Abstract
The purpose of this study was to verify whether the exercise modality (i.e., running and cycling) alters the magnitude of “anaerobic” capacity estimated by a single supramaximal effort (AC[La]+EPOCfast). Fourteen healthy men (age: 26±9 years) underwent a maximum incremental test and a supramaximal effort to exhaustion at 115% of the intensity associated with maximal oxygen uptake to determine the AC[La]+EPOCfast (i.e., the sum of both oxygen equivalents from the glycolytic and phosphagen pathways), performed on both a treadmill and cycle ergometer. The maximal oxygen uptake during running was higher (p = 0.001; large effect size) vs. cycling (48.9±3.9mL·kg-1·min-1 vs. 44.8±5.5mL·kg-1·min-1 respectively). Contrarily, the oxygen equivalent from the glycolytic metabolism was not different between exercise modalities (p = 0.133; small effect size; running = 2.35±0.48 L and cycling = 2.18±0.58 L). Furthermore, the “anaerobic” capacity was likely meaning fully (3.65±0.70 L) and very likely meaningfully (949.1±5.7 mL·kg-1) greater in running than cycling (3.81±0.71 L and 52.0±8.1 mL·kg-1). Additionally, the contribution of the phosphagen metabolism was higher (p = 0.001; large effect size) for running compared to cycling (1.6±0.3 L vs.1.3±0.3 L respectively). Therefore, the “anaerobic” capacity estimated by the sum of both oxygen equivalents from the glycolytic and phosphagen pathways during a supramaximal effort is influenced by exercise modality and is able to identify the difference in phosphagen metabolic contribution, based on the methodological conditions of this study.
Introduction
Physiological responses, such as blood lactate concentration ([La]), oxygen uptake (), slow component, and kinetics Off responses [1] are significantly altered by different exercise modalities (e.g., treadmill, cycle ergometer, rowing, and swimming) [2,3], due to variables which are inherent to each mode (i.e., active muscle mass, body position, motor pattern, and others). In addition, the magnitute of the effect of the exercise modality on physiological responses seems to be more evidencied during maximal intensities [3], thus, some metabolic parameters widely used to assess physical fitness (i.e., maximal oxygen uptake and maximal accumulated oxygen deficit) are also modified [4].
Regarding “anaerobic” assessment (i.e., non-mitochondrial metabolic pathways), the maximal accumulated oxygen deficit (MAOD) is considered the most accepted method to assess “anaerobic” capacity [2,5] and seems to be affected by the exercise modality [4,6,7]. Hill and Vingren [7] described that in moderately active women and men, the MAOD estimated in running is greater compared with cycling possibly due to the greater muscle mass that is active during running. In addition, Billat and co-workers [8] reported that the slow component is higher during cycling compared with running, which alters the linear intensity- relationship and consequently, MAOD determination. Thus, it is possible to infer the effect of muscle mass on MAOD assessment.
As a way of optimizing the “anaerobic” capacity estimation, Bertuzzi et al. [9] proposed an alternative method for assessing “anaerobic” capacity in a single supramaximal effort (AC[La]+EPOCfast) based on the sum of oxygen equivalents from the phosphagen (EPCr) and glycolytic (E[La]) energy pathways, describing that AC[La]+EPOCfast is similar and correlated with MAOD. The AC[La]+EPOCfast procedure proposed by Bertuzzi et al. [9] estimates the “anaerobic” capacity based exclusively on the fast component of excess post-exercise oxygen consumption (EPOCfast), enabling estimation of the EPCr, and on delta blood lactate concentration (i.e., peak lactate value minus baseline lactate value; Δ[La]), enabling estimation of the E[La], using methods proposed by Margaria et al. [10] and di Prampero and Ferretti [11], respectively.
In addition to the aforementioned study of Bertuzzi et al. [9], Zagatto et al. [12] and Miyagi et al. [13] reinforced the validity of AC[La]+EPOCfast for running and cycling respectively, showing that AC[La]+EPOCfast was also similar to MAOD and adding that exercise intensity at 115% of the intensity associated with maximal oxygen uptake () corresponded to the greatest intensity to determine the AC[La]+EPOCfast.
However, as the AC[La]+EPOCfast procedure is a recent method, further studies investigating certain factors that could affect the blood lactate response or excess post-exercise oxygen consumption are necessary, such as the active muscle mass during effort and consequently the effect of ergometers specificities. According to reports in the literature, running involves a greater amount of active muscles [14] and a lower magnitude of the slow component [2] compared to cycling [1,14], leading to an increased area from the EPOCfast [1]. It is also known that active muscle mass affects blood lactate concentration [7], and would consequently affect the glycolytic responses used to assess AC[La]+EPOCfast. In addition, as the “anaerobic” capacity is defined as the maximal amount of adenosine triphosphate resynthesized via non-mitochondrial pathways during a specific mode of short-duration maximal exercise [15], the “anaerobic” capacity must be measured in specific exercise testing according to training and sport modality. Therefore, it is hypothesized that different values of AC[La]+EPOCfast will be found when estimated in running and cycling. In addition, due the differences in muscles mass involved [2] and motion patterns specificities [4] of each modality, it is also expected different contributions of the energy systems between running and cycling, which are ergometers widely used to evaluate the physical fitness and like training mode. Therefore, the purpose of this study was to verify whether the exercise modality, i.e., running vs. cycling, affects the magnitude of AC[La]+EPOCfast.
Materials and methods
Subjects
Fourteen healthy male, (mean±SD: age 26±9 years, height 174.1± 4.9 cm, body mass 72.9±10.8 kg, body fat percentage 16.5±4.1%), participated voluntarily in this study. The individuals were involved in recreational physical exercise, but none were classified as trained and none were especially experienced in cycling or running. All participants were informed of the experimental risks and signed an informed consent form prior to the investigation in accordance with the Declaration of Helsinki. The experimental procedures, as well as the informed consent, were approved by the Research Ethics Committee of the Sao Paulo State University, Brazil (Protocol number 645.784/2014).
Experimental design
The participants performed five experimental trials that were separated by an interval of at least 48-h for recovery (Fig 1). The volunteers were required to refrain from exhaustive exercise, and alcohol and caffeine ingestion for 48-h prior to data collection. To eliminate any influence of circadian rhythm, each subject completed all trials at the same time period of the day in controlled environmental conditions regarding temperature (22.9 ± 1.3°C) and relative humidity (43.8 ± 6.3%). Participants were instructed to maintain the same diet throughout the study.
Fig 1. The study design required participants to attend the laboratory on five separate occasions.
The initial visit consisted of anthropometric measurements and familiarization with the ergometers; the second and fourth visits were carried out the randomized graded exercise test on ergometers and the remaining two visits were carried out the supramaximal tests.
Each participant performed the procedures on the electromagnetic braking cycle ergometer (Excalibur Sport, Lode, Groningen, Netherlands) and motorized treadmill (ATL, Inbramed, Inbrasport, Porto Alegre, RS, Brazil). During the first session, the body composition was measured by Dual Energy X-ray Absorptiometry (Discovery, Hologic, USA), followed by familiarization on the cycle ergometer (10 min at 100 W) and motorized treadmill (10 min at 8 km·h-1). The initial sequence of ergometers was randomized (motorized treadmill or cycle ergometer) and assessments for each ergometer were conducted in two consecutive sessions for the same ergometer.
Initially, a graded exercise test was performed to determine the maximal oxygen uptake () and the minimal intensity at which was reached (). Next, a supramaximal test was performed until voluntary exhaustion at 115% of (each ergometer) to determine AC[La]+EPOCfast [12,13]. For each test, the participants were verbally encouraged to perform maximal effort. For the treadmill running efforts, participants wore a chest harness with the rope attached to the ceiling to ensure maximal effort without the risk of falling.
Prior to each testing effort, the warm-ups were standardized at 100 W on the cycle ergometer and 8 km·h-1 on the treadmill, lasting five minutes. The tests started five minutes after the end of the warm-up.
Procedures
Measurement of physiological and metabolic parameters
During all tests, the respiratory responses were measured breath-by-breath using a stationary gas analyzer (Quark PFT, COSMED, Rome, Italy). The gas analyzer was calibrated before each test using an ambient air sample and a high-precision gas mixture (3.98% CO2, 16.02% O2 and balanced N2; White Martins Gases Industrials Ltda, Osasco, SP, Brazil), whereas the turbine was calibrated before each test and verified after each test using a 3-L calibration syringe (Hans-Rudolf, Kansas City, MO, USA) in accordance with the manufacturer’s instructions. In addition, in supramaximal efforts, the was measured for 10 min at rest (i.e., before warm-up) for the baseline assessment and for 7 minutes after the end of the test to assess the EPOCfast. For analysis of respiratory variables, data were smoothed every 5-s and interpolated every 1 second. Heart rate (HR) was measured by means of a transmitter belt coupled to the gas analyzer (Wireless HR Monitor, COSMED, Rome, Italy).
Blood samples were collected 3, 5, and 7 minutes after each effort and the highest [La] measured was assumed as the peak value for each test. In the supramaximal effort, blood samples were also collected at rest before any physical effort (i.e., after 10 minutes sitting) to measure the baseline lactate concentration. Blood samples (25μL) were collected from the ear lobe using heparinized capillary tubes and transferred to Eppendorf tubes containing 50μL of 1% sodium fluoride for subsequent electrochemical analysis of lactate (YSI 2300 STAT, Yellow Spring Instruments, Yellow Spring, Ohio, USA).
Maximal graded exercise tests
The graded exercise test (GXT) on the treadmill began at 8 km·h−1 with staged increments of 1.5 km·h−1 every 2 min until exhaustion (gradient set at 1%) [12,16]. The GXT in cycling started with an intensity corresponding to 100 W, with increments of 25 W each 2 min stage of the exercise until voluntary exhaustion or until the inability of the individual to maintain a cadence of 70–75 revolutions per minute (rpm). The graded exercise tests were designed to last between 8–12 min.
The Borg scale (6–20) [17] was used to assess the rating of perceived exertion (RPE) at the end of each stage of the GXT tests. The highest average of the (i.e., average of the during the final 30-s of each stage) attained during the test was considered as [18]considering the verification of a plateau in (variation in < 2.1 mL·kg−1·min−1 between the final and penultimate stage of exercise). As secondary criteria to consider , at least two of the following criteria were required to be observed: maximal HR (HRmax) ≥ 90% of predicted HRmax; respiratory exchange ratio (RER) ≥ 1.10; and peak lactate ≥ 8.0 mmol·L−1 [18]. If plateau or at least two criteria were not observed, a new test was applied. The exercise velocity (for treadmill) or power output (for cycler ergometer) at which the subject reached was considered as for each ergometer. If the final stage had not been completed, the was calculated using the equation proposed by Kuipers et al. [19].
Estimation of “Anaerobic” capacity through AC[La+EPOCfast] method
The AC[La+EPOCfast] was determined as suggested by Bertuzzi et al. [9] and considering the exercise intensity reported by Zagatto et al. [12] and Myiagi et al. [13].
Supramaximal efforts were performed at an intensity corresponding to 115% of determined for each ergometer [12,13]. The highest average of the during the final 20-s of supramaximal effort was considered as exhaustion ). The AC[La+EPOCfast] was assumed as the sum of the EPCr and E[La] [9,12,13]. In addition, the time-to-exhaustion was measured.
The EPOCfast was used to estimate the contribution of the EPCr, which was calculated using a bi-exponential fit [9,12,13]in OriginPro 9.0 software (OriginLab Corp., Microcal, Mass., USA)
where is the rate of oxygen uptake at time (t); is the rate of oxygen uptake at baseline; A is the amplitude; δ is the time delay; and τ is the time constant– 1 and 2 represent the fast and slow components, respectively–and EPOCfast was calculated by the product of A1 and τ1.
The contribution of the E[La] was estimated by the difference between the quantities of blood lactate concentration at peak and rest (i.e., Δ[La]), considering each 1 mmol·L−1 of accumulated lactate as equivalent to 3 mL O2·kg−1 [11].
Statistical analyses
Data are presented as means ± SD and confidence interval of 95% (CI95%). Initially, the Shapiro-Wilk test was used to verify the normality of the data. Next, the t-test for dependent samples was used to compare the variables obtained on the motorized treadmill and cycle ergometer. In addition, the effect size (ES) was calculated considering the threshold values for Cohen’s d statistical power as ≥0.2 (small), ≥0.5 (moderate), and ≥0.8 (large). The Pearson’s correlation test was used to verify the association between the variables. The coefficient of correlation was classified as very weak to negligible (0 <0.2), weak (0.2 <0.4), moderate (0.4 <0.7), strong (0.7 <0.9), and very strong (0.9 <1.0). Statistical significance was accepted when p<0.05.
As alternative analysis, magnitude-based inference analysis was also used. The raw outcomes were log-transformed before analysis to reduce non-uniformity of error[20]. Magnitude-based inference was used to determine the practical significance and smallest worthwhile changes (non-clinical inference) in the comparison of scores between the cycle ergometer and treadmill, using the method described by [21]. A Cohen’s unit of 0.2 was used to determine the smallest worthwhile value of change. Using a Microsoft Excel® spreadsheet designed for sports science research [22], mean effects and 90% confidence limits were estimated to establish the percentage likelihood of each experimental condition having a negative/trivial/positive effect. Thus, the changes in benefit were qualitatively evaluated as follows: 0.5%–5% = very unlikely; 5%–25% = unlikely; 25%–75% = possibly; 75%–95% = likely; 95%–99.5% = very likely; and >99.5% = most likely [20]. When the positive and negative values were both >5%, the inference was classified as unclear.
Results
All subjects reached the exhaustion criteria in the GXT and did not need to repeat the test. The time-to-exhaustion in the GXT was 12.8±3.1 min (CI95% = 10.9 to 14.5 min) on the cycle ergometer and 9.7±1.6 min (CI95% = 8.7 to 10.6 min) on the treadmill. The determined in the cycling was lower compared with the running (p = 0.018), whereas the values of [La] peak obtained in the GXT were higher in the cycling (p = 0.012). Physiological parameters measured during the GXT are presented in Table 1.
Table 1. Physiological variables determined in the graded exercise test on the cycle ergometer and motorized treadmill (n = 14).
| Variable | Cycling | Running | p-values |
|---|---|---|---|
| (mL·kg-1·min-1) | 44.7 ± 5.7 (41.5 to 48.0) | 49.2 ± 3.8** (47.0 to 51.4) | 0.018 |
| (W) | 233.3 ± 38.4 (211.2 to 255.55) | - | - |
| (km·h-1) | - | 13.7 ± 1.3 (13.0 to 14.4) | - |
| RER peak | 1.19 ± 0.07 (1.14 to 1.23) | 1.16 ± 0.05 (1.13 to 1.20) | 0.188 |
| HRmax (bpm) | 184.3 ± 6.4 (180.6 to 188.0) | 188.1 ± 8.7** (183.1 to 193.2) | 0.008 |
| [La] peak (mmol·L-1) | 10.0 ± 1.5 (9.1 to10.8) | 8.8 ± 1.7** (7.8 to 9.9) | 0.012 |
Values in means ± SD (CI95%). = Maximal rate of oxygen uptake. = Lowest intensity corresponding to the . RER peak = Peak respiratory exchange ratio. HRmax = Maximum heart rate. [La] peak = Lactate peak concentration.
*p< 0.05 in relation to the cycle ergometer.
**p< 0.01 in relation to the cycle ergometer.
The results of the supramaximal effort at 115% of determined in the cycling and running are presented in Table 2 and in Fig 2. The in cycling [43.3 ± 4.0 mL·kg-1·min-1 (CI 95% = 41.3 to 45.7 mL·kg-1·min-1)] was higher (p = 0.006) than running [48.0 ± 4.2 mL·kg-1·min-1 (CI 95% = 45.6 to 50.6 mL·kg-1·min-1)]. No significant differences were found for time-to-exhaustion for cycling [175.9 ± 22.0 s (CI 95% = 163.2 to 188.7 s)] and running [155.4 ± 43.2 s (CI 95% = 130.5 to 180.4 s)] (p = 0.114). The phosphagen pathway outcomes (A1, τ-1, and EPCr) were higher in the running compared with cycling(p≤0.04), except for blood lactate responses, oxygen equivalent estimated from the glycolytic pathway, and RPE. These statistical findings were also reported by magnitude-based inference analysis, describing higher meaningful values when measured in running, except for the E[La] expressed in absolute values (Liters of oxygen) which demonstrated a possibly negative inference (i.e., higher value in cycling), although the possibility of change was only 27%. In addition, significant correlations were found between parameters measured during cycling and running for blood lactate, E[La], A1, EPCr, and RPE.
Table 2. Comparison and relationship between the variables obtained in the supramaximal intensity efforts at 115% of on the cycle ergometer and motorized treadmill.
| Variables | Cycling | Running | p-value | Δ% | Effect size (Cohen’sd±90%CL) | %Chances (Negative/ Trivial/ Positive) |
Qualitative inference | Correlation Coefficient (95%CI) |
|---|---|---|---|---|---|---|---|---|
| [La] peak (mmol·L-1) | 11.6 ± 1.6 (10.7 to 12.5) |
11.5 ± 2.1 (10.28 to 12.7) |
0.811 | -0.09±1.36 | -0.09±0.33 | 28/65/7 | Unclear | 0.76** (0.20 to 0.86) |
| [La] rest (mmol·L-1) | 1.1 ± 0.4 (0.8 to 1.3) |
1.0 ± 0.3 (0.8 to 1.2) |
0.676 | -0.04±0.36 | -0.04±0.38 | 23/62/15 | Unclear | 0.59* (0.18 to 0.85) |
|
Δ[La] (mmol·L-1) |
10.5 ± 1.7 (9.6 to 11.5) |
10.5 ± 2.1 (9.2 to 11.7) |
0.884 | -0.05±1.21 | -0.06±0.27 | 5/76/18 | Likely Trivial | 0.82** (0.20 to 0.86) |
| E[La] (L) | 2.33 ± 0.49 (2.04 to 2.62) |
2.27 ± 0.51 (1.97 to 2.57) |
0.501 | -0.06±0.31 | -0.11±0.26 | 27/70/3 | Possibly negative | 0.816** (0.28 to 0.88) |
| E[La] (mL·kg-1) | 31.6 ± 5.0 (29.0 to 34.5) |
31.4 ± 6.3 (27.8 to 35.1) |
0.884 | -0.14±3.62 | -0.06±0.27 | 18/76/5 | Likely Trivial | 0.82** (0.21 to 0.86) |
|
A1 (mL·kg-1·min-1) |
19.3 ± 2.2 (18.0 to 20.5) |
20.4 ± 1.7** (19.4 to 21.3) |
0.045 | +1.06±1.78 | 0.44±0.35 | 0/12/88 | Likely Positive | 0.605* (0.23 to 0.87) |
| τ-1 (min) | 0.91 ± 0.10 (0.85 to 0.97) |
1.12 ± 0.13** (1.04 to 1.19) |
0.001 | +0.21±0.18 | 1.76±0.70 | 0/0/100 | Most likely Positive | -0.13 (-0.61 to 0.36) |
| EPCr (L) | 1.29 ± 0.34 (1.1 to 1.5) |
1.64 ± 0.27** (1.5 to 1.8) |
0.0001 | +0.35±0.23 | 0.93±0.32 | 0/0/100 | Most likely Positive | 0.74* (0.39 to 0.90) |
| EPCr (mL·kg-1) | 17.7 ± 3.2 (15.8 to 19.5) |
22.6 ± 2.2** (21.3 to 23.8) |
0.0001 | +4.94±3.37 | 1.28±0.44 | 0/0/100 | Most likely Positive | 0.27 (-0.26 to 0.67) |
|
RPE (arbitrary unit) |
18 ± 2 (16.1 to 18.7) |
17 ± 2 (16.6 to 18.7) |
0.819 | +0.08±1.19 | 0.05±0.25 | 5/79/15 | Likely Trivial | 0.83* (0.47 to 0.93) |
Values in means ± SD (CI95%). [La] peak = Lactate peak concentration. [La] rest = Lactate rest concentration E[La] = contribution of the glycolytic metabolism. Δ[La] = difference between the lactate peak and rest. EPCr = contribution of the phosphagen metabolism. A1 = amplitude 1 the bi-exponential adjustment. τ-1 = constant time1 the bi-exponential adjustment. RPE = rate of perceived exertion. ES = Effect Size. Δ% = percentage alteration. The quantitative chances were assessed qualitatively as follow: 0.5%–5% = very unlikely; 5%–25% = unlikely; 25%–75% = possibly; 75%–95% = likely; 95%–99.5% = very likely; and >99.5% = most likely. If the probabilities of the effect being substantially positive and negative were both > 5%, the effect was reported as unclear.
* = p< 0.05 in relation to the cycle ergometer.
** = p< 0.01 in relation to the cycle ergometer.
Fig 2. Comparison of the “anaerobic” capacity by blood lactate and EPOCfast (AC[La]+EPOCfast) values determined during cycling and running.
Left panels (A and C) correspond to mean and standard deviation values and Right panels (B and D) correspond to individual values. *p<0.05 compared to the cycling.
Concerning the “anaerobic” capacity magnitude estimated by AC[La+EPOCfast], higher values were also found in running compared with cycling (Fig 2), these findings being reinforced by the magnitude-based inference analysis that reported a likely positive effect of AC[La+EPOCfast] determined in running (89% chance of positive effect for AC[La+EPOCfast] expressed in absolute values and 98% when the value was expressed relative to body mass). In addition, a significant correlation was found (p = 0.0003 for AC[La+EPOCfast] expressed in absolute values and p = 0.020 when the value was expressed relative to body mass) between AC[La+EPOCfast] determined in the different exercise modalities. These results, as well as the individual AC[La+EPOCfast] data are showed in Fig 2. All raw data are presented at S1 Data spreadsheet.
Discussion
The present study aimed to verify whether the exercise modality affects the AC[La+EPOCfast]. The main findings were that in moderately active subjects, running on a treadmill allowed greater energetic contribution from the phosphagen metabolism pathway and higher “anaerobic” capacity, evidenced by AC[La+EPOCfast]. Conversely, the glycolytic metabolism pathway was not different in cycling and running. Based on these results, the initial hypothesis of the study (i.e., exercise modality would alter the AC[La+EPOCfast] as well as the energy systems contributions) was confirmed.
There are some studies in the literature reporting the effects of exercise modality on conventional MAOD [4,6,7]. The higher MAOD value in running can be attributed to the greater energy demand during supramaximal effort in this type of exercise [23], largely due to the greater muscle mass activated [7]. In fact, higher MAOD values are expected because the “anaerobic” capacity is related to the amount of muscle mass that is active during effort [4].
The “anaerobic” capacity estimated by AC[La+EPOCfast] is determined using a different method. While the conventional MAOD needs to apply several submaximal trials to fit a linear -intensity relationship, followed by a supramaximal effort to determine the accumulated oxygen deficit, in the AC[La+EPOCfast] the “anaerobic” capacity is estimated by the sum of the oxygen equivalents from the phosphagen and glycolytic pathways[9,12,13]. In addition to feasibility considering time-required efficiency, this method is also able to distinguish between contributions from the phosphagen and glycolytic metabolism pathways in its calculation. The “anaerobic” capacity estimated by AC[La+EPOCfast] was ~10% higher in running, while the EPCr was ~32% higher in running.
Some authors have described that mode of exercise can overestimate (i.e., uphill exercise) or underestimate (i.e., cycling) the magnitude of MAOD [4]. In addition, in the same exercise modality, such as running, the exercise performed uphill can reflect in greater MAOD values compared with horizontal running [2], mainly due to the different set of muscles used during horizontal running [24]. However, it is important to consider the definition of “anaerobic” capacity described by Green [15], assumed as “the maximal amount of ATP resynthesized via the anaerobic metabolism during a specific type of short-duration, maximal exercise”. Therefore, it is plausible to assume that the “anaerobic” capacity estimated by AC[La+EPOCfast] is ergometer-dependent and seems to be specific to exercise modality performed, instead of assuming that it is overestimated (i.e., running) or underestimated (i.e., cycling).
The procedure used to estimate each energetic contribution was responsive to identify statistical differences in EPCr between ergometers (Table 2). During the initial phase of EPOCfast, restoration of phosphocreatine stores is through metabolic processes that rely on [11]. As the EPCr is estimated based on amplitude and constant time for oxygen deficit (τ-1), a higher response during effort in running results in a higher amplitude and τ-1, with consequently greater EPCr. Some studies have used 7 min [13,25], ~10 min or until the values return to the rest values [9]. However, these studies have used mathematical adjustments similar to the present study and similar τ-1 values as well. In the study of Miyagi et al. [13], the τ1 values were 1.00±0.21 min and 1.09±0.20 min in cycling test-retest whereas Zagatto et al. [25] the values of τ-1 were 1.00±0.13 min in treadmill. Therefore, although the recovery time after the test may influence the results, in the present study the results were similar to those in the literature and did not appear to have been harmed.
As exercise during cycling and running involves different active muscle mass [6], this difference can promote a relationship between the response and actions of the involved muscles, with consequences in the different responses attributed to EPOCfast [1]. Carter et al. [26] showed that A1 was higher in running compared with cycling at different intensities, supporting the findings of the present study (Table 2). Greater A1 in running revealed that in the relationship at 115% of was higher when compared to cycling (evident in the ratio of peak shown in Table 2), which implies different absolute values of between different exercise modalities. In addition, it is possible to speculate that, the higher active muscle mass during running likely improves the use of phosphocreatine stored in muscle, resulting in greater overall EPCr for running compared to cycling.
In contrast, the E[La] measurement was not statistically different between modalities, as well as the peak and Δ[La] (Table 2). The absence of differences for E[La] between modalities might be, again, result of the muscle mass involved in cycling and running. While it was expected higher [La] for running due the greater muscle mass involved [7], that also may play an important role in lactate clearance capacity during the supramaximal effort (i.e., greater muscle mass involved) [27]. It has been shown that modes of exercise involving greater muscle mass during moderate exercise may present lower values of lactate for the same relative intensity due to greater lactate removal by the muscles involved in the task [27]. In addition, despite non-significant (p = 0.114), the time to exhaustion presented a clear trend to be greater in cycling than in running at supramaximal effort (175.9 ± 22.0 s vs 155.4 ± 43.2 s), which could have contributed to the similar values of peak [La] (since cycling involves less muscle mass than running).
One possible limitation of the present study is related to the study subjects; all healthy individuals who reported practicing recreational soccer, running, and cycling. Therefore, future investigations using the AC[La+EPOCfast] for maximum running and cycling efforts in specific populations of athletes, i.e., triathletes, cyclists, and runners that present higher performance on their specific training ergometers, would be of great value to sport science. It is worth noting that the protocols were only performed after previous familiarization with both ergometers, aiming to minimize the influences of the exercise modality. Another limitation might be associated with the equivalent of O2 in relation to [La] used in this research. This relationship cannot represent the exact stoichiometric relationship between the formation of lactate and ATP resynthesis [9].
Conclusion
We conclude that the exercise modality (running or cycling) affects the magnitude of “anaerobic” capacity determined thought AC[La+EPOCfast]. Additionally, in moderately active subjects, running on a treadmill allowed greater energetic contribution from the phosphagen metabolism pathway. Conversely, the glycolytic metabolism pathway was not different in cycling and running. This result, besides representing the need to be evaluated each modality in the respective ergometer avoiding transferences, it also enables athletes and coach to plan the training schedule according to the specific adaptation.
Supporting information
(XLSX)
Acknowledgments
The authors would like to thank FAPESP, for the financial support (process number 2013/12940-8) and for the scholarships to W.E.M. (process number 2014/02829-5) and F.M. (process number 2016/02683-6).
Data Availability
All relevant data are within the paper and its Supporting Information files.
Funding Statement
The authors would like to thank FAPESP, for the financial support (process number 2013/12940-8) and for the scholarships to W.E.M. (process number 2014/02829-5) and F.M. (process number 2016/02683-6). http://www.bv.fapesp.br/en/auxilios/83505/maximal-accumulated-oxygen-deficit-determination-using-a-single-supramaximal-exercise-effort-analys/.
References
- 1.Sousa A, Rodríguez FA, Machado L, Vilas-Boas JP, Fernandes RJ. Exercise modality effect on oxygen uptake off-transient kinetics at maximal oxygen uptake intensity. Exp Physiol. 2015;100: 719–729. 10.1113/EP085014 [DOI] [PubMed] [Google Scholar]
- 2.Noordhof DA, De Koning JJ, Foster C. The maximal accumulated oxygen deficit method: A valid and reliable measure of anaerobic capacity? Sport Med. 2010;40: 285–302. 10.2165/11530390-000000000-00000 [DOI] [PubMed] [Google Scholar]
- 3.Abrantes C, Sampaio J, Reis V, Sousa N, Duarte J. Physiological responses to treadmill and cycle exercise. Int J Sports Med. 2012;33: 26–30. 10.1055/s-0031-1285928 [DOI] [PubMed] [Google Scholar]
- 4.Hill DW, Vingren JL. Maximal accumulated oxygen deficit in running and cycling. Appl Physiol Nutr Metab. 2011;36: 831–838. 10.1139/h11-108 [DOI] [PubMed] [Google Scholar]
- 5.Medbø JI, Mohn aC, Tabata I, Bahr R, Vaage O, Sejersted OM. Anaerobic capacity determined by maximal accumulated O2 deficit. J Appl Physiol. 1988;64: 50–60. 10.1152/jappl.1988.64.1.50 [DOI] [PubMed] [Google Scholar]
- 6.Hill DW, Davey KM, Stevens EC. Maximal accumulated O2 deficit in running and cycling. Can J Appl Physiol. 2002;27: 463–478. [DOI] [PubMed] [Google Scholar]
- 7.Hill DW, Vingren JL. Effects of exercise mode and participant sex on measures of anaerobic capacity. J Sports Med Phys Fitness. 2014;54: 255–263. [PubMed] [Google Scholar]
- 8.Billat VL, Mille-Hamard L, Petit B, Koralsztein JP. The role of cadence on the VO2, slow component in cycling and running in triathletes. Int J Sports Med. 1999;20: 429–437. 10.1055/s-1999-8825 [DOI] [PubMed] [Google Scholar]
- 9.Bertuzzi RCM, Franchini E, Ugrinowitsch C, Kokubun E, Lima-Silva AE, Pires FO, et al. Predicting MAOD using only a supramaximal exhaustive test. Int J Sports Med. 2010;31: 477–481. 10.1055/s-0030-1253375 [DOI] [PubMed] [Google Scholar]
- 10.Margaria R, Edwards HT, Dill DB. The possible mechanisms of contracting and paying the oxygen debt and the role of lactic acid in muscular contraction. Am J Physiol. 1933;106: 689–715. [Google Scholar]
- 11.Di Prampero PE, Ferretti G. The energetics of anaerobic muscle metabolism: A reappraisal of older and recent concepts. Respir Physiol. 1999;118: 103–115. 10.1016/S0034-5687(99)00083-3 [DOI] [PubMed] [Google Scholar]
- 12.Zagatto AM, Bertuzzi R, Miyagi WE, Padulo J, Papoti M. MAOD Determined in a Single Supramaximal Test: A Study on the Reliability and Effects of Supramaximal Intensities. Int J Sports Med. 2016;37: 700–707. 10.1055/s-0042-104413 [DOI] [PubMed] [Google Scholar]
- 13.Miyagi WE, de Poli RA, Papoti M, Bertuzzi R, Zagatto AM. Anaerobic capacity estimated in a single supramaximal test in cycling: Validity and reliability analysis. Sci Rep. 2017;7: 42485 10.1038/srep42485 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Carey DG, Tofte C, Pliego GJ, Raymond RL. Transferability of Running and Cycling Training Zones in Triathletes: Implications for Steady-State Exercise. J Strength Cond Res. 2009;23. [DOI] [PubMed] [Google Scholar]
- 15.Green S. A definition and systems view of anaerobic capacity. Eur J Appl Physiol Occup Physiol. Springer-Verlag; 1994;69: 168–173. [DOI] [PubMed] [Google Scholar]
- 16.De Poli RDAB, Miyagi WE, Nakamura FY, Zagatto AM. Caffeine Improved Time to Exhaustion But Did Not Change Alternative Maximal Accumulated Oxygen Deficit Estimated During a Single Supramaximal Running Bout. Int J Sport Nutr Exerc Metab. 2016;26: 549–557. 10.1123/ijsnem.2016-0038 [DOI] [PubMed] [Google Scholar]
- 17.Borg GAV. Psychophysical bases of perceived exertion. Med Sci Sport Exerc. 1982;14: 377–381. 10.1249/00005768-198205000-00012 [DOI] [PubMed] [Google Scholar]
- 18.Howley ET, Bassett DR, Welch HG. Criteria for maximal oxygen uptake: review and commentary. Med Sci Sports Exerc. 1995;27: 1292–1301. 10.1249/00005768-199509000-00009 [DOI] [PubMed] [Google Scholar]
- 19.Kuipers H, Verstappen FT, Keizer HA, Geurten P, van Kranenburg G. Variability of aerobic performance in the laboratory and its physiologic correlates. Int J Sports Med. 1985;6: 197–201. 10.1055/s-2008-1025839 [DOI] [PubMed] [Google Scholar]
- 20.Hopkins WG, Marshall SW, Batterham AM, Hanin J. Progressive statistics for studies in sports medicine and exercise science. Med Sci Sports Exerc. 2009;41: 3–12. 10.1249/MSS.0b013e31818cb278 [DOI] [PubMed] [Google Scholar]
- 21.Batterham AM, Hopkins WG. Making meaningful inferences about magnitudes. Int J Sports Physiol Perform. 2006;1: 50–57. [PubMed] [Google Scholar]
- 22.Batterham AM, Cox AJ. Spreadsheets for analysis of controlled trials, with adjustment for a subject characteristic. Sportscience. Internet Society for Sport Science; 2006;10: 46–51. [Google Scholar]
- 23.Bangsbo J. Oxygen deficit: a measure of the anaerobic energy production during intense exercise? Can J Appl Physiol. 1996;21: 350–363-369. 10.1139/h96-031 [DOI] [PubMed] [Google Scholar]
- 24.Olesen HL, Raabo E, Bangsbo J, Secher NH. Maximal oxygen deficit of sprint and middle distance runners. Eur J Appl Physiol Occup Physiol. 1994;69: 140–146. [DOI] [PubMed] [Google Scholar]
- 25.Zagatto AM, Miyagi WE, de Barros Sousa FA, Gobatto CA. Relationship between anaerobic capacity estimated using a single effort and 30-s tethered running outcomes. PLoS One. Public Library of Science; 2017;12: e0172032. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Carter H, Jones AM, Barstow TJ, Burnley M, Craig A, Doust JH, et al. Oxygen uptake kinetics in treadmill running and cycle ergometry : a comparison. J Appl Physiol. 2000;89: 899–907. 10.1152/jappl.2000.89.3.899 [DOI] [PubMed] [Google Scholar]
- 27.Beneke R. Dependence of the maximal lactate steady state on the motor pattern of exercise. Br J Sports Med. 2001;35: 192–196. 10.1136/bjsm.35.3.192 [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
(XLSX)
Data Availability Statement
All relevant data are within the paper and its Supporting Information files.


