Abstract
Visualization of the complex 3D architecture of myocardial scar could improve guidance of radio-frequency ablation in the treatment of ventricular tachycardia (VT). In this study, we sought to develop a framework for 3D holographic visualization of myocardial scar, imaged using late gadolinium enhancement (LGE), on the augmented reality HoloLens. 3D holographic LGE model was built using the high-resolution 3D LGE image. Smooth endo/epicardial surface meshes were generated using Poisson surface reconstruction. For voxel-wise 3D scar model, every scarred voxel was rendered into a cube which carries the actual resolution of the LGE sequence. For surface scar model, scar information was projected on the endocardial surface mesh. Rendered layers were blended with different transparency and color, and visualized on HoloLens. A pilot animal study was performed where 3D holographic visualization of the scar was performed in 5 swines who underwent controlled infarction and electroanatomic mapping to identify VT substrate. 3D holographic visualization enabled assessment of the complex 3D scar architecture with touchless interaction in a sterile environment. Endoscopic view allowed visualization of scar from the ventricular chambers. Upon completion of the animal study, operator and mapping specialist independently completed the perceived usefulness questionnaire in the six-item usefulness scale. Operator and mapping specialist found it useful (usefulness rating: operator, 5.8; mapping specialist, 5.5; 1–7 scale) to have scar information during the intervention. HoloLens 3D LGE provides a true 3D perception of the complex scar architecture with immersive experience to visualize scar in an interactive and interpretable 3D approach, which may facilitate MR-guided VT ablation.
Introduction
Late gadolinium enhancement (LGE) imaging in cardiovascular magnetic resonance (CMR) is a clinical gold standard for imaging of the myocardial scar [1]. LGE has been used to identify extent, volume, and characteristics of myocardial scar in patients with prior myocardial infarction [1, 2]. In particular, the detailed scar depiction of the LGE has been suggested to be useful for planning and guiding scar-related ventricular tachycardia (VT) ablation by characterizing location and extent of the scar [3, 4].
In the assessment of the VT substrate, understanding the 3D scar architecture is particularly important. Voltage mapping is performed to identify “conduction channels” in and around the scar that could represent the VT isthmus. In the histological study, conduction channels have been described as surviving fiber bundles embedded in myocardial scar areas that can be located at any level of the myocardial wall, with a variable thickness and 3D structure [5, 6]. 3D LGE provides a better understanding of the complex scar anatomy compared with voltage mapping alone for guiding the radio-frequency (RF) ablation for VT [3]. Therefore, visualization of the 3D scar is important for identification of VT substrate and guidance of RF ablation for VT treatment.
Augmented reality has been emerging for visualizing complex medical data, particularly during and planning medical procedures [7]. In particular, HoloLens (Microsoft, Redmond, WA) [8] has enabled visualization of complex medical data that can provide immersive experience to interactively explore the data in 3D space in the mixed-reality environment, and has been tested in various clinical scenarios [9, 10]. Augmented reality allows true 3D visualization that provides 3D depth perception, and opens up the possibility for interacting with the medical data without physical contact to assist while maintaining sterile environment and reduce the risk of infection.
In this study, we sought to develop a framework for 3D holographic visualization of the LGE images on augmented reality HoloLens to provide a true 3D perception of the scar architecture with a direct physician interaction in a sterile environment. A pilot animal study was performed to demonstrate the feasibility of using 3D HoloLens visualization of scar in electrophysiology study.
Related works
LGE for guidance of VT ablation
In structural heart disease, VT is usually caused by re-entry, involving an arrhythmogenic substrate in the region of ventricular scar from a prior myocardial infarction [11]. The extent of LGE has been reported to identify the arrhythmogenic substrate [12], and improves a risk stratification for implantable cardioverter defibrillator therapy [13, 14] in patients with ventricular arrhythmias. Scar border zone defined in LGE has shown good correlation with VT inducibility [15] and spontaneous ventricular arrhythmias [16–18]. Therefore, various studies used LGE for planning and guiding VT ablation by integrating LGE into clinical electroanatomic mapping system [3, 4]. Recent studies showed improved outcome of using MRI-guided VT ablation compared to the mapping only system [19, 20].
AR for guidance of interventional procedures
Augmented reality (AR) shows promise for supporting interventional procedures. After the first in-human example of creation of dynamic interactive holograms from intraprocedural data [21], various studies have explored the use of holographic augmentation in various interventional procedures such as invasive structural cardiac procedures [22], ultrasound-guided transcatheter aortic valve implantation [23], neurosurgery [24], endovascular intervention [9], and near-infrared fluorescence based image guided surgery [10]. In the field of electrophysiology, a recent study reports first in-human experience of projecting intra-procedural electrophysiology data into an interactive holographic display [25].
Stereoscopic 3D visualization of the anatomy
Stereoscopic visualization improves our understanding of the complex 3D structures. In the conventional 2D flat screen visualization, 3D objects are projected onto the 2D flat screen, and users must visualize the complex 3D structures in their minds to fully understand the geometry and their relations [26, 27]. 3D stereoscopic presentation of images allow having additional depth information and make it easier to detect diagnostically relevant shapes, orientations, and relative positions of anatomical features [28]. A recent study compared virtual 3D stereoscopic model vs. 2D flat screen projected images when learning the head and neck vascular anatomy, and showed that 3D stereoscopic model offers more effective and increased ability to correctly identify the anatomy [29].
Touchless interaction in operating room
Touchless human-computer interaction to augment operator’s experience in sterile environment is important in interventional and surgical procedures [30]. Various techniques have been developed for touchless interaction in the operating room by using stereo camera [31, 32], voice commands [33, 34], and structured-light sensor [35]. HoloLens allows a combination of gesture recognition and voice command which offers physicians high degree of flexibility in interacting during the intervention.
Materials and methods
We propose a framework for 3D holographic visualization based on the high-resolution 3D LGE images to generate a 3D myocardial scar model and visualize on HoloLens (Microsoft, Redmond, WA). An overview of the proposed framework is presented in Fig 1, and detailed processing pipelines for 3D volumetric and endocardial projection of the scar are presented in the following sections.
Myocardial geometry reconstruction
The initial step of the framework is reconstructing endo and/or epicardial surface meshes. Previous study showed that reconstructing ventricular geometry using variational implicit function-based method provides the most accurate model [36], therefore we used Poisson surface reconstruction which uses an implicit function framework [37]. Endocardial and epicardial contours were manually delineated from LGE images in all slices. Contours in all slices were merged into a set of point clouds for each surface. Clustering decimation was performed to organize point clouds based on the cell of 3D grid, followed by computing the surface orientation of all vertices based on the 10 nearest neighboring points in the point clouds. Endo/ epicardial triangular surface meshes were then generated using a Poisson surface reconstruction [37, 38].
Voxel-wise 3D scar rendering
Proposed framework for voxel-wise 3D scar rendered holographic visualization of the high-resolution LGE data is described in Fig 2. Endo and epicardial surface meshes were reconstructed as described in the previous section. Scar tissue was defined as voxels in the myocardium with a signal intensity greater than a full-width at half-maximum (FWHM) [39]. To preserve high-resolution information of LGE voxels, every single voxel of the scar was rendered into a cube which carries the actual resolution of the LGE scan. Any duplicated vertices and faces were removed to reduce the size of the rendered scar mesh. All layers of rendered surface and scar mesh were then blended with different transparency and color to enhance visibility and perception.
Surface projection of the scar
The framework for holographic scar visualization of projected surface model is described in Fig 3. Endocardial surface mesh was first created using a Poisson surface reconstruction as described in the previous section. LGE voxels in the subendocardial region (0–33% from endocardial to epicardial) was projected onto the endocardial points. Endocardial points with projected scar information were then transferred to a texture, which was followed by a texture mapping performed on the parametrized Poisson surface of the endocardial mesh. The proposed framework was implemented in Matlab (MathWorks, Natick, MA) and MeshLab (Visual Computing Lab–ISTI–CNR, Rome, Italy) [38].
Augmented reality system
Voxel-wise 3D scar rendered model and surface-projected scar model were generated as described in the previous section, which were then exported to Filmbox (FBX) file format on Blender (Blender Foundation, Amsterdam, Netherland) and was imported onto HoloLens using OneDrive (Microsoft, Redmond, WA) and visualized using a 3D Viewer Beta (Microsoft, Redmond, WA).
System performance
The system performance of the HoloLens while running the generated voxel-wise 3D scar and surface projected scar model were compared with the baseline performance on HoloLens while nothing was running. System on a chip (SoC) power, system power, frame rate, CPU and GPU usage percentage were reported for each case.
Pilot animal study
A pilot animal study was performed to test feasibility of using holographic 3D LGE visualization in an electrophysiology study. This study was carried out in strict accordance with the recommendations in the Guide for the Care and Use of Laboratory Animals of the National Institutes of Health. The protocol was approved by the Beth Israel Deaconess Medical Center’s Institutional Animal Care and Use Committee (Protocol Number: 100–2014; Boston, MA, USA). All experiments were performed under general anesthesia with isoflurane inhalation (1.5–2.5%) and mechanical ventilation (12–16 breaths/min with tidal volumes between 300-400ml), and animal was euthanized with pentobarbital sodium. Further details regarding animal welfare and ethics are detailed in S1 Supporting Information.
A flowchart of the pilot animal experiment is presented in Fig 4. Five swines underwent 180 minute balloon occlusion of the mid left anterior descending artery to create an ischaemia-reperfusion mediated myocardial infarction model [40, 41]. After the infarction, animals were recovered and survived for 8 weeks and underwent in-vivo CMR. High-resolution 3D LGE image was acquired with the low-dimensional-structure self-learning and thresholding reconstruction technique [42–45]. Detailed CMR imaging parameters are reported in the next section. Holographic 3D LGE models were created as proposed using the in-vivo CMR, and after several days of recovery, animals underwent electrophysiology study where VT substrate mapping was performed. After the procedure, ex-vivo CMR imaging was performed and higher-resolution holographic model was generated using the ex-vivo CMR.
In the electrophysiology study, electroanatomic mapping was performed to define the arrhythmogenic VT substrate. Prior to the mapping procedure, both operator and mapping specialist used HoloLens 3D LGE data to review ventricular geometry and myocardial scar architecture, the size and extent of the scar from the voxel-wise 3D scar model and endocardial surface-scar projected model. Upon completion of the study, operator and mapping specialist independently completed the perceived usefulness questionnaire [46] to assess the perceived usefulness of the HoloLens 3D LGE consisting of 6 items on a seven-point Likert scale (1: extremely unlikely– 7: extremely likely). The overall usefulness rating is reported as a mean score of all 6 usefulness items for both the operator and the mapping specialist.
CMR imaging
In-vivo and ex-vivo CMR imaging were performed to generate holographic 3D LGE models as described in the previous section. CMR imaging was performed using a 1.5 T Philips scanner (Philips Achieva, Best, Netherland) with a 32-element cardiac phased-array receiver coil. For in-vivo imaging, high-resolution 3D LGE images with random under-sampled accelerated acquisition [42–45] were acquired 15–25 minutes after injection of 0.2 mmol/kg gadobenate dimeglumine (MultiHance; Bracco Imaging, Milan, Italy). A respiratory navigator with adaptive acquisition window [47] was used for prospective motion correction. Imaging parameters were as follows: gradient echo imaging sequence; TR/TE = 6.1/2.7 ms; field of view = 270×270×112–280×280×112 mm3; flip angle = 25°; isotropic spatial resolution = 1.0×1.0×1.0 mm3. Ex-vivo imaging was performed using high-resolution 3D gradient echo sequence with the following imaging parameters: TR/TE = 17/8 ms; field of view = 130×130×100 mm3; flip angle = 25°, isotropic spatial resolution = 0.4×0.4×0.5 mm3.
Results
An extensive LGE was observed in the anterior-septal regions in 8 weeks-post myocardial infarction swine. The distribution of the LGE was complex, with the areas of transmural or near transmural scar and subendocardial sparring. The overall LGE volume was 9.2 ± 7.5% of the entire left ventricular myocardial volume, with the endocardial portion of the LGE corresponds to 34.8 ± 8.6% of the total scar volume. The percentage of the LGE area projected on the endocardial surface was 13.8 ± 9.4%. The endocardial LGE surface regions corresponded to the bipolar voltage amplitude < 1.5 mV in the electroanatomic mapping.
For the in-vivo voxel-wise 3D LGE models, the number of vertices were 19,849 ± 13,216 and the number of faces were 81,035 ± 58,794. For the ex-vivo voxel-wise models, the number of vertices were 300,308 ± 382,670 and the number of faces were 962,480 ± 1,311,111. For the surface rendered LGE models, the number of vertices were 7,217 ± 2,381 and the number of faces were 14,263 ± 4,737. The typical processing time of all models for a single animal was about 1–2 hours, most of which was used for performing manual delineation of endo- and epicardial contours. Except for the contour delineation, no process takes longer than several minutes. The overall processing time therefore can be significantly reduced by using automated left and right ventricle segmentation techniques.
The system performance of the HoloLens while running the generated 3D holographic LGE model was compared with the baseline and summarized in Table 1. Surface model that was used for the performance test consists of 7,586 vertices and 2 materials were located. Voxel-wise 3D model that was used for the performance test consists of 290,506 vertices and 3 materials were located. SoC and system power were slightly increased with voxel-wise whole-heart 3D model, but CPU, and GPU usage stayed at the similar level.
Table 1. System performance of HoloLens with the 3D LGE models.
Baseline | Surface-projected Model | Voxel-wise 3D Model | |
---|---|---|---|
SoC Power (%) | 56 | 65 | 73 |
System Power (%) | 60 | 70 | 74 |
Frame Rate (fps) | 60.05 | 60.1 | 60.05 |
CPU (%) | 35 | 34 | 44 |
GPU (%) | 16.81 | 28.76 | 25.12 |
Baseline (when nothing is running on the HoloLens), surface-projected model (when surface projected scar model is running on the HoloLens), and voxel-wise 3D model (when voxel-wise 3D model is running on the HoloLens) were compared for system on a chip (SoC) power, system power, frame rate, CPU, and GPU usage.
The demonstration of the holographic visualization of the 3D LGE data using the proposed frameworks was recorded on HoloLens and presented in Fig 5 and S1 Video. The 3D holographic visualization of the whole-heart voxel-wise 3D scar rendering and scar projected endocardial surface mesh are demonstrated in Fig 5A. The user could interactively explore 3D LGE myocardial scar by scaling, rotating, moving, and viewing from any perspective in the augmented reality environment that allows for the combination of holographic 3D LGE data interacting with any real-world environments, such as a surgical suite or patient’s body. Holographic 3D LGE data can be viewed in any environment.
Fig 5B represents the endoscopic view of the holographic 3D LGE with the whole-heart voxel-wise 3D LGE model. The user can view the scar from inside of the ventricular chambers. As user steps into the heart, the transparent epicardial surface layer becomes invisible and the inner scar architecture can be explored more in detail.
Fig 6 shows operator and mapping specialist view during the electrophysiology study. Both operator and mapping specialist found HoloLens 3D LGE useful (overall usefulness rating: operator, 5.8; mapping specialist, 5.5, on a scale from 1: extremely unlikely useful to 7: extremely likely useful; Fig 7) in the VT substrate mapping and RF ablation procedures. The operator could directly review holographic 3D LGE data with a touchless interaction in sterile environment, and without additional hardware installations. The operator could visually compare the detailed 3D scar information with electroanatomic mapping data by overlaying the holographic scar on the electroanatomic map or viewing side by side (Fig 6A). The mapping specialist could review scar information for navigating the electroanatomic mapping (Fig 6B). Examples of operator interacting with HoloLens 3D LGE are presented in S2–S4 Videos.
Discussion
We present a framework for 3D visualization of the high-resolution 3D LGE of myocardial scar in a holographic manner on the augmented-reality glass HoloLens. High-resolution 3D LGE sequence was used to image the myocardial scar, and 3D rendered LGE model was generated and visualized on HoloLens 3D Viewer Beta. HoloLens 3D LGE was tested in the swine model of myocardial infarction with electrophysiology study of arrhythmogenic substrate mapping. Operator and mapping specialist interacted with HoloLens 3D LGE to review the extent and the structure of 3D myocardial scar and compared with the electroanatomic mapping data. Both operator and mapping specialist found HoloLens 3D LGE useful with a usefulness rating of 5.8 and 5.5, on a scale from 1 to 7, respectively. Holographic visualization of the 3D LGE images provides a true 3D perception of the complex scar architecture with immersive experience to explore the 3D LGE in a more interactive and interpretable way.
Holographic visualization of the LGE images allows to attain touchless interaction with the clinical data in sterile environments, thereby permitting the operator to have increased control and manipulation over pre- or intra-procedural information. Due to a robust gesture tracking using a depth sensor and camera, a user can also operate a HoloLens with a gloved and soiled hand. The availability of such augmented reality technologies to potentially improve procedural efficacy may be useful in the future for complex procedures, and the proposed framework can also be applied in other interventional and surgical procedures.
HoloLens 3D LGE allows detailed scar depiction with a 3D perception. Flat-screen visualizations of the complex three-dimensional myocardial scar structure limit our understanding due to the lack of the depth perception. Understanding the complex 3D scar anatomy using stereoscopic 3D visualization enables operator and mapping specialist to have a clear plan for VT substrate mapping and RF ablation. The endoscopic view further assist operator for a detailed pre-procedural plan for the endocardial catheter mapping.
The current electrophysiology procedures are usually performed as a team of operator and a mapping specialist. Due to the sterility concerns, the operator does not have access to the mapping system inputs, which limits operator’s ability to directly interact with maps during the intervention. HoloLens will provide the operator a higher level of control and visibility and reduce the frustrations of miscommunication between the operator and the mapping specialist by offering touchless interaction. Furthermore, if integrated with the real-time electroanatomic data and the catheter position, it will improve image-based guidance and VT ablation outcome.
Augmented reality allows us to combine holographic 3D LGE data interacting with any real-world environments, and may in the future facilitate data fusion and exploration of the LGE and electroanatomic data to support planning and performing VT ablation. HoloLens also offers unique interactive capabilities between multiple individuals, which may support pre-procedural planning in a group.
Recent study reports significantly reduced procedural and fluoroscopy time when merging LGE into the clinical mapping system to perform VT ablation [19], although another study report no differences in procedural or fluoroscopy time [20]. We did not measure the procedural or fluoroscopy time in this study, however, the impact on having additional information about the myocardial scar may provide similar experience to operators.
We used ex-vivo imaging only for the development phase, and did not test during the intervention or evaluate for the usefulness. Modeling of ex-vivo images can be challenging due to very high spatial resolution (400×400×500 μm3 in the current study) and large data size. We showed that three-dimensional holographic visualization of high-resolution ex-vivo images of 400 μm is feasible on HoloLens. Further improvement of the in-vivo CMR imaging techniques will enable higher-resolution imaging and offer a detailed depiction of the myocardial scar in the augmented reality environment during the intervention.
Our animal study was a pilot study towards demonstrating the feasibility of data visualization, and we did not use HoloLens 3D LGE for guiding ablation in real-time. We did not use ablation success as an endpoint in our study. The questionnaire was performed by one operator and one mapping specialist; however, neither of the investigators were involved in developing the technology. The weight of the HoloLens is 579 g which may hamper interventional applications, and further design modification should be done to reduce weight and thereby improve comfort level during the intervention.
Supporting information
Acknowledgments
We thank Dr. Warren Manning and Jennifer Rodriguez for their editorial comments. We thank Patrick Pierce, RT, Beth Goddu, RT, and Sophie Berg, RN, for their help with the CMR scanning.
Data Availability
All relevant data are within the paper and its Supporting Information files.
Funding Statement
This work was supported by the National Institutes of Health [grant number 1R01HL129185, 1R21HL127650]; and the American Heart Association [grant number 15EIA22710040]. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
References
- 1.Kim RJ, Fieno DS, Parrish TB, Harris K, Chen E-L, Simonetti O, et al. Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. Circulation. 1999;100(19):1992–2002. [DOI] [PubMed] [Google Scholar]
- 2.Kim RJ, Chen E-L, Judd RM. Myocardial Gd-DTPA kinetics determine MRI contrast enhancement and reflect the extent and severity of myocardial injury after acute reperfused infarction. Circulation. 1996;94(12):3318–26. [DOI] [PubMed] [Google Scholar]
- 3.Dickfeld T, Tian J, Ahmad G, Jimenez A, Turgeman A, Kuk R, et al. MRI-Guided ventricular tachycardia ablation: integration of late gadolinium-enhanced 3D scar in patients with implantable cardioverter-defibrillators. Circ Arrhythm Electrophysiol. 2011;4(2):172–84. 10.1161/CIRCEP.110.958744 [DOI] [PubMed] [Google Scholar]
- 4.Andreu D, Berruezo A, Ortiz-Pérez JT, Silva E, Mont L, Borràs R, et al. Integration of 3D electroanatomic maps and magnetic resonance scar characterization into the navigation system to guide ventricular tachycardia ablation. Circ Arrhythm Electrophysiol. 2011;4(5):674–83. 10.1161/CIRCEP.111.961946 [DOI] [PubMed] [Google Scholar]
- 5.De Bakker J, Van Capelle F, Janse MJ, Wilde A, Coronel R, Becker AE, et al. Reentry as a cause of ventricular tachycardia in patients with chronic ischemic heart disease: electrophysiologic and anatomic correlation. Circulation. 1988;77(3):589–606. [DOI] [PubMed] [Google Scholar]
- 6.Fernández-Armenta J, Berruezo A, Andreu D, Camara O, Silva E, Serra L, et al. Three-dimensional architecture of scar and conducting channels based on high resolution ce-CMR: insights for ventricular tachycardia ablation. Circ Arrhythm Electrophysiol. 2013:CIRCEP. 113.000264. [DOI] [PubMed] [Google Scholar]
- 7.Giuseppe R, Wiederhold BK. The new dawn of virtual reality in health care: medical simulation and experiential interface. ARCTT. 2015:3. [PubMed] [Google Scholar]
- 8.Taylor AG. What Is the Microsoft HoloLens? Develop Microsoft HoloLens Apps Now: Springer; 2016. p. 3–7. [Google Scholar]
- 9.Kuhlemann I, Kleemann M, Jauer P, Schweikard A, Ernst F. Towards X-ray free endovascular interventions–using HoloLens for on-line holographic visualisation. Healthcare Technology Letters. 2017;4(5):184 10.1049/htl.2017.0061 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Cui N, Kharel P, Gruev V, editors. Augmented reality with Microsoft HoloLens holograms for near infrared fluorescence based image guided surgery Molecular-Guided Surgery: Molecules, Devices, and Applications III; 2017: International Society for Optics and Photonics. [Google Scholar]
- 11.John RM, Tedrow UB, Koplan BA, Albert CM, Epstein LM, Sweeney MO, et al. Ventricular arrhythmias and sudden cardiac death. The Lancet. 2012;380(9852):1520–9. [DOI] [PubMed] [Google Scholar]
- 12.Bello D, Fieno DS, Kim RJ, Pereles FS, Passman R, Song G, et al. Infarct morphology identifies patients with substrate for sustained ventricular tachycardia. Journal of the American College of Cardiology. 2005;45(7):1104–8. 10.1016/j.jacc.2004.12.057 [DOI] [PubMed] [Google Scholar]
- 13.Iles L, Pfluger H, Lefkovits L, Butler MJ, Kistler PM, Kaye DM, et al. Myocardial fibrosis predicts appropriate device therapy in patients with implantable cardioverter-defibrillators for primary prevention of sudden cardiac death. Journal of the American College of Cardiology. 2011;57(7):821–8. 10.1016/j.jacc.2010.06.062 [DOI] [PubMed] [Google Scholar]
- 14.Klem I, Weinsaft JW, Bahnson TD, Hegland D, Kim HW, Hayes B, et al. Assessment of myocardial scarring improves risk stratification in patients evaluated for cardiac defibrillator implantation. Journal of the American College of Cardiology. 2012;60(5):408–20. 10.1016/j.jacc.2012.02.070 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Schmidt A, Azevedo CF, Cheng A, Gupta SN, Bluemke DA, Foo TK, et al. Infarct tissue heterogeneity by magnetic resonance imaging identifies enhanced cardiac arrhythmia susceptibility in patients with left ventricular dysfunction. Circulation. 2007;115(15):2006–14. 10.1161/CIRCULATIONAHA.106.653568 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Fernández-Armenta J, Berruezo A, Mont L, Sitges M, Andreu D, Silva E, et al. Use of myocardial scar characterization to predict ventricular arrhythmia in cardiac resynchronization therapy. Europace. 2012;14(11):1578–86. 10.1093/europace/eus104 [DOI] [PubMed] [Google Scholar]
- 17.Roes SD, Borleffs CJW, van der Geest RJ, Westenberg JJ, Marsan NA, Kaandorp TA, et al. Infarct Tissue Heterogeneity Assessed With Contrast-Enhanced MRI Predicts Spontaneous Ventricular Arrhythmia in Patients With Ischemic Cardiomyopathy and Implantable Cardioverter-DefibrillatorCLINICAL PERSPECTIVE. Circulation: Cardiovascular Imaging. 2009;2(3):183–90. [DOI] [PubMed] [Google Scholar]
- 18.Scott PA, Morgan JM, Carroll N, Murday DC, Roberts PR, Peebles CR, et al. The Extent of Left Ventricular Scar Quantified by Late Gadolinium Enhancement MRI Is Associated With Spontaneous Ventricular Arrhythmias in Patients With Coronary Artery Disease and Implantable Cardioverter-DefibrillatorsClinical Perspective. Circulation: Arrhythmia and Electrophysiology. 2011;4(3):324–30. [DOI] [PubMed] [Google Scholar]
- 19.Andreu D, Penela D, Acosta J, Fernández-Armenta J, Perea RJ, Soto-Iglesias D, et al. Cardiac magnetic resonance–aided scar dechanneling: Influence on acute and long-term outcomes. Heart Rhythm. 2017;14(8):1121–8. 10.1016/j.hrthm.2017.05.018 [DOI] [PubMed] [Google Scholar]
- 20.Zghaib T, Ipek EG, Hansford R, Ashikaga H, Berger RD, Marine JE, et al. Standard Ablation Versus Magnetic Resonance Imaging–Guided Ablation in the Treatment of Ventricular Tachycardia. Circulation: Arrhythmia and Electrophysiology. 2018;11(1):e005973 10.1161/CIRCEP.117.005973 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Bruckheimer E, Rotschild C, Dagan T, Amir G, Kaufman A, Gelman S, et al. Computer-generated real-time digital holography: first time use in clinical medical imaging. European Heart Journal-Cardiovascular Imaging. 2016;17(8):845–9. 10.1093/ehjci/jew087 [DOI] [PubMed] [Google Scholar]
- 22.Bruckheimer E, Rotschild C. Holography for imaging in structural heart disease. EuroIntervention: journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2016;12:X81–X4. [DOI] [PubMed] [Google Scholar]
- 23.Currie ME, McLeod AJ, Moore JT, Chu MW, Patel R, Kiaii B, et al. Augmented reality system for ultrasound guidance of transcatheter aortic valve implantation. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2016;11(1):31–9. 10.1097/IMI.0000000000000235 [DOI] [PubMed] [Google Scholar]
- 24.Meola A, Cutolo F, Carbone M, Cagnazzo F, Ferrari M, Ferrari V. Augmented reality in neurosurgery: a systematic review. Neurosurgical review. 2017;40(4):537–48. 10.1007/s10143-016-0732-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Silva JN, Southworth MK, Dalal A, Van Hare GF, Silva JR. Improving Visualization and Interaction During Transcatheter Ablation Using an Augmented Reality System: First-in-Human Experience. Am Heart Assoc; 2017. [Google Scholar]
- 26.Hilbelink AJ. A measure of the effectiveness of incorporating 3D human anatomy into an online undergraduate laboratory. British Journal of Educational Technology. 2009;40(4):664–72. [Google Scholar]
- 27.Shaffer K. Teaching anatomy in the digital world. New England Journal of Medicine. 2004;351(13):1279–81. 10.1056/NEJMp048100 [DOI] [PubMed] [Google Scholar]
- 28.Held RT, Hui TT. A guide to stereoscopic 3D displays in medicine. Academic radiology. 2011;18(8):1035–48. 10.1016/j.acra.2011.04.005 [DOI] [PubMed] [Google Scholar]
- 29.Cui D, Wilson TD, Rockhold RW, Lehman MN, Lynch JC. Evaluation of the effectiveness of 3D vascular stereoscopic models in anatomy instruction for first year medical students. Anatomical sciences education. 2017;10(1):34–45. 10.1002/ase.1626 [DOI] [PubMed] [Google Scholar]
- 30.Mewes A, Hensen B, Wacker F, Hansen C. Touchless interaction with software in interventional radiology and surgery: a systematic literature review. International journal of computer assisted radiology and surgery. 2017;12(2):291–305. 10.1007/s11548-016-1480-6 [DOI] [PubMed] [Google Scholar]
- 31.Graetzel C, Fong T, Grange S, Baur C. A non-contact mouse for surgeon-computer interaction. Technology and Health Care. 2004;12(3):245–57. [PubMed] [Google Scholar]
- 32.Grange S, Fong T, Baur C, editors. M/ORIS: a medical/operating room interaction system. Proceedings of the 6th international conference on Multimodal interfaces; 2004: ACM.
- 33.Alapetite A. Speech recognition for the anaesthesia record during crisis scenarios. international journal of medical informatics. 2008;77(7):448–60. 10.1016/j.ijmedinf.2007.08.007 [DOI] [PubMed] [Google Scholar]
- 34.Perrakis A, Hohenberger W, Horbach T. Integrated operation systems and voice recognition in minimally invasive surgery: comparison of two systems. Surgical endoscopy. 2013;27(2):575–9. 10.1007/s00464-012-2488-9 [DOI] [PubMed] [Google Scholar]
- 35.Meng M, Fallavollita P, Habert S, Weidert S, Navab N. Device-and system-independent personal touchless user interface for operating rooms. International Journal of Computer Assisted Radiology and Surgery. 2016;11(6):853–61. 10.1007/s11548-016-1375-6 [DOI] [PubMed] [Google Scholar]
- 36.Prakosa A, Malamas P, Zhang S, Pashakhanloo F, Arevalo H, Herzka D, et al. Methodology for image-based reconstruction of ventricular geometry for patient-specific modeling of cardiac electrophysiology. Progress in biophysics and molecular biology. 2014;115(2):226–34. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Kazhdan M, Bolitho M, Hoppe H, editors. Poisson surface reconstruction. Proceedings of the fourth Eurographics symposium on Geometry processing; 2006: Eurographics Association. [Google Scholar]
- 38.Cignoni P, Callieri M, Corsini M, Dellepiane M, Ganovelli F, Ranzuglia G, editors. Meshlab: an open-source mesh processing tool. Eurographics Italian Chapter Conference; 2008.
- 39.Flett AS, Hasleton J, Cook C, Hausenloy D, Quarta G, Ariti C, et al. Evaluation of techniques for the quantification of myocardial scar of differing etiology using cardiac magnetic resonance. JACC Cardiovasc Imaging. 2011;4(2):150–6. 10.1016/j.jcmg.2010.11.015 [DOI] [PubMed] [Google Scholar]
- 40.Tschabrunn CM, Roujol S, Nezafat R, Faulkner-Jones B, Buxton AE, Josephson ME, et al. A swine model of infarct-related reentrant ventricular tachycardia: electroanatomic, magnetic resonance, and histopathological characterization. Heart Rhythm. 2016;13(1):262–73. 10.1016/j.hrthm.2015.07.030 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Whitaker J, Tschabrunn CM, Jang J, Leshem E, O’Neill M, Manning WJ, et al. Cardiac MR Characterization of Left Ventricular Remodelling in a Swine Model of Infarct Followed by Reperfusion. J Magn Reson Imaging. 2018. [DOI] [PubMed] [Google Scholar]
- 42.Akçakaya M, Basha TA, Goddu B, Goepfert LA, Kissinger KV, Tarokh V, et al. Low‐dimensional‐structure self‐learning and thresholding: Regularization beyond compressed sensing for MRI Reconstruction. Magnetic Resonance in Medicine. 2011;66(3):756–67. 10.1002/mrm.22841 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Akçakaya M, Rayatzadeh H, Basha TA, Hong SN, Chan RH, Kissinger KV, et al. Accelerated late gadolinium enhancement cardiac MR imaging with isotropic spatial resolution using compressed sensing: initial experience. Radiology. 2012;264(3):691–9. 10.1148/radiol.12112489 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Akçakaya M, Basha TA, Chan RH, Manning WJ, Nezafat R. Accelerated isotropic sub‐millimeter whole‐heart coronary MRI: Compressed sensing versus parallel imaging. Magnetic Resonance in Medicine. 2014;71(2):815–22. 10.1002/mrm.24683 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Basha TA, Akcakaya M, Liew C, Tsao CW, Delling FN, Addae G, et al. Clinical performance of high‐resolution late gadolinium enhancement imaging with compressed sensing. J Magn Reson Imaging. 2017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Davis FD. Perceived usefulness, perceived ease of use, and user acceptance of information technology. MIS quarterly. 1989:319–40. [Google Scholar]
- 47.Moghari MH, Chan RH, Hong SN, Shaw JL, Goepfert LA, Kissinger KV, et al. Free‐breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size. Magn Reson Med. 2012;68(6):1866–75. 10.1002/mrm.24210 [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All relevant data are within the paper and its Supporting Information files.