Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2018 Jun 6;8:8692. doi: 10.1038/s41598-018-27011-1

Highly sensitive atomic based MW interferometry

Dangka Shylla 1, Elijah Ogaro Nyakang’o 1, Kanhaiya Pandey 1,
PMCID: PMC5989299  PMID: 29875366

Abstract

We theoretically study a scheme to develop an atomic based micro-wave (MW) interferometry using the Rydberg states in Rb. Unlike the traditional MW interferometry, this scheme is not based upon the electrical circuits, hence the sensitivity of the phase and the amplitude/strength of the MW field is not limited by the Nyquist thermal noise. Further, this system has great advantage due to its much higher frequency range in comparision to the electrical circuit, ranging from radio frequency (RF), MW to terahertz regime. In addition, this is two orders of magnitude more sensitive to field strength as compared to the prior demonstrations on the MW electrometry using the Rydberg atomic states. Further, previously studied atomic systems are only sensitive to the field strength but not to the phase and hence this scheme provides a great opportunity to characterize the MW completely including the propagation direction and the wavefront. The atomic based MW interferometry is based upon a six-level loopy ladder system involving the Rydberg states in which two sub-systems interfere constructively or destructively depending upon the phase between the MW electric fields closing the loop. This work opens up a new field i.e. atomic based MW interferometry replacing the conventional electrical circuit in much superior fashion.

Introduction

Atomic based standards such as time and length is already adopted and established due to their high reproducibility, accuracy, resolution and stability1. Atoms have also been successfully used for DC and AC (MW and RF) magnetometry, reaching impressive sensitivity and spatial resolutions25. Inspired by these successes recently, the atom based MW and RF electrometry has been investigated using the Rydberg states of the atoms611. The success of these experiments for high sensitive electrometry is due to property of the Rydberg states i.e. availability of closely spaced levels (in the range of MW and RF region) with very high electric polarizability. The strength sensitivity for MW field using the traditional antenna method is only upto 10 mV/cm12,13 which is limited by the thermal noise. The sensitivity is improved upto 30 μV/cm using the optical method for the electro-magnetic fields converted by the dipole antenna8,14. The atomic based MW sensor improves the sensitivity further upto 8 μV/cm8 which is limited by the natural decay rate of the ground and the Rydberg states, lasers linewidth, the transit time broadening, and Doppler mismatch between probe and the control lasers. The transit time broadening can be removed completely using the cold atomic cloud, cold atomic beam15, or nano cell16. The Doppler mismatch between probe and the control laser can be removed using the cold atom, nano cell or collimated atomic beam. However, with very simple experimental set-up with Rb cell at room temperature, the strength sensitivity of experimentally demonstrated four level system8 is already three orders of magnitude better than the electrical circuit based MW sensor. Further the frequency range of the atomic based MW sensor is from radio frequency (RF), MW to terahertz regime. Next, the spatial resolution of the atomic based MW sensor is sub-wavelength (λMW/650)17 which is difficult to achieve with traditional antenna method as the dimension of the antenna itself happens to be λMW/2.

The atomic based electrometry is based upon the phenomenon of electromagnetically induced transparency (EIT) in which the absorption property of a probe laser is altered in the presence of control lasers and MW (or RF) field in a four level system. EIT is sensitive to the field’s strength, frequency and the polarization and so the electrometry.

An oscillating electro-magnetic field i.e. MW electric field is characterized by it’s strength/amplitude, frequency, polarization and the phase. The previously studied atomic based MW electrometry is not phase sensitive as EIT in a simple multilevel system, happens to be insensitive to the absolute phase of probe and the control fields but only it’s robustness depends upon the phase stability18.

Phase of the MW fields is detected using traditional MW interferometry which is based upon the electrical circuit, whose performance is greatly limited by its bandwidth and the Nyquist thermal noise1921. Here, we explore a six-level loopy ladder system which replaces the traditional electrical circuits based MW interferometry by the atomic MW interferometry, as the absorption property of the probe laser has phase dependency on the MW fields. This is based upon the interference between two sub-systems driven by the MW fields forming the loop. The limitation of the atomic based MW interferometry is again same as in case of the atomic based MW sensor studied with four-level system6,8 and is not limited by the thermal noise. But this system is two orders of magnitude more sensitive to field strength (upto 80 nV/cm) in comparison to the previously explored system6,8 due to its loopy nature. There are loopy system which has been studied previously and has phase sensitivity but loop is completed using the weak magnetic dipole transition22. In contrast to the previous system this six-level loopy system involves allowed electric dipole transition.

This paper is organized as follows. In the section namely “Method”, we describe the method of realizing the six-level loopy ladder system in Rb and possible experimental set-up. In subsequent sub-section we present the semi-classical model and solution for the relevant density matrix element. Further we provide the physical interpretation of the obtained mathematical solution in terms of the interference between the two sub-systems and in terms of the dressed state picture. In the next section namely “Results” we present various results including the lineshape of the probe absorption, the phase dependency of it, the comparison of the amplitude/strength sensitivity of this system with the previously studied four-level system and the frequency range. Finally in the section namely “Discussion” we give our conclusion for this study.

Method

Realization of the system

The considered six-level loopy ladder system is shown in Fig. 1a. The probe laser at 780 nm is at the D2 line i.e. driving the 5 S1/2 → 5 P3/2 transition in the Rb. The control laser at 480 nm is driving the 5P3/2nryd1S and the three reference MW fields are driving the transition, nryd1Snryd2P, nryd2Pnryd3S and nryd3Snryd4P. The unknown MW field is driving the nryd1Snryd4P. The nryd1, nryd2, nryd3 and nryd4 are rydberg states which are chosen according to the frequency range of the MW field.

Figure 1.

Figure 1

(a) The energy level diagram for loopy ladder system. (b) Transitions shown by the red and green arrow lines are the two sub-system to close the loop. The probe laser (dotted red arrow line) and the control laser (solid blue arrow line) are part of both the sub-system. (c) The typical experimental set up for the phase dependent MW electrometry.

The typical experimental setup for phase dependent MW electrometry is shown in Fig. 1(c) in which a probe laser at 780 nm and a control laser at 480 nm are counter-propagating inside the Rb cell. The four MW control fields are generated by a single frequency synthesizer having arrangements of controlling the frequency, phase and the amplitude or the four different MW field frequencies combined using a frequency combiner (e.g. ZN4PD-02183-S+ from minicircuit company can be operated between 2–18 GHz). The output of the frequency synthesizer or combiner is amplified and fed to MW horn. All four MW fields are propagating perpendicular to the probe and the control lasers with a uniform phase inside the Rb cell.

Semi-classical analysis

The electric field, associated with the transition |i〉 → |j〉 is Eijei(ωijt+φij), where Eij is amplitude, ωij is the frequency and ϕij is the phase. We define Rabi frequency Ωij=dijEijeiφij/ for the transition |i〉 → |j〉 having the dipole moment matrix element dij. Please note that Ωij is a complex quantity which can be written as |Ωij| eiφij, where ϕij is due to the phase of the electric field associated with it. The Rabi frequencies of the probe and the control lasers are Ω12 and Ω23 respectively, whereas Ω34ref, Ω45ref, Ω56ref and Ω36unk are the Rabi frequencies of the MW fields. It is important to note here that the phase of Ω36unk is to be characterized w.r.t to the reference MW fields Ω34ref, Ω45ref and Ω56ref. The superscript ref or unk denotes the reference and unknown MW field respectively.

The total Hamiltonian for this system is given as

H=[i=12Ωi,i+12(eiωi,i+1t+eiωi,i+1t)|ii+1|+i=35Ωi,i+1ref2(eiωi,i+1t+eiωi,i+1t)|ii+1|+Ω36unk2(eiω36t+eiω36t)|36|+h.c.]+j=16ωj|jj| 1

If the energy of the state |i〉 is ℏωi then the general quantum mechanical state of the system is

|Ψ=i16ci(t)|ieiωit 2

We define δ12 = ω12 − (ω2 − ω1) and δ23 = ω23 − (ω3 − ω2) i.e. the detunings of the probe and control lasers from their respective resonance. Similarly δ34 = ω34 − (ω3 − ω4), δ45 = ω45 − (ω5 − ω4), δ56 = ω56 − (ω6 − ω5) and δ36 = ω36 − (ω6 − ω3) are the detunings for the MW fields for the respective transitions. In the rotating frame (i.e with a unitary transformation c1=c1; c2=c2eiδ12t; c3=c3ei(δ12+δ23)t; c4=c4ei(δ12+δ23δ34)t; c5=c5ei(δ12+δ23δ34+δ45)t; c6=c6ei(δ12+δ23δ34+δ45+δ56)t) and using the rotating wave approximation, (where the terms with ei[ωij+(ωjωi)] is dropped out for the transition |i〉 → |j〉 if ωj > ωi) we get following Hamiltonian

H=[0|11|δ12|22|(δ12+δ23)|33|(δ12+δ23δ34)|44|(δ12+δ23δ34+δ45)|55|(δ12+δ23δ34+δ45+δ56)|66|+Ω122|12|+Ω232|23|+Ω34ref2|34|+Ω45ref2|45|+Ω56ref2|56|+Ω36unk2ei(δ34δ45δ56+δ36)t|36|+h.c.] 3

In general, the Hamilitonian H is time dependent except for a particular condition when δ34 − δ45 − δ56 + δ36 = 0.

The time evolution of the density matrix, ρ is given by Linblad master equation as

ρ˙=i[H,ρ]+L[ρ(t)] 4

where, L[ρ(t)] is Linblad matrix and defined as below. L[ρ(t)] =

[Γ21ρ22γ12dec2ρ12γ13dec2ρ13γ14dec2ρ14γ15dec2ρ15γ16dec2ρ16γ12dec2ρ21Γ21ρ22+Γ32ρ33γ23dec2ρ23γ24dec2ρ24γ25dec2ρ25γ26dec2ρ26γ13dec2ρ31γ23dec2ρ32Γ32ρ33Γ34ρ33+Γ63ρ66γ34dec2ρ34γ35dec2ρ35γ36dec2ρ36γ14dec2ρ41γ24dec2ρ42γ34dec2ρ43Γ34ρ33Γ4ρ44γ45dec2ρ45γ46dec2ρ46γ15dec2ρ51γ25dec2ρ52γ35dec2ρ53γ45dec2ρ54Γ5ρ55γ56dec2ρ56γ16dec2ρ61γ26dec2ρ62γ36dec2ρ63γ46dec2ρ64γ56dec2ρ65Γ6ρ66] 5

Where, Γij is the decay of the population from state |i〉 (i = 1, 2, .. to 6) to state |j〉 (j = 1, 2, .. 6) and Γi is the total population decay rate of state |i〉. In the case of the weak probe, the population transfer does not take place and it is completely irrelevant to know the population dynamics between different levels. The only important parameter is Γi and Γj, i.e. the total decay rate of states, which governs the decoherence rate (γijdec) between the two levels |i〉 and |j〉 as γijdec=Γi+Γj2. In addition to the total decay rate of states, the linewidth of lasers driving the transition has to be also included for γijdec. For example, in this study we take the value of γ12dec=2π×3.05MHz, which includes natural radiative decay of excited state, Γ2 = 2π × 6 MHz and the 780 nm laser linewidth of 2π × 50 kHz. We also take γ13dec=γ14dec=γ15dec=γ16dec=γdec=2π×100kHz mainly dominated by the laser linewidths of 780 nm and the 480 nm as compared to the radiative decay rate (=2π × 1 kHz) of the Rydberg states |3〉, |4〉, |5〉 and |6〉7. We also take γdec = 2π × 500 kHz in some cases in order to check it’s stringency.

From Eqs 3, 4 and 5 we get 36 coupled differential equations with the property ρij=ρji. In order to solve these set of coupled equation we adapt similar method as in the case of previously studied multi-level systems23.

In the case of weak probe approximation, there will be no population transfer and hence the time evolution of the population i.e. the diagonal terms of the density matrix such as ρ11, ρ22, ρ33, ρ44, ρ55, and ρ66 can be ignored. Similarly the time evolution of the off-diagonal terms ρij for i = 2; j = 3, 4, 5, 6 and i = 3; j = 4, 5, 6 and i = 4; j = 5, 6 and i = 5; j = 6 can be also ignored. The time evolution of the relevant density matrix element is given below.

ρ˙12=iΩ122(ρ11ρ22)+iΩ232ρ13γ12ρ12ρ˙13=iΩ122ρ23+iΩ232ρ12+iΩ34ref2ρ14+iΩ36unk2ei(δ34δ45δ56+δ36)tρ16γ13ρ13ρ˙14=iΩ122ρ24+iΩ34ref2ρ13+iΩ45ref2ρ15γ14ρ14ρ˙15=iΩ122ρ25+iΩ45ref2ρ14+iΩ56ref2ρ16γ15ρ15ρ˙16=iΩ122ρ26+iΩ36unk2ei(δ34δ45δ56+δ36)tρ13+iΩ56ref2ρ15γ16ρ16 6

Where, γ12=[γ12dec+iδ12],

γ13=[γ13dec+i(δ12+δ23)],γ14=[γ14dec+i(δ12+δ23δ34)],γ15=[γ15dec+i(δ12+δ23δ34+δ45)],γ16=[γ16dec+i(δ12+δ23δ34+δ45+δ56)],

Now, we apply the four-photon resonance condition for the MW fields i.e. δ34 − δ45 − δ56 + δ36 = 0. In this case the system will reach steady state i.e. ρ˙ij=0, for all the elements on the time scale of few tens of 1/Γ2 as shown in Fig. 2. In the weak probe condition and in the steady state, ρ11 ≈ 1, ρ22 ≈ ρ33 ≈ ρ44 ≈ ρ55 ≈ ρ66 ≈ 0 and ρij = ρji ≈ 0 for i = 2; j = 3, 4, 5, 6 and i = 3; j = 4, 5, 6 and i = 4; j = 5, 6 and i = 5; j = 6. Finally, we get the following set of equations

ρ12=i2Ω12γ12+i2Ω23γ12ρ13ρ13=i2Ω23γ13ρ12+i2Ω34refγ13ρ14+i2Ω36unkγ13ρ16ρ14=i2Ω34refγ14ρ13+i2Ω45refγ14ρ15ρ15=i2Ω45refγ15ρ14+i2Ω56refγ15ρ16ρ16=i2Ω36unkγ16ρ13+i2Ω56refγ16ρ15 7

Figure 2.

Figure 2

The normalized absorption, ρ12Γ212 vs Time for Ω23=Ω34ref=Ω45ref=Ω56ref=Γ2, Ω36ukn=0.5Γ2 and δ12 = δ23 = δ34 = δ45 = δ56 = δ36 = 0.

The above equation gives solution for ρ12 as

ρ12=i2Ω12γ121+14|Ω23|2γ12γ131+EITATA1+EITATA2+Int

where,

EITATA1=14|Ω34ref|2γ13γ141+14|Ω45ref|2γ14γ151+14|Ω56ref|2γ15γ16;EITATA2=14|Ω36unk|2γ13γ161+14|Ω56ref|2γ15γ161+14|Ω45ref|2γ14γ15;Int=18|Ω34ref||Ω45ref||Ω56ref||Ω36unk|cos(φ)γ13γ14γ15γ161+14|Ω45ref|2γ14γ15+14|Ω56ref|2γ15γ16;φ=φ36unkφ34refφ45refφ56ref 8

The refractive index, n of the probe laser is related with the density matrix element, ρ12 as n=1+3λp2N/(2π)(Γ2/Ω12)ρ12, where λp(=780 nm) is the wavelength of the probe laser and N is atomic number density24,25. The imaginary part of n is related with the absorption and real part with dispersion. We define the normalized absorption [(Γ212) Im(ρ12)] i.e. for the stationary atoms, the absorption of the probe laser at resonance in the absence of all the control lasers is 1.

In order to verify the approximation made above, we have checked the analytical solution of ρ12 given by the Eq. 8 and the complete numerical solution in the steady state for various values of control fields and detunings. It has excellent agreement between complete numerical and approximated analytical solution as shown in Fig. 3. The solution for ρ12 in Eq. 8 has the following interpretation.

Figure 3.

Figure 3

Comparison of complete numerical solution with the analytical solution for the normalized absorption (Im(ρ12212) vs δ122 of the probe laser with |Ω23|=|Ω34ref|=|Ω45ref|=|Ω56ref|=Γ2, |Ω36unk|=0.5Γ2, ϕ = 0 and δ23 = δ34 = δ45 = δ56 = δ36 = 0.

Interpretation

Interference between two sub-system

Equation 8 looks very complicated but it can be interpreted in the following simple way. The closed loop system can be realized by two open loop sub-systems |3〉 → |4〉 → |5〉 → |6〉 and |3〉 → |6〉 → |5〉 → |4〉 shown with red and green arrows respectively as shown in Fig. 1b. These two sub-system shares a common |1〉 → |2〉 → |3〉 ladder system. In order to understand the absorption property of the probe laser Ω12, we switch on the control fields one by one and in the sequence for the two sub-systems. Firstly, the control laser Ω23 causes transparency for the probe laser Ω12 and known as EIT. For path shown with the red color, the control field Ω34ref recovers the absorption against the EIT created by Ω23 and known as EITA. Again the control fields Ω45ref causes transparency against the EITA created by the Ω23 and Ω34ref, and known as EITAT. Finally the Ω56ref causes absorption against the EITAT created by the Ω23, Ω34ref and Ω45ref, and known as EITATA23 and expressed by EITATA1 in Eq. 8. (In order to understand the transparency and absorption in the sequence, we strongly advice the readers to see the paper23). The other path shown with green color will also cause EITATA by sequence of the control fields Ω36unk, Ω56ref and Ω45ref which is expressed by EITATA2. Further, these two sub-system causing EITATA1 and EITATA2, interferes with each other and expressed by the Int term in the Eq. 8, which is phase(ϕ) dependent.

In the other words, the closed loop |3〉 → |4〉 → |5〉 → |6〉 → |3〉 causes absorption against EIT created by the control laser Ω23. The closed loop has two-open loop sub-systems which interfere destructively (for ϕ = 0) and constructively (for ϕ = π) with each other. As shown in Fig. 4a, for |Ω34ref|=|Ω45ref|=|Ω56ref|=|Ω36unk|=Γ2(γdec), there is a complete transparency at the line center for ϕ = 0. This is due to perfect destructive interference between the two-subsystems as the strength is same for both, i.e. EITATA1 = EITATA2. There is maxi-mum absorption at the line center for ϕ = π as the two sub-systems are interfering constructively. For |Ω34ref|=|Ω45ref|=|Ω56ref||Ω36unk|γdec, there is a absorption peak at the line center for ϕ = 0, as shown in Fig. 4b. This is due to unequal strength of the individual system (EITATA1 > EITATA2), hence the destructive interference between them is not perfect.

Figure 4.

Figure 4

Normalized absorption (Im(ρ12212) vs δ122 of the probe laser with |Ω23|=|Ω34ref|=|Ω45ref|=|Ω56ref|=Γ2, δ23 = δ34 = δ45 = δ56 = δ36 = 0 and (a) |Ω36unk|=Γ2 (b) |Ω36unk|=0.5Γ2.

Dressed state approach

At high Rabi frequencies (much greater than the absorption peaks linewidths) of the control lasers and MW fields, the linewidth of the absorption peak can be explained using dressed state picture. In this condition there is no interference between the absorption peaks as they are well separated from each other. The position of the absorption peak is determined by the eigenvalues of the Hamiltonian associated to the control fields as given below

Hc=[0Ω232000Ω232δ23|Ω34ref|2eiφ340|Ω36unk|2eiφ360|Ω34ref|2eiφ34δ23δ34|Ω45ref|2eiφ45000|Ω45ref|2eiφ45δ23δ34+δ45|Ω56ref|2eiφ560|Ω36unk|2eiφ360|Ω56ref|2eiφ56δ23δ34+δ45+δ56] 9

For general control fields detunings and Rabi frequencies, the position of the absorption peaks will be complicated. However, the expression becomes simpler for zero detuning of control fields and with |Ω23|=|Ω34ref|=|Ω45ref|=|Ω56ref|=Ω, but with arbitrary values of |Ω36unk|. In this condition the positions of the absorption peaks (i.e. eigenvalues of the Hc) are −184Ω2+|Ω36unk|2+(2Ω2+|Ω36unk|2)2+8Ω3|Ω36unk|cosφ, −184Ω2+|Ω36unk|2(2Ω2+|Ω36unk|2)2+8Ω3|Ω36unk|cosφ, 0, 184Ω2+|Ω36unk|2(2Ω2+|Ω36unk|2)2+8Ω3|Ω36unk|cosφ, and 184Ω2+|Ω36unk|2+(2Ω2+|Ω36unk|2)2+8Ω3|Ω36unk|cosφ.

The eigenvectors determines the dressed state in terms of the bare atomic states. For example the normalized eigenvector corresponding to eigenvalue 0 is

1[(1+|Ω36unk|2Ω22|Ω36unk|Ωcosφ)+2]1/2][1|Ω36unk|Ωeiφ0101] 10

This is the central dressed state (or the central absorption peak) and is expressed as [(1|Ω36unk|eiφΩ)|2|4+|6]/[(1+|Ω36unk|2Ω22|Ω36unk|Ωcosφ)+2]1/2. The linewidth of the dressed state or the absorption peak is given in terms of the bare atomic states decay rate. For example, if dressed state is written as C2|2〉 + C3|3〉 + C4|4〉 + C5|5〉 then the linewidth of it will be |C2|2Γ2 + |C3|2Γ3 + |C4|2Γ4 + |C5|2Γ5 Hence the linewidth of the cenetral absorption peak is given by [(1+|Ω36unk|2Ω22Ω36unkΩcosφ)Γ2+Γ4+Γ6]/[(1+|Ω36unk|Ω22Ω36unkΩcosφ)+2] which is phase dependent. In order to crosscheck the expression for the linewidth, we fit (shown with black solid line) the central peak of the normalized absorption obtained by Eq. 8 with Lorentzian profile to find the linewidth for three different phases as shown in Fig. 4. The fitted linewidths for ϕ = 0, ϕ = π/2 and ϕ = π are 0.13Γ2, 0.47Γ2 and 0.64Γ2 respectively, while the calculated linewidths are 0.13Γ2, 0.39Γ2 and 0.54Γ2 respectively. There is a small mismatch between the fitted and the calculated linewidths by the dressed state approach for ϕ = π/2 and ϕ = π. This is because, as we see in Fig. 4, the central absorption peak is broadened for ϕ = π/2 and ϕ = π and the interference between peaks starts playing a role in the modification of the linewidth similar to three level system26.

Results

Probe laser absorption

The normalized absorption (Im(ρ12212) vs probe detuning (δ12) for three different phases, ϕ = 0,π/2 and π is shown in Fig. 4. For the central absorption peak i.e. at δ12 = 0, only the linewidth depends upon the phase but not the position, while both the position and the linewidth depends upon the phase(ϕ) for the other four absorption peaks. This has been explained in the previous section.

Now, we consider the effect of the temperature as lineshape of EIT is significantly changed by the thermal averaging2732. The thermal averaging of ρ12 is done numerically for the room temperature (T = 300 K) for the counter-propagating configuration of the probe (Ω12) and the control laser (Ω23) with wave-vectors k780 and k480 respectively by replacing δ12 with δ12 + k780v and δ23 with δ23 − k480v for moving atoms with velocity v, while the Doppler shift for the MW fields are ignored. Further the ρ12 is weighted by the Maxwell Boltzman velocity distribution function and integrated over the velocity as ρ12Thermal=m2πkBTρ12(v)emv22kBTdv, where kB is Boltzman constant and m is atomic mass of Rb. The integration is done over velocity range which is three times of kBTm. The Doppler averaging changes the absorption profile significantly as shown in Fig. 5. One of the interesting modification is the phase dependency of the probe laser absorption at the zero detunings of the probe. The probe laser absorption is minimum for ϕ = 0 and maximum for ϕ = π as shown with red and blue curve respectively in Fig. 5. This modification is due to mismatch of Doppler shift for probe at 780 nm and the control at 480 nm for moving atom. Please note that without thermal averaging at zero detunings of the probe, control laser and MW fields, probe laser absorption has no significant difference between ϕ = π/2 and π.

Figure 5.

Figure 5

Normalized absorption of the probe laser with thermal averaging (Im(ρ12Thermal212) vs δ122 with |Ω23|=|Ω34ref|=|Ω45ref|=|Ω56ref|=Γ2, |Ω36unk|=0.5Γ2 and δ23 = δ34 = δ45 = δ56 = δ36 = 0.

Phase sensitivity

Sinusoidal behavior

As seen in the previous section that the absorption profile of the probe laser depends upon the phase, ϕ. Please note that the previously studied (i.e. four-level) system611 were insensitive to the phase of the MW field. This is also clear from Eq. 8 in the special case with |Ω34ref|=|Ω45ref|=|Ω56ref|=0, which reduces the six-level loopy ladder system to four-level system and will have no phase dependency.

The probe absorption at room temperature vs the phase ϕ with all the detunings to be zero is shown in Fig. 6. From the plot shown with red open circle in Fig. 6a we observe more than 15% change in the probe absorption for the change of the phase from 0 to π for the chosen combinations of the control Rabi frequencies. In particular, we have chosen low value of |Ω36unk|=0.1Γ2 and the optimized control fields Rabi frequencies i.e. |Ω23| = 2Γ2, |Ω34ref|=1.5Γ2, and |Ω45ref|=|Ω56ref|=4Γ2. The numerical data points (red open circle) are fitted by a function A + Bsin(f ϕ + θ), where A, B, f and θ are kept as free parameters that yields f = 1 and the fitting is shown with black curve in Fig. 6a. Now, choosing a high value of |Ω36unk|=2.5Γ2 and keeping the other parameters unchanged, we observe more than 80% change in the probe absorption for the change of the phase from 0 to π as shown crossed red points, but there is a deviation from sinusoidal behavior. This deviation is compared with the fitted black curve as shown in Fig. 6b. On increasing the value of |Ω34ref| to 3Γ2 and keeping the other parameters unchanged, there is a splitting of the absorption at ϕ = π as shown by the solid circled points in this figure.

Figure 6.

Figure 6

Absorption of the probe laser after thermal averaging in arbitrary scale obtained as (Im(ρ12Thermal))/max(Im(ρ12Thermal)) vs phase ϕ with δ12 = δ23 = δ34 = δ45 = δ56 = δ36 = 0 and (a) |Ω36unk|=0.1Γ2, |Ω23| = 2Γ2, |Ω34ref|=1.5Γ2, and |Ω45ref|=|Ω56ref|=4Γ2. (b) crossed points |Ω36unk|=2.5Γ2, |Ω23| = 3Γ2, |Ω34ref|=2Γ2, and |Ω45ref|=|Ω56ref|=4Γ2, solid circled points |Ω36unk|=2.5Γ2, |Ω23| = 3Γ2, |Ω34ref|=3Γ2, and |Ω45ref|=|Ω56ref|=4Γ2.

Optimization of sensitivity

Now, we maximize the phase sensitivity for this system for given value of |Ω36unk| by using the parameters, Ω23, |Ω34ref|, |Ω45ref|, and |Ω56ref|. In order to do this we define a quantity called sensitivity as S=Im[ρ12Thermal(φ=0)ρ12Thermal(φ=π)]/Im[ρ12Thermal(φ=0)+ρ12Thermal(φ=π)], which is a measure of the phase/strength sensitivity of the system and is to be maximized. For given value of |Ω36unk|, we maximize the S by minimizing 1/S or -S using matlab inbuilt function “fmincon” treating Ω23, |Ω34ref|, |Ω45ref|, and |Ω56ref| as free parameters but bounded in the region from 0 to 5 Γ2. Please note that the values 5Γ2 for Ω23 |Ω34ref|, |Ω45ref|, and |Ω56ref| is well in the experimental reach.

We first consider the case without thermal averaging i.e. T = 0. The maximized sensitivity, Smax vs |Ω36unk| is plotted in Fig. 7(a). The Smax increases with |Ω36unk| and starts saturating around 0.05Γ2. The corresponding maximizing values of Ω23, |Ω34ref|, |Ω45ref|, and |Ω56ref| are also plotted in Fig. 7(b). The optimum value of the Ω23 is as high as possible which is 5Γ2 in this case as it is bounded by this limit. This is more clear from the Fig. 8, where Smax increases with Ω23 and then saturates around Γ2 for any given values of |Ω34ref|, |Ω45ref|, |Ω56ref|, and |Ω36unk|.

Figure 7.

Figure 7

(a) The maximum sensitivity Smax (%) vs |Ω36unk|2 (b) The optimum value of |Ω34ref|2 and |Ω56ref|2 for Smax (shown by left scale), Ω232 and |Ω45ref|2 (shown by right scale) vs |Ω36unk| for δ12 = δ23 = δ34 = δ45 = δ56 = δ36 = 0 and T = 0.

Figure 8.

Figure 8

Smax (%) = Im[ρ12(ϕ = 0) − ρ12(ϕ = π)]/Im[ρ12(ϕ = 0) + ρ12(ϕ = π)] × 100 vs Ω232 for δ12 = δ23 = δ34 = δ45 = δ56 = δ36 = 0, |Ω36unk|=0.005Γ2 and T = 0.

Next, we consider the room temperature case (T = 300 K), which makes the problem a bit more complicated, as the lineshape of the absorption gets modified significantly as described previously. The maximum sensitivity (Smax) vs |Ω36unk| is plotted in the Fig. 9(a). The Smax at T = 300 K is much lower than the case at T = 0 as the saturation point is around |Ω36unk| = 1.5 Γ2 as compared to 0.05Γ2 and hence at T = 0 the system can detect the phase of lower values of |Ω36unk|. Unlike the case of T = 0, in this case for Smax the value of Ω23 ≠ 5Γ2 but has optimum values as shown in Fig. 9(b).

Figure 9.

Figure 9

(a) Smax (%) vs |Ω36unk|2 (b) The optimum value of Ω232, |Ω34ref|2, and |Ω56ref|2 shown by left scale and |Ω45ref|2 shown by right scale vs |Ω36unk|2 for δ12 = δ23 = δ34 = δ45 = δ56 = δ36 = 0 and T = 300 K.

Strength sensitivity

The quantity, S defined above can also be used as a measure of the strength/amplitude sensitivity for |Ω36unk| for the six-level loopy ladder system. Now we compare the strength sensitivity of the six-level loopy ladder system with the previously studied four-level system611. The solution of ρ12 for the four-level system can be obtained from the six-level loopy ladder system by setting |Ω34ref|=|Ω45ref|=|Ω56ref|=0 in Eq. 8 and is given by Eq. 11.

ρ12(4l)=i2Ω12γ121+14|Ω23|2γ12γ131+14|Ω36unk|2γ13γ16 11

The subscript (4l) indicates for four-level system. Further the thermal averaging can be done in a similar fashion as in the case of the six-level system i.e. ρ12(4l)Thermal=m2πkBTρ12(4l)(v)emv22kBTdv. We define the strength sensitivity for the four-level system for unknown |Ω36unk| as change in the absorption in the presence and the absence of the |Ω36unk| normalized by the sum of the two conditions which is mathematically expressed as S = [ρ12(4l)Thermal(|Ω36unk|0)ρ12(4l)Thermal(|Ω36unk|=0)]/[ρ12(4l)Thermal((|Ω36unk|0))+ρ12(4l)Thermal(|Ω36unk|=0)]. We maximize the sensitivity of the four-level system adapting similar method as for the six-level system but with only one optimizing parameter i.e. Ω23.

First, we consider T = 0 case. The maximized strength sensitivity for the six-level loopy ladder system and the four-level system is compared in Fig. 10. From this figure it is clear that the six-level system has more sensitivity as compared to the four-level system as shown in Fig. 10(a). In order to quantify this comparison, we plot the ratio of the sensitivities of the six-level to four-level system in Fig. 10(b). The ratio is more for the low values of the |Ω36unk|. The increased sensitivity for the six-level loopy system is due to the interferometric nature of the system where the effect of small |Ω36unk| is enhanced by the large values of the |Ω34ref|, |Ω45ref| and |Ω56ref| as the int term in Eq. 8 involves multiplication of these quantities. The strength sensitivity of both the systems decreases with increased γdec (from 2π × 100 kHz to 2π × 500 kHz) but the effect is more for the four-level system in comparison to the six-level system as shown Fig. 10b.

Figure 10.

Figure 10

(a) Smax(%) vs |Ω36unk|/Γ2 for six-level loopy and four-level ladder system (b) ratio (R) of the sensitivity between six-level and four-level system vs |Ω36unk|/Γ2 at T = 0 with all the detunings to be zero and for γdec = 2π × 100 kHz and γdec = 2π × 500 kHz.

Now, we consider the case at the room temperature. The strength sensitivity for the six-level and previously studied four-level is plotted in Fig. 11(a). Form this plot it is clear that the six-level system has much superior strength sensitivity as compared to the four-level system. Further we quantify the comparison by plotting the ratio (R) of the sensitivities of the six-level to the four-level for different values of |Ω36unk| in Fig. 11(b). In order to check the stringency of γdec on the sensitivity, we also plot Smax for these two systems taking γdec = 2π × 500 kHz.

Figure 11.

Figure 11

(a) Smax(%) vs |Ω36unk|/Γ2 for six-level loopy and four-level ladder system (b) ratio (R) of the sensitivity between six-level and four-level system vs |Ω36unk|/Γ2 at T = 300 K with all the detunings to be zero and for γdec = 2π × 100 kHz and γdec = 2π × 500 kHz.

We also plot the R vs maximum sensitivity (Smax) of the six-level system which gives the information about the possibility of the detection of |Ω36unk|. This is an important plot because there is a possibility that the R might be huge but can not be detected by the six-level system as well. The detection of Smax up to 1% is very much feasible using locking detection. At this value of sensitivity for the six-level system, the sensitivity of the four-level system will be around 1150% as shown in Fig. 12.

Figure 12.

Figure 12

Ratio (R) of the sensitivity between six-level and four-level system vs Smax (%) of the six-level system at T = 300 K. The variation of Smax (%) corresponds to range of |Ω36unk| from 0.005Γ2 to 0.02Γ2.

Finally one more important point is that, for the six-level loopy ladder system the MW field |Ω36unk| can be detected by just varying the phase of the reference MW fields, while in the case of the four-level system we need to insert and remove MW mechanical shield.

Frequency range

The frequency range of the atomic based MW interferometry can be any where from the range of the few tens of MHz, GHz and THz. The rydberg states can be chosen depending upon the interest of the frequency region of MW field. For example, for frequency in the range of few tens of GHz n ryd’s should around 547 while for tens of MHz it should be higher number and it is around 57 in case of Cs9. For THz regime this should be around 2033.

Discussion

In conclusion we theoretically study a six-level loopy ladder system using Rydberg states for the phase sensitive MW or RF electrometry. This is based upon the interference between the two sub-systems of EITATA. In counter-propagating configuration of the probe and control laser there is a change of the lineshape of the probe absorption due to Doppler averaging. The limitation of the proposed system is the decoherence rate between the ground state and the Rydberg states but not the thermal Nyquist noise as in the case of the electrical circuit based MW interferometry. The previously explored four- level atomic system has the same limitation and is already much superior than the electrical circuit for the strength sensitivity, frequency range and spatial resolution. This proposed system further improves the sensitivity by two orders of magnitude, removes the drawback of the phase insensitivity of the previous atomic four level-system and retains the advantages of the large frequency range of operation and spatial resolution. This system provides a great possibility to characterize the MW or RF electric fields completely including the propagation direction and the wavefront. This work will be quite useful for MW and RF engineering hence in the communications specially in active radar technologies and synthetic aperture radar interferometry.

Acknowledgements

K.P. would like to acknowledge the discussion with David Wilkowski at CQT NTU and Sambit Bikas Pal at CQT NUS for this work.

Author Contributions

K.P. conceived the idea and did all the initial calculations, D.S. crosschecked all the calculations and helped in writing the paper, E.O. also crossed checked few calculations and helped in writing the paper. All authors reviewed the manuscript.

Competing Interests

The authors declare no competing interests.

Footnotes

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Hall JL. Nobel Lecture: Defining and measuring optical frequencies. Rev. Mod. Phys. 2006;78:1279–1295. doi: 10.1103/RevModPhys.78.1279. [DOI] [PubMed] [Google Scholar]
  • 2.Budker D, Romalis M. Optical magnetometry. Nat Phys. 2007;3:227. doi: 10.1038/nphys566. [DOI] [Google Scholar]
  • 3.Loretz M, Rosskopf T, Degen CL. Radio-frequency magnetometry using a single electron spin. Phys. Rev. Lett. 2013;110:017602. doi: 10.1103/PhysRevLett.110.017602. [DOI] [PubMed] [Google Scholar]
  • 4.Horsley A, et al. Imaging of relaxation times and microwave field strength in a microfabricated vapor cell. Phys. Rev. A. 2013;88:063407. doi: 10.1103/PhysRevA.88.063407. [DOI] [Google Scholar]
  • 5.Horsley A, Du GX, Treutlein P. Widefield microwave imaging in alkali vapor cells with sub-100 micro m resolution. New Journal of Physics. 2015;17:112002. doi: 10.1088/1367-2630/17/11/112002. [DOI] [Google Scholar]
  • 6.Kubler H, Shaffer JP, Baluktsian T, Low R, Pfau T. Coherent excitation of Rydberg atoms in micrometre-sized atomic vapour cells. Nat. Photon. 2010;4:112. doi: 10.1038/nphoton.2009.260. [DOI] [Google Scholar]
  • 7.Sedlacek JA, Schwettmann A, Kübler H, Shaffer JP. Atom-based vector microwave electrometry using rubidium Rydberg atoms in a vapor cell. Phys. Rev. Lett. 2013;111:063001. doi: 10.1103/PhysRevLett.111.063001. [DOI] [PubMed] [Google Scholar]
  • 8.Sedlacek JA, et al. Microwave electrometry with Rydberg atoms in a vapour cell using bright atomic resonances. Nat. Phys. 2012;8:819. doi: 10.1038/nphys2423. [DOI] [Google Scholar]
  • 9.Jiao Y, et al. Spectroscopy of cesium Rydberg atoms in strong radio-frequency fields. Phys. Rev. A. 2016;94:023832. doi: 10.1103/PhysRevA.94.023832. [DOI] [Google Scholar]
  • 10.Kumar, S., Fan, H., Kübler, H., Jahangiri, A. J. & Shaffer, J. P. Rydberg-atom based radio-frequency electrometry using frequency modulation spectroscopy in room temperature vapor cells. Preprint at, https://arxiv.org/abs/1702.00494 (2017). [DOI] [PubMed]
  • 11.Jiao, Y. et al. Atom-based radio-frequency field calibration and polarization measurement using cesium nDJ Floquet states. Preprint at https://arxiv.org/abs/1703.02286 (2017).
  • 12.Kanda M. Standard antennas for electromagnetic interference measurements and methods to calibrate them. Ieee Transactions on Electromagnetic Compatibility. 1994;36(4):261. doi: 10.1109/15.328855. [DOI] [Google Scholar]
  • 13.Kanda M. Standard probes for electromagnetic field measurements. Ieee transactions on antennas and propagation. 1993;41(10):1349. doi: 10.1109/8.247775. [DOI] [Google Scholar]
  • 14.Sriram, S. S., Kingsley, S. A. & Boyd, J. T. Electro-optical sensor for detecting electric fields, November 30. US Patent 5,267,336, https://patents.google.com/patent/US5267336 (1993).
  • 15.Pandey K, Rathod KD, Singh AK, Natarajan V. Atomic fountain of laser-cooled Yb atoms for precision measurements. Physical Review A. 2010;82:043429. doi: 10.1103/PhysRevA.82.043429. [DOI] [Google Scholar]
  • 16.Klinger E, et al. Magnetic field-induced modification of selection rules for Rb D2 line monitored by selective reflection from a vapor nanocell. European Physical Journal D. 2017;71(8):216. doi: 10.1140/epjd/e2017-80291-6. [DOI] [Google Scholar]
  • 17.Fan HQ, Kumar S, Daschner R, Kubler H, Shaffer JP. Subwavelength microwave electric-field imaging using Rydberg atoms inside atomic vapor cells. Optics Letters. 2014;39(10):3030. doi: 10.1364/OL.39.003030. [DOI] [PubMed] [Google Scholar]
  • 18.Höckel D, Scholz M, Benson O. A robust phase-locked diode laser system for EIT experiments in cesium. Applied Physics B. 2008;94:429. doi: 10.1007/s00340-008-3313-y. [DOI] [Google Scholar]
  • 19.King RJ, Yen YH. Probing amplitude, phase, and polarization of microwave field distributions in real time. IEEE Transactions on Microwave Theory and Techniques. 1981;29:1225–1231. doi: 10.1109/TMTT.1981.1130535. [DOI] [Google Scholar]
  • 20.Ivanov EN, Tobar ME, Woode RA. Microwave interferometry: application to precision measurements and noise reduction techniques. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 1998;45:1526–1536. doi: 10.1109/58.738292. [DOI] [PubMed] [Google Scholar]
  • 21.Ivanov EN, Tobar ME. Microwave phase detection at the level of 10−1 rad. Review of Scientific Instruments. 2009;80:044701. doi: 10.1063/1.3115206. [DOI] [PubMed] [Google Scholar]
  • 22.Mallick NS, Dey TN, Pandey K. Microwave assisted transparency in an M-system. J. Phys. B: At. Mol. Opt. Phys. 2017;50:195502. doi: 10.1088/1361-6455/aa8a35. [DOI] [Google Scholar]
  • 23.Pandey K. Role of different types of subsystems in a doubly driven Λ system in 87Rb. Phys. Rev. A. 2013;87:043838. doi: 10.1103/PhysRevA.87.043838. [DOI] [Google Scholar]
  • 24.Gea-Banacloche J, Li Y, Jin SZ, Xiao M. Electromagnetically induced transparency in ladder-type inhomogeneously broadened media: Theory and experiment. Phys. Rev. A. 1995;51:576–584. doi: 10.1103/PhysRevA.51.576. [DOI] [PubMed] [Google Scholar]
  • 25.Kwong CC, et al. Cooperative emission of a coherent superflash of light. Phys. Rev. Lett. 2014;113:223601. doi: 10.1103/PhysRevLett.113.223601. [DOI] [PubMed] [Google Scholar]
  • 26.Khan S, Bharti V, Natarajan V. Role of dressed-state interference in electromagnetically induced transparency. Physics Letters A. 2016;380:4100–4104. doi: 10.1016/j.physleta.2016.10.030. [DOI] [Google Scholar]
  • 27.Krishna A, Pandey K, Wasan A, Natarajan V. High-resolution hyperfine spectroscopy of excited states using electromagnetically induced transparency. EPL (Europhysics Letters). 2005;72:221–227. doi: 10.1209/epl/i2005-10228-6. [DOI] [Google Scholar]
  • 28.Mohapatra AK, Jackson TR, Adams CS. Coherent optical detection of highly excited Rydberg states using electromagnetically induced transparency. Phys. Rev. Lett. 2007;98:113003. doi: 10.1103/PhysRevLett.98.113003. [DOI] [PubMed] [Google Scholar]
  • 29.Pandey K, Wasan A, Natarajan V. Coherent control of magneto-optic rotation. Journal of Physics B: Atomic, Molecular and Optical Physics. 2008;41:225503. doi: 10.1088/0953-4075/41/22/225503. [DOI] [Google Scholar]
  • 30.Lee YS, Noh HR, Moon HS. Relationship between two- and three-photon coherence in a ladder-type atomic system. Opt. Express. 2015;23:2999–3009. doi: 10.1364/OE.23.002999. [DOI] [PubMed] [Google Scholar]
  • 31.Iftiquar SM, Natarajan V. Line narrowing of electromagnetically induced transparency in Rb with a longitudinal magnetic field. Phys. Rev. A. 2009;79:013808. doi: 10.1103/PhysRevA.79.013808. [DOI] [Google Scholar]
  • 32.Pandey K, Kwong CC, Pramod MS, Wilkowski D. Linear and nonlinear magneto-optical rotation on the narrow strontium intercombination line. Phys. Rev. A. 2016;93:053428. doi: 10.1103/PhysRevA.93.053428. [DOI] [Google Scholar]
  • 33.Wade, C. G. et al. Terahertz-driven phase transition applied as a room-temperature terahertz detector. Preprint at https://arxiv.org/abs/1709.00262 (2017).

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES