Skip to main content
Data in Brief logoLink to Data in Brief
. 2018 Sep 6;20:1269–1273. doi: 10.1016/j.dib.2018.08.208

Data on the estimating the risk of cancer due to some common radiographs in Tehran city

Mohammad Mirdoraghi a,, Amin Banaei b, Jafar Fatahi Asl c
PMCID: PMC6143744  PMID: 30238038

Abstract

The purpose of the data is to estimate the excessive risk of cancer due to some common radiographs in Tehran. The data were collected in 8 radiology centers in Tehran city and on 283 patients with eight radiographic views. To obtain the data, PCXMC 2.0 based on Monte Carlo calculations, has been used to calculate the effective dose of each organ, and annual effective dose. The effective dose, cumulative effective dose, number of radiographs per year and excessive cancer risk due to the type of radiographs calculated. The additional risk of lethal cancer resulting from these radiographs in the target population is about 14.81 cases of the total population of Tehran city in one year.

Keywords: Common radiographs, Risk estimation, Radiology, PCXMC 2.0, Cancer


Specifications table

Subject area Radiation protection and radiation biology.
More specific subject area Calculating the risk of cancer due to some common radiographs in Tehran city.
Type of data Tables
How data was acquired The data on the cumulative effective dose of the population was calculated by PCXMC 2.0 software, and then the excessive risk of cancer was determined by standard equations.
Data format Raw, Analyzed.
Experimental factors The cumulative effective dose of the population was analyzed according to the equations for the excessive risk of radiation-induced cancer.
Experimental features The excessive risk of radiation-induced cancer was determined.
Data source location Radiology wards in educational hospitals affiliated to AJA university, Tehran province, Iran.
Data accessibility The data are available with this article.

Value of the data

  • The data show that the number of excessive cancers due to the common radiographs for the entire population of Tehran city is 14.81 cases per year. Therefore, data can be used to reduce the number of unnecessary radiographs and ultimately reduce the amount of cancer in Tehran city.

  • The data is useful in demonstrating that the optimization of exposure factors including FOV, KVP, MAS and FSD could diminish the effective dose of patients in common radiographs. Therefore, more researches is needed to adjust the mentioned parameters to decrease the excessive risk of radiation-induced cancer in the current population.

  • The data can be used to show that a specialist in radiation protection and radiation biology should supervise the radiology ward in order to monitor patient safety, quality control and quality assurance of radiology machines; consequently, the effective dose and the number of excessive cancers due to the common radiographs would be decreased.

1. Data

In Table 1, the ESD, the mean of the exposure parameters used for each type of radiography is presented.

Table 1.

Exposure parameters in the common radiology procedures and ESD.

Radiology procedure Mean KVP Mean MAS FSD (cm) ESD (mGy)
chest (Anterior-Posterior view) 65 20 180 0.15
pelvic (Anterior-Posterior view) 85 48 100 5.4
abdomen (Anterior-Posterior view) 64 44 100 2.7
skull (Anterior-Posterior view) 73 17 100 2.2
Thoracic spine (Anterior-Posterior view) 76 40 100 4.6
lumbar (Anterior-Posterior view) 76 55 100 5.8
lumbar spine (Lateral view) 85 69 100 6.2
Thoracic spine (Lateral view) 80 54 100 5.1

Table 2 shows the effective dose, cumulative effective dose, the number of radiographs per year, and excessive risk of cancer.

Table 2.

Effective dose, cumulative effective dose, number of radiographs per year, and excessive risk of cancer from each radiography in the population of Tehran city in a year.

Radiology Procedure the annual number of X-ray examinations per 1000 population Number of radiographs in the total population The average effective dose Accumulative effective dose (Man-Sievert) The number of excessive cancers for the entire population of Tehran in one year
Chest 90.12 784,172 0.028 21.95 1.09
abdomen (Anterior-Posterior view) 11.28 98,065 0.87 85.3 4.26
pelvic (Anterior-Posterior view) 14.91 129,623 0.61 79.07 3.95
lumbar spine 24.9 216,473 0.385 83.34 4.167
skull 25.77 224,036 0.05 11.20 0.56
Thoracic spine 7.61 66,159 0.24 15.87 0.79

2. Experimental design, materials and methods

2.1. Data collection

Data were collected on the 283 patients (65% male, 35% female) in eight common radiographs including, chest (Anterior-Posterior view), pelvic (Anterior-Posterior view), abdomen (Anterior-Posterior view), skull (Anterior-Posterior view), thoracic spine (Anterior-Posterior view), Thoracic spine (Lateral view), lumbar spine (Anterior-Posterior view), lumbar spine (Lateral view). At first, the accuracy tests of measuring half layer absorption, the accuracy of voltage of X-ray tube, time, Milliampere-seconds (mAs) were performed using Barracuda dosimeter (Multi-Purpose Detector). Then, the output of the X-ray machine was recorded at a distance of 100 cm and a voltage of 80 kV for 3 times in order to decrease the potential error. Also, all radiation parameters (voltage of tube, milliampere-seconds, focus to skin distance (FSD), filter thickness, field-of-view size (FOV) were recorded for all patients. To estimate Entrance Surface Dose (ESD) of the patients, the following equation used [1], [2].

ESD=A×(KV/80)2×mAs×B/FSD2
  • A=The output of tube at a KV of 80 at 1 m distance from X-ray tube.

  • B=Correction factor based on IAEA report no. 457.

  • MAs=Milliampere-seconds applied.

  • FSD=focus to skin distance (cm).

2.2. Calculating the effective dose

In order to estimate the annual effective dose and effective doses of organs the radiation parameters i.e. KV, MA-S, FSD, filter thickness, FOV entered in the PCXMC 2.0 software, manufactured by STUK–Radiation and Nuclear Authority, Helsinki, Finland.

2.3. Risk assessment

In order to estimate the excessive risk of radiation-induced cancer, the cumulative dose of the study population is required. The number of radiographs per year in the current society was extracted from previous studies [3], [4], [5]. Data on the cumulative effective dose for eight radiographs using of scientific relationships based on the acceptance of linear no-threshold model were obtained. Then, the risk of excessive cancer for each radiography was determined by standard equations [6], [7].

The population of Tehran city is around 8,693,706 by the 2016 census [8].

Assuming that the frequency of radiographs in Tehran city is equal to the radiographic frequency in the country [9], the annual cumulative effective dose can be calculated for a specific radiography. Consequently, according to the following formula, the excessive risk of lethal cancer is obtained per 100,000 people [10], [11].

Excessiveriskoflethalcancer=%5×(ManSievert)

Conflict of interest

None to declare.

Footnotes

Transparency document

Transparency data associated with this article can be found in the online version at https://doi.org/10.1016/j.dib.2018.08.208.

Transparency document. Supplementary material

Supplementary material.

mmc1.docx (12.1KB, docx)

.

References

  • 1.Ofori K., Gordon S.W., Akrobortu E., Ampene A.A., Darko E.O. Estimation of adult patient doses for selected X-ray diagnostic examinations. J. Radiat. Res. Appl. Sci. 2014;7:459–462. [Google Scholar]
  • 2.Okoro O., Soleimani H., Mirdoraghi M. A review of the state of diagnostic reference levels for radiology in Iran. J. Biomed. Health. 2017;2:35–43. [Google Scholar]
  • 3.Law M., Ma W.-K., Lau D., Cheung K., Ip J., Yip L., Lam W. Cumulative effective dose and cancer risk for pediatric population in repetitive full spine follow-up imaging: how micro dose is the EOS microdose protocol? Eur. J. Radiol. 2018;101:87–91. doi: 10.1016/j.ejrad.2018.02.015. [DOI] [PubMed] [Google Scholar]
  • 4.Mirdoraghi M., Fatahi Asl J., Fatahi Asl J. Evaluation of radiation protection condition in educational hospital radiological centers of Ahwaz University of Medical Sciences. Paramed. Sci. Mil. Health. 2017;11:1–8. [Google Scholar]
  • 5.Mirdoraghi M., Abbasi S. Natural products with radiation protection function in radiotherapy. J. Biomed. Health. 2017;2:10–18. [Google Scholar]
  • 6.Siegel J.A., Pennington C.W., Sacks B., Welsh J.S. The birth of the illegitimate linear no-threshold model. Am. J. Clin. Oncol. 2018;41:173–177. doi: 10.1097/COC.0000000000000244. [DOI] [PubMed] [Google Scholar]
  • 7.Salminen E., Niiniviita H., Järvinen H., Heinävaara S. Cancer death risk related to radiation exposure from computed tomography scanning among testicular cancer patients. Anticancer Res. 2017;37:831–834. doi: 10.21873/anticanres.11385. [DOI] [PubMed] [Google Scholar]
  • 8.J. Mahdianpour, HR. Saremi, Investigating the quantitative, economic and housing indicators and predicting the population structure, housing prices, housing and needed up to the horizon 1410 for Tehran city, Faslnameyeh motaleate modereat shahri, 31 (2016) pp. 37–57.
  • 9.Asadinezhad M., Toossi M.T. Bahreyni. Doses to patients in some routine diagnostic X-ray examinations in Iran: proposed the first Iranian diagnostic reference levels. Radiat. Prot. Dosim. 2008;132:409–414. doi: 10.1093/rpd/ncn308. [DOI] [PubMed] [Google Scholar]
  • 10.Mathews J.D., Forsythe A.V., Brady Z., Butler M.W., Goergen S.K., Byrnes G.B., Giles G.G., Wallace A.B., Anderson P.R., Guiver T.A. Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. BMJ. 2013;346:f2360. doi: 10.1136/bmj.f2360. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Aubrecht G. Contemporary Physics Education Project; 2003. A Teachers Guide to the Nuclear Science Wall Chart. [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary material.

mmc1.docx (12.1KB, docx)

Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES