Noise in the intensive care unit and its influence on sleep quality: a multicenter observational study in Dutch intensive care units

Koen S Simons 1,9,, Eva Verweij 1, Paul M C Lemmens 2, Sam Jelfs 2, Munhum Park 3, Peter E Spronk 4, Johannes P C Sonneveld 5, Hilde-Marieken Feijen 6, Marijke S van der Steen 7, Armin G Kohlrausch 8, Mark van den Boogaard 9, Cornelis P C de Jager 1
PMCID: PMC6173893  PMID: 30290829

Abstract

Background

High noise levels in the intensive care unit (ICU) are a well-known problem. Little is known about the effect of noise on sleep quality in ICU patients. The study aim is to determine the effect of noise on subjective sleep quality.

Methods

This was a multicenter observational study in six Dutch ICUs. Noise recording equipment was installed in 2–4 rooms per ICU. Adult patients were eligible for the study 48 h after ICU admission and were followed up to maximum of five nights in the ICU. Exclusion criteria were presence of delirium and/or inability to be assessed for sleep quality. Sleep was evaluated using the Richards Campbell Sleep Questionnaire (range 0–100 mm). Noise recordings were used for analysis of various auditory parameters, including the number and duration of restorative periods. Hierarchical mixed model regression analysis was used to determine associations between noise and sleep.

Results

In total, 64 patients (68% male), mean age 63.9 (± 11.7) years and mean Acute Physiology And Chronic Health Evaluation (APACHE) II score 21.1 (± 7.1) were included. Average sleep quality score was 56 ± 24 mm. The mean of the 24-h average sound pressure levels (LAeq, 24h) was 54.0 dBA (± 2.4). Mixed-effects regression analyses showed that background noise (β = − 0.51, p < 0.05) had a negative impact on sleep quality, whereas number of restorative periods (β = 0.53, p < 0.01) and female sex (β = 1.25, p < 0.01) were weakly but significantly correlated with sleep.

Conclusions

Noise levels are negatively associated and restorative periods and female gender are positively associated with subjective sleep quality in ICU patients.

Trial registration

www.ClinicalTrials.gov, NCT01826799. Registered on 9 April 2013.

Electronic supplementary material

The online version of this article (10.1186/s13054-018-2182-y) contains supplementary material, which is available to authorized users.

Keywords: Noise, Sleep quality, Intensive care unit, Critical illness, RCSQ

Background

Recently, hospital noise and its potential negative influence on patient outcome has gained widespread attention among caregivers [1, 2]. Noise is generally expressed as sound pressure in decibels (dB), whereby often a correction is made for the frequency of the sound (called “A-weighting”) to account for the relative loudness of the sound as perceived by the human ear. Noise levels in ICUs have been found to be beyond acceptable levels with average daytime sound pressure levels of around 60 A-weighted decibels (dBA) and peak levels > 90 dBA, the equivalent of standing next to a highway [3, 4]. Even more relevant, nighttime sound pressure levels are only slightly lower with averages of around 50 dBA. These sound pressure levels clearly exceed those of 35 dBA recommended by the World Health Organization (WHO) for nighttime in hospitals [5]. In the ICU, different factors contribute to high sound pressure levels, including a large number of alarm-generating monitoring equipment, use of mechanical ventilators and around-the-clock activities by staff members [4, 6, 7]. Excessive noise may cause multiple auditory and non-auditory effects, of which sleep disturbances are thought to be the most deleterious [8]. Sleep disturbances occur frequently in the ICU, characterized by an increase in stage 2 sleep and a decrease in stage 3 and rapid eye movement (REM) sleep [9, 10]. Up to now, only a few studies have studied the potential relationship between excessive noise and disturbed sleep in a real ICU setting. Studies using polysomnography in ICU patients demonstrated that between 11 and 24% of arousals are caused by environmental noise [11, 12]. Although polysomnography is considered the gold standard for evaluating sleep, it is labor intensive and a burden for ICU patients. Moreover, it is notoriously difficult to interpret and may not adequately reflect subjective sleep [13, 14]. Furthermore, studies have been performed in a small number of patients and in single centers, thus limiting the generalizability of the findings. Also, the acoustic parameters that have been analyzed are conventional measures of sound level, indicative of physical changes in the sound field. To further quantify the effects of noise on humans, advanced parameters, such as loudness and restorative periods, defined as periods of relative quietness, may be more useful. We therefore set up a prospective, multicenter observational study aimed to determine the association between various acoustic parameters and subjective perceived sleep quality in ICU patients.

Methods

Study design

This was a prospective observational multicenter study in the ICUs of five teaching hospitals and one university medical center in the Netherlands (CinicalTrials.gov. number NCT01826799). These hospitals were Jeroen Bosch Ziekenhuis,‘s Hertogenbosch (JBZ), Radboud University Medical Center, Nijmegen (RadboudUMC), Gelre Ziekenhuizen, Apeldoorn (Gelre), Isala Klinieken, Zwolle (Isala), Onze Lieve Vrouwe Gasthuis, Amsterdam (OLVG) and Ziekenhuis Gelderse Vallei, Ede (ZGV). Sound recording equipment was installed in 2–4 patient rooms in every participating ICU. Characteristics of the participating ICUs and rooms were collected, such as year of construction, layout, number of beds, level, population (e.g. surgical or cardiothoracic) and number of patients per room.

Patients

ICU patients aged ≥ 18 years, admitted to one of the equipped rooms, were eligible after 48 h of admission to the ICU. Patients were not included if they were unable to understand Dutch or were unable to be assessed for sleep quality, defined as either a Richmond Agitation and Sedation Scale (RASS) score of − 2 or less or presence of delirium. Delirium detection was based on the Confusion Assessment Method for the ICU (CAM-ICU) three times daily.

Before study recruitment and enrolment, each patient and/or relative was given a full explanation of the study. Since this was an observational design and no actual sound recording was made inside the rooms that could be retraceable to individual patients, the need for informed consent was waived by the regional medical ethical committee (registration number MJ504, Medisch-Ethische Toetsing Onderzoek Patienten en Proefpersonen (METOPP), Tilburg, The Netherlands). Patient characteristics and demographics including relevant previous medical history, admission diagnosis, severity of illness score (expressed by the Acute Physiology And Chronic Health Evaluation (APACHE-)II score) and length of stay in the ICU were collected. Patients’ data were entered into a web-based electronic case record form by the research nurses of the participating hospitals and were only accessible by the investigators.

Sound measurements

A measurement European conformity (CE)-marked microphone (M23, Earthworks Inc., Milford NH, USA) connected to a laptop or PC, was placed in 2–4 patient rooms, above the patients’ head (2.1~2.4 m from the floor). Only if the patient became eligible were the sound data used for analysis. The data were coded and stored on a hard disk and were de-identified to prevent identification of persons by members of the project group.

Based on previous research, the primary measures of interest for comparing the different acoustic conditions between the six hospitals were the A-weighted time-averaged sound pressure level (LAeq) and the 10th percentile (L90) sound pressure level (A-weighted on fast-response mode), which is an estimate of background noise [4]. Furthermore, the occurrence rate of loudness peaks per hour, and the number and the average duration of restorative periods were recorded. A restorative period was defined as a continuous time interval of at least 5 min during which the sound pressure level (SPL) did not exceed the predefined threshold of 17.7 dBA above the L90 [4]. The threshold of 5 min was chosen to be the minimum time required for a patient to be able to go to sleep after a disturbance, and has been reported in the literature previously, while the 17.7 dB minimum relative sound level has been shown to be the average level needed to see an arousal in polysomnographic measurements of (healthy) persons exposed to ICU noise during sleep [15, 16].

The number of restorative periods per hour and their average duration were calculated. Longer restorative periods provide more opportunity for undisturbed sleep. The detection of loudness peaks was based on the psycho-physiological model by Chalupper and Fastl to ensure that the impact of peak sounds was assessed based on the auditory perception and expressed in units of sone [17]. Sone defines the sound level with respect to how the frequency sensitivity of the human ear changes with level, with us being less sensitive to lower frequency sounds at low sound levels, giving a metric that is perceptually more accurate yet harder to compute. A doubling of the sone level is equal to a doubling of the perceived loudness, unlike all of the other sound level measures reported in this paper, which are based on the logarithmic decibel scale. The rate was calculated either including all peaks or only peaks that had a minimum level of 10 sone, which is equivalent to a noise peak of at least 73 dB at 1 kHz. We calculated values for each parameter for three time periods: the whole day, day time (7 a.m.–11 p.m.), and night (11 p.m.–7 a.m.). Secondary measures of interest are presented and discussed in Additional file 1. Noise data were analyzed using Matlab version R2017a (The Mathworks Inc., Natick, MA, USA).

Sleep assessment

Patients’ sleep was evaluated using the validated Richards Campbell sleep questionnaire (RCSQ) [18]. This 5-item questionnaire is used to evaluate different aspects of sleep, namely perceived sleep depth, sleep latency, number of awakenings, efficiency and time awake. Each item is rated on a visual analog scale (VAS) (0–100 mm), whereby higher scores indicate better sleep. The mean of the scores on these 5 items represents the overall RCSQ score. Usually, one item, regarding whether the noise level is disturbing for sleep is also part of the questionnaire [19, 20] and therefore this item was added to the questionnaire. The RCSQ has proven to be a valid, non-invasive tool for sleep perception in the ICU [18]. A Dutch translation of the RCSQ was created and validated according to the principles of good translation. Sleep evaluation was started after patients were identified as eligible, and was continued for a maximum period of five nights. The RCSQ was filled in by the patient at around 7 a.m.. If the patient was not able to fill in the RCSQ, no score was recorded.

Statistical analysis

Data were compared using Student’s t test and proportions were compared using the chi-square test. To determine associations between variable noise parameters and sleep quality, exploratory hierarchical mixed-model regression analyses were performed specifying random intercepts for rooms in hospitals and for patients and selecting the best-fitting model using an automated model selection procedure based on the Akaike information criterion (AIC) [21, 22]. We based the calculation of p values on Satterthwaite estimated degrees of freedom and carried out the analyses on the data from the nighttime recordings between 11 p.m. and 7 a.m. The goodness of fit of the model was calculated based on the method described by Nakagawa and Schielzeth [23]. All statistical analyses were performed using SPSS version 20 (SPSS, IBM) and R (version 3.4.1, R Foundation for statistical computing, Vienna, Austria).

Results

A total of 71 patients fulfilled the criteria between April 2013 and August 2015 and were included in this study. Data on seven patients were removed from the final analysis due to missing audio data. Baseline characteristics of the remaining 64 patients can be found in Table 1. On average, patients were 63.9 ± 11.7 years old and 48 (68%) patients were male. Most participating ICUs had single-bed rooms and the daily visiting routine occurred at similar times (see Table 2).

Table 1.

Patient characteristics on inclusion; an = 62 due to missing data in 2 patients

Characteristic Patient cohort (n = 64)
Patient characteristics
 Male sex, (n (%)) 44 (69)
 Age (mean, SD) 63.9 (11.7)
 APACHE II score (mean, SD) 21.1 (7.1)
 SOFA score (mean, SD) 6.1 (3.7)
 ICU admission duration before inclusion (median days, IQR) 4 [3–10]
Admission category
 Respiratory 15 (23.4)
 Cardiology 2 (3.1)
 Medical 19 (29.7)
 Neurology 1 (1.6)
 Surgery 27 (42.2)
Prior history
 Cognitive dysfunction (n (%)) 4 (6.3)
 Delirium during ICU stay (n (%)) 12 (19.4)a
 Hearing problems (n (%)) 2 (3.1)
 Alcohol abuse (n (%)) 7 (10.9)
Current status
 Use of sedatives (n (%)) 11 (17.2)
 Isolation measures (n (%)) 17 (26.6)
 Ability to speak (n (%)) 47 (73.4)
 Invasive mechanical ventilation (n (%)) 20 (31.2)
 Mechanical ventilation duration (median days, n IQR) 12 (9–23)

APACHE Acute Physiology And Chronic Health Evaluation, SOFA Sequential Organ Failure Assessment

Table 2.

Hospital characteristics

Hospital Site 1 Site 2 Site 3 Site 4 Site 5 Site 6
Patients, n (%) 16 (25.0) 5 (7.8) 13 (20.3) 9 (14.1) 14 (21.9) 7 (10.9)
Year of ICU construction 2008 2013 2011 2003 2011 2000
Type of ICU Medical
Surgical
Medical
Surgical
Cardiothoracic
Medical
Surgical
Medical
Surgical
Cardiothoracic
Medical
Surgical
Neurosurgical
Cardiothoracic
Medical
Surgical
Number of beds 14 36 14 24 40 12
Number of beds per room 1 1 1 1 to 2-4 1 1
Nursing handovers, h 0700–1500–2300 0730–1530–2315 0730–1530–2300 0730–1500–2315 0700–1500–2300 0730–1500–2245
Medical handovers Not in patient rooms 0830–1700–2330 0800–1630–2300 0845–1500–2315 1000–1600–2300 Not in patient rooms

Sleep quality of the patients

No sleep evaluation was registered for five patients; finally, 151 nights of sleep were evaluated (mean 2.4 nights/patient). Average total sleep quality was 56 ± 24 mm and was not significantly different between the participating hospitals (Table 3). Based on the additional question of the RCSQ, noise was considered quite disturbing with an average VAS score of 34 mm, whereby a lower score indicates more disturbance. In 64 of 151 nights (42%), patients provided an answer to which noise they found was the most disturbing factor during their sleep. Patients found that monitor/equipment alarms were the most disturbing to sleep (28/64) followed by other (n = 21), staff speech (n = 9), and other staff activities (n = 6).

Table 3.

Results from the sleep evaluation per site and of all sites; average scores per item of the Richards Campbell sleep questionnaire (RSCQ) and the average overall RCSQ score are expressed as mean mm (SD)

Site number Sleep depth Falling asleep Awakening Return to sleep Sleep quality Average RCSQ score
1 50 (26) 67 (31) 59 (26) 52 (30) 59 (27) 57 (23)
2 64 (24) 54 (33) 66 (30) 56 (26) 69 (26) 62 (26)
3 52 (26) 44 (29) 50 (25) 48 (34) 46 (31) 48 (23)
4 46 (16) 56 (24) 49 (24) 50 (27) 51 (28) 50 (20)
5 61 (28) 64 (31) 65 (26) 59 (32) 60 (30) 62 (27)
6 60 (16) 67 (22) 61 (21) 56 (22) 65 (22) 62 (18)
All sites 54 (25) 60 (30) 58 (26) 53 (30) 57 (29) 56 (24)

Noise levels in participating ICUs

The mean of the 24-h average sound pressure level (LAeq, 24h) was 54.0 ± 2.4 dBA, with no significant differences between day and night (see Table 4 and Fig. 1). The L90 was 38.1 ± 4.0 dBA on average. Restorative periods occurred on average 1.2 times per hour during the day, increased to 2.4 during the night (p < 0.0001), whereby also the average duration of the restorative period significantly increased from 11.4 min during the day to 14.1 min during the night (p < 0.001, see Table 4). Loudness peaks with a minimum magnitude of 10 sone occurred 23.1 times per hour during the day, significantly decreasing to 6.0 times per hour during the night (p < 0.0001).

Table 4.

Averages (SD) for five selected noise level parameters for each hospital individually (nighttime) and averages for all hospitals during 24 h, day time (7am - 11pm), and night (11pm - 7am)

Auditory parameter Site 1 Site 2 Site 3 Site 4 Site 5 Site 6 Average
24 h Day Night
LAeq (dBA, SD) 46.3 (3.9) 47.1 (5.8) 51.7 (3.2) 51.5 (2.2) 49.8 (2.7) 50.7 (1.5) 54.0 (2.4) 55.1 (2.3) 49.2 (4.0)
L90 (dBA, SD) 35.9 (4.2) 37.8 (1.9) 42.0 (3.6) 43.6 (1.9) 36.2 (4.0) 40.0 (2.7) 38.1 (4.0) 39.1 (3.9) 38.4 (4.7)
Peaks10S (count, SD) 2.5 (3.3) 4.1 (4.3) 8.4 (7.0) 8.8 (6.2) 7.2 (6.6) 7.2 (4.1) 17.5 (8.0) 23.1 (10.1) 6.0 (6.1)
Average number of restorative periods (count, SD) 20.5 (5.9) 15.9 (8.6) 19.5 (4.8) 18.4 (5.4) 17.9 (7.7) 19.6 (6.2) 38.3 (12.5) 19.4 (9.5) 19.1 (6.4)
Average durations of restorative periods (min, SD) 12.6 (5.5) 11.6 (5.5) 17.6 (7.9) 10.6 (2.1) 15.1 (10.5) 13.8 (5.5) 12.9 (7.7) 11.4 (9.4) 14.1 (7.7)

LAeq A-weighted time-averaged sound pressure level, dBA A-weighted decibel in ICU, L90 10th percentile sound pressure level (A-weighted on fast-response mode), Peak10S hourly rate of loudness peaks of at least 10 sone

Fig. 1.

Fig. 1

The 24-h average sound pressure levels (LAeq,24h) for three recording periods: all (24 h, midnight to midnight); day (from 7 a.m. to 11 p.m.); night (from 11 p.m. to 7 a.m.)

Association between noise and sleep

Female patients rated their sleep quality on average 1.2 points higher than men (p < 0.01; see Fig. 2 and Additional file 1). The number of restorative periods per hour during the night also significantly positively contributed to sleep quality: with every additional restorative period (per hour), sleep quality significantly increased by 0.53 points (p < 0.01). Higher levels of the background noise (L90) significantly decreased sleep quality ratings by 0.51 points (p < 0.05) (Fig. 2). We identified conditional Rglmmc2 of 0.2; regression model diagnostics did not highlight violations of model assumptions. Note that we did not incorporate the additional RCSQ item, regarding which noise source was most disturbing for sleep, as the predictor or outcome variable in the regression analysis because we did not gather a sufficient number of data points to enable us to make reliable conclusions. A more elaborate description of the analyses and model diagnostics is provided in Additional file 1.

Fig. 2.

Fig. 2

Standardized regression coefficients for the best fitting model for sleep quality evaluated by the patients. Error bars indicate 95% confidence intervals. Standardized coefficients are expressed in units of standard deviations to enable easy assessment of which of the regression predictors imparts the largest changes in the regression outcome variable

Discussion

In this prospective multicenter, observational study, we showed that background noise was negatively associated with sleep, while gender (female) and the number of restorative periods were positively correlated with sleep quality. Patients’ perceived sleep quality was poor and did not differ between participating hospitals. Overall, noise levels were consistently above the values (< 35 dB LAeq day and night; < 40 dB LAFmax night) recommended by the WHO [5]. This is the first study to evaluate a link between subjective sleep quality and objective noise parameters in ICUs.

Sleep disturbances are very common in ICU patients [13]. As a risk factor for sleep disturbances [13], noise in ICUs is ubiquitous and is mainly caused by staff activity, machines and alarms [4].

Research on the relationship between noise and sleep arousals in ICU patients, thereby using polysomnography, shows that noise peaks > 80 dBA are associated with arousal from sleep and that noise is responsible for 11 to 24% of the total number of arousals [11, 12, 24]. More subjectively, patients themselves consider noise in the ICU to be disturbing to sleep [25].

We found that a higher L90 led to a moderate decrease in sleep quality. L90 is considered to be indicative of the background noise level, generated by, for example, air conditioning or computer ventilators [26]. The average nighttime value of L90 was 38.1 dBA, indicating that levels of background noise even exceed the threshold for average sound pressure levels stated by the WHO. Because the participating hospitals were different in design and layout, considerable differences were found in L90 between hospitals. Given that within-hospital L90 was not different between day and night, the observed differences cannot be attributed to differences in procedures and staff movement but must be due to the building characteristics. This finding underlines the importance of taking building properties into account when designing a new ICU. Average day and nighttime noise levels were comparable with others studies, whereby differences between day and night were only marginal [3, 4].

This is the first study showing a positive association between restorative periods and better sleep. Restorative periods occurred on average only 2.4 times per hour during the night, and the average duration of a restorative period was 14.1 min, which is indicative of the high number of peak noises. Since restorative periods are most frequently ended by high-level noisy events due to staff activity or speech [4], interventions aimed at reducing staff-generated noise appears to be a reasonable and achievable goal to improve sleep quality in critically ill patients. Additionally, since noise coming from alarms and monitors were found to be the most disturbing noise sources in our qualitative analysis, nighttime alarm modification may also be of additional value in improving sleep quality in critically ill patients.

Female patients expressed that they had better sleep compared to the male patients. Gender differences in subjective sleep quality in ICU patients have not been reported previously in the literature, however, studies in the general population generally indicate worse subjective sleep quality in women, compared to men [27]. Interestingly, in a large study on the effects of traffic noise on objective sleep and subjective sleep quality in healthy people, there were larger effects of noise on objective sleep parameters in men compared to women, whereas no clear differences were found in subjective sleep quality [28]. Future research on gender differences in sleep quality should further elucidate this finding.

In addition to pure physical properties of sound, we also analyzed the impact of noise peaks on human perception (also called loudness) by using a validated model [17]. Loudness peaks with a magnitude of at least 10 sone occurred significantly less during the night than during the day. It is noteworthy that the nighttime hourly rate of these peaks differed substantially between the participating hospitals, varying from 2.5 to 8.8. Without a source-specific analysis, it is difficult to pinpoint the source of these loud peaks and what causes this difference between participating hospitals.

Some limitations need to be addressed. First, we used the RCSQ as a measure of sleep quality instead of polysomnography. Although RCSQ is validated for the use with ICU patients, subjective evaluation of sleep quality is subject to different forms of bias, including recollection and response bias, which may specifically be true for ICU patients who are recovering from critical illness. However, the results of the sleep evaluations are in line with previous studies and the repetitive design of up to five measurements helps in reducing the impact of outliers. Moreover, the RCSQ is easily applicable and interpretable and is therefore easier to use in daily practice in contrast to polysomnography. Second, we included a relatively small group of ICU patients who were awake and able to communicate, thus selecting only a subgroup of less severely ill patients, which makes it difficult to generalize the findings of this study to the whole ICU population. Although sleep evaluation in sedated and/or delirious patients remains difficult, interventions aimed at improving sleep quality by addressing noise may also have beneficial effects in this other patient group. Third, we did not take the long-term outcomes of the patients into account. Therefore, negative effects on sleep may not necessarily lead to worse outcomes. However, other studies have clearly demonstrated an association between sleep deprivation and the development of delirium in ICU patients, which has a multitude of negative long-term consequences [29]. Moreover, even brief periods of sleep deprivation in the general population can have long-term negative consequences in immune and cognitive function and in hypertension and obesity [30].

Conclusions

Associations between various noise parameters and subjective sleep quality were found in this multicenter study, confirming the negative consequences of noise on the sleep quality in ICU patients and thereby strengthening the usefulness of noise-reducing strategies. Sleep quality in general was poor and did not differ between participating ICUs. Noise levels were high and periods of relative quietness occurred only rarely. Increasing the number of nighttime restorative periods appears to be a reasonable goal for improving patients’ sleep.

Additional file

Additional file 1: (164.1KB, pdf)

Detailed description of acoustical analysis and model selection. (PDF 164 kb)

Acknowledgments

Availability of data and materials

The datasets used and analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

AIC

Akaike information criterion

APACHE

Acute Physiology And Chronic Health Evaluation

dB

Decibel

dBA

A-weighted decibel Intensive Care Unit

L90

10th Percentile sound pressure level (A-weighted on fast-response mode)

LAeq

A-weighted time-averaged sound pressure level

LAeq, 24h

A-weighted time-averaged sound pressure level over 24 h

LAFmax

A-weighted sound pressure level on fast mode

METOPP

Medisch-ethische toetsing onderzoek bij patiënten en proefpersonen (regional medical ethical committee)

RASS

Richmond Agitation and Sedation Scale

RCSQ

Richards Campbell sleep questionnaire

REM

Rapid eye movement

SPL

Sound pressure level

VAS

Visual analog scale

WHO

World Health Organization

Authors’ contributions

Study concept and design: KS, EV, MP, CdJ. Acquisition of data: KS, EV, SJ, MP, PS, JS, HF, MS, MvdB. Statistical analysis: PL. Analysis and interpretation of data: KS, PL, SJ, MvdB, CdJ. Drafting of the manuscript: KS, PL, SJ. Critical revision of the manuscript for important intellectual content: all authors. Study supervision: AK, MvdB, CdJ. All authors read and approved the final manuscript.

Authors’ information

Munhum Park and Armin G. Kolhrausch were affiliated with Philips Research during the study design and data acquisition.

Ethics approval and consent to participate

The need for formal ethical approval was waived by the regional medical ethics committee (registration number MJ504, Medisch-Ethische Toetsing Onderzoek Patienten en Proefpersonen (METOPP), Tilburg, The Netherlands).

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests related to this study.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Koen S. Simons, Phone: +31-73-5533967, Email: k.simons@jbz.nl

Eva Verweij, Email: mail@evaverweij.net.

Paul M. C. Lemmens, Email: paul.lemmens@philips.com

Sam Jelfs, Email: sam.jelfs@philips.com.

Munhum Park, Email: munhum.pa@kmitl.ac.th.

Peter E. Spronk, Email: p.spronk@gelre.nl

Johannes P. C. Sonneveld, Email: j.p.c.sonneveld@isala.nl

Hilde-Marieken Feijen, Email: h.m.feijen@olvg.nl.

Marijke S. van der Steen, Email: steenm@zgv.nl

Armin G. Kohlrausch, Email: a.kohlrausch@tue.nl

Mark van den Boogaard, Email: mark.vandenboogaard@radboudumc.nl.

Cornelis P. C. de Jager, Email: p.de.jager@jbz.nl

References

  • 1.Darbyshire JL. Excessive noise in intensive care units. BMJ. 2016;353:i1956. doi: 10.1136/bmj.i1956. [DOI] [PubMed] [Google Scholar]
  • 2.Hinton L. The intensive care unit was so noisy I couldn't sleep. BMJ. 2016;353:i2150. doi: 10.1136/bmj.i2150. [DOI] [PubMed] [Google Scholar]
  • 3.Darbyshire JL, Young JD. An investigation of sound levels on intensive care units with reference to the WHO guidelines. Crit Care. 2013;17(5):R187. doi: 10.1186/cc12870. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Park M, Kohlrausch A, de Bruijn W, de Jager P, Simons K. Analysis of the soundscape in an intensive care unit based on the annotation of an audio recording. J Acoust Soc Am. 2014;135(4):1875–1886. doi: 10.1121/1.4868367. [DOI] [PubMed] [Google Scholar]
  • 5.Berglund B, Lindvall T, Schwela DH & World Health Organization Occupational and Environmental Health Team. Guidelines for community noise. 1999. http://www.who.int/iris/handle/10665/66217.
  • 6.Weinhouse GL, Schwab RJ. Sleep in the critically ill patient. Sleep. 2006;29(5):707–716. doi: 10.1093/sleep/29.5.707. [DOI] [PubMed] [Google Scholar]
  • 7.Gabor JY, Cooper AB, Crombach SA, Lee B, Kadikar N, Bettger HE, Hanly PJ. Contribution of the intensive care unit environment to sleep disruption in mechanically ventilated patients and healthy subjects. Am J Respir Crit Care Med. 2003;167(5):708–715. doi: 10.1164/rccm.2201090. [DOI] [PubMed] [Google Scholar]
  • 8.Basner M, Babisch W, Davis A, Brink M, Clark C, Janssen S, Stansfeld S. Auditory and non-auditory effects of noise on health. Lancet. 2014;383(9925):1325–1332. doi: 10.1016/S0140-6736(13)61613-X. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Friese RS, Diaz-Arrastia R, McBride D, Frankel H, Gentilello LM. Quantity and quality of sleep in the surgical intensive care unit: are our patients sleeping? J Trauma. 2007;63(6):1210–1214. doi: 10.1097/TA.0b013e31815b83d7. [DOI] [PubMed] [Google Scholar]
  • 10.Elliott R, McKinley S, Cistulli P, Fien M. Characterisation of sleep in intensive care using 24-hour polysomnography: an observational study. Crit Care. 2013;17(2):R46. doi: 10.1186/cc12565. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Cabello B, Thille AW, Drouot X, Galia F, Mancebo J, d'Ortho MP, Brochard L. Sleep quality in mechanically ventilated patients: comparison of three ventilatory modes. Crit Care Med. 2008;36(6):1749–1755. doi: 10.1097/CCM.0b013e3181743f41. [DOI] [PubMed] [Google Scholar]
  • 12.Freedman NS, Gazendam J, Levan L, Pack AI, Schwab RJ. Abnormal sleep/wake cycles and the effect of environmental noise on sleep disruption in the intensive care unit. Am J Respir Crit Care Med. 2001;163(2):451–457. doi: 10.1164/ajrccm.163.2.9912128. [DOI] [PubMed] [Google Scholar]
  • 13.Pisani MA, Friese RS, Gehlbach BK, Schwab RJ, Weinhouse GL, Jones SF. Sleep in the intensive care unit. Am J Respir Crit Care Med. 2015;191(7):731–738. doi: 10.1164/rccm.201411-2099CI. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Kaplan KA, Hirshman J, Hernandez B, Stefanick ML, Hoffman AR, Redline S, Ancoli-Israel S, Stone K, Friedman L, Zeitzer JM. When a gold standard isn't so golden: lack of prediction of subjective sleep quality from sleep polysomnography. Biol Psychol. 2017;123:37–46. doi: 10.1016/j.biopsycho.2016.11.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Stanchina ML, Abu-Hijleh M, Chaudhry BK, Carlisle CC, Millman RP. The influence of white noise on sleep in subjects exposed to ICU noise. Sleep Med. 2005;6(5):423–428. doi: 10.1016/j.sleep.2004.12.004. [DOI] [PubMed] [Google Scholar]
  • 16.Ryherd EE, Waye KP, Ljungkvist L. Characterizing noise and perceived work environment in a neurological intensive care unit. J Acoust Soc Am. 2008;123(2):747–756. doi: 10.1121/1.2822661. [DOI] [PubMed] [Google Scholar]
  • 17.Chalupper J, Fastl M. Dynamic loudness model (DLM) for normal and hearing-impaired listeners. Acta Acust United Acust. 2002;88:378–386. [Google Scholar]
  • 18.Richards KC, O'Sullivan PS, Phillips RL. Measurement of sleep in critically ill patients. J Nurs Meas. 2000;8(2):131–144. doi: 10.1891/1061-3749.8.2.131. [DOI] [PubMed] [Google Scholar]
  • 19.Frisk U, Nordstrom G. Patients' sleep in an intensive care unit–patients' and nurses' perception. Intensive Crit Care Nurs. 2003;19(6):342–349. doi: 10.1016/S0964-3397(03)00076-4. [DOI] [PubMed] [Google Scholar]
  • 20.Kamdar BB, Shah PA, King LM, Kho ME, Zhou X, Colantuoni E, Collop NA, Needham DM. Patient-nurse interrater reliability and agreement of the Richards-Campbell sleep questionnaire. Am J Crit Care. 2012;21(4):261–269. doi: 10.4037/ajcc2012111. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Wagenmakers EJ, Farrell S. AIC model selection using Akaike weights. Psychon Bull Rev. 2004;11(1):192–196. doi: 10.3758/BF03206482. [DOI] [PubMed] [Google Scholar]
  • 22.Greven S, Kneib T. On the behaviour of marginal and conditional {AIC} in linear mixed models. Biometrika. 2010;97:773–779. doi: 10.1093/biomet/asq042. [DOI] [Google Scholar]
  • 23.Nakagawa S, Schielzeth H. A general and simple method for obtaining R2 from generalized linear mixed-effects models. Methods Ecol Evol. 2013;4(2):133–142. doi: 10.1111/j.2041-210x.2012.00261.x. [DOI] [Google Scholar]
  • 24.Aaron JN, Carlisle CC, Carskadon MA, Meyer TJ, Hill NS, Millman RP. Environmental noise as a cause of sleep disruption in an intermediate respiratory care unit. Sleep. 1996;19(9):707–710. doi: 10.1093/sleep/19.9.707. [DOI] [PubMed] [Google Scholar]
  • 25.Hofhuis JG, Spronk PE, van Stel HF, Schrijvers AJ, Rommes JH, Bakker J. Experiences of critically ill patients in the ICU. Intensive Crit Care Nurs. 2008;24(5):300–313. doi: 10.1016/j.iccn.2008.03.004. [DOI] [PubMed] [Google Scholar]
  • 26.Cowan JP. Handbook of environmental acoustics. New York: Wiley; 1994. [Google Scholar]
  • 27.Fatima Y, Doi SA, Najman JM, Mamun AA. Exploring gender difference in sleep quality of young adults: findings from a large population study. Clin Med Res. 2016;14(3–4):138–144. doi: 10.3121/cmr.2016.1338. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Roosli M, Mohler E, Frei P, Vienneau D. Noise-related sleep disturbances: does gender matter? Noise Health. 2014;16(71):197–204. doi: 10.4103/1463-1741.137036. [DOI] [PubMed] [Google Scholar]
  • 29.Weinhouse GL, Schwab RJ, Watson PL, Patil N, Vaccaro B, Pandharipande P, Ely EW. Bench-to-bedside review: delirium in ICU patients - importance of sleep deprivation. Crit Care. 2009;13(6):234. doi: 10.1186/cc8131. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.McEwen BS. Sleep deprivation as a neurobiologic and physiologic stressor: allostasis and allostatic load. Metabolism. 2006;55(10 Suppl 2):S20–S23. doi: 10.1016/j.metabol.2006.07.008. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Additional file 1: (164.1KB, pdf)

Detailed description of acoustical analysis and model selection. (PDF 164 kb)

Data Availability Statement

The datasets used and analyzed during the current study are available from the corresponding author on reasonable request.


Articles from Critical Care are provided here courtesy of BMC

RESOURCES