Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2018 May 1.
Published in final edited form as: Ann Allergy Asthma Immunol. 2016 Nov 7;118(1):108–109. doi: 10.1016/j.anai.2016.10.001

Comparison of allergens collected from furnace filters and vacuum floor dust

Ryan Allenbrand 1, Charles S Barnes 1, Mubeen Mohammed 1, Luke Gard 1, Freddy Pacheco 1, Kevin Kennedy 1, Anita DiDonna 1, Jay Portnoy 1, Chitra Dinakar 1
PMCID: PMC5929112  NIHMSID: NIHMS961520  PMID: 27839669

The ideal determinant of allergen exposure would be knowing the specific types and amounts of allergen material deposited in the airways during any period.1 Because this is impractical, proxies for exposure determination have been used. In homes with forced-air heating ventilation and air conditioning, all air is passed through the system approximately once every hour.2 The filter in that system should collect a representative sample of airborne allergens. We previously reported that dust from high-efficiency furnace filters (FFs) contains substantial amounts of aeroallergen.3 In the present report, we describe the relation of FF allergens to allergen levels obtained from floor dust. We hypothesized that measuring allergens in FFs would provide a different assessment of exposure than floor or bedroom dust collection.

FQT12 1-inch disposable FFs were provided by Allergy Zone (Louisville, Kentucky). Antibodies and immunoassay standards were obtained from Indoor Biotechnologies (Chantilly, Virginia) and Greer Laboratories (Lenoir, North Carolina). Assays followed protocols described previously.3,4 Human subject aspects were approved by the institutional review board of the Children’s Mercy Hospital (Kansas City, Missouri). The collection of dust from FFs, HEPA vacuums (HVs), and children’s bedroom floors (CRs) has been described previously.3,5 Briefly, dust was removed from the HV or vacuumed from the CR or the FF using a HEPA unit with an x-cell-100 filter (Midwest Filtration, Cincinnati, Ohio). Levels of Der f 1 and Der p 1 are presented as the sum of dust mite allergens. Results are displayed as nanograms per gram of dust. Descriptive and comparative statistics were generated using SPSS software (IBM Corporation. Armonk, New York). Correlation coefficients were by the Spearman rank correlation equation performed in SPSS.

Demographics for homes in this study have been previously reported.3,5 All had forced-air heating ventilation and air conditioning systems. For this dataset, 54 homes were included in the FF data; 47 of those homes also had determination of allergen levels in dust taken from the HV, and 35 homes had allergen data from all 3 types of dust collected. Reasons for missing data points varied from insufficient quantity of dust collected to hurried appointments because of occupant requirements.

Statistical parameters are listed in Table 1. Few determinations were below the detection limit. Fel d 1 levels varied from 7,407 ng/g in FF dust to 635 ng/g in CR dust. Dust mite allergen was greatest in CR dust at 937 ng/g and lowest in FF dust at 240 ng/g. All fungal antigens were higher in FF dust, with Cladosporium species (42,342 ng/g) and Aspergillus species (34,011 ng/g) more than double the amount measured in HV and CR dust. Fungal allergen levels were detected less frequently in CR dust, with detection of Alternaria species in only 45% of homes.

Table 1.

Means, SDs, Medians, and Percentages of Homes Where the Allergen Was Detected Above the Lower Level of Detection and Correlations for Allergens in Furnace Filter Dust, Home Vacuum Dust, and Child’s Bedroom Floor Dust

Average SD Median Det % Corr w/FF Corr w/HV Corr w/CR
Allergen in furnace filter dust (ng/g)
Alternaria sp 8,275 4,945 8,356 91 1.00 0.06 0.22
Aspergillus sp 34,011 34,349 12,545 93 1.00 0.39b 0.62b
 Cat (Fel d 1) 7,407 18,918 843 100 1.00 0.37a 0.28
Cladosporium sp 42,342 25,960 35,504 98 1.00 0.10 0.01
 Dog (Can f 1) 622 798 180 96 1.00 0.44b 0.69b
 Dust mite (Der f 1 + Der p 1) 240 751 63 100 1.00 0.10 0.38a
Penicillium sp 12,248 9,233 10,148 94 1.00 0.10 −0.04
 Roach (Bla g 2) 690 2,734 99 96 1.00 0.08 0.06
 Mouse (Mus m 1) 343 457 179 98 1.00 0.62b 0.55b
Allergen in home HEPA vacuum dust (ng/g)
Alternaria sp 5,469 6,296 3,840 72 0.06 1.00 0.19
Aspergillus sp 16,527 32,871 4,420 72 0.39b 1.00 0.43b
 Cat (Fel d 1) 784 2,553 70 91 0.37a 1.00 0.54b
Cladosporium sp 15,546 17,911 10,930 81 0.10 1.00 0.50b
 Dog (Can f 1) 1,478 3,024 310 98 0.44b 1.00 0.42a
 Dust mite (Der f 1 + Der p 1) 625 862 210 100 0.10 1.00 0.41a
Penicillium sp 10,476 17,111 6,480 83 0.10 1.00 0.59b
 Roach (Bla g 2) 623 2,213 80 94 0.08 1.00 0.52b
 Mouse (Mus m 1) 387 580 140 100 0.62b 1.00 0.62b
Allergen in child’s bedroom floor dust (ng/g)
Alternaria sp 2,563 3,468 100 45 0.22 0.19 1.00
Aspergillus sp 7,927 18,769 1,425 61 0.62b 0.43b 1.00
 Cat (Fel d 1) 635 1,707 120 95 0.28 0.54b 1.00
Cladosporium sp 7,668 13,565 3,585 74 0.01 0.50b 1.00
 Dog (Can f 1) 1,348 3,097 300 100 0.69b 0.42a 1.00
 Dust mite (Der f 1 + Der p 1) 937 1,629 305 100 0.38a 0.41a 1.00
Penicillium sp 5,074 8,557 1,790 68 −0.04 0.59b 1.00
 Roach (Bla g 2) 305 597 110 89 0.06 0.52b 1.00
 Mouse (Mus m 1) 361 585 130 95 0.55b 0.62b 1.00

Abbreviations: Corr w/CR, correlation for allergens in child’s bedroom floor dust; Corr w/FF, correlation for allergens in furnace filter dust; Corr w/HV, correlation for allergens in home vacuum dust; Det %, percentage of homes where the allergen was detected above the lower level of detection.

a

Correlation is significant at the 0.05 level (2-tailed).

b

Correlation is significant at the 0.01 level (2-tailed).

Correlations for the 9 measured species in FF, HV, and CR dust ranged from fair (eg, 0.39 and 0.62 between Aspergillus allergen in the FF dust and the 2 reservoir collections) to poor (eg, 0.06 and 0.08 between roach allergen levels in the FF dust and reservoir collection). The most positive and significant correlations between FF and CR dust collections were for Aspergillus, cat, dog, and mouse allergens (typically significant at the .01 level).

We found that allergens in FF dust were a function of those present in settled dust for important allergen sources. Nonetheless, settled dust and dust from FF each provide unique information concerning exposure. Our results confirm previous observations concerning the nature of aeroallergens.6 Dust mite and cockroach allergens, previously reported to be associated with large particles,6,7 did not correlate well between FF dust and floor dust. In contrast, dog, cat, mouse, and Aspergillus allergens, previously reported to be associated with small particles,8,9 were much better correlated between FF dust and floor dust. Dust mite allergen concentration in FF dust was less than half the value of that allergen in HV dust or CR dust. The observation that dust mite allergen quickly precipitates from the air has been previously documented.9

Spearman correlation analysis (Table 1) indicated good correlation between FF dust allergen levels and the 2 settled dust collections for the same house. Correlations were especially good for Aspergillus species, Fel d 1, Can f 1, and Mus m 1. Unexpectedly, correlations were not high for 3 of the 4 fungal genera. The 4 allergenic materials with significant positive correlations are believed to be unique to indoor air and would be expected to correlate with settled dust collections even if they were present in the settled dust at lower levels than in the FF dust. The relations of the 2 settled dust collections has been reported previously.5

The study has limitations especially in generalizability to other types of housing. Houses were typical to the Midwestern United States. Housing in other areas of the United States might not have the same types of heating and cooling systems. Houses were measured during heating and cooling seasons and we did not have the ability to control how often the heating ventilation and air conditioning fan was operated. All measurements were normalized to gram of dust, not cubic meter of air. Also, different vacuum systems yield different collections.10

We found that aeroallergen components filtered from air in Midwestern homes correlate with, but are not identical to, aeroallergen components found in HV dust from those homes. Specific allergens expected to remain airborne for long periods tended to occur at a higher concentration in FF dust. Conversely, those aeroallergens not expected to remain airborne tended to occur at a lower concentration. The measurement of aeroallergens from FFs represents another avenue for evaluating the overall aeroallergen exposure of allergic individuals. The variability in results based on measurement technique suggests that allergen measurement can be of value in research settings and potentially in selected circumstances where antigen detection is prospectively defined to have potentially important management implications. Caution needs to be exercised when recommending widespread home allergen measurement, including the use of potentially costly health care resources for allergen quantitation, until the clinical value of the results is demonstrated.

Acknowledgments

Funding Sources: The Kansas City Safe & Healthy Home Partnership (grant MOLHH0159-07) awarded to Children’s Mercy Hospital by the US Department of Housing and Urban Development (2008–2012), the Central Plains Center for American Indian Health Disparities (National Institutes of Health grant P20 MD004805), the US Department of Housing and Urban Development (grant MOLHH0159-07), and a HUD Healthy Homes Technical Studies Grant (Funding Opportunity FR-5700-N-12).

Footnotes

Disclosures: Charles S. Barnes serves as a consultant for Clorox Corporation and is funded by research grants from the US Department of Housing and Urban Development. The remaining authors have no conflicts of interest.

References

  • 1.Zartarian VG, Ott WR, Duan N. A quantitative definition of exposure and related concepts. J Expo Anal Environ Epidemiol. 1997;7:411–437. [PubMed] [Google Scholar]
  • 2.ANSI/ASHRAE. ANSI/ASHRAE Standard 62.1-2013, Ventilation for Acceptable Indoor Air Quality. Supplement. Atlanta, GA: ASHRAE Manager of Publications; 2015. [Google Scholar]
  • 3.Barnes CS, Allenbrand R, Mohammed M, et al. Measurement of aeroallergens from furnace filters. Ann Allergy Asthma Immunol. 2015;114:221–225. doi: 10.1016/j.anai.2014.10.015. [DOI] [PubMed] [Google Scholar]
  • 4.Barnes CS, Kennedy K, Johnson L, et al. Use of dilute sodium hypochlorite spray and home cleaning to reduce indoor allergen levels and improve asthma health parameters. Ann Allergy Asthma Immunol. 2008;101:551–552. doi: 10.1016/S1081-1206(10)60297-9. [DOI] [PubMed] [Google Scholar]
  • 5.Barnes C, Portnoy JM, Ciaccio CE, Pacheco F. A comparison of subject room dust with home vacuum dust for evaluation of dust-borne aeroallergens. Ann Allergy Asthma Immunol. 2013;110:375–379. doi: 10.1016/j.anai.2013.02.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Custis NJ, Woodfolk JA, Vaughan JW, Platts-Mills TA. Quantitative measurement of airborne allergens from dust mites, dogs, and cats using an ion-charging device. Clin Exp Allergy. 2003;33:986–991. doi: 10.1046/j.1365-2222.2003.01706.x. [DOI] [PubMed] [Google Scholar]
  • 7.De Lucca SD, Taylor DJ, O’Meara TJ, Jones AS, Tovey ER. Measurement and characterization of cockroach allergens detected during normal domestic activity. J Allergy Clin Immunol. 1999;104:672–680. doi: 10.1016/s0091-6749(99)70341-6. [DOI] [PubMed] [Google Scholar]
  • 8.Ohman JL, Jr, Hagberg K, MacDonald MR, Jones RR, Jr, Paigen BJ, Kacergis JB. Distribution of airborne mouse allergen in a major mouse breeding facility. J Allergy Clin Immunol. 1994;94:810–817. doi: 10.1016/0091-6749(94)90147-3. [DOI] [PubMed] [Google Scholar]
  • 9.Tovey ER, Chapman MD, Wells CW, Platts-Mills TA. The distribution of dust mite allergen in the houses of patients with asthma. Am Rev Respir Dis. 1981;124:630–635. doi: 10.1164/arrd.1981.124.5.630. [DOI] [PubMed] [Google Scholar]
  • 10.Sandel M, Murphy JS, Dixon SL, et al. A side-by-side comparison of three allergen sampling methods in settled house dust. J Expo Sci Environ Epidemiol. 2014;24:650–656. doi: 10.1038/jes.2014.30. [DOI] [PubMed] [Google Scholar]

RESOURCES