique analysis planes were equally distributed in the AAo between the sinotubular junction and the origin of the brachiocephalic trunk (see red and blue lines on the left side of Fig. 1b). The vessel lumen was manually segmented in every analysis plane for all systolic phases using an angiogram derived from the 4D-flow data using complex difference processing [21]. Mass Research Software (Leiden University Medical Center, Leiden, the Netherlands) was used for the location of the analysis planes and lumen segmentation. Lumen contour points and 3D velocity data for each plane were exported for calculations to be made using custom Matlab software (MathWorks Inc., Natick, Massachusetts, USA).
Flow parameters
Peak velocity, flow jet angle, normalized flow displacement, and in-plane rotational flow were calculated at 3 different levels at the proximal, mid and distal AAo (blue lines on Fig. 1b). Flow parameters were averaged using 1 time-frame before and 2 frames after peak systole to mitigate noise.
Flow jet angle and normalized flow displacement were obtained as described by Sigovan et al. [22]. In-plane rotational flow was quantified as the through-plane component (ΓT) of circulation (Γ), which is a parameter used in fluid dynamics to quantify rotation of flow within a plane. To this aim, vorticity (ω) was computed in each double-oblique analysis plane and circulation (Γ) was obtained as the integral of vorticity with respect to cross-sectional area, Γ = ∬ ω dS [23].
Flow volumes were calculated as the time-integral over systolic phases of forward and backward through-plane flow rate curves, and used for the calculation of systolic flow reversal ratio (SFRR) [24] at mid and distal AAo (Figs. 1 and 2).
Where vSFF and vSBF represent the forward and backward flow rates, respectively, and Ts is systolic time interval.
Wall shear stress
Peak-systolic WSS vectors (averaged from 1-time frame before, and 2-time frames after peak) were calculated at 64 points equally distributed along the aortic lumen for the 8 cross sectional analysis planes by fitting the 3D velocity data with B-spline surfaces and computing velocity derivatives on the segmented vessel lumen [25]. WSS vectors were decomposed in their through-plane (axial) and in-plane (circumferential) components.
Contour-averaged magnitude (WSSmag,avg) and WSS components (WSSax,avg and WSScirc,avg) were calculated at proximal, mid and distal AAo.
Averaged WSS maps were obtained for each BAV phenotype and dilatation morphotype (Figs. 1c, 6 and 8). To this aim, the 64 points of the lumen contour per cross-sectional plane were aligned for all patients using the inner aortic curvature as a reference. Averaged WSS maps were calculated by computing point-to-point WSS means for all the 8 sections analyzed. Finally, statistical significance maps of axial and circumferential WSS were calculated for the mean WSS value for 8 standardized angular segments [14] of the aortic wall. Averaged WSS maps and statistical significance maps were visualized using bilinear interpolation.
Dilatation morphotypes
In order to determine the presence of aortic root or ascending dilatation, aortic diameters were adjusted with a logarithm transformation to set the z-score for both sinuses (zsinus) and ascending aorta (zAscAo) accounting for sex, age and body surface area (BSA) as described by Campens et al. [26]. Using a z-score cutoff for aortic dilatation of 2 standard error of estimate, patients were categorized according to the tract predominantly or exclusively involved in dilatation according to Della Corte’s classification [2]. Thus, patients were classified as non-dilated (zsinus≤2 and zAscAo≤2), root-morphotype (zsinus> 2 and zsinus>zAscAo) or ascending-morphotype (zAscAo> 2 and zAscAo>zsinus).
Statistical analysis
Continuous demographic variables were expressed as mean ± standard deviation. The Kolmogorov-Smirnov test was used to evaluate the normality distribution of variables. Differences between groups for continuous parameters were assessed by Student’s t-test if they presented a normal distribution or ANOVA with Bonferroni correction for multiple comparisons, and Mann-Whitney U test if they did not present a normal distribution. For categorical variables, general characteristics of the sample were assessed by percentages (chi-square test). Logarithmic transformation (ln) was performed for variables with both positive and negative values (such as circulation and WSS) to preserve the distinction between negative, zero and positive values as described by Whittaker et al. [27].
Multivariable logistic regression analyses with a forward selection procedure were used to evaluate specific relations between demographic and flow variables and aortic root or ascending dilatation. Variables were entered into the model if P < 0.25 in univariate analyses. The aortic root morphotype was compared to the rest of groups (non-dilated and ascending), whereas, the ascending group was compared to non-dilated and root morphotype as described elsewhere [28]. To avoid multicollinearity, variables were excluded from the multivariable logistic regression if the tolerance test was < 0.1 or the variation inflation factor > 5. This is the case of the same flow variables computed at different locations. The variables entered the multivariable model were chosen as those demonstrating better predictive value, i.e. those having higher AUC in the Receiver operating characteristic (ROC) curve, as compared to the same variable computed at another location. ROC curves were performed to assess the relationship between variables obtained in the multivariable analysis and aortic morphotypes.
A two-tailed P value < 0.05 was considered statistically significant. SPSS (version 19.0, International Business Machines, Armonk, New York, USA) was used for the analysis.
Results
One hundred and one BAV patients (78 RL- and 23 RN-phenotype) and 20 healthy subjects completed the study protocol. Demographic characteristics and aortic diameters among groups are shown in Table 1. Demographics did not significantly differ among the three groups (controls, RN-BAV, RL-BAV). Although aortic diameters were larger in BAV compared to controls, no statistically-significant differences were observed. However, z-scores were higher in the RL-BAV phenotype at the sinuses of Valsalva and at the AAo in the RN-BAV.
Table 1.
Healthy Controls | RL-BAV | RN-BAV | p-value | |
---|---|---|---|---|
N | 20 | 78 | 23 | |
Age (years) | 50.04 ± 16.39 | 48.43 ± 13.15 | 46.97 ± 16.00 | 0.659 |
Men (%) | 73.30 | 62.80 | 65.20 | 0.736 |
Weight (kg) | 78.57 ± 9.24 | 76.17 ± 10.38 | 76.17 ± 10.38 | 0.270 |
Height (cm) | 169.42 ± 7.73 | 170.00 ± 10.66 | 172.00 ± 9.91 | 0.433 |
Body Surface Area (m2) | 1.89 ± 0.13 | 1.83 ± 0.21 | 1.88 ± 0.16 | 0.278 |
Degree of Aortic Regurgitation (%) | 0.240 | |||
0 | – | 26.8 | 35.3 | |
1 | – | 21.1 | 5.9 | |
2 | – | 49.3 | 47.0 | |
3 | – | 2.8 | 11.8 | |
Degree of Aortic Stenosis (%) | 0.695 | |||
Absent | – | 92.9 | 90 | |
Mild | – | 5.7 | 10 | |
Moderate | – | 1.4 | 0 | |
Maximum aortic velocity (m/s) | 97.34 ± 19.0 | 111.15 ± 24.35 | 119.32 ± 21.22 | 0.067 |
Mean pressure gradient (mm Hg) | 3.24 ± 1.21 | 4.9 ± 1.13 | 5.69 ± 1.71 | 0.074 |
Systolic Arterial Pressure (mm Hg) | 136.26 ± 19.47 | 134.18 ± 17.32 | 142 ± 17.76 | 0.064 |
Diastolic Arterial Pressure (mm Hg) | 76.73 ± 8.85 | 75.72 ± 9.06 | 79.69 ± 9.11 | 0.133 |
Sinus of Valsalva Diameter (mm) | 32.77 ± 3.44 | 36.68 ± 5.10 | 34.78 ± 2.69 | 0.796 |
Ascending Aorta Diameter (mm) | 35.58 ± 2.96 | 39.86 ± 7 .51 | 40.30 ± 6.10 | 0.070 |
z-score sinus of Valsalva diameter | 0.01 ± 0.84 | 1.41 ± 1.29 | 0.82 ± 1.11 | 0.001 |
z-score ascending aorta diameter | 0.02 ± 0.71 | 2.87 ± 1.71 | 3.03 ± 1.4 | < 0.001 |
P-values reported are the result of ANOVA comparison between 3 groups: controls, RL-BAV and RN-BAV in continuous variables and Chi-square test for categorical variables
In the RL-BAV group (n = 78), 20 patients (25.6%) presented a non-dilated, 10 (12.8%) a root- and 48 (61.5%) an ascending-morphotype aorta. In the RN-BAV group (n = 23), 4 patients (17.4%) presented a non-dilated, 1 (4.3%) a root- and 18 (78.3%) an ascending-morphotype. Only three of the patients with root-morphotype did not present ascending aorta dilatation (zAscAo< 2). These root-only dilated patients were all men (mean age 40 years), RL-BAV and presented different degrees of aortic regurgitation and no aortic stenosis.
Peak velocity and flow eccentricity
Through-plane and magnitude velocity, jet angle and normalized displacement at proximal, mid and distal AAo are shown in Table 2. Compared to healthy control subjects, BAV patients presented higher through-plane velocity values at proximal AAo, and higher velocity magnitude, jet angle and flow displacement at the proximal and mid AAo but not in the distal part (Fig. 3). Also, RN- compared to RL-BAV presented significant differences in peak velocity and eccentricity at proximal AAo.
Table 2.
Total population | BAV phenotype | Ascending aorta morphotype (only BAV) |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Plane | Measurements | CONTROLS (n = 20) |
BAV (n = 101) |
p | RL-BAV (n = 78) |
RN-BAV (n = 23) |
p | Non-dilated (n = 24) |
Root (n = 11) |
Ascending (n = 66) |
p |
Prox | Peak velocity magnitude (cm/s) | 111.7 ± 21.9 | 133.9 ± 28.3 | 0.004 | 128.5 ± 27.7 | 152.4 ± 22.2 | 0.001 | 122.6 ± 26.8 | 134.0 ± 23.9 | 138.0 ± 28.8 | 0.073 |
Peak TP velocity (cm/s) | 97.3 ± 19 | 113.0 ± 23.8 | 0.020 | 111.2 ± 24.4 | 119.3 ± 21.2 | 0.112 | 106.8 ± 26.1 | 113.4 ± 22.0 | 115.2 ± 23.2 | 0.343 | |
Jet angle (°) | 24.3 ± 6.2 | 25.7 ± 12.1 | 0.666 | 23.3 ± 11.3 | 33.8 ± 11.8 | < 0.0001 | 21.1 ± 14.0 | 24.2 ± 13.8 | 27.7 ± 10.8 | 0.042 | |
Normalized displacement | 0.04 ± 0.02 | 0.15 ± 0.07 | < 0.001 | 0.15 ± 0.06 | 0.12 ± 0.06 | 0.045 | 0.10 ± 0.06 | 0.12 ± 0.05 | 0.16 ± 0.05 | < 0.0001 | |
IRF (cm2/s) | −22.9 ± 65.9 | 139.1 ± 143.5 | < 0.001 | 123.0 ± 128.4 | 193.4 ± 178.3 | 0.024 | 54.2 ± 124.3 | 162.3 ± 162.4 | 166.1 ± 136.5 | 0.001 | |
WSSmag,avg (N/m2) | 0.52 ± 0.09 | 0.56 ± 0.16 | 0.764 | 0.55 ± 0.15 | 0.57 ± 0.17 | 0.789 | 0.53 ± 0.14 | 0.55 ± 0.18 | 0.56 ± 0.15 | 0.608 | |
WSSax,avg (N/m2) | 0.41 ± 0.11 | 0.18 ± 0.12 | < 0.001 | 0.19 ± 0.11 | 0.13 ± 0.09 | 0.046 | 0.26 ± 0.14 | 0.21 ± 0.11 | 0.14 ± 0.08 | 0.001 | |
WSScirc,avg (N/m2) | −0.03 ± 0.11 | 0.30 ± 0.20 | < 0.001 | 0.29 ± 0.18 | 0.31 ± 0.35 | 0.590 | 0.18 ± 0.22 | 0.32 ± 0.20 | 0.33 ± 0.18 | 0.007 | |
Mid | Peak velocity magnitude (cm/s) | 93.1 ± 24.3 | 118.8 ± 31.1 | 0.002 | 116.8 ± 32.3 | 125.8 ± 26.0 | 0.232 | 110.4 ± 22.7 | 114.5 ± 30.1 | 122.6 ± 33.5 | 0.282 |
Peak TP velocity (cm/s) | 89.7 ± 24.3 | 100.7 ± 27.7 | 0.060 | 101.0 ± 30.3 | 99.5 ± 16.5 | 0.833 | 99.0 ± 22.7 | 95.8 ± 22.8 | 102.0 ± 30.1 | 0.877 | |
Jet angle (°) | 10.2 ± 5.9 | 28.7 ± 11.4 | < 0.001 | 28.3 ± 12.0 | 30.1 ± 8.8 | 0.384 | 23.0 ± 10.6 | 25.4 ± 10.3 | 31.4 ± 11.0 | 0.001 | |
Normalized displacement | 0.03 ± 0.01 | 0.09 ± 0.06 | < 0.001 | 0.09 ± 0.06 | 0.09 ± 0.04 | 0.639 | 0.07 ± 0.06 | 0.06 ± 0.04 | 0.11 ± 0.06 | 0.001 | |
IRF (cm2/s) | 35.1 ± 50.7 | 199.6 ± 190.3 | < 0.001 | 186.2 ± 177.4 | 245.0 ± 227.4 | 0.046 | 101.1 ± 94.4 | 190.8 ± 200.2 | 236.9 ± 203.5 | 0.003 | |
WSSmag,avg (N/m2) | 0.54 ± 0.15 | 0.58 ± 0.21 | 0.516 | 0.57 ± 0.21 | 0.59 ± 0.22 | 0.907 | 0.55 ± 0.16 | 0.56 ± 0.21 | 0.59 ± 0.23 | 0.888 | |
WSSax,avg (N/m2) | 0.46 ± 0.14 | 0.29 ± 0.14 | < 0.001 | 0.30 ± 0.13 | 0.23 ± 0.11 | 0.019 | 0.37 ± 0.17 | 0.30 ± 0.12 | 0.25 ± 0.10 | 0.010 | |
WSScirc,avg (N/m2) | 0.06 ± 0.07 | 0.29 ± 0.22 | < 0.001 | 0.27 ± 0.20 | 0.34 ± 0.26 | 0.038 | 0.17 ± 0.17 | 0.28 ± 0.24 | 0.33 ± 0.21 | 0.004 | |
SFRR (%) | 3.99 ± 3.74 | 20.9 ± 13.5 | < 0.001 | 21.4 ± 14.6 | 19.2 ± 8.7 | 0.777 | 12.3 ± 12.7 | 15.0 ± 11.7 | 25.0 ± 12.3 | < 0.0001 | |
Dist | Peak velocity magnitude (cm/s) | 96.3 ± 21.6 | 106.1 ± 30.0 | 0.195 | 105.0 ± 30.2 | 109.8 ± 29.4 | 0.439 | 105.7 ± 20.4 | 107.5 ± 30.7 | 106.0 ± 33.0 | 0.991 |
Peak TP velocity (cm/s) | 87.4 ± 18.1 | 85.6 ± 23.6 | 0.886 | 86.7 ± 23.3 | 81.8 ± 24.7 | 0.388 | 91.1 ± 19.0 | 88.3 ± 22.4 | 83.1 ± 25.1 | 0.374 | |
Jet angle (°) | 23.0 ± 9.0 | 24.0 ± 10.6 | 0.690 | 25.1 ± 10.8 | 20.4 ± 9.5 | 0.138 | 19.5 ± 6.6 | 24.1 ± 9.1 | 25.6 ± 11.6 | 0.051 | |
Normalized displacement | 0.03 ± 0.01 | 0.06 ± 0.04 | 0.027 | 0.06 ± 0.04 | 0.05 ± 0.03 | 0.749 | 0.05 ± 0.03 | 0.06 ± 0.05 | 0.06 ± 0.04 | 0.813 | |
IRF (cm2/s) | 36.6 ± 35.3 | 120.9 ± 140.0 | 0.013 | 96.2 ± 117.8 | 204.7 ± 176.1 | 0.002 | 60.7 ± 70.8 | 106.1 ± 178.3 | 145.2 ± 146.7 | 0.005 | |
WSSmag,avg (N/m2) | 0.58 ± 0.13 | 0.50 ± 0.18 | 0.053 | 0.48 ± 0.16 | 0.53 ± 0.20 | 0.333 | 0.48 ± 0.15 | 0.53 ± 0.18 | 0.49 ± 0.18 | 0.767 | |
WSSax,avg (N/m2) | 0.36 ± 0.13 | 0.24 ± 0.12 | 0.001 | 0.25 ± 0.12 | 0.22 ± 0.10 | 0.356 | 0.28 ± 0.16 | 0.27 ± 0.11 | 0.22 ± 0.09 | 0.082 | |
WSScirc,avg (N/m2) | 0.07 ± 0.05 | 0.22 ± 0.19 | < 0.001 | 0.19 ± 0.17 | 0.29 ± 0.22 | 0.046 | 0.13 ± 0.13 | 0.19 ± 0.24 | 0.25 ± 0.19 | 0.020 | |
SFRR (%) | 2.63 ± 3.47 | 10.9 ± 9.0 | < 0.001 | 11.5 ± 9.6 | 9.1 ± 5.8 | 0.469 | 9.3 ± 11.6 | 8.3 ± 5.5 | 11.9 ± 8.3 | 0.026 |
Values are mean ± SD
TP through-plane, BAV bicuspid aortic valve, RL right-left, RN right-non coronary, IRF in-plane rotational flow, WSS wall shear stress, WSSmag, avg. contour-averaged WSS magnitude, WSSax, avg. contour-averaged axial WSS, WSScirc, avg. contour-averaged circumferential WSS, SFRR systolic flow reversal ratio
When the aortic morphotype was considered in BAV, the ascending and root-morphotypes (dilated morphotype) compared to the non-dilated presented higher jet angles and displacement at the proximal and mid AAo (P < 0.05). However, the ascending versus the root-morphotypes did not present differences (Table 2).
When the location of the center of velocities and flow direction were analyzed in BAV, RL-BAV presented a consistent pattern (Fig. 3), showing a right (28% cases) to right-anterior position (55% cases) in the proximal aorta, with a similar profile in the mid segment and an axisymmetric profile at the distal AAo (Fig. 4a and additional movie file [Additional file 1]). However, RN-BAV presented a higher variability in their flow pattern (Fig. 3) with a predominant posterior to right-posterior outflow jet (78% cases) in the proximal aorta that shifted to the anterior segments (55% right-anterior and 20% anterior) in the mid and distal AAo (Fig. 4b and additional movie file [Additional file 2]). Control patients presented non-eccentric and predominantly laminar flow (see additional movie file [Additional file 3]).
In-plane rotational flow and systolic flow reversal ratio
In-plane rotational flow (IRF) was significantly higher in RN- compared to RL-phenotype at all aortic levels. Although a trend for higher SFRR was observed in RL-BAV compared to RN-BAV, these differences did not reach statistical significance (Table 2).
Dilated BAV presented higher values of IRF and SFRR compared to healthy controls or non-dilated morphotype (Table 2, Fig. 5). IRF was mostly right-handed (98%) in all aortic morphotypes with no statistically-significant differences. However, patients with the ascending-morphotype presented higher IRF and SFRR than the root-morphotype at all aortic levels (Table 2) (Fig. 5).
WSS and regional WSS maps
Compared to controls, BAV presented similar magnitude (WSSmag,avg) (P > 0.05) but lower axial (WSSax,avg) and higher circumferential WSS (WSScirc,avg) at all levels (P < 0.001) (Table 2).
According to the valve phenotype, RL- compared to RN-BAV presented higher WSSax,avg in proximal and mid AAo (P < 0.05), whereas WSScirc,avg was higher in RN-phenotype in mid and distal AAo (Table 2). These differences were also observed in regional WSS maps (Figs. 6 and 7).
Based on the aortic morphotype, non-dilated BAV presented similar WSSmag avg and WSSax,avg but higher WSScirc,avg compared to controls at all levels (P < 0.05). In BAV patients, the WSSmag,avg was similar among the different aortic morphotypes. However, WSSax,avg was significantly higher in the root-morphotype and WSScirc,avg was higher in the ascending-morphotype at all levels (Table 2). Regional differences (p < 0.05) between morphotypes were more pronounced for circumferential than axial WSS, and were associated with regions of systolic flow reversal for axial WSS (Figs. 8 and 9).
The outflow jet direction matched the location of maximum systolic axial WSS in the aortic wall (Figs. 3 and 6). Thus, in RN-BAV, maximum systolic axial WSS extends from posterior to right-posterior proximally towards anterior to right-anterior in mid and distal AAo. However, in RL-BAV, maximum systolic axial WSS extends from right to right-anterior at all aortic levels (Figs. 6 and 7).
Correlates of root or ascending-morphotypes
Significant bivariable (unadjusted) and multivariable adjusted correlates of aortic dilatation (> 2 z-score) [26] in BAV are listed in Table 3 (variables selected from the 4D-flow-derived variables listed in Table 2 and including sex, age and body surface area). Displacement, IRF and WSS were transformed to their natural logarithms.
Table 3.
Root morphotype | Univariate adjusted correlates of root morphotype | Multivariable adjusted correlates of root morphotype | ||
OR | p-value | OR | p-value | |
Age | 0.99 (0.96–1.02) | 0.530 | ||
BSA | 0.17 (0.02–1.45) | 0.104 | 0.08 | 0.291 |
BAV phenotype (RN vs RL) |
1.41 (1.17–2.28) | 0.005 | 1.35 | 0.998 |
Sex (male) | 1.59 (1.32–1.95) | 0.050 | 1.25 | 0.011 |
Proximal peak velocity magnitude (cm/s) | 1.01 (0.98–1.22) | 0.719 | ||
Proximal jet angle (°) | 1.03 (0.95–1.51) | 0.490 | ||
Ln Proximal normalized displacement | 1.98 (1.01–2.93) | 0.040 | 1.1 | 0.009 |
Ln Proximal IRF (cm2/s) | 1.22 (1.02–1.45) | 0.002 | 0.79 | 0.940 |
Ln Proximal WSSmag,avg (N/m2) | 1.54 (0.09–4.52) | 0.761 | ||
Ln Proximal WSSax,avg (N/m2) | 1.621 (0.93–2.95) | 0.081 | 1.13 | 0.003 |
Ln Proximal WSScirc,avg (N/m2) | 2.76 (0.41–4.71) | 0.243 | 0.02 | 0.673 |
Ascending morphotype | Univariate adjusted correlates of ascending morphotype | Multivariable adjusted correlates of ascending morphotype | ||
OR | p-value | OR | p-value | |
Age | 0.99 (0.96–1.03) | 0.917 | ||
BSA | 2.51 (0.30–2.17) | 0.398 | ||
BAV phenotype (RN vs RL) |
1.99 (1.61–3.48) | 0.026 | 1.73 | 0.04 |
Sex (male) | 0.82 (0.32–2.10) | 0.678 | ||
Mid jet angle (°) | 1.09 (1.03–1.14) | 0.001 | 1.025 | 0.353 |
Ln Mid normalized displacement | 2.85 (1.56–5.23) | 0.001 | 1.510 | 0.270 |
Ln Mid IRF (cm2/s) | 2.98 (1.54–5.78) | 0.001 | 1.195 | 0.802 |
Ln Mid WSSax,avg (N/m2) | 0.14 (0.04–0.48) | 0.221 | 0.960 | 0.950 |
Ln Mid WSScirc,avg (N/m2) | 1.51 (1.16–3.68) | 0.002 | 1.61 | 0.011 |
Mid SFRR (%) | 1.12 (1.06–1.19) | 0.001 | 1.11 | 0.001 |
On multivariable analysis, only sex (male), natural logarithms of displacement and WSSax,avg were related to the presence of the root-morphotype with an AUC: 0.91 (P < 0.001) (Fig. 10). However, RN-phenotype, SFRR and WSScirc,avg in the mid AAo were related to the presence of the ascending- morphotype with an AUC: 0.89 (P < 0.001) (Table 3) (Fig. 10).
Discussion
In our study, we assessed the relation between aortic flow patterns and regional WSS components (magnitude, axial and circumferential) through the entire ascending aorta in a large BAV population. In order to avoid the effect of changes in flow dynamics and WSS secondary to aortic dilatation [29] or severe valvular disease, only BAV patients with non-severe valvular dysfunction and aortic diameters ≤45 mm were included. Also, the specific role of flow parameters and WSS components in the ascending aorta dilatation and morphotype was assessed by unadjusted and multivariable adjusted analysis.
The main findings of our study were that: 1) RL-BAV patients present a sustained flow towards the anterior and right-anterior aortic walls, whereas, RN-BAV present a predominantly posterior output flow that shifts towards the right and right-anterior walls in the mid and distal AAo inducing an increase in the IRF. This flow distribution reflects into regional WSS patterns. 2) Sex (male), normalized displacement and axial WSS in the proximal AAo are the main factors associated with the root-morphotype, whereas RN-phenotype, SFRR and circumferential WSS are the main factors related to the ascending-morphotype.
To our knowledge, this is the first large study conducted in BAV patients in which different patterns of axial and circumferential regional WSS maps were used to explain variations in the AAo dilatation morphotype. Previous studies have emphasized differences in flow variables and WSS between the RN- and RL-BAV [7, 10, 11, 13, 14] with little or no correlation with the aortic dilatation morphotype [7, 11]. In this regard, Mahadevia et al. [7] did not analyze rotational flow or WSS components when studying BAV aortopathy, while Bissell et al. [11] only showed an increased rotational flow at larger aortic diameters suggesting a potential causative role. Thus, it is of great interest to ascertain the main factors associated with aortic dilatation since aortic diameter and structural changes in the aortic wall are related to clinical events regardless of valve phenotype [6, 8].
Flow patterns
Owing to the asymmetric valve opening, there is an increase in the jet angle and in the displacement of the center of velocities with respect to the center of the lumen that induces an asymmetric distribution of the WSS pattern as previously described [7, 11, 13, 14]. Similar to those of Mahadevia et al. [7], our results confirm that the jet angle is wider in RN-phenotype, whereas normalized displacement is greater in the RL-phenotype. Also, we demonstrated that these variables are greater at the proximal aorta with a progressive reduction at the distal AAo that suggests that flow tends to be more symmetric in the distal AAo. Our results differ from those of Mahadevia et al. [7] since they reported flow angle and displacement to be the main factors involved in AAo dilatation. However, they determined the absolute value of the displacement, whereas we report this value normalized by aortic diameter as suggested elsewhere [22].
In-plane rotational flow and SFRR
Similar to previous studies [11, 13, 30, 31], we found that BAV presented greater rotational flow compared to controls, with the RN-phenotype being greater than in RL- at the mid and distal AAo. This finding can be justified by the fact that the flow shifts from posterior towards anterior segments in RN-BAV. This rotational flow is not only significantly greater in RN-BAV but also in those with the ascending-morphotype. An increased rotational flow induces an increase in the circumferential WSS which justifies that both parameters were statistically significant in the ascending-morphotype on univariable analysis.
In our population, most of the BAV patients presented right-handed flow (98%). The lack of left handed helical flow seen in our study could be a sign of left handed helical flow being associated with severe/late disease process [11], and therefore, not seen in the benign aortopathy population (≤ 45 mm) included in our study.
The presence of retrograde flow at systole has been reported in patients with greater aortic diameters [29, 32, 33]. We found that higher values of SFRR are associated with the ascending-morphotype and not with the root-morphotype. An increase in the SFRR may induce an asymmetric increase and directional variations in the WSS contributing to dilatation. It is not clear whether this parameter is the cause or consequence of aortic dilatation; however, we observed that this cranio-caudal flow also exists in BAV with normal aortic diameters. This finding suggests that this flow may act as a causal agent of aortic dilatation and would increase as the aorta dilates, thereby perpetuating this process.
WSS and aortic dilatation
Our study is consistent with previous publications [7, 13] which suggest that the magnitude of WSS lacks significance since its value is similar in controls and BAV. However, controls present increased axial WSS because of predominant laminar flow, while helical flow in BAV increases circumferential WSS [13]. Thus, the different WSS components (axial and circumferential) constitute an interesting parameter in the assessment of aortic dilatation [11].
A detailed analysis of WSS permitted us to use a 3D representation of axial and circumferential WSS maps along the AAo, showing asymmetrical patterns that may contribute to structural changes in the aortic wall (elastin and metalloproteinases) related to aortic dilatation [8]. Furthermore, the presence of eccentric but uniform flow along the anterior AAo in the RL-phenotype determines that the axial component of WSS is greater in this subgroup of patients; however, the eccentric but helical flow in the RN-phenotype determines that the circumferential component of WSS is greater in this subgroup. This variation in WSS components may also influence the aortic morphotype. Thus, patients with a greater axial component exhibit more dilatation at the aortic root; however, greater circumferential WSS is associated with dilatation in the AAo.
Despite the correlations found here and elsewhere, the causative role of the observed flow disturbances need to be assessed in longitudinal studies. In particular, it has been mainly discussed in root only dilatation in BAV, which is thought to be a predominantly genetic form of BAV disease [9]. Our data confirmed the previously found association between root (only) dilatation and male sex [2].
The association of male sex, normalized displacement, and axial WSS in the proximal aorta discriminated the root-morphotype with an AUC of 0.91. However, the combination of an RN-phenotype, circumferential WSS and SFRR discriminated the ascending-morphotype with an AUC of 0.89. Thus, we believe these parameters should be considered in the evaluation of BAV beyond aortic diameters. This additional information could identify patients at higher risk of aortopathy that may require a closer follow-up.
Limitations
The prospective nature of our study determined the inclusion of more patients with the RL-phenotype than RN-; however, our cohort reflects the distribution of fusion phenotypes in the general BAV population.
Healthy subjects were recruited to match BAV patients for age and aortic diameters. Although aortic diameters were slightly larger in BAV, these differences were not statistically significant.
Owing to the limited spatial and temporal resolution of 4D-flow, WSS is known to be underestimated [25, 34, 35]. However, all acquisitions were made with the same imaging parameters and analyzed with the same methodology and previous work highlighted that regions of high/low WSS are matched despite different spatial and temporal resolutions [35]. Additionally, manual segmentation causes intra- and inter-observer variability. Nevertheless, the robustness of WSS measurements employed in this study and their reproducibility has been previously demonstrated [36].
WSS estimation was limited to 8 slices in the AAo at peak systole. Thus, very localized regions of altered WSS may have been lost and temporal variations were not assessed. The use of a volumetric WSS method [37, 38], would allow a more detailed analysis.
Despite flow variables are likely to vary during the ejection phase, our measurements of jet angle, flow displacement, IRF and WSS were performed only at peak systole. Moreover, these measurements were performed averaging the results obtained at four successive time instants to reduce noise. Despite this approach has been used by several authors [7, 11, 13], and have proved high reproducibility [38], it may imply the loss of possible information contained in other systolic phases.
We conducted a cross-sectional study to evaluate the impact of flow dynamics in aortic dilatation in BAV. However, the real influence of these parameters on the concurrence of aortic dilatation needs to be determined in further longitudinal studies.
Conclusions
BAV patients present altered flow patterns that vary depending on their valvular phenotype. RL-BAV patients present an anterior distribution, whereas, RN-BAV present a predominant posterior outflow jet at the sinotubular junction that shifts to anterior or right anterior in mid and distal AAo. This flow distribution induces an increase in the WSSax avg in the anterior aortic wall in RL-BAV patients, while, an increase in the in-plane rotational flow and WSScirc avg in the mid and distal AAo in RN-BAV patients. These results may explain different AAo dilatation morphotypes in the BAV population. Thus, in addition to aortic diameters, the assessment of the different WSS components (axial and circumferential) and derived flow parameters may contribute to identify more completely, and precisely which patients have a higher risk of aortic dilatation. The follow-up of our series will permit validation of our results.
Additional files
Acknowledgements
We would like to thank Christopher François (University of Wisconsin-Madison) and Rob van der Geest (Leiden University Medical Center) for advice on 4D-flow sequences, and Roberto García Álvarez (GE Healthcare) for technical support. We are also grateful to Augusto Sao Avilés for statistical analysis and Christine O’Hara for English revisions.
Funding
This study has been funded by Instituto de Salud Carlos III through the project PI11/01081, La Marató de TV3 (project number 20151330), and by Ministerio de Economía y Competitividad through Retos-Colaboración 2016 (RTC-2016-5152-1). Guala A. has received funding from the European Union Seventh Framework Programme FP7/People under grant agreement n° 267128.
Availability of data and materials
The datasets generated and analyzed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- 4D-flow
Time-resolved three-dimensional phase-contrast magnetic resonance imaging
- AAo
Ascending aorta
- BAV
Bicuspid aortic valve
- bSSFP
Balanced steady state free precession
- CMR
Cardiovascular magnetic resonance
- ECG
Electrocardiogram
- FOV
Field of view
- IRF
In-plane rotational flow
- PC
Phase contrast
- RL-BAV
Bicuspid aortic valve with fusion of the right and left coronary cusps
- RN-BAV
Bicuspid aortic valve with fusion of the right coronary cusp and the non-coronary cusp
- ROC
Region of interest
- SFRR
Systolic flow reversal ratio
- VENC
Velocity encoding
- WSS
Wall shear stress
- WSSax avg
Circumferentially-averaged axial WSS
- WSScirc avg
Circumferentially-averaged circumferential WSS
- WSSmag avg
Circumferentially-averaged magnitude WSS
Authors’ contributions
JFR and LD: conception and design, analysis and interpretation of data, drafting the manuscript. RK, GT, LG, AG: analysis and interpretation of data. GM, FV: data collection, analysis and interpretation of data. MH: data collection. LGu, TG: selection of patients based on echo criteria, analysis and interpretation of data. KJ and OW: provided and maintained the 4D flow sequence, analysis and interpretation of data. DG: conception and design. AE: conception and design, analysis and interpretation of data. All authors critically reviewed the manuscript and approved the final version.
Ethics approval and consent to participate
The study was approved by the local ethics committee (Hospital Universitari Vall d’Hebron) and informed consent was obtained from all participants.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Footnotes
Electronic supplementary material
The online version of this article (10.1186/s12968-018-0451-1) contains supplementary material, which is available to authorized users.
Contributor Information
José Fernando Rodríguez-Palomares, Phone: +3493 4893000, Email: jfrodriguezpalomares@gmail.com, Email: jfrodrig@vhebron.net.
Lydia Dux-Santoy, Email: lydia.dux@gmail.com.
Andrea Guala, Email: andrea.guala@yahoo.com.
Raquel Kale, Email: raquelkm93@gmail.com.
Giuliana Maldonado, Email: giulymaldonado@hotmail.com.
Gisela Teixidó-Turà, Email: gteixido@vhebron.net.
Laura Galian, Email: lauragaliangay@gmail.com.
Marina Huguet, Email: marina.huguet@quironsalud.es.
Filipa Valente, Email: filipaxaviervalente@gmail.com.
Laura Gutiérrez, Email: lauraguga@gmail.com.
Teresa González-Alujas, Email: mtegonzalez@vhebron.net.
Kevin M. Johnson, Email: kmjohnson3@wisc.edu
Oliver Wieben, Email: owieben@wisc.edu.
David García-Dorado, Email: dgdorado@vhebron.net.
Arturo Evangelista, Email: aevangel@vhebron.net.
References
- 1.Tzemos N, Therrien J, Thanassoulis G, et al. With bicuspid aortic valves. World Health. 2013;300(11):1317–1325. doi: 10.1001/jama.300.11.1317. [DOI] [PubMed] [Google Scholar]
- 2.Della Corte A, Bancone C, Dialetto G, et al. The ascending aorta with bicuspid aortic valve: a phenotypic classification with potential prognostic significance. Eur J Cardio-Thoracic Surg. 2014;46(2):240–247. doi: 10.1093/ejcts/ezt621. [DOI] [PubMed] [Google Scholar]
- 3.Verma S, Siu SC. Aortic dilatation in patients with bicuspid aortic valve. N Engl J Med. 2014;370(20):1920–1929. doi: 10.1056/NEJMra1207059. [DOI] [PubMed] [Google Scholar]
- 4.Elefteriades JA, Farkas EA. Thoracic aortic aneurysm. Clinically pertinent controversies and uncertainties. J Am Coll Cardiol. 2010;55(9):841–857. doi: 10.1016/j.jacc.2009.08.084. [DOI] [PubMed] [Google Scholar]
- 5.Pape LA, Tsai TT, Isselbacher EM, et al. Aortic diameter > 5.5 cm is not a good predictor of type a aortic dissection observations from the International Registry of Acute Aortic Dissection (IRAD) Circulation. 2007;116:1120–1127. doi: 10.1161/CIRCULATIONAHA.107.702720. [DOI] [PubMed] [Google Scholar]
- 6.Michelena HI, Khanna AD, Mahoney D, et al. Incidence of aortic complications in patients with bicuspid aortic valves. JAMA. 2011;306(10):1104–1112. doi: 10.1001/jama.2011.1286. [DOI] [PubMed] [Google Scholar]
- 7.Mahadevia R, Barker AJ, Schnell S, et al. Bicuspid aortic cusp fusion morphology alters aortic three-dimensional outflow patterns, wall shear stress, and expression of aortopathy. Circulation. 2014;129(6):673–682. doi: 10.1161/CIRCULATIONAHA.113.003026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Guzzardi DG, Barker AJ, Van Ooij P, et al. Valve-related hemodynamics mediate human bicuspid aortopathy: insights from wall shear stress mapping. J Am Coll Cardiol. 2015;66(8):892–900. doi: 10.1016/j.jacc.2015.06.1310. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Girdauskas E, Borger MA, Secknus M-A, Girdauskas G, Kuntze T. Is aortopathy in bicuspid aortic valve disease a congenital defect or a result of abnormal hemodynamics? A critical reappraisal of a one-sided argument. Eur J Cardio-Thoracic Surg. 2011;39(6):809–814. doi: 10.1016/j.ejcts.2011.01.001. [DOI] [PubMed] [Google Scholar]
- 10.Hope MD, Hope TA, Meadows AK, et al. Bicuspid aortic valve : four-dimensional MR evaluation of ascending aortic systolic methods : results. Radiology. 2010;255(1):53–61. doi: 10.1148/radiol.09091437. [DOI] [PubMed] [Google Scholar]
- 11.Bissell MM, Hess AT, Biasiolli L, et al. Aortic dilation in bicuspid aortic valve disease: flow pattern is a major contributor and differs with valve fusion type. Circ Cardiovasc Imaging. 2013;6(4):499–507. doi: 10.1161/CIRCIMAGING.113.000528. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Bieging ET, Frydrychowicz A, Wentland AL, et al. In vivo three-dimensional mr wall shear stress estimation in ascending aortic dilatation. J Magn Reson Imaging. 2011;33(3):589–597. doi: 10.1002/jmri.22485. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Meierhofer C, Schneider EP, Lyko C, et al. Wall shear stress and flow patterns in the ascending aorta in patients with bicuspid aortic valves differ significantly from tricuspid aortic valves: a prospective study. Eur Heart J Cardiovasc Imaging. 2013;14:797–804. doi: 10.1093/ehjci/jes273. [DOI] [PubMed] [Google Scholar]
- 14.Barker AJ, Markl M, Bürk J, et al. Bicuspid aortic valve is associated with altered wall shear stress in the ascending aorta. Circ Cardiovasc Imaging. 2012;5(4):457–466. doi: 10.1161/CIRCIMAGING.112.973370. [DOI] [PubMed] [Google Scholar]
- 15.Malek AM, Alper SL, Izumo S. Hemodynamic shear stress and its role in atherosclerosis. JAMA. 1999;282(21):2035–2042. doi: 10.1001/jama.282.21.2035. [DOI] [PubMed] [Google Scholar]
- 16.Ruddy JM, Jones JA, Stroud RE, Mukherjee R, Spinale FG, Ikonomidis JS. Differential effect of wall tension on matrix metalloproteinase promoter activation in the thoracic aorta. J Surg Res. 2010;160(2):333–339. doi: 10.1016/j.jss.2008.12.033. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.van Ooij P, Potters WV, Collins J, et al. Characterization of abnormal wall shear stress using 4D flow MRI in human bicuspid aortopathy. Ann Biomed Eng. 2015;43(6):1385–1397. doi: 10.1007/s10439-014-1092-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Gu T, Korosec FR, Block WF, et al. PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography. AJNR Am J Neuroradiol. 2005;26(4):743–749. [PMC free article] [PubMed] [Google Scholar]
- 19.Johnson KM, Markl M. Improved SNR in phase contrast velocimetry with five-point balanced flow encoding. Magn Reson Med. 2010;63:349–355. doi: 10.1002/mrm.22202. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Johnson KM, Lum DP, Turski PA, Block WF, Mistretta CA, Wieben O. Improved 3D phase contrast MRI with off-resonance corrected dual Echo VIPR. Magn Reson Med. 2009;60(6):1329–1336. doi: 10.1002/mrm.21763. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Markl M, Frydrychowicz A, Kozerke S, Hope MD, Wieben O. 4D flow MRI. J Magn Reson Imaging. 2012;36(5):1015–1036. doi: 10.1002/jmri.23632. [DOI] [PubMed] [Google Scholar]
- 22.Sigovan M, Hope MD, Dyverfeldt P, Saloner D. Comparison of four-dimensional flow parameters for quantification of flow eccentricity in the ascending aorta. J Magn Reson Imaging. 2011;34(5):1226–1230. doi: 10.1002/jmri.22800. [DOI] [PubMed] [Google Scholar]
- 23.Hess AT, Bissell MM, Glaze SJ, et al. Evaluation of circulation, Γ, as a quantifying metric in 4D flow MRI. J Cardiovasc Magn Reson. 2013;15(Suppl 1):E36. doi: 10.1186/1532-429X-15-S1-E36. [DOI] [Google Scholar]
- 24.Bensalah MZ, Bollache E, Kachenoura N, et al. Geometry is a major determinant of flow reversal in proximal aorta. Am J Physiol Heart Circ Physiol. 2014;306:1408–1416. doi: 10.1152/ajpheart.00647.2013. [DOI] [PubMed] [Google Scholar]
- 25.Stalder AF, Russe MF, Frydrychowicz A, Bock J, Hennig J, Markl M. Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Magn Reson Med. 2008;60(5):1218–1231. doi: 10.1002/mrm.21778. [DOI] [PubMed] [Google Scholar]
- 26.Campens L, Demulier L, De Groote K, et al. Reference values for echocardiographic assessment of the diameter of the aortic root and ascending aorta spanning all age categories. Am J Cardiol. 2014;114(6):914–920. doi: 10.1016/j.amjcard.2014.06.024. [DOI] [PubMed] [Google Scholar]
- 27.Whittaker J, Somers M, Whitehead C. The netlog transformation and quantile regression for the analysis of a large credit scoring database. Journal R Stat Soc Ser C. 2005;54(5):863–878. doi: 10.1111/j.1467-9876.2005.00520.x. [DOI] [Google Scholar]
- 28.Evangelista A, Gallego P, Calvo-Iglesias F, et al. Anatomical and clinical predictors of valve dysfunction and aortic dilation in bicuspid aortic valve disease. Heart. 2017; 10.1136/heartjnl-2017-311560. [DOI] [PubMed]
- 29.Bürk J, Blanke P, Stankovic Z, et al. Evaluation of 3D blood flow patterns and wall shear stress in the normal and dilated thoracic aorta using flow-sensitive 4D CMR. J Cardiovasc Magn Reson. 2012;14(1):84. doi: 10.1186/1532-429X-14-84. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Lorenz R, Bock J, Barker AJ, et al. 4D flow magnetic resonance imaging in bicuspid aortic valve disease demonstrates altered distribution of aortic blood flow helicity. Magn Reson Med. 2014;71(4):1542–1553. doi: 10.1002/mrm.24802. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Hope MD, Hope TA, Crook SES, et al. 4D flow CMR in assessment of valve-related ascending aortic disease. JACC Cardiovasc Imaging. 2011;4(7):781–787. doi: 10.1016/j.jcmg.2011.05.004. [DOI] [PubMed] [Google Scholar]
- 32.Barker AJ, Lanning C, Shandas R. Quantification of hemodynamic wall shear stress in patients with bicuspid aortic valve using phase-contrast MRI. Ann Biomed Eng. 2010;38(3):788–800. doi: 10.1007/s10439-009-9854-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Hope TA, Markl M, Wigström L, Alley MT, Miller DC, Herfkens RJ. Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging. 2007;26(6):1471–1479. doi: 10.1002/jmri.21082. [DOI] [PubMed] [Google Scholar]
- 34.Dyverfeldt P, Bissell MM, Barker AJ, et al. 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson. 2015;17(1):72. doi: 10.1186/s12968-015-0174-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Cibis M, Potters WV, Gijsen FJ, et al. The effect of spatial and temporal resolution of cine phase contrast MRI on wall shear stress and oscillatory shear index assessment. PLoS One. 2016;11(9):1–15. doi: 10.1371/journal.pone.0163316. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Markl M, Wallis W, Harloff A. Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI. J Magn Reson Imaging. 2011;33(4):988–994. doi: 10.1002/jmri.22519. [DOI] [PubMed] [Google Scholar]
- 37.Sotelo J, Urbina J, Valverde I, et al. 3D quantification of wall shear stress and oscillatory shear index using a finite-element method in 3D CINE PC-MRI data of the thoracic aorta. IEEE Trans Med Imaging. 2016;48(10):1–1. doi: 10.1109/TMI.2016.2517406. [DOI] [PubMed] [Google Scholar]
- 38.Van Ooij P, Powell AL, Potters WV, Carr JC, Markl M, Barker AJ. Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta. J Magn Reson Imaging. 2016;43(1):236–248. doi: 10.1002/jmri.24959. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The datasets generated and analyzed during the current study are available from the corresponding author on reasonable request.