Abstract
Accurate quantitative analysis of image data requires that we distinguish between fluorescence intensity (true signal) and the noise inherent to its measurements to the extent possible. We image multilamellar membrane tubes and beads that grow from defects in the fluid lamellar phase of the lipid 1,2-dioleoyl-sn-glycero-3-phosphocholine dissolved in water and water-glycerol mixtures by using fluorescence confocal polarizing microscope. We quantify image noise and determine the noise statistics. Understanding the nature of image noise also helps in optimizing image processing to detect sub-optical features, which would otherwise remain hidden. We use an image-processing technique “optimum smoothening” to improve the signal-to-noise ratio of features of interest without smearing their structural details. A high SNR renders desired positional accuracy with which it is possible to resolve features of interest with width below optical resolution. Using optimum smoothening, the smallest and the largest core diameter detected is of width and nm, respectively, discussed in this paper. The image-processing and analysis techniques and the noise modeling discussed in this paper can be used for detailed morphological analysis of features down to sub-optical length scales that are obtained by any kind of fluorescence intensity imaging in the raster mode.
Electronic supplementary material
The online version of this article (10.1007/s00249-017-1273-z) contains supplementary material, which is available to authorized users.
Keywords: Image noise, Signal-to-noise ratio, Optimum smoothening, Tubules, Fluid lamellar phase
Introduction
Membrane tubes are found in cells connecting different membrane compartments (Lee and Chen 1988). Tubes are suggested to play an important role in vesicular transport pathways (Simunovic et al. 2016) and ultrafast endocytosis pathways (Boucrot et al. 2015; Renard et al. 2015) in cells. In general, tubes can either be composed of a single lipid bilayer (unilamellar tubes) of thickness nm or of many (multi-lamellar tubes, MLTs). In vitro experiments performed using the synthetic membrane compartments such as free-standing giant unilamellar vesicles (GUVs) demonstrate that unilamellar tubes can form spontaneously if the two leaflets of the bilayer face different chemical environments (Simunovic et al. 2015; Li et al. 2011; Dosti et al. 2017) or have compositional differences (Lipowsky 2013) and can also be pulled in/out by applying local mechanical forces (Rossier et al. 2003).
In this paper, we have discussed membrane tubes (Bhatia et al. 2015) of the lipid, 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) that grow from the defects in the multilamellar lipid reservoir hydrated in excess water. Figure 1a shows a fluorescence confocal polarizing microscope (FCPM) image of a tube with a central core filled with solvent having uniform core and outer diameter along the long-axis. Figure 1b, c show FCPM image of tubes with shape asymmetry, i.e., size of tube is varying (at regions I and II) along the tube’s long-axis (x-axis). The bead shown in Fig. 1c is a prolate-ellipsoidal structure, which appears on some tubes. We have found that near the neck of the beads, the inner core of the tubes is not blocked by lipid material, i.e., the inner core runs continuously through the tubes and the beads. However, the core radii of the tube and the bead are different. We have taken multiple confocal xyz scans of the tubes and have found that growth (or retraction) of tubes is considerably slowed down for a couple of days after the sample cell is sealed and no further morphological shape changes occur as described in a previous paper (Bhatia et al. 2015). Upon sealing of the sample cell tubes do not add on to or give away the lipid material to and from the lipid reservoir, and hence can be considered as quasi-static and structurally stable objects in osmotic equilibrium. The confocal xyz scans for the tubes shown in Fig. 1a–c are shown in the Movie1.avi, Movie2.avi, and Movie3.avi, respectively, in the Supplementary Materials. Figure 1d shows noise spread in the region () pixels of the image shown in Fig. 1a with a value between that is extracted from the image, as described in the Results section.
In this paper, we describe image-analysis techniques that are used to reduce noise inherent in the intensity measurements. Reducing the noise without affecting the signal helps to detect the shape parameters of MLTs such as core diameter, outer diameter, and lamella thickness with an accuracy down to nm. The image-processing and analysis techniques and the noise modeling discussed in this paper can be used for any kind of fluorescence image data obtained in the raster mode and is not limited to confocal images.
Methods
We have prepared lamellar stacks of the lipid DOPC (purchased from Sigma-Aldrich) onto a glass coverslip by spreading about 20–50 l of lipid solution in chloroform (containing about 0.2 mol% of the membrane dye, lissamine rhodamine B 1,2-dihexadecanoyl-sn-glycero-3-phosphoethanolamine, triethylammonium salt, RhPE purchased from Molecular Probes). The sample was gently dried under a nitrogen stream and kept covered inside a desiccator overnight with little vacuum sufficient to hold the chamber tight during the whole duration. A coated coverslip with dried sample was glued to a larger coverslip at the edges using mica spacers of about 100 m thickness. Solvent was introduced between the coverslips of sample cells by capillary action. The open edges were sealed using silicone glue immediately after the solvent filled the whole gap. We found that in the sealed sample cells, an osmotic equilibrium is reached between the swollen lamellar stack and excess water and the tubes remain stable for a couple of days. Sample cells are observed under a confocal microscope (LEICA TCS-SP2, He–Ne laser 543 nm) equipped with a 40 dry objective (0.85 N. A.) having a correction collar. Compared to a conventional microscope, the image contrast in the confocal microscope is improved by introducing two pinholes; (1) an excitation pinhole or illuminating aperture, and (2) an emission pinhole or confocal aperture. The first pinhole facilitates a point illumination of the tube by exciting fluorophores only in a small confocal volume defined by the axial () and in-plane point spread function (, ) of the microscope optics. The second pinhole allows a fluorescence signal only from the confocal volume to reach the detectors (Pawley 2006). The detector converts light intensity into a corresponding quantity of electric charge carriers. Such charge carriers are generated by the signal of interest with non-zero mean [] as well as due to random fluctuations in the signal intensity, namely noise with zero mean. Noise in general can be classified into three categories (Pawley 2006; Barlow 1999): (1) thermal noise, generated by system electronics, (2) Poisson noise, from random fluctuations in photon arrival time over a fixed period of time (given the mean) at the detector, and (3) dark noise, generated in the process of analog-to-digital conversion in the instrumentation and the random signal produced by photosensitive devices such as PMTs, photodiodes, or charge-coupled devices (CCDs) in the absence of any incident signal. A thin 2D planar optical-slice (or xy plane) of the tube is constructed by physically moving the focal spot with area () from one edge of the sample to the other end with a chosen spatial sampling interval or scanning pixel width (, ) and fixed confocal z-slice thickness (). In order to build a 3D image, the confocal objective is moved by a controlled step in the z-direction to image the next consecutive 2D optical slice. Having all the 2D optical slices and knowing the consecutive z-steps, a computer program is used to build a 3D image of the sample. We have experimentally measured the point spread function (PSF) of the microscope optics (, , ) for 40 objective by taking xyt and xyz scans of 200-nm isolated polystyrene fluorescent beads ( nm, nm) settled on the cover-slip in water (Sibarita 2005). We have analyzed ten fluorescence beads. From the Gaussian fit, we get m and m.
Positional accuracy
Rayleigh criterion considers only the limited numerical aperture of the objective to define resolution. Orhaug (1969), Falconi (1964), and Fried (1979) showed that the uncertainty in determining the position of a point source also depends on the signal-to-noise ratio (SNR ) and the spatial sampling interval. The positional uncertainty is defined by Downs and Reichley (1983).
1 |
where is the root mean square deviation of the noise and has the dimension of intensity, is the average intensity, is the intensity at kth point, with N points in the profile and is the spatial sampling interval at kth point. We have obtained confocal images of the narrow features with sampling interval finer than Nyquist sampling. The two length scales in the image have orders of magnitude difference that are associated with (1) the width of the feature of interest and (2) the pixel width or sampling interval . Given that () , it is possible to separate the Fourier components that correspond to the true signal (confined to lower spatial frequencies) and the random fluctuations in the true signal present in each pixel (confined to higher spatial frequencies). For an image having pixels (or data points) along y, if is the sampling width in the image domain, then corresponding sampling width in the Fourier domain is given by . We explore the possibility to improve the SNR of the feature based on the fact that the signal intensities are correlated over the length scale of the feature-width whereas random fluctuations in the observed intensities are not. We preferentially attenuate the noise in the higher spatial frequencies using suitable spatial frequency filter (low pass), amounting to smoothening in the image domain. We optimize the extent of smoothening operation for a particular feature of interest (e.g., one of the bright bands in the image) such that only noise is reduced without affecting the signal contribution. Let be the scale of smoothening in the image domain that corresponds to in the Fourier domain. For an image having pixels (or data points) along y, the scale of smoothening will be pixels in the image domain corresponding to spectral points in the Fourier domain. The low-pass filter used to smoothen our images is the 1-d double-Hann filter in Fourier domain shown in Fig. 2. This filter response smoothly goes to 0 at and beyond and is defined as
2 |
For discretizing the window function, we express the Fourier variable where . The function becomes
3 |
Results
The average intensity profile for tubes shown in Fig. 1 is given by , where is the number of rows averaged along x and is the number of frames. The intensity deviation from the mean at a pixel location (x, y) in a frame, gives the noise distribution across the image. Figure 3a shows the smoothened intensity profiles for m = (0.5 , ( and (1.5 on top of the raw intensity profile for the tube. We restrict our discussion to 1-D variation of the fluorescence intensity along y at fixed x. We estimate the variance of the fluctuations in fluorescence intensity, in the image. The red line in Fig. 3b shows the best model fit of the data (red color) with . The statistical distribution of noise contaminating the intensity measurement is completely defined by the variance [] and the mean []. We have (1) thermal noise for which is proportional to the observed mean square fluorescence intensity , (2) Poisson noise for which is proportional to the observed mean fluorescence intensity and (3) dark noise for which is independent of the signal intensity. From the fit shown in Fig. 3b we have and .
The SNR is defined as []. One of the bright bands in the image shown in Fig. 1a has a width with peak mean intensity at pixel number shown in Fig. 3a and [estimated using the relation between and ]. Thus, the peak SNR of this particular feature is . Noise can be reduced if and only if [] is decreased without affecting the ] giving a higher SNR. However, if [] is also decreased (by over-smoothening) together with [] then this eventually results in a decrease in SNR. To know precisely the value of the radius of smoothening (m) at which we do over-smoothening, we have scrutinized the fluorescence intensity profiles for different values of m on top of each other with the raw intensity profile () shown in Fig. 3a. To assess an optimum smoothening scale, we systematically vary trial values of the scale of the smoothening m and examine the resultant SNR shown in Fig. 3c for , where the PSF width in pixels is () for this image. As the radius of smoothening m is changed, the peak SNR of the feature is increased by 3.2 times from 53 up to 145 by smoothening operation. The magnitude of the SNR initially increases as we increase m, reaches a maximum at and then reduces. From Fig. 3a, we find that the peak intensity of the selected feature (at pixel number y = 156 shown in Fig. 3a) starts to come down for , and hence would be considered optimum for this feature, with SNR . Therefore, to retain the feature shape as intact as possible, we choose conservative smoothening, at the expense of (i.e., with less) SNR.
For the tube shown in Fig. 1b, we have performed the smoothening operation for the feature shown at cross section I and the result of smoothening operation is shown in Fig. 4. We compare the raw intensity profiles of the tube with the smoothened intensity profiles shown in the Fig. 4a for , (0.5 ), () and (1.5 ) where the PSF width in pixels is () for this image. The peak mean intensity is at pixel number shown in Fig. 4a. We estimate the variance of the fluctuations in fluorescence intensity in the image and the red line in Fig. 4b show the best model fit of the data with . From the fit, we have , and . We estimate the using the relation between and and this gives the peak SNR of this particular feature as . As shown in Fig. 4c, if we increase the smoothening radius (m) , the SNR initially increases, and reaches a maximum at and then starts to reduce slowly. We have improved the peak signal-to-noise ratio (SNR) of the feature by six times from up to 3000 by smoothening operation. From Fig. 4a we find that the peak intensity at pixel number and the knee intensity at pixel number and of the selected feature starts to come down for . Hence, would be considered optimum for this feature, with SNR .
For the tube shown in Fig. 1c, we have performed the smoothening operation for the feature shown at cross section I and the result of smoothening operation is shown in Fig. 5. We compare the raw intensity profiles of the tube with the smoothened intensity profiles shown in the Fig. 5a for (black), (0.5 (red), ( (green) and (1.5 (blue) where the PSF width in pixels is () for this image. The peak mean intensity is at pixel number shown in Fig. 5a. We estimate the variance of the fluctuations in fluorescence intensity in the image and the red line in Fig. 5b show the best model fit of the data with . From the fit, we have , and . We estimate the using the relation between and and this gives the peak SNR of this particular feature as . As shown in Fig. 5c, if we increase the smoothening radius (m) , the SNR initially increases, reaches a maximum at and then starts to reduce slowly. We have improved the peak SNR of the feature from up to 64 by smoothening operation. From Fig. 5a, we find that the peak intensity at of the selected feature starts to come down for . Hence would be considered optimum for this feature, with SNR .
Advantage of optimum smoothening in the model fitting
We retain the images with their original sampling, which offers advantage at the model fitting stage as described below. For a given cross section of tube at x, the best fits are obtained by minimizing the weighted given by Bevington and Robinson (2002)
4 |
where is the smoothened intensity profile chosen optimally, is the model intensity profile, is a scaling parameter required for the fit of with , is the standard deviation of the noise associated with pixel along the y-axis for a given x (calculated from noise modeling), and k labels separate concentric tubes in a given cross section. The number of pixels (j) are kept the same as originally chosen for image scanning, even though the intensity profile is smoothened with optimally chosen spatial smoothening scale. The model for the tubes to obtain the in Eq. (4) is discussed in detail previously (Bhatia et al. 2015). We model the two halves (divided by the xz plane) separately to estimate the fitting parameters because for asymmetric tubes (shown in Fig. 1b), the axis of shape asymmetry need not be same as the central axis of the tube.
We first consider the simple tube Fig. 1a. The folded left and right halves of the tube are plotted on top of each other, as shown in Fig. 6a, after finding the symmetry axis by cross correlation. We find that the tube consists of a single core. The best fit of the smoothened intensity profile for with the model intensity profile is shown in Fig. 6b. The error bars on the smoothened intensity profile are calculated from noise statistics [] at each pixel. From the best fit, we find: = and .
Figure 6c shows the folded left and right halves of the cross section labeled II of the tube shown in Fig. 1b. For the best fit of the smoothened intensity profile for with the model intensity profile, this region requires three values of k, i.e., three separate tubes where the radii of various regions are denoted by , , etc., as described in Eq. (4). From the best fit, we find that the cross section II consists of three tubes with shape parameters: , , = ((0.044, 0.92), (1.03, 1.69), , and . We plot the values of the fit for the core diameter (2rc1) shown in Fig. 6d, where we vary the innermost core size from 0.046 to 0.16 in the steps of 4–23 nm shown in the inset of Fig. 6d. We find that the values for or for higher core size and or for lower core size up to 46 nm (two pixels). The innermost core size, as decided by the minimum , is (46–88) nm with a sensitivity of ± 23 nm (one pixel) for the image shown in Fig. 1b. It is important to emphasize that it is possible to extract core sizes as small as 46–88 nm with a sensitivity of ± 23 nm (one pixel) as a result of optimum smoothening (shown in Fig. 4a) for , which would otherwise remain hidden under the noise. For the tube shown in Fig. 1c, the shape parameters are provided in a previous paper (Bhatia et al. 2015).
Conclusions
The image-processing, analysis techniques and the noise modeling discussed in this paper can be used for extracting the structural parameters of objects with features width at sub-optical and at or above optical length scales. The procedure is demonstrated by three different examples of tubes, as shown in Fig. 1. The image-processing procedure, “optimum smoothening”, has the potential to reduce the noise inherent to the intensity measurements during image formation without affecting the true signal. The SNR is defined as []. Noise is reduced if and only if [] is decreased without affecting the [] giving a higher SNR, as shown in Figs. 3c, 4c, and 5c for . However, if data is over-smoothened, then [] is also decreased together with [] and this eventually results in a decrease in SNR. To know precisely the optimum value of the radius of smoothening (m) beyond which we start to lose [, we have scrutinized the fluorescence intensity profiles for different values of m on top of each other with the raw intensity profile () shown in Figs. 3a, 4a, and 5a. As the radius of smoothening, m, is changed in the half-integral values of the PSF width from 0.5 to 1.5, the value of the peak intensity at pixel number (in Fig. 3a) starts to come down for . Similar behavior is seen in Fig. 4a at (knee intensity), (peak intensity) and 330 (knee intensity) and in Fig. 5a at (peak intensity). We have chosen an optimum value of m such that only random fluctuations are smoothened (noise is reduced) without affecting the peak or the knee intensity (true signal) shown in Figs. 3a, 4a, and 5a.
We have shown that optimum smoothening can be used to increase SNR. This helps in detecting the innermost core size of 46–88 nm with a sensitivity of ± 23 nm (one pixel), which would otherwise remain hidden in the noise. The only requirement for the imaging method is that it should be in the raster mode (pixel by pixel). The choice can be either standard confocal or super-resolution microscopes depending on the samples. In both cases, as long as we have separation of length scales in the images with feature width much larger than the sampling interval, it is possible to separate out the Fourier components of the noise and the true signal. The random noise associated with each pixel cannot be avoided but can be minimized by using a low-pass filter, such as a 1-D double Hann filter. The choice of low-pass filter may vary from sample to sample depending on the nature and dynamics of the feature of interest. We choose the 1-D double Hann filter because in the image domain, the associated smoothening function of has lower side-lobe levels. This reduces the possible “ringing” effect in the image. The method described here can be used to extract shape parameters of features such as membrane tubes (or beads) that are reported previously (Simunovic et al. 2015, 2016; Boucrot et al. 2015; Renard et al. 2015; Domanov and Kinnunen 2006; Domingues and Miranda 2010; Arouni et al. 2011; Stossel and Hartwig 2006; Virchow 1854; Chapman and Fluck 1966; Sandermann and Vatter 1977; Sakurai and Sakurai 1989; Zou and Nagel 2006; Zou 2009; Huang et al. 2005). The choice of membrane dye is arbitrary because it is possible to find out independently the orientation of the dye in the lipid bilayer to model the intensity profiles.
With oversampling in our images at sampling frequency much larger than the Fourier components corresponding to the signal, we have explored the possibility of optimum smoothening in the image domain. Finding the statistics of the image noise, i.e., the relation between and is helpful to model the noise, which is used to extract and reduce the random fluctuations in the signal intensity at each pixel in the image. By understanding the nature of the noise, we try to optimize the image processing by optimizing the scale of smoothening in order to increase the SNR for a feature of interest. The results from application of this method are used for further modeling the structure of the tubes and beads of a common well-hydrated phospholipid DOPC in the phase. We find that almost all tubes have a core, with a few tubes having a core diameter below the optical resolving limit. We could detect features of size as small as nm by enhancing the SNR using optimum smoothening without deconvolution.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Acknowledgements
Open access funding provided by Max Planck Society. TB acknowledges Ph.D. thesis research fellowship from the Raman Research Institute (RRI), Bangalore, India. TB acknowledges Prof. Yashodhan Hatwalne (RRI), Prof. A. A. Deshpande (RRI), and Prof. N. V. Madhusudana (INSA Scientist, RRI) for useful discussions.
Footnotes
Electronic supplementary material
The online version of this article (10.1007/s00249-017-1273-z) contains supplementary material, which is available to authorized users.
References
- Arouni A, Kiessling V, Tamm L, Dathe M, Blume A. Morphological changes induced by the action of antimicrobial peptides on supported lipid bilayers. J Phys Chem B. 2011;115:158. doi: 10.1021/jp107577k. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Barlow RJ. Statistics: a guide to the use of statistical methods in the physical sciences. New York: Wiley; 1999. [Google Scholar]
- Bevington PR, Robinson DK. Data reduction and error analysis for the physical sciences. Boston: McGraw-Hill; 2002. [Google Scholar]
- Bhatia T, Hatwalne Y, Madhusudana NV. Tubular growth and bead formation in the lyotropic lamellar phase of a lipid. Soft Matter. 2015;11:5641–5646. doi: 10.1039/C5SM00793C. [DOI] [PubMed] [Google Scholar]
- Boucrot E, Ferreira AP, Almeida-Souza L, Debard S, Vallis Y, Howard G, Bertot L, Sauvonnet N, McMahon HT. Endophilin marks and controls a clathrin-independent endocytic pathway. Nature. 2015;517:460–465. doi: 10.1038/nature14067. [DOI] [PubMed] [Google Scholar]
- Chapman D, Fluck DJ. Physical studies of phospholipids. J Cell Biol. 1966;30:1. doi: 10.1083/jcb.30.1.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Domanov YA, Kinnunen PKJ. Antimicrobial peptides temporins B and L induce formation of tubular lipid protrusions from supported phospholipid bilayers. Biophys J. 2006;91:4427. doi: 10.1529/biophysj.106.091702. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Domingues TM, Riske KA, Miranda A. Revealing the lytic mechanism of the antimicrobial peptide gomesin by observing giant unilamellar vesicles. Langumir. 2010;26:11077. doi: 10.1021/la100662a. [DOI] [PubMed] [Google Scholar]
- Dosti BA, Pezeshkian W, Bruhn DS, Ipsen JH, Khandelia H, Jeffries GDM, Lobovkina T. Membrane tubulation in lipid vesicles triggered by the local application of calcium ions. Langmuir. 2017;33:11010–11017. doi: 10.1021/acs.langmuir.7b01461. [DOI] [PubMed] [Google Scholar]
- Downs GS, Reichley PE (1983) JPL pulsar timing observations. II: geocentric arrival times. Astrophys J Suppl Ser 53:169
- Falconi O. Maximum sensitivities of optical direction and twist measuring instruments. J Opt Soc Am. 1964;54:131. doi: 10.1364/JOSA.54.001315. [DOI] [Google Scholar]
- Fried DL. Resolution, signal-to-noise ratio, and measurement precision. J Opt Soc Am. 1979;69:399–406. doi: 10.1364/JOSA.69.000399. [DOI] [Google Scholar]
- Huang JR, Zou LN, Witten TA. Confined multilamellae prefer cylindrical morphology. Eur Phys J E. 2005;18:279. doi: 10.1140/epje/e2005-00035-8. [DOI] [PubMed] [Google Scholar]
- Lee C, Chen LB. Dynamic behavior of endoplasmic reticulum in living cells. Cell. 1988;54:37–46. doi: 10.1016/0092-8674(88)90177-8. [DOI] [PubMed] [Google Scholar]
- Li Y, Lipowsky R, Dimova R. Membrane nanotubes induced by aqueous phase separation and stabilized by spontaneous curvature. Proc Natl Acad Sci USA. 2011;108:4731. doi: 10.1073/pnas.1015892108. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lipowsky R. Spontaneous tubulation of membranes and vesicles reveals membrane tension generated by spontaneous curvature. Faraday Discuss. 2013;161:305. doi: 10.1039/C2FD20105D. [DOI] [PubMed] [Google Scholar]
- Orhaug T. On the resolution of imaging systems. Optica Acta. 1969;16:75–84. doi: 10.1080/713818155. [DOI] [Google Scholar]
- Pawley J. Handbook of biological confocal microscopy. 3. Berlin: Springer; 2006. [Google Scholar]
- Renard HF, Simunovic M, Lemire J, Boucrot E, Garcia-Castillo MD, Arumugam S, Chambon V, Lamaze C, Wunder C, Kenworthy A, Schmidt A, McMahon HT, Sykes C, Bassereau P, Johannes L. Endophilin-A2 functions in membrane scission in clathrin-independent endocytosis. Nature. 2015;517:493–496. doi: 10.1038/nature14064. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rossier O, Cuvelier D, Borghi N, Puech PH, Derenyi I, Buguin A, Nassoy P, Brochard-Wyart F. Giant vesicles under flows: extrusion and retraction of tubes. Langmuir. 2003;19:575–584. doi: 10.1021/la026236t. [DOI] [Google Scholar]
- Sakurai I, Suzuki T, Sakurai S. Cross-sectional view of myelin figures. Biochim Biophys Acta. 1989;985:101. doi: 10.1016/0005-2736(89)90110-7. [DOI] [Google Scholar]
- Sandermann RJ, Vatter AE. Mode of formation of tubular myelin from lamellar bodies in lung. Journal of Cell Biology. 1977;74:1027–1031. doi: 10.1083/jcb.74.3.1027. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sibarita JB. Microscopy techniques. Berlin: Springer; 2005. pp. 201–243. [Google Scholar]
- Simunovic M, Lee KYC, Bassereau P. Celebrating Soft Matter’s 10th anniversary: screening of the calcium-induced spontaneous curvature of lipid membranes. Soft Matter. 2015;11:5030. doi: 10.1039/C5SM00104H. [DOI] [PubMed] [Google Scholar]
- Simunovic M, Prevost C, Callan-Jones A, Bassereau P. Physical basis of some membrane shaping mechanisms. Philos Trans R Soc. 2016;374:20160034. doi: 10.1098/rsta.2016.0034. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stossel TP, Fenteany G, Hartwig JH. Cell surface actin remodeling. J Cell Sci. 2006;119:3261. doi: 10.1242/jcs.02994. [DOI] [PubMed] [Google Scholar]
- Virchow R. Ueber das ausgebreitete Vorkommen einer dem Nervenmark analogen Substanz in den tierischen Gewebe. Virchows Arch. 1854;6:562. doi: 10.1007/BF02116709. [DOI] [Google Scholar]
- Zou LN. Myelin figures: the buckling and flow of wet soap. Phys Rev E. 2009;79:061502. doi: 10.1103/PhysRevE.79.061502. [DOI] [PubMed] [Google Scholar]
- Zou LN, Nagel SR. On the stability and growth of single myelin figures. Phys Rev Lett. 2006;96:138301. doi: 10.1103/PhysRevLett.96.138301. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.