Correction
-
On page 4 of the original publication [1], the correct sentence should read:
Quantitative measurement was performed by dissolving CV stained pellicle in 4 ml of 85% ethanol and the OD570 was measured using microplate reader at 200 μl per well.
Table 2 of this original publication contained some errors. The updated Table 2 is published in this correction article.
Table 2.
Pathotypes | Isolates No. | Biofilm mass on polystyrene at incubation time of | Biofilm mass onb | Pellicle formationc | |||
---|---|---|---|---|---|---|---|
24 h | 48 h | 72 h | SS | GS | |||
EHEC | EC1A | 0.024 ± 0.004a | 0.076 ± 0.015 | 0.049 ± 0.007 | 1 | 1 | 0.061 ± 0.011 |
EC1113B | 0.029 ± 0.005 | 0.119 ± 0.022 | 0.191 ± 0.039 | 3 | 3 | 1.884 ± 0.259 | |
EC1643B | 0.047 ± 0.006 | 0.251 ± 0.033 | 1.126 ± 0.153 | 3 | 3 | 3.595 ± 0.191 | |
EC1857 | 0.036 ± 0.006 | 0.063 ± 0.011 | 0.107 ± 0.016 | 3 | 3 | 0.856 ± 0.078 | |
EC217 | 0.054 ± 0.009 | 0.100 ± 0.015 | 0.043 ± 0.008 | 2 | 1 | 0.025 ± 0.009 | |
EC3455 | 0.066 ± 0.008 | 0.025 ± 0.005 | 0.060 ± 0.007 | 3 | 3 | 1.228 ± 0.145 | |
EC3522 | 0.060 ± 0.008 | 0.058 ± 0.010 | 0.086 ± 0.011 | 1 | 1 | 0.039 ± 0.034 | |
EC3547A | 0.043 ± 0.003 | 0.236 ± 0.014 | 0.503 ± 0.030 | 2 | 2 | 0.839 ± 0.113 | |
EC3652B | 0.056 ± 0.010 | 0.102 ± 0.014 | 0.104 ± 0.016 | 3 | 3 | 1.875 ± 0.103 | |
EC3659B | 0.026 ± 0.009 | 0.058 ± 0.009 | 0.093 ± 0.014 | 3 | 3 | 1.652 ± 0.152 | |
EC3671A | 0.016 ± 0.005 | 0.091 ± 0.010 | 0.125 ± 0.017 | 3 | 3 | 1.554 ± 0.167 | |
EC3738B | −0.010 ± 0.003 | 0.032 ± 0.013 | 0.093 ± 0.027 | 1 | 1 | 0.145 ± 0.030 | |
EC3743A | 0.038 ± 0.006 | 0.087 ± 0.011 | 0.075 ± 0.010 | 3 | 3 | 1.218 ± 0.087 | |
EC4 | 0.023 ± 0.004 | 0.045 ± 0.009 | 0.024 ± 0.005 | 2 | 1 | 0.097 ± 0.023 | |
EC478B | 0.086 ± 0.011 | 0.127 ± 0.011 | 0.133 ± 0.011 | 2 | 2 | 0.480 ± 0.061 | |
EC674 | 0.011 ± 0.005 | 0.064 ± 0.013 | 0.130 ± 0.023 | 3 | 3 | 1.660 ± 0.151 | |
EC7B | 0.082 ± 0.014 | 0.109 ± 0.013 | 0.230 ± 0.052 | 3 | 3 | 1.397 ± 0.091 | |
EC4158QH1 | 0.047 ± 0.005 | 0.082 ± 0.015 | 0.069 ± 0.011 | 1 | 1 | 0.092 ± 0.042 | |
EC4159QH2 | 0.049 ± 0.007 | 0.089 ± 0.013 | 0.055 ± 0.007 | 2 | 1 | 0.035 ± 0.025 | |
EC4160QH3 | 0.098 ± 0.015 | 0.034 ± 0.008 | 0.044 ± 0.008 | 2 | 3 | 2.257 ± 0.099 | |
EC3213QH34 | 0.036 ± 0.006 | 0.072 ± 0.007 | 0.171 ± 0.017 | 3 | 3 | 1.079 ± 0.046 | |
EC4161QH4 | 0.075 ± 0.012 | 0.060 ± 0.010 | 0.061 ± 0.009 | 2 | 1 | 0.050 ± 0.021 | |
EC4162QH5 | 0.001 ± 0.009 | 0.088 ± 0.020 | 1.021 ± 0.154 | 3 | 3 | 2.882 ± 0.255 | |
EC4163QH6 | 0.017 ± 0.003 | 0.135 ± 0.030 | 1.469 ± 0.304 | 2 | 3 | 1.848 ± 0.127 | |
EC4164QH7 | 0.053 ± 0.006 | 0.223 ± 0.025 | 0.245 ± 0.025 | 2 | 1 | 0.092 ± 0.034 | |
EC4165QH8 | 0.070 ± 0.008 | 0.127 ± 0.019 | 0.156 ± 0.026 | 1 | 1 | 0.065 ± 0.037 | |
EC4166QH9 | 0.061 ± 0.007 | 0.051 ± 0.010 | 0.070 ± 0.010 | 3 | 3 | 2.746 ± 0.163 | |
pEHEC | EC801 | 0.040 ± 0.005 | 0.119 ± 0.017 | 0.121 ± 0.020 | 2 | 1 | 0.150 ± 0.042 |
EC3983A | 0.033 ± 0.006 | 0.057 ± 0.011 | 0.074 ± 0.010 | 2 | 1 | 0.081 ± 0.024 | |
EC3989A | 0.063 ± 0.008 | 0.638 ± 0.036 | 1.402 ± 0.203 | 3 | 3 | 3.859 ± 0.138 | |
aEPEC | EC3435A | 0.044 ± 0.009 | 0.041 ± 0.007 | 0.060 ± 0.007 | 0 | 1 | 0.104 ± 0.064 |
EC3457 | 0.110 ± 0.020 | 0.134 ± 0.023 | 0.135 ± 0.014 | 1 | 1 | −0.001 ± 0.030 | |
EC3610A | 0.019 ± 0.003 | 0.017 ± 0.004 | 0.033 ± 0.005 | 1 | 0 | 0.018 ± 0.023 | |
EC3727A | 0.037 ± 0.005 | 0.034 ± 0.007 | 0.119 ± 0.021 | 0 | 1 | 0.268 ± 0.051 | |
EC3735A | 0.046 ± 0.011 | 0.017 ± 0.011 | 0.108 ± 0.019 | 0 | 1 | 0.135 ± 0.027 | |
EC3768A | 0.035 ± 0.012 | 0.078 ± 0.017 | 0.206 ± 0.028 | 0 | 1 | 0.128 ± 0.020 | |
EC4013A | 0.048 ± 0.018 | 0.027 ± 0.011 | 0.101 ± 0.014 | 0 | 1 | 0.177 ± 0.032 | |
EC4039A | 0.006 ± 0.003 | 0.060 ± 0.009 | 0.048 ± 0.007 | 1 | 0 | −0.005 ± 0.013 | |
NTEC | EC3536B | 0.052 ± 0.005 | 0.224 ± 0.021 | 0.475 ± 0.034 | 3 | 3 | 0.966 ± 0.158 |
EC3946A | 0.052 ± 0.006 | 0.313 ± 0.056 | 0.404 ± 0.034 | 3 | 3 | 0.587 ± 0.127 | |
Negative control | Lb broth | 0.080 ± 0.0009 | 0.078 ± 0.001 | 0.071 ± 0.0004 | 0 | 0 |
aValues are shown as mean of biofilm production ± standard error on polystyrene surfaces, SS: stainless steel, GS: glass slide at 25 °C. According to the biofilm
mass quantified with crystal violet staining assay at 570 nm isolates were labelled as the following: low, medium and thick biofilm formers
bVisible biofilms on stainless steel and glass slides and was scored as 0: no visible biofilm, scored on a scale from 1 to 3 to a thick biofilm at the air-liquid
cThe presence and absence of visible pellicles biofilms was scored visually before staining with CV. Strains with visible pellicles at the air-liquid interface had OD570 ≥0.48
Footnotes
The original article can be found online at 10.1186/s12866-018-1182-z
Reference
- 1.Lajhar SA, et al. Characterization of biofilm-forming capacity and resistance to sanitizers of a range of E.coli O26 pathotypes from clinical cases and cattle in Australia. BMC Microbiol. 2018;18:41. doi: 10.1186/s12866-018-1182-z. [DOI] [PMC free article] [PubMed] [Google Scholar]