Dataset on comparing the corrosion indices of alum and ferric chloride coagulants with phosphate dose elevation

Mohammad Hadi Dehghani a,b,, Reza Ghanbari a, Zoha Heidarinejad c
PMCID: PMC6106702  PMID: 30148196

Abstract

The aim of this data was to assess and compare the corrosion indices of alum and ferric chloride coagulants in conventional coagulation process of water with elevation of phosphate dose. After preparing synthetic water samples, jar experiments were performed with elevation of different phosphate doses using alum and ferric chloride coagulants. Then, corrosion indices of Ryznar and Langelier of water samples were calculated. The results indicated that the values of Ryznar and Langelier index in the experimental samples were 7 and less than zero, and the water conditions were under saturated. The corrosion and precipitation indices indicated that the water samples can be considered as corrosive waters.

Keywords: Corrosion indices, Alum and ferric chloride coagulants, Water


Specifications Table

Subject area Water chemistry
More specific subject area Corrosion and coagulation
Type of data Tables, Figures
How data was acquired After preparing the synthetic water samples, different doses of phosphate were injected into jar glasses, 10 mg/L alum and ferric chloride were also added to the samples and finally the phosphate level of the samples was measured by DR/2000 Direct Read Spectrophotometer at the wavelength of 420 nm. Ryznar and Langelier corrosion indices were calculated for samples.
Data format Raw, analyzed
Experimental factors The qualitative parameters of the samples including alkalinity, electric conductivity, total suspended solids, temperature, bicarbonate and pH were performed by the instructions in Standard methods for the examination of water and wastewater, 20th edition [1], [2], [3], [4].
Experimental features The levels of physico-chemical parameters of the samples were determined.
Data source location Tehran University of Medical Sciences, Tehran, Iran.
Data accessibility The data are available with this article

Value of the data

  • The data can be beneficial for improving the quality of potable water with corrosion problems resulting from alum and ferric chloride coagulants.

  • The data can be helpful in the design and operation of conventional and advanced coagulation units in water treatment plants.

  • The data comparing the Langelier and Ryznar corrosion indices of alum and ferric chloride with elevation of phosphate dose in water samples indicated that the water conditions in the samples were under saturated.

1. Data

The datasets include 4 Tables and 8 Figures. The water corrosion indices used are summarized in Table 1. Table 2 indicates the mixing conditions and retention time of stages of coagulation, flocculation, and sedimentation in jar experiments. The results of jar test for assessing the effect of orthophosphate dose in alteration of water corrosion indices for alum and ferric chloride coagulants are presented in Table 3, Table 4.

Table 1.

A summary of the corrosion and water sedimentation indices used in this study [5], [6], [7], [8], [9], [10], [11], [12].

Equation Index value Water condition
Langelier saturation LSI = pH – pHs LSI > 0 Super saturated, tend to precipitate CaCO3
index (LSI) pHs = A + B – log (Ca2+) – log LSI = 0 Saturated, CaCO3 is in equilibrium
(Alk) pH <= 9.3
pHs = (9.3 + A + B) – (C + D) LSI < 0 Under saturated, tend to dissolve solid CaCO3
(3) pH > 9.3
Ryznar stability RSI = 2pHs – pH RSI < 6 Super saturated, tend to precipitate CaCO3
index (RSI) 6 < RSI < 7 Saturated, CaCO3 is in equilibrium
RSI > 7 Under saturated, tend to dissolve solid CaCO3

A = (Log10 (TDS) - 1) / 10 B = -13.12 × Log10 (°C + 273) + 34.5

C = Log10 (Ca2 as CaCO3) - 0.4 D = Log10 (Alkalinity as CaCO3)

Table 2.

The conditions of mixing and retention time of coagulation, flocculation, and sedimentation stages.

Parameter Flash mixing Flocculation Sedimentation
Mixing speed (rpm) 120 20
Time (minute) 2 20 30

Table 3.

The results of jar test for evaluating the effect of orthophosphate dose in altering the water corrosion indices; type of coagulant: aluminum sulfate (alum).

Sample Ryznar stability Index (RSI) Langelier saturation index (LSI) pHs pH TDS (mg/L) EC (μmhos/cm) T (0C) HCO3- (mg/L) ALK mg/L (CaCo3) Phosphate Dose mg/L (Po4)
Raw water 8.22 −0.31 7.91 7.6 276.48 432 18.5 115.9 95
Jar 1 8.67 −0.74 7.94 7.2 279.68 437 19.1 109.8 90 0
Jar 2 8.65 −0.73 7.93 7.2 279.04 436 19.1 109.8 90 0.5
Jar 3 8.73 −0.79 7.94 7.15 279.68 437 19.2 106.75 87.5 1
Jar 4 8.78 −0.84 7.94 7.1 279.04 436 19.2 106.75 87.5 1.5
Jar 5 8.75 –0.83 7.93 7.1 279.68 437 19.1 109.8 90 2.5
Jar 6 8.76 –0.83 7.93 7.1 279.68 437 19.2 108.58 89 3.5

Table 4.

The results of jar test for evaluating the effect of orthophosphate dose in changes of water corrosion indices; type of coagulant: ferric chloride.

Sample Ryznar stability index (RSI) Langelier saturation index (LSI) pHs pH TDS (mg/L) EC (μmhos/cm) T (0C) HCO3-(mg/L) ALK mg/L (CaCo3) Phosphate Dose (mg/L Po4)
Raw water 8.33 −0.37 7.97 7.6 277.12 433 17 115.9 95
Jar 1 8.84 −0.87 7.97 7.1 279.68 437 17.1 106.75 87.5 0
Jar 2 8.85 −0.88 7.98 7.1 280.68 438 17 106.75 87.5 0.5
Jar 3 8.88 −0.89 7.99 7.1 280.32 437 17.1 103.7 85 1
Jar 4 8.86 −0.88 7.98 7.1 279.68 437 17.1 106.75 87.5 1.5
Jar 5 8.95 −0.98 7.98 7 280.32 438 17 106.75 87.5 2.5
Jar 6 8.88 −0.89 7.99 7.1 280.32 438 17.1 103.7 85 3.5

The results of changes in water pHs in response to elevation of phosphate dose in coagulation by alum and ferric chloride are demonstrated in Fig. 1, Fig. 2. The changes in Langelier and Ryznar saturation indices in response to phosphate dose elevation in coagulation by alum and ferric chloride are shown in Fig. 3, Fig. 4, Fig. 5, Fig. 6. The results of comparing the changes in the Langelier and Ryznar saturation indices in response to elevation of phosphate dose in coagulation by alum and ferric chloride are shown in Fig. 7, Fig. 8.

Fig. 1.

Fig. 1

The changes in water pHs in response to increased phosphate dose elevation in coagulation by alum.

Fig. 2.

Fig. 2

The changes in water pHs in response to increased phosphate dose elevation in coagulation by ferric chloride.

Fig. 3.

Fig. 3

The changes in Langelier saturation index in response to phosphate dose elevation in coagulation by alum.

Fig. 4.

Fig. 4

The changes in Langelier saturation index in response to phosphate dose elevation in coagulation by ferric chloride.

Fig. 5.

Fig. 5

The changes in the Ryznar index in response to phosphate dose elevation in coagulation by alum.

Fig. 6.

Fig. 6

The changes in the Ryznar index in response to phosphate dose elevation in coagulation by ferric chloride.

Fig. 7.

Fig. 7

Comparison of changes in Langelier saturation index due to increased phosphate dosage in coagulation with alum and ferric chloride.

Fig. 8.

Fig. 8

Comparison of changes in Ryznar saturation index due to increased phosphate dosage in coagulation with alum and ferric chloride.

2. Experimental design, materials and methods

2.1. Chemical materials

All chemicals used, including Na2HPO4.2H2O, 14H2O, Al2(SO4)3, FeCl3. 6H2O, H2SO4, CH3COOH, and HCl, were purchased from Merck Co., Germany.

2.2. Design of experiments

Synthetic water samples were used for comparing the corrosion indices of alum and ferric chloride coagulants in conventional coagulation processes of water with phosphate dose elevation, synthetic water samples were used. To prepare the synthetic water sample, natural clay soil water utilized. For this purpose, first this soil was passed through a sieve with mesh 120 and then 1.5 mg/L of it was weighed by a balance and poured into the water sample. For homogenization, it was then stirred for 10 min. Next, the solution was kept still for 24 h and then stirred again. After 30 min of sedimentation, the top water was used for the experiments.

2.3. Jar experiments

The jar experiments (coagulation, flocculation, and sedimentation) were performed by standard jar test device (Sedimentation Jar test, AZTEC Environmental Control LTD) using six 1-L beakers at room temperature. All jars and pedals of mixing were washed by HCl before doing any experiment and then rinsed off by distilled water [13], [14], [15]. Addition of phosphate compounds was also performed during rapid mixing, one minute before or after injecting the coagulant (alum or ferric chloride). The phosphate compounds were injected as 0.5, 1, 1.5, 2, 2.5, 3, and 3.5 mg/L into jar glasses. However, no phosphate was added to any of the jar glasses across all jar tests so that the extent of residual metal in every situation would be determined. Further, 10 mg/L doses of alum and ferric chloride were used for conventional coagulation. Eventually, the jar samples were filtered by a syringe filter with 0.45 μm pores and the phosphate level of the samples was measured by DR/2000 Direct Read Spectrophotometer at the wavelength of 420 nm. Eventually, the Langelier and Ryznar corrosion indices were calculated by the equations in Table 1.

Furthermore, all of the qualitative parameters of the samples including alkalinity, electric conductivity, total suspended solids, temperature, bicarbonate and pH were performed by the instructions in Standard methods for the examination of water and wastewater, 20th edition. The pH of the samples was measured by pH meter (Metrohm Herisau) E520.

Acknowledgments

This research has been supported by the Tehran University of Medical Sciences, Tehran, Iran.

Footnotes

Transparency document

Transparency data associated with this article can be found in the online version at https://doi.org/10.1016/j.dib.2018.08.007.

Transparency document. Supplementary material

Supplementary material

mmc1.docx (11.5KB, docx)

.

References

  • 1.Rice E., Baird R., Eaton A A., Lenore S. 22nd ed. American Public Health Association, American Water Works Association, Water Environmental Federation; 2012. Standard Methods: for the Examination Water and Wastewater. (ISBN 978-087553-013-0, ISSN 55-1979) [Google Scholar]
  • 2.Heidarinejad Z., Hashemzadeh Z.,B., Feizabadi G.K., Asghari F.B., Radfard M., Akbarpour B., Saleh H.N., Faraji H. Data on quality indices of groundwater resource for agricultural use in the Jolfa, East Azerbaijan, Iran. Data Brief. 2018;19:1482–1489. doi: 10.1016/j.dib.2018.06.017. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Yousefi M., Dehghani M.H., Nasab S.M., Taghavimanesh V., Nazmara S., Mohammadi A.A. Data on trend changes of drinking groundwater resources quality: a case study in Abhar. Data Brief. 2018;17:424–430. doi: 10.1016/j.dib.2018.01.032. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Mohammadi A.A., Yaghmaeian K., Faraji H., Nabizadeh R., Dehghani M.H., Khaili J.K. Temporal and spatial variation of chemical parameter concentration in drinking water resources of Bandar-e Gaz City using geographic information system. Desalination Water Treat. 2017;68:170–176. [Google Scholar]
  • 5.Yousefi M., Najafi Saleh H., Mohammad A.A., Mahvi A.H., Ghadrpoori M., Suleimani H. Data on water quality index for the groundwater in rural area Neyshabur County, Razavi province, Iran. Data Brief. 2017;15:901–907. doi: 10.1016/j.dib.2017.10.052. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Abbasnia A., Yousefi N., Mahvi A.H., Nabizadeh R., Radfard M., Yousefi M., Alimohammadi M. Evaluation of groundwater quality using water quality index and its suitability for assessing water for drinking and irrigation purposes; case study of Sistan and Baluchistan province (Iran) Hum. Ecol. Risk Assess.: Int. J. 2018 [Google Scholar]
  • 7.Asghari F.B., Jaafari J., Yousefi M., Mohammadi A.A., Dehghanzadeh R. Evaluation of water corrosion, scaling extent and heterotrophic plate count bacteria in asbestos and polyethylene pipes in drinking water distribution system. Hum. Ecol. Risk Assess.: Int. J. 2018;24:1138–1149. [Google Scholar]
  • 8.Soleimani H., Abbasnia A., Yousefi M., Mohammadi A.A., Khorasgani F.C. Data on assessment of groundwater quality for drinking and irrigation in rural area Sarpol-e Zahab city, Kermanshah province, Iran. Data Brief. 2018;17:148–156. doi: 10.1016/j.dib.2017.12.061. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Yousefi M., Yaseri M., Nabizadeh R., Hooshmand E., Jalilzadeh M., Mahvi A.H., Mohammadi A.A. Association of hypertension, body mass index and waist circumference with fluoride intake; water drinking in residents of fluoride endemic areas, Iran. Biol. Trace Elem. Res. 2018 doi: 10.1007/s12011-018-1269-2. [DOI] [PubMed] [Google Scholar]
  • 10.Mohammadi A.A., Najafi Saleh H., Mahvi A.H., Alimohammadi M., Nabizadeh R., Yousefi M. Data on corrosion and scaling potential of drinking water resources using stability indices in Jolfa, East Azerbaijan, Iran. Data Brief. 2018;16:724–731. doi: 10.1016/j.dib.2017.11.099. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Yousefi M., Saleh H.N., Yaseri M., Mahvi A.H., Soleimani H., Saeedi Z. Data on microbiological quality assessment of rural drinking water supplies in Poldasht county. Data Brief. 2018;17:763–769. doi: 10.1016/j.dib.2018.02.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Yousefi M., Mohammadi A.A., Yaseri M., Mahvi A.H. Epidemiology of drinking water fluoride and its contribution to fertility, infertility, and abortion: an ecological study in West Azerbaijan Province, Poldasht County, Iran. Fluoride. 2017;50:343–353. [Google Scholar]
  • 13.Yousefi M., Arami S.M., Takallo H., Hosseini M., Radfard M., Soleimani H. Modification of pumice with HCl and NaOH enhancing its fluoride adsorption capacity: kinetic and isotherm studies. Hum. Ecol. Risk Assess.: Int. J. 2018:1–13. [Google Scholar]
  • 14.Ramavandi B., Farjadfard S. Removal of chemical oxygen demand from textile wastewater using a natural coagulant. Korean J. Chem. Eng. 2014;31:81–87. [Google Scholar]
  • 15.Ramavandi B. Treatment of water turbidity and bacteria by using a coagulant extracted from Plantago ovata. Water Resour. Ind. 2014;6:36–50. [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary material

mmc1.docx (11.5KB, docx)

Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES