A quality control method for intensity‐modulated radiation therapy planning based on generalized equivalent uniform dose

Haowen Pang 1,, Xiaoyang Sun 1, Bo Yang 1, Jingbo Wu 1
PMCID: PMC5978717  PMID: 29696777

Abstract

To ensure good quality intensity‐modulated radiation therapy (IMRT) planning, we proposed the use of a quality control method based on generalized equivalent uniform dose (gEUD) that predicts absorbed radiation doses in organs at risk (OAR). We conducted a retrospective analysis of patients who underwent IMRT for the treatment of cervical carcinoma, nasopharyngeal carcinoma (NPC), or non‐small cell lung cancer (NSCLC). IMRT plans were randomly divided into data acquisition and data verification groups. OAR in the data acquisition group for cervical carcinoma and NPC were further classified as sub‐organs at risk (sOAR). The normalized volume of sOAR and normalized gEUD (a = 1) were analyzed using multiple linear regression to establish a fitting formula. For NSCLC, the normalized intersection volume of the planning target volume (PTV) and lung, the maximum diameter of the PTV (left–right, anterior–posterior, and superior–inferior), and the normalized gEUD (a = 1) were analyzed using multiple linear regression to establish a fitting formula for the lung gEUD (a = 1). The r‐squared and P values indicated that the fitting formula was a good fit. In the data verification group, IMRT plans verified the accuracy of the fitting formula, and compared the gEUD (a = 1) for each OAR between the subjective method and the gEUD‐based method. In conclusion, the gEUD‐based method can be used effectively for quality control and can reduce the influence of subjective factors on IMRT planning optimization.

Keywords: gEUD, IMRT, quality control, radiation planning

1. INTRODUCTION

In recent decades, intensity‐modulated radiation therapy (IMRT) has been increasingly used to enable delivery of the highest dose of radiation possible to target tumor regions while minimizing doses delivered to organs at risk (OAR), significantly improving therapeutic ratios.1, 2, 3, 4, 5 In IMRT plan optimization, the experience of the planning physician has a significant influence on the quality of the plan. Typically, physicians provide planners with optimization goals determined from population‐based data, Radiation Therapy Oncology Group (RTOG) guidelines, or clinical knowledge and intuition. Indeed, a lack of effective means for quality control in radiotherapy planning means that the quality of the radiotherapy depends on the experience of the radiation oncology team or center. To address this issue, retrospective optimization analysis was performed for patients who underwent IMRT for the treatment of cervical carcinoma, nasopharyngeal carcinoma (NPC), or non‐small cell lung cancer (NSCLC); the goal of this study was to propose the use of a quality control method based on generalized equivalent uniform dose (gEUD) that predicts absorbed radiation doses in organs at risk (OAR) before IMRT optimization. Several treatment planning systems have been developed that incorporate gEUD cost functions for IMRT optimization. Previous investigations have confirmed the effectiveness of gEUD cost functions for plan optimization.6, 7, 8 For more complex plans, more iterations are required because many parameters need to be finely tuned for dose–volume (DV)‐based objective functions. gEUD was developed with fewer parameter settings to improve the quality of plans.9 The phenomenological form of gEUD is as follows:

gEUD=(1mi=1mdia)1a

where, m is the number of voxels in the anatomical structure of interest, di is the dose in the ith voxel, and a is the tumor or normal tissue specific parameter. For a = ∞, gEUD is equal to the maximum dose; for a = −∞, gEUD is equal to the minimum dose; for a = 1, gEUD is equal to the arithmetic mean dose; and for a = 0, gEUD is equal to the geometric mean dose. Because the mean dose is a critical evaluation condition for OAR, gEUD (a = 1) was used in this study as a restrictive and evaluative condition for OAR to evaluate the quality of radiotherapy planning and reduce the influence of subjective factors on the quality of the radiotherapy plan.

2. MATERIALS AND METHODS

Previous studies have shown a correlation between the radiation dose absorbed by the OAR and the spatial position of the target region.10, 11 In this study, the prescription dose of the target region was considered to be the dose of the intersection area of the OAR and target area. The OAR included the bladder, rectum, and femoral head in patients with cervical carcinoma; the inner ears, oral cavity, parotid gland, larynx, postcricoid region of the hypopharynx, and esophagus in patients with NPC; and the lung in patients with NSCLC.

2.A. Patient information

Patients with cervical cancer, NPC or NSCLC who underwent IMRT planning at our department were randomly selected and divided into data acquisition and data verification groups. The data acquisition group included 50, 65, and 50 patients who underwent IMRT for the treatment of cervical carcinoma, NPC, and NSCLC, respectively. The data verification group included 20 patients with each disease.

2.B. Target delineation

Target delineation was performed in accordance with International Commission on ICRU Reports 50 and 62.12, 13 For cervical carcinoma, the clinical target volume (CTV) was delineated by a radiation oncologist. The margin of CTV to the radiotherapy planning target volume (PTV) was 1 cm in the superior–inferior direction and 0.8 cm in other directions.

For NPC, a radiation oncologist delineated the gross tumors volume (GTV) and clinical target volumes 1 and 2 (CTV1 and CTV2). The GTVs included visible tumors and/or enlarged or suspicious lymph nodes, CTV1 included the high‐risk regions surrounding the primary tumors and the upper neck nodes at risk, and CTV2 included the mid‐lower nodes at risk. The margins of the GTVs, CTV1, and CTV2 were all extended outwards by 3 mm to generate the PGTVs, PCTV1, and PCTV2.

For NSCLC, the GTV and CTV were delineated by a radiotherapist, where PTV = CTV + ITV (internal target volume) + 6 mm. The same radiation oncologist performed target delineation for all patients.

2.C. Prescription dose and plan evaluation

For cervical carcinoma, the prescription dose for the PTV was 48.0–50.4 Gy, and the per fraction doses was 1.80 Gy, which was selected in accordance with the RTOG 0418.14

For NPC, the prescription dose was in accordance with the regulations of the RTOG 0615 and RTOG 0225.15, 16 The prescription dose for the PGTVs was 70 Gy, and the per fraction doses was 2.12 Gy. The PCTV1 treatment dosage was 60–66 Gy, while the per fraction doses was 1.80–2.00 Gy. The PCTV2 prescription dose was 54–56 Gy, and per fraction doses was 1.64–1.70 Gy.

For NSCLC, the prescription dose was selected in accordance with the regulations of the RTOG 0617.17 The prescription dose for the PTV was 60.0–70.0 Gy, and the per fraction doses was 2.00 Gy.

To evaluate the dose distribution of the target, the following parameters were calculated for the PTV: minimal dose delivered to 98% of the target volume (D98%), maximum dose delivered to 2% of the target volume (D2%), conformation number (CN), and homogeneity index (HI) according to ICRU report 83.18 The CN was defined using the following equation:19

CN=TVRITV×TVRIVRI

where CN is the conformation number, TVRI is the target volume receiving the reference isodose, TV is the target volume, and VRI is the volume of the reference isodose. The CN ranged from 0 to 1, where 1 was the ideal value. The HI was calculated using the following equation:18

HI=D2%D98%D50%

where D2% is the near‐maximum dose, D98% is the near‐minimum dose, and D50% is the dose received by half of the PTV. An HI of 0 indicated that the absorbed dose distribution was almost homogenous.

2.D. Limiting requirements for OAR

For cervical carcinoma, the bladder and rectum were restricted to V45 ≤ 50%, V50 ≤ 50% for individual patients, and V50 of the femoral head ≤5%, thus controlling the volume of “hot spots”.14 A window width of 300–500 HU and a window level of 30–50 HU is recommended when the bladder and rectum are delineated, a CT scan slice thickness of 5 mm is also recommended.

For NPC, the mean dose to a unilateral inner ear was ≤45.0 Gy, the mean dose to the oral cavity was ≤40.0 Gy, and the mean dose to the parotid gland was ≤26.0 Gy. In cases where the intersection volume of the parotid gland and PCTV2 was too large, the unilateral D50% was kept at <30.0 Gy or as low as possible, the mean dose to the larynx was ≤45.0 Gy, the mean dose to the postcricoid region of the hypopharynx at ≤45.0 Gy, and the mean dose to the esophagus at ≤45.0 Gy.15, 20, 21, 22 A window width of 1500–2000 HU and window level of 400–450 HU is recommended when the inner ear is delineated. A window width 300–350 HU and window level of 30–50 HU is recommended when the other OAR are delineated; the recommended CT scan slice thickness is 2.5 mm.

For NSCLC, the V20 and V5 of the lung were kept below 30% and 65%, respectively. The mean dose was no more than 20 Gy.23 A window width of 1300–1700 HU and window level of −600 to −800 HU is recommended when the lung is being delineate, and the CT scan slice thickness is recommended to be 2.5 mm.

2.E. IMRT plan design for the data acquisition group

We selected the 6 MV x‐ray co‐planar 7‐beam average divisions (gantry angle at 180°, 128°, 76°, 332°, 280°, and 228°) for cervical carcinoma, 6 MV x‐ray co‐planar 9‐beam average divisions (gantry angle at 160°, 120°, 80°, 40°, 0°, 320°, 280°, and 240°) for NPC, and the 6 MV x‐ray co‐planar 5~8‐beam (gantry angles depending on the tumor location) for NSCLC via the Direct Machine Parameter Optimization (DMPO) algorithm and dose engine (the grid resolution of a 4‐mm dose grid with a 2‐mm fluence grid was used, including the heterogeneity correction) on the Pinnacle3 8.0‐m (Philips, Fitchburg, WI) treatment planning software.

For cervical carcinoma the PTV was extended externally to several rings (0.5 cm in width, considering the large volume of OARs) prior to plan optimization. For NPC the PCTV2 was extended externally to several rings (0.3 cm in width, considering the small volume of OARs) prior to plan optimization.

The intersection areas of ring1~ringn and OAR (ring1~ringn∩OAR) were considered to be independent sub‐organs at risk (sOAR); gEUD (a = 1) for sOAR was regarded as the optimization restrictive condition to make constant adjustments for values and weight. The dose of the intersection area of OAR and the target area was recognized as the prescription dose, and the dose of the target area was guaranteed to keep the absorbed dose of each OAR as low as possible so that the requirements of the evaluation were met. When numerous sOAR were present, sOAR weight parameters were adjusted to smaller values (with respect to the target region). Figure 1 illustrates the intersection area of ring1∼ringn and the right parotid gland in a patient with NPC (case 39).

Figure 1.

Figure 1

The red shadow indicates PCTV2, the purple line indicates the right parotid gland, the yellow line indicates the intersection of ring1 and the right parotid gland (the nearest ring area to the right parotid gland), the green line indicates the intersection of ring4 and the right parotid gland (the middle of ring area to the right parotid gland), and the blue line indicates the intersection of ring7 and the right parotid gland (the farthest ring area to the right parotid gland). There are eight rings in total.

Given the distinctiveness of the lung's position for NSCLC treatment, this study did not divide the OAR into sOAR in patients with NSCLC. During optimization, the values and weights of V5 and V20 were adjusted repeatedly. Under the precondition of meeting the target area's evaluation conditions, V5, V20, and the mean dose to the lung were minimized as much as possible.

2.F. Fitting formula

The following methods were used for cervical carcinoma and NPC in the data acquisition group. Using SPSS 13 software, the Spearman rank correlation test was used to analyze the correlation between volume of sOAR and gEUD (a = 1) of each OAR, and a multiple linear regression analysis was used to fit the experimental data for the normalized volume of sOAR (Vring1∼ringn∩OAR/VOAR) and normalized gEUD (gEUD/Dprescription, a = 1, for cervical carcinoma, Dprescription is the prescription dose of PTV; for NPC, Dprescription is the prescription dose of PCTV2) of each OAR. The following formula was obtained:

Y=Hc+H0×V0+H1×V1++Hn×Vn (1)

where Y is the normalized gEUD (gEUD/Dprescription) of OAR when a = 1; V0 for cervical carcinoma patients is the normalized intersection volume of the PTV and OAR (VPTV∩OAR/VPTV); V0 for NPC patients is the normalized intersection volume of the PCTV2 and OAR (VPCTV2∩OAR/VPCTV2) of each patient; V1 is the normalized intersection volume of ring1 and OAR (sOAR1) of each patient; and analogously, Vn is the normalized intersection volume of ringn and OAR (sOARn) of each patient; Hc and H0–Hn are fitting parameters.

For NSCLC, using SPSS 13 software, the Spearman rank correlation test was used to analyze the correlation between the intersection volume of the PTV and lung, the maximum diameter of the PTV (left–right, anterior–posterior, and superior–inferior), and gEUD (a = 1) of the lung, In addition multiple linear regression analyses were used to fit the experimental data for the normalized intersection volume of the PTV and lung, the maximum diameter of the PTV (left–right, anterior–posterior, and superior–inferior), and normalized gEUD (gEUD/Dprescription) of the lung (a = 1). The following formula was obtained:

Y=Bc+B0×V0+B1×D1+B2×D2+B3×D3 (2)

where Y is the normalized gEUD (gEUD/Dprescription, a = 1) of the lung, V0 is the normalized intersection volume of the PTV and lung (VPTV ∩lung/VPTV), D1 (cm) is the maximum diameter of the PTV (left–right), D2 (cm) is the maximum diameter of the PTV (anterior–posterior), and D3 (cm) is the maximum diameter of the PTV (superior–inferior). Bc, B0, B1, B2, and B3 are fitting parameters.

2.G. IMRT Plan design for the data verification group

Optimization was carried out on 20 patients with each disease using two methods: a subjective method (Method 1) and a gEUD‐based optimization method (Method 2). In Method 1, conventional, experience‐based limits (optimization goals referenced from population‐based data, RTOG guidelines, or clinical knowledge and intuition) were used for the investigated OAR. Method 2 was used to gEUD (a = 1) as the optimization parameter for each OAR, the planner had to repeatedly adjust the optimized parameters of the OARs and target area (gEUD for each OAR was calculated using Formula 1 or 2 just as the reference optimization parameter). The dose of the target area and OARs were guaranteed to satisfy the requirements of the evaluation in Method 1 and Method 2. Using SPSS 13 software, statistical differences were determined using a two‐sided paired t‐test. Differences with a p value of <0.05 were considered significant.

3. RESULTS

The volume of the sOAR had a significant correlation with gEUD (a = 1) of each OAR for cervical carcinoma and NPC in the data acquisition group (all p < 0.05). For Formula 1, Hc and H0–Hn values for different OAR are presented in Table 1. Table 2 summarizes the r‐squared of different OAR for IMRT after the data were fitted using Formula 1. For the bladder, the P‐value was 0.021; for the remaining OAR, P‐values were <0.0001. Taken together, the r‐squared and P‐values suggested that Formula 1 was a good fit.

Table 1.

Hc and H0‐Hn values for IMRT

H OAR
Bladder Rectum Femoral head Inner ear Oral cavity Parotid Larynx Hypopharynx Esophagus
Hc −0.183 −0.290 −0.293 0.427 0.521 0.432 0.549 0.728 0.614
H0 1.176 1.396 0.297 0.714 0.605 0.842 −0.631 0.386 0.582
H1 1.513 1.357 1.328 0.321 0.558 0.457 0.633 0.231 0.194
H2 1.552 1.358 1.329 0.725 0.523 −0.081 0.561 0.263 0.322
H3 1.543 0.878 1.739 −0.167 −0.512 0.175 0.165 −0.691 −0.056
H4 0.875 −0.060 0.004 0.197 0.329 0.156 −0.224 0.000 −0.044
H5 −1.496 2.871 1.046 −0.191 0.609 0.500 0.295 −0.544 −0.313
H6 −0.689 −4.775 0.052 0.226 0.312 −1.275 −0.543 −0.306 −0.053
H7 8.645 2.094 −0.864 −0.495 0.472 0.400 −0.395 −0.982
H8 −5.048 0.395 −2.100 −0.381 −1.032 0.098
H9 6.610 0.352 −0.124 −0.043 0.421
H10 −8.565 −0.472 2.991 −0.586
H11 8.438 −1.259
H12 −3.646 0.202
H13 −2.686
H14 0.483
H15 −1.096

Table 2.

The r‐squared for OAR

r‐squared OAR
Bladder Rectum Femoral head Inner ear Oral cavity Parotid Larynx Hypopharynx Esophagus
r‐squared 0.939 0.941 0.943 0.968 0.916 0.954 0.845 0.912 0.956

The intersection volume of the PTV and lung or the maximum diameter of the PTV (left–right, anterior–posterior, and superior–inferior) significantly correlated with gEUD (a = 1) of lung for NSCLC in the data acquisition group (all P < 0.05). For Formula 2, B c = −0.01, B 0 = 0.189, B 1 = 0.008, B 2 = 0.002, and B 3 = 0.012. The r‐squared was 0.904 (P < 0.0001) suggested that Formula 2 was a good fit.

For the data verification group, gEUDplan1 was calculated using Method 1, gEUDplan2 was calculated using Method 2, and gEUDpred was calculated using Formula 1 or 2. Using δ1 = (gEUDplan1−gEUDpred), δ2 = (gEUDplan2−gEUDpred), the mean δ1 and δ2 values for each OAR in the present study are shown in Table 3. The mean δ1 values of each OAR were significantly higher than the mean δ2 values (P < 0.05); the mean gEUDplan1 values and gEUDpred values of each OAR were significantly different (P < 0.05); the mean gEUDplan2 values and mean gEUDpred values of each OAR were not significantly different (P > 0.05). For cervical carcinoma, NPC, and NSCLC IMRT plans, no significantly different were observed in the D98%, CN, and HI of the target region obtained using Methods 1 and 2 (P > 0.05). The CN and HI for each PTV in the NPC are shown in Table 4.

Table 3.

The mean δ values (cGy)

δ OAR
Bladder Rectum Femoral head Inner ear Oral cavity Parotid Larynx Hypopharynx Esophagus Lung
δ1 364 ± 150 464 ± 284 554 ± 206 325 ± 209 211 ± 291 217 ± 213 729 ± 201 580 ± 249 592 ± 257 318 ± 247
δ2 137 ± 70 168 ± 62 158 ± 101 57 ± 79 100 ± 156 98 ± 127 39 ± 104 81 ± 124 190 ± 118 148 ± 128

Table 4.

Conformation number (CN) and homogeneity index (HI) of nasopharyngeal carcinoma in the data acquisition group for each PTV

Method1 Method2 P
CN
PGTVs 0.58 ± 0.09 0.60 ± 0.08 0.65
PCTV1 0.63 ± 0.08 0.64 ± 0.07 0.57
PCTV2 0.66 ± 0.07 0.67 ± 0.06 0.66
HI
PGTVs 0.06 ± 0.03 0.07 ± 0.03 0.89
PCTV1 0.15 ± 0.04 0.16 ± 0.04 0.92
PCTV2 0.12 ± 0.03 0.14 ± 0.02 0.62

4. DISCUSSION

Quality control of the planned dose of radiation absorbed by OAR during radiotherapy is critically important.24, 25, 26, 27, 28, 29 In the present study, OAR for cervical carcinoma and NPC were divided into sOAR and a multiple linear regression analyses were used to fit the experimental data for sOAR volumes and gEUD (a = 1). For NSCLC, a multiple linear regression analyses were used to fit the experimental data for the intersection volume of the PTV and lung, the maximum diameter of the PTV (left–right, anterior–posterior, and superior–inferior), and gEUD (a = 1). The r‐squared and P values indicated that the fitting formula was a good fit. The volume of sOAR had a significant correlation with the gEUD (a = 1) of each OAR for cervical carcinoma and NPC (all P < 0.05). In addition, the intersection volume of the PTV and lung or the maximum diameter of the PTV (left–right, anterior–posterior, and superior–inferior) had a significant correlation with the gEUD (a = 1) of lung for NSCLC (all P < 0.05) in the data acquisition group which indicated that using sOAR volumes or diameters are able to predict gEUD (a = 1). Our method is a relatively simple mathematical model, which does not require buying new modules of treatment planning software (TPS) or extracting the distance of each sampling point of the OAR with the dose information.

The mean gEUDplan2 values and mean gEUDpred values of each OAR were not significantly different (P > 0.05) which indicated that both Formula 1 and 2 were able to accurately predict achievable gEUD (a = 1). Since IMRT was used and beam apertures are discrete around the patient, the result might be different depending on the volume of the bladder covered, and considering that the beams cover a large volume. This could explain the larger P‐value (P = 0.021); however as P < 0.05, it indicates that Formula 1 is still valid. The mean δ1 values of each OAR were significantly higher than the mean δ2 values (P < 0.05), while no statistically significant differences were observed in the D98%, CN, and HI of the target region using Methods 1 and 2, This shows that Methods 2 can achieve the same target region quality, and better quality for each OAR compared to Method 1.

The process model for the acquisition of sOAR volumes can be edited into scripts to improve efficiency. Simultaneously, more sample data can be added to the original data to yield an updated and more accurate fitting formula. The methods used in the present study can also be applied before planning in other disease states to obtain the predicted value of gEUD when a = 1, that is, as a standard for quality control in radiotherapy planning.

Consider δ, δ closer to 0 indicated a closer relationship between the planned and predicted values of gEUD (a = 1). The δ threshold can be set for standardizing the gEUD (a = 1) of each OAR. The δ above the threshold needs to be further optimized until a satisfactory δ is obtained under the conditions of the target prescription evaluation.

Importantly, there are many other factors that affect the quality of radiotherapy planning, and these factors should be considered in future efforts toward IMRT plan optimization. For example, to better protect OAR, dose reduction around the target area should be discussed by physicists and doctors to reach an appropriate conclusion for individual cases.

Further research through multicentered studies with larger data sets collected from different planning systems and OAR in different diseases is required. If the data set is large enough, the neural network fitting method can be employed to provide a more accurate fit.

5. CONCLUSION

gEUD can be predicted on the basis of the volume of sOAR, the intersection volume of the PTV and OAR, or the maximum diameter of the PTV (left–right, anterior–posterior, and superior–inferior). The gEUD‐based method can be used for quality control means and reduce the influence of subjective factors on IMRT planning optimization.

CONFLICTS OF INTEREST

The authors declare no conflict of interest.

REFERENCES

  • 1. Mell LK, Roeske JC, Mundt AJ, et al. A survey of intensity modulated radiation therapy use in the United States. Cancer. 2003;98:204–211. [DOI] [PubMed] [Google Scholar]
  • 2. Fang FM, Chien CY, Tsai WL, et al. Quality of life and survival outcome for patients with nasopharyngeal carcinoma receiving three‐dimensional conformal radiotherapy VS. intensity‐modulated radiotherapy‐a longitudinal study. Int J Radiat Oncol Biol Phys. 2008;72:356–364. [DOI] [PubMed] [Google Scholar]
  • 3. Wong FC, Ng AW, Lee VH, et al. Whole‐field simultaneous integrated‐boost intensity‐modulated radiotherapy for patients with nasopharyngeal carcinoma. Int J Radiat Oncol Biol Phys. 2010;76:138–145. [DOI] [PubMed] [Google Scholar]
  • 4. Roeske JC, Lujan A, Rotmensch J, et al. Intensity‐modulated whole pelvic radiation therapy in patients with gynecologic malignancies. Int J Radiat Oncol Biol Phys. 2000;48:1613–1621. [DOI] [PubMed] [Google Scholar]
  • 5. Chen MF, Tseng CJ, Tseng CC, et al. Clinical outcome in post hysterectomy cervical cancer patients treated with concurrent cisplatin and intensity‐modulated pelvic radiotherapy: comparison with conventional radiotherapy. Int J Radiat Oncol Biol Phys. 2007;67:1438–1444. [DOI] [PubMed] [Google Scholar]
  • 6. Wu Q, Mohan R, Niemierko A, et al. Optimization of intensity‐modulated radiotherapy plans based on the equivalent uniform dose. Int J Radiat Oncol Biol Phys. 2002;52:224–235. [DOI] [PubMed] [Google Scholar]
  • 7. Semenenko VA, Reitz B, Day E, et al. Evaluation of a commercial biologically based IMRT treatment planning system. Med Phys. 2008;35:5851–5860. [DOI] [PubMed] [Google Scholar]
  • 8. Qi XS, Semenenko VA, Li XA. Improved critical structure sparing with biologically based IMRT optimization. Med Phys. 2009;36:1790–1799. [DOI] [PubMed] [Google Scholar]
  • 9. Wu Q, Djajaputra D, Wu Y, et al. Intensity‐modulated radiotherapy optimization with gEUD‐guided dose‐volume objectives. Phys Med Biol. 2003;48:279–291. [DOI] [PubMed] [Google Scholar]
  • 10. Hunt MA, Jackson A, Narayana A, et al. Geometric factors influencing dosimetric sparing of the parotid glands using IMRT. Int J Radiat Oncol Biol Phys. 2006;66:296–304. [DOI] [PubMed] [Google Scholar]
  • 11. Lian J, Lulin Y, Yaorong G, et al. Modeling the dosimetry of organ‐at‐risk in head and neck IMRT planning: an intertechnique and interinstitutional study. Med Phys. 2013;40:121704. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. International Commission on Radiation Units and Measurements (ICRU) . ICRU Report 50: Prescribing, Recording, and Reporting Photon Beam Therapy. Bethesda, MD: ICRU; 1993. [Google Scholar]
  • 13. International Commission on Radiation Units and Measurements (ICRU) . ICRU Report 62: Prescribing, Recording, and Reporting Photon Beam Therapy (supplement to ICRU Report 50). Bethesda, MD: ICRU; 1999. [Google Scholar]
  • 14. Radiation Therapy Oncology Group . A phase II study of intensity modulated radiation therapy(IMRT) to the Pelvis ± chemotherapy for postoperative patients with either endometrial or cervical carcinoma, RTOG 0418.
  • 15. Radiation Therapy Oncology Group . A phase II study of concurrent chemoradiotherapy using three‐dimensional conformal radiotherapy(3D‐CRT) or intensity‐modulated radiation therapy(IMRT) +Bevacizumab(BV) for locally or regionally advanced nasopharyngeal cancer, RTOG 0615.
  • 16. Radiation Therapy Oncology Group . A phase II study of intensity modulated radiation therapy (IMRT) ±chemotherapy for nasopharyngeal cancer, RTOG 0225. [DOI] [PMC free article] [PubMed]
  • 17. Bradley PJD, Rebecca Paulus BS, Komaki PR, et al. Standard‐dose versus high‐dose conformal radiotherapy with concurrent and consolidation carboplatin plus paclitaxel with or without cetuximab for patients with stage IIIA or IIIB non‐small cell lung cancer (RTOG 0617): a randomised, two‐by‐two factorial phase 3 study. Lancet Oncol. 2015;16:187–199. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Listed N. Special considerations regarding absorbed‐dose and dose‐volume prescribing and reporting in IMRT. ICRU. 2010;10:27–40. [DOI] [PubMed] [Google Scholar]
  • 19. Van'T RA, Mak AC, Moerland MA, et al. A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate. Int J Radiat Oncol Biol Phys. 1997;37:731–736. [DOI] [PubMed] [Google Scholar]
  • 20. Bhandare N, Jackson A, Eisbruch A, et al. Radiation therapy and hearing loss. Int J Radiat Oncol Biol Phys. 2010;76:50–57. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21. Deasy JO, Moiseenko V, Marks L, et al. Radiotherapy dose‐volume effects on salivary gland function. Int J Radiat Oncol Biol Phys. 2010;76:58–63. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Werner‐Wasik M, Yorke E, Deasy J, et al. Radiation dose‐volume effects in the esophagus. Int J Radiat Oncol Biol Phys. 2010;76:86–93. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Marks LB, Bentzen SM, Deasy JO, et al. Radiation dose‐volume effects in the lung. Int J Radiat Oncol Biol Phys. 2010;76:70–76. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Moore LM, Brame RS, Low A, et al. Experience‐based quality control of clinical intensity‐modulated radiotherapy planning. Int J Radiat Oncol Biol Phys. 2011;81:545–551. [DOI] [PubMed] [Google Scholar]
  • 25. Zhu XF, Ge YR, Li TR, et al. A planning quality evaluation tool for prostate adaptive IMRT based on machine learning. Med Phys. 2011;38:719–726. [DOI] [PubMed] [Google Scholar]
  • 26. Appenzoller LM, Michalski JM, Thorstad WL, et al. Predicting dose‐volume histograms for organs‐at‐risk in IMRT planning. Med Phys. 2012;39:7446–7461. [DOI] [PubMed] [Google Scholar]
  • 27. Tol JP, Delaney AR, Dahele M, et al. Evaluation of a Knowledge‐Based Planning Solution for Head and Neck Cancer. Int J Radiat Oncol Biol Phys. 2015;91:612–620. [DOI] [PubMed] [Google Scholar]
  • 28. Yang Y, Ford EC, Wu B, et al. An overlap‐volume‐histogram based method for rectal dose prediction and automated treatment planning in the external beam prostate radiotherapy following hydrogel injection. Med Phys. 2013;40:113–132. [DOI] [PubMed] [Google Scholar]
  • 29. Tol JP, Dahele M, Delaney AR, et al. Can knowledge‐based DVH predictions be used for automated, individualized quality assurance of radiotherapy treatment plans? Radiat Oncol. 2015;10:1–14. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Applied Clinical Medical Physics are provided here courtesy of Wiley