Skip to main content
. 2018 Apr 11;23(4):882. doi: 10.3390/molecules23040882

Table 1.

The effect of longitudinal averaging, isotropic Gaussian filter, seven-peak 2D convolution, and one-peak 2D convolution on overall accuracy.

Row Implementation Avg_L a Gauss b 7 Peaks c 1 Peak d AvgError e
1 Trace_L_G_7 1.300
2 Trace_L_7 1.345
3 Trace_G_7 1.523
4 Trace_L_1 2.157
5 Trace_L_G_1 2.420
Improvement in the seven-peak convolution f 46.28%
Improvement in the longitudinal average g 14.62%

a Longitudinal average along the direction of the bundle; b isotropic Gaussian filter applied to the original density map; 2D convolution using c seven Gaussian peaks and d one Gaussian peak; e average cross-distance (in voxels) between the manually and computationally detected 330 filaments. A check mark indicates that a technique in the column was applied. For example, 1.300 voxels was the average cross-distance when the longitudinal average, isotropic Gaussian filter and seven-peak convolution were applied. f Improvement = difference in error between row 5 and row 1/error in row 5; g improvement = difference in error between row 3 and row 1/error in row 3.