Abstract
Background and Aims
Missed polyps are a pitfall of colonoscopy. In this study, we analyzed the efficacy of an additional 30 seconds observation using linked color imaging (LCI) for detecting adenoma and sessile serrated adenoma/polyp (SSA/P).
Materials and Methods
We enrolled patients undergoing colonoscopy from February to October 2017 in two institutions. In all patients, the cecum and ascending colon were observed with white light imaging (WLI) first. The colonoscope was inserted again, and the cecum and ascending colon were observed for an additional 30 seconds using either LCI or WLI. The method for the 30 sec observation was to insufflate the cecum and ascending colon sufficiently and observe them in a distant view, because the length of the second observation was determined to be precisely 30 sec. For the second observation, LCI was performed for the first 65 patients and WLI for the next 65. Adenoma and SSA/P detection rate (ASDR) in the second observation were examined in both groups. According to a pilot study, the sample size was estimated 65.
Results
In the first observation, ASDR were 30.7% in the LCI group and 32.2% in the WLI group (p = 0.85). For the second observation, 13 polyps were detected in the LCI group and 5 polyps in the WLI group (p = 0.04). Additionally, ASDR for the second observation were 18.5% and 6.1%, respectively (p = 0.03). There were no significant differences between the LCI and WLI groups with respect to morphology (ratio of polypoid) (38.5% versus 60.0%, p = 0.52) and histology (ratio of adenoma) (92.3% versus 100.0%, p = 0.91). Total adenoma and SSA/P number were 48 in the LCI group and 36 in the WLI group (p = 0.02).
Conclusion
The 30 seconds additional observation with LCI improved the detection of adenoma and SSA/P in the right-sided colon.
1. Introduction
Removal of adenomatous polyps by colonoscopy has been proven to prevent colorectal cancer and associated with the reduction in the incidence of proximal and distal colorectal cancers [1–3]. Colonoscopy is the most effective tool for detecting colorectal adenomas. However, the rate of missed polyps by white light imaging (WLI) observation was reported at 20–27% [4, 5]. There are some risk factors for missed polyps, such as flat morphology, smaller size, presence in the ascending colon, male sex, patients with multiple polyps at their first colonoscopy, and patients with a history of polyps [6, 7].
A LASER endoscopic system (LASEREO: Fujifilm Co., Tokyo, Japan) was developed in 2012. It allows blue laser imaging (BLI), BLI-bright, and linked color imaging (LCI) as narrow band light observation [8–11]. BLI is used with magnification and is useful for diagnosing various gastrointestinal cancers. BLI-bright is brighter than BLI and is expected to improve tumor detection. For colorectal tumors, BLI-bright makes a neoplastic lesion appear brownish in color and makes it easier to detect. Previously, we reported that BLI-bright improved numbers of polyps and adenomas more significantly than WLI did in a multicenter study [12]. However, there are several limitations in the use of BLI and BLI-bright. One of the limitations is that the residual liquid becomes reddish, which worsens the endoscopic view. Narrow band imaging (NBI) also has this limitation. The other limitation is that the endoscopic view using BLI and BLI-bright is darker than in WLI. However, LCI is brighter than BLI and BLI-bright and differentiates a lesion from the surrounding mucosa by making it appear reddish and the surrounding mucosa appears whitish, making the lesion easy to visualize. Moreover, residual liquid becomes yellowish with LCI. We previously reported that LCI improved polyp visibility using endoscopic figures and movies [13, 14]. However, there are no previous reports about whether LCI can decrease missed polyps.
In this study, we developed an additional 30 seconds (sec) observation as a second observation with LCI for decreasing missed adenoma and sessile serrated adenoma and polyp (SSA/P) and analyzed the efficacy of this method.
2. Materials and Methods
This was an observational study and was conducted at two affiliated hospitals: the Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, and the Department of Gastroenterology, North Medical Center, Kyoto Prefectural University of Medicine. We examined 130 consecutive patients who received total colonoscopy using LCI and WLI with the LASER endoscopic system (LL-4450 light source, the VP-4450HD, Fujifilm Co., Tokyo, Japan) and the LASER endoscope (EC-L600ZP) from February 2017 to October 2017. We divided all patients into a LCI or a WLI group. First, in all patients, the cecum and ascending colon were observed with WLI as the first observation (Figure 1). Next, we inserted the colonoscope in the cecum again, and the cecum and ascending colon were observed for an additional 30 sec using either LCI or WLI as the second observation. In the first 65 cases, LCI was performed, and in the next 65 cases, WLI was used. The method for the 30 sec observation was to insufflate the cecum and the ascending colon sufficiently and observe them not in a close view, but in a distant view, because the length of the second observation was determined to be precisely 30 sec. Thus, even if the observation of the cecum and ascending colon had not finished during the 30 sec, the second observation would have finished. In this study, the number of adenoma and SSA/P detected in the first observation and the second observation was examined. The diagnosis of adenoma and SSA/P was performed with BLI magnification according to previous reports and local protocols based on the Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) statements, and all polyps diagnosed as either adenoma or SSA/P were resected using polypectomy, endoscopic mucosal resection (EMR), and endoscopic submucosal dissection (ESD) according to size and morphology [9, 15, 16]. Polyps diagnosed as hyperplastic polyps and inflammatory polyps were diagnosed with biopsy.
As the main purpose of this study, the number of adenoma and SSA/P in the second observation was analyzed in the LCI group compared to that in the WLI group. The number of adenoma and SSA/P in the first observation was also analyzed both in the LCI and WLI groups, respectively. Moreover, adenoma detection rates (ADR) and adenoma and SSA/P detection rates (ASDR) both in the first and second observations were calculated. Polyp characteristics such as size, location, morphology, and histology were examined in each group. Additionally, patient characteristics such as mean age, sex, insertion time, first observation time, local Boston bowel preparation score (BBPS) for the cecum and ascending colon, usage of antispasm drugs, and sedation were examined. Overall, adenoma and SSS/P numbers, adenoma numbers, ASDR, and ADR in the first and second observations in each group were analyzed. Removal time for detected polyps was not included for either the 1st observation or the 2nd observation. Moreover, polyps detected during removal were not included in this study.
The inclusion criteria were as follows: patients receiving total colonoscopies for follow-up of polyps, surveillance after polyp or cancer resection, and positive fecal occult blood performed by three experts (N.Y., Y.I., and T.M.). We excluded patients with recurrent lesions after a previous EMR and polypectomy, and T1–T4 colorectal cancers. We also excluded patients who underwent surgical operations of the cecum or the ascending colon. Of the three endoscopists, all had performed more than 1000 colonoscopies and 50 withdrawing colonoscopies with LCI prior to this study. The size of a polyp was defined by its maximum diameter and was calculated in accordance with the size of the snares and biopsy forceps. Polyps were divided into polypoid and nonpolypoid types, according to the Paris classification [17]. Histological diagnosis was performed according to the World Health Organization classification, and intramucosal cancer was categorized as adenoma in this study [18].
Regarding bowel preparation, patients followed a low-residue diet and took 10 mL of sodium picosulfate with 200 mL of water one day before the examination. All patients also received a total of 1.0 L of a highly concentrated polyethylene glycol solution with ascorbic acid (MOVIPREP; Ajinomoto Pharma Co., Ltd., Tokyo, Japan) and more than 0.5 L of water in the morning on the day of the examination according to our previous report [19].
All patients provided written informed consent to participate in this study. This study was conducted in accordance with the World Medical Association Helsinki Declaration. This study was also approved by the institutional review board and the ethics committees of Kyoto Prefectural University of Medicine.
2.1. Statistical Assessment
Regarding the sample size, we hypothesized that LCI improves the number of adenoma and SSAP by 20% in the second observation according to our pilot study of 20 cases by a single expert endoscopist (N.Y.). Using the sign test, the α error was calculated at 5% and the β error at 20%. The calculated minimum sample size was 47. We considered the exclusion cases and finally determined the sample size to be 65. The Mann–Whitney U test, Wilcoxon signed-rank test with Bonferroni correction, and chi-squared test (SPSS version 22.0 for Windows, IBM Japan, Ltd., Tokyo, Japan) were used in this study. Continuous variables such as patient age and tumor size were analyzed using the Mann–Whitney U test. A p value of < 0.05 was considered statistically significant.
3. Results
The patients' characteristics in the LCI group and the WLI group are shown in Table 1. The first observation times (sec) for each group were 162 ± 80 in the LCI group and 169 ± 112 in the WLI group (p = 0.77). There was no significant difference in the ratio of local BBPS ≥ 2 for the cecum and the ascending colon (LCI versus WLI: 84.6 versus 87.6, p = 0.61). On the contrary, regarding poor preparation cases showing BBPS 0 or 1, there were 10 in the LCI group and 8 in the WLI group.
Table 1.
LCI | WLI | p value | |
---|---|---|---|
Case number | 65 | 65 | |
Age, years, mean ± SD | 63.5 ± 13.0 | 68.1 ± 14.3 | 0.10 |
Sex, %, n men : women |
60.0 : 40.0 34 : 31 |
62.3 : 37.7 38 : 27 |
0.48 |
Insertion time, sec | 284 ± 151 | 328 ± 202 | 0.33 |
First WLII observation time, sec | 162 ± 80 | 169 ± 112 | 0.77 |
BBPS ≥ 2, %, n | 84.6, 55 | 87.6, 57 | 0.61 |
Antispasm drug, %, n | 80.0, 57 | 71.5, 58 | 0.78 |
Sedation, %, n | 23.1, 15 | 12.3, 8 | 0.11 |
LCI: linked color imaging; WLI: white light; BBPS: Boston Bowel Preparation Score; SD: standard deviation.
The results of the first observation using WLI in the LCI and WLI groups are shown in Table 2. The numbers of adenoma and SSA/P in the LCI group and the WLI group were 35 and 31, respectively (p = 0.29). Regarding polyp location, the ratios of cecal location were 14.3% in the LCI group and 29.0% in the WLI group (p = 0.14). The ratios of polypoid morphology were 48.6% in the LCI group and 64.5% in the WLI group (p = 0.19). Histology showed that the ratios of adenomas were 88.6% in the LCI group and 80.6% in the WLI group (p = 0.37). ASDRs of the LCI and WLI groups were 30.7% and 32.3%, respectively (p = 0.85), and ADRs of the LCI and WLI groups were 26.2% and 26.2%, respectively (p = 1.0).
Table 2.
LCI 65 cases | WLI 65 cases | p value | |
---|---|---|---|
First observation Ad and SSA/P number, n |
35 | 31 | 0.29 |
Polyp size, mm, mean ± SD (range) |
4.8 ± 3.6 (2–20) |
4.0 ± 2.8 (2–15) |
0.30 |
Location, %, n C : A |
14.3 : 85.7 5 : 30 |
29.0 : 71.0 9 : 22 |
0.14 |
Morphology, %, n Polypoid: nonpolypoid |
48.6 : 51.4 17 : 18 |
64.5 : 35.5 20 : 11 |
0.19 |
Histology Ad : SSA/P |
88.6 : 11.4 31 : 4 |
80.6 : 19.4 25 : 6 |
0.37 |
First observation ASDR, %, n |
30.7 20 |
32.3 21 |
0.85 |
First observation ADR, %, n |
26.2 17 |
26.2 17 |
1.00 |
LCI: linked color imaging; WLI: white light; Ad: adenoma; SSA/P: sessile serrated adenoma and polyp; C: cecum; A: ascending colon; ASDR: adenoma and SSA/P detection rate; ADR: adenoma detection rate; SD: standard deviation.
The results of the 30 sec second observation using LCI or WLI are shown in Table 3. The numbers of adenoma and SSA/P in the LCI and WLI groups were 13 and 5, respectively (p = 0.04) (Figures 2 and 3). Polyp numbers in cases with BBPS 0 or 1 were 1 in the LCI group and 1 in the WLI group (p = 0.92). Regarding the comparison between LCI and WLI, there were no differences between polyp sizes (mm) (5.6 ± 4.1 versus 2.2 ± 0.4, p = 0.33), the ratio of cecal location (23.1% versus 40.0%, p = 0.37), the ratio of polypoid morphology (38.5% versus 60.0%, p = 0.52), and the ratio of adenoma histology (92.3% versus 100.0%, p = 0.91). ASDRs of LCI and WLI were 18.5% and 6.1%, respectively (p = 0.03), and ADRs of LCI and WLI were 16.9% and 6.1%, respectively (p = 0.05).
Table 3.
LCI 65 cases | WLI 65 cases | p value | |
---|---|---|---|
Second observation Ad and SSA/P number, n | 13 | 5 | 0.04 |
Polyp number in cases with BBPS 0 or 1 in first observation | 1 | 1 | 0.92 |
Polyp size, mm, mean ± SD (range) |
5.6 ± 4.1 (2.0–15.0) |
2.2 ± 0.4 (2.0–3.0) |
0.33 |
Location, %, n C : A |
23.1 : 76.9 3 : 10 |
40.0 : 60.0 2 : 3 |
0.37 |
Morphology, %, n Polypoid : nonpolypoid |
38.5 : 61.5 5 : 8 |
60.0 : 40.0 3 : 2 |
0.52 |
Histology Ad : SSA/P |
92.3 : 7.7 12 : 1 |
100.0 : 0 5 : 0 |
0.91 |
Second observation ASDR, %, n |
18.5 12 |
6.1 4 |
0.03 |
Second observation ADR, %, n |
16.9 11 |
6.1 4 |
0.05 |
LCI: linked color imaging; WLI: white light; Ad: adenoma; SSA/P: sessile serrated adenoma and polyp; C: cecum; A: ascending colon; ASDR: adenoma and SSA/P detection rate; ADR: adenoma detection rate; SD: standard deviation.
The overall results of the first and second observations are shown in Table 4. The overall adenoma and SSA/P numbers in the first and second observations were 48 in the LCI group and 36 in the WLI group, respectively (p = 0.02). Additionally, the overall adenoma numbers of the first and second observations were 43 in the LCI group and 30 in the WLI group, respectively (p = 0.02). The overall ASDRs of the LCI and WLI groups were 43.1 and 35.4, respectively (p = 0.36), and the overall ADRs of the LCI and WLI groups were 36.9 and 30.8 (p = 0.45), respectively. Regarding the LCI group, the numbers of adenoma and SSA/P in the first and second observations were significantly higher than in the first observation (48 versus 35, p = 0.017) though there was no significant difference about that in the WLI group (36 versus 31, p = 0.38). The second observation with LCI also increased ASDR from 30.7% to 43.1% and increased ADR from 26.2% to 36.9%, but there were no significant differences between the first observation and the first + second observations (p = 0.14, p = 0.18).
Table 4.
LCI 65 cases |
WLI 65 cases |
p value | |
---|---|---|---|
Overall Ad and SSA/P numbers in the first and second observations | 48 | 36 | 0.02 |
Overall Ad numbers in the first and second observations | 43 | 30 | 0.02 |
Overall ASDR, %, n | 43.1 28 |
35.4 23 |
0.36 |
Overall ADR, %, n | 36.9 24 |
30.8 20 |
0.45 |
LCI: linked color imaging; WLI: white light; Ad: adenoma; SSA/P: sessile serrated adenoma and polyp; ASDR: adenoma and SSA/P detection rate; ADR: adenoma detection rate.
4. Discussion
In our study, a 30 sec additional observation with LCI could improve overall adenoma and SSA/P numbers and overall adenoma numbers significantly more than those detected with WLI. Additionally, it significantly increased the adenoma and SSA/P numbers than the numbers in the first observation.
Our previous randomized controlled multicenter study conducted at 8 Japanese academic institutions showed that BLI-bright (489 cases) improved the mean number of adenomatous polyps detected per patient in comparison to WLI (474 cases) (1.27 ± 1.73 versus 1.01 ± 1.36, p = 0.008) and also improved the mean number of total polyps per patient in comparison to WLI (1.84 ± 2.09 versus 1.43 ± 1.64, p = 0.001) [11]. However, an observation using BLI-bright is not widely accepted. One of the reasons is that BLI-bright required longer observation times than WLI did (9.5 ± 3.8 min versus 8.4 ± 2.9 min, p < 0.001). The other reason is that BLI-bright is less bright than WLI and the reddish residual liquid in BLI-bright may become a disadvantage. Generally, poor preparation is detected in 20–25% of all colonoscopies [20, 21]. In those cases, BLI-bright is no more useful than WLI. As our case presentation showed, residual liquid disturbed the observation in BLI-bright. Additionally, NBI is not useful in poor preparations due to the same reasons, although current NBI systems and endoscopes showed positive results for polyp detection compared to the previous ones [22–24]. However, residual liquid is not reddish in LCI compared to BLI-bright. Thus, we suspect that LCI may be more useful for polyp detection than BLI-bright. In fact, a multicenter study from China proved that LCI increased ADR (LCI versus WLI: 37% versus 28%; 95% confidence interval, 2.3%–19.4%) [25]. The study also revealed that LCI significantly improved the rate of adenoma and SSA/P detected, more than WLI did (91% versus 73%, p < 0.001).
Our previous study showed that LCI improved polyp visibility more than WLI and BLI-bright did [13]. In brief, we used our original polyp visibility score (score 1: poor visibility, score 4: excellent visibility) and evaluated recorded short movies using LCI, BLI-bright, and WLI in 101 colorectal polyps. The mean polyp visibility scores of LCI were higher than those of WLI (2.86 ± 1.08 versus 2.54 ± 1.15, p < 0.001) and were also higher than those of BLI-bright (2.86 ± 1.08 versus 2.73 ± 1.47, p < 0.001). Additionally, LCI decreased the number of polyps detected showing poorer polyp visibility scores (score 1 or 2) than WLI did (experts: 35.6% versus 49.6%, p < 0.015; nonexperts: 33.6% versus 50.5%, p = 0.046). A similar study using polyp visibility scores showed that LCI improved the endoscopic visualization of nongranular colorectal lesions [26]. It also showed the efficacy of LCI for SSA/P. Moreover, our previous study showed the efficacies of LCI for nonpolypoid tumors and SSA/P [13]. Another study of ours showed the efficacy of LCI for diminutive polyps less than 5 mm in size [14]. In the study, color difference values between the tumor and the surrounding mucosa were calculated among endoscopic figures of 54 colorectal polyps taken by WLI and LCI for evaluating polyp visibility. Color difference value is thought as an objective indicator for polyp visibility. The study showed that LCI improved color difference values more than WLI did (33.6 ± 13.9 versus 20.7 ± 13.6, p < 0.001).
LCI presents the problem of halation in the endoscopic view due to its powerful brightness, which could lead to missed polyps, although it did not affect the results in the current study. The multicenter crossover study using LCI and WLI from China showed that there were 12 adenomas which were not detected in LCI, but were detected in WLI among 150 total adenomas [25]. Additionally, there were 29 polyps which were not detected in LCI, but were detected in WLI among 308 total polyps. We suggested that these outcomes were partially due to the powerful brightness of LCI. Missed polyps due to LCI should be examined in detail. However, the additional 30-second 2nd observation proposed in our study did not confer any additional risk of missed polyps due to LCI, because LCI is only used for second observations. In spite of this short 2nd observation time with LCI, it significantly increased the adenoma and SSA/P numbers than the numbers in the first observation. It also increased ASDR from 30.7% to 43.1% and increased ADR from 26.2% to 36.9% though it did not show significant difference (p = 0.14, p = 0.18).
Regarding serrated polyps, there are three types of polyps such as hyperplastic polyp, traditional serrated adenoma (TSA), and SSA/P [27]. TSA and SSA/P have an increased risk of progression to colorectal cancer [28, 29]. Thus, we analyzed not hyperplastic polyps but SSA/Ps in this study. Because of that, we could not calculate the polyp detection rate including hyperplastic polyps though most of previous similar studies did so.
There were some limitations in our study. This study was a parallel design without formal randomization, and a small number of patients were enrolled in two hospitals though the sample number was calculated statistically. Only three endoscopists performed all colonoscopies. There was a slight difference in the sedation rate between the WLI group and the LCI group though it was not significant. It might affect polyp detection. Though our study showed significant improvement in LCI about polyp detection in the study setting, more studies are needed to show whether this improvement is achieved in real-life settings.
5. Conclusions
Our study showed that a 30 sec additional observation with LCI significantly improved the number of adenoma and SSA/P in comparison to WLI. We think that our method will be easily accepted and is a less risky way for improving missed polyps.
Acknowledgments
The authors thank all the members of the Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, for their assistance with this study.
Data Availability
The data used to support the findings of this study are available from the corresponding author upon request.
Conflicts of Interest
Yoshito Itoh is affiliated with a donation-funded department from FUJIFILM Medical Co., Ltd. Yuji Naito and Naohisa Yoshida received a research grant from Fujifilm Corporation. The other authors have no conflicts of interest to declare.
References
- 1.Nishihara R., Wu K., Lochhead P., et al. Long-term colorectal-cancer incidence and mortality after lower endoscopy. The New England Journal of Medicine. 2013;369(12):1095–1105. doi: 10.1056/NEJMoa1301969. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Winawer S. J., Zauber A. G., Ho M. N., et al. Prevention of colorectal cancer by colonoscopic polypectomy. The New England Journal of Medicine. 1993;329(27):1977–1981. doi: 10.1056/NEJM199312303292701. [DOI] [PubMed] [Google Scholar]
- 3.Zauber A. G., Winawer S. J., O'Brien M. J., et al. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. The New England Journal of Medicine. 2012;366(8):687–696. doi: 10.1056/NEJMoa1100370. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Heresbach D., Barrioz T., Lapalus M. G., et al. Miss rate for colorectal neoplastic polyps: a prospective multicenter study of back-to-back video colonoscopies. Endoscopy. 2008;40(4):284–290. doi: 10.1055/s-2007-995618. [DOI] [PubMed] [Google Scholar]
- 5.Rex D. K., Cutler C. S., Lemmel G. T., et al. Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies. Gastroenterology. 1997;112(1):24–28. doi: 10.1016/S0016-5085(97)70214-2. [DOI] [PubMed] [Google Scholar]
- 6.Kim N. H., Jung Y. S., Jeong W. S., et al. Miss rate of colorectal neoplastic polyps and risk factors for missed polyps in consecutive colonoscopies. Intestinal Research. 2017;15(3):411–418. doi: 10.5217/ir.2017.15.3.411. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Lee J., Park S. W., Kim Y. S., et al. Risk factors of missed colorectal lesions after colonoscopy. Medicine. 2017;96(27, article e7468) doi: 10.1097/MD.0000000000007468. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Osawa H., Yamamoto H. Present and future status of flexible spectral imaging color enhancement and blue laser imaging technology. Digestive Endoscopy. 2014;26:105–115. doi: 10.1111/den.12205. [DOI] [PubMed] [Google Scholar]
- 9.Yoshida N., Hisabe T., Inada Y., et al. The ability of a novel blue laser imaging system for the diagnosis of invasion depth of colorectal neoplasms. Journal of Gastroenterology. 2014;49(1):73–80. doi: 10.1007/s00535-013-0772-7. [DOI] [PubMed] [Google Scholar]
- 10.Yoshida N., Hisabe T., Hirose R., et al. Improvement in the visibility of colorectal polyps by using blue laser imaging (with video) Gastrointestinal Endoscopy. 2015;82(3):542–549. doi: 10.1016/j.gie.2015.01.030. [DOI] [PubMed] [Google Scholar]
- 11.Kanzaki H., Takenaka R., Kawahara Y., et al. Linked color imaging (LCI), a novel image-enhanced endoscopy technology, emphasizes the color of early gastric cancer. Endoscopy International Open. 2017;5(10):E1005–E1013. doi: 10.1055/s-0043-117881. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Ikematsu H., Sakamoto T., Togashi K., et al. Detectability of colorectal neoplastic lesions using a novel endoscopic system with blue laser imaging: a multicenter randomized controlled trial. Gastrointestinal Endoscopy. 2017;86(2):386–394. doi: 10.1016/j.gie.2017.01.017. [DOI] [PubMed] [Google Scholar]
- 13.Yoshida N., Naito Y., Murakami T., et al. Linked color imaging improves the visibility of colorectal polyps: a video study. Endoscopy International Open. 2017;5(6):E518–E525. doi: 10.1055/s-0043-105495. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Yoshida N., Naito Y., Yasuda R., et al. Linked color imaging improves the visibility of various featured colorectal polyps in an endoscopist’s visibility and color difference value. International Journal of Colorectal Disease. 2017;32(9):1253–1260. doi: 10.1007/s00384-017-2855-z. [DOI] [PubMed] [Google Scholar]
- 15.Yamashina T., Takeuchi Y., Uedo N., et al. Diagnostic features of sessile serrated adenoma/polyps on magnifying narrow band imaging: a prospective study of diagnostic accuracy. Journal of Gastroenterology and Hepatology. 2015;30(1):117–123. doi: 10.1111/jgh.12688. [DOI] [PubMed] [Google Scholar]
- 16.Rex D. K., Kahi C., O'Brien M., et al. The American Society for Gastrointestinal Endoscopy PIVI (Preservation and Incorporation of Valuable Endoscopic Innovations) on real-time endoscopic assessment of the histology of diminutive colorectal polyps. Gastrointestinal Endoscopy. 2011;73(3):419–422. doi: 10.1016/j.gie.2011.01.023. [DOI] [PubMed] [Google Scholar]
- 17.Participants in the Paris Workshop. The Paris endoscopic classification of superficial neoplastic lesions: esophagus, stomach, and colon. Gastrointestinal Endoscopy. 2003;58(6):S3–S43. doi: 10.1016/S0016-5107(03)02159-X. [DOI] [PubMed] [Google Scholar]
- 18.Hamilton S. R., Aaltonen L. A., editors. World Health Organization Classification of Tumors. Pathology and Genetics of Tumours of the Digestive System. Lyon, France: IARC Press; 2010. [Google Scholar]
- 19.Yoshida N., Naito Y., Murakami T., et al. Safety and efficacy of a same-day low-volume 1 L PEG bowel preparation in colonoscopy for the elderly people and people with renal dysfunction. Digestive Diseases and Sciences. 2016;61(11):3229–3235. doi: 10.1007/s10620-016-4262-7. [DOI] [PubMed] [Google Scholar]
- 20.Froehlich F., Wietlisbach V., Gonvers J. J., Burnand B., Vader J. P. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study. Gastrointestinal Endoscopy. 2005;61(3):378–384. doi: 10.1016/S0016-5107(04)02776-2. [DOI] [PubMed] [Google Scholar]
- 21.Harewood G. C., Sharma V. K., de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointestinal Endoscopy. 2003;58(1):76–79. doi: 10.1067/mge.2003.294. [DOI] [PubMed] [Google Scholar]
- 22.Horimatsu T., Sano Y., Tanaka S., et al. Next-generation narrow band imaging system for colonic polyp detection: a prospective multicenter randomized trial. International Journal of Colorectal Disease. 2015;30(7):947–954. doi: 10.1007/s00384-015-2230-x. [DOI] [PubMed] [Google Scholar]
- 23.Adler A., Pohl H., Papanikolaou I. S., et al. A prospective randomised study on narrow-band imaging versus conventional colonoscopy for adenoma detection: does narrow-band imaging induce a learning effect? Gut. 2008;57(1):59–64. doi: 10.1136/gut.2007.123539. [DOI] [PubMed] [Google Scholar]
- 24.Rex D. K., Helbig C. C. High yields of small and flat adenomas with high-definition colonoscopes using either white light or narrow band imaging. Gastroenterology. 2007;133(1):42–47. doi: 10.1053/j.gastro.2007.04.029. [DOI] [PubMed] [Google Scholar]
- 25.Min M., Deng P., Zhang W., Sun X., Liu Y., Nong B. Comparison of linked color imaging and white-light colonoscopy for detection of colorectal polyps: a multicenter, randomized, crossover trial. Gastrointestinal Endoscopy. 2017;86(4):724–730. doi: 10.1016/j.gie.2017.02.035. [DOI] [PubMed] [Google Scholar]
- 26.Suzuki T., Hara T., Kitagawa Y., et al. Linked-color imaging improves endoscopic visibility of colorectal nongranular flat lesions. Gastrointestinal Endoscopy. 2017;86(4):692–697. doi: 10.1016/j.gie.2017.01.044. [DOI] [PubMed] [Google Scholar]
- 27.Snover D., Ahnen D., Burt R., Odze R. D. Serrated polyps of the colon and rectum and serrated polyposis. In: Bosman F., Cameiro F., Hruban R., Theise N. D., editors. World Health Organization Classification of Tumours. Tumors of the Digestive System. 4th. Lyon, France: International Agency for Research on Cancer (IARC) Press; 2010. pp. 160–165. [Google Scholar]
- 28.Snover D. C. Update on the serrated pathway to colorectal carcinoma. Human Pathology. 2011;42(1):1–10. doi: 10.1016/j.humpath.2010.06.002. [DOI] [PubMed] [Google Scholar]
- 29.Rex D. K., Ahnen D. J., Baron J. A., et al. Serrated lesions of the colorectum: review and recommendations from an expert panel. The American Journal of Gastroenterology. 2012;107(9):1315–1329. doi: 10.1038/ajg.2012.161. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data used to support the findings of this study are available from the corresponding author upon request.