Abstract
Background
Sepsis-induced myocardial dysfunction is associated with poor outcomes, but traditional measurements of systolic function such as left ventricular ejection fraction (LVEF) do not directly correlate with prognosis. Global longitudinal strain (GLS) utilizing speckle-tracking echocardiography (STE) could be a better marker of intrinsic left ventricular (LV) function, reflecting myocardial deformation rather than displacement and volume changes. We sought to investigate the prognostic value of GLS in patients with sepsis and/or septic shock.
Methods
We conducted a systematic review (PubMed and Embase up to 26 October 2017) and meta-analysis to investigate the association between GLS and mortality at longest follow up in patients with severe sepsis and/or septic shock. In the primary analysis, we included studies reporting transthoracic echocardiography data on GLS according to mortality. A secondary analysis evaluated the association between LVEF and mortality including data from studies reporting GLS.
Results
We included eight studies in the primary analysis with a total of 794 patients (survival 68%, n = 540). We found a significant association between worse LV function and GLS values and mortality: standard mean difference (SMD) − 0.26; 95% confidence interval (CI) − 0.47, − 0.04; p = 0.02 (low heterogeneity, I2 = 43%). No significant association was found between LVEF and mortality in the same population of patients (eight studies; SMD, 0.02; 95% CI − 0.14, 0.17; p = 0.83; no heterogeneity, I2 = 3%).
Conclusions
Worse GLS (less negative) values are associated with higher mortality in patients with severe sepsis or septic shock, while such association is not valid for LVEF. More critical care research is warranted to confirm the better ability of STE in demonstrating underlying intrinsic myocardial disease compared to LVEF.
Electronic supplementary material
The online version of this article (10.1186/s13054-018-2113-y) contains supplementary material, which is available to authorized users.
Keywords: Global longitudinal strain, Intensive care, Left ventricular ejection fraction, Speckle tracking, Systolic dysfunction
Background
A recent expert consensus updated the definition of sepsis as “life-threatening organ dysfunction caused by a dysregulated host response to infection” [1]. The response to the infective process can cause profound hemodynamic alterations, leading to organ dysfunction and accounting for high mortality and morbidity [2, 3]. The most severe manifestation of sepsis is septic shock, a condition characterized not only by vasoplegia but that can also present with myocardial depression. Septic cardiomyopathy is the widely used term for myocardial involvement in sepsis [4], and can present with left and/or right ventricular (LV and/or RV) impairment [5]. The majority of patients with sepsis and/or septic shock have underlying cardiac dysfunction as demonstrated by a post-mortem necropsy study that showed myocardial injury in more than half of patients with sepsis and/or septic shock [6], although such patients do not always exhibit signs and symptoms of myocardial ischemia [7].
While there is growing evidence of an association between LV diastolic dysfunction and mortality [8, 9], the influence of LV systolic dysfunction (LVSD) is less clear. Initial evidence suggested that mean LV ejection fraction (LVEF, the most commonly used index to define LVSD) is paradoxically higher in non-survivors of septic shock [10], although this association has not been subsequently confirmed [11]. Finally, a meta-analysis showed no association between LVEF and mortality in a septic population [12], and this has been confirmed by subsequent work [8].
Echocardiography is currently suggested as part of the first-line approach in the evaluation of patients with shock [13], but the use of conventional indexes of systolic function in patients with sepsis and/or septic shock may not accurately reflect the true systolic function. Traditional estimation of LVSD is problematic in sepsis since LVEF is based on significant geometric assumptions and is also highly dependent on loading conditions. Preload is highly variable according to fluid and vasoactive drug resuscitation, degree of endothelial insult and vascular leak. Afterload variations in sepsis (vasoplegia and vasoconstrictor use) causes changes in LVEF that are not necessarily related to true variations in intrinsic myocardial contractility [14].
An alternative echocardiographic modality, speckle-tracking echocardiography (STE) is emerging as a better marker of intrinsic LV function [15]. It was first described in 2004 as an angle-independent non-Doppler method [16], based on the generation of ultrasound echoes (“speckles”) representing discrete myocardial areas tracked throughout the cardiac cycle [17]. Strain represents the difference between the final length of each segment relative to its resting length and can be measured in different planes: longitudinal (from base to apex), radial (inward short axis), and circumferential (rotational short axis). Its assessment is performed during bedside echocardiography, and global longitudinal strain (GLS) is the most commonly reported strain measure, representing the ratio of the maximal change in the myocardial longitudinal length in systole to the original length in diastole. In short, more negative values of GLS indicate better LV systolic function. The conceptual difference between assessment of myocardial function with GLS or LVEF is illustrated in Fig. 1.
In this systematic review and meta-analysis we aim to investigate the association between values of strain and mortality in patients with severe sepsis and/or septic shock. We hypothesize that GLS, but not LVEF values, are associated with mortality in patients suffering from severe sepsis and/or septic shock.
Methods
This systematic review and meta-analysis was performed in accordance with preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines [18]. The review was registered with the international prospective register of systematic reviews (PROSPERO, number CRD 42016041712).
Eligibility criteria
Since the definition of sepsis and septic shock changed only recently, we included in our meta-analysis prospective studies providing data on mortality of patients with severe sepsis and/or septic shock, as defined by the previously widely accepted international consensus [19]. Studies with non-prospective design were included in sensitivity analyses.
Studies were included in the analysis if they provided values for strain echocardiography in survivors and non-survivors in a population including patients with severe sepsis and/or septic shock. In the event of studies reporting only the overall population strain values, we contacted the authors to increase data availability. Inclusion criteria were pre-specified using the patient, population or problem, intervention, comparison, outcomes and study design (or setting) (PICOS) framework (Table 1). Pediatric populations were excluded to minimize heterogeneity. Only case series reporting LVSD data and outcomes from at least 10 patients were included.
Table 1.
PICOS | Characteristics of clinical studies included for the qualitative synthesis and meta-analysis |
---|---|
1. Participants | Adult patients with severe sepsis and/or septic shock |
2. Intervention | Strain echocardiographic assessment with TTE, conducted within the first 48 h from diagnosis |
3. Comparison | Primary: comparison of GLS values between survivors and non-survivors Secondary: comparison of LVEF between survivors and non-survivors (only studies providing GLS) Sensitivity: leave-one-out-at-a-time, excluding studies with high risk of bias, including studies performing TTE within 1 week; including retrospective and case-control studies |
4. Outcomes | Mortality (at longest follow-up available) |
5. Study design | Prospective clinical studies |
PICOS patient, population or problem, intervention, comparison, outcomes and study design (or setting), GLS global longitudinal strain, LVEF left ventricular ejection fraction, TTE trans-thoracic echocardiography
Identification of studies
A systematic search of the electronic databases - MEDLINE (PubMed) and EMBASE - was performed through the National Health Service (NHS) Healthcare Databases Advanced Search. Relevant titles were also identified by hand-searching reviews on the topic and exploring the list of the references of the selected papers. There was no date restriction and only articles published in English, Spanish, French, German or Italian were considered. Duplicates were filtered through automated function and then manually searched. Titles retrieved from EMBASE as conference abstracts were considered only if published after October 2015 to allow a reasonable time for adequate peer review. The last search update was on 26 October 2017.
The findings of two search-term groups were combined: the items “bacteraemia”, “bacteremia”, “respiratory distress syndrome”, “sepsis”, “septic shock”, “severe sepsis” and “systemic inflammatory response” were used for the first group; “strain echocardiography”, “global longitudinal strain” or “global circumferential strain” for the second group. The flow of references was managed with the Endnote X7 citation manager.
Analysis of outcomes
The primary outcome was the relationship between GLS values of survivors and non-survivors from the cohort of patients with sepsis and/or septic shock and mortality at longest follow up, since most studies were expected to report mortality at several time intervals. From the studies reporting GLS values, we also assessed the difference in LVEF between surviving and non-surviving patients with sepsis and/or septic shock as the secondary outcome of our meta-analysis.
Five sensitivity analyses were planned: the first was conducted excluding studies with high risk of bias, the second using the “leave-one-out-at-a-time” approach, the third including data from studies providing data on patients later than 48 h after the diagnosis, the fourth including retrospective and case-control studies and the fifth grouping studies according to the software used for GLS assessment.
Study selection and data extraction
Three investigators (FS, CC and AA) independently screened titles and abstracts produced by the search and identified potentially relevant articles. Full-text articles that were identified as relevant were then assessed against the eligibility criteria. Discrepancies were resolved by consensus and/or by involving other authors (MC, AVB and NF).
Two reviewers (FS and CC) independently extracted data from individual studies, contacted corresponding authors and entered information into a pre-designed data collection form. Data extracted from each study included the number of patients with sepsis and/or septic shock examined, the number of patients mechanically ventilated, the sequential organ failure assessment (SOFA) score and the longest follow-up mortality data, as shown in Table 2. All the authors conducted also an independent search on Medline to check for further evidence.
Table 2.
Author, year population (number) |
Echocardiography timing | GLS software and TTE views used | Data reported | SAPS SOFA APACHE |
MV | Mortality | Longest follow up |
---|---|---|---|---|---|---|---|
Boissier, 2017 78 ICU patients with septic shock |
TTE within 24 h of ICU admission | Philips’ Qlab 8.1 (Philips®) Ap: 4ch, 2ch |
GLS and LVEF | 60.1 ± 20.5 11.7 ± 3.4 - |
84.6% | 43.6% | Hospital |
Chang, 2015 111 ICU patients with septic shock |
TTE within 24 h of ICU admission | EchoPAC v. BT09 (GE®) Ap: 4ch, 2ch, 3ch |
GLS and LVEF | - - 21 ± 8 |
65.8% | 35.1% | Hospital |
De Geer, 2014 50 ICU patients with septic shock |
TTE within 24 h of ICU admission | EchoPac v. 112 (GE®) Ap: 4ch, 2ch, 3ch |
GLS and LVEF | - 11 (9–12) - |
84% | 34% | 90-day |
Innocenti, 2016 56 ED patients with septic shock |
TTE within 24 h if ICU admission | Philips’ Qlab 8.1 (Philips®) Ap: 4ch, 2ch |
GLS and LVEF | - 6.3 ± 2.8 - |
– | 27.2% | 28-day |
Landesberg, 2014 106 ICU patients with severe sepsis or septic shock |
TTE on ICU admission day or as soon as possible | Philips’ Qlab 8.1 (Philips®) Ap: 4ch, 2ch |
GLS and LVEF | - - 21.61 ± 6.8 |
100% | 39% | Hospital |
Lanspa, 2017 298 ICU patients with severe sepsis or septic shock |
TTE within 24 h of ICU admission | Image-Arena platform (TomTec®) Ap: 4ch |
GLS | - 9 (6–12) 25 (18–23) |
– | 23% | 28-day |
Orde, 2014 60 adult patients with severe sepsis or septic shock |
TTE within 24 h of meeting severe sepsis criteria | Syngo Velocity Vector Imaging (Siemens®) Ap: 4ch, 2ch, 3ch |
GLS and LVEF | - 11 ± 4 - |
65% | 48% | 180-day |
Shahul, 2015* 35 ICU patients with sepsis and septic shock |
TTE on admission and at 24 h post | cardiac perf. Analysis v1.1 (TomTec®) Ap: 4ch |
GLS and LVEF | - 6 (2.1–9) 21.7 ± 6.2 |
69% | 23.3% | 30-day |
Data on the number of patients on mechanical ventilation (MV) are reported, if available, at the time of echocardiographic assessment. Severity scores are provided according to the version reported by each study. Severity scores are reported according to the version of scoring adopted by the authors. Software used for global longitudinal strain (GLS) assessment are abbreviated for ease of reading
ED Emergency Department, ICU Intensive Care Unit, LVEF left ventricular ejection fraction, TTE trans-thoracic echocardiography, Ap apical view, 4ch four-chamber view, 2ch two-chamber view, 3ch three-chamber view, SAPS simplified acute physiology score, SOFA sequential organ failure assessment, APACHE acute physiology and chronic health evaluation
*In this study we obtained data from the 35 patients with septic shock, while the remaining 15 patients with sepsis were excluded
Quality assessment
Methodological design quality of the included observational studies was evaluated using the Newcastle-Ottawa scale (NOS) [20]. Briefly, the NOS appraises methodological quality in three domains: selection, comparability and outcome. Studies score points for each subset domain with a maximum of 9 points possible for assessing the quality of non-randomized studies in meta-analyses, and in particular they are classified as high-risk (1–3 points), intermediate-risk (4–5 points) or low-risk of bias (6–9 points).
Statistical analysis
Mean values and standard deviation of the variables of interest were collected for the outcome analysis. If data were reported only as median and interquartile range or confidence interval, we followed the Cochrane’s recommendation to approximate the values of mean and standard deviation (SD) [21].
Continuous outcome differences were analyzed using an inverse variance model with a 95% confidence interval. Values are reported as standard mean difference (SMD), P values were two-tailed and considered significant if < 0.05. The presence of statistical heterogeneity was assessed using the X2 (Cochran Q) test. Heterogeneity was likely if Q > df (degrees of freedom), suggested and confirmed if P ≤ 0.10. Quantification of heterogeneity was performed using the I2 statistic. Values of 0–24.9%, 25.0–49.9%, 50.0–74.9% and > 75.0% were considered as none, low, moderate and high heterogeneity respectively [22]. If heterogeneity was quantified as low or above, a more conservative random model was used. Publication bias was investigated by inspecting the funnel plot. Meta-analysis was performed using the review manager (Revman) for MAC (Version 5.3. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2014).
Results
Study selection
The literature search produced 49 titles on Medline and 33 on EMBASE. After eliminating duplicates, 64 titles were identified as potentially relevant. Abstracts were then appraised against inclusion criteria and full-text articles were retrieved for further analysis. Initially 39 articles were excluded because they were not relevant, and a further 18 studies were subsequently excluded for the following reasons: 4 focused on pediatric populations, 7 were animal studies, 4 were of a non-observational nature and 3 did not include a population with sepsis (see Additional file 1).
We identified 12 studies as suitable for the meta-analysis; however most of the studies did not directly included GLS data in relation to survival. We contacted the corresponding authors and all of them were able to provide data on GLS (see “Acknowledgements”). One study [23] was excluded because it was a subset of another study published later [24]. Of the remaining 11 studies, we included only 8 for our primary analysis [24–31]. The other three studies were included in the sensitivity analyses only: one study because it reported GLS data collected beyond the first 48 h of admission [32], and two for their design (retrospective [33] and case-control [34]). Figure 2 shows the PRISMA flowchart of the systematic search and qualitative synthesis.
As shown in Table 2, which presents the studies’ characteristics, the timing of transthoracic echocardiogram assessment varied from less than 24 h to within 48 h of ICU admission, while the proportion of patients undergoing mechanical ventilation ranged from 65% to 100% of the population. The views used by each study to calculate GLS varied from a single apical view to the average of three apical views. Software from four different technology companies were used in the selected studies (Table 2).
Primary outcome - GLS
Among the above studies, we collected GLS data on 794 patients, with an overall survival of 68% (n = 540). In the primary analysis including eight studies [24–31], survivors had more negative GLS values (better LV function) as compared with non-survivors (SMD − 0.26; 95% CI − 0.47, − 0.04; p = 0.02, Fig. 3) with low heterogeneity (I2 = 43%).
Secondary outcome - LVEF (in studies reporting GLS values)
The analysis of differences in LVEF between survivors and non-survivors included the same eight studies [24–31] and there were no differences in LVEF between groups (SMD 0.02; 95 % CI − 0.14, 0.17; p = 0.83, Fig. 4) with low heterogeneity (I2 = 3%).
Sensitivity analyses
The first sensitivity analysis was performed including the study from Zaky et al. [32] (echocardiography conducted within the first week after ICU admission, 53 patients with sepsis and/or septic shock, in-hospital mortality). The inclusion of this study did not affect the results of both GLS and LVEF analyses (p = 0.03 and p = 0.64, respectively). The inclusion of the case-control study of Ng et al. [34] (echocardiography conducted within 48 h after ICU admission, 33 ICU patients with septic shock, 90-day mortality) reduced the strength of the association between GLS and mortality (p = 0.07) but left unchanged the results on LVEF (p = 0.83). Similarly, the inclusion of the retrospective study of Dalla et al. [33] (echocardiography conducted within 48 h after ICU admission, 48 patients with sepsis and/or septic shock, 30-day mortality) blunted the strength of the association between GLS and mortality (p = 0.08) but left unchanged the results on LVEF (p = 0.89).
The sensitivity analysis with the leave-one-out-at-a-time approach did not largely affect the results on GLS: removal of one of the four studies resulted in values between p = 0.05 [24, 27] and p = 0.08 [25, 26]. Removal of the other four confirmed p < 0.05 [28–31]. No differences were seen in the analysis on LVEF using the leave-one-out-at-a-time approach. The planned sensitivity analysis excluding the studies at high risk of bias according to the NOS was not performed because all the included studies scored between 7 and 9 points, thus qualifying as low risk of bias. The inspection of funnel plots confirmed no risk of publication bias. Software from four different technology companies were used for GLS analysis in the included studies; thus the analysis grouping studies according to the software used was judged not feasible.
Discussion
To our knowledge, this is the first meta-analysis investigating the role of STE in identifying patients with sepsis and/or septic shock at higher risk of mortality. We found a significant association between worse (less negative) GLS values and mortality, while the most commonly adopted conventional parameter - LVEF - was not associated with mortality when analyzing the results of the studies included in the meta-analysis, confirming previous findings [12].
Our findings are not entirely surprising since the value of GLS has been recognized in various settings. Strain imaging can detect subclinical myocardial dysfunction in experimental studies on septic animals. In a rabbit model, Li et al. showed that 2 h after injecting endotoxin, GLS declined before changes in LVEF were manifest [35]. Similar results have been reported in anesthetized pigs receiving infusions of Escherichia coli, where STE detected myocardial dysfunction before significant changes in LVEF and cardiac output [36].
In the clinical setting, GLS is helpful in the diagnosis and/or prognosis of early stages of heart failure [37], chemotherapy-related cardiotoxicity [38], hypertrophic cardiomyopathy [39], pregnancy-related myocardial dysfunction [40], cardiac amyloidosis [41] and subclinical cardiomyopathies in patients with chronic kidney disease [42]. A meta-analysis showed superior prognostic value of GLS as compared to LVEF in the prediction of major adverse cardiac events in a heterogeneous population with underlying cardiac conditions [43]. For such reasons, STE use has been included in updated American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines [44]. All together with its prognostic value, GLS has been shown to have good reproducibility and non-significant intra-observer error, in many cases outperforming most conventional echocardiographic parameters, including LVEF, although small but significant inter-vendor differences still persist [45].
The aforementioned guidelines suggest normal values of peak GLS in the range of − 20% [44]. In our meta-analysis none of the reported mean GLS values fell in this range, reinforcing the fact that a degree of systolic impairment may be present in the majority of patients with sepsis and/or septic shock, both in survivors and non-survivors. Therefore, GLS could be considered a better surrogate of intrinsic LV myocardial function contrary to LVEF. One animal study showed 100% of myocardial depression as assessed via the pressure-volume loop (gold standard method) [46], but this finding differs from other studies [47, 48], leaving uncertainties in this field. Nonetheless, GLS may become a very useful parameter in the early evaluation of septic cardiomyopathy. For instance, Boissier et al. elegantly showed impaired values of GLS in the first 24 h in patients developing secondary LV hypo-kinesia (defined as reduced LVEF on day 2 or day 3 after a normal value of LVEF on the first day in the ICU), confirming higher sensitivity of GLS in detecting sub-clinical cardiomyopathy. Moreover, in this study even patients with normal LVEF had mean GLS values worse than − 20%, highlighting the ability of GLS in detecting myocardial impairment not shown by LVEF. Moreover, only a few patients had good GLS values and all of them had normal LVEF [31].
Importantly, GLS values are different in other populations of critically ill patients, as shown by Dalla et al. [33] who reported a prevalence of depressed longitudinal LV function as high as 50% in patients with septic shock, while the prevalence was below 9% in controls (trauma patients without septic shock) [33]. Similarly, Ng et al. [34] observed worse GLS values in patients with septic shock as compared with those with sepsis only (− 14.5% vs − 18.3%, respectively) and significantly improved strain after recovery from septic shock in patients weaned off vasopressors within 72 h. However, Ng et al. [34] also demonstrated some improvement (not statistically significant) in GLS in a smaller group of patients remaining vasopressor-dependent [49]. On the contrary, another study in patients with septic shock found unchanged GLS over time despite normalization in LVEF and cardiac biomarkers and clinical recovery [27].
The use of STE may possibly overcome some limitations of LVEF, in relation to variability of loading conditions and geometric assumptions, indeed, as LVEF is a direct measure of the change in blood pool volume and thus dependent on volume and pressure load on the myocardium [50, 51], with systolic function increasing during vasodilatation and decreasing in states of vasoconstriction [51, 52]. It has been claimed that GLS is a reliable, reproducible, and sensitive modality for assessing cardiac systolic function [43, 53, 54]; however, it should be kept in mind that GLS is also dependent on LV loading conditions, especially afterload changes, with longitudinal fibers suffering from higher wall stress due to their orientation. This assumption is confirmed by animal [55] and clinical studies [56–59]. A recent study by Nafati et al. demonstrated that in a heterogeneous population of preload-dependent critically ill patients, GLS is significantly affected (more negative values indicating improved LV function) after fluid resuscitation [60]. In critically ill patients with sepsis and/or septic shock it is possible that after the initial fluid resuscitation, afterload changes play a more important role than preload, particularly in terms of outcome. For instance, in patients with aortic stenosis with varying afterload, GLS was shown to be sensitive to these changes, while LVEF was not [61, 62]. It may be that this is also reflected in the value of GLS to predict mortality. Certainly, more research is warranted to understand the variation in GLS according to preload and afterload under stable hemodynamic and respiratory support in critically ill patients. Of course, LVEF variations are also related to changes in afterload more than in intrinsic myocardial contractility [14], and in this regard Vieillard-Baron et al. repeatedly confirmed the variability in the incidence of systolic dysfunction as evaluated by LVEF at different time points after the onset of septic shock [11, 51]. An independent association between hyperdynamic conditions (LVEF > 70%) and mortality was identified in a large retrospective cohort study of critically ill patients [63]. A further limitation in the estimation of systolic function by means of LVEF is the geometric assumptions. Wall motion measurements evaluating displacement cannot differentiate between active or passive movement of a myocardial segment with inward systolic movements dragging diseased segments, and thus the resulting LVEF is relatively unaffected by subtle systolic changes [64]. On the contrary, deformation analyses (i.e. GLS) allow discrimination between active and passive myocardial tissue movement and are less affected by measurement errors because they avoid geometric assumptions [65]. It is possible that a reduction in longitudinal strain is compensated by other factors and LVEF remains normal for such mechanisms. A recent study confirmed the hypothesis that strain better reflects systolic function as compared with LVEF, especially in patients with preserved LVEF, where the authors showed a flatter slope for GLS/LVEF correlation (slope − 0.6) as compared with patients with decreased LVEF (slope − 1.6). Such findings indicate that LVEF may be unaffected if a reduction in GLS is compensated by a change in other parameters (increase in circumferential strain and/or increase in LV wall thickness and/or reduction in LV end-diastolic volume), and that GLS can decrease earlier before effects on LVEF are manifest [66].
The use of GLS probably offers advantages over assessment of the systolic pulsed wave (s’) obtained with tissue Doppler imaging (TDI). The s’ TDI of the base of LV wall is another index of longitudinal LV systolic function and has been validated against LVEF in patients with cardiac disease [67]. In critically ill patients, TDI has been predominantly used in the assessment of LV diastolic function [9], but there is growing literature on s’ TDI [25, 26]. However, s’ provides an angle-dependent, unidirectional (longitudinal) and unidimensional (one LV segment) assessment of myocardial motion, thus being exposed to underestimation or overestimation (regional wall motion abnormalities, tethering, etc.). In this context, GLS has advantages over TDI, likewise assessing all the LV segments and being less angle-dependent [68, 69], but on the other hand better imaging definition is required compared with TDI [70]. Possible M-mode surrogates of GLS may be longitudinal wall fractional shortening, the curved anatomical M-mode fractional shortening and the mitral annulus systolic plane excursion. Such parameters have recently been shown to correlate strongly with GLS, with longitudinal wall fractional shortening being the best unbiased strain predictor. Given the simplicity of M-mode measurements, this may have significant clinical and practical implications for future critical care echocardiography investigations [71].
From a clinical perspective, obtaining a more accurate identification of underlying septic cardiomyopathy has not only prognostic but also therapeutic value. For instance, tachycardia is one of the hallmarks of sepsis and it is associated with worse clinical outcomes in critically ill patients [72]. However, it is still difficult to distinguish between tachycardia as an adaptive response to low preload conditions and tachycardia related to a persistent hyperadrenergic state (in turn responsible for septic cardiomyopathy). Lanspa et al. identified an association between impaired GLS and tachycardia [28]. Despite this, controversy remains surrounding the use of beta blocker therapy for treatment of tachycardic patients with sepsis and/or septic shock [73, 74], and it is advisable that future studies on beta blockade in sepsis evaluate LVSD by STE for the identification of patients who might benefit from pharmacological heart rate control.
Furthermore, with the wider use of echocardiography we believe that RV function measured with STE should be a focus of future research. The RV has a preponderance of longitudinal fibers and can be assessed with longitudinal strain [75] and there is growing evidence with regard to the prognostic value of RV strain, for instance in patients with pulmonary hypertension [76]. The utility of RV strain in sepsis has not been assessed in our meta-analysis because of the small number of available studies, but interesting findings have been reported by Orde et al., where higher RV strain was identified in sepsis survivors despite similar values of LV strain [29]. However, RV function - more than LV - is affected not only by preload but also by mechanical ventilation, making its assessment challenging in mechanically ventilated patients with septic shock.
Limitations
Our meta-analysis has the main limitation of exploring an association between values of GLS and mortality in patients with severe sepsis and/or septic shock and GLS values that were directly reported or collected by contacting corresponding authors, but that are not adjusted for confounders by regression/multivariate analyses. It would have been valuable to adjust these values for patient’s severity score, presence and mode of mechanical ventilation, dose of vasoconstrictors and hemodynamic conditions and fluid balance, etc. Unfortunately, this is not feasible without accurate access to individual patient data from all studies, and it remains the main limitation of the present meta-analysis. Moreover, with regards to the GLS, half of the sensitivity analyses moved the p value between 0.05 and 0.08, while no changes were noted on LVEF which continued not to be associated with sepsis outcome.
We found only two papers also reporting values of circumferential and/or radial strain [26, 30], therefore these values were not considered for analysis. Nonetheless, sub-endocardial myocardial fibers are oriented longitudinally and these fibers are especially sensitive to ischemia and increased wall stress [77], thus GLS could be reliably considered as a marker of myocardial dysfunction in sepsis.
There are some clinical limitations in the introduction of GLS in clinical practice. An initial one was posed by inter-vendor differences in software algorithms, which makes normal values difficult to standardize due to biases among vendors. Software uses information gathered from different myocardial layers, endocardial (E-GLS) and mid-wall (M-GLS) for the calculation of GLS. Literature suggests that there is no difference in terms of robustness between E-GLS and M-GLS across vendors [78] and a recent study showed good reproducibility of GLS measurements, which in many cases was superior to other conventional echocardiographic measurements [45]. We were unable to analyze subgroups of studies according to the software used for GLS assessment as software from four different technology companies was used for GLS quantification in the eight studies included. With technological advances, expert calls for concordance on vendor strain software analysis, and with more widespread use of GLS, we anticipate that STE may become a routine measurement in the future. In the past, GLS analysis was mainly performed as an off-line calculation using remote workstations rather than being a bedside application. Currently, after appropriate training, doctors may assess GLS in about 10 min per patient, and new advanced echocardiographic machines have embedded software packages for real-time GLS measurement, making such approaches applicable at the bedside. Strain assessed with STE measures both regional and global functions, assessing the function of sub-endocardial longitudinal fibers of all 17 myocardial segments, and has been validated as the most consistently reproducible measurement [79]. Although global strain values may not entirely reflect segmental changes, septic cardiomyopathy is more of a general process mediated by a hyper-adrenergic state [80] combined with tissue inflammation [81], sarcolemmal permeability [82], free radicals [83] and mitochondrial dysfunction [84]; therefore, the limitation of global assessment is likely to be clinically irrelevant in this group of patients.
However, the frame rate of STE is limited to the relatively low frame rate of the B-mode. When the frame rate is too low, the tracking quality is reduced due to frame-to-frame decorrelation. This can often be a problem if the heart rate is high, which happens in most patients with sepsis. Strain measurement does not only require training and time at the bedside, but needs high-quality images. Studies in the non-critically ill report 7–9% suboptimal image quality for STE analysis [85, 86], and one study in patients with sepsis reported slightly higher incidence (13%) [29]; however, a more recent study on STE reported the feasibility of at least one GLS measurement during the first 3 days in the ICU in up to 59% of the population (n = 78/132) [31]. It should be noted that the feasibility of GLS assessment may depend on the methodology of acquisition and on patient-related factors. In the first case, feasibility may become lower if the clinicians decide to acquire GLS averaging three apical views (in our meta-analysis this was done only in three out of eight studies). From the patient’s perspective, chronic obstructive pulmonary disease could be one of the main factors associated with inability to obtain echocardiographic images suitable for quantitative assessments, as shown by one study for both LVEF and GLS [23]. Although echocardiography imaging in the critically ill can be difficult, ICU physicians keen to implement echocardiography should keep in mind that STE still remains feasible in a large number of patients!
Conclusions
Worse values of global longitudinal strain are associated with higher mortality in patients with severe sepsis or septic shock, while such an association is not valid for left ventricular ejection fraction. More research is warranted to elucidate such an association, which could be related to the ability of speckle-tracking echocardiography in demonstrating underlying intrinsic myocardial disease as opposed to left ventricular ejection fraction.
Additional file
Acknowledgements
We would like to acknowledge the contribution of corresponding authors from five studies. They responded to our request providing GLS and LVEF data about their studies. Michael J Lanspa [28], Pauline Ng [34], Francesca Innocenti [24], Armand Mekontso-Dessap [31], Sajid Shahul and Ariel Mueller [30], Keti Dalla and Sven-Erik Ricksten [33].
Funding
Not applicable.
Availability of data and materials
The authors declare they keep the files containing data safely stored; these will be available to the editor on request.
Abbreviations
- GLS
Global longitudinal strain
- LV
Left ventricular
- LVEF
Left ventricular ejection fraction
- LVSD
Left ventricular systolic dysfunction
- NOS
Newcastle-Ottawa scale
- PICOS
Patient, population or problem, intervention, comparison, outcomes and study design (or setting)
- PRISMA
Preferred reporting items for systematic reviews and meta-analyses
- SOFA
Sequential organ failure assessment
- STE
Speckle-tracking echocardiography
- TDI
Tissue Doppler imaging
Authors’ contributions
All the authors read and discussed the critical issues of the manuscript and agreed on the rationale of this meta-analysis. Three investigators (FS, CC and AA) independently screened titles and abstracts produced by the search and identified potentially relevant articles. Full-text articles that were identified as relevant were then assessed against the eligibility criteria. Discrepancies were resolved by consensus and/or by involving other authors (MC, AVB and NF). Three authors (AA, LT and FLL) downloaded studies. Two reviewers (FS and CC) independently extracted data from individual studies, contacted corresponding authors and entered information into a pre-designed data collection form, which all the other authors double-checked for errors (MC, AVB, NF, AA, LT and FLL). All the authors edited the manuscript with significant changes and suggestions. All the authors have read and approved the final version of the manuscript.
Not applicable.
Not applicable.
The authors declare that they have no competing interests.
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
F. Sanfilippo, Phone: 00393289178766, Email: filipposanfi@yahoo.it
C. Corredor, Email: carloscorredor@doctors.org.uk
N. Fletcher, Email: snick@doctors.org.uk
L. Tritapepe, Email: luigi.tritapepe@uniroma1.it
F. L. Lorini, Email: llorini@asst-pg23.it
A. Arcadipane, Email: aarcadipane@ismett.edu
A. Vieillard-Baron, Email: antoine.vieillard-baron@aphp.fr
M. Cecconi, Email: m.cecconi@nhs.net
References
- 1.Singer M, Deutschman CS, Seymour CW, Shankar-Hari M, Annane D, Bauer M, Bellomo R, Bernard GR, Chiche JD, Coopersmith CM, et al. The third international consensus definitions for sepsis and septic shock (Sepsis-3) JAMA. 2016;315(8):801–810. doi: 10.1001/jama.2016.0287. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Antonelli M, Bonten M, Chastre J, Citerio G, Conti G, Curtis JR, De Backer D, Hedenstierna G, Joannidis M, Macrae D, et al. Year in review in intensive care medicine 2011. II. Cardiovascular, infections, pneumonia and sepsis, critical care organization and outcome, education, ultrasonography, metabolism and coagulation. Intensive Care Med. 2012;38(3):345–358. doi: 10.1007/s00134-012-2467-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Gullo A, Foti A, Murabito P, Li Volti G, Astuto M, Stissi C, Rubulotta F, Sanfilippo F, Santonocito C, Sganga G, et al. Spectrum of sepsis, mediators, source control and management of bundles. Front Biosci (Elite Ed) 2010;2:906–911. doi: 10.2741/e150. [DOI] [PubMed] [Google Scholar]
- 4.Beesley SJ, Weber G, Sarge T, Nikravan S, Grissom CK, Lanspa MJ, Shahul S, Brown SM. Septic cardiomyopathy. Crit Care Med. 2018;46(4):625–634. doi: 10.1097/CCM.0000000000002851. [DOI] [PubMed] [Google Scholar]
- 5.Hunter JD, Doddi M. Sepsis and the heart. Br J Anaesth. 2010;104(1):3–11. doi: 10.1093/bja/aep339. [DOI] [PubMed] [Google Scholar]
- 6.Torgersen C, Moser P, Luckner G, Mayr V, Jochberger S, Hasibeder WR, Dunser MW. Macroscopic postmortem findings in 235 surgical intensive care patients with sepsis. Anesth Analg. 2009;108(6):1841–1847. doi: 10.1213/ane.0b013e318195e11d. [DOI] [PubMed] [Google Scholar]
- 7.Ammann P, Fehr T, Minder EI, Gunter C, Bertel O. Elevation of troponin I in sepsis and septic shock. Intensive Care Med. 2001;27(6):965–969. doi: 10.1007/s001340100920. [DOI] [PubMed] [Google Scholar]
- 8.Sanfilippo F, Corredor C, Fletcher N, Landesberg G, Benedetto U, Foex P, Cecconi M. Diastolic dysfunction and mortality in septic patients: a systematic review and meta-analysis. Intensive Care Med. 2015;41(6):1004–13. 10.1007/s00134-015-3748-7. Epub 2015 Mar 24. [DOI] [PubMed]
- 9.Sanfilippo F, Corredor C, Arcadipane A, Landesberg G, Vieillard-Baron A, Cecconi M, Fletcher N. Tissue Doppler assessment of diastolic function and relationship with mortality in critically ill septic patients: a systematic review and meta-analysis. Br J Anaesth. 2017;119(4):583–594. doi: 10.1093/bja/aex254. [DOI] [PubMed] [Google Scholar]
- 10.Parker MM, Shelhamer JH, Bacharach SL, Green MV, Natanson C, Frederick TM, Damske BA, Parrillo JE. Profound but reversible myocardial depression in patients with septic shock. Ann Intern Med. 1984;100(4):483–490. doi: 10.7326/0003-4819-100-4-483. [DOI] [PubMed] [Google Scholar]
- 11.Vieillard-Baron A, Caille V, Charron C, Belliard G, Page B, Jardin F. Actual incidence of global left ventricular hypokinesia in adult septic shock. Crit Care Med. 2008;36(6):1701–1706. doi: 10.1097/CCM.0b013e318174db05. [DOI] [PubMed] [Google Scholar]
- 12.Huang SJ, Nalos M, McLean AS. Is early ventricular dysfunction or dilatation associated with lower mortality rate in adult severe sepsis and septic shock? A meta-analysis. Crit Care. 2013;17(3):R96. doi: 10.1186/cc12741. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Cecconi M, De Backer D, Antonelli M, Beale R, Bakker J, Hofer C, Jaeschke R, Mebazaa A, Pinsky MR, Teboul JL, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40(12):1795–1815. doi: 10.1007/s00134-014-3525-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Vieillard-Baron A. Septic cardiomyopathy. Ann Intensive Care. 2011;1(1):6. doi: 10.1186/2110-5820-1-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Vignon P, Huang SJ. Global longitudinal strain in septic cardiomyopathy: the hidden part of the iceberg? Intensive Care Med. 2015;41(10):1851–1853. doi: 10.1007/s00134-015-3962-3. [DOI] [PubMed] [Google Scholar]
- 16.Leitman M, Lysyansky P, Sidenko S, Shir V, Peleg E, Binenbaum M, Kaluski E, Krakover R, Vered Z. Two-dimensional strain-a novel software for real-time quantitative echocardiographic assessment of myocardial function. J Am Soc Echocardiogr. 2004;17(10):1021–1029. doi: 10.1016/j.echo.2004.06.019. [DOI] [PubMed] [Google Scholar]
- 17.Mor-Avi V, Lang RM, Badano LP, Belohlavek M, Cardim NM, Derumeaux G, Galderisi M, Marwick T, Nagueh SF, Sengupta PP, et al. Current and evolving echocardiographic techniques for the quantitative evaluation of cardiac mechanics: ASE/EAE consensus statement on methodology and indications endorsed by the Japanese Society of Echocardiography. Eur J Echocardiogr. 2011;12(3):167–205. doi: 10.1093/ejechocard/jer021. [DOI] [PubMed] [Google Scholar]
- 18.Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, Clarke M, Devereaux PJ, Kleijnen J, Moher D. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 2009;62(10):e1–34. doi: 10.1016/j.jclinepi.2009.06.006. [DOI] [PubMed] [Google Scholar]
- 19.Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, Sevransky JE, Sprung CL, Douglas IS, Jaeschke R, et al. Surviving Sepsis campaign: international guidelines for management of severe sepsis and septic shock, 2012. Intensive Care Med. 2013;39(2):165–228. doi: 10.1007/s00134-012-2769-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Wells G, Shea B, O'Connell D, Peterson J, Welch V, Losos M, Tugwell P. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomized studies in meta-analyses. http://www.ohri.ca/programs/clinical_epidemiology/oxford.htm. Accessed 10 Jan 2018.
- 21.Hozo SP, Djulbegovic B, Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol. 2005;5:13. doi: 10.1186/1471-2288-5-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557–560. doi: 10.1136/bmj.327.7414.557. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Palmieri V, Innocenti F, Guzzo A, Guerrini E, Vignaroli D, Pini R. Left ventricular systolic longitudinal function as predictor of outcome in patients with sepsis. Circ Cardiovasc Imaging. 2015;8(11):e003865. doi: 10.1161/CIRCIMAGING.115.003865. [DOI] [PubMed] [Google Scholar]
- 24.Innocenti F, Palmieri V, Guzzo A, Stefanone VT, Donnini C, Pini R. SOFA score and left ventricular systolic function as predictors of short-term outcome in patients with sepsis. Intern Emerg Med. 2018;13(1):51–58. 10.1007/s11739-016-1579-3. Epub 2016 Dec 1. [DOI] [PubMed]
- 25.Chang WT, Lee WH, Lee WT, Chen PS, Su YR, Liu PY, Liu YW, Tsai WC. Left ventricular global longitudinal strain is independently associated with mortality in septic shock patients. Intensive Care Med. 2015;41(10):1791–1799. doi: 10.1007/s00134-015-3970-3. [DOI] [PubMed] [Google Scholar]
- 26.Landesberg G, Jaffe AS, Gilon D, Levin PD, Goodman S, Abu-Baih A, Beeri R, Weissman C, Sprung CL, Landesberg A. Troponin elevation in severe sepsis and septic shock: the role of left ventricular diastolic dysfunction and right ventricular dilatation*. Crit Care Med. 2014;42(4):790–800. doi: 10.1097/CCM.0000000000000107. [DOI] [PubMed] [Google Scholar]
- 27.De Geer L, Engvall J, Oscarsson A. Strain echocardiography in septic shock - a comparison with systolic and diastolic function parameters, cardiac biomarkers and outcome. Crit Care. 2015;19:122. doi: 10.1186/s13054-015-0857-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Lanspa MJ, Shahul S, Hersh A, Wilson EL, Olsen TD, Hirshberg EL, Grissom CK, Brown SM. Associations among left ventricular systolic function, tachycardia, and cardiac preload in septic patients. Ann Intensive Care. 2017;7(1):17. doi: 10.1186/s13613-017-0240-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Orde SR, Pulido JN, Masaki M, Gillespie S, Spoon JN, Kane GC, Oh JK. Outcome prediction in sepsis: speckle tracking echocardiography based assessment of myocardial function. Crit Care. 2014;18(4):R149. doi: 10.1186/cc13987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Shahul S, Gulati G, Hacker MR, Mahmood F, Canelli R, Nizamuddin J, Mahmood B, Mueller A, Simon BA, Novack V, et al. Detection of myocardial dysfunction in septic shock: a speckle-tracking echocardiography study. Anesth Analg. 2015;121(6):1547–1554. doi: 10.1213/ANE.0000000000000943. [DOI] [PubMed] [Google Scholar]
- 31.Boissier F, Razazi K, Seemann A, Bedet A, Thille AW, de Prost N, Lim P, Brun-Buisson C, Mekontso Dessap A. Left ventricular systolic dysfunction during septic shock: the role of loading conditions. Intensive Care Med. 2017;43(5):633–642. doi: 10.1007/s00134-017-4698-z. [DOI] [PubMed] [Google Scholar]
- 32.Zaky A, Gill EA, Lin CP, Bendjelid K, Treggiari MM. Characteristics of sepsis-induced cardiac dysfunction using speckle-tracking echocardiography: a feasibility study. Anaesth Intensive Care. 2016;44(1):65–76. doi: 10.1177/0310057X1604400111. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Dalla K, Hallman C, Bech-Hanssen O, Haney M, Ricksten SE. Strain echocardiography identifies impaired longitudinal systolic function in patients with septic shock and preserved ejection fraction. Cardiovasc Ultrasound. 2015;13:30. doi: 10.1186/s12947-015-0025-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Ng PY, Sin WC, Ng AK, Chan WM. Speckle tracking echocardiography in patients with septic shock: a case control study (SPECKSS) Crit Care. 2016;20(1):145. doi: 10.1186/s13054-016-1327-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Li T, Liu JJ, Du WH, Wang X, Chen ZQ, Zhang LC. 2D speckle tracking imaging to assess sepsis induced early systolic myocardial dysfunction and its underlying mechanisms. Eur Rev Med Pharmacol Sci. 2014;18(20):3105–3114. [PubMed] [Google Scholar]
- 36.Hestenes SM, Halvorsen PS, Skulstad H, Remme EW, Espinoza A, Hyler S, Bugge JF, Fosse E, Nielsen EW, Edvardsen T. Advantages of strain echocardiography in assessment of myocardial function in severe sepsis: an experimental study. Crit Care Med. 2014;42(6):e432–e440. doi: 10.1097/CCM.0000000000000310. [DOI] [PubMed] [Google Scholar]
- 37.Mignot A, Donal E, Zaroui A, Reant P, Salem A, Hamon C, Monzy S, Roudaut R, Habib G, Lafitte S. Global longitudinal strain as a major predictor of cardiac events in patients with depressed left ventricular function: a multicenter study. J Am Soc Echocardiogr. 2010;23(10):1019–1024. doi: 10.1016/j.echo.2010.07.019. [DOI] [PubMed] [Google Scholar]
- 38.Ho E, Brown A, Barrett P, Morgan RB, King G, Kennedy MJ, Murphy RT. Subclinical anthracycline- and trastuzumab-induced cardiotoxicity in the long-term follow-up of asymptomatic breast cancer survivors: a speckle tracking echocardiographic study. Heart. 2010;96(9):701–707. doi: 10.1136/hrt.2009.173997. [DOI] [PubMed] [Google Scholar]
- 39.Yajima R, Kataoka A, Takahashi A, Uehara M, Saito M, Yamaguchi C, Lee K, Komuro I, Funabashi N. Distinguishing focal fibrotic lesions and non-fibrotic lesions in hypertrophic cardiomyopathy by assessment of regional myocardial strain using two-dimensional speckle tracking echocardiography: comparison with multislice CT. Int J Cardiol. 2012;158(3):423–432. doi: 10.1016/j.ijcard.2011.01.096. [DOI] [PubMed] [Google Scholar]
- 40.Shahul S, Rhee J, Hacker MR, Gulati G, Mitchell JD, Hess P, Mahmood F, Arany Z, Rana S, Talmor D. Subclinical left ventricular dysfunction in preeclamptic women with preserved left ventricular ejection fraction: a 2D speckle-tracking imaging study. Circ Cardiovasc Imaging. 2012;5(6):734–739. doi: 10.1161/CIRCIMAGING.112.973818. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Bellavia D, Abraham TP, Pellikka PA, Al-Zahrani GB, Dispenzieri A, Oh JK, Bailey KR, Wood CM, Novo S, Miyazaki C, et al. Detection of left ventricular systolic dysfunction in cardiac amyloidosis with strain rate echocardiography. J Am Soc Echocardiogr. 2007;20(10):1194–1202. doi: 10.1016/j.echo.2007.02.025. [DOI] [PubMed] [Google Scholar]
- 42.Liu YW, Su CT, Sung JM, Wang SP, Su YR, Yang CS, Tsai LM, Chen JH, Tsai WC. Association of left ventricular longitudinal strain with mortality among stable hemodialysis patients with preserved left ventricular ejection fraction. Clin J Am Soc Nephrol. 2013;8(9):1564–1574. doi: 10.2215/CJN.10671012. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Kalam K, Otahal P, Marwick TH. Prognostic implications of global LV dysfunction: a systematic review and meta-analysis of global longitudinal strain and ejection fraction. Heart. 2014;100(21):1673–1680. doi: 10.1136/heartjnl-2014-305538. [DOI] [PubMed] [Google Scholar]
- 44.Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, Flachskampf FA, Foster E, Goldstein SA, Kuznetsova T, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2015;28(1):1–39.e14. doi: 10.1016/j.echo.2014.10.003. [DOI] [PubMed] [Google Scholar]
- 45.Farsalinos KE, Daraban AM, Unlu S, Thomas JD, Badano LP, Voigt JU. Head-to-head comparison of global longitudinal strain measurements among nine different vendors: the EACVI/ASE inter-vendor comparison study. J Am Soc Echocardiogr. 2015;28(10):1171–1181. doi: 10.1016/j.echo.2015.06.011. [DOI] [PubMed] [Google Scholar]
- 46.Barraud D, Faivre V, Damy T, Welschbillig S, Gayat E, Heymes C, Payen D, Shah AM, Mebazaa A. Levosimendan restores both systolic and diastolic cardiac performance in lipopolysaccharide-treated rabbits: comparison with dobutamine and milrinone. Crit Care Med. 2007;35(5):1376–1382. doi: 10.1097/01.CCM.0000261889.18102.84. [DOI] [PubMed] [Google Scholar]
- 47.Jianhui L, Rosenblatt-Velin N, Loukili N, Pacher P, Feihl F, Waeber B, Liaudet L. Endotoxin impairs cardiac hemodynamics by affecting loading conditions but not by reducing cardiac inotropism. Am J Phys Heart Circ Phys. 2010;299(2):H492–H501. doi: 10.1152/ajpheart.01135.2009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Pinsky MR, Rico P. Cardiac contractility is not depressed in early canine endotoxic shock. Am J Respir Crit Care Med. 2000;161(4 Pt 1):1087–1093. doi: 10.1164/ajrccm.161.4.9904033. [DOI] [PubMed] [Google Scholar]
- 49.Sanfilippo F, Santonocito C, Panarello G, Arcadipane A. The role of speckle tracking echocardiography for prognostication in patients with severe sepsis or septic shock. Crit Care. 2016;20:284. doi: 10.1186/s13054-016-1451-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Szymanski C, Levy F, Tribouilloy C. Should LVEF be replaced by global longitudinal strain? Heart. 2014;100(21):1655–1656. doi: 10.1136/heartjnl-2014-306186. [DOI] [PubMed] [Google Scholar]
- 51.Vieillard Baron A, Schmitt JM, Beauchet A, Augarde R, Prin S, Page B, Jardin F. Early preload adaptation in septic shock? A transesophageal echocardiographic study. Anesthesiology. 2001;94(3):400–406. doi: 10.1097/00000542-200103000-00007. [DOI] [PubMed] [Google Scholar]
- 52.Jardin F, Fourme T, Page B, Loubieres Y, Vieillard-Baron A, Beauchet A, Bourdarias JP. Persistent preload defect in severe sepsis despite fluid loading: a longitudinal echocardiographic study in patients with septic shock. Chest. 1999;116(5):1354–1359. doi: 10.1378/chest.116.5.1354. [DOI] [PubMed] [Google Scholar]
- 53.Basu S, Frank LH, Fenton KE, Sable CA, Levy RJ, Berger JT. Two-dimensional speckle tracking imaging detects impaired myocardial performance in children with septic shock, not recognized by conventional echocardiography. Pediatr Crit Care Med. 2012;13(3):259–264. doi: 10.1097/PCC.0b013e3182288445. [DOI] [PubMed] [Google Scholar]
- 54.Liu YW, Tsai WC, Su CT, Lin CC, Chen JH. Evidence of left ventricular systolic dysfunction detected by automated function imaging in patients with heart failure and preserved left ventricular ejection fraction. J Card Fail. 2009;15(9):782–789. doi: 10.1016/j.cardfail.2009.05.006. [DOI] [PubMed] [Google Scholar]
- 55.Rosner A, Bijnens B, Hansen M, How OJ, Aarsaether E, Muller S, Sutherland GR, Myrmel T. Left ventricular size determines tissue Doppler-derived longitudinal strain and strain rate. Eur J Echocardiogr. 2009;10(2):271–277. doi: 10.1093/ejechocard/jen230. [DOI] [PubMed] [Google Scholar]
- 56.Burns AT, La Gerche A, D'Hooge J, MacIsaac AI, Prior DL. Left ventricular strain and strain rate: characterization of the effect of load in human subjects. Eur J Echocardiogr. 2010;11(3):283–289. doi: 10.1093/ejechocard/jep214. [DOI] [PubMed] [Google Scholar]
- 57.Aissaoui N, Guerot E, Combes A, Delouche A, Chastre J, Leprince P, Leger P, Diehl JL, Fagon JY, Diebold B. Two-dimensional strain rate and Doppler tissue myocardial velocities: analysis by echocardiography of hemodynamic and functional changes of the failed left ventricle during different degrees of extracorporeal life support. J Am Soc Echocardiogr. 2012;25(6):632–640. doi: 10.1016/j.echo.2012.02.009. [DOI] [PubMed] [Google Scholar]
- 58.Choi JO, Shin DH, Cho SW, Song YB, Kim JH, Kim YG, Lee SC, Park SW. Effect of preload on left ventricular longitudinal strain by 2D speckle tracking. Echocardiography (Mount Kisco, NY) 2008;25(8):873–879. doi: 10.1111/j.1540-8175.2008.00707.x. [DOI] [PubMed] [Google Scholar]
- 59.Park HE, Chang SA, Kim HK, Shin DH, Kim JH, Seo MK, Kim YJ, Cho GY, Sohn DW, Oh BH, et al. Impact of loading condition on the 2D speckle tracking-derived left ventricular dyssynchrony index in nonischemic dilated cardiomyopathy. Circ Cardiovasc Imaging. 2010;3(3):272–281. doi: 10.1161/CIRCIMAGING.109.890848. [DOI] [PubMed] [Google Scholar]
- 60.Nafati C, Gardette M, Leone M, Reydellet L, Blasco V, Lannelongue A, Sayagh F, Wiramus S, Antonini F, Albanese J, et al. Use of speckle-tracking strain in preload-dependent patients, need for cautious interpretation! Ann Intensive Care. 2018;8(1):29. doi: 10.1186/s13613-018-0376-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Carasso S, Cohen O, Mutlak D, Adler Z, Lessick J, Reisner SA, Rakowski H, Bolotin G, Agmon Y. Differential effects of afterload on left ventricular long- and short-axis function: insights from a clinical model of patients with aortic valve stenosis undergoing aortic valve replacement. Am Heart J. 2009;158(4):540–545. doi: 10.1016/j.ahj.2009.07.008. [DOI] [PubMed] [Google Scholar]
- 62.Miyazaki S, Daimon M, Miyazaki T, Onishi Y, Koiso Y, Nishizaki Y, Ichikawa R, Chiang SJ, Makinae H, Suzuki H, et al. Global longitudinal strain in relation to the severity of aortic stenosis: a two-dimensional speckle-tracking study. Echocardiography (Mount Kisco, NY) 2011;28(7):703–708. doi: 10.1111/j.1540-8175.2011.01419.x. [DOI] [PubMed] [Google Scholar]
- 63.Paonessa JR, Brennan T, Pimentel M, Steinhaus D, Feng M, Celi LA. Hyperdynamic left ventricular ejection fraction in the intensive care unit. Crit Care. 2015;19:288. doi: 10.1186/s13054-015-1012-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Negishi K, Negishi T, Haluska BA, Hare JL, Plana JC, Marwick TH. Use of speckle strain to assess left ventricular responses to cardiotoxic chemotherapy and cardioprotection. Eur Heart J Cardiovasc Imaging. 2014;15(3):324–331. doi: 10.1093/ehjci/jet159. [DOI] [PubMed] [Google Scholar]
- 65.Nesbitt GC, Mankad S, Oh JK. Strain imaging in echocardiography: methods and clinical applications. Int J Cardiovasc Imaging. 2009;25(Suppl 1):9–22. doi: 10.1007/s10554-008-9414-1. [DOI] [PubMed] [Google Scholar]
- 66.Stokke TM, Hasselberg NE, Smedsrud MK, Sarvari SI, Haugaa KH, Smiseth OA, Edvardsen T, Remme EW. Geometry as a confounder when assessing ventricular systolic function: comparison between ejection fraction and strain. J Am Coll Cardiol. 2017;70(8):942–954. doi: 10.1016/j.jacc.2017.06.046. [DOI] [PubMed] [Google Scholar]
- 67.van Melle JP, van der Vleuten PA, Hummel YM, Nijveldt R, Tio RA, Voors AA, Zijlstra F. Predictive value of tissue Doppler imaging for left ventricular ejection fraction, remodelling, and infarct size after percutaneous coronary intervention for acute myocardial infarction. Eur J Echocardiogr. 2010;11(7):596–601. doi: 10.1093/ejechocard/jeq023. [DOI] [PubMed] [Google Scholar]
- 68.Geyer H, Caracciolo G, Abe H, Wilansky S, Carerj S, Gentile F, Nesser HJ, Khandheria B, Narula J, Sengupta PP. Assessment of myocardial mechanics using speckle tracking echocardiography: fundamentals and clinical applications. J Am Soc Echocardiogr. 2010;23(4):351–369. doi: 10.1016/j.echo.2010.02.015. [DOI] [PubMed] [Google Scholar]
- 69.Amundsen BH, Helle-Valle T, Edvardsen T, Torp H, Crosby J, Lyseggen E, Stoylen A, Ihlen H, Lima JA, Smiseth OA, et al. Noninvasive myocardial strain measurement by speckle tracking echocardiography: validation against sonomicrometry and tagged magnetic resonance imaging. J Am Coll Cardiol. 2006;47(4):789–793. doi: 10.1016/j.jacc.2005.10.040. [DOI] [PubMed] [Google Scholar]
- 70.Buss SJ, Mereles D, Emami M, Korosoglou G, Riffel JH, Bertel D, Schonland SO, Hegenbart U, Katus HA, Hardt SE. Rapid assessment of longitudinal systolic left ventricular function using speckle tracking of the mitral annulus. Clin Res Cardiol. 2012;101(4):273–280. doi: 10.1007/s00392-011-0389-x. [DOI] [PubMed] [Google Scholar]
- 71.Huang SJ, Ting I, Huang AM, Slama M, McLean AS. Longitudinal wall fractional shortening: an M-mode index based on mitral annular plane systolic excursion (MAPSE) that correlates and predicts left ventricular longitudinal strain (LVLS) in intensive care patients. Crit Care. 2017;21(1):292. doi: 10.1186/s13054-017-1876-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 72.Sander O, Welters ID, Foex P, Sear JW. Impact of prolonged elevated heart rate on incidence of major cardiac events in critically ill patients with a high risk of cardiac complications. Crit Care Med. 2005;33(1):81–88. doi: 10.1097/01.CCM.0000150028.64264.14. [DOI] [PubMed] [Google Scholar]
- 73.Morelli A, Ertmer C, Westphal M, Rehberg S, Kampmeier T, Ligges S, Orecchioni A, D'Egidio A, D'Ippoliti F, Raffone C, et al. Effect of heart rate control with esmolol on hemodynamic and clinical outcomes in patients with septic shock: a randomized clinical trial. JAMA. 2013;310(16):1683–1691. doi: 10.1001/jama.2013.278477. [DOI] [PubMed] [Google Scholar]
- 74.Sanfilippo F, Santonocito C, Morelli A, Foex P. Beta-blocker use in severe sepsis and septic shock: a systematic review. Curr Med Res Opin. 2015;31(10):1817–1825. doi: 10.1185/03007995.2015.1062357. [DOI] [PubMed] [Google Scholar]
- 75.Rushmer RF, Crystal DK. Changes in configuration of the ventricular chambers during the cardiac cycle. Circulation. 1951;4(2):211–218. doi: 10.1161/01.CIR.4.2.211. [DOI] [PubMed] [Google Scholar]
- 76.Sachdev A, Villarraga HR, Frantz RP, McGoon MD, Hsiao JF, Maalouf JF, Ammash NM, McCully RB, Miller FA, Pellikka PA, et al. Right ventricular strain for prediction of survival in patients with pulmonary arterial hypertension. Chest. 2011;139(6):1299–1309. doi: 10.1378/chest.10-2015. [DOI] [PubMed] [Google Scholar]
- 77.Buckberg G, Hoffman JI, Mahajan A, Saleh S, Coghlan C. Cardiac mechanics revisited: the relationship of cardiac architecture to ventricular function. Circulation. 2008;118(24):2571–2587. doi: 10.1161/CIRCULATIONAHA.107.754424. [DOI] [PubMed] [Google Scholar]
- 78.Ünlü S, Mirea O, Duchenne J, Pagourelias ED, Bézy S, Thomas JD, Badano LP, Voigt J-U. Comparison of feasibility, accuracy, and reproducibility of layer-specific global longitudinal strain measurements among five different vendors: a report from the EACVI-ASE strain standardization task force. J Am Soc Echocardiogr. 2018;31(3):374–380. doi: 10.1016/j.echo.2017.11.008. [DOI] [PubMed] [Google Scholar]
- 79.Yingchoncharoen T, Agarwal S, Popovic ZB, Marwick TH. Normal ranges of left ventricular strain: a meta-analysis. J Am Soc Echocardiogr. 2013;26(2):185–191. doi: 10.1016/j.echo.2012.10.008. [DOI] [PubMed] [Google Scholar]
- 80.Schmittinger CA, Dunser MW, Torgersen C, Luckner G, Lorenz I, Schmid S, Joannidis M, Moser P, Hasibeder WR, Halabi M, et al. Histologic pathologies of the myocardium in septic shock: a prospective observational study. Shock. 2013;39(4):329–335. doi: 10.1097/SHK.0b013e318289376b. [DOI] [PubMed] [Google Scholar]
- 81.Zhang H, Wang HY, Bassel-Duby R, Maass DL, Johnston WE, Horton JW, Tao W. Role of interleukin-6 in cardiac inflammation and dysfunction after burn complicated by sepsis. Am J Phys Heart Circ Phys. 2007;292(5):H2408–H2416. doi: 10.1152/ajpheart.01150.2006. [DOI] [PubMed] [Google Scholar]
- 82.Celes MR, Torres-Duenas D, Prado CM, Campos EC, Moreira JE, Cunha FQ, Rossi MA. Increased sarcolemmal permeability as an early event in experimental septic cardiomyopathy: a potential role for oxidative damage to lipids and proteins. Shock. 2010;33(3):322–331. doi: 10.1097/SHK.0b013e3181b38ef6. [DOI] [PubMed] [Google Scholar]
- 83.Supinski GS, Callahan LA. Hemin prevents cardiac and diaphragm mitochondrial dysfunction in sepsis. Free Radic Biol Med. 2006;40(1):127–137. doi: 10.1016/j.freeradbiomed.2005.09.025. [DOI] [PubMed] [Google Scholar]
- 84.Zang QS, Martinez B, Yao X, Maass DL, Ma L, Wolf SE, Minei JP. Sepsis-induced cardiac mitochondrial dysfunction involves altered mitochondrial-localization of tyrosine kinase Src and tyrosine phosphatase SHP2. PLoS One. 2012;7(8):e43424. doi: 10.1371/journal.pone.0043424. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Ersboll M, Valeur N, Mogensen UM, Andersen MJ, Moller JE, Velazquez EJ, Hassager C, Sogaard P, Kober L. Prediction of all-cause mortality and heart failure admissions from global left ventricular longitudinal strain in patients with acute myocardial infarction and preserved left ventricular ejection fraction. J Am Coll Cardiol. 2013;61(23):2365–2373. doi: 10.1016/j.jacc.2013.02.061. [DOI] [PubMed] [Google Scholar]
- 86.Fine NM, Chen L, Bastiansen PM, Frantz RP, Pellikka PA, Oh JK, Kane GC. Outcome prediction by quantitative right ventricular function assessment in 575 subjects evaluated for pulmonary hypertension. Circ Cardiovasc Imaging. 2013;6(5):711–721. doi: 10.1161/CIRCIMAGING.113.000640. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The authors declare they keep the files containing data safely stored; these will be available to the editor on request.