Abstract
Background
Perfusion assessment of the pancreas is challenging and poorly evaluated. Pancreatic affection is a prevalent feature of cystic fibrosis (CF). Little is known about pancreatic perfusion in CF. We aimed to assess pancreatic perfusion by contrast-enhanced ultrasound (CEUS) analysed in the bolus-and-burst model and software.
Methods
We performed contrast enhanced ultrasound of the pancreas in 25 CF patients and 20 healthy controls. Perfusion data was analysed using a dedicated perfusion model providing the mean capillary transit-time (MTT), blood flow (BF) and blood-volume (BV). CF patients were divided according to exocrine function.
Results
The pancreas insufficient CF patients had longer MTT (p ≤ 0.002), lower BF (p < 0.001) and lower BV (p < 0.05) compared to the healthy controls and sufficient CF patients. Interrater analysis showed substantial agreement for the analysis of mean transit time.
Conclusion
The bolus-and-burst method used on pancreatic CEUS-examinations demonstrates reduced perfusion in CF patients with pancreas affection. The perfusion model and software requires further optimization and standardization to be clinical applicable for the assessment of pancreatic perfusion.
Electronic supplementary material
The online version of this article (10.1186/s12880-018-0259-3) contains supplementary material, which is available to authorized users.
Keywords: Contrast enhanced ultrasound, Pancreas, Perfusion, Exocrine pancreatic function, Cystic fibrosis
Background
Non-invasive measurements of pancreatic perfusion have been performed by contrast-enhanced ultrasound (CEUS) [1–5], perfusion Computer tomography (CT) [6, 7] and magnetic resonance imaging (MRI) [8]. Attempts at an in-vivo reference standard have been made using hydrogen gas clearance method under laparoscopy [9] and endoscopy [10]. In a recent review of the methods, not including CEUS, Tsushima et al. reported median value of normal pancreatic perfusion from several studies around 100 mL/min/100 mL of pancreatic tissue, with individual values ranging from 38.4 to 356 mL/min/100 mL [7]. A standard for the clinical use of CEUS dealing with pancreatic lesions has been suggested [4]. However, a clinical application of pancreatic perfusion measures has not been established.
CEUS by gas-filled microbubbles is commonly used to assess relative perfusion parameters in various organs [4, 11–13]. In the gut CEUS modelling of perfusion can be used for separating inflammatory from fibrotic processes [12, 14]. In the pancreas perfusion can be useful in a clinical setting such as characterizing tumours [2, 15] and in the evaluation of other focal pancreatic lesions [16]. One study was able to demonstrate reduced perfusion in chronic pancreatitis patients compared to healthy controls [10], and attempts have been made to define perfusion changes in early chronic pancreatitis [5].
Most integrated tools on the ultrasound scanners provide models to calculate parameters from the time intensity curve [2, 10, 14, 15]. Often the models are inaccurate, and analysis is performed offline on exported data sets [14, 17]. A unique feature of microbubbles is that they can be cleared from the bloodstream using a burst of ultrasound with a high mechanical index. Recently, Jirik et al. developed a method for estimating absolute perfusion parameters; the bolus-and-burst technique [18]. The pharmacokinetic model used allows the estimation of the mean capillary transit time (MTT), the blood volume (BV), and also blood flow (BF) using the central volume theorem, BF = BV/MTT [18, 19]. The integral of the time-intensity curve in a vessel (artery or vein) is used for scaling the data and calculate absolute values for blood flow and blood volume. The model has earlier been related to pathological findings and clinical outcome data in the intestines of patients with Crohn’s disease [12]. We recently evaluated the inter observer and inter system quality of the model in the pancreas [20].
Patients with cystic fibrosis (CF) develop pancreatic damage as a result of defective ductal and acinar pancreatic secretion [21, 22]. The main pathological findings in the affected CF pancreas are homogenous atrophy, fibrosis and fatty infiltration, whereas the more focal features of chronic pancreatitis are not frequently seen [21, 23]. The microvascular changes and perfusion characteristics in CF are not well described in literature. Autopsy studies of chronic pancreatitis patients have shown marked reduction in pancreatic vasculature with reduced number, volume and calibre changes of the vessels [24]. It is assumed that the same reduction of microvascular density is present in the affected CF pancreas. The possibility of precise pancreas phenotype characterization, and a marked, homogenous pathological difference between normal and affected tissue, makes CF patients a good model population for examining pancreas perfusion.
The aim of this study was to assess absolute perfusion parameters in the pancreas using bolus-and-burst technique [12, 18, 19] in patients with CF and healthy controls. Furthermore, the interrater agreement of the model-analysis was evaluated.
Methods
Subjects
During a 4-year period (December 2010–May 2014), CF patients aged > 15 years attending regular follow up in the CF clinic were offered a detailed evaluation of the pancreas in this prospective observational study. The CF diagnosis was defined according to the present diagnostic criteria for CF in the cystic fibrosis foundation consensus report [25, 26]. A group of healthy controls was also included. Inclusion criteria for the control group were absence of abdominal symptoms and disease. Subjects with insufficient sonographic visualisation of the pancreas, extensive respiratory movements or technical flaws in the recorded perfusion/reperfusion phases were excluded retrospectively.
Patient characteristics
Patient records were reviewed and all subjects were interviewed. Age and sex of the patient, body mass index, CFTR mutation status and sweat-test values (Cl−) were documented.
Transabdominal ultrasound
The subjects were fasting > 4 h. A GE Logic E9 scanner with a 1-5 MHz curvilinear-probe was used (General Electric medical systems and primary care diagnostics, Milwaukee, WI, USA). Scanning of the pancreas was performed with the subjects in supine position, using a transverse or oblique epigastric probe position. An intravenous bolus of 1.5 mL SonoVue® contrast agent (Bracco, Milan, Italy) was given over 2 s followed by a bolus of 10 ml saline over 4 s. The dual view containing both the B-mode and the contrast image was used for the acquisition. Recordings were acquired for 90 s with the following settings: Dynamic range 66, 9 frames per second, probe frequency 4 MHz and mechanical index: 0.10. The focus position was placed at the deepest point of the pancreas. When the contrast intensity reached a steady state (after 45 s) a high-power pulse sequence was applied to burst the bubbles, and the replenishment phase was recorded for 45 s. Recordings were stored as Digital Imaging and Communications in Medicine (DICOM)-files for later analysis.
Image processing and analysis
Exclusion of datasets
To ensure relevant and good quality data, a strict exclusion procedure was applied. Datasets with generally insufficient imaging quality or particularly with disturbances in the reperfusion phase were excluded prior to the final analysis. Exclusions were made blinded to patient characteristics. Post analysis exclusions of outliers represented by MTT > 15sek were performed to exclude non-physiological values from the analysis.
Image processing and analysis
Contrast images with chosen ROIs and corresponding perfusion curves are illustrated in Fig. 1.
Manual motion correction
To reduce the size of the data sets and thus computational load, the sequences were automatically subsampled to 3 frames per second. Furthermore, a manual single frame exclusion procedure and movement correction was performed using a perfusion analysis calculation-software (DCE-US, http://info.isibrno.cz/perfusion/) implemented in MATLAB (Version R2014a, Mathworks Inc., Massachusetts, USA) as previously described [27]. The calculations in the DCE-US software were performed within a defined region of interest (ROI) in the pancreas after the motion correction and frame exclusion. The ROI was chosen in a region of the pancreas with minimal residual motion and other artefacts. The size and form of the ROI had to be adjusted according to this, excluding the possibility of a standardized ROI for all patients. An anatomical location in the head or body of the pancreas was preferred, but sample quality had priority over exact standardization of anatomical location. For the scaling procedure an artery close to the chosen ROI (mainly superior mesenteric or gastroduodenal artery) was identified. If necessary a second motion correction process was performed before a ROI was drawn and the integral of the arterial tissue concentration curve calculated.
The manual motion correction and perfusion analysis was performed by clinicians experienced (> 5 years) with pancreatic ultrasound and blinded to knowledge of pancreatic function and clinical data.
Perfusion analysis
In Fig. 1 we present the perfusion curves for selected parts of the pancreas in two patients. The complex mathematical calculations in the bolus-and-burst perfusion-analysis model are described in detail by Jirik et al. [18, 19]. It provides estimates of the physiological parameters blood volume (BV [mL/100 mL]), mean capillary transit time (MTT [s]) and blood flow (BF [mL/min/100 mL tissue]) calculated as BF = BV/MTT*60. The perfusion model includes a scaling factor required for absolute quantification of blood volume and flow [18, 19] derived from the area under the curve of the arterial tissue concentration curve.
Interrater analysis
Before analysis the DICOM files were randomized, using a web based free-ware, Research Randomizer [28]. The perfusion analysis was performed by two observers (KN and TE). The results from observer 2 were used for interrater analysis only.
Exocrine pancreas function
We assessed exocrine pancreatic function by a secretin stimulated, short endoscopic function test described elsewhere [29, 30]. Faecal elastase-1 was measured by a commercial analysis kit (ScheBo, Biotech, Giessen, Germany). The CF patients were defined as pancreas sufficient by faecal elastase > 100 μg/g or duodenal bicarbonate > 80 mmol/L.
Statistical analysis
Statistics were calculated in SPSS statistics 22 (IBM SPSS Statistics, New York, USA) and SigmaPlot 11, (Systat Software Inc., San Jose, CA, USA). Normal distribution of the samples was tested by Kolmogorov-Smirnov test. The results are presented as median values with IQ range. Simple comparisons between groups were made Mann-Witney U-test. Accuracy data are calculated from receiver operator curves (ROC). Variance is expressed through 95% confidence intervals. 5% level of statistical significance was used. Correlation was calculated using Pearson’s correlation coefficient. Interrater reliability was calculated as intra-class correlation coefficients (ICC) in a random, two-way analysis. The ICC has values between 0 and 1 and is considered poor if 0–0.2, fair if 0.2–0.4, good if 0.4–0.75 and excellent if > 0.75. The scaled data were analysed according to consistency. Agreement was defined according to Landis and Koch [31]: 0 = no agreement, 0 - 0.20 = slight agreement, 0.21–0.40 = fair agreement, 0.41- 0.60 = moderate agreement, 0.61–0.80 = substantial agreement and 0.81–1 = almost perfect agreement. Bland-Altman plots were drawn. Power and number of patients at baseline are calculated based on the following assumptions: The smallest difference between the groups rejecting the null hypothesis is estimated to 35%. The worst case standard deviation is chosen 25%. Sample sizes of 14 patients in each group are expected to give the desired power of at least 0.80.
Results
Inclusion
The inclusion flow chart is displayed in Fig. 2. We examined 33 CF patients and 25 healthy controls according to the protocol. We excluded 8 CF patients and 5 controls due to poor pancreatic ultrasound visualisation, or failure to track the same region of interest throughout the examination. Accordingly, we present results from 25 CF patients and 20 healthy controls (HC). When sorted by exocrine pancreatic function, patient groups were divided as follows: Cystic fibrosis; pancreatic insufficient (CFI, n = 13) and cystic fibrosis; pancreatic sufficient (CFS, n = 12). Observer 2 failed to achieve analysis for four of 45 subjects analysed by observer 1. Further three analyses were excluded from the analysis performed by observer 2 due to non-physiological values (MTT > 15 s), leaving 38 analyses for the interrater agreement analysis. Demographic data and data for exocrine function are displayed in Table 1. The control group was slightly older and contained more females than the CF groups (p < 0.05).
Table 1.
CFI (n = 13) | CFS (n = 12) | HC (n = 20) | p | |
---|---|---|---|---|
Age | 21 (16–52) * | 21 (16–70)* | 26 (18–66) * | |
Gender (♀/♂) | 6 / 7 | 6 / 6 | 13 / 7 | |
Body mass index | 21 (19–23) | 22 (21–25) | 22 (20–25) | |
Sweat [Cl−] | 113 (100–130) | 72 (66–78) | – | *** |
F-Elastase (μg/g) | 0 (0–2) | 571 (512–612) | – | *** |
D-bicarbonate (meq/L) | 11 (11–19) | 118 (96–130) | – | *** |
Values are expressed as medians (IQ range) unless otherwise stated (*Median (Range) (CFI/ CFS: Cystic fibrosis insufficient/ sufficient, HC: Healthy controls). *: < 0.05, **: < 0.01, *** < 0.001)
Perfusion parameters and exocrine function
We calculated BF in mL/min/100 mL, BV in mL/100 mL and MTT in seconds in all three patient groups based on values from of observer 1.
The results are displayed in Table 2 and Fig. 3. Pancreatic insufficient CF patients had significantly longer MTT (p ≤ 0.002), lower BF (p < 0.001) and lower BV (p < 0.05) compared to healthy controls and pancreatic sufficient CF patients. Pearson correlations between duodenal bicarbonate and perfusion parameters gave the following results: MTT: r = − 0.58, p = 0.008, BV r = 0.45, p = 0.046, BF: r = 0.44, p = 0.05. Best differentiation between CFI and CFS was made using MTT and blood flow. A difference between pancreas sufficient CF patients and healthy controls was not observed. Calculated blood flow values in our healthy control group were comparable to values obtained by other methods [7, 9].
Table 2.
CFI (n = 13) | CFS (n = 12) | HC (n = 21) | p | |
---|---|---|---|---|
MTT (s) | 6.9 (5.3–11.3) | 3.6 (2.2–5.3) | 2.5 (2.0–4.0) | ** |
BV (ml/100 mL) | 2.1 (1.2–3.5) | 4.2 (2.5–5.3) | 3.9 (2.7–7.1) | * |
BF (ml/min/100 ml) | 17 (13–22) | 82 (44–97) | 110 (59–165) | *** |
Values are expressed as median (IQ range). There is no difference between CFS and HC group. Concerning difference in BF for these two groups, the power is below desired level
Diagnostic accuracy
We also calculated receiver operator curves (Fig. 4) expressing the diagnostic quality of the three parameters in predicting exocrine pancreatic failure. Sensitivity and specificity for the suggested cut-offs are displayed in Table 3.
Table 3.
Sensitivity | Specificity | Cutoff | Accuracy | |
---|---|---|---|---|
MTT | 0.77 [0.46–0.95] | 0.78 [0.60–0.91] | 5.0 | 0.92 |
BV | 0.69 [0.39–0.91] | 0.72 [0.53–0.86] | 3.0 | 0.80 |
BF | 1.0 [0.75–1.0] | 0.88 [0.71–0.96] | 45 | 0.98 |
Table displaying values for diagnostic accuracies for the corresponding cut-offs. Values in means [95%CI]
Interrater quality
The parallel results from observer 1 and 2 were compared. The agreement for all values is presented as Bland-Altman plots in Fig. 5. Inter-correlation coefficient (ICC [95%CI]) was calculated for all three parameters and demonstrated excellent agreement for MTT (ICC 0.78 [0.62, 0.88]) where the differences between the observations were non-different from zero and linear regression detected no bias through the range of MTT. For the two other parameters the agreement was moderate (BV: ICC 0.44 [0.14, 0.67], BF: ICC 0.48 [0.19, 0.69]. A single variable t-test demonstrated that the difference between the observed values for these parameters differs from zero (p < 0.05), and linear regression detected a fixed bias with a higher values in the calculations from observer 2.
Discussion
We calculated absolute pancreatic perfusion parameters using the bolus-and-burst method applied on data from contrast-enhanced ultrasound of the pancreas in CF patients and healthy controls. The results were related to exocrine pancreatic function. We demonstrate two main findings: First, we show that pancreatic perfusion in pancreatic insufficient CF patients is reduced compared to pancreatic sufficient patients and healthy controls. Secondly we found that the reduced perfusion calculated in our absolute perfusion model in CF patients predicts exocrine pancreatic insufficiency in CF with an acceptable diagnostic accuracy. Accordingly, CEUS with absolute perfusion analysis in the bolus-and burst model may non-invasively differentiate between healthy pancreatic tissue and exocrine insufficient pancreatic tissue due to CF. For the inter-rater quality of the analysis process we find excellent agreement for MTT, whereas the two other parameters demonstrate a fixed bias between the raters.
Presently, this is the only study describing perfusion aspects in the CF pancreas. The CF pancreas was chosen to evaluate the CEUS bolus-and-burst method due to the clear and homogenous discrimination between healthy and abnormal tissue. The exocrine function in our population was either normal or very low. This finding was distinctly reflected in the distribution of the bicarbonate levels between individuals with a healthy or affected pancreas. By the combination of faecal elastase and endoscopic short test to define exocrine pancreatic function we provide a strict and accurate definition of pancreas sufficiency [29]. Few results in the intermediate range reduce the value of correlation studies between perfusion and exocrine function parameters. However, the perfusion parameters still demonstrate acceptable correlation to exocrine pancreatic function.
The literature describing the vascularity of the affected CF pancreas is lacking, but due to the described severe fatty infiltration and progression towards atrophy, fibrosis and degeneration of normal anatomy [23], we assume that the vascular density in the pancreas is reduced. This hypothesis fits our findings where measured blood volume and the calculated blood flow are reduced and the transit time is increased in the affected pancreas. The clinical application of this finding in CF diagnostics is possibly limited, but the ability to differ between tissues with normal and reduced perfusion may be more relevant in other diseases. The clinical application of CEUS in the differential diagnostics of pancreatic tumours is already established [4]. Furthermore, particularly in chronic pancreatitis the gland may be focally destroyed due to obstructive causes. In this setting, the discrimination between vital tissue connected to recent changes and more irreversibly destroyed tissue due to longstanding changes could be relevant for the therapeutic decision process.
Contrast-enhanced ultrasound of the pancreas infers several challenges both in image quality, reproducibility and standardisation. In this study we exported the image data and used a non-integrated perfusion analysis tool instead of the widespread integrated tools. The advantages of tools integrated in the scanners are better availability and clinical feasibility. However, questions have been raised about the variability of these tools in different scanners and the validity of the mathematical model using log-converted time-intensity data [18, 19, 32]. One study achieved acceptable improvements in interrater reproducibility for a range of perfusion parameters both in vivo and vitro using the bolus method and taking into account the arterial input function and a mathematical model based on deconvolution [32].
In the model from Jirik et al., absolute perfusion can be calculated using a combination of the bolus and the burst-replenishment methods. The scaling of the data to the area under the curve of the TIC from a local artery enables accurate estimates of both time and amplitude related variables such as mean transit time and blood volume, respectively [18, 19]. The disadvantage of the chosen method compared to the integrated models, is the complexity of the analysis which includes several steps of motion compensation, removal of off-plane images, ROI selection and selection of small, difficult-to trace arteries for scaling. The process is manual and time-consuming, and contains several steps prone to introduce variability. Both raters demonstrated reduced perfusion and prolonged transit time in the affected CF pancreas, but our analysis revealed less than desired quality in interrater agreement. The methodological complexity probably explains the variation between the observers. Although the model infers complicated mathematics and the software still is in beta-version, we advocate that the advantages of absolute perfusion parameters and transferability between different ultrasound systems justify further validation of this model.
Limitations of study
We have demonstrated previously that pancreas sonography is feasible in most CF patients [33]. The localisation of the pancreas deeply in the abdomen behind other air-containing organs like the colon, the ventricle and the duodenum can cause permanent or intermittent disturbances. This affects an analysis dependent on observation over time. To deal with these challenges we excluded patients with poor image quality, and performed motion correction and frame exclusions as described above. This introduces possible exclusion bias. The number of subjects in each group after exclusions was slightly below calculations for desired power, thus non-significant differences should be interpreted with caution.
Blinding the operators to information on subject characterisation and exclusions in the pre-analytic stage were measures taken to reduce the risk of such biases. We acknowledge that a high number of exclusion is a limitation of the clinical usefulness of the method. However, we argue that these measures make the final perfusion assessment less prone to imaging disturbances and improve the physiological reliability of the results.
In a clinical setting, the usefulness of the method depends on adequate standardisation and quality of the CEUS recordings, and subsequently high quality motion correction. Difficulties in standardization of position, form and size of the ROIs may be a limitation introducing variations.
Forthcoming software improvements to reduce the number of manual steps and to automatize tissue recognition will most likely increase interrater agreement.
Conclusions
We found that CEUS in the chosen absolute perfusion model may non-invasively differentiate between healthy and affected pancreatic tissue due to CF. To our knowledge there are no other studies estimating perfusion in the CF pancreas or relating the perfusion to exocrine function. A good clinical standard for the evaluation of pancreatic tissue perfusion is presently non-existing. The CEUS acquisition and perfusion estimation in the bolus–and-burst model requires further optimization to be widely clinical applicable for the assessment of pancreatic perfusion.
Additional file
Acknowledgements
We give our special acknowledgement to the supporting laboratory technicians Liv Aasmul and Aud Sissel Hjartholm for preserving and running analyses on duodenal juice and to Line Lærum for always keeping the spirit up in the attending CF patients.
Funding
The authors have received independent travel grants and scholarships from the Norwegian Gastroenterology association and the Norwegian cystic fibrosis foundation. The project was also supported by Ministry of Education, Youth and Sports of the Czech Republic. The funders had no role in the design of the study, in collection, analysis, or interpretation of data and writing the manuscript.
Availability of data and materials
Data underlying the conclusions in the study contain clinical information on humans and publication of the data material is subject to legal restrictions. An anonymized data file is provided as additional file [Additional file 1].
Abbreviations
- BF
Blood flow
- BV
Blood-volume
- CEUS
Contrast enhanced ultrasound
- CF
Cystic fibrosis
- CFI/CFS
Cystic fibrosis pancreas insufficient/sufficient
- CFTR
Cystic fibrosis transmembrane receptor protein
- CT
Computer tomography
- DICOM
Digital Imaging and Communications in Medicine
- HC
Healthy controls
- ICC
Intra-class correlation coefficients
- IQ-range
Interquartile range
- MRI
Magnetic resonance imaging (MRI)
- MTT
Mean capillary transit-time
- ROI
Region of interest
- SD
Standard deviation
- TIC
Time intensity curve
Authors’ contributions
TE planned the study, performed patient inclusion, sonographic examinations, data analysis and statistics and wrote the manuscript. KN performed data analysis and statistics and contributed in study planning and writing. FE, MS, BNL and OHG assisted in project planning, patient inclusion and writing. MM and RJ was responsible for the software model and assisted in writing. GD was principal investigator and contributed in all phases of the study. All authors have read and approved the final version of the article.
Ethics approval and consent to participate
The protocol and publication of the results was approved by the local ethical committee. (Regional ethical committee, western Norway https://helseforskning.etikkom.no// Mail: rek-vest@uib.no) Approval number: REK: 2010/2857–7. The study was performed in accordance with the Helsinki Declaration [34]. All subjects signed an informed consent form. For patients between 15 and 18 years consent was also signed by parents. The consent forms were approved by the local ethical committee.
Consent for publication
The publication of anonymized medical images was approved by the participants.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Footnotes
Electronic supplementary material
The online version of this article (10.1186/s12880-018-0259-3) contains supplementary material, which is available to authorized users.
Contributor Information
Trond Engjom, Phone: +47920489852, Email: trond.engjom@helse-bergen.no.
Kim Nylund, Email: kim.nylund@helse-bergen.no.
Friedemann Erchinger, Email: friedemann.erchinger@helse-bergen.no.
Marcus Stangeland, Email: marcusstangeland@gmail.com.
Birger Norderud Lærum, Email: birgernl@me.com.
Martin Mézl, Email: mezl@feec.vutbr.cz.
Radovan Jiřík, Email: jirik@feec.vutbr.cz.
Odd Helge Gilja, Email: odd.gilja@helse-bergen.no.
Georg Dimcevski, Email: Georg.dimcevski@gmail.com.
References
- 1.D'Onofrio M, Zamboni G, Faccioli N, Capelli P, Pozzi MR. Ultrasonography of the pancreas. 4. Contrast-enhanced imaging. Abdom Imaging. 2007;32(2):171–181. doi: 10.1007/s00261-006-9010-6. [DOI] [PubMed] [Google Scholar]
- 2.Kersting S, Konopke R, Kersting F, Volk A, Distler M, Bergert H, Saeger HD, Grutzmann R, Bunk A. Quantitative perfusion analysis of transabdominal contrast-enhanced ultrasonography of pancreatic masses and carcinomas. Gastroenterology. 2009;137(6):1903–1911. doi: 10.1053/j.gastro.2009.08.049. [DOI] [PubMed] [Google Scholar]
- 3.Matsubara H, Itoh A, Kawashima H, Kasugai T, Ohno E, Ishikawa T, Itoh Y, Nakamura Y, Hiramatsu T, Nakamura M, et al. Dynamic quantitative evaluation of contrast-enhanced endoscopic ultrasonography in the diagnosis of pancreatic diseases. Pancreas. 2011;40(7):1073–1079. doi: 10.1097/MPA.0b013e31821f57b7. [DOI] [PubMed] [Google Scholar]
- 4.Piscaglia F, Nolsoe C, Dietrich CF, Cosgrove DO, Gilja OH, Bachmann NM, Albrecht T, Barozzi L, Bertolotto M, Catalano O, et al. The EFSUMB guidelines and recommendations on the clinical practice of contrast enhanced ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med. 2012;33(1):33–59. doi: 10.1055/s-0031-1281676. [DOI] [PubMed] [Google Scholar]
- 5.Azemoto N, Kumagi T, Yokota T, Hirooka M, Kuroda T, Koizumi M, Ohno Y, Yamanishi H, Abe M, Onji M, et al. Utility of contrast-enhanced transabdominal ultrasonography to diagnose early chronic pancreatitis. Biomed Res Int. 2015;2015:393124. doi: 10.1155/2015/393124. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Delrue L, Blanckaert P, Mertens D, Van MS, Ceelen W, Duyck P. Tissue perfusion in pathologies of the pancreas: assessment using 128-slice computed tomography. Abdom Imaging. 2012;37(4):595–601. doi: 10.1007/s00261-011-9783-0. [DOI] [PubMed] [Google Scholar]
- 7.Tsushima Y, Miyazaki M, Taketomi-Takahashi A, Endo K. Feasibility of measuring human pancreatic perfusion in vivo using imaging techniques. Pancreas. 2011;40(5):747–752. doi: 10.1097/MPA.0b013e318215ac22. [DOI] [PubMed] [Google Scholar]
- 8.Bali MA, Metens T, Denolin V, De Maertelaer V, Deviere J, Matos C. Pancreatic perfusion: noninvasive quantitative assessment with dynamic contrast-enhanced MR imaging without and with secretin stimulation in healthy volunteers--initial results. Radiology. 2008;247(1):115–121. doi: 10.1148/radiol.2471070685. [DOI] [PubMed] [Google Scholar]
- 9.Ishida H, Makino T, Kobayashi M, Tsuneoka K. Laparoscopic measurement of pancreatic blood flow. Endoscopy. 1983;15(3):107–110. doi: 10.1055/s-2007-1021480. [DOI] [PubMed] [Google Scholar]
- 10.Lewis MP, Lo SK, Reber PU, Patel A, Gloor B, Todd KE, Toyama MT, Sherman S, Ashley SW, Reber HA. Endoscopic measurement of pancreatic tissue perfusion in patients with chronic pancreatitis and control patients. Gastrointest Endosc. 2000;51(2):195–199. doi: 10.1016/S0016-5107(00)70417-2. [DOI] [PubMed] [Google Scholar]
- 11.Claudon M, Dietrich CF, Choi BI, Cosgrove DO, Kudo M, Nolsoe CP, Piscaglia F, Wilson SR, Barr RG, Chammas MC, et al. Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) in the liver--update 2012: a WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS. Ultraschall Med. 2013;34(1):11–29. doi: 10.1055/s-0032-1325499. [DOI] [PubMed] [Google Scholar]
- 12.Nylund K, Jirik R, Mezl M, Leh S, Hausken T, Pfeffer F, Odegaard S, Taxt T, Gilja OH. Quantitative contrast-enhanced ultrasound comparison between inflammatory and fibrotic lesions in patients with Crohn's disease. Ultrasound Med Biol. 2013;39(7):1197–1206. doi: 10.1016/j.ultrasmedbio.2013.01.020. [DOI] [PubMed] [Google Scholar]
- 13.Lassau N, Bonastre J, Kind M, Vilgrain V, Lacroix J, Cuinet M, Taieb S, Aziza R, Sarran A, Labbe-Devilliers C, et al. Validation of dynamic contrast-enhanced ultrasound in predicting outcomes of antiangiogenic therapy for solid tumors: the French multicenter support for innovative and expensive techniques study. Invest Radiol. 2014;49(12):794–800. doi: 10.1097/RLI.0000000000000085. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Saevik F, Nylund K, Hausken T, Odegaard S, Gilja OH. Bowel perfusion measured with dynamic contrast-enhanced ultrasound predicts treatment outcome in patients with Crohn's disease. Inflamm Bowel Dis. 2014;20(11):2029-37. [DOI] [PMC free article] [PubMed]
- 15.D'Onofrio M, Canestrini S, Crosara S, De RR, Pozzi MR. Contrast enhanced ultrasound with quantitative perfusion analysis for objective characterization of pancreatic ductal adenocarcinoma: a feasibility study. World J Radiol. 2014;6(3):31–35. doi: 10.4329/wjr.v6.i3.31. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Fan Z, Li Y, Yan K, Wu W, Yin S, Yang W, Xing B, Li X, Zhang X. Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions--a comparison of conventional ultrasound and contrast-enhanced CT. Eur J Radiol. 2013;82(9):1385–1390. doi: 10.1016/j.ejrad.2013.04.016. [DOI] [PubMed] [Google Scholar]
- 17.Tranquart F, Mercier L, Frinking P, Gaud E, Arditi M. Perfusion quantification in contrast-enhanced ultrasound (CEUS)--ready for research projects and routine clinical use. Ultraschall in der Medizin (Stuttgart, Germany : 1980) 2012;33(Suppl 1):S31–S38. doi: 10.1055/s-0032-1312894. [DOI] [PubMed] [Google Scholar]
- 18.Jirik R, Nylund K, Taxt T, Mézl M, Hausken T, Harabi V, Kol R et al: Parametric ultrasound perfusion analysis combining bolus tracking and replenishment. In: 2012 IEEE International Ultrasonics Symposium: 7–10 Oct. 2012 2012; 2012: 1323–1326.
- 19.Jirik R, Nylund K, Gilja OH, Mezl M, Harabis V, Kolar R, Standara M, Taxt T. Ultrasound perfusion analysis combining bolus-tracking and burst-replenishment. IEEE Trans Ultrason Ferroelectr Freq Control. 2013;60(2):310–319. doi: 10.1109/TUFFC.2013.2567. [DOI] [PubMed] [Google Scholar]
- 20.Stangeland M, Engjom T, Mezl M, Jirik R, Gilja OH, Dimcevski G, Nylund K: Interobserver variation of the bolus-and-burst method for pancreatic perfusion with dynamic contrast-enhanced ultrasound. Ultrasound Int Open 2017: 3 (3):E99-E106. doi: 10.1055/s-0043-110475. Epub 2017 Sep 12. [DOI] [PMC free article] [PubMed]
- 21.Durie PR, Forstner GG. Pathophysiology of the exocrine pancreas in cystic fibrosis. J R Soc Med. 1989;82(Suppl 16):2–10. [PMC free article] [PubMed] [Google Scholar]
- 22.Kopelman H, Corey M, Gaskin K, Durie P, Weizman Z, Forstner G. Impaired chloride secretion, as well as bicarbonate secretion, underlies the fluid secretory defect in the cystic fibrosis pancreas. Gastroenterology. 1988;95(2):349–355. doi: 10.1016/0016-5085(88)90490-8. [DOI] [PubMed] [Google Scholar]
- 23.Kopito LE, Shwachman H. The pancreas in cystic fibrosis: chemical composition and comparative morphology. Pediatr Res. 1976;10(8):742–749. doi: 10.1203/00006450-197608000-00010. [DOI] [PubMed] [Google Scholar]
- 24.Pitkaranta P, Kivisaari L, Nordling S, Nuutinen P, Schroder T. Vascular changes of pancreatic ducts and vessels in acute necrotizing, and in chronic pancreatitis in humans. Int J Pancreatol. 1991;8(1):13–22. doi: 10.1007/BF02930219. [DOI] [PubMed] [Google Scholar]
- 25.Farrell PM, Rosenstein BJ, White TB, Accurso FJ, Castellani C, Cutting GR, Durie PR, Legrys VA, Massie J, Parad RB, et al. Guidelines for diagnosis of cystic fibrosis in newborns through older adults: Cystic Fibrosis Foundation consensus report. J Pediatr. 2008;153(2):S4–S14. doi: 10.1016/j.jpeds.2008.05.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Smyth AR, Bell SC, Bojcin S, Bryon M, Duff A, Flume P, Kashirskaya N, Munck A, Ratjen F, Schwarzenberg SJ, et al. European cystic fibrosis society standards of care: best practice guidelines. J Cystic Fibros. 2014;13(Suppl 1):S23–S42. doi: 10.1016/j.jcf.2014.03.010. [DOI] [PubMed] [Google Scholar]
- 27.Schafer S, Nylund K, Saevik F, Engjom T, Mezl M, Jirik R, Dimcevski G, Gilja OH, Tonnies K. Semi-automatic motion compensation of contrast-enhanced ultrasound images from abdominal organs for perfusion analysis. Comput Biol Med. 2015;63:229–237. doi: 10.1016/j.compbiomed.2014.09.014. [DOI] [PubMed] [Google Scholar]
- 28.Urbaniak G PS: Research Randomizer (Version 4.0). computer software Available at: https://www.randomizer.org. Accessed 10 May 2018.
- 29.Engjom T, Erchinger F, Laerum BN, Tjora E, Aksnes L, Gilja OH, Dimcevski G. Diagnostic accuracy of a short endoscopic secretin test in patients with cystic fibrosis. Pancreas. 2015;44(8):1266–1272. doi: 10.1097/MPA.0000000000000425. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Erchinger F, Engjom T, Tjora E, Hoem D, Hausken T, Gilja OH, Dimcevski G. Quantification of pancreatic function using a clinically feasible short endoscopic secretin test. Pancreas. 2013;42(7):1101–1106. doi: 10.1097/MPA.0b013e3182847a86. [DOI] [PubMed] [Google Scholar]
- 31.Landis J, Koch G. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–174. doi: 10.2307/2529310. [DOI] [PubMed] [Google Scholar]
- 32.Gauthier M, Tabarout F, Leguerney I, Polrot M, Pitre S, Peronneau P, Lassau N. Assessment of quantitative perfusion parameters by dynamic contrast-enhanced sonography using a deconvolution method: an in vitro and in vivo study. J Ultrasound Med. 2012;31(4):595–608. doi: 10.7863/jum.2012.31.4.595. [DOI] [PubMed] [Google Scholar]
- 33.Engjom T, Erchinger F, Laerum BN, Tjora E, Gilja OH, Dimcevski G. Ultrasound echo-intensity predicts severe pancreatic affection in cystic fibrosis patients. PLoS One. 2015;10(3):e0121121. doi: 10.1371/journal.pone.0121121. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.WMA general assembly 2015. World medical association declaration of Helsinki. Ethical Principles for Medical Research Involving Human Subjects. Available at: https://www.wma.net/policies-post/wma-declaration-of-helsinki-ethical-principles-for-medical-research-involving-human-subjects/. Accessed 16 June 2017.
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Data underlying the conclusions in the study contain clinical information on humans and publication of the data material is subject to legal restrictions. An anonymized data file is provided as additional file [Additional file 1].