Is water exchange superior to water immersion in detecting adenomas during colonoscopies? Results from a Bayesian network meta-analysis

Xin Shi 1,*, Dan Tian 2,*, Xiaofei Ye 3,*, Qiong Wu 1, Yanglin Pan 1, Zhiping Yang 1, Daiming Fan 1
PMCID: PMC6078142  PMID: 30093978

Abstract

Aim

Water-assisted colonoscopy (water exchange [WE] and water immersion [WI]) has been shown to improve the adenoma detection rate. However, few studies have compared these two methods head-to-head. Thus, we conducted a network meta-analysis to integrate both direct and indirect evidence comparing the effectiveness of these two procedures.

Method

We searched PubMed, Web of Science, and the Cochrane Central Register of Controlled Trials for original papers and abstracts published up to March 2018. Randomized controlled trials (RCTs) reporting data in accordance with the eligibility criteria were included in this study. We performed a Bayesian random effects network meta-analysis with mixed comparisons.

Results

Twenty-nine studies (n = 11464 patients) including 6 direct and 23 indirect comparisons were included in this network meta-analysis. There was a statistically significant difference in the efficacy of adenoma detection when WE was compared with WI (risk ratio [RR]: 1.2, 95% credible interval [CrI]: 1.1–1.3), air insufflation (AI; RR: 1.3, 95% CrI: 1.1–1.4), and carbon dioxide (CO2) insufflation (RR: 1.2, 95% CrI: 1.1–1.5). The different methods were ranked in order from the most to least effective in adenoma detection as follows: WE, WI, AI, and CO2. Moreover, although there were no significant differences in pain scores, willingness to repeat, caecal intubation rate, or total procedure time between WI and WE colonoscopy, WE required a longer caecal intubation time than WI.

Conclusion

This network meta-analysis supposes that WE may be superior to WI in detecting adenomas during colonoscopies without affecting other technical features or patient acceptance.

Keywords: colonoscopy, water exchange, water immersion, colorectal adenoma, network meta-analysis

INTRODUCTION

A colonoscopy is considered the gold standard for diagnosing colonic diseases and an important therapeutic modality [1]. It can reduce the risk of death from colorectal cancer by detecting tumours at an earlier, more treatable stage and removing precancerous adenomas [2, 3]. The adenoma detection rate (ADR), defined as the proportion of patients with at least one adenoma detected during a screening colonoscopy in average-risk patients >50 years, has been shown to be inversely associated with the development of interval colorectal cancer [4, 5]. In our previous study, the recurrence rates of adenomas among post-polypectomy patients were high [6]. Thus, it is essential to improve the ADR to benefit patients undergoing a colonoscopy [7, 8].

Traditionally, a diagnostic colonoscopy begins with air insufflation (AI) to distend the colonic lumen to permit visualization and passage. Gas insufflation with either air or carbon dioxide (CO2) can be painful and poorly tolerated by patients [9, 10]. Due to these undesirable outcomes, investigators adopted the use of water-aided methods in lieu of gas insufflation to improve comfort during the insertion procedure. Water-aided methods comprise two major categories, namely, water immersion (WI) and water exchange (WE). WI is characterized by suction removal of the infused water during the withdrawal phase of a colonoscopy, and WE is characterized by suction removal of the infused water predominantly during the insertion phase [11, 12].

Recent studies revealed that, compared with AI, WE significantly improved the ADR [13, 14]. However, previous systematic reviews and meta-analyses showed controversial results regarding the differences between the ADRs of water infusion (water immersion or water exchange methods) and standard air insufflation for colonoscopies [1520] (Supplementary Table 1). Hafner S [15] found that adenoma detection rate was slightly improved with water infusion (risk ratio 1.16, 95% CI 1.04–1.30, P = 0.007). But others showed no significant statistical differences. To our knowledge, there are few studies with head-to-head comparisons of the ADRs associated with WE and WI. Thus, we conducted a network meta-analysis to determine the comparative effectiveness of different water-assisted methods during colonoscopy.

METHODS

The methodology and reporting of this study complies with the PRISMA statement for reporting systematic reviews that incorporated network meta-analyses of health care interventions [21].

Eligibility criteria

For this network meta-analysis, we only considered randomized controlled trials (RCTs) irrespective of publication status or date of publication. We excluded studies of other design because of the risk of bias associated with such studies. We included RCTs with participants who underwent a colonoscopy with or without sedation. We included RCTs that compared WI or WE with AI or CO2, and we excluded other assisted colonoscopy methods such as cap-assisted WI, water-assisted plus indigo carmine, and water-assisted plus CO2. Studies reporting both included and excluded populations were considered only if subject data specifically meeting the inclusion criteria for this network meta-analysis could be extracted (e.g., data for subjects who received WE as a single method in a trial comparing WE alone vs. WE with additional CO2). Abstracts reporting unpublished studies were also considered if sufficient data were reported.

Information sources and search

A bibliographic search was performed using PubMed, Web of Science, and the Cochrane Central Register of Controlled Trials to identify original studies analysing the efficacy of water-assisted colonoscopy. The search strategy was as follows: colonoscopy, water and randomized or randomized trial or clinical trial. Moreover, reference lists from the retrieved articles, systematic reviews and meta-analyses were evaluated to identify additional relevant studies. To obtain the maximum number of papers, no publication date restrictions were imposed in any database. The last search was completed in March 2018. Only English language publications were included in this study.

Study selection

Two investigators (X.S. and D.T.) independently identified trials for inclusion by screening titles and abstracts yielded by the search. To potentially include additional studies, we searched for full-length articles of all references from the studies that the investigators had identified in the initial search. We selected trials for inclusion based on the review of these full-length articles. Queries concerning inclusion were resolved by discussion and consensus between the two investigators.

Data extraction

Two investigators (X.S. and D.T.) independently extracted the following data from each study and summarized the data in tables: first author’s name, publication year, country, number of centres, registration numbers, interventions, indications, sedation, sample size, percentage of males, age of each intervention, number of participants per group, number of participants per group with at least one detected adenoma, pain score, willingness to repeat colonoscopy, number of participants per group who completed caecal intubation, caecal intubation time, and total procedure time. Differences in opinion between the investigators were resolved through discussion. Pain scores were derived from 0 to 10 visual analogue or numeric rating scales with 0 = none and 10 = most severe pain; if an included study reported 0–5 or other visual analogue scales, then the scores were converted. For continuous data, if an included RCT with a sample size larger than 100 reported only the median and interquartile range (IQR), then the median was regarded as the mean, and the standard deviation was calculated as IQR/1.35 [22].

Risk of bias assessment

We assessed the risk of bias as described in the Cochrane Handbook for Systematic Reviews of Interventions [23]. Bias risk assessment was performed with reference to the following domains: random sequence generation (selection bias), allocation concealment (selection bias), blinding of participants and personnel (performance bias), blinding of outcome assessment (detection bias), incomplete outcome data (attrition bias), selective reporting (reporting bias) and other detectable biases. Each risk of bias component was rated as low risk, unclear risk, or high risk of bias. A study with sufficient data to fulfill the criteria for the quality item was marked “low risk of bias”. A study in which the reported data did not fulfill the criteria for the quality item was marked “high risk of bias”. “Unclear risk of bias” was marked for studies that did not report the necessary data to assess the quality item.

Outcome measures

The primary outcome measure was the ADR, which was defined as the proportion of patients in whom at least one adenoma was detected during a colonoscopy. Secondary outcome measures were the mean and maximum pain scores (defined as the mean and maximum pain scores of patients during the colonoscopy), willingness to repeat rate (defined as the proportion of patients who were willing to repeat the procedure after the colonoscopy), caecal intubation rate, caecal intubation time, and total procedure time.

Statistical analysis

Given the limited number of studies that directly compared WE and WI, we used a network meta-analytical approach to simultaneously combine direct comparisons of these interventions within studies and, if available, indirect comparisons between studies. Whenever possible, we used results from intention-to-treat analyses. Network meta-analysis was conducted by using a Bayesian Markov-chain Monte Carlo method, and data were fitted in R statistical software version 3.3.2 (R Foundation for Statistical Computing, Vienna, Austria). Analytical results were presented as risk ratios (RRs) and mean differences (MDs) with 95% credible intervals (CrIs). A network diagram was used for each outcome to present the comparisons between different water-assisted colonoscopy methods and common AI or CO2. In these diagrams, nodes represented different methods of colonoscopies, lines indicated direct comparisons and line thickness was proportional to the number of available studies. We ranked methods of colonoscopy based on analysis of ranking probabilities derived from Monte Carlo simulations [24]. The probabilities of different rankings of the same intervention were summed to 100%. Inconsistency between direct and indirect evidence was assessed by a “node-splitting” approach [25].

We did not perform any subgroup analysis or sensitivity analysis due to the lack of data. We conducted Egger’s regression asymmetry test to examine potential publication bias in terms of ADR by using STATA software version 12.0 (Stata Corporation, College Station, Texas, USA).

RESULTS

Study selection

Figure 1 shows the detailed steps of the study selection process. The literature search yielded 479 potentially relevant studies. Of these, 32 potentially eligible studies were retrieved from the electronic databases, and 2 additional relevant studies were identified through a manual search of the reference section of identified articles and former meta-analyses, yielding a total of 34 studies. After excluding 5 studies based on the predefined inclusion criteria, 29 studies were included in the network meta-analysis.

Figure 1. Study flowchart.

Figure 1

Study characteristics and network geometry

Study characteristics and outcome measures of the 29 included studies are summarized in Table 1 and Supplementary Table 2. Six trials [2631] including 2088 patients (18.2%) were analysed in per-protocol, others were analysed in intention-to-treat. The studies were published between 2009 [32] and 2017 [13, 14, 33]. Study population sizes ranged from 23 [34] to 3303 [13], and 11464 patients were included in total, which equated to 1998 patients in the WI group, 3778 patients in the WE group, 4431 patients in the AI group, and 696 patients in the CO2 group. The proportion of male patients ranged from 30.4% [34] to 100% [31], and the mean patient age varied from 51.1 [35] to 69 [34] years in the WI group, 36 [36] to 65.6 [27] years in the WE group, 40.2 [36] to 67 [34] years in the AI group, and 54.3 [26] to 63.1 [27] years in the CO2 group.

Table 1. Study characteristics.

Author Year Country Centres Registration No. Interventions Indications Sedation Sample size Male (%) Age (y, mean ± SD)
WI WE AI CO2
Cadoni S [14] 2017 Italy, Czech 3 NCT02041507 WI, WE, AI Scr On-demand 1224 54.9 61 ± 6.3 61.4 ± 6.2 60.9 ± 6.2 -
Jia H [13] 2017 China 6 NR WE, AI Scr, Sur, and Dx Sedated 3303 51 - 50.3 ± 13.7 50.3 ± 13.9 -
Cadoni S [33] 2017 Italy, Czech 2 NCT02409979 WE, CO2 Dx On-demand 240 61.7 - 59 ± 13.1 - 58 ± 13.7
Hsieh YH [37] 2017 China 2 NCT01894191 WI, WE, AI Scr, Sur, and Dx Sedated 651 51.6 55.9 ± 10.2 55.7 ± 10.6 54.8 ± 10.5 -
Arai M [27] 2016 Japan 2 UMIN000009706 WE, CO2 NR Unsedated 403 61.3 - 65.6 ± 12 - 63.1 ± 12.6
Xu X [26] 2016 China 1 NR WI, AI, CO2 Dx Unsedated 287 48.3 54.3 ± 12.4 - 55 ± 10.7 54.3 ± 11.7
Falt P [36] 2015 Czech 1 NCT01933867 WE, AI Dx On-demand 92 53.3 - 36 ± 13 40.2 ± 14.6 -
Cadoni S [48] 2015 Italy 2 NCT01781650, NCT01780818 WI, WE, AI Scr, and Dx On-demand 576 58.7 60 ± 10.8 59 ± 11.3 59 ± 11.3 -
Cadoni S [49] 2015 Italy, Czech 2 NCT01954862 WI, WE, AI, CO2 Scr, and Dx On-demand 624 58.7 59 ± 12.3 58 ± 15.5 58 ± 12.7 59 ± 12.2
Wang X [28] 2015 China 1 NCT01735266 WE, AI 94-95% Dx Unsedated 300 47.3 - 46.6 ± 11.8 48.6 ± 13.2 -
Miroslav V [50] 2014 Yugoslavia 1 NR WI, AI Scr, Sur, and Dx Unsedated 122 47.5 54.4 ± 14.8 - 58 ± 13 -
Hsieh YH [38] 2014 China 1 NCT01535326 WI, WE, AI Scr, Sur, and Dx Minimal 270 62.2 54.3 ± 11.4 56.9 ± 10.3 56.5 ± 13.7 -
Cadoni S [29] 2014 Italy 2 NCT01463319 WE, AI Scr, Sur, and Dx On-demand 672 60.3 - 58 ± 12.4 60 ± 12.3 -
Leung J [39] 2013 USA 1 NCT01383252 WE, AI NR Unsedated 100 97 - 61 ± 7 60 ± 6.7 -
Amato A [40] 2013 Italy 1 NCT01259583 WI, AI, CO2 Scr, Sur, and Dx Unsedated 341 64.5 60 ± 11.5 - 60 ± 13.4 61.5 ± 14
Luo H [51] 2013 China 1 NCT01485133 WE, AI Scr, Sur, and Dx Unsedated 110 30.9 - 55.8 ± 11 56.6 ± 12 -
Bayupurnama P [35] 2013 Indonesia 1 NCT01341847 WI, AI Dx Unsedated 110 65.5 51.1 ± 14.7 - 50.4 ± 15.9 -
Hsieh YH [52] 2013 China 1 NCT0090555 WI, WE, AI Scr, Sur, and Dx Minimal 200 62 53 ± 12 57 ± 11 57 ± 13 -
Portocarrero DJ [34] 2012 USA 2 NR WI, AI Scr Unsedated 23 30.4 69 ± 10 - 67 ± 15 -
Falt P [30] 2012 Czech 1 NCT01440543 WI, AI, CO2 Scr, Sur, and Dx Minimal 420 51.7 60.1 ± 13.9 - 58.7 ± 13.8 59.4 ± 14.5
Hsieh YH [44] 2011 China 1 NR WI, AI Dx Minimal 153 56.9 52.4 ± 13.5 - 56.3 ± 13.2 -
Ramirez FC [41] 2011 USA 1 NR WE, AI Scr Minimal 368 96.5 - 60 ± 0.5 59.3 ± 0.5 -
Pohl J [42] 2011 Germany 1 DRKS00000431 WI, AI Scr, Sur, and Dx On-demand 116 73.3 62.7 ± 9.7 - 61.7 ± 11.5 -
Leung J [43] 2011 USA 1 NCT00920751 WI, AI Scr, Sur On-demand 100 99 60.7 ± 8.1 - 58.3 ± 7 -
Leung FW [47] 2010 USA 1 NCT00747084 WI, AI Scr, Sur, and Dx Unsedated 82 NA 66 ± 8.6 - 66.8 ± 8.4 -
Leung CW [31] 2010 USA 1 NCT00671177 WI, AI Scr, Sur, and Dx Minimal 229 100 62.5 ± 8.9 - 62.5 ± 8.9 -
Radaelli F [46] 2010 Italy 1 NCT00905554 WI, AI Scr, Sur, and Dx On-demand 230 58.3 58.4 ± 11.5 - 58.8 ± 13.3 -
Ransibrahmanakul K [45] 2010 USA 1 NCT00841282 WI, AI Scr, Sur Minimal 62 98.4 61 ± 7.9 - 61 ± 7.8 -
Leung JW [32] 2009 USA 1 NCT00785889 WI, AI Scr, Sur Minimal 56 91.1 60 ± 6.6 - 59 ± 8.6 -

USA, United States of America; NR, not reported; WI, water immersion; WE, water exchange; AI, air insufflation; CO2, carbon dioxide; Scr, screening; Sur, surveillance; Dx, diagnosis.

In 18 studies evaluating the ADR [13, 14, 27, 2931, 34, 3747], these rate ranged from 25% [46] to 54.5% [34] in the WI group, 18.3% [13] to 67.5% [27] in the WE group, 13.3% [13] to 46% [41] in the AI group, and 26.5% [30] to 57.8% [27] in the CO2 group. Of 27 studies evaluating pain scores [13, 2640, 4252], 13 studies evaluated the mean pain score [27, 2932, 3436, 40, 44, 46, 50, 52], which ranged from 1.3 [32] to 4.1 [31, 35, 50] in the WI group, 1.3 [29]to 4.3 [27] in the WE group, 2.3 [29, 30] to 6.4 [35] in the AI group, and 2 [30] to 4.8 [27] in the CO2 group, whereas 14 studies evaluated the maximum pain score [13, 26, 28, 33, 3739, 42, 43, 45, 4749, 51], which ranged from 2.3 [43] to 4 [49] in the WI group, 1.1 [28] to 3.3 [33] in the WE group, 2.9 [28] to 5.7 [26] in the AI group, and 2.9 [26] to 4.7 [33] in the CO2 group. In 21 studies evaluating the willingness to repeat rate [13, 14, 26, 28, 32, 34, 35, 3840, 4252], this rate ranged from 72.4% [42] to 100% [34, 38, 52] in the WI group, 76% [39] to 100% [38, 52] in the WE group, 48% [39] to 98.9% [38] in the AI group, and 88.7% [40] to 93.8% [26] in the CO2 group. In 27 studies evaluating caecal intubation time [13, 14, 2633, 3549, 51, 52], this timing ranged from 5.6 minutes [44] to 34 minutes [47] in the WI group, 6.9 minutes [41] to 17.5 minutes [52] in the WE group, 4.6 minutes [44] to 37 minutes [47] in the AI group, and 5 minutes [40] to 9.8 minutes [33] in the CO2 group. In 22 studies evaluating total procedure time [14, 26, 3037, 3949, 51], the total timing ranged from 14 minutes [34] to 56 minutes [47] in the WI group, 15.7 minutes [36] to 29 minutes [39] in the WE group, 13.1 minutes [44] to 56 minutes [47] in the AI group, and 13 minutes [40] to 20.5 minutes [49] in the CO2 group.

Figure 2 shows the network of comparisons for each outcome of interest. In relation to ADR, 3 trials compared WI and WE, 7 trials compared WE and AI, 1 trial compared WE and CO2, 13 trials compared WI and AI, 2 trials compared WI and CO2, and 2 trials compared AI and CO2.

Figure 2. Network of comparisons included in the analyses.

Figure 2

Solid lines represent direct comparisons within the RCTs. Numbers denote trials that compared corresponding interventions. (A) ADR; (B) mean pain scores; (C) maximum pain scores; (D) willingness to repeat; (E) caecal intubation rate; (F) caecal intubation time; and (G) total procedure time.

Quality of trials

The quality of the studies included in the network meta-analysis, as assessed using a risk of bias assessment tool, is shown in Figure 3 and Supplementary Figure 1. In relation to random sequence generation, most of the trials were rated as having a “low risk of bias” (19 of 29 trials), and regarding allocation concealment, 50% of trials were rated as having a “low risk of bias” (15 of 29 trials) because they used sealed opaque envelopes. Trials rated as having an “unclear risk of bias” had issues related to blinding of participants and personnel and of outcome assessment (27 and 26, respectively). In terms of attrition bias, reporting bias, and other biases, all trials were rated as having a “low risk of bias” except one [29], which was rated as having a “high risk of bias” in relation to reporting bias.

Figure 3. Risk of bias graph.

Figure 3

Meta-analysis

Figure 4 shows the results of the relative effect between any pair of interventions and each outcome of interest. There was a statistically significant difference in the ADR when WE was compared with WI (RR: 1.2, 95% CrI: 1.1–1.3), AI (RR: 1.3, 95% CrI: 1.1–1.4), and CO2 insufflation (RR: 1.2, 95% CrI: 1.1–1.5). In terms of mean and maximum pain scores, willingness to repeat, caecal intubation rate, and total procedure time, there were no significant differences between WI and WE colonoscopy. However, WE required a longer caecal intubation time than WI (MD: 3.3, 95% CrI: 1.5–5.1). Ranking probabilities for all methods are presented in Figure 5. The efficacies of the different methods in adenoma detection were ranked in order from the most to least effective as follows: WE (100%), WI (82%), AI (67%), and CO2 (73%).

Figure 4. Forest plots of each outcome.

Figure 4

Figure 4

(A) ADR; (B) mean pain scores; (C) maximum pain scores; (D) willingness to repeat; (E) caecal intubation rate; (F) caecal intubation time; and (G) total procedure time.

Figure 5. Ranking of method efficacy.

Figure 5

Figure 5

Figure 5

Figure 5

(A) ADR; (B) mean pain scores; (C) maximum pain scores; (D) willingness to repeat; (E) caecal intubation rate; (F) caecal intubation time; and (G) total procedure time.

Node-splitting analysis comparing results between direct and indirect estimates did not produce significant evidence of inconsistency, except when the caecal intubation time of WE was compared with that of AI or CO2 (both P = 0.04, see Supplementary Table 3). We then compared WE with AI or CO2 using an inconsistency model (MD: 2.66, 95% CrI: 1.05–4.19 and MD: 1.73, 95% CrI: –2.38–4.96, respectively).

Egger’s test of ADR for publication bias showed that the risk of having missed or overlooked trials was insignificant: WI vs. WE, P = 0.264; WI vs. AI, P = 0.331; WE vs. AI, P = 0.726. With regard to the remaining comparisons, we were unable to evaluate publication bias due to the small number of included studies.

Subgroup or sensitivity analysis was not conducted because of the limited data available.

DISCUSSION

Colonoscopies are widely used for prevention and early detection of colorectal cancer. The detection and removal of adenomas, which are major precursor lesions for colorectal cancer, is considered a crucial aspect of cancer prevention [53]. An increase in the ADR has been shown to reduce risks of interval colorectal cancer and colorectal cancer mortality [54], and the ADR has been codified as a key quality indicator for colonoscopy procedures [55, 56]. It has been estimated that every 1% increase in the ADR predicts a 3% decrease in the risk of interval cancer and a 5% decrease in the risk of a fatal interval cancer [57]. Recently published quality guidelines by the European Society of Gastrointestinal Endoscopy recommend that endoscopists achieve an ADR of ≥25% [58], and the American Society of Gastrointestinal Endoscopy recommended an ADR ≥30% in male patients and ≥20% in female patients [55].

The use of water in colonoscopies was first introduced in 1984 as a method for difficult sigmoid circumstances due to diverticulosis [59]. WE was first introduced in 2007 as a modification of WI [60]. The initial purpose of WI was to allow colonoscopists to correctly identify the colonic lumen in order to pass the colonoscope through sigmoid colons that were deformed by diverticulosis and, as a secondary endpoint, to provide a more comfortable procedure for the patients [15]. Thus far, comparative studies have not been able to distinguish the differences in the ADRs between these two colonoscopy approaches. Our network meta-analysis showed that, compared with WI colonoscopy, WE colonoscopy statistically significantly improved the ADR (RR: 1.2, 95% CrI: 1.1–1.3) but did not significantly affect the patients’ pain scores, willingness to repeat rate, caecal intubation rate, or total procedure time. However, WE significantly prolonged the caecal intubation time (MD: 3.3, 95% CrI: 1.5–5.1).

To date, there have been two head-to-head comparisons of WE, WI and AI using the ADR as the primary outcome. Cadoni et al [14] conducted an RCT with 408 patients per group, and ADR in the WE group was numerically higher than in the WI group (49.3% vs. 43.4%, P = 0.28). However, this difference was not significant. Another study enrolled 651 participants (217 per group) and found that the ADRs in the WE and WI groups were 49.8% and 40.6%, respectively [37]. Although the ADR of the WE group was numerically higher, this difference was also not significant (P = 0.064). Therefore, distinguishing the difference between the ADRs of the WE and WI groups may require a larger sample size. In addition, according to a previous study, a sample of 2447 patients per group would be required to show a significant difference in the ADR between WE and WI [14]. Despite the indirect nature of network meta-analysis, we found that WE method of colonoscopy improved the ADR when compared with WI.

The mechanism of the potential superiority of WE over WI is not fully understood. There were some plausible mechanisms of how WE could significantly increase adenoma detection. As shown in Supplementary Table 2 and previous reports [13, 14, 37, 38, 41], WE significantly increased the quality of colon cleanliness to excellent levels both in the entire colon and the ascending colon, and this quality ultimately led to an increase in the ADR. The WE method involves continuous water infusion and suction of residual faeces and air to clear the view, which enables better visualization of adenomas. The turbulence created at the tip of the colonoscope effectively dislodges residual faeces and debris adhered to the mucosa to facilitate removal by aspiration [14]. Inadequate or fair bowel preparation has been proven to be associated with an increased miss rate of adenoma detection [61, 62]. Thus, bowel cleanliness might have contributed to the increased ADR associated with the WE method. The reduced use of suction during the withdrawal step of the WE procedure has been shown to result in few collapses of the lumen or contractions of the colon; moreover, colonoscopists can concentrate on inspecting the colon instead of being distracted by the need to suction residual faeces and water [63]. The longer insertion time required by WE may also play a role in detecting more adenomas during insertion [11]. In addition, Hsieh et al [38] found that WE (24.4%) achieved a higher ADR during insertion than WI (15.6%) and AI (14.4%).

Previous studies reported that age ≥50 years, male gender, body mass index ≥25 kg/m2, Boston Bowel Preparation Scale (BBPS) score >6, indications of screening and surveillance, WE colonoscopy, and inspection time >8 minutes were significant predictors of increased adenoma detection [13, 37]. We noticed that the included studies showed a wide variation in these variables. Indications such as screening, surveillance, or diagnosis varied among studies, and the recruited patients with a history of colorectal adenoma remained at high risk for colorectal adenoma recurrence [64]. There were three trials [14, 34, 41] only included patients underwent screening colonoscopy, and five articles [26, 33, 36, 44] only included patients underwent diagnosis colonoscopy. Others included patients with indications for screening, surveillance, or diagnosis. This may contribute to potential selection bias. There was a wide variation in gender distribution, which was important because the ADR of men was significantly higher than that of women. Most of patients (≥90%) included in six trials [3132, 39, 41, 43, 45] were male which could also contribute potential selection bias in our study. However, the data were sparse, and thus, we could not conduct further analysis to control for these confounding factors.

Recent studies revealed that the pain scores associated with WE were considerably lower than those associated with WI [37, 38, 48, 49, 52, 65]. Our study showed that although the differences of the pain scores between WI and WE were not significant, the pain score of WE method was numerically lower. As shown in Figure 5, WE was considered as the least painful method for the ranking probabilities of mean and maximum pain scores (57% and 94% respectively). We needed to be cautious in interpreting the outcome of these pain scores because the pain scores most likely differed between participants who underwent the procedure with or without sedation. As the primary endpoint of the current study was ADR, we included patients regardless of whether they had been sedated. Thus, including patients with full and deep sedation in our study may have lessened the impact of the pain-alleviating effect of WE compared to WI.

In our analysis, we noticed that the pain score from CO2 insufflation was second only to that of AI. Previous studies reported that compared with AI or WE colonoscopy, CO2 insufflation could significantly reduce post-colonoscopy discomfort and pain but not reduce insertion pain during the colonoscopy [49, 6670]. CO2 is absorbed from the bowel more rapidly than air, which results in a reduction in post-colonoscopy gas volume, and is transported by the blood to the lungs, where it is exhaled [71]. Thus, the purpose of using CO2 in the procedure is to prevent or minimize post-colonoscopy colonic distension. A recent study suggested that the combination of WE during insertion and CO2 during withdrawal appears to be the optimal choice for decreasing pain during the examination and bloating and other outcomes after the procedure [33].

Our study included the following potential limitations: (1) a limited number of studies directly comparing WE and WI hindered us from conducting subgroup and sensitivity analysis; (2) the inherent indirectness of comparisons in a network meta-analytical approach; (3) in most of the studies, the endoscopists were not blinded to the patient outcomes. Nevertheless, our study is provocative enough to prompt an appropriate response of prospective randomized studies, and consideration given to evaluate the WE method by colonoscopists with low ADR is recommended [72]. Until additional data are available, we believe that WE may be considered superior to WI during colonoscopy.

SUPPLEMENTARY MATERIALS FIGURE AND TABLES

Abbreviations

WI

water immersion

WE

water exchange

AI

air insufflation

CO2

carbon dioxide

ADR

adenoma detection rate

RCT

randomized controlled trial

RR

risk ratio

MD

mean difference

CrI

credible interval

Footnotes

Author contributions

Conception and design: Yanglin Pan and Zhiping Yang; analysis and interpretation of the data: Xin Shi, Dan Tian, and Xiaofei Ye; drafting of the article: Xin Shi, Qiong Wu, and Zhiping Yang; critical revision of the article for important intellectual content: Yanglin Pan; and final approval of the article: Daiming Fan.

CONFLICTS OF INTEREST

All authors declare no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

FUNDING

This study was not supported by any pharmaceutical corporation or company; the publication fee was paid by the authors’ institution.

REFERENCES

  • 1.Rex DK, Johnson DA, Anderson JC, Schoenfeld PS, Burke CA, Inadomi JM, American College of Gastroenterology American College of Gastroenterology guidelines for colorectal cancer screening 2009 [corrected] Am J Gastroenterol. 2009;104:739–50. doi: 10.1038/ajg.2009.104. Erratum in: Am J Gastroenterol. 2009; 104:1613. [DOI] [PubMed] [Google Scholar]
  • 2.Nishihara R, Wu K, Lochhead P, Morikawa T, Liao X, Qian ZR, Inamura K, Kim SA, Kuchiba A, Yamauchi M, Imamura Y, Willett WC, Rosner BA, et al. Long-term colorectal-cancer incidence and mortality after lower endoscopy. N Engl J Med. 2013;369:1095–105. doi: 10.1056/NEJMoa1301969. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Zauber AG, Winawer SJ, O’Brien MJ, Lansdorp-Vogelaar I, van Ballegooijen M, Hankey BF, Shi W, Bond JH, Schapiro M, Panish JF, Stewart ET, Waye JD. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med. 2012;366:687–96. doi: 10.1056/NEJMoa1100370. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Lieberman D. Colorectal Cancer Screening With Colonoscopy. JAMA Intern Med. 2016;176:903–04. doi: 10.1001/jamainternmed.2016.1333. [DOI] [PubMed] [Google Scholar]
  • 5.Kaminski MF, Regula J, Kraszewska E, Polkowski M, Wojciechowska U, Didkowska J, Zwierko M, Rupinski M, Nowacki MP, Butruk E. Quality indicators for colonoscopy and the risk of interval cancer. N Engl J Med. 2010;362:1795–803. doi: 10.1056/NEJMoa0907667. [DOI] [PubMed] [Google Scholar]
  • 6.Shi X, Yang Z, Wu Q, Fan D. Colorectal adenoma recurrence rates among post-polypectomy patients in the placebo-controlled groups of randomized clinical trials: a meta-analysis. Oncotarget. 2017;8:62371–81. doi: 10.18632/oncotarget.18181. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Brand EC, Wallace MB. Strategies to Increase Adenoma Detection Rates. Curr Treat Options Gastroenterol. 2017;15:184–212. doi: 10.1007/s11938-017-0126-2. [DOI] [PubMed] [Google Scholar]
  • 8.Sung JJ, Ng SC, Chan FK, Chiu HM, Kim HS, Matsuda T, Ng SS, Lau JY, Zheng S, Adler S, Reddy N, Yeoh KG, Tsoi KK, et al. Asia Pacific Working Group An updated Asia Pacific Consensus Recommendations on colorectal cancer screening. Gut. 2015;64:121–32. doi: 10.1136/gutjnl-2013-306503. [DOI] [PubMed] [Google Scholar]
  • 9.Yamano HO, Yoshikawa K, Kimura T, Yamamoto E, Harada E, Kudou T, Katou R, Hayashi Y, Satou K. Carbon dioxide insufflation for colonoscopy: evaluation of gas volume, abdominal pain, examination time and transcutaneous partial CO2 pressure. J Gastroenterol. 2010;45:1235–40. doi: 10.1007/s00535-010-0286-5. [DOI] [PubMed] [Google Scholar]
  • 10.Bretthauer M, Hoff GS, Thiis-Evensen E, Huppertz-Hauss G, Skovlund E. Air and carbon dioxide volumes insufflated during colonoscopy. Gastrointest Endosc. 2003;58:203–06. doi: 10.1067/mge.2003.340. [DOI] [PubMed] [Google Scholar]
  • 11.Cadoni S, Leung FW. Water-Assisted Colonoscopy. Curr Treat Options Gastroenterol. 2017;15:135–54. doi: 10.1007/s11938-017-0119-1. [DOI] [PubMed] [Google Scholar]
  • 12.Leung FW. Water-aided colonoscopy. Gastroenterol Clin North Am. 2013;42:507–19. doi: 10.1016/j.gtc.2013.05.006. [DOI] [PubMed] [Google Scholar]
  • 13.Jia H, Pan Y, Guo X, Zhao L, Wang X, Zhang L, Dong T, Luo H, Ge Z, Liu J, Hao J, Yao P, Zhang Y, et al. Water Exchange Method Significantly Improves Adenoma Detection Rate: A Multicenter, Randomized Controlled Trial. Am J Gastroenterol. 2017;112:568–76. doi: 10.1038/ajg.2016.501. [DOI] [PubMed] [Google Scholar]
  • 14.Cadoni S, Falt P, Rondonotti E, Radaelli F, Fojtik P, Gallittu P, Liggi M, Amato A, Paggi S, Smajstrla V, Urban O, Erriu M, Koo M, Leung FW. Water exchange for screening colonoscopy increases adenoma detection rate: a multicenter, double-blinded, randomized controlled trial. Endoscopy. 2017;49:456–67. doi: 10.1055/s-0043-101229. [DOI] [PubMed] [Google Scholar]
  • 15.Hafner S, Zolk K, Radaelli F, Otte J, Rabenstein T, Zolk O. Water infusion versus air insufflation for colonoscopy. Cochrane Database Syst Rev. 2015 doi: 10.1002/14651858.CD009863.pub2. CD009863:CD009863. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Lin S, Zhu W, Xiao K, Su P, Liu Y, Chen P, Bai Y. Water intubation method can reduce patients’ pain and sedation rate in colonoscopy: a meta-analysis. Dig Endosc. 2013;25:231–40. doi: 10.1111/den.12018. [DOI] [PubMed] [Google Scholar]
  • 17.Jun WU, Bing HU. Comparative effectiveness of water infusion vs air insufflation in colonoscopy: a meta-analysis. Colorectal Dis. 2013;15:404–09. doi: 10.1111/j.1463-1318.2012.03194.x. [DOI] [PubMed] [Google Scholar]
  • 18.Rabenstein T, Radaelli F, Zolk O. Warm water infusion colonoscopy: a review and meta-analysis. Endoscopy. 2012;44:940–51. doi: 10.1055/s-0032-1310157. [DOI] [PubMed] [Google Scholar]
  • 19.Leung FW, Amato A, Ell C, Friedland S, Harker JO, Hsieh YH, Leung JW, Mann SK, Paggi S, Pohl J, Radaelli F, Ramirez FC, Siao-Salera R, Terruzzi V. Water-aided colonoscopy: a systematic review. Gastrointest Endosc. 2012;76:657–66. doi: 10.1016/j.gie.2012.04.467. [DOI] [PubMed] [Google Scholar]
  • 20.Leung F, Harker J, Leung J, Siao-Salera R, Mann S, Ramirez F, Friedland S, Amato A, Radaelli F, Paggi S, Terruzzi V, Hsieh Y. Removal of infused water predominantly during insertion (water exchange) is consistently associated with an increase in adenoma detection rate - review of data in randomized controlled trials (RCTs) of water-related methods. J Interv Gastroenterol. 2011;1:121–26. doi: 10.4161/jig.1.3.18517. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Hutton B, Salanti G, Caldwell DM, Chaimani A, Schmid CH, Cameron C, Ioannidis JP, Straus S, Thorlund K, Jansen JP, Mulrow C, Catalá-López F, Gøtzsche PC, et al. The PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of health care interventions: checklist and explanations. Ann Intern Med. 2015;162:777–84. doi: 10.7326/M14-2385. [DOI] [PubMed] [Google Scholar]
  • 22.Higgins JP. Cochrane Handbook for Systematic Reviews of Interventions. Version 5.1.0 [updated March 2011] Cambridge, UK: The Cochrane Collaboration; 2011. [Google Scholar]
  • 23.Higgins JP, Altman DG, Gøtzsche PC, Jüni P, Moher D, Oxman AD, Savovic J, Schulz KF, Weeks L, Sterne JA, Cochrane Bias Methods Group. Cochrane Statistical Methods Group The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. BMJ. 2011;343:d5928. doi: 10.1136/bmj.d5928. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Salanti G, Ades AE, Ioannidis JP. Graphical methods and numerical summaries for presenting results from multiple-treatment meta-analysis: an overview and tutorial. J Clin Epidemiol. 2011;64:163–71. doi: 10.1016/j.jclinepi.2010.03.016. [DOI] [PubMed] [Google Scholar]
  • 25.Dias S, Welton NJ, Caldwell DM, Ades AE. Checking consistency in mixed treatment comparison meta-analysis. Stat Med. 2010;29:932–44. doi: 10.1002/sim.3767. [DOI] [PubMed] [Google Scholar]
  • 26.Xu X, Zhu H, Chen D, Fan L, Lu T, Shen Q, Chen C, Deng D. Carbon dioxide insufflation or warm-water infusion for unsedated colonoscopy: A randomized controlled trial in patients with chronic constipation in China. Saudi J Gastroenterol. 2016;22:18–24. doi: 10.4103/1319-3767.173754. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Arai M, Okimoto K, Ishigami H, Taida T, Oyamada A, Minemura S, Saito K, Tsuboi M, Maruoka D, Matsumura T, Nakagawa T, Katsuno T, Mitsuhashi K, et al. A randomized controlled trial comparing water exchange and air insufflation during colonoscopy without sedation. Int J Colorectal Dis. 2016;31:1217–23. doi: 10.1007/s00384-016-2580-z. [DOI] [PubMed] [Google Scholar]
  • 28.Wang X, Luo H, Xiang Y, Leung FW, Wang L, Zhang L, Liu Z, Wu K, Fan D, Pan Y, Guo X. Left-colon water exchange preserves the benefits of whole colon water exchange at reduced cecal intubation time conferring significant advantage in diagnostic colonoscopy - a prospective, randomized controlled trial. Scand J Gastroenterol. 2015;50:916–23. doi: 10.3109/00365521.2015.1010569. [DOI] [PubMed] [Google Scholar]
  • 29.Cadoni S, Gallittu P, Sanna S, Fanari V, Porcedda ML, Erriu M, Leung FW. A two-center randomized controlled trial of water-aided colonoscopy versus air insufflation colonoscopy. Endoscopy. 2014;46:212–18. doi: 10.1055/s-0033-1353604. [DOI] [PubMed] [Google Scholar]
  • 30.Falt P, Liberda M, Smajstrla V, Kliment M, Bártková A, Tvrdík J, Fojtík P, Urban O. Combination of water immersion and carbon dioxide insufflation for minimal sedation colonoscopy: a prospective, randomized, single-center trial. Eur J Gastroenterol Hepatol. 2012;24:971–77. doi: 10.1097/MEG.0b013e3283543f16. [DOI] [PubMed] [Google Scholar]
  • 31.Leung CW, Kaltenbach T, Soetikno R, Wu KK, Leung FW, Friedland S. Water immersion versus standard colonoscopy insertion technique: randomized trial shows promise for minimal sedation. Endoscopy. 2010;42:557–63. doi: 10.1055/s-0029-1244231. [DOI] [PubMed] [Google Scholar]
  • 32.Leung JW, Mann SK, Siao-Salera R, Ransibrahmanakul K, Lim B, Cabrera H, Canete W, Barredo P, Gutierrez R, Leung FW. A randomized, controlled comparison of warm water infusion in lieu of air insufflation versus air insufflation for aiding colonoscopy insertion in sedated patients undergoing colorectal cancer screening and surveillance. Gastrointest Endosc. 2009;70:505–10. doi: 10.1016/j.gie.2008.12.253. [DOI] [PubMed] [Google Scholar]
  • 33.Cadoni S, Falt P, Gallittu P, Liggi M, Smajstrla V, Leung FW. Impact of carbon dioxide insufflation and water exchange on postcolonoscopy outcomes in patients receiving on-demand sedation: a randomized controlled trial. Gastrointest Endosc. 2017;85:210–218. .e1. doi: 10.1016/j.gie.2016.05.021. [DOI] [PubMed] [Google Scholar]
  • 34.Portocarrero DJ, Che K, Olafsson S, Walter MH, Jackson CS, Leung FW, Malamud A. A pilot study to assess feasibility of the water method to aid colonoscope insertion in community settings in the United States. J Interv Gastroenterol. 2012;2:20–22. doi: 10.4161/jig.20130. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Bayupurnama P, Neneng R, Fahmi I, Catharina T, Siti N. W LF. The water method colonoscopy in routine unsedated colonoscopy examinations: a randomized controlled trial in diagnostic cases in Indonesian patients. J Interv Gastroenterol. 2013;3:12. [Google Scholar]
  • 36.Falt P, Šmajstrla V, Fojtík P, Urban O, Hill M. Water-Aided Colonoscopy in Inflammatory Bowel Disease Patients-A Randomised, Single-Centre Trial. J Crohns Colitis. 2015;9:720–24. doi: 10.1093/ecco-jcc/jjv093. [DOI] [PubMed] [Google Scholar]
  • 37.Hsieh YH, Tseng CW, Hu CT, Koo M, Leung FW. Prospective multicenter randomized controlled trial comparing adenoma detection rate in colonoscopy using water exchange, water immersion, and air insufflation. Gastrointest Endosc. 2017;86:192–201. doi: 10.1016/j.gie.2016.12.005. [DOI] [PubMed] [Google Scholar]
  • 38.Hsieh YH, Koo M, Leung FW. A patient-blinded randomized, controlled trial comparing air insufflation, water immersion, and water exchange during minimally sedated colonoscopy. Am J Gastroenterol. 2014;109:1390–400. doi: 10.1038/ajg.2014.126. [DOI] [PubMed] [Google Scholar]
  • 39.Leung JW, Mann S, Siao-Salera R, Canete W, Prather D, Leung FW. The established and time-tested water exchange method in scheduled unsedated colonoscopy significantly enhanced patient-centered outcomes without prolonging procedural times– A randomized controlled trial. J Interv Gastroenterol. 2013;3:7. [Google Scholar]
  • 40.Amato A, Radaelli F, Paggi S, Baccarin A, Spinzi G, Terruzzi V. Carbon dioxide insufflation or warm-water infusion versus standard air insufflation for unsedated colonoscopy: a randomized controlled trial. Dis Colon Rectum. 2013;56:511–18. doi: 10.1097/DCR.0b013e318279addd. [DOI] [PubMed] [Google Scholar]
  • 41.Ramirez FC, Leung FW. A head-to-head comparison of the water vs. air method in patients undergoing screening colonoscopy. J Interv Gastroenterol. 2011;1:130–35. doi: 10.4161/jig.1.3.18512. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Pohl J, Messer I, Behrens A, Kaiser G, Mayer G, Ell C. Water infusion for cecal intubation increases patient tolerance, but does not improve intubation of unsedated colonoscopies. Clin Gastroenterol Hepatol. 2011;9:1039–43. e1. doi: 10.1016/j.cgh.2011.06.031. [DOI] [PubMed] [Google Scholar]
  • 43.Leung J, Mann S, Siao-Salera R, Ransibrahmanakul K, Lim B, Canete W, Samson L, Gutierrez R, Leung FW. A randomized, controlled trial to confirm the beneficial effects of the water method on U.S. veterans undergoing colonoscopy with the option of on-demand sedation. Gastrointest Endosc. 2011;73:103–10. doi: 10.1016/j.gie.2010.09.020. [DOI] [PubMed] [Google Scholar]
  • 44.Hsieh YH, Tseng KC, Hsieh JJ, Tseng CW, Hung TH, Leung FW. Feasibility of colonoscopy with water infusion in minimally sedated patients in an Asian Community Setting. J Interv Gastroenterol. 2011;1:185–90. doi: 10.4161/jig.1.4.19961. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Ransibrahmanakul K, Leung JW, Mann SK, Siao-Salera R, Lim BS, Hasyagar C, Yen D, Nastaskin I, Leung FW. Comparative Effectiveness of Water vs. Air Methods in Minimal Sedation Colonoscopy Performed by Supervised Trainees in the US - Randomized Controlled Trial. American Journal of Clinical Medicine. 2010;7:113–18. [Google Scholar]
  • 46.Radaelli F, Paggi S, Amato A, Terruzzi V. Warm water infusion versus air insufflation for unsedated colonoscopy: a randomized, controlled trial. Gastrointest Endosc. 2010;72:701–09. doi: 10.1016/j.gie.2010.06.025. [DOI] [PubMed] [Google Scholar]
  • 47.Leung FW, Harker JO, Jackson G, Okamoto KE, Behbahani OM, Jamgotchian NJ, Aharonian HS, Guth PH, Mann SK, Leung JW. A proof-of-principle, prospective, randomized, controlled trial demonstrating improved outcomes in scheduled unsedated colonoscopy by the water method. Gastrointest Endosc. 2010;72:693–700. doi: 10.1016/j.gie.2010.05.020. [DOI] [PubMed] [Google Scholar]
  • 48.Cadoni S, Sanna S, Gallittu P, Argiolas M, Fanari V, Porcedda ML, Erriu M, Leung FW. A randomized, controlled trial comparing real-time insertion pain during colonoscopy confirmed water exchange to be superior to water immersion in enhancing patient comfort. Gastrointest Endosc. 2015;81:557–66. doi: 10.1016/j.gie.2014.07.029. [DOI] [PubMed] [Google Scholar]
  • 49.Cadoni S, Falt P, Gallittu P, Liggi M, Mura D, Smajstrla V, Erriu M, Leung FW. Water Exchange Is the Least Painful Colonoscope Insertion Technique and Increases Completion of Unsedated Colonoscopy. Clin Gastroenterol Hepatol. 2015;13:1972–80. .e1-3. doi: 10.1016/j.cgh.2015.04.178. [DOI] [PubMed] [Google Scholar]
  • 50.Miroslav V, Klemen M. Warm water immersion vs. standard air insufflation for colonoscopy: comparison of two techniques. Hepatogastroenterology. 2014;61:2209–11. [PubMed] [Google Scholar]
  • 51.Luo H, Zhang L, Liu X, Leung FW, Liu Z, Wang X, Xue L, Wu K, Fan D, Pan Y, Guo X. Water exchange enhanced cecal intubation in potentially difficult colonoscopy. Unsedated patients with prior abdominal or pelvic surgery: a prospective, randomized, controlled trial. Gastrointest Endosc. 2013;77:767–73. doi: 10.1016/j.gie.2012.12.007. [DOI] [PubMed] [Google Scholar]
  • 52.Hsieh YH, Leung FW. A randomized, controlled trial comparing air insufflation, water immersion and water exchange during minimally sedated colonoscopy - an interim report. J Interv Gastroenterol. 2013;3:96–99. doi: 10.1038/ajg.2014.126. [DOI] [PubMed] [Google Scholar]
  • 53.Kahi CJ, Rex DK, Imperiale TF. Screening, surveillance, and primary prevention for colorectal cancer: a review of the recent literature. Gastroenterology. 2008;135:380–99. doi: 10.1053/j.gastro.2008.06.026. [DOI] [PubMed] [Google Scholar]
  • 54.Kaminski MF, Wieszczy P, Rupinski M, Wojciechowska U, Didkowska J, Kraszewska E, Kobiela J, Franczyk R, Rupinska M, Kocot B, Chaber-Ciopinska A, Pachlewski J, Polkowski M, Regula J. Increased Rate of Adenoma Detection Associates With Reduced Risk of Colorectal Cancer and Death. Gastroenterology. 2017;153:98–105. doi: 10.1053/j.gastro.2017.04.006. [DOI] [PubMed] [Google Scholar]
  • 55.Rex DK, Schoenfeld PS, Cohen J, Pike IM, Adler DG, Fennerty MB, Lieb JG, 2nd, Park WG, Rizk MK, Sawhney MS, Shaheen NJ, Wani S, Weinberg DS. Quality indicators for colonoscopy. Gastrointest Endosc. 2015;81:31–53. doi: 10.1016/j.gie.2014.07.058. [DOI] [PubMed] [Google Scholar]
  • 56.Steele RJ, Pox C, Kuipers EJ, Minoli G, Lambert R, International Agency for Research on Cancer European guidelines for quality assurance in colorectal cancer screening and diagnosis. First Edition--Management of lesions detected in colorectal cancer screening. Endoscopy. 2012;44(Suppl 3):SE140–50. doi: 10.1055/s-0032-1309802. [DOI] [PubMed] [Google Scholar]
  • 57.Corley DA, Jensen CD, Marks AR, Zhao WK, Lee JK, Doubeni CA, Zauber AG, de Boer J, Fireman BH, Schottinger JE, Quinn VP, Ghai NR, Levin TR, Quesenberry CP. Adenoma detection rate and risk of colorectal cancer and death. N Engl J Med. 2014;370:1298–306. doi: 10.1056/NEJMoa1309086. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Kaminski MF, Thomas-Gibson S, Bugajski M, Bretthauer M, Rees CJ, Dekker E, Hoff G, Jover R, Suchanek S, Ferlitsch M, Anderson J, Roesch T, Hultcranz R, et al. Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative. Endoscopy. 2017;49:378–97. doi: 10.1055/s-0043-103411. [DOI] [PubMed] [Google Scholar]
  • 59.Falchuk ZM, Griffin PH. A technique to facilitate colonoscopy in areas of severe diverticular disease. N Engl J Med. 1984;310:598. doi: 10.1056/NEJM198403013100919. [DOI] [PubMed] [Google Scholar]
  • 60.Leung JW, Mann S, Leung FW. Options for screening colonoscopy without sedation: a pilot study in United States veterans. Aliment Pharmacol Ther. 2007;26:627–31. doi: 10.1111/j.1365-2036.2007.03404.x. [DOI] [PubMed] [Google Scholar]
  • 61.Menees SB, Kim HM, Elliott EE, Mickevicius JL, Graustein BB, Schoenfeld PS. The impact of fair colonoscopy preparation on colonoscopy use and adenoma miss rates in patients undergoing outpatient colonoscopy. Gastrointest Endosc. 2013;78:510–16. doi: 10.1016/j.gie.2013.03.1334. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62.Chokshi RV, Hovis CE, Hollander T, Early DS, Wang JS. Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy. Gastrointest Endosc. 2012;75:1197–203. doi: 10.1016/j.gie.2012.01.005. [DOI] [PubMed] [Google Scholar]
  • 63.Yen AW, Yung VY, Leung JW, Mann SK, Wilson MD, Leung FW. Insertion water exchange minimizes endoscopist multitasking during withdrawal inspection - a plausible explanation for enhanced polyp detection in the right colon. J Interv Gastroenterol. 2015;5:3–9. [Google Scholar]
  • 64.Martínez ME, Baron JA, Lieberman DA, Schatzkin A, Lanza E, Winawer SJ, Zauber AG, Jiang R, Ahnen DJ, Bond JH, Church TR, Robertson DJ, Smith-Warner SA, et al. A pooled analysis of advanced colorectal neoplasia diagnoses after colonoscopic polypectomy. Gastroenterology. 2009;136:832–41. doi: 10.1053/j.gastro.2008.12.007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65.Leung F, Harker J, Leung J, Siao-Salera R, Mann S, Ramirez F, Friedland S, Amato A, Radaelli F, Paggi S, Terruzzi V, Hsieh Y. Removal of infused water predominantly during insertion (water exchange) is consistently associated with a greater reduction of pain score - review of randomized controlled trials (RCTs) of water method colonoscopy. J Interv Gastroenterol. 2011;1:114–20. doi: 10.4161/jig.1.3.18510. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 66.Memon MA, Memon B, Yunus RM, Khan S. Carbon Dioxide Versus Air Insufflation for Elective Colonoscopy: A Meta-Analysis and Systematic Review of Randomized Controlled Trials. Surg Laparosc Endosc Percutan Tech. 2016;26:102–16. doi: 10.1097/SLE.0000000000000243. [DOI] [PubMed] [Google Scholar]
  • 67.Lo SK, Fujii-Lau LL, Enestvedt BK, Hwang JH, Konda V, Manfredi MA, Maple JT, Murad FM, Pannala R, Woods KL, Banerjee S, ASGE Technology Committee The use of carbon dioxide in gastrointestinal endoscopy. Gastrointest Endosc. 2016;83:857–65. doi: 10.1016/j.gie.2016.01.046. [DOI] [PubMed] [Google Scholar]
  • 68.Homan M, Mahkovic D, Orel R, Mamula P. Randomized, double-blind trial of CO2 versus air insufflation in children undergoing colonoscopy. Gastrointest Endosc. 2016;83:993–97. doi: 10.1016/j.gie.2015.08.073. [DOI] [PubMed] [Google Scholar]
  • 69.Chen SW, Hui CK, Chang JJ, Lee TS, Chan SC, Chien CH, Hu CC, Lin CL, Chen LW, Liu CJ, Yen CL, Hsieh PJ, Liu CK, et al. Carbon dioxide insufflation during colonoscopy can significantly decrease post-interventional abdominal discomfort in deeply sedated patients: A prospective, randomized, double-blinded, controlled trial. J Gastroenterol Hepatol. 2016;31:808–13. doi: 10.1111/jgh.13181. [DOI] [PubMed] [Google Scholar]
  • 70.Garborg K, Kaminski MF, Lindenburger W, Wiig H, Hasund A, Wronska E, Bie RB, Kleist B, Løvdal L, Holme Ø, Kalager M, Hoff G, Bretthauer M. Water exchange versus carbon dioxide insufflation in unsedated colonoscopy: a multicenter randomized controlled trial. Endoscopy. 2015;47:192–99. doi: 10.1055/s-0034-1390795. [DOI] [PubMed] [Google Scholar]
  • 71.Bretthauer M, Lynge AB, Thiis-Evensen E, Hoff G, Fausa O, Aabakken L. Carbon dioxide insufflation in colonoscopy: safe and effective in sedated patients. Endoscopy. 2005;37:706–09. doi: 10.1055/s-2005-870154. [DOI] [PubMed] [Google Scholar]
  • 72.Leung F, Jia H, Pan Y. Air Insufflation May Still be Ideal for Adenoma Detection. Am J Gastroenterol. 2017;112:1615–16. doi: 10.1038/ajg.2017.255. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials


Articles from Oncotarget are provided here courtesy of Impact Journals, LLC

RESOURCES