. 2018 Sep;23:44. doi: 10.1016/j.artres.2018.07.003

Corrigendum to “Estimation of maximal oxygen consumption and heart rate recovery using the Tecumseh sub-maximal step test and their relationship to cardiovascular risk factors” [Artery Research 18 (June 2017) 29–35]

Alun D Hughes 1,, Nish Chaturvedi 1
PMCID: PMC6166623  PMID: 31186818

The authors regret that the published article contained an error in Eqs. (2) and (3). The correct equations should be:

(Men)VO2max(AVD)=1.29·Load[kg.m.min1]Exerciseheartrate[bpm]60·e0.0088·age[y] (2)
(Women)VO2max(AVD)=1.18·Load[kg.m.min1]Exerciseheartrate[bpm]60·e0.0090·age[y] (3)

The authors would like to apologise for any inconvenience caused.