Skip to main content
Oxidative Medicine and Cellular Longevity logoLink to Oxidative Medicine and Cellular Longevity
. 2018 Jun 14;2018:3714725. doi: 10.1155/2018/3714725

Exposure to Ti4Al4V Titanium Alloy Leads to Redox Abnormalities, Oxidative Stress, and Oxidative Damage in Patients Treated for Mandible Fractures

Jan Borys 1, Mateusz Maciejczyk 2,, Bożena Antonowicz 3, Adam Krętowski 4, Danuta Waszkiel 5, Piotr Bortnik 1, Katarzyna Czarniecka-Bargłowska 1, Magdalena Kocisz 5, Julita Szulimowska 6, Marek Czajkowski 7, Napoleon Waszkiewicz 8, Anna Zalewska 5
PMCID: PMC6022263  PMID: 30013720

Abstract

Due to the high biotolerance, favourable mechanical properties, and osseointegration ability, titanium is the basic biomaterial used in maxillofacial surgery. The passive layer of titanium dioxide on the surface of the implant effectively provides anticorrosive properties, but it can be damaged, resulting in the release of titanium ions to the surrounding tissues. The aim of our work was to evaluate the influence of Ti6Al4V titanium alloy on redox balance and oxidative damage in the periosteum surrounding the titanium miniplates and screws as well as in plasma and erythrocytes of patients with mandibular fractures. The study included 31 previously implanted patients (aged 21–29) treated for mandibular fractures and 31 healthy controls. We have demonstrated increased activity/concentration of antioxidants both in the mandibular periosteum and plasma/erythrocytes of patients with titanium mandibular fixations. However, increased concentrations of the products of oxidative protein and lipid modifications were only observed in the periosteum of the study group patients. The correlation between the products of oxidative modification of the mandible and antioxidants in plasma/erythrocytes suggests a relationship between the increase of oxidative damage at the implantation site and central redox disorders in patients with titanium miniplates and screws.

1. Introduction

Jaw bone fractures are a frequent and significant problem in clinical practice. The most common types of injuries are mandibular fractures that lead to morphological and functional disorders of the stomatognathic system as well as aesthetic defects of the facial skeleton. The treatment of mandibular fractures is aimed at reconstructing the anatomical shape of the bones and occlusion from before the injury and restoring normal functions of the chewing organ and facial aesthetics [1]. The use of internal bone fixation systems with miniplates and screws allows not only to avoid long-term intermaxillary immobilization and dental splint insertion, which are troublesome for the patient, but also to cure fractures in case of contraindications for inoperative orthopaedic treatment [1]. Miniplates and screws made of titanium, due to the high biocompatibility of this metal and its alloys used in the production of such fixations, are commonly used in traumatology, maxillofacial oncology, and orthognathic surgery. Despite the undoubted advantages of titanium bone fixations, their negative impact on the human body, both at the implant site and at the systemic level, is still debated [1, 2]. During the removal of titanium bone fixations, the presence of discoloured gray tissues surrounding the miniplates and screws was often observed [3, 4]. Some patients have also suffered from inflammatory symptoms around the anastomosis sites reported postoperatively both after several months and even years after osteosynthesis of the fractured mandible. Therefore, it is important to explore the impact of titanium miniplates and screws on the surrounding tissues [2]. The results of recent studies indicate that the cause of chronic inflammation around titanium bone fixations may be the increased production of oxygen-free radicals and reactive nitrogen species (RNS) [3, 57]. It is believed that overproduction of reactive oxygen species (ROS) and RNS can lead to the damage of cellular components by oxidation, thereby impairing normal cell functioning as a result of increased synthesis of proinflammatory mediators and affecting growth, differentiation, and apoptosis processes in the cells [8].

Although oxidative stress is one of the mechanisms of titanium toxicity [9], the kind (and extent) of oxidative damage it can cause is still unknown. What is more, the literature on the subject so far has not offered any study evaluating the effect of titanium bone fixation systems in patients with mandibular fractures on the redox balance both at the implant site and at the systemic level. Therefore, the aim of our work was to evaluate enzymatic and nonenzymatic antioxidant systems and oxidative damage of proteins, lipids, and DNA in the periosteum surrounding the bone fixations as well as in plasma and erythrocytes of patients treated for mandible fractures, compared to the control group.

2. Materials and Methods

2.1. Patients

The protocol of the study was approved by the Bioethics Committee of the Medical University of Bialystok, Poland (permission number R-I-002/3/2-16).

62 patients operated at the Department of Maxillofacial and Plastic Surgery, Medical University in Bialystok, Poland, were enrolled in the study. The study group included 31 previously implanted patients (11 women and 20 men aged 21–29, mean age: 24 years and 7 months) treated for mandibular fractures. The causes of the fractures in patients were beating (61.2%), sports (19.4%), traffic accident (12.9%), and fall from the stairs (6.5%). All patients were treated for bilateral fracture of the mandibular body. The fractured bone fragments in the mandible were fixed with two 4- or 6-hole miniplates and 4–6 screws (on the right and left side): in total 4 miniplates and 16–24 screws (MEDGAL Sp. z o.o., Księżyno, Poland).

Two months after implantation (every 2 weeks), and then, every month until the fixations were removed, the patients went to the hospital for follow-up examinations performed by one qualified surgeon (J.B.). In all patients from the study group, there were no signs of acute and chronic inflammation such as edema, inflammatory infiltration, purulent fistula, and redness of the mucous membrane or skin around the titanium fixations. In the physical examination, no enlargement of regional lymph nodes was also observed, which did not require specialized diagnostics in these group of patients. In the study group, there were also no clinical allergy signs like edema, changes on the skin, and mucous membranes.

The control group, selected by sex and age to match the study group, consisted of 31 generally healthy patients (11 women and 20 men aged 21–29, mean age: 24 years and 2 months) operated due to dentofacial deformities, whose periosteum and blood samples were taken immediately prior to the insertion of titanium implants.

2.1.1. Inclusion Criteria: Study Group

  1. Maxillary bone fixations after treatment for fractures of the mandibular body.

2.1.2. Inclusion Criteria: Control Group

  1. Generally healthy patients with dentofacial deformities before surgical treatment.

2.1.3. Inclusion Criteria: Study and Control Group

  1. Written informed consent for participation in the study,

  2. Age 21–29,

  3. 18.5 ≤ BMI ≥ 24.5,

  4. No former treatment for bone fracture or jaw osteotomies performed with titanium fixations,

  5. A noninflammation-induced healing process from insertion of fixations until their removal,

  6. No craniocerebral traumas (hematomas),

  7. Normal results of complete blood count (WBC 4.5–8.5 ×103/μL; RBC 3.6–5.4 ×1012/L; HGB 12.0–16.0 g/dL; PLT 100–450 ×109/L; hematocrit 36–54%) and biochemical blood tests (CRP 0.1–5 mg/L; Na+ 135.0–145.0 mmol/L; K+ 3.8–5.0 mmol/L; international normalized ratio (INR), 0.9–1.3; activated partial thromboplastin time (APTT), 37.0–46.0 sec; prothrombin time (PT), 12.0–18.0 sec),

  8. No systemic (insulin resistance, diabetes, hypertension, and coronary heart disease) and autoimmune disorders (psoriasis, multiple sclerosis, and rheumatoid arthritis), hyperlipidemia, liver, kidney, thyroid, lung, gastrointestinal and infectious (HCV and HIV infection) diseases, or gingivitis, periodontitis, and active odontogenic infection foci,

  9. Nonsmokers,

  10. Nonalcohol drinkers,

  11. No intake of antibiotics, nonsteroidal anti-inflammatory drugs (NSAIDs), glucocorticosteroids, dietary supplements, and vitamins.

2.1.4. Exclusion Criteria: Study and Control Group

  1. Another type of mandibular fracture (singular fracture, fracture of mandibular ramus or condyle),

  2. Wounds of soft tissues, injury of the skull, brain, chest, abdomen, and extremities,

  3. Inflammatory complications and jaw synostosis disorders after implantation,

  4. Operations due to bone fractures in the past and for other reasons during the last year.

The clinical parameters of patients and control group are presented in Table 1.

Table 1.

Clinical characteristics of patients with titanium mandibular fixations and healthy controls.

Serum/plasma Control group Study group
Mean SD Geometric mean Lower 95% CI of mean Upper 95% CI of mean Mean SD Geometric mean Lower 95% CI of mean Upper 95% CI of mean
WBC ×103/μL 7.530 1.958 7.278 6.841 8.219 6.917 1.709 6.756 6.315 13.232
RBC ×106/μL 5.207 0.411 5.193 5.062 5.352 5.070 0.264 5.064 4.977 10.047
HGB g/dL 15.270 1.027 15.240 14.908 15.632 15.320 0.720 15.300 15.067 30.387
HCT % 45.230 2.630 45.160 44.304 46.156 45.550 2.123 45.510 44.803 90.353
MCV fL 87.140 3.817 87.070 85.796 88.484 89.630 3.549 89.570 88.381 178.011
MCHC g/dL 33.760 0.918 33.750 33.437 34.083 33.650 1.524 33.620 33.114 66.764
PLT ×103/μL 230.700 43.800 227.100 215.282 246.118 228.300 23.380 227.300 220.070 448.370
PT s 12.230 0.624 12.220 12.010 12.450 11.660 0.699 11.640 11.414 23.074
INR 0.935 0.077 0.933 0.908 0.962 0.908 0.072 0.906 0.883 1.791
APTT s 27.640 1.468 27.610 27.123 28.157 26.780 3.809 26.550 25.439 52.219
Na+ mmol/L 140.700 1.890 140.700 140.035 141.365 139.800 1.184 139.800 139.383 279.183
K+ mmol/L 4.363 0.317 4.353 4.251 4.475 4.390 0.215 4.386 4.314 8.704
CRP mg/L 1.050 0.370 1.002 0.920 1.180 1.000 0.548 0.880 0.807 1.807

Statistical significance p < 0.05, study group versus control.

2.2. Surgical Procedure

All patients were operated by the same qualified maxillofacial surgeon (J.B.). Two months before the surgery, patients in both groups were on a diet (2000 kcal, including 55% carbohydrates, 30% fat, and 15% protein) determined by a dietician. Miniplates and screws were removed under local anaesthesia of 2% lignocaine and epinephrine (Polfa, Warsaw, Poland) from 3 to 8 months (approx. 5 months) after the surgery. The research material was a gray-pigmented periosteum adhering to the titanium miniplates excised as a standard procedure during the removal of mandibular bone fixations. In the control group, healthy periosteum was taken separately from the mandible during bimaxillary osteotomy before implantation of the miniplates and screws. Gray-pigmented periosteum was aseptic (data not shown). The tissues were immediately frozen upon collection in liquid nitrogen and stored at −80°C until assayed.

2.3. Blood (Plasma and Erythrocytes)

Before the surgery and after an overnight fast, 9 mL of venous blood samples were collected in plastic EDTA tubes (S-Monovette® K3 EDTA blood collection system, Sarstedt). To separate plasma samples and erythrocytes, the samples were centrifuged at 1500 ×g (4°C, 10 min; MPW 351, MPW Med. Instruments, Warsaw, Poland). Erythrocytes were washed three times in cold solution of 0.9% NaCl (w : v) and haemolysed by the addition of cold 50 mM phosphate buffer (pH 7.4) 1 : 9 (v : v) [10]. In order to prevent sample oxidation, 0.5 M butylated hydroxytoluene (Sigma-Aldrich, Germany; 100 μL/10 mL sample) was added [11]. All samples were stored at –80°C until use.

2.4. Tissue Homogenates

Before the biochemical determinations, fragments of periosteum were rinsed in ice-cold PBS (20 mM, pH 7.0), weighed and milled into small pieces that were homogenized on ice (Omni TH, Omni International, Kennesaw, GA, USA) in ice-cold PBS (1 : 15, w : v). 0.5 M butylated hydroxytoluene (10 μL/1 mL PBS) and the protease inhibitor (Complete Mini Roche, France; 1 tablet/10 mL PBS) were added to all the samples [12]. The tissue suspensions were sonicated on ice with an ultrasonic cell disrupter (UP 400S, Hielscher, Teltow, Germany; 1800 J/sample, 20 s x 3) and centrifuged (3500 ×g, 4°C, 20 min), and the resulting supernatants were analyzed on the same day.

2.5. Antioxidant Assays

Antioxidant enzymes (glutathione peroxidase (GPx), catalase (CAT), and superoxide dismutase-1 (SOD)) and total protein were analyzed in erythrocytes and tissue homogenates, while nonenzymatic antioxidants (reduced glutathione (GSH) and uric acid (UA)) and total protein were estimated both in plasma and tissue homogenates. The absorbance in all assays was measured with Infinite M200 PRO Multimode Microplate Reader, Tecan. The assays were performed in duplicates, except for the CAT (triplicate samples). Reagents for all the assays were obtained from Sigma-Aldrich, Germany (unless noted otherwise).

The activity of GPx (EC 1.11.1.9) was assessed colorimetrically by measuring the decrease in absorbance at 340 nm wavelength as a result of NADPH (chemically reduced form of nicotinamide adenine dinucleotide phosphate) oxidation. One unit of GPx activity was defined as the amount of the enzyme needed to catalyze the oxidation of 1 mmol NADPH per minute [13]. The results were expressed in units per mg of total protein.

The activity of CAT (EC 1.11.1.6) was determined colorimetrically by measuring the rate of hydrogen peroxide (H2O2) degradation at 240 nm [14]. One unit of CAT activity was defined as the amount of the enzyme needed to catalyze the decomposition of 1 mmol H2O2 per minute. CAT determination was performed in triplicate samples and the results were expressed in nmol H2O2 per mg of total protein.

The activity of SOD (EC 1.15.1.1) was analyzed colorimetrically by measuring the inhibition of adrenaline oxidation at 480 nm. One unit of SOD activity was defined as the amount of the enzyme needed to inhibit adrenaline oxidation by 50% [15]. The results were expressed as mU per mg of total protein.

The concentration of GSH was estimated colorimetrically by reaction with DTNB [5,5′-dithiobis-(2-nitrobenzoic acid)] to obtain a product with absorption maximum at 412 nm [16]. The results were expressed as μg per mg of total protein.

The concentration of UA was measured colorimetrically at 490 nm by reaction with 2,4,6-tripyridyl-s-triazine using the commercial kit QuantiChromTM Uric Acid Assay Kit DIUA-250 (BioAssay Systems, Hayward, CA, USA). The results were expressed as μg per mg of total protein.

The concentration of total protein was determined colorimetrically using the commercial kit Thermo Scientific PIERCE BCA Protein Assay (Rockford, IL, USA) with bovine serum album as a standard.

2.6. Total Antioxidant/Oxidant Status

Total antioxidant/oxidant status (total antioxidant capacity (TAC), ferric reducing ability of plasma (FRAP), and total oxidant status (TOS)) and total protein content were analyzed both in the plasma and tissue homogenates. The absorbance in all assays was measured with Infinite M200 PRO Multimode Microplate Reader, Tecan. All assays were performed in duplicate samples, excluding the TAC and TOS determination (triplicate samples).

The concentration of TAC was estimated at 660 nm by ABTS + [2,2′-azino-bis-(3-ethylbenzo-thiazoline-6-sulfonate)]-based colorimetric micromethod [17]. TAC determination was performed in triplicate samples, and the results were expressed as μmol Trolox equivalent per mg of total protein.

The concentration of TOS was estimated bichromatically (560/800 nm) based on the ferrous ion oxidation to ferric ion in the presence of oxidants in the sample [18]. TOS determination was performed in triplicate samples, and the results were expressed in μmol H2O2 equivalent per mg of total protein.

Oxidative stress index (OSI) was expressed in % according to the formula: OSI = TOS/TAC × 100% [19].

The concentration of FRAP was analyzed colorimetrically at 593 nm, measuring the ferric reducing ability of the sample by reaction with 2,4,6-tripyridyl-s-triazine [20]. The results were expressed in μmol per mg of total protein.

2.7. Oxidative Damage Determination

Oxidative damage products (advanced glycation end products (AGEs), advanced oxidation protein products (AOPP), 4-hydroxynonenal (4-HNE) protein adducts, and 8-hydroxydeoxyguanosine (8-OHdG)) and total protein content were analyzed both in plasma and tissue homogenates. The absorbance/fluorescence in all assays was measured with Infinite M200 PRO Multimode Microplate Reader, Tecan. All the assays were performed in duplicate samples.

The levels of AOPP were assessed colorimetrically at 340 nm by measuring the total iodide ion oxidizing capacity of the sample [21]. The results were expressed in μmol per mg of total protein.

The content of AGE was determined fluorimetrically at 350/440 nm in 1 : 5 diluted plasma samples and tissue homogenates [21]. The results were expressed in fluorescence per mg of total protein.

The concentration of 4-HNE protein adducts as well as 8-OHdG was measured with the commercial ELISA kit according to the manufacturer's instructions (OxiSelect™ HNE Adduct Competitive ELISA, Cell Biolabs Inc., San Diego, CA, USA; USCN Life Science, Wuhan, China, resp.). The results were expressed in μg/pg per mg of total protein.

2.8. Statistical Analysis

Statistical analysis was performed using the Statistica 10.0 system (StatSoft, Cracow, Poland) and GraphPad Prism (GraphPad Software, La Jolla, USA). The D'Agostino-Pearson test and Shapiro-Wilk test were used to examine normal distribution. Since most of the data were normally distributed, the results were presented as a mean, standard deviations, geometric mean, and 95th confidence intervals of mean. In the case of normal distribution of the results, a Student's t-test was used. In the lack of normal distribution of the results, the Mann–Whitney U test was used. The associations between the measured parameters were analyzed by Pearson's correlation. The results were assumed to be statistically significant when p < 0.05.

3. Results

3.1. Antioxidant Defence

CAT activity was significantly lower in mandibular periosteum and considerably higher in erythrocytes of the study group compared to the control group. SOD activity was significantly higher in patients with a mandibular fracture compared to the controls, while no statistically relevant changes were observed in erythrocytes. The concentration of UA was significantly higher both in mandibular periosteum and plasma of the study group patients than in the controls. The activity of GPx in mandibular periosteum and erythrocytes and GSH concentration in mandibular periosteum and plasma showed similar values in patients in the study and control groups (Tables 2 and 3).

Table 2.

Enzymatic and nonenzymatic antioxidants, antioxidant/oxidant status, and oxidative damage in the mandible (Man) of patients with titanium mandibular fixations and healthy controls.

Man Control group Study group
Mean SD Geometric mean Lower 95% CI of mean Upper 95% CI of mean Mean SD Geometric mean Lower 95% CI of mean Upper 95% CI of mean
CAT nmol H2O2/min/mg protein 1.435 0.349 0.973 1.312 2.747 0.605 0.139 0.272 0.556 1.160
SOD mU/mg protein 136.500 20.240 119.400 129.375 265.875 282.000 44.750 175.200 266.247 548.247
GPx IU/mg protein 0.024 0.003 0.022 0.022 0.046 0.027 0.006 0.025 0.025 0.052
UA μg/mg protein 0.155 0.024 0.125 0.146 0.301 0.285 0.040 0.234 0.271 0.556
GSH μg/mg protein 1.496 0.299 1.178 1.391 2.887 1.121 0.242 0.810 1.036 2.157
TAC μmol/mg protein 67.420 9.123 57.140 64.209 131.629 252.700 35.150 204.000 240.327 493.027
TOS μmol H2O2 Equiv./mg protein 1.088 0.186 0.895 1.023 2.111 1.953 0.632 1.202 1.730 3.683
OSI % 1.956 0.406 1.441 1.813 3.769 1.188 0.337 1.340 1.069 2.257
FRAP μg/mg protein 20.100 3.496 11.540 18.869 38.969 28.660 4.034 22.820 27.240 55.900
AGE fluorescence/mg protein 91.410 13.390 77.730 86.697 178.107 197.500 22.010 174.400 189.752 387.252
AOPP μmol/mg protein 1.911 0.242 1.743 1.826 3.737 2.607 0.246 2.318 2.521 5.128
4-HNE μg/mg protein 234.900 43.450 210.700 219.605 454.505 405.000 42.540 377.300 390.025 795.025
8-OHdG pg/mg protein 52.340 8.200 46.890 49.454 101.794 71.160 11.740 64.010 67.027 138.187
Total protein mg/mL 3094.000 288.400 2964.000 2992.480 6086.480 1948.000 210.000 1145.000 1874.078 3822.078

4-HNE: 4-hydroxynonenal protein adducts; 8-OHdG: 8-hydroxydeoxyguanosine; AGE: advanced glycation end products; AOPP: advanced oxidation protein products; CAT: catalase; FRAP: ferric reducing ability of plasma; GPx: glutathione peroxidase; GSH: reduced glutathione; Man: mandible; OSI: oxidative stress index; SOD: superoxide dismutase-1; TAC: total antioxidant status; TOS: total oxidant status; UA: uric acid; statistical significance p < 0.05, study group versus control.

Table 3.

Enzymatic and nonenzymatic antioxidants, antioxidant/oxidant status, and oxidative damage in the erythrocytes/plasma of patients with titanium mandibular fixations and healthy controls.

Erythrocytes/plasma Control group Study group
Mean SD Geometric mean Lower 95% CI of mean Upper 95% CI of mean Mean SD Geometric mean Lower 95% CI of mean Upper 95% CI of mean
CAT nmol H2O2/min/mg protein 6.900 1.047 5.127 6.531 13.431 48.830 5.823 39.510 46.780 95.610
SOD mU/mg protein 153.600 7.930 149.600 150.809 304.409 154.800 11.270 145.500 150.833 305.633
GPx IU/mg protein 0.020 0.002 0.019 0.019 0.039 0.020 0.001 0.019 0.019 0.039
UA μg/mg protein 0.658 0.011 0.656 0.654 1.312 0.733 0.012 0.730 0.729 1.462
GSH μg/mg protein 0.687 0.178 0.517 0.625 1.312 0.463 0.044 0.410 0.447 0.910
TAC μmol/mg protein 49.570 7.384 44.020 46.971 96.541 37.680 6.483 26.780 35.398 73.078
TOS μmol H2O2 Equiv./mg protein 0.629 0.186 0.508 0.564 1.193 0.382 0.055 0.316 0.363 0.745
OSI % 1.318 0.282 1.128 1.219 2.537 1.902 0.551 1.181 1.708 3.610
FRAP μg/mg protein 13.580 3.186 11.750 12.458 26.038 10.990 3.239 6.285 9.850 20.840
AGE fluorescence/mg protein 526.000 30.420 507.700 515.292 1041.292 603.500 180.100 365.200 540.103 1143.603
AOPP umol/mg protein 0.497 0.049 0.452 0.479 0.976 0.506 0.054 0.439 0.487 0.994
4-HNE μg/mg protein 80.890 12.860 70.980 76.363 157.253 108.500 17.570 93.980 102.315 210.815
8-OHdG pg/mg protein 27.350 4.247 21.110 25.855 53.205 32.750 5.534 27.510 30.802 63.552
Total protein mg/mL 4444.000 109.400 4416.000 4405.490 8849.490 3445.000 213.300 2712.000 3369.916 6814.916

4-HNE: 4-hydroxynonenal protein adducts; 8-OHdG: 8-hydroxydeoxyguanosine; AGE: advanced glycation end products; AOPP: advanced oxidation protein products; CAT: catalase; FRAP: ferric reducing ability of plasma; GPx: glutathione peroxidase; GSH: reduced glutathione; OSI: oxidative stress index; SOD: superoxide dismutase-1; TAC: total antioxidant status; TOS: total oxidant status; UA: uric acid; statistical significance p < 0.05, study group versus control.

3.2. Total Antioxidant/Oxidant Status

There was a statistically significant increase in TAC level in the mandibular periosteum of patients in the study group compared to healthy controls. There was also a considerable increase in TOS in the posttraumatic mandibular periosteum of study group patients compared to the controls. The decreased OSI value in patients with mandibular fracture compared to the control group was also observed. The FRAP level in the mandibular periosteum of the study group patients was significantly higher than in the control group. No statistically relevant changes in plasma TAC, TOS, OSI, and FRAP between the groups were demonstrated (Tables 2 and 3).

3.3. Oxidative Damage Products

There was a statistically significant increase in AGE fluorescence in the mandibular periosteum of the study group compared to AGE fluorescence in the control group. AOPP concentration in the mandibular periosteum of the study group was considerably higher than in the control group. There was a statistically relevant increase in the level of 4-HNE in the mandibular periosteum of patients with mandibular fracture compared to healthy controls. The content of AGE, AOPP, 4-HNE, and 8-OHdG in plasma of the study and control group was similar. The concentration of 8-OHdG in the mandibular periosteum of the traumatic patients yielded similar values to those obtained in mandibular periosteum in the control group (Tables 2 and 3).

3.4. Correlations

The results of all statistically significant correlations are presented in Table 4. Importantly, we have demonstrated a positive correlation between TAC concentration in the mandibular periosteum and UA level in plasma of patients in the study group. In this group, TOS concentration in the mandibular periosteum was positively correlated with CAT activity in erythrocytes as well as 8-OHdG level in the mandibular periosteum with GPx activity in erythrocytes.

Table 4.

Correlations of redox biomarkers in control group and patients with titanium mandibular fixations.

r p
Control group
TOS Man OSI Man 0.551 0.033
TAC Man UA plasma 0.425 0.043
GPx erythrocytes FRAP plasma 0.737 0.037
TAC plasma GSH plasma 0.608 0.003
8-OHdG plasma AOPP plasma 0.559 0.047
Study group
UA Man FRAP Man 0.519 0.019
TAC Man AGE Man 0.450 0.031
4-HNE Man OSI Man 0.592 0.043
8-OHdG Man AGE Man 0.883 0.000
TOS Man OSI Man 0.567 0.034
AGE Man GPx erythrocytes 0.574 0.025
TOS Man CAT erythrocytes 0.515 0.043
8-OHdG Man GPx erythrocytes 0.781 0.002
TAC Man UA plasma 0.425 0.043
4-HNE Man GSH plasma 0.662 0.019
GSH Man GSH plasma 0.417 0.048
SOD erythrocytes AGE plasma 0.470 0.020
TAC plasma AOPP plasma 0.695 0.000
TOS plasma AOPP plasma 0.529 0.000
TOS plasma GSH plasma 0.645 0.002
8-OHdG plasma GSH plasma 0.589 0.044

4-HNE: 4-hydroxynonenal protein adducts; 8-OHdG: 8-hydroxydeoxyguanosine; AGE: advanced glycation end products; AOPP: advanced oxidation protein products; CAT: catalase; FRAP: ferric reducing ability of plasma; GPx: glutathione peroxidase; GSH: reduced glutathione; Man: mandible; OSI: oxidative stress index; SOD: superoxide dismutase-1; TAC: total antioxidant status; TOS: total oxidant status; UA: uric acid.

4. Discussion

Our findings point to an increased occurrence of redox homeostasis disorders and oxidative stress in patients with mandible fractures treated surgically with titanium miniplates and screws. Although exposure to Ti6Al4V titanium alloy does not alter the clinical picture, the periosteum that contacted the titanium fixations of the mandible showed significantly higher concentrations of oxidation protein products and more extensive lipid modification compared to the control group. We also observed significant changes in the activity/concentration of enzymatic and nonenzymatic antioxidants in the periosteum as well as in the plasma and erythrocytes of the study group.

Titanium is widely used in many fields of medicine and dentistry due to its good biotolerance (biocompatibility) and its osseointegration ability to foster the contact thickening of bones [22]. Titanium and its alloys are used in the production of joint implants and external stabilizers as well as other metal components such as plates, clamps, screws, clips, dental implants, artificial valves, and vascular stents [22]. Their unique advantage is that they do not require removal for at least 20 years. Titanium miniplates and screws are also basic biomaterials used in the surgical treatment of mandibular fractures. One of the most commonly used titanium fixations in maxillofacial surgery is the Ti6Al4V alloy containing, in addition to titanium, 6% aluminium (Al) and 4% vanadium (V) [23]. Ti6Al4V demonstrates high mechanical strength and corrosion resistance due to the presence of a tight protective passive layer of titanium dioxide (TiO2) on the surface of the alloy [9, 24]. It is believed that the passive layer effectively protects the surface of the implant from the effects of corrosive agents present in the environment of body fluids [25]. However, there are reports stating that in the period from the implantation to the exploitation of the biomaterial, the TiO2 layer may be damaged, resulting in the release of metal ions (such as titanium, aluminium, or vanadium) into the surrounding tissues and organs [9]. In physiological conditions, the body content of these trace elements is very low. Corrosion of the implant, however, raises their concentration and may thus interfere with the process of their natural degradation. The local interaction of metal ions or products of the corrosion of metallic materials with the body tissues is referred to as metallosis [26].

The mandible is the only moving bone of the facial part of the skull. In patients with titanium implants, mandibular movements triggered by strong muscles cause micromovements of the fixed bone fragments, which increases the friction between the miniplates and the screws. This phenomenon is responsible for the corrosion of titanium fixations and the release of titanium ions to the tissues/organs surrounding the implants [3]. In our investigation, the deposition of titanium particles in the study group was observed in the form of gray periosteal discolourations adjacent to the titanium miniplates and screws (data not shown). Importantly, none of the patients had any symptoms of chronic and acute inflammation or healing disorders at the site of the fracture. All patients had their metal implants removed exclusively for reasons not connected to a health risk. Indeed, the most common reason for the removal of miniplates and screws (14 patients) was the desire to get rid of nonfunctional implants in order to avoid future reactions to a foreign body and to eliminate the risk of artefacts causing problems in the interpretation of CT and MRI.

Titanium belongs to the group of biocompatible elements that usually do not cause negative bodily reactions. However, in some people, titanium triggers allergic symptoms (local eczema, rush, and pruritus) [27] and is responsible for the periapical reaction (in the implant-tissue interlayer), which may lead to the destabilization of implants [28]. However, the mechanisms of titanium toxicity in the body are still not well known. Titanium is believed to be responsible for an increased production of oxygen-free radicals and RNS [9, 29]. This element may thus contribute to the induction of oxidative stress as well as structural and functional damage of the cells by the oxidation reaction. Oxidative stress results from overproduction of ROS and/or inadequate activity of the body's antioxidant systems [8, 30]. The products of the oxidative modification of proteins, lipids, and nucleic acids that emerge due to oxidative stress are directly responsible for the damage to the tissues and organs of the body [8]. A significant role in the prevention of oxidative stress is attributed to enzymatic (CAT, SOD, and GPx) and nonenzymatic antioxidants (e.g., UA, reduced glutathione, and vitamin C). These compounds inhibit the formation of free oxygen radicals and/or participate in their conversion into nonreactive derivatives [31]. The antioxidant enzymes are characterized by a greater selectivity of action, while the remaining antioxidants scavenge free radicals in a nonselective manner and/or interrupt the oxidation reaction in the cell [32]. Additionally, nonenzymatic antioxidants may affect the activity of antioxidant enzymes so that the action of one group of antioxidants depends on the other and vice versa [33]. SOD is responsible for the dismutation of the superoxide anion to hydrogen peroxide, which is then broken down by CAT and GPx enzymes. An important role in the defence against free radical overproduction is also carried out by UA, the main blood antioxidant, which constitutes 70–80% of the total antioxidant capacity [34].

The increased activity/concentration of antioxidants (↑SOD, ↑UA, ↑TAC, and ↑FRAP) in the mandibular periosteum of patients with titanium mandibular fixations, compared to the controls, suggests an adaptive reaction of the body in response to excessive ROS production (↑TOS) due to exposure to Ti6Al4V titanium alloy and its wear products. As Wang et al. [25] demonstrated, titanium ions released from implants may stimulate phagocytes (mainly macrophages) and osteoclasts to produce increased amounts of ROS and RNS. By participating in phagocytosis, they can also increase the activity of NADPH oxidase (NOX) [35] which is the main source of free radicals in the cell. High concentrations of ROS can initiate inflammation at the implantation site (by increasing the production of proinflammatory cytokines), which additionally (by positive feedback) increases the production of free oxygen radicals [5, 9, 29]. In our study, the induction of antioxidant defence mechanisms was observed not only in the periosteum but also in the plasma (↑UA) and erythrocytes (↑CAT) of the patients in the study group. These changes point not only to redox imbalances in the implantation site (mandibular periosteum) but also to systemic disorders (blood). A positive correlation found between TAC levels in the mandibular periosteum and the UA concentration in the plasma in the patients from the study group may indicate a relationship between the local and the central antioxidant response. These observations, however, require further research, especially on a larger number of patients with titanium mandibular fixations. The assessment of white cell populations and cytokines produced by oxidative stress may also be helpful for clarifying the systemic etiology of redox imbalance in these patients.

Interestingly, we have observed a significantly lower CAT activity in the periosteum of the patients in the study group versus healthy controls. The decrease in CAT activity may be explained by the exhaustion of the ability to neutralize hydrogen peroxide in the conditions of an overproduction of this tissue. In patients with titanium fixations of the mandible, a higher production of H2O2 may occur as the direct effect of titanium on the periosteal cells [5, 6, 33] or due to an increase in SOD activity that produces a large amount of hydrogen peroxide as a by-product of the dismutation reaction. This is confirmed by the results of our study (↑SOD in the mandible of the patients in the study group) and may be partially explained by the lack of changes in GPx specific activity.

Despite the increased defence capacity of the antioxidant systems (↑SOD, ↑UA, ↑TAC, and ↑FRAP), we can observe an increased oxidative damage of proteins (↑AGE and ↑AOPP) and lipids (↑4-HNE) in the mandibular periosteum contacting Ti6Al4V titanium alloy. These changes suggest that the body is not able to protect itself effectively against oxidative stress and free radical damage of cells at the site of implantation of miniplates and screws. Importantly, the observed increase in oxidative stress biomarkers did not depend on the time span between osteosynthesis and the removal of the mandibular fixations.

Redox balance disorders as well as products of oxidative damage to the cell components can have a negative impact on the bone remodelling process in patients with mandibular fractures [9, 36]. The proper healing of a fracture depends on the recruitment and differentiation of osteoprogenitor cells towards osteoblasts and osteoclasts. Therefore, this process depends on the production of components of the extracellular matrix of the bone, particularly collagen proteins [37]. It is well known that bone tissue, periosteum, bone marrow, and surrounding soft tissues are involved in the healing of bone fractures; however, a particular role is attributed to the periosteum [38, 39]. Microscopically, the periosteum consists of two layers: the external fibrous layer and the inner layer adhering to the bone (cambium) [40, 41]. In the outer fibrous layer, two sublayers can be distinguished: a superficial layer containing mainly collagen fibers with fibroblasts, which is rich in blood vessels and nerve fibers, and a deeper layer containing a lot of elastic fibers and collagen, a small number of cells and blood vessels. The outer fibrous layer provides elasticity and flexibility [40, 41]. The cambial layer (cambium) is composed of 3-4 cell layers of mainly osteoblasts and preosteoblastic cells and has osteogenic properties. This layer is responsible for the appearance of lamellar bone during growth and creation of woven bone after a fracture [4042]. In our investigation, all the patients in the study group were treated surgically using an anatomical setting of bone fragments with miniplates and screws. In the case of surgical treatment of fractures, little or no periosteal response is observed [38, 39]. Therefore, it may be assumed that the observed periosteal changes are mainly caused by exposure to titanium implants after fractures.

Oxidative damage to proteins and lipids that occurs due to the overproduction of ROS is responsible for the structural and functional changes of these biomolecules, and this in turn disrupts normal cellular and tissue homeostasis [36, 43]. Titanium ions and cytokines released by macrophages under the influence of the products of titanium implants degradation cause the generation and activation of fibroblasts and osteoclasts, stimulating osteolysis processes [44, 45]. They may also induce genomic instability in human fibroblast cells, which is of particular importance in young people [26], and can inhibit type I collagen synthesis by osteoblasts [46]. In the case of fracture healing, this condition may lead to an inadequate formation of the organic matrix of the bone and thus impair its biomechanical properties. As shown by Sheikhi et al. [47], oxidized lipids lead to osteoblastogenesis and simultaneously stimulate osteoclast activity.

We did not detect oxidative damage to the cell components in the plasma and erythrocytes of the study group patients, which indicates that, excluding the implantation site, the body is capable of preventing free radical damage caused by oxidative stress. A positive correlation between TOS Man and CAT erythrocytes as well as 8-OHdG Man and GPx erythrocytes proves that there is a correlation between the increased oxidative damage in the mandibular periosteum and the central redox disorders in patients with titanium miniplates and screws.

In conclusion, we have demonstrated the occurrence of redox imbalance as well as oxidative damage in the periosteum surrounding the Ti6Al4V titanium alloy. Changes in antioxidant efficiency in the patients treated with titanium implants were also observed in the plasma/erythrocytes, which proves both local and systemic influence of titanium on the human body. The obtained results indicate the need to improve the miniplates and screws used for osteosynthesis by increasing the thickness of the passive TiO2 layer or using new, biodegradable, and biocompatible materials (for instance based on magnesium and its alloys). Supplementation with antioxidants would also be helpful in patients treated with titanium fixations; however, further research is needed in this area.

Our work, apart from the undoubted advantages (careful selection of the group of young people (aged 21–29) with similar types of jaw fractures), also had some limitations. We evaluated only the most commonly used biomarkers of oxidative stress; therefore, the assessment of other parameters may lead to different observations and conclusions. It should also be borne in mind that changes in antioxidant defence as well as increased generation of the products of oxidative damage of proteins and lipids may indicate not only the body's response to the introduction of titanium miniplates and screws but also an ongoing callus remodelling in the course of mandibular fracture healing and the related increased protein metabolism.

Acknowledgments

This work was supported by the Medical University of Bialystok, Poland (Grant nos. N/ST/ZB/17/001/1109, N/ST/ZB/17/002/1109, N/ST/ZB/17/003/1109, N/ST/ZB/17/004/1109, and N/ST/MN/16/002/1109).

Conflicts of Interest

Authors declare no conflict of interest.

References

  • 1.Kuriakose M. A., Fardy M., Sirikumara M., Patton D. W., Sugar A. W. A comparative review of 266 mandibular fractures with internal fixation using rigid (AO/ASIF) plates or mini-plates. The British Journal of Oral & Maxillofacial Surgery. 1996;34(4):315–321. doi: 10.1016/S0266-4356(96)90010-8. [DOI] [PubMed] [Google Scholar]
  • 2.O’Connell J., Murphy C., Ikeagwuani O., Adley C., Kearns G. The fate of titanium miniplates and screws used in maxillofacial surgery: a 10 year retrospective study. International Journal of Oral and Maxillofacial Surgery. 2009;38(7):731–735. doi: 10.1016/j.ijom.2009.02.016. [DOI] [PubMed] [Google Scholar]
  • 3.Borys J., Maciejczyk M., Krętowski A. J., et al. The redox balance in erythrocytes, plasma, and periosteum of patients with titanium fixation of the jaw. Frontiers in Physiology. 2017;8 doi: 10.3389/fphys.2017.00386. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Voggenreiter G., Leiting S., Brauer H., et al. Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones. Biomaterials. 2003;24(2):247–254. doi: 10.1016/S0142-9612(02)00312-5. [DOI] [PubMed] [Google Scholar]
  • 5.Peters K., Unger R. E., Gatti A. M., Sabbioni E., Tsaryk R., Kirkpatrick C. J. Metallic nanoparticles exhibit paradoxical effects on oxidative stress and pro-inflammatory response in endothelial cells in vitro. International Journal of Immunopathology and Pharmacology. 2007;20(4):685–695. doi: 10.1177/039463200702000404. [DOI] [PubMed] [Google Scholar]
  • 6.Olmedo D. G., Tasat D. R., Evelson P., Guglielmotti M. B., Cabrini R. L. Biological response of tissues with macrophagic activity to titanium dioxide. Journal of Biomedical Materials Research Part A. 2008;84A(4):1087–1093. doi: 10.1002/jbm.a.31514. [DOI] [PubMed] [Google Scholar]
  • 7.Lee M.-C., Yoshino F., Shoji H., et al. Characterization by electron spin resonance spectroscopy of reactive oxygen species generated by titanium dioxide and hydrogen peroxide. Journal of Dental Research. 2005;84(2):178–182. doi: 10.1177/154405910508400213. [DOI] [PubMed] [Google Scholar]
  • 8.Valko M., Leibfritz D., Moncol J., Cronin M. T. D., Mazur M., Telser J. Free radicals and antioxidants in normal physiological functions and human disease. The International Journal of Biochemistry & Cell Biology. 2007;39(1):44–84. doi: 10.1016/j.biocel.2006.07.001. [DOI] [PubMed] [Google Scholar]
  • 9.Tsaryk R., Kalbacova M., Hempel U., et al. Response of human endothelial cells to oxidative stress on Ti6Al4V alloy. Biomaterials. 2007;28(5):806–813. doi: 10.1016/j.biomaterials.2006.09.033. [DOI] [PubMed] [Google Scholar]
  • 10.Choromańska M., Klimiuk A., Kostecka-Sochoń P., et al. Antioxidant defence, oxidative stress and oxidative damage in saliva, plasma and erythrocytes of dementia patients. Can salivary AGE be a marker of dementia? International Journal of Molecular Sciences. 2017;18(10):p. 2205. doi: 10.3390/ijms18102205. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Kolodziej U., Maciejczyk M., Miasko A., et al. Oxidative modification in the salivary glands of high fat-diet induced insulin resistant rats. Frontiers in Physiology. 2017;8 doi: 10.3389/fphys.2017.00020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Kołodziej U., Maciejczyk M., Niklińska W., et al. Chronic high-protein diet induces oxidative stress and alters the salivary gland function in rats. Archives of Oral Biology. 2017;84:6–12. doi: 10.1016/J.ARCHORALBIO.2017.09.006. [DOI] [PubMed] [Google Scholar]
  • 13.Paglia D. E., Valentine W. N. Studies on the quantitative and qualitative characterization of erythrocyte glutathione peroxidase. The Journal of Laboratory and Clinical Medicine. 1967;70(1):158–169. [PubMed] [Google Scholar]
  • 14.Aebi H. [13] Catalase in vitro. Methods in Enzymology. 1984;105:121–126. doi: 10.1016/S0076-6879(84)05016-3. [DOI] [PubMed] [Google Scholar]
  • 15.Misra H. P., Fridovich I. The role of superoxide anion in the autoxidation of epinephrine and a simple assay for superoxide dismutase. The Journal of Biological Chemistry. 1972;247(10, article 4623845):3170–3175. [PubMed] [Google Scholar]
  • 16.Moron M. S., Depierre J. W., Mannervik B. Levels of glutathione, glutathione reductase and glutathione S-transferase activities in rat lung and liver. Biochimica et Biophysica Acta (BBA) - General Subjects. 1979;582(1):67–78. doi: 10.1016/0304-4165(79)90289-7. [DOI] [PubMed] [Google Scholar]
  • 17.Erel O. A novel automated direct measurement method for total antioxidant capacity using a new generation, more stable ABTS radical cation. Clinical Biochemistry. 2004;37(4):277–285. doi: 10.1016/j.clinbiochem.2003.11.015. [DOI] [PubMed] [Google Scholar]
  • 18.Erel O. A new automated colorimetric method for measuring total oxidant status. Clinical Biochemistry. 2005;38(12):1103–11111. doi: 10.1016/j.clinbiochem.2005.08.008. [DOI] [PubMed] [Google Scholar]
  • 19.Knaś M., Maciejczyk M., Sawicka K., et al. Impact of morbid obesity and bariatric surgery on antioxidant/oxidant balance of the unstimulated and stimulated human saliva. Journal of Oral Pathology & Medicine. 2016;45(6):455–464. doi: 10.1111/jop.12383. [DOI] [PubMed] [Google Scholar]
  • 20.Benzie I. F. F., Strain J. J. The ferric reducing ability of plasma (FRAP) as a measure of “antioxidant power”: the FRAP assay. Analytical Biochemistry. 1996;239(1):70–76. doi: 10.1006/abio.1996.0292. [DOI] [PubMed] [Google Scholar]
  • 21.Kalousová M., Skrha J., Zima T. Advanced glycation end-products and advanced oxidation protein products in patients with diabetes mellitus. Physiological Research. 2002;51(6):597–604. [PubMed] [Google Scholar]
  • 22.Branemark R., Branemark P.-I., Rydevik B., Myers R. R. Osseointegration in skeletal reconstruction and rehabilitation: a review. Journal of Rehabilitation Research and Development. 2001;38(2):175–181. [PubMed] [Google Scholar]
  • 23.Cai Z., Shafer T., Watanabe I., Nunn M. E., Okabe T. Electrochemical characterization of cast titanium alloys. Biomaterials. 2003;24(2):213–218. doi: 10.1016/S0142-9612(02)00293-4. [DOI] [PubMed] [Google Scholar]
  • 24.Tengvall P., Elwing H., Sjöqvist L., Lundström I., Bjursten L. M. Interaction between hydrogen peroxide and titanium: a possible role in the biocompatibility of titanium. Biomaterials. 1989;10(2):118–120. doi: 10.1016/0142-9612(89)90043-4. [DOI] [PubMed] [Google Scholar]
  • 25.Wang J., Zhou G., Chen C., et al. Acute toxicity and biodistribution of different sized titanium dioxide particles in mice after oral administration. Toxicology Letters. 2007;168(2):176–185. doi: 10.1016/j.toxlet.2006.12.001. [DOI] [PubMed] [Google Scholar]
  • 26.Coen N., Kadhim M. A., Wright E. G., Case C. P., Mothersill C. E. Particulate debris from a titanium metal prosthesis induces genomic instability in primary human fibroblast cells. British Journal of Cancer. 2003;88(4):548–552. doi: 10.1038/sj.bjc.6600758. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Goutam M., Giriyapura C., Mishra S. K., Gupta S. Titanium allergy: a literature review. Indian Journal of Dermatology. 2014;59(6):p. 630. doi: 10.4103/0019-5154.143526. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Tawse-Smith A., Ma S., Siddiqi A., Duncan W. J., Girvan L., Hussaini H. M. Titanium particles in peri-implant tissues: surface analysis and histologic response. Clinical Advances in Periodontics. 2012;2(4):232–238. doi: 10.1902/cap.2012.110081. [DOI] [Google Scholar]
  • 29.Kalbacova M., Roessler S., Hempel U., et al. The effect of electrochemically simulated titanium cathodic corrosion products on ROS production and metabolic activity of osteoblasts and monocytes/macrophages. Biomaterials. 2007;28(22):3263–3272. doi: 10.1016/j.biomaterials.2007.02.026. [DOI] [PubMed] [Google Scholar]
  • 30.Maciejczyk M., Mikoluc B., Pietrucha B., et al. Oxidative stress, mitochondrial abnormalities and antioxidant defense in ataxia-telangiectasia, bloom syndrome and Nijmegen breakage syndrome. Redox Biology. 2017;11:375–383. doi: 10.1016/j.redox.2016.12.030. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Pisoschi A. M., Pop A. The role of antioxidants in the chemistry of oxidative stress: a review. European Journal of Medicinal Chemistry. 2015;97:55–74. doi: 10.1016/j.ejmech.2015.04.040. [DOI] [PubMed] [Google Scholar]
  • 32.Konopka T., Gmyrek-Marciniak A., Kozłowski Z., Kaczmarek U., Wnukiewicz J. Antioxidative potential of saliva with peridontitis and squamous cell carcinoma of lower oral cavity. Dental and Medical Problems. 2006;43:354–362. [Google Scholar]
  • 33.Żukowski P., Maciejczyk M., Waszkiel D. Sources of free radicals and oxidative stress in the oral cavity. Archives of Oral Biology. 2018;92:8–17. doi: 10.1016/j.archoralbio.2018.04.018. [DOI] [PubMed] [Google Scholar]
  • 34.Knaś M., Maciejczyk M., Waszkiel D., Zalewska A. Oxidative stress and salivary antioxidants. Dental and Medical Problems. 2013;50:461–466. [Google Scholar]
  • 35.Federico A., Morgillo F., Tuccillo C., Ciardiello F., Loguercio C. Chronic inflammation and oxidative stress in human carcinogenesis. International Journal of Cancer. 2007;121(11):2381–2386. doi: 10.1002/ijc.23192. [DOI] [PubMed] [Google Scholar]
  • 36.Wauquier F., Leotoing L., Coxam V., Guicheux J., Wittrant Y. Oxidative stress in bone remodelling and disease. Trends in Molecular Medicine. 2009;15(10):468–477. doi: 10.1016/j.molmed.2009.08.004. [DOI] [PubMed] [Google Scholar]
  • 37.Borys J., Grabowska S. Z., Antonowicz B., Dryl D., Citko A., Rogowski F. Collagen type I and III metabolism in assessment of mandible fractures healing. Roczniki Akademii Medycznej w Bialymstoku. 2004;49:237–245. [PubMed] [Google Scholar]
  • 38.Dimitriou R., Tsiridis E., Giannoudis P. V. Current concepts of molecular aspects of bone healing. Injury. 2005;36(12):1392–1404. doi: 10.1016/j.injury.2005.07.019. [DOI] [PubMed] [Google Scholar]
  • 39.Einhorn T. A. The cell and molecular biology of fracture healing. Clinical Orthopaedics and Related Research. 1998;355S, article 9917622:S7–S21. doi: 10.1097/00003086-199810001-00003. [DOI] [PubMed] [Google Scholar]
  • 40.Dwek J. R. The periosteum: what is it, where is it, and what mimics it in its absence? Skeletal Radiology. 2010;39(4):319–323. doi: 10.1007/s00256-009-0849-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Augustin G., Antabak A., Davila S. The periosteum. Part 1: anatomy, histology and molecular biology. Injury. 2007;38(10):1115–1130. doi: 10.1016/j.injury.2007.05.017. [DOI] [PubMed] [Google Scholar]
  • 42.Kuzenko Y. V., Romaniuk A. M., Horobchenko D. Periodontitis and atherosclerosis – mechanisms of association through matrix metalloproteinase 1 expression. Dental and Medical Problems. 2014;51:187–192. [Google Scholar]
  • 43.Halliwell B., Clement M. V., Long L. H. Hydrogen peroxide in the human body. FEBS Letters. 2000;486(1):10–13. doi: 10.1016/S0014-5793(00)02197-9. [DOI] [PubMed] [Google Scholar]
  • 44.Yang S. Y., Wu B., Mayton L., et al. Protective effects of IL-1Ra or vIL-10 gene transfer on a murine model of wear debris-induced osteolysis. Gene Therapy. 2004;11(5):483–491. doi: 10.1038/Sj.Gt.3302192. [DOI] [PubMed] [Google Scholar]
  • 45.Koreny T., Tunyogi-Csapó M., Gál I., Vermes C., Jacobs J. J., Glant T. T. The role of fibroblasts and fibroblast-derived factors in periprosthetic osteolysis. Arthritis and Rheumatism. 2006;54(10):3221–3232. doi: 10.1002/art.22134. [DOI] [PubMed] [Google Scholar]
  • 46.Vermes C., Chandrasekaran R., Jacobs J. J., Galante J. O., Roebuck K. A., Glant T. T. The effects of particulate wear debris, cytokines, and growth factors on the functions of MG-63 osteoblasts. The Journal of Bone and Joint Surgery. 2001;83(2):201–211. doi: 10.2106/00004623-200102000-00007. [DOI] [PubMed] [Google Scholar]
  • 47.Sheikhi M., Bouhafs R. K. L., Hammarstrom K.-J., Jarstrand C. Lipid peroxidation caused by oxygen radicals from Fusobacterium-stimulated neutrophils as a possible model for the emergence of periodontitis. Oral Diseases. 2001;7(1):41–46. doi: 10.1034/j.1601-0825.2001.0070109.x. [DOI] [PubMed] [Google Scholar]

Articles from Oxidative Medicine and Cellular Longevity are provided here courtesy of Wiley

RESOURCES