Diabetes Device Use and Glycemic Control among Youth with Type 1 Diabetes: A Single-Center, Cross-Sectional Study

Khalid Sheikh 1, Sara K Bartz 2, Sarah K Lyons 2, Daniel J DeSalvo 2,
PMCID: PMC6087575  PMID: 30151393

Abstract

Aim

The purpose of this cross-sectional study was to determine the rates of diabetes device use (insulin pump and continuous glucose monitor (CGM)) and association with glycemic control in youth with type 1 diabetes in a large, diverse pediatric center.

Methods

Demographic and clinical data were obtained from 1992 patients who met the eligibility criteria (age < 26 years, diabetes duration ≥ 1 year, and ≥1 clinic visit in the preceding 12 months). Statistical analyses assessed the likelihood of device use based on demographic characteristics and the association between device use and glycemic control based on most recent hemoglobin A1c (HbA1c).

Results

Mean age was 13.8 ± 4.2 years, 50.7% were female, diabetes duration was 6.2 ± 4 years, and mean HbA1c was 8.7 ± 1.8%. Overall, 38.2% of patients were on pump therapy and 18.5% were on CGM. Patients who were non-Hispanic (NH) white, privately insured, and with primary English-speaking parent(s) had higher rates of insulin pump use, as well as CGM use (P < 0.001 for both). Female patients had higher rates of pump use only (P < 0.01). Private health insurance, NH white race/ethnicity, and CGM use were each associated with lower HbA1c (P = 0.03, <0.001, and <0.008, resp.).

Conclusion

At a large, diverse, pediatric diabetes center, disparities in diabetes device use were present across sex, race/ethnicity, health insurance coverage, and primary language of parent(s). CGM use was associated with lower HbA1c. Quality improvement efforts are underway to ensure improved access, education, and clinical programs for advanced diabetes devices for T1D patients.

1. Introduction

Intensive treatment of type 1 diabetes (T1D) leads to improved glycemic control resulting in reduced risk of microvascular complications [13]. Current American Diabetes Association (ADA) recommendations for pediatric patients with T1D are aimed at achieving near normal glycemia (HbA1c < 7.5% for children and <7.0% for young adults) while avoiding severe hypoglycemic events [4]; however, the vast majority of youth and young adults with T1D are not meeting glycemic targets. Fewer than 25% of pediatric patients in the T1D Exchange Registry, a US-based registry comprised of over 26,000 individuals with T1D, achieve the ADA-recommended HbA1c target [5].

Insulin pumps and continuous glucose monitors (CGM) are advanced diabetes management devices that may lead to improved glycemic control compared to traditional insulin injections with self-monitoring of blood glucose (SMBG) [611]. Compared to injections, insulin pump therapy offers a more physiologic method of insulin delivery by simulating the normal diurnal pattern of basal insulin secretion in conjunction with prandial or correction boluses [12]. CGM is an emerging technology that provides a continuous measure of interstitial fluid glucose levels to provide real-time trends and alerts to glucose excursions [13]. Despite their potential benefit for improving glycemic control, uptake of these technologies has been limited with 60% of T1D Exchange Registry participants using an insulin pump and a mere 11% using CGM [5].

In this study, we evaluated the rates of advanced diabetes device use and association with glycemic control among pediatric and young adult patients with T1D at Texas Children's Hospital (TCH)—a large, academic, tertiary urban hospital with a diverse patient population.

2. Methods

The study was approved by the Baylor College of Medicine Institutional Review Board. We deployed the EPIC® electronic medical record population health management system for the Texas Children's Hospital diabetes clinic patient registry to generate a comprehensive data report to perform a cross-sectional analysis. Recorded variables included age, sex, race/ethnicity, diabetes type, date of diagnosis, insurance coverage, primary spoken language of parent(s), insulin management category, use of CGM, and most recent HbA1c measurement. Medical insurance was classified as public for patients with coverage through Medicaid or Children's Health Insurance Program (CHIP). Eligibility criteria included patients < 26 years of age with a clinical diagnosis of T1D of at least 1-year duration with at least one diabetes clinic visit between July 1, 2015, and June 30, 2016.

2.1. Statistical Analysis

Fisher's exact test was used to compare the distribution of patient characteristics between those who use technology (CGM and/or insulin pump) and those who do not. The multiple logistic regression model including sex, primary language of parent(s), insurance type (public or private), and race/ethnicity was used to estimate the odds of not using pump therapy and not using CGM. A general linear model (least square means) was used to analyze significant associations between the predictor variables and HbA1c. Unadjusted HbA1c data was analyzed by t-test for 2-group comparisons and analysis of variance (ANOVA) for multiple-group comparisons. Data analyses were performed using SAS version 9.4 (2011 SAS Institute Inc., Cary, NC). Two-sided P values < 0.05 were considered statistically significant. Data are presented as mean ± standard deviation unless otherwise specified.

3. Results

A total of 1992 T1D patients met the criteria, with 50.7% female, mean age of 13.8 ± 4.2 years, duration of diabetes of 6.2 ± 4.0 years, and HbA1c of 8.7 ± 1.8% (Table 1).

Table 1.

Demographic characteristics of the 1992 T1D patients.

N (%)
Sex
Male 982 (49.3%)
Female 1010 (50.7%)
Age
2–6 years 70 (3.5%)
6–<13 years 629 (31.6%)
13–<18 years 905 (45.4%)
18–<26 years 388 (19.5%)
Race/ethnicity
Non-Hispanic white 1043 (52.4%)
Non-Hispanic black 334 (16.8%)
Hispanic 484 (24.3%)
Other 131 (6.6%)
Insurance type
Private 1325 (66.5%)
Public 639 (32.1%)
None 28 (1.4%)
Primary language of parent(s)
English 1836 (92.2%)
Spanish 156 (7.8%)

Overall, 761 (38.2%) patients were using an insulin pump and 369 (18.5%) were using CGM for diabetes management. Females were more likely to use insulin pumps than males (P < 0.01), while rates of CGM use were similar between males and females (P = 0.06). Non-Hispanic (NH) whites were more likely to use insulin pumps (P < 0.001) and CGM (P < 0.001) than minority patients. Patients with private health insurance were more likely to use insulin pumps (P < 0.001) and CGM (P < 0.001) than those with public health insurance or no insurance. Patients with English-speaking parent(s) were more likely to use insulin pumps (P < 0.001) and CGM (P < 0.001) than those with Spanish-speaking parent(s) (Table 2).

Table 2.

Comparison of patient characteristics between those who use diabetes device (pump/CGM) and those who do not.

Pump CGM
No (%) Yes (%) P value No (%) Yes (%) P value
Sex Female 585 (47.5) 425 (55.8) <0.001 806 (49.7%) 204 (55.3%) 0.057
Male 646 (52.5) 336 (44.2) 817 (50.3%) 165 (44.7%)

Race/ethnicity NH white 503 (40.9) 540 (71.0) <0.001 761 (46.9) 282 (76.4) <0.001
NH black 286 (23.2) 48 (6.3) 314 (19.3) 20 (5.4)
Hispanic 358 (29.1) 126 (16.6) 444 (27.4) 40 (10.8)
Other 84 (6.8) 47 (6.2) 104 (6.4) 27 (7.3)

Insurance type None 23 (1.9%) 5 (0.7%) <0.001 26 (1.6%) 2 (0.5%) <0.001
Private 712 (57.8%) 613 (80.6%) 973 (60.0%) 352 (95.4%)
Public 496 (40.3%) 143 (18.8%) 624 (38.4%) 15 (4.1%)

Primary language of parent(s) English 1098 (89.2%) 738 (97.0%) <0.001 1469 (90.5%) 367 (99.5%) <0.001
Spanish 133 (10.8%) 23 (3.0%) 154 (9.5%) 2 (0.5%)

In multiple logistic regression modeling, all variables maintained significant associations with pump use after simultaneously adjusting for the other variables in the model. The odds of not using a pump were greater among males (OR: 1.46; 95% CI: 1.20, 1.77), patients with Spanish-speaking parent(s) (OR: 2.27; 95% CI: 1.36, 3.78), and those with public health insurance (OR: 1.97; 95% CI: 1.54, 2.54). The odds of not using a pump were also greater among Hispanics (OR: 1.82; 95% CI: 1.37, 2.40) and NH blacks (OR: 5.37; 95% CI: 3.83, 7.54) than among NH whites (Figure 1(a)).

Figure 1.

Figure 1

(a) Odds ratios of not using an insulin pump (95% confidence intervals). (b) Odds ratios of not using CGM (95% confidence intervals).

Similarly, all variables maintained statistically significant associations with CGM use after simultaneously adjusting for the other variables in the model. The odds of not using CGM were greater among males (OR: 1.32; 95% CI: 1.03, 1.69), patients with Spanish-speaking parent(s) (OR: 6.59; 95% CI: 1.51, 28.73), and those with public insurance (OR: 11.59; 95% CI: 6.72, 19.99). The odds of not using CGM were also greater among Hispanics (OR: 1.62; 95% CI: 1.09, 2.40) and NH blacks (OR: 4.06; 95% CI: 2.48, 6.66) than among NH whites (Figure 1(b)).

In the general linear model (least square means) analyzing the association between predictor variables and HbA1c, private health insurance (P = 0.003) and NH whites (P < 0.001) were associated with lower HbA1c estimates after simultaneously adjusting for all variables in the model. Neither sex nor primary language of parents was found to have a difference in HbA1c estimate. CGM use was associated with lower HbA1c estimate (P < 0.008), but pump use was not (P = 0.295) (Table 3).

Table 3.

Association between patient characteristics and HbA1C.

HbA1c estimate Standard error Lower Upper P value
Sex Female 8.9 0.18 8.6 9.3 P = 0.525
Male 8.9 0.19 8.5 9.2

Race/ethnicity NH white 8.5 0.19 8.2 8.9 P < 0.001
NH black 9.6 0.20 9.3 10.0
Hispanic 8.9 0.18 8.5 9.2
Other 8.6 0.23 8.1 9.0

Insurance type None 8.6 0.35 7.9 9.3 P = 0.003
Private 8.9 0.15 8.6 9.2
Public 9.2 0.16 8.9 9.5

Primary language English 9.0 0.17 8.7 9.3 P = 0.234
Spanish 8.8 0.23 8.4 9.2

Pump use No 9.0 0.19 8.6 9.4 P = 0.295
Yes 8.8 0.22 8.4 9.2

CGM use No 9.1 0.18 8.7 9.4 P = 0.008
Yes 8.7 0.21 8.3 9.1

In the analysis of unadjusted HbA1c data, publicly insured patients had higher mean HbA1c than privately insured patients (9.1 ± 2.0% versus 8.4 ± 1.6%, P ≤ 0.001); however, this difference was not seen between publicly insured pump users and privately insured pump users (8.5 ± 1.5% versus 8.3 ± 1.4%, P = 0.279) (Figure 2).

Figure 2.

Figure 2

(a) Unadjusted HbA1c data by insurance type. (b) Unadjusted HbA1c data for insurance type analyzed by diabetes treatment regimen stratified by pump and/or CGM use. ∗∗∗ indicates P < 0.001; ns indicates not statistically significant.

4. Discussion

This single-center, cross-sectional study analyzed the associations between diabetes device use and demographic factors in pediatric and young adult patients with T1D and between device use and glycemic control. In our large, diverse, pediatric diabetes center, differences in diabetes device use were present for sex, race/ethnicity, health insurance coverage, and primary language of parent(s).

Disparities in device use and glycemic control were found between Hispanic and NH black patients compared to NH white patients. These racial/ethnic differences are in line with studies reporting lower rates of device use for Hispanic and NH black patients compared to NH white patients [1416]. The previous study suggested that racial/ethnic disparities in diabetes device use may be perpetuated by subconscious racial stereotyping by providers assessing minority patients' preparedness for diabetes devices [16].

Disparities in rates of device use and glycemic control were also present between patients with Spanish-speaking parent(s) compared to those with English-speaking parent(s). The previous study reported language barrier as a contributing factor to low diabetes device use, possibly due to inadequate education regarding the benefits of these technologies [17]. Notably, patients who are Hispanic and have Spanish-speaking parents face two potential barriers (minority status and language) to diabetes device uptake. In effort to improve rates of diabetes device use, our diabetes center has recently developed comprehensive education materials, available in both Spanish and English. The clinic also employs bilingual certified diabetes educators proficient in Spanish to deliver the education to Spanish-speaking families.

Previous studies have reported that socioeconomic status impacts diabetes device use due to financial concerns of families [15, 18]. The difference in rates of diabetes device use between patients with private and public health insurance at our institution was striking. In Texas, public insurance programs including Medicaid and CHIP provide comprehensive coverage for insulin pump therapy but not currently for CGM devices. Therefore, the large disparity in pump use between publicly and privately insured patients was unexpected and suggests that affordability may not be the primary barrier to diabetes device use. The disparities in device use may be due to unmeasured variables such as patient preference or provider biases in interpreting patients' device preparedness. The recent study reported that patients with private insurance have better glycemic control than patients with public insurance [19]. Results from the analysis of our unadjusted data suggest that insulin pump use may mitigate the difference in HbA1c found between patients on public and private insurance; however, the cross-sectional study design does not determine the causality of pump use in lowering HbA1c.

Our finding that CGM use was associated with improved glycemic control (lower mean HbA1c) is consistent with numerous studies [2024]. CGM provides patients with a real-time view of the glucose level and trends to augment diabetes treatment decisions on a frequent basis to optimize glycemic control. Additionally, downloading CGM data provides a comprehensive pattern of glycemic trends, allowing providers to make more informed adjustments in insulin regimens [13]. Our findings suggest that CGM use may be more effective in improving glycemic control (lower HbA1c) than insulin pump therapy alone. This suggests that if choosing between one device and the other, CGM may be preferred initially. The introduction of two devices at once may add to the overwhelming feeling in diabetes management, especially in newly diagnosed patients [24, 25], so introducing patients to CGM first may lead to improvements in glycemic control while limiting burden of disease on the patient and family. Eventually transitioning patients to sensor-augmented pump therapy may allow patients to benefit from both devices.

Our study has multiple limitations. A major limitation is its cross-sectional design, which does not allow determination of causality of device use with glycemic control. Although we found a correlation between CGM use and lower HbA1c, we were unable to measure the effect of wear time on CGM efficacy. This is a notable limitation since previous studies report that duration of CGM is positively related to reduction in HbA1c [9, 22, 26, 27]. An additional limitation is that our analyses did not include parental income or the level of education, which are important factors in diabetes device use [1416].

Our findings reveal a myriad of potential barriers in utilizing diabetes devices that may assist patients in achieving optimal glycemic control. Many patients face multiple barriers in device uptake (i.e., minority status, insurance coverage, and language), placing them at further disadvantage in initiating pump therapy and/or CGM. Innovative quality improvement efforts, clinical programs, and research interventions must be implemented to overcome potential barriers to diabetes device use and thereby allow more patients to achieve improved glycemic control.

5. Conclusion

Differences in rates of diabetes device use were present across sex, race/ethnicity, health insurance coverage, and primary spoken language of parents. The use of CGM was associated with improved glycemic control (lower HbA1c), more so than insulin pump therapy. Strategies to effectively increase and utilize advanced diabetes devices among T1D patients of all race/ethnicities, insurance types, and languages could substantially improve clinical outcomes. To this end, quality improvement efforts are underway at our center to ensure improved access, education, and clinical programs for advanced diabetes devices for T1D patients.

Acknowledgments

The authors wish to thank the Baylor College of Medicine Institute for Clinical and Translational Research for providing statistical support for this study. Khalid Sheikh received research funding from the Houston Scholars Program at the University of Houston, which was supported by the Provost's Office and the Honors College. The Section of Pediatric Diabetes & Endocrinology at Baylor College of Medicine/Texas Children's Hospital provided funding for the bistatistical support for this study.

Data Availability

The authors agree to make our deidentified dataset available by request, immediately upon publication.

Conflicts of Interest

The authors declare that the funding did not lead to any conflict of interest regarding the publication of this manuscript. Dr. Daniel J. DeSalvo has received honorariums as an advisor to Dexcom (CGM company) and Insulet (maker of the Omnipod insulin pump); however, neither of these products is mentioned or endorsed in the manuscript.

References

  • 1.Nathan D. M., Genuth S., Lachin J., et al. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. The New England Journal of Medicine. 1993;329(14):977–986. doi: 10.1056/nejm199309303291401. [DOI] [PubMed] [Google Scholar]
  • 2.Nathan D. M., Cleary P. A., Backlund J. Y., et al. Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. The New England Journal of Medicine. 2005;353(25):2643–2653. doi: 10.1056/NEJMoa052187. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Fullerton B., Jeitler K., Seitz M., Horvath K., Berghold A., Siebenhofer A. Intensive glucose control versus conventional glucose control for type 1 diabetes mellitus. Cochrane Database of Systematic Reviews. 2014;(2, article CD009122) doi: 10.1002/14651858.CD009122.pub2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.American Diabetes Association. 6. Glycemic targets: standards of medical care in diabetes—2018. Diabetes Care. 2018;41(Supplement 1):S55–S64. doi: 10.2337/dc18-S006. [DOI] [PubMed] [Google Scholar]
  • 5.Miller K. M., Foster N. C., Beck R. W., et al. Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D exchange clinic registry. Diabetes Care. 2015;38(6):971–978. doi: 10.2337/dc15-0078. [DOI] [PubMed] [Google Scholar]
  • 6.Johnson S. R., Cooper M. N., Jones T. W., Davis E. A. Long-term outcome of insulin pump therapy in children with type 1 diabetes assessed in a large population-based case-control study. Diabetologia. 2013;56(11):2392–2400. doi: 10.1007/s00125-013-3007-9. [DOI] [PubMed] [Google Scholar]
  • 7.Pickup J. C., Sutton A. J. Severe hypoglycaemia and glycaemic control in type 1 diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion. Diabetic Medicine. 2008;25(7):765–774. doi: 10.1111/j.1464-5491.2008.02486.x. [DOI] [PubMed] [Google Scholar]
  • 8.Beck R. W., Hirsch I. B., Laffel L., et al. The effect of continuous glucose monitoring in well-controlled type 1 diabetes. Diabetes Care. 2009;32:1378–1383. doi: 10.2337/dc09-0108. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Deiss D., Bolinder J., Riveline J. P., et al. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care. 2006;29(12):2730–2732. doi: 10.2337/dc06-1134. [DOI] [PubMed] [Google Scholar]
  • 10.Rachmiel M., Landau Z., Boaz M., et al. The use of continuous glucose monitoring systems in a pediatric population with type 1 diabetes mellitus in real-life settings: the AWeSoMe study group experience. Acta Diabetologica. 2015;52(2):323–329. doi: 10.1007/s00592-014-0643-6. [DOI] [PubMed] [Google Scholar]
  • 11.Karges B., Schwandt A., Heidtmann B., et al. Association of insulin pump therapy vs insulin injection therapy with severe hypoglycemia, ketoacidosis, and glycemic control among children, adolescents, and young adults with type 1 diabetes. JAMA. 2017;318(14):1358–1366. doi: 10.1001/jama.2017.13994. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Pickup J. C. Insulin-pump therapy for type 1 diabetes mellitus. The New England Journal of Medicine. 2012;366(17):1616–1624. doi: 10.1056/NEJMct1113948. [DOI] [PubMed] [Google Scholar]
  • 13.DeSalvo D., Buckingham B. Continuous glucose monitoring: current use and future directions. Current Diabetes Reports. 2013;13(5):657–662. doi: 10.1007/s11892-013-0398-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Willi S. M., Miller K. M., DiMeglio L. A., et al. Racial-ethnic disparities in management and outcomes among children with type 1 diabetes. Pediatrics. 2015;135(3):424–434. doi: 10.1542/peds.2014-1774. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Paris C. A., Imperatore G., Klingensmith G., et al. Predictors of insulin regimens and impact on outcomes in youth with type 1 diabetes: the SEARCH for Diabetes in Youth study. The Journal of Pediatrics. 2009;155(2):183–189.e1. doi: 10.1016/j.jpeds.2009.01.063. e181. [DOI] [PubMed] [Google Scholar]
  • 16.Valenzuela J. M., La Greca A. M., Hsin O., Taylor C., Delamater A. M. Prescribed regimen intensity in diverse youth with type 1 diabetes: role of family and provider perceptions. Pediatric Diabetes. 2011;12(8):696–703. doi: 10.1111/j.1399-5448.2011.00766.x. [DOI] [PubMed] [Google Scholar]
  • 17.Nam S., Chesla C., Stotts N. A., Kroon L., Janson S. L. Barriers to diabetes management: patient and provider factors. Diabetes Research and Clinical Practice. 2011;93(1):1–9. doi: 10.1016/j.diabres.2011.02.002. [DOI] [PubMed] [Google Scholar]
  • 18.Commissariat P. V., Boyle C. T., Miller K. M., et al. Insulin pump use in young children with type 1 diabetes: sociodemographic factors and parent-reported barriers. Diabetes Technology & Therapeutics. 2017;19(6):363–369. doi: 10.1089/dia.2016.0375. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Clements M. A., Foster N. C., Maahs D. M., et al. Hemoglobin A1c (HbA1c) changes over time among adolescent and young adult participants in the T1D exchange clinic registry. Pediatric Diabetes. 2016;17(5):327–336. doi: 10.1111/pedi.12295. [DOI] [PubMed] [Google Scholar]
  • 20.Klonoff D. C., Ahn D., Drincic A. Continuous glucose monitoring: a review of the technology and clinical use. Diabetes Research and Clinical Practice. 2017;133:178–192. doi: 10.1016/j.diabres.2017.08.005. [DOI] [PubMed] [Google Scholar]
  • 21.Ahn D., Pettus J., Edelman S. Unblinded CGM should replace blinded CGM in the clinical management of diabetes. Journal of Diabetes Science and Technology. 2016;10(3):793–798. doi: 10.1177/1932296816632241. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Effectiveness of continuous glucose monitoring in a clinical care environment: evidence from the Juvenile Diabetes Research Foundation continuous glucose monitoring (JDRF-CGM) trial. Diabetes Care. 2010;33(1):17–22. doi: 10.2337/dc09-1502. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Pickup J. C., Freeman S. C., Sutton A. J. Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data. BMJ. 2011;343(jul07 1):p. d3805. doi: 10.1136/bmj.d3805. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Langendam M., Luijf Y. M., Hooft L., Devries J. H., Mudde A. H., Scholten R. J. Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database of Systematic Reviews. 2012;1 doi: 10.1002/14651858.cd008101. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Chiang J. L., Kirkman M. S., Laffel L. M., Peters A. L., Type 1 Diabetes Sourcebook Authors Type 1 diabetes through the life span: a position statement of the American Diabetes Association. Diabetes Care. 2014;37(7):2034–2054. doi: 10.2337/dc14-1140. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Tamborlane W. V., Beck R. W., Bode B. W., et al. Continuous glucose monitoring and intensive treatment of type 1 diabetes. The New England Journal of Medicine. 2008;359(14):1464–1476. doi: 10.1056/NEJMoa0805017. [DOI] [PubMed] [Google Scholar]
  • 27.Raccah D., Sulmont V., Reznik Y., et al. Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: the RealTrend study. Diabetes Care. 2009;32(12):2245–2250. doi: 10.2337/dc09-0750. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The authors agree to make our deidentified dataset available by request, immediately upon publication.


Articles from Journal of Diabetes Research are provided here courtesy of Wiley