Abstract
We investigate numerically the microscale blood flow in which red blood cells (RBCs) are partially infected by Plasmodium falciparum, the malaria parasite. The infected RBCs are modeled as more rigid cells with less deformability than healthy ones. Our study illustrates that, in a 10 μm microvessel in low-hematocrit conditions (18% and 27%), the Plasmodium falciparum-infected red blood cells (Pf-IRBCs) and healthy ones first form a train of cells. Because of the slow moving of the Pf-IRBCs, the local hematocrit (Hct) near the Pf-IRBCs is then increased, to approximately 40% or even higher values. This increase of the local hematocrit is temporary and is kept for a longer length of time because of the long RBC train formed in 27%-Hct condition. Similar hematocrit elevation at the downstream region with 45%-Hct in the same 10 μm microvessel is also observed with the cells randomly located. In 20 μm microvessels with 45%-Hct, the Pf-IRBCs slow down the velocity of the healthy red blood cells (HRBCs) around them and then locally elevate the volume fraction and result in the accumulation of the RBCs at the center of the vessels, thus leaving a thicker cell free layer (CFL) near the vessel wall than normal. Variation of wall shear stress (WSS) is caused by the fluctuation of local Hct and the distance between the wall and the RBCs. Moreover, in high-hematocrit condition (45%), malaria-infected cells have a tendency to migrate to the edge of the aggregates which is due to the uninterrupted hydrodynamic interaction between the HRBCs and Pf-IRBC. Our results suggest that the existence of Pf-IRBCs is a nonnegligible factor for the fluctuation of hematocrit and WSS and also contributes to the increase of CFL of pathological blood flow in microvessels. The numerical approach presented has the potential to be utilized to RBC disorders and other hematologic diseases.
1. Introduction
Every year, millions of people worldwide are infected with malaria, a mosquito-borne infectious disease. It is estimated that the resulting deaths are 731,000 in 2015 alone. Although the rates of disease have decreased in recent years, there is still a long way to go before it is virtually eliminated. When infected by malaria, Plasmodium falciparum, the parasite, invades and develops inside the human red blood cells (RBCs) and makes them stiffer than heathy cells [1–3]. Experimental study in which the deformability was assessed by measuring the pressure and time required for cell entry into 3 μm pipettes has shown that the deformability decreases approximately 20-fold as rings mature to the schizont stage [4]. This change of deformability of healthy red blood cells (HRBCs) is due to the alternation of the cell membrane and cytoskeleton by the parasite [5, 6]. The modified blood rheology, raised flow resistance, and vasoocclusion may be the direct effect of this change in biomechanical property of infected RBCs [7, 8]. Thus, a realistic model for malaria-infected blood flow has to incorporate cell membrane stiffening [3, 9–11].
Under physiological conditions, HRBCs undergo lateral migration and thus form a dense red blood cell region near the center and create a cell free layer (CFL) close to the blood vessel wall [12]. When Plasmodium falciparum-infected red blood cells (Pf-IRBCs) are presented together with HRBCs, they are apt to move away from the vessel center and this phenomenon is called margination. Margination effect was first reported for leukocytes in blood flow [13]. This interesting aspect of the parasite-infected RBCs in malaria has been investigated experimentally [14, 15] and numerically [16]. Moreover, the Pf-IRBCs may adhere to microvasculature in postcapillary venules and arterioles [14, 17].
Microfluidic devices provide promising opportunities for the monitoring of the behavior of Pf-IRBCs in microflow [8, 18, 19]. In [18], a microfluidic apparatus with a row of triangular barriers was fabricated and the traversal of Pf-IRBCs was considered by the experimental and simulation study in fluid flow. It was observed that Pf-IRBCs traveled on average slower than HRBCs due to raised viscosity and membrane stiffness. In addition, microfluidic devices have been utilized in manipulating RBCs in other blood diseases, such as sickle-cell disease [20]. Although it is difficult to catch the cell-cell interactions using current experimental methods due to the complexity of the cell membrane, directly observing and quantifying the interactions of blood cells in microchannels have been conducted by in vitro investigations [21–24]. In these studies, effect of hematocrit and geometry [21] as well as temperature [24] on RBC radial dispersion in microchannels has been studied and quantified. Interaction between two RBCs [22] and the iteration of fluid particles with RBCs can also be identified [23].
One of the advantages of numerical models is their predictive capability and they can be applied to a number of diseases related to blood flow (such as malaria [3, 9, 10, 25, 26] and sickle-cell disease [27–30]). Numerical study [16] explained the mechanism of the margination effect of Pf-IRBCs and predicted that it might enhance cytoadhesion. Factors that affect the margination process have also been studied numerically [31]. Numerical methods have also been used to quantitatively predict the flow resistance through relative apparent viscosity in microvessels [9].
In the present study, a numerical model of microscale blood flow with malaria infection has been developed. We investigated the hydrodynamic interaction between Pf-IRBC and HRBCs in two-dimensional channels under different hematocrit (Hct) conditions. We adopted two-dimensional scheme because we believe that two-dimensional simulations are still helpful as a tool for preliminary research to aid conceptual understanding of microscale blood flow, especially for large systems where three-dimensional simulations are extremely costly. It can qualitatively capture the behavior of RBCs and may provide a guidance for future research. The numerical technique is in general able to be employed to those diseases and abnormalities where mechanical characteristics of cells have been altered.
2. Mathematical Models and Numerical Methods
The particulars of the red blood cell model in the present study were previously reported in [32, 33], and only a short interpretation is offered here. Presuming that cytoplasm of the red blood cells and blood plasma are Newtonian and incompressible fluids. The equations governing the blood flow in a rectangle domain Ωf are given by
| (1) |
| (2) |
where the notation t is for time, ρ for density, u for velocity, p for pressure, μ for dynamic viscosity, and f for external force. No-slip boundary condition is enforced at the channel walls. In the direction of flow, periodic boundary condition is applied. The solution method of (1) and (2) has been thoroughly described elsewhere [34], where a uniform finite element triangulation (Figure 1) has been utilized. A RBC's membrane is simulated using a spring model. In the instance of a Pf-IRBC, a stiff cell is represented through increasing the membrane constants of the RBC model. This model was confirmed in the previous study to well simulate the deformation of RBCs in shear and Poiseuille flow [32]. The coupling of the deformable RBCs with fluid flow is achieved utilizing the immersed boundary method (IBM). The spring model for the RBCs and the immersed boundary method are reviewed briefly for completeness.
Figure 1.

Schematic representation of the triangular mesh used in the simulations.
2.1. Red Blood Cell Model
The RBC membrane is simulated by N vertices that are joined through springs, where each vertex is depicted using a membrane particle. The model takes into consideration the elasticity and bending modulus, as well as constraints of enclosed area as follows:
| (3) |
where
| (4) |
is the elastic energy and the bending energy is modeled by
| (5) |
In (4) and (5), N denotes number of springs; kl and kb denote spring moduli due to changes in length and bending angle between two adjacent springs, respectively; li is the time-dependent length of the ith spring element and l0 is its reference length; and θi is the angle that is formed by two adjoined springs at the ith particle. In addition, by taking into consideration the area conservation constraint, the penalty function is given as [35]
| (6) |
with se and s being the equilibrium area and the time-dependent area of the RBC, respectively. Details of applying this spring model to obtain the shape of the RBCs can be found elsewhere [32, 33].
2.2. The Immersed Boundary Method
The cell-plasma interaction was coped with by the immersed boundary method (IBM) [36], in which the deformable object's boundary is estimated as follows: firstly, the force term at the membrane node X = {X1, X2} influences the nearby fluid nodes denoted by x = {x1, x2} through a discrete delta function δ:
| (7) |
where h denotes the mesh size and
| (8) |
The discrete delta function δ is
| (9) |
The force in (7) is coupled in (1); next, the membrane velocity is influenced by the adjacent fluid field using the same delta function:
| (10) |
Lastly, the location of the membrane is renewed by
| (11) |
3. Problem Description
In this paper, flows were simulated in a rectangular channel with a height of 10 μm and 20 μm in y-direction. The horizontal width of the channel was specified at 30 μm for the simulations, but the periodic boundary condition was engaged to detect RBCs' long-term behavior in flow. The flow was pushed by a pressure gradient between the inlet and outlet. In the computational domain (10 μm × 30 μm), we included a Pf-IRBC and some HRBCs. The healthy RBCs had membrane constants kb = kl = 1.0 × 10−12 Nm, and the Pf-IRBC was characterized as 20-fold membrane stiffness [4]. To examine the influences of Hct on the Pf-IRBC, we studied the flow for three different hematocrit values in this 10 μm channel, Hct = 18%, Hct = 27%, and Hct = 45%, and also a single Pf-IRBC without HRBCs. The number ratio of the Pf-IRBC to HRBCs for the three cases was then 1 : 3, 1 : 5, and 1 : 9, respectively. In the computational domain (20 μm × 30 μm), we included several Pf-IRBCs and some HRBCs. We compared the flows of two cases in the 20 μm channel: Hct = 45%, and one Pf-IRBC; Hct = 45%, and two Pf-IRBCs. The number ratio of the Pf-IRBC to HRBCs was then 1 : 19 and 1 : 9, respectively. For clarity, the parameters that are adopted in the present investigation are listed in Table 1.
Table 1.
Parameters used for the simulations.
| Parameter | Symbol | Value |
|---|---|---|
| Blood plasma density | ρ | 1.0 g/cm3 |
| Blood plasma viscosity | μ | 1.2 cp |
| Axial pressure gradient in 10 μm channel | P x | 600 KPa/m |
| Axial pressure gradient in 20 μm channel | P x | 400 KPa/m |
| Radius of the circle in RBC model | r 0 | 2.8 μm |
| Number of springs in RBC model | N | 76 |
| Membrane mass in RBC model | m | 2.0 × 10−4 g |
| Membrane viscosity in RBC model | γ | 8.8 × 10−7 N·s/m |
| Spring constants for HRBC membrane | k l & kb | 1.0 × 10−12 Nm |
| Spring constants for Pf-IRBC membrane | k l & kb | 2.0 × 10−11 Nm |
| Width of the channel | L | 30 μm |
| Height of the channel | D | 10 μm, 20 μm |
| Mesh size | h | 1/80 μm |
| Time step | Δt | 1 × 10−5 ms |
4. Results
4.1. Mesh Independence Study
A mesh independence study has been conducted in the 10 μm by 30 μm channel by varying the mesh size h with a single HRBC and the results are shown in Figure 2. Three values of mesh size, that is, h = 1/40 μm, h = 1/80 μm, and h = 1/160 μm, were chosen and the trajectories of the cell center of the HRBC are plotted versus time. The other parameters were kept unchanged and the values used are presented in Table 1. The analysis shows that the HRBCs migrate to the centerline of the channel in the flow when they are located off the centerline initially and this result is independent of the mesh size employed in the simulations. Therefore a mesh size of h = 1/80 μm has been selected for all the simulations in this study.
Figure 2.

History of the cell center of a HRBC in the 10 μm channel at different mesh size h values.
4.2. Variation of Hematocrit and Wall Shear Stress (WSS)
Figure 3 displays the motion and blood flow behaviors in the 10 μm channel with Hct = 18% and the number ratio of Pf-IRBC to HRBC 1 : 3. Note the value of Hct is significantly lower and the number ratio of Pf-IRBC to HRBC is much higher than in a patient. The purpose of including this configuration is to remove the hematocrit effect but to study the hydrodynamic effect of a Pf-IRBC on other HRBCs. The Pf-IRBC is presented by the purple cell. The pressure field is also shown in the same plot. Because Hct is relatively low, the interaction between the HRBCs and Pf-IRBC is weak. The RBCs form a loose “train” formation so that the cell distribution is almost uniform. The Pf-IRBC deforms less than HRBCs and maintains its original biconcave shape while the HRBCs deform into various shapes, such as a parachute, slipper, or bullet. The Pf-IRBC and neighbor HRBC can touch and immediately separate; thus the interaction is not continuous.
Figure 3.
Successive snapshots of malaria-infected RBCs with Hct = 18% in the 10 μm channel. The purple cell represents the Pf-IRBC. The number ratio of Pf-IRBC to HRBC is 1 : 3. The time instants for simulation are (a) t = 5 ms, (b) t = 10 ms, (c) t = 20 ms, and (d) t = 25 ms. The pressure field is also illustrated.
It can also be observed from Figure 3 that the flow field around the cells is disturbed and this disturbance will introduce corresponding change in shear stress on the channel walls. Figure 4 demonstrates the wall shear stress (WSS) variation along the channel walls for the same simulation condition in Figure 3. An interesting peak-valley-peak structure of WSS has been observed. The valley regions on the WSS curve correspond to the RBC that is close to the vessel wall, while the peak regions correspond to the cell-cell gap.
Figure 4.
Wall shear stress variation along the channel walls for the simulation of malaria-infected RBCs with Hct = 18% in the 10 μm channel. The number ratio of Pf-IRBC to HRBC is 1 : 3. The time instants for simulation are (a) t = 5 ms, (b) t = 10 ms, (c) t = 20 ms, and (d) t = 25 ms (the time instants correspond to the same time instants in Figure 3).
When Hct is 27% as shown in Figure 5, a more compact train is observed and thus the Hct value at the train region can temporally increase to a higher value. It can be noticed from Figure 6 that the cell-wall gap size is the major factor influencing the WSS variation magnitude. Due to the narrow gap between the channel wall and cell membrane shown in Figure 5(d), the WSS variation in Figure 6(d) is most profound among all subfigures.
Figure 5.
Successive snapshots of malaria-infected RBCs with Hct = 27% in the 10 μm channel. The purple cell represents the Pf-IRBC. The number ratio of Pf-IRBC to HRBC is 1 : 5. The time instants for simulation are (a) t = 5 ms, (b) t = 10 ms, (c) t = 20 ms, and (d) t = 50 ms. The pressure field is also illustrated.
Figure 6.
Wall shear stress variation along the channel walls for the simulation of malaria-infected RBCs with Hct = 27% in the 10 μm channel. The number ratio of Pf-IRBC to HRBC is 1 : 5. The time instants for simulation are (a) t = 5 ms, (b) t = 10 ms, (c) t = 20 ms, and (d) t = 25 ms (the time instants correspond to the same time instants in Figure 5).
In contrast, the flow behavior of cells in Hct = 45% is different (Figure 7). We also observe Hct elevation at the downstream region in this high-Hct condition. The cells do not form a train but squeeze together with the cells being randomly located. This is for the reason that the HRBCs are frequently moving faster than the single Pf-IRBC and they are pushed by the following HBRCs to pass the Pf-IRBC in the gap between the cells and the wall. When this happens, the Pf-IRBC is forced to locate and flow near the vessel wall. The local Hct, which is defined as the hematocrit in a 10 μm length of the channel centered at the Pf-IRBC, can increase as well (Figure 7(c)), but however may not last very long. The corresponding WSS shown in Figure 8 for this case varies much more severely compared to the low-Hct cases.
Figure 7.
Successive snapshots of malaria-infected RBCs with Hct = 45% in the 10 μm channel. The purple cell represents the Pf-IRBC. The number ratio of Pf-IRBC to HRBC is 1 : 9. The time instants for simulation are (a) t = 5 ms, (b) t = 10 ms, (c) t = 15 ms, and (d) t = 20 ms. The pressure field is also illustrated.
Figure 8.
Wall shear stress variation along the channel walls for the simulation of malaria-infected RBCs with Hct = 45% in the 10 μm channel. The number ratio of Pf-IRBC to HRBC is 1 : 9. The time instants for simulation are (a) t = 5 ms, (b) t = 10 ms, (c) t = 20 ms, and (d) t = 25 ms (the time instants correspond to the same time instants in Figure 7).
Then we simulated blood flow with Hct = 45% and the number ratio of 1 : 19 and 1 : 9 in the 20 μm channel, and the results are presented in Figure 9 which illustrates typical cell distribution in this geometry. The HRBCs deform more than the Pf-IRBCs. The Pf-IRBCs move slower but however do not cause significant Hct fluctuation. It is also noted that the pressure field changes with the motion of the RBCs. The cell depletion region causes a low pressure zone, while the pressure is relatively higher for the cell accumulating region. This pressure difference is more obvious in Figures 5(d), 7(c), and 9(a). It is also worth noting that the WSS in the 20 μm channel experiences more profound variation (Figure 10).
Figure 9.
Typical configurations of RBCs with Hct = 45% in the 20 μm channel: (a) time instant t = 20 ms; the number ratio of Pf-IRBC to HRBC is 1 : 19; (b) time instant t = 40 ms; the number ratio of Pf-IRBC to HRBC is 1 : 9. The purple cells represent the Pf-IRBCs. The pressure field is also illustrated.
Figure 10.
Wall shear stress variation along the channel walls for the simulation of malaria-infected RBCs with Hct = 45% in the 20 μm channel: (a) at time instant t = 20 ms; the number ratio of Pf-IRBC to HRBC is 1 : 19; (b) at time instant t = 40 ms; the number ratio of Pf-IRBC to HRBC is 1 : 9 (the time instants correspond to the same time instants in Figure 9).
Figure 11 shows instantaneous velocity of Pf-IRBC compared to those of HRBCs for a period of time in the 10 μm channel. In the blood with 18%-Hct, the Pf-IRBCs move much slower than HRBCs at the beginning of the simulation. Thus the HRBCs downstream and next to the Pf-IRBC (represented by the red line in Figure 11(a)) caught up with the Pf-IRBC and pushed it forward. The velocity of the Pf-IRBC then increases to almost the same as the downstream HRBC. Note that, in the 27%-Hct blood, all the HRBCs are affected by the Pf-IRBC and slow down at the beginning of the simulation. All the cells move at about the same velocity when the velocities of the infected cell and noninfected cells reach the same value. The situation in the 45%-Hct blood is quite different. Because of the compact configuration of the cells in the channel, although the velocity of the Pf-IRBC is smaller, the difference is not dramatic. The results further confirm that the Pf-IRBCs move slower than HRBCs in microscale blood flow and the Hct level plays an important role in it.
Figure 11.
Instantaneous velocity of Pf-IRBC and HRBCs for a period of time in the 10 μm channel with (a) Hct = 18%, (b) Hct = 27%, and (c) Hct = 45%.
To further quantify the effect of Pf-IRBCs on the variation of hematocrit, we examined the discharge hematocrit at the channel outlet. Discharge hematocrit Hd is the volume fraction of RBCs measured at the vessel exit and is defined in our simulations as follows:
| (12) |
where and denote the average cell speed and average flow speed, respectively. Figure 12 compares the instant Hd in simulations for a time period of 2 ms with different Hct values in the two microvessels. In general, the variation of Hd is more dramatic in the 10 μm channel than in the 20 μm channel. In the 10 μm channel for the 27%-Hct case, the discharge hematocrit is locally raised, to roughly 40% in the upstream zone of the Pf-IRBC. Such a high volume fraction of RBCs is caused by the turbulent flow owing to the slowly moving Pf-IRBC; thus, the discharge hematocrit turns substantially lower downstream, and it can sometimes be as low as ~0% in the cell void region. Similar variation of Hd for the 45%-Hct blood in the same channel is observed. However, because of the relatively high value of Hct, the highest and the lowest Hd recorded for the time period are ~60% and ~13%, respectively. On the other hand, in the 20 μm channel with 45%-Hct, the highest and the lowest Hd recorded for the time period are ~50% and ~22%, respectively. The number ratio of Pf-IRBC to HRBC seems to have no effect on the discharge hematocrit, although it does have an effect on the flow behavior.
Figure 12.
Variation of the discharge hematocrit for an arbitrary time period of 2 ms for the following: (a) Hct = 27% in the 10 μm channel; the number ratio of Pf-IRBC to HRBC is 1 : 5; (b) Hct = 45% in the 10 μm channel; the number ratio of Pf-IRBC to HRBC is 1 : 9; (c) Hct = 45% in the 20 μm channel; the number ratio of Pf-IRBC to HRBC is 1 : 19; (d) Hct = 45% in the 20 μm channel; the number ratio of Pf-IRBC to HRBC is 1 : 9.
4.3. Cell Free Layer (CFL) and Margination of Pf-IRBC
In Figure 13, trajectories of cell center are plotted for an arbitrary time period of 20 ms for the 10 μm and 20 μm channels with 45%-Hct. By taking into account the RBC's size, cell free layer in the 10 μm channel is about 1.5 μm. Cell free layer in this 20 μm channel is estimated as 1.9 μm which is 1 μm less than the averaged distance between the outmost cell center and the adjacent wall. Note that in Figure 13(c) the cell free layers at the top and the bottom wall seem to be slightly different. The reason for this difference is that the Pf-IRBCs are located close to the bottom wall, which causes the increase of the cell free layer. Therefore, the cell free layer thickness in Figure 13(c) is the averaged value at the top and the bottom wall. The results in the current study are bigger than the cell free layer thickness found by Maeda et al. [37] who reported cell free layers in the scope of 1–1.8 μm for blood vessel diameters 10–40 μm with Hct = 45%. The slight increase of the CFL in the 20 μm channel may be caused by the elevation of the local hematocrit: the RBC region is denser than normal thus generating a thicker CFL near the wall.
Figure 13.
Trajectories of cell center for an arbitrary time period of 20 ms for the following: (a) Hct = 45% in the 10 μm channel; the number ratio of Pf-IRBC to HRBC is 1 : 9; (b) Hct = 45% in the 20 μm channel; the number ratio of Pf-IRBC to HRBC is 1 : 19; (c) Hct = 45% in the 20 μm channel; the number ratio of Pf-IRBC to HRBC is 1 : 9.
Figures 14 and 15 show the trajectory of the radial location of the cell center of the Pf-IRBC in the 10 μm and 20 μm channels, respectively. The figures are illustrated for an arbitrary time duration of 20 ms for the non-single-cell cases. In the case of a single Pf-IRBC without HRBCs, it shifts to the center of the vessel gradually even when it is in the beginning settled close to the wall. The equilibrium position is not exactly at the centerline of the vessel due to its small degree of deformability.
Figure 14.

Time history of the radial location of the Pf-IRBC in the 10 μm channel for various simulation conditions. The radial location is defined as the distance between the center of the Pf-IRBC and the vessel center.
Figure 15.

Time history of the radial location of the Pf-IRBC in the 20 μm channel for various simulation conditions. The radial location is defined as the distance between the center of the Pf-IRBC and the vessel center.
Significant margination of Pf-IRBC is observed in the case of Hct = 45%, however not for the case of Hct = 18% and 27% in Figure 14. In the two latter cases, the Pf-IRBC can occasionally move toward the vessel wall because of the interaction of the next HRBC. However, this interaction did not last long because of the relatively low Hct value. Until the following HRBCs once again catch up to the Pf-IRBC, the Pf-IRBC moves almost along the channel center. Figure 7 displays the representative visualization of the distribution of RBCs for Hct = 45% in the 10 μm channel. The HRBCs can flow parallel to the axis of the channel and thus can pass the Pf-IRBC and push the Pf-IRBC away from the center. The Pf-IRBC can thus migrate to the vessel wall and flow close to the endothelial cells. When the surrounding HRBCs leave the Pf-IRBC, they return to the center of the channel promptly. On some occasions, the Pf-IRBC shifts back to the center of the channel. In this situation, the process will restart and the Pf-IRBC migrates to the wall once again.
Similar margination of Pf-IRBCs has been observed in the 20 μm channel (Figure 15). When there is only one Pf-IRBC and Hct is 45%, the Pf-IRBCs move toward the vessel wall and can reach the CFL occasionally. In the two Pf-IRBCs' case, it seems that the margination effect for one Pf-IRBC is more obvious than the other Pf-IRBC in the time period illustrated. As shown in Figure 9(b), HRBCs sometimes slip into the opening between channel wall and one Pf-IRBC and then push the Pf-IRBC away from the wall in this high-Hct condition. The Pf-IRBC may not have a chance to reach the CFL for a long time.
5. Discussion
Our simulation demonstrates that the Pf-IRBCs move slower than HRBCs and cause local Hct increase around the Pf-IRBC. The former effect is qualitatively in agreement with numerical results in [38]. The latter effect is severe in high-Hct conditions. In the 10 μm channel with 18% Hct (Figure 3), the volume fraction is sometimes elevated. However, this local increase of Hct cannot be maintained for long and the overall cell distribution is almost uniform. Although we can see the flow disturbance through the pressure field in this case, obviously this disturbance is not enough to maintain high-Hct region. On the other hand, in the same channel as Hct increases to 27% (Figure 5), the HRBCs and Pf-IRBC develop a train of cells. The Pf-IRBC and the following HRBC are close enough to have contact with each other and the HBCs are accumulated in the downstream region where the local Hct is elevated to around 40% (Figure 11(a)). In the 45% Hct condition (Figure 7), the train configuration is not demonstrated and the volume fraction is sometimes raised to about 50% or even 60% in the Pf-IRBC region. The volume fraction, however, immediately falls down since, in the upstream zone, the volume fraction is low, whereas, in the vessel of 20 μm, no significant local Hct increase has been seen in the simulations (Figure 9). Similar trends have been found for the discharge hematocrit values as well (Figure 12). However, we observe an increase of cell free layer thickness which means the RBCs are more tightly packed in the center region. This result is qualitatively consistent with in vitro findings [39]. Therefore, the slower moving of Pf-IRBC and its ability to block the HRBCs are the mechanism of local fluctuation of Hct. That is, a relatively high concentration of RBCs and narrow tube is necessary, to keep the contact of the HRBCs with the Pf-IRBC. Note that the present simulations do not incorporate the effects of adhesion interactions, which will give rise to a more severe and longer duration of aggregation of RBCs. Moreover, the pattern of WSS variation suggests that it could be the direct result of Hct and CFL variations.
Generally, HRBCs experience lateral migration because of their deformability and tend to accumulate at the center of the blood vessel therefore leaving a cell free layer close to the vessel wall (Figure 13). When the HRBCs are invaded by the Plasmodium falciparum parasite, they have been known to become less deformable. However, they still retain some deformability which makes them migrate to the centerline of the blood vessel in the single Pf-IRBC case (Figures 14 and 15). Margination of Pf-IRBC that occurred in our simulations especially in the high-Hct conditions suggests that the hydrodynamic interaction between the Pf-IRBC and HRBCs plays a key role. Although our simulations were conducted in 2D conditions, the results are qualitatively in agreement with experimental data by Hou et al. [15]. The quantitative discrepancy may be attributed to unlikely experimental circumstances such as the size of channel and Hct values. In [15], a 10 μm by 15 μm rectangular channel was used. They observed significant margination of Pf-IRBCs for blood sample with Hct = 40%. However, the margination effect was insignificant for blood sample of Hct = 10%. We have obtained the similar result that the RBCs in 18%-Hct blood show nearly uniform distributions. We illustrate that the Pf-IRBC can migrate and be away from the vessel wall in the 27%-Hct condition in the 10 μm channel. However, it migrates back to the channel center because of its deformability. This process of moving away and back to the center could happen repeatedly if the simulation time is sufficiently long. Moreover, they reported that some Pf-IRBCs still flowed close to the center in the high-Hct samples. We have observed a similar phenomenon in our simulations as shown in Figure 15. This is attributed to the continuous interaction between HRBCs and the Pf-IRBC because the Pf-IRBC is always surrounded by HRBCs. The HRBCs deform more and move faster than the Pf-IRBC. The HRBCs can slide into the gap between the Pf-IRBC and vessel wall and then push the Pf-IRBC away from the wall in high-Hct blood (Figure 9(b)). Thus, the Pf-IRBCs cannot be separated completely from HRBCs even in long enough channels. This result will help in designing and fabricating microfluidic devices.
Although we ignore the cytoadhesion of the Pf-IRBC to the endothelial cells in this study, this property has been reported experimentally and is believed to be a factor that enhances margination of Pf-IRBCs [40]. In their study, the effect of Hct on the adhesion and rolling to human dermal microvascular endothelial cells has been investigated in vitro. It has been found that both adhesion and rolling were intensified with raising Hct from 10% to 20%. They predicted that this enhancement was due to the rise in cell margination and contact period with endothelial cells. The results of Hct-dependent margination in the present study give support to their prediction. Pf-IRBCs will migrate to the vessel wall under a long contact period with HRBCs in high-Hct conditions in the 10 μm and the 20 μm vessels, whereas the margination is not obvious because of the occasional contacts in 18%-Hct sample.
6. Conclusions
This study illustrates the effects of Pf-IRBC on microscopic blood flow owing to hydrodynamic interaction between the HRBCs and Pf-IRBC. In the 10 μm vessel, HRBCs and a Pf-IRBC form a train of cells. Even in low-Hct conditions, HRBCs and a Pf-IRBC form a temporary train because the low volume concentration of RBCs does not submit continuous interaction. The local hematocrit is elevated to even above 50% around the Pf-IRBC in high-Hct conditions while Hct in other areas is deceased, resulting in local Hct fluctuation. Note that the cytoadhesion is not considered in this study; thus this aggregation of RBCs is mainly caused by the slow moving of Pf-IRBCs. The variation of WSS can be related to the fluctuation of Hct close to the wall and the distance between the wall and the nearest RBC. It is also observed that the Pf-IRBC tends to migrate to the vessel wall in high-Hct condition because of the continuous interaction between the Pf-IRBC and the HRBCs. The Pf-IRBC may migrate to the vessel wall and it can also move back to the channel center. We conclude that our results provide some insight into the hemodynamic influences of Pf-IRBCs in microvascular system and will help in improving microfluidic devices.
7. Limitations and Future Research
Firstly, we did not consider adhesive property of Pf-IRBCs, which is due to the formation of nanoscale knobs that protrude from the cell membrane within 24–48 hours of infection. Numerical study [38] on Pf-IRBCs with adhesive property has shown interesting phenomena including rolling motion on endothelial cells and complex interaction with HRBCs. It is reasonable to assume that when the cytoadherence of infected RBCs is included, the hemodynamics of blood flow will be significantly altered and the cytoadherence of Pf-IRBCs to endothelial cells will be incorporated in the future investigation.
Secondly, we described Pf-IRBCs as a hardened RBC characterized by a stiffer membrane which is a simple assumption. Imai et al. [25] modeled malaria parasite as a rigid core inside the Pf-IRBC. Zhang et al. [41] hypothesized that the nanoscale knobs that cause the stickiness of the cell membrane also cause the membrane to stiffen. Therefore modeling the cell membrane with multiple nanoscale knobs with mechanical property different from the elastic membrane will be a direction of our future research.
Finally, the current study used two-dimensional simulation scheme in a rectangular microchannel, which is a significant limitation in terms of direct interpretation of the computational results and comparison with clinic data because there is some discrepancy between our simulations and real-world system. For instance, the hematocrit and the flow rate are the major parameters that will be discrepant from the real values. For this reason, we only make qualitative comparison with experimental results in the paper. Realistic three-dimensional simulations with physiologically relevant hematocrit contents are needed in the future study to obtain more accurate results and to quantitatively compare with experimental data.
Acknowledgments
T. Wang acknowledges the support of the National Natural Science Foundation of China (Grant no. 11671203). Z. Xing was supported by the Ministry of Science and Technology of China (2017YFA0303200) and the State Key Program for Basic Researches of China (2014CB921103).
Conflicts of Interest
The authors declare that there are no conflicts of interest regarding the publication of this paper.
References
- 1.Cranston H. A., Boylan C. W., Carroll G. L., et al. Plasmodium falciparum maturation abolishes physiologic red cell deformability. Science. 1984;223(4634):400–403. doi: 10.1126/science.6362007. [DOI] [PubMed] [Google Scholar]
- 2.Diez-Silva M., Dao M., Han J., Lim C.-T., Suresh S. Shape and biomechanics characteristics of human red blood cells in health and disease. MRS Bulletin. 2010;35(5):382–388. doi: 10.1557/mrs2010.571. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Hosseini S. M., Feng J. J. How malaria parasites reduce the deformability of infected red blood cells. Biophysical Journal. 2012;103(1):1–10. doi: 10.1016/j.bpj.2012.05.026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Nash G. B., O'Brien E., Gordon-Smith E. C., Dormandy J. A. Abnormalities in the mechanical properties of red blood cells caused by Plasmodium falciparum. Blood. 1989;74(2):855–861. [PubMed] [Google Scholar]
- 5.Glenister F. K., Coppel R. L., Cowman A. F., Mohandas N., Cooke B. M. Contribution of parasite proteins to altered mechanical properties of malaria-infected red blood cells. Blood. 2002;99(3):1060–1063. doi: 10.1182/blood.V99.3.1060. [DOI] [PubMed] [Google Scholar]
- 6.Mills J. P., Diez-Silva M., Quinn D. J., et al. Effect of plasmodial RESA protein on deformability of human red blood cells harboring Plasmodium falciparum. Proceedings of the National Acadamy of Sciences of the United States of America. 2007;104(22):9213–9217. doi: 10.1073/pnas.0703433104. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.May H. O., White N. J. Molecular mechanisms of cytoadherence in malaria. American Journal of Physiology-Endocrinology and Metabolism. 1999;276(6):C1231–C1242. doi: 10.1152/ajpcell.1999.276.6.C1231. [DOI] [PubMed] [Google Scholar]
- 8.Shelby J. P., White J., Ganesan K., Rathod P. K., Chiu D. T. A microfluidic model for single-cell capillary obstruction by Plasmodium falciparum-infected erythrocytes. Proceedings of the National Acadamy of Sciences of the United States of America. 2003;100(25):14618–14622. doi: 10.1073/pnas.2433968100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Fedosov D. A., Lei H., Caswell B., Suresh S., Karniadakis G. E. Multiscale modeling of red blood cell mechanics and blood flow in malaria. PLoS Computational Biology. 2011;7(12):e1002270, 13. doi: 10.1371/journal.pcbi.1002270.e1002270 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Ye T., Phan-Thien N., Khoo B. C., Lim C. T. Stretching and relaxation of malaria-infected red blood cells. Biophysical Journal. 2013;105(5):1103–1109. doi: 10.1016/j.bpj.2013.07.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Wang T., Tao Y., Rongin U., Xing Z. A Two-Dimensional Numerical Investigation of Transport of Malaria-Infected Red Blood Cells in Stenotic Microchannels. BioMed Research International. 2016;2016 doi: 10.1155/2016/1801403.1801403 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Fedosov D. A., Caswell B., Popel A. S., Karniadakis G. E. M. Blood Flow and Cell-Free Layer in Microvessels. Microcirculation. 2010;17(8):615–628. doi: 10.1111/j.1549-8719.2010.00056.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Goldsmith H. L., Spain S. Margination of leukocytes in blood flow through small tubes. Microvascular Research. 1984;27(2):204–222. doi: 10.1016/0026-2862(84)90054-2. [DOI] [PubMed] [Google Scholar]
- 14.Ho M., Hickey M. J., Murray A. G., Andonegui G., Kubes P. Visualization of Plasmodium falciparum - Endothelium interactions in human microvasculature: Mimicry of leukocyte recruitment. The Journal of Experimental Medicine. 2000;192(8):1205–1211. doi: 10.1084/jem.192.8.1205. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Hou H. W., Bhagat A. A. S., Lin Chong A. G., et al. Deformability based cell margination - A simple microfluidic design for malaria-infected erythrocyte separation. Lab on a Chip . 2010;10(19):2605–2613. doi: 10.1039/c003873c. [DOI] [PubMed] [Google Scholar]
- 16.Imai Y., Nakaaki K., Kondo H., Ishikawa T., Teck Lim C., Yamaguchi T. Margination of red blood cells infected by Plasmodium falciparum in a microvessel. Journal of Biomechanics. 2011;44(8):1553–1558. doi: 10.1016/j.jbiomech.2011.02.084. [DOI] [PubMed] [Google Scholar]
- 17.Cooke B., Coppel R., Wahlgren M. Falciparum malaria: sticking up, standing out and out-standing. Parasitology Today. 2000;16(10):416–420. doi: 10.1016/s0169-4758(00)01753-1. [DOI] [PubMed] [Google Scholar]
- 18.Bow H., Pivkin I. V., Diez-Silva M., et al. A microfabricated deformability-based flow cytometer with application to malaria. Lab on a Chip . 2011;11(6):1065–1073. doi: 10.1039/c0lc00472c. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Wu T., Feng J. J. Simulation of malaria-infected red blood cells in microfluidic channels: passage and blockage. Biomicrofluidics. 2013;7(4) doi: 10.1063/1.4817959.044115 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Higgins J. M., Eddington D. T., Bhatia S. N., Mahadevan L. Sickle cell vasoocclusion and rescue in a microfluidic device. Proceedings of the National Acadamy of Sciences of the United States of America. 2007;104(51):20496–20500. doi: 10.1073/pnas.0707122105. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Lima R., Ishikawa T., Imai Y., Takeda M., Wada S., Yamaguchi T. Radial dispersion of red blood cells in blood flowing through glass capillaries: The role of hematocrit and geometry. Journal of Biomechanics. 2008;41(10):2188–2196. doi: 10.1016/j.jbiomech.2008.04.033. [DOI] [PubMed] [Google Scholar]
- 22.Lima R., Ishikawa T., Imai Y., Takeda M., Wada S., Yamaguchi T. Measurement of individual red blood cell motions under high hematocrit conditions using a confocal micro-PTV system. Annals of Biomedical Engineering. 2009;37(8):1546–1559. doi: 10.1007/s10439-009-9732-z. [DOI] [PubMed] [Google Scholar]
- 23.Saadatmand M., Ishikawa T., Matsuki N., et al. Fluid particle diffusion through high-hematocrit blood flow within a capillary tube. Journal of Biomechanics. 2011;44(1):170–175. doi: 10.1016/j.jbiomech.2010.09.004. [DOI] [PubMed] [Google Scholar]
- 24.Pinho D., Rodrigues R. O., Faustino V., Yaginuma T., Exposto J., Lima R. Red blood cells radial dispersion in blood flowing through microchannels: The role of temperature. Journal of Biomechanics. 2016;49(11):2293–2298. doi: 10.1016/j.jbiomech.2015.11.037. [DOI] [PubMed] [Google Scholar]
- 25.Imai Y., Kondo H., Ishikawa T., Teck Lim C., Yamaguchi T. Modeling of hemodynamics arising from malaria infection. Journal of Biomechanics. 2010;43(7):1386–1393. doi: 10.1016/j.jbiomech.2010.01.011. [DOI] [PubMed] [Google Scholar]
- 26.Tao Y., Wang T. Analysis of Hematocrit Variation Induced by Malaria-infected Red Blood Cells. DEStech Transactions on Biology and Health. 2018;(icmsb) doi: 10.12783/dtbh/icmsb2017/17969. [DOI] [Google Scholar]
- 27.Lei H., Karniadakis G. E. Quantifying the rheological and hemodynamic characteristics of sickle cell anemia. Biophysical Journal. 2012;102(2):185–194. doi: 10.1016/j.bpj.2011.12.006. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Lei H., Karniadakis G. E. Predicting the morphology of sickle red blood cells using coarse-grained models of intracellular aligned hemoglobin polymers. Soft Matter. 2012;8(16):4507–4516. doi: 10.1039/c2sm07294g. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Li X., Caswell B., Karniadakis G. E. Effect of chain chirality on the self-assembly of sickle hemoglobin. Biophysical Journal. 2012;103(6):1130–1140. doi: 10.1016/j.bpj.2012.08.017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Lei H., Karniadakis G. E. Probing vasoocclusion phenomena in sickle cell anemia via mesoscopic simulations. Proceedings of the National Acadamy of Sciences of the United States of America. 2013;110(28):11326–11330. doi: 10.1073/pnas.1221297110. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Kumar A., Graham M. D. Mechanism of margination in confined flows of blood and other multicomponent suspensions. Physical Review Letters. 2012;109(10) doi: 10.1103/PhysRevLett.109.108102.108102 [DOI] [PubMed] [Google Scholar]
- 32.Wang T., Pan T.-W., Xing Z. W., Glowinski R. Numerical simulation of rheology of red blood cell rouleaux in microchannels. Physical Review E: Statistical, Nonlinear, and Soft Matter Physics. 2009;79(4) doi: 10.1103/physreve.79.041916.041916 [DOI] [PubMed] [Google Scholar]
- 33.Wang T., Xing Z. W. Erythrocyte hemodynamics in stenotic microvessels: a numerical investigation. Physical Review E: Statistical, Nonlinear, and Soft Matter Physics. 2013;88(4) doi: 10.1103/physreve.88.042711.042711 [DOI] [PubMed] [Google Scholar]
- 34.Glowinski R. Finite element methods for incompressible viscous flow. Handbook of Numerical Analysis. 2003;9:3–1176. doi: 10.1016/S1570-8659(03)09003-3. [DOI] [Google Scholar]
- 35.Tsubota K. I., Wada S., Yamaguchi T. Simulation study on effects of hematocrit on blood flow properties using particle method. Journal of Biomechanical Science and Engineering. 2006;1(1):159–170. doi: 10.1299/jbse.1.159. [DOI] [Google Scholar]
- 36.Peskin C. S. Numerical analysis of blood flow in the heart. Journal of Computational Physics. 1977;25(3):220–252. doi: 10.1016/0021-9991(77)90100-0. [DOI] [Google Scholar]
- 37.Maeda N., Suzuki Y., Tanaka J., Tateishi N. Erythrocyte flow and elasticity of microvessels evaluated by marginal cell-free layer and flow resistance. American Journal of Physiology-Heart and Circulatory Physiology. 1996;271(6):H2454–H2461. doi: 10.1152/ajpheart.1996.271.6.H2454. [DOI] [PubMed] [Google Scholar]
- 38.Kondo H., Imai Y., Ishikawa T., Tsubota K.-I., Yamaguchi T. Hemodynamic analysis of microcirculation in malaria infection. Annals of Biomedical Engineering. 2009;37(4):702–709. doi: 10.1007/s10439-009-9641-1. [DOI] [PubMed] [Google Scholar]
- 39.Pinho D., Campo-Deaũo L., Lima R., Pinho F. T. In vitro particulate analogue fluids for experimental studies of rheological and hemorheological behavior of glucose-rich RBC suspensions. Biomicrofluidics. 2017;11(5) doi: 10.1063/1.4998190.054105 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Flatt C., Mitchell S., Yipp B., Looareesuwan S., Ho M. Attenuation of cytoadherence of Plasmodium falciparum to microvascular endothelium under flow by hemodilution. The American Journal of Tropical Medicine and Hygiene. 2005;72(6):660–665. [PubMed] [Google Scholar]
- 41.Zhang Y., Huang C., Kim S., et al. Multiple stiffening effects of nanoscale knobs on human red blood cells infected with Plasmodium falciparum malaria parasite. Proceedings of the National Acadamy of Sciences of the United States of America. 2015;112(19):6068–6073. doi: 10.1073/pnas.1505584112. [DOI] [PMC free article] [PubMed] [Google Scholar]