. 2015 Dec 8;5(4):476–483. doi: 10.1016/j.jshs.2015.12.001

Validity and reliability of three methods of stiffness assessment

Elizabeth C Pruyn a,*, Mark L Watsford a, Aron J Murphy b
PMCID: PMC6188913  PMID: 30356566

Abstract

Background

Stiffness is commonly assessed in relation to injury and athletic performance. The purpose of this research was to compare the validity and reliability of 3 in vivo methods of stiffness assessment using 1 cohort of participants.

Methods

To determine inter-day reliability, 15 female netballers were assessed for stiffness twice within 1 week using unilateral hopping (vertical stiffness), free oscillations of the calf, and myometry of various muscles of the triceps surae. To establish convergent construct validity, stiffness was compared to static and dynamic strength measurements.

Results

Test–retest stiffness results revealed that vertical stiffness produced moderate to high reliability results and myometry presented moderate to very high reliability. In contrast, the free oscillation technique displayed low to moderate reliability. Vertical stiffness demonstrated a significant correlation with rate of force development during a squat jump, whilst myometer stiffness measurements from 3 sites in the lower limb revealed significant correlations with isometric rate of force development. Further, significant negative correlations were evident between the eccentric utilisation ratio and various myometer stiffness results. No relationships were established between the free oscillation technique and any of the performance measurements.

Conclusion

These results suggest that vertical stiffness and myometry are valid and reliable methods for assessing stiffness.

Keywords: Calf stiffness, Free oscillation technique, Myometry, Myoton-Pro, Vertical hop test, Vertical stiffness

1. Introduction

In a mechanical context, stiffness refers to a body resisting an applied change in length.1, 2 Butler and colleagues3 explain that the concept of stiffness involves deformable bodies that store and return elastic energy. Relatively high stiffness in humans has previously been related to increased risk of repetitive stress injuries as well as soft-tissue injuries such as hamstring strains.4, 5, 6 Further, stiffness has been related to performance of stretch–shorten cycle activities.7, 8, 9, 10 Since athletes strive to remain injury free and to perform optimally, stiffness is an important screening marker for physiotherapists, coaches, strength and conditioning trainers, and other practitioners. As detailed by Hooke's Law, the force required to deform the body is equal to the spring constant multiplied by the distance of deformation.3 The spring constant relates to the innate stiffness of the body; thus, to calculate stiffness, the required force and the distance of deformation are measured. Many techniques have been successfully implemented to distinguish between relatively stiff or relatively compliant participants. These include ultrasonography,11 the quick-release technique,12, 13 the vertical hop test,1 myometry,14 and the free oscillation technique.15 The current study will focus on the latter 3, as they are relatively simple to administer, and allow for relatively large cohorts to be tested within restricted time frames. Situations such as these are particularly relevant when testing professional athletes or conducting large-scale field studies.

The vertical hop test was initially outlined by McMahon and Cheng1 and typically involves unilateral hopping on a force platform. Excellent levels of reliability have been reported16 and the test is logistically simple to administer requiring the measurement of only 2 mechanical parameters: ground reaction force (GRF) and centre of mass displacement (ΔCOM).17 Although relatively simple to administer, the nature of the calculation makes many assumptions. Firstly, it assumes that vertical stiffness (Kvert) remains constant during hopping. However, it has been reported that Kvert increases inversely with ground contact time,18 and linearly with hopping height.19, 20 Thus, inherent differences in hopping techniques between individuals may affect the reliability and validity of this measurement of stiffness.

A further assumption of the vertical hop test is that the human leg works as a single linear spring, and that all components of the leg equally contribute to Kvert. However, ankle joint stiffness was reported as the primary modulator of Kvert during hopping.20 Whilst this method involves some assumptions, it is a global, inclusive, and functional measurement of lower-body stiffness.

The free oscillation technique assesses the stiffness of a limb segment based on the assumption that human muscles behave like a damped spring system.15 This assumption suggests that if any perturbation is applied whilst under load, the system will oscillate at a damped natural frequency due to the nature of the muscle and tendon structures.21 In a damped spring system, when a perturbation is applied, the damping coefficient causes the subsequent oscillations to subside over time. The free oscillation technique for stiffness assessment has been widely used in previous studies15, 22, 23, 24 and has generally been proven to be valid and reliable.24 Whilst the validity and reliability of these methods have been proven to be strong, accessibility issues may arise due to the limited mobility of the assessment apparatus. Further, procedures often require the assessment of a maximum voluntary contraction prior to stiffness assessment, which requires a greater length of time per testing session.

A further method of stiffness measurement is through the use of a myometer, an electronic device that is capable of recording multiple characteristics related to muscular tone such as tension, elasticity, and stiffness.14 Muscle stiffness calculation by myometry involves a small perturbation from the device applied to the skin covering the muscle. An accelerometer then measures the deformation characteristics of the muscle and calculates stiffness using the damped natural oscillations exhibited by the recoil characteristics of the muscle.14, 25 Commonly reported myometer models include the Myoton-2, Myoton-3, and more recently, the Myoton-Pro.

The Myoton-2 reportedly has a high level of inter-observer repeatability14 and inter-day reliability.25 The sensitivity of the device25 and its ease of use14 have been commended; however, its weakness was that it was solely suitable for surface musculature.14 The Myoton-3 reportedly displays excellent absolute inter-day reliability26 and significant correlations when evaluating concurrent and predictive validity.27 Zinder and Padua28 also reported good reliability and construct validity, noting an advantage of the device was its ability to measure isolated muscles. The Myoton-Pro has shown very high to excellent within-day reliability, and good to high between-day reliability.29 However, to the best of the authors' knowledge, there are no previous reports of the validity of this device.

It is important to establish the reliability and validity of data collection techniques to ensure any subsequent results are true and consistent. Whilst there have been separate reports of validity and reliability for each individual technique, no previous literature has compared the 3 techniques using the same cohort of participants.24, 25 Further, no previous study has evaluated the validity and reliability of the Myoton-Pro device. Thus, the aim of the current study was firstly to determine the convergent construct validity when compared to performance variables and the inter-day reliability of a new device to measure stiffness (Myoton-Pro), and secondly to compare the inter-day reliability and convergent construct validity of the vertical hop test, myometry, and the free oscillation technique. Knowledge of validity and reliability can assist with sample size calculations, as well as contribute to study design and development of appropriate methodology for future studies.

2. Materials and methods

2.1. Participants

Fifteen females who competed at various levels of competitive netball in the 2012 season, including New South Wales State League and club A-grade, volunteered to participate in this study. Participants were excluded from the study if they had sustained an injury within 3 months of testing, or fell outside the age range of 18–35 years. The study was approved by the Human Research Ethics Committee of the University of Technology, Sydney, and a written informed consent was obtained from each participant.

2.2. Procedures

The participants were assessed for stiffness twice within 1 week. To avoid any possible effects of fatigue, testing was conducted at least 48 h after competition, and sessions were at least 24 h apart. In order to maintain consistency of measurements, stiffness was assessed using 3 methods in the same order (myometry, followed by the free oscillation technique, and followed by the vertical hop test) and at the same time of day on each occasion. The participants were instructed not to deviate from their regular training patterns. In addition, the participants completed various performance tests following stiffness assessment during the first session only, to determine the convergent construct validity of the stiffness assessment methods. Prior to the commencement of Session 1, the participants were weighed on digital scales (Tanita, Sydney, Australia) and body mass was recorded to the nearest 0.1 kg. A 5 min warm-up on a stationary bike was then conducted with a required power output of 100 W.

2.2.1. Static strength measurements

The maximum isometric force (MIF) and rate of force development (RFD) during a unilateral isometric calf raise was measured with participants positioned in a seated calf raise machine with a mechanical winch attached (Fig. 1A). Hip, knee, and ankle joints were aligned at 90°, with the winch adjusted to fix this position during contraction. The participants were instructed to produce maximal force against the knee pad as fast as possible, holding for 3 s. The force data were collected via the load cell (Chase Engineering, Perth, Australia) at a rate of 1000 Hz. MIF was calculated as the peak of the force curve, whilst isometric RFD (RFDiso) was determined as the peak value of the derivative of the force curve using a 5 ms interval.9 Two trials were completed on each leg, and the greatest MIF value for each limb was used to determine subsequent loads for stiffness assessment.

Fig. 1.

Fig. 1

Diagrammatic representation of the seated calf raise machine (A) with a winch attached for an isometric contraction of the lower leg, and (B) loaded with weight plates for the free-oscillation technique.

2.2.2. Dynamic strength measurements

The participants performed 2 counter-movement jumps (CMJ) on a 1-dimensional force plate (Onspot, Wollongong, Australia) which was calibrated to a series of known masses prior to commencement. CMJ technique was in accordance with previous methods.11 The researcher gave instructions to jump for maximum height, whilst keeping hands on hips during the jump and landing. Researchers did not intervene to adjust the knee angle during the eccentric phase of the jump. Participants also completed 2 squat jumps (SJ) using the same apparatus and guidelines as the CMJ; however, they were additionally instructed to squat to a knee angle of 90° (as checked by a goniometer) and hold for 3 s before jumping. The force curve was examined immediately following each SJ, to ensure that no eccentric movement occurred prior to the concentric movement. Jump height and RFD were determined from the force data for each jump, and the results from the jump with the greatest jump height were recorded for further analysis. To determine the elastic component contribution, the eccentric utilisation ratio (EUR) was calculated using CMJ height and SJ height:

EUR=CMJSJSJ×100 (1)

with a higher ratio indicating a greater contribution from the elastic component to CMJ performance.30

2.2.3. Vertical hop test

A vertical hop test was used to assess Kvert. The participants were instructed to hop unilaterally on the 1-dimensional force plate in time to a digital metronome (Seiko, Tokyo, Japan) set at 2.2 Hz.16, 19, 20 To eliminate the cushioning effect of footwear and any contribution from the upper body, the test was performed barefoot with participants' hands remaining on their hips throughout. Once steady-state hopping was achieved, 10 s of force data were collected at 1000 Hz. Trials were accepted if at least 3 hops were within ±2% of the prescribed frequency,16 with a re-trial performed if frequency criteria were not met. Each participant completed the test for both right and left legs. Kvert was calculated as the ratio of peak GRF to the maximum ΔCOM.16, 31 ΔCOM was calculated by a double integration of the acceleration curve and the integration constant was set to assume that the lowest COM point occurred at the same time as peak GRF.32 The mean stiffness score of 3 consecutive hops was divided by body mass to produce a score relative to individual size.

2.2.4. Free-oscillation technique

Calf stiffness (Kcalf) was assessed using the free oscillation technique (Fig. 1B).23, 24, 33 To isolate the musculature of the lower leg, the participants were positioned in the seated calf raise machine, with a prescribed load situated directly above the knee (Fig. 1B). Once an angle of 90° at both the knee and ankle joint was achieved, an external downward force of 100–200 N8, 10, 15 was rapidly applied to the system by the researcher setting the lower leg into oscillation.34 Since the perturbations were applied manually, slight magnitude variations were expected, but were not considered to alter stiffness values as an elastic system will oscillate at its natural frequency regardless of the magnitude of applied force.23 To reduce the effects of neural responses to the perturbation, the subjects were instructed not to intervene throughout the test. To assist, arms were positioned across their chest, the opposite foot was elevated, and eyes were closed during each trial. Force data were collected at 1000 Hz via a load cell situated beneath the metatarsals (Fig. 1B), and the force profile was analysed after every trial to ensure that oscillations were free from subject intervention.

Custom-made software was employed to calculate Kcalf. The damped oscillations (Fig. 2) were modelled to a second-order linear equation, and the damping coefficient was calculated using the natural frequency as outlined in the literature.24 Kcalf was determined by the following equations:

Kcalf=4mf2π2+c24m (2)
c=4πmfns (3)

where m is the mass of the system, f is the damped natural frequency (1/T; Fig. 2) and c is the damping coefficient (equation 2) where fn is the natural frequency of the system and s is the damping ratio.23

Fig. 2.

Fig. 2

Representation of resultant damped oscillations following the application of a perturbation during the free oscillation technique. T = time between successive peaks.

The assessment load was prescribed at 70% of the participants' previously determined MIF (Kcalf 70%). This load was selected as it has been demonstrated as the equivalent of maximal stiffness.15, 24 Further, an absolute load of 20 kg (Kcalf 20 kg) was also implemented unilaterally to provide the ability to compare the stiffness derived from a consistent load across all participants. Two trials were performed on each leg, with the mean score of the 2 accepted as the Kcalf for each condition.

2.2.5. Myometry

A myometer was used to measure the stiffness of 4 points on each of the participants' lower limbs: lateral gastrocnemius (LG), medial gastrocnemius (MG), soleus (SOL), and Achilles aponeurosis (ACH). To maintain consistency between participants and between days, assessment points were drawn with a marker, and identical points were measured on the second testing occasion. The participants were required to be barefoot with the lower leg exposed. Measurements were collected using the latest model of a hand-held myometer, the Myoton-Pro (Myoton AS, Tallinn, Estonia), and were measured under 3 different conditions: lying, standing, and contracted. Lying involved the participants lying prone on an assessment table, with feet hanging off the table at an ankle angle of 90°. Standing measurements involved participants standing in anatomical position. Measurements for the contracted condition were collected with participants positioned in the seated calf raise machine, maintaining a position where the ankle joint was 90° whilst performing an isometric contraction equivalent to 70%MIF. Visual feedback was provided to ensure that a contraction equivalent to 70%MIF was maintained.

Myometer measurements were achieved by holding the device immediately above the skin overlaying the assessment site. Once the desired position was achieved, a mechanical impact (duration: 15 ms; force: 0.3–0.4 N) was delivered to the muscle by a mechanical probe, causing the tissue to deform for a brief period of time. Following this, the resultant damped natural oscillations25 were recorded via an in-built accelerometer, sampled at 3200 Hz.26 Stiffness was calculated as the ratio between the force applied and the muscle deformation.26 Three consecutive measurements were taken at each site in each position, with the mean value used for analysis.

2.3. Statistical analysis

2.3.1. Reliability

To establish the inter-day reliability of each of the stiffness measurements, each test was assessed for systematic bias by determining paired differences by Student's t test. Indexes of relative reliability, the intra-class correlation (ICC),35 and absolute reliability, the coefficient of variation (CV)35, 36 were also calculated for each stiffness measurement. ICC results were interpreted based on the classification scale: very high (0.90–1.00), high (0.70–0.89), moderate (0.50–0.69), and low (0.26–0.49).37 Finally, percentage standard error of measurement (%SEM) was calculated to determine the precision of each stiffness measurement.

2.3.2. Convergent construct validity

Each set of data was tested for normality using the Shapiro–Wilk test. To determine the convergent construct validity of each of the stiffness measurements, Pearson's product moment correlations were investigated for 5 performance variables including static strength measures (MIF and RFDiso) and dynamic strength measures (CMJRFD, SJRFD, and EUR). Relationships have previously been established between stiffness and similar neuromechanical outputs,8, 15, 24 hence their inclusion to establish convergent construct validity. When compared to unilateral static strength measurements (MIF, RFDiso), left and right legs were considered individually, resulting in a sample size of 30. When compared to bilateral dynamic strength measurements (CMJRFD, SJRFD, EUR), the mean value of left and right stiffness measurements was taken, resulting in a sample size of 15. Pearson's r value was used to determine the strength of the relationship, with the p value indicating if the relationship was significant. The magnitude of the correlations were interpreted based on the scale: perfect (1.00), nearly perfect (0.90–0.99), very large (0.70–0.89), large (0.50–0.69), moderate (0.30–0.49), small (0.10–0.29), and trivial (0.00–0.09).38 For all procedures, statistical significance was accepted at an α level of 0.05.

3. Results

Fifteen female netballers (age: 23.51 ± 2.86 years; height: 1.71 ± 0.06 m; mass: 70.18 ± 8.19 kg) participated in this study. Mean stiffness values for each assessment method and each condition are reported in Table 1, Table 2. The results from Day 1 and Day 2 were compared to assess the test–retest reliability of each method. To determine the convergent construct validity of the methods, the stiffness results from Day 1 were compared to the MIF, RFDiso, CMJRFD, and EUR (Table 3) also collected on Day 1.

Table 1.

Summary of reliability results for vertical hop test and free oscillation technique.

Method Leg Stiffness (N/m/kg, mean ± SD) p value %SEM (95%CI) ICC (95%CI) CV (95%CI)
Day 1 Day 2
Vertical hop test Both 176.4 ± 40.7 172.4 ± 34.1 0.48 12.39 (9.9–16.7) 0.68 (0.43–0.84) 21.51 (17.1–28.9)
Left 175.7 ± 40.4 168.5 ± 34.0 0.43 14.23 (10.4–22.4) 0.60 (0.15–0.85) 21.71 (15.9–34.2)
Right 177.1 ± 42.3 176.3 ± 34.9 0.91 10.67 (7.8–16.8) 0.79 (0.48–0.92) 21.94 (16.1–34.6)
Free oscillations, 70%MIF Both 412.3 ± 57.8 397.2 ± 67.4 0.22 11.47 (9.1–15.4) 0.47 (0.13–0.70) 15.51 (12.4–20.9)
Left 417.8 ± 60.9 403.3 ± 63.4 0.40 11.18 (8.2–17.6) 0.48 (−0.02–0.79) 15.14 (11.1–23.9)
Right 406.9 ± 56.1 391.0 ± 72.8 0.38 12.16 (8.9–19.2) 0.47 (−0.03–0.79) 16.29 (11.9–25.7)
Free oscillations, 20 kg Both 440.6 ± 84.8 428.0 ± 70.4 0.37 12.31 (9.8–16.5) 0.54 (0.23–0.75) 17.94 (14.3–24.1)
Left 448.3 ± 104.1 451.8 ± 81.9 0.89 15.23 (11.2–24.0) 0.49 (0.00–0.80) 20.81 (15.2–32.8)
Right 432.8 ± 62.6 404.3 ± 48.6 0.02 7.38 (5.4–11.6) 0.73 (0.36–0.90) 13.39 (9.8–21.1)

Abbreviations: CI = confidence interval; CV = coefficient of variation; ICC = intra-class correlation; MIF = maximum isometric force; SEM = standard error of the mean.

Table 2.

Summary of reliability results for myometry under various conditions.

Position Tissue Stiffness (N/m, mean ± SD) p value %SEM (95%CI) ICC (95%CI) CV (95%CI)
Day 1 Day 2
Lying ACH 393.2 ± 55.9 383.8 ± 54.6 0.23 7.67 (6.1–10.3) 0.72 (0.49–0.86) 14.22 (11.3–19.1)
LG 347.5 ± 72.9 348.6 ± 69.0 0.72 3.34 (2.7–4.5) 0.98 (0.95–0.99) 20.39 (16.2–27.4)
MG 293.8 ± 41.6 293.5 ± 33.7 0.94 4.89 (3.9–6.6) 0.86 (0.73–0.93) 12.88 (10.2–17.3)
SOL 414.2 ± 68.9 402.5 ± 69.4 0.12 6.96 (5.5–9.4) 0.84 (0.69–0.92) 16.94 (13.5–22.8)
Standing ACH 515.6 ± 92.1 518.7 ± 95.5 0.77 7.75 (6.2–10.4) 0.83 (0.67–0.91) 18.14 (14.5–24.4)
LG 441.6 ± 116.4 439.1 ± 105.8 0.68 5.28 (4.2–7.1) 0.96 (0.92–0.98) 25.26 (20.1–34.0)
MG 355.8 ± 77.1 352.1 ± 75.4 0.51 6.08 (4.8–8.2) 0.93 (0.85–0.96) 21.53 (17.2–28.9)
SOL 587.5 ± 125.1 578.6 ± 113.6 0.40 6.88 (5.5–9.3) 0.89 (0.79–0.95) 20.49 (16.3–27.6)
SCRM ACH 465.8 ± 124.2 444.1 ± 130.5 0.13 11.83 (9.4–15.9) 0.83 (0.68–0.92) 28.00 (22.3–37.6)
LG 466.5 ± 135.7 424.2 ± 107.0 0.02 15.53 (12.4–20.9) 0.69 (0.45–0.84) 27.43 (21.9–36.9)
MG 365.5 ± 121.4 352.3 ± 131.2 0.42 17.41 (13.9–23.4) 0.77 (0.57–0.88) 35.23 (28.1–47.4)
SOL 567.6 ± 155.5 558.3 ± 138.8 0.38 7.15 (5.7–9.6) 0.93 (0.86–0.97) 26.18 (20.9–35.2)

Abbreviations: ACH = achilles aponeurosis; CI = confidence interval; CV = coefficient of variation; ICC = intra-class correlation; LG = lateral gastrocnemius; MG = medial gastrocnemius; SCRM = seated calf raise machine; SEM = standard error of the mean; SOL = soleus.

Table 3.

Summary of performance test results (mean ± SD).

Performance test Result
MIF (kg) 75.3 ± 19.0
RFDiso (N/s) 2352.0 ± 1014.8
CMJ height (m) 0.23 ± 0.04
CMJRFD (N/s) 8888.5 ± 2955.4
SJ height (m) 0.22 ± 0.04
SJRFD (N/s) 6612.3 ± 2315.8
EUR 8.22 ± 9.23

Abbreviations: CMJ = countermovement jump; CMJRFD = countermovement jump rate of force development; EUR = eccentric utilisation ratio; MIF = maximum isometric force; RFDiso = isometric rate of force development; SJ = squat jump; SJRFD = squat jump rate of force development.

Comparison of Day 1 vs. Day 2 stiffness results revealed that the vertical hop test produced moderate to high relative reliability results, whilst the results for the free oscillation technique at both 70%MIF and 20 kg were low to moderate (Table 1). Relative reliability results for the myometer were moderate to very high with ICC values ranging from 0.69 to 0.98 for the various conditions (Table 2). Further, myometer results collected in lying and standing positions showed a higher level of relative reliability when compared to myometer results collected in the seated calf raise machine (Table 2).

In terms of absolute reliability, results were questionable, with CV values ranging from 12.88% to 35.23% (Table 1, Table 2). Myometry in the lying and standing positions displayed more precision of measurement (%SEM 3.34–7.75) when compared to myometry in the seated calf raise machine (%SEM 7.15–17.41), vertical hop test (%SEM 10.67–14.23), and free oscillation technique under both loads (%SEM 7.38–15.23). Systematic bias was not present in any of the variables measured, with the exception of 2: free oscillation technique for the right leg with a 20 kg load (p = 0.02), and myometry of LG in the seated calf raise machine (p = 0.02) (Table 1, Table 2).

Validity results are presented in Table 4. All datasets displayed normality, with the exception of myometer measurements of SOL in the lying position. Grubb's test for outliers was utilised to eliminate 2 outlying scores for that set of data, and the remaining data were normally distributed. Thus, the sample size for myometer measurements of SOL in the lying position was reduced to a sample size of 26 for unilateral performance measurements and 13 for bilateral performance measurements.

Table 4.

Pearson's correlations between measures of stiffness and selected performance variables.

Stiffness assessment method MIF RFDiso CMJRFD SJRFD EUR
Vertical hop test −0.25 −0.24 0.34 0.54* −0.31
Free oscillations, 70%MIF −0.28 0.03 0.41 0.20 −0.39
Free oscillations, 20 kg −0.06 0.03 0.22 0.29 −0.18
Myometer, lying, LG 0.16 0.40* −0.38 −0.23 −0.71*
Myometer, lying, MG 0.18 0.38* 0.13 −0.30 −0.73*
Myometer, lying, SOL 0.18 0.22 −0.19 −0.02 −0.41
Myometer, lying, ACH 0.40* 0.48* −0.35 −0.43 −0.43
Myometer, standing, LG 0.04 0.26 −0.15 −0.25 −0.81*
Myometer, standing, MG 0.15 0.17 0.42 −0.12 −0.38
Myometer, standing, SOL 0.18 0.21 −0.19 −0.31 −0.66*
Myometer, standing, ACH 0.22 0.32 −0.18 −0.41 −0.60*
Myometer, SCRM, LG −0.09 0.34 0.00 0.00 −0.60*
Myometer, SCRM, MG −0.01 −0.08 0.23 −0.14 −0.29
Myometer, SCRM, SOL −0.01 0.14 −0.19 −0.30 −0.52*
Myometer, SCRM, ACH 0.23 0.21 −0.11 −0.35 −0.53*

Abbreviations: ACH = Achilles aponeurosis; CMJRFD = countermovement jump rate of force development; EUR = eccentric utilisation ratio; LG = lateral gastrocnemius; MG = medial gastrocnemius; MIF = maximum isometric force; RFDiso = isometric rate of force development; SCRM = seated calf raise machine; SJRFD = squat jump rate of force development; SOL = soleus.

*

p < 0.05.

Data from the vertical hop test demonstrated a significant correlation with SJRFD (Table 4). Significant positive correlations were revealed between RFDiso and myometer measurements of LG, MG, and ACH, in a lying position (Table 4). Similarly, for lying, there was a significant positive correlation between MIF and the myometer measurement of ACH. Conversely, significant and large negative correlations were evident between EUR and myometer measurements of various sites and in various positions (Table 4). No significant relationship was established between the free oscillation technique and any performance measurements.

4. Discussion

The current study was designed to establish the inter-day reliability and convergent construct validity of 3 methods of assessing stiffness using an athletic cohort. It was the first tocompare the vertical hop test, free oscillation technique, and myometry, and the results will influence future research design, especially when dealing with neuromechanical assessment of the lower body.

An important result of the current study was the good relative reliability demonstrated for the vertical hop test. These results were congruent with previous reports of good relative reliability for similar methodologies.16, 39 In previous studies, a high ICC value (0.8) was reported when a unilateral vertical hop test was administered to males,39 and high to very high ICC values (0.85–0.94) were reported for females;16 however, this study conducted bilateral hopping at various frequencies. The ICC results for the vertical hop test in the current study displayed similar levels of relative reliability, ranging from moderate to high. Interestingly, the absolute reliability of the vertical hop test was questionable, with CV scores ranging from 21.51% to 21.94%. Nevertheless, the good relative reliability and lack of systematic bias suggest that the vertical hop test is a reliable measurement of stiffness.

When determining the convergent construct validity of the vertical hop test, Pearson's correlations revealed a significant positive correlation between Kvert and SJRFD. These results were hypothesised considering the previously reported relationship between lower body stiffness and concentric RFD.24 Interestingly, there was no significant correlation between Kvert and RFDiso; however, given the differences in contraction types, such a relationship may not have been warranted. Since a criterion reference measure for lower body stiffness does not exist, concurrent validity cannot be established; however, the results from the current study suggest that the vertical hop test is a reliable tool for assessing lower body stiffness. Further, positive correlations between Kvert and dynamic strength measurements suggest that it is related to the construct of stiffness.

Many key findings relating to myometry were also revealed in the current study. Stiffness results obtained from the Myoton-Pro showed excellent levels of relative reliability in all positions, particularly standing and lying. The same variables also displayed the lowest %SEM scores in the current study, demonstrating a high level of precision of measurement. Previous reports using the Myoton-Pro have shown good to very good within-day and inter-day inter-rater reliability when measuring the stiffness of the rectus femoris in a lying position,40 and good to excellent between-day and within-session reliability when measuring the stiffness of the biceps femoris and rectus femoris in a lying position.29 Similarly good reliability results have also been reported for stiffness data collected with superseded Myoton models.14, 25, 28

When assessing for convergent construct validity, the data collected using the myometer presented a number of significant correlations with the various performance parameters. Significant positive correlations were determined between myometer stiffness of LG, MG, and ACH collected in the lying position and RFDiso. This is consistent with reports of a relationship between increased rate of contraction and increased stiffness.9, 24 Interestingly, large (0.50–0.69) and very large (0.70–0.89) inverse correlations were revealed between myometer stiffness collected under all 3 conditions and EUR results. Specifically, very large inverse correlations were revealed between EUR results and myometer stiffness measurements of LG in both lying and standing positions, and MG in a lying position. Further, large inverse correlations were also observed between EUR results and ACH and SOL in the standing position. These results are consistent with previous reports where relatively compliant subjects have shown a greater pre-stretch augmentation15, 24 and hence, greater elastic energy contribution to concentric movement. Based on these results, stiffness measurements collected by a myometer under passive conditions (lying and standing) appear to be related to dynamic muscle activities. Further, it appears that stiffness measurements by way of myometry are more relevant for the gastrocnemius musculature in the lying position, and SOL and ACH in the standing position.

The validity and reliability results for the free oscillation technique at both 70%MIF and 20 kg loads were poor. This is in direct contrast to a previous report of good reliability for the free oscillation technique measured at a load relative to 75%MIF in the same position as utilised in the current study.8 This study also reported large and significant correlations between stiffness and RFDiso bilaterally, and stiffness and MIF unilaterally. Similarly, good reliability has been reported for the free oscillation technique measured at various loads in a supine maximal isometric leg press.24 Further, the same study reported a large and significant correlation when comparing stiffness to RFDiso and SJRFD. In contrast to the current study, both the previous reports involved male subjects. Significant differences in male and female stiffness levels have been suggested,28, 41, 42 conceivably due to between-gender differences in: muscle mass and cross-sectional area,43 tendon viscoelastic properties,41 the thickness, length and pennation angle of muscle fibres,41 muscle recruitment strategies,42 or leg posture during hopping.42 The between-gender difference in stiffness could account for the differing reports of validity and reliability between those with male participants, and those with females. Regardless, it appears that stiffness results obtained using the free oscillation technique under the conditions in the current study should not be considered reliable and are not related to dynamic strength measurements.

The results from the current study are limited by various assumptions that exist in the methodology and calculation of stiffness. The vertical hop test assumes that the leg works as one linear mechanical spring, and the free oscillation technique and myometry assume the region or muscle will oscillate according to the damped spring model. A further limitation of the study is the use of convergent construct validity rather than criterion-referenced validity. Future research to establish a criterion-reference measure of lower-body stiffness would certainly be warranted.

5. Conclusion

The results from the current study demonstrate that the use of either the vertical hop test or myometry will produce valid and reliable results for the assessment of stiffness. These results are favorable to researchers, as both methods are relatively simple to administer, allowing for a potentially large cohort to be tested, and are performed under low-load conditions, posing minimal risk to participants. Further, since the vertical hop test can provide a “global” measure of lower body stiffness, whereas myometry measures the stiffness of isolated muscles, it may be suggested that a combination of both methods would provide an excellent representation of the stiffness levels of the lower body.

Authors' contributions

ECP was involved in participant recruitment, data collection, data reduction, statistical analysis and manuscript editing; MLW conceived of the study, assisted with statistical analysis and manuscript editing; AJM was involved in study design and editing the manuscript. All authors have read and approved the final version of the manuscript, and agree with the order of presentation of the authors.

Competing interests

None of the authors declare competing financial interests.

Footnotes

Peer review under responsibility of Shanghai University of Sport.

References

  • 1.McMahon T.A., Cheng G.C. The mechanics of running: how does stiffness couple with speed? J Biomech. 1990;23:65–78. doi: 10.1016/0021-9290(90)90042-2. [DOI] [PubMed] [Google Scholar]
  • 2.Seyfarth A., Geyer H., Gunther M., Blickhan R. A movement criterion for running. J Biomech. 2002;35:649–655. doi: 10.1016/s0021-9290(01)00245-7. [DOI] [PubMed] [Google Scholar]
  • 3.Butler R.J., Crowell H.P., 3rd, Davis I.M. Lower extremity stiffness: implications for performance and injury. Clin Biomech (Bristol, Avon) 2003;18:511–517. doi: 10.1016/s0268-0033(03)00071-8. [DOI] [PubMed] [Google Scholar]
  • 4.Ekstrand J., Gillquist J. The avoidability of soccer injuries. Int J Sports Med. 1983;4:124–128. doi: 10.1055/s-2008-1026025. [DOI] [PubMed] [Google Scholar]
  • 5.Pruyn E.C., Watsford M.L., Murphy A.J., Pine M.J., Spurrs R.W., Cameron M.L. Relationship between leg stiffness and lower body injuries in professional Australian football. J Sports Sci. 2012;30:71–78. doi: 10.1080/02640414.2011.624540. [DOI] [PubMed] [Google Scholar]
  • 6.Watsford M.L., Murphy A.J., McLachlan K.A., Bryant A.L., Cameron M.L., Crossley K.M. A prospective study of the relationship between lower body stiffness and hamstring injury in professional Australian Rules footballers. Am J Sports Med. 2010;38:2058–2064. doi: 10.1177/0363546510370197. [DOI] [PubMed] [Google Scholar]
  • 7.Bret C., Rahmani A., Dufour A.B., Messonnier L., Lacour J.R. Leg strength and stiffness as ability factors in 100 m sprint running. J Sports Med Phys Fitness. 2002;42:274–281. [PubMed] [Google Scholar]
  • 8.Murphy A.J., Watsford M.L., Coutts A.J., Pine M.J. Reliability of a test of musculotendinous stiffness for the triceps-surae. Phys Ther Sport. 2003;4:175–181. [Google Scholar]
  • 9.Spurrs R.W., Murphy A.J., Watsford M.L. The effect of plyometric training on distance running performance. Eur J Appl Physiol. 2003;89:1–7. doi: 10.1007/s00421-002-0741-y. [DOI] [PubMed] [Google Scholar]
  • 10.Wilson G.J., Murphy A.J., Pryor J.F. Musculotendinous stiffness: its relationship to eccentric, isometric, and concentric performance. J Appl Physiol. 1994;76:2714–2719. doi: 10.1152/jappl.1994.76.6.2714. [DOI] [PubMed] [Google Scholar]
  • 11.Kubo K., Yata H., Kanehisa H., Fukunaga T. Effects of isometric squat training on the tendon stiffness and jump performance. Eur J Appl Physiol. 2006;96:305–314. doi: 10.1007/s00421-005-0087-3. [DOI] [PubMed] [Google Scholar]
  • 12.Lambertz D., Mora I., Grosset J.F., Perot C. Evaluation of musculotendinous stiffness in prepubertal children and adults, taking into account muscle activity. J Appl Physiol. 2003;95:64–72. doi: 10.1152/japplphysiol.00885.2002. [DOI] [PubMed] [Google Scholar]
  • 13.Lambertz D., Perot C., Kaspranski R., Goubel F. Effects of long-term spaceflight on mechanical properties of muscles in humans. J Appl Physiol. 2001;90:179–188. doi: 10.1152/jappl.2001.90.1.179. [DOI] [PubMed] [Google Scholar]
  • 14.Viir R., Laiho K., Kramarenko J., Mikkelsson M. Repeatability of trapezius muscle tone assessment by a myometric method. J Mech Med Biol. 2006;6:215–228. [Google Scholar]
  • 15.Wilson G.J., Wood G.A., Elliott B.C. Optimal stiffness of series elastic component in a stretch-shorten cycle activity. J Appl Physiol. 1991;70:825–833. doi: 10.1152/jappl.1991.70.2.825. [DOI] [PubMed] [Google Scholar]
  • 16.McLachlan K.A., Murphy A.J., Watsford M.L., Rees S. The interday reliability of leg and ankle musculotendinous stiffness measures. J Appl Biomech. 2006;22:296–304. doi: 10.1123/jab.22.4.296. [DOI] [PubMed] [Google Scholar]
  • 17.Brughelli M., Cronin J. A review of research on the mechanical stiffness in running and jumping: methodology and implications. Scand J Med Sci Sports. 2008;18:417–426. doi: 10.1111/j.1600-0838.2008.00769.x. [DOI] [PubMed] [Google Scholar]
  • 18.Arampatzis A., Schade F., Walsh M., Bruggemann G.P. Influence of leg stiffness and its effect on myodynamic jumping performance. J Electromyogr Kinesiol. 2001;11:355–364. doi: 10.1016/s1050-6411(01)00009-8. [DOI] [PubMed] [Google Scholar]
  • 19.Farley C.T., Blickhan R., Saito J., Taylor C.R. Hopping frequency in humans: a test of how springs set stride frequency in bouncing gaits. J Appl Physiol. 1991;71:2127–2132. doi: 10.1152/jappl.1991.71.6.2127. [DOI] [PubMed] [Google Scholar]
  • 20.Farley C.T., Morgenroth D.C. Leg stiffness primarily depends on ankle stiffness during human hopping. J Biomech. 1999;32:267–273. doi: 10.1016/s0021-9290(98)00170-5. [DOI] [PubMed] [Google Scholar]
  • 21.Watsford M.L., Murphy A.J., Spinks W.L., Walshe A.D. Creatine supplementation and its effect on musculotendinous stiffness and performance. J Strength Cond Res. 2003;17:26–33. doi: 10.1519/1533-4287(2003)017<0026:csaieo>2.0.co;2. [DOI] [PubMed] [Google Scholar]
  • 22.Cavagna G.A. Elastic bounce of the body. J Appl Physiol. 1970;29:279–282. doi: 10.1152/jappl.1970.29.3.279. [DOI] [PubMed] [Google Scholar]
  • 23.Shorten M.R. Muscle elasticity and human performance. In: Van Gheluwe B., Atha J., editors. Current research in sports biomechanics. Karger; Basel: 1987. pp. 1–18. [Google Scholar]
  • 24.Walshe A.D., Wilson G.J., Murphy A.J. The validity and reliability of a test of lower body musculotendinous stiffness. Eur J Appl Physiol Occup Physiol. 1996;73:332–339. doi: 10.1007/BF02425495. [DOI] [PubMed] [Google Scholar]
  • 25.Bizzini M., Mannion A.F. Reliability of a new, hand-held device for assessing skeletal muscle stiffness. Clin Biomech (Bristol, Avon) 2003;18:459–461. doi: 10.1016/s0268-0033(03)00042-1. [DOI] [PubMed] [Google Scholar]
  • 26.Ditroilo M., Hunter A.M., Haslam S., De Vito G. The effectiveness of two novel techniques in establishing the mechanical and contractile responses of biceps femoris. Physiol Meas. 2011;32:1315–1326. doi: 10.1088/0967-3334/32/8/020. [DOI] [PubMed] [Google Scholar]
  • 27.Chuang L.L., Wu C.Y., Lin K.C. Reliability, validity, and responsiveness of myotonometric measurement of muscle tone, elasticity, and stiffness in patients with stroke. Arch Phys Med Rehabil. 2012;93:532–540. doi: 10.1016/j.apmr.2011.09.014. [DOI] [PubMed] [Google Scholar]
  • 28.Zinder S.M., Padua D.A. Reliability, validity, and precision of a handheld myometer for assessing in vivo muscle stiffness. J Sport Rehabil. 2011;6:1–8. doi: 10.1123/jsr.2010-0051. [DOI] [PubMed] [Google Scholar]
  • 29.Mullix J., Warner M., Stokes M. Testing muscle tone and mechanical properties of rectus femoris and biceps femoris using a novel hand held MyotonPRO device: relative ratios and reliability. Work Pap Health Sci. 2013;1:1–8. [Google Scholar]
  • 30.McGuigan M.R., Doyle T.L., Newton M., Edwards D.J., Nimphius S., Newton R.U. Eccentric utilization ratio: effect of sport and phase of training. J Strength Cond Res. 2006;20:992–995. doi: 10.1519/R-19165.1. [DOI] [PubMed] [Google Scholar]
  • 31.Ferris D.P., Farley C.T. Interaction of leg stiffness and surfaces stiffness during human hopping. J Appl Physiol. 1997;82:15–22. doi: 10.1152/jappl.1997.82.1.15. [DOI] [PubMed] [Google Scholar]
  • 32.Hebert-Losier K., Eriksson A. American Society of Biomechanics. 2013. Leg stiffness from doubly integrated ground reaction forces depend on the integration constant. Omaha, NE, USA; September 4–7. [Google Scholar]
  • 33.Ditroilo M., Watsford M., De Vito G. Validity and inter-day reliability of a free-oscillation test to measure knee extensor and knee flexor musculo-articular stiffness. J Electromyogr Kinesiol. 2011;21:492–498. doi: 10.1016/j.jelekin.2010.11.004. [DOI] [PubMed] [Google Scholar]
  • 34.Rees S.S., Murphy A.J., Watsford M.L., McLachlan K.A., Coutts A.J. Effects of proprioceptive neuromuscular facilitation stretching on stiffness and force-producing characteristics of the ankle in active women. J Strength Cond Res. 2007;21:572–577. doi: 10.1519/R-20175.1. [DOI] [PubMed] [Google Scholar]
  • 35.Bruton A., Conway J.H., Holgate S.T. Reliability: what is it, and how is it measured? Physiotherapy. 2000;86:94–99. [Google Scholar]
  • 36.Abdi H. Coefficient of variation. In: Salkind N., editor. Encyclopedia of research design. Sage; Thousand Oaks, CA: 2010. [Google Scholar]
  • 37.Dumholdt E. WB Saunders Co.; Philadelphia, PA: 1993. Physical therapy research: principles and applications. [Google Scholar]
  • 38.Hopkins W.G. Spread sheets for analysis of validity and reliability. Sport Sci. 2001;19:36–42. [Google Scholar]
  • 39.Pruyn E.C., Watsford M.L., Murphy A.J., Pine M.J., Spurrs R.W., Cameron M.L. Seasonal variation of leg stiffness in professional Australian rules footballers. J Strength Cond Res. 2013;27:1775–1779. doi: 10.1519/JSC.0b013e318273690f. [DOI] [PubMed] [Google Scholar]
  • 40.Aird L., Samuel D., Stokes M. Quadriceps muscle tone, elasticity and stiffness in older males: reliability and symmetry using the MyotonPRO. Arch Gerontol Geriatr. 2012;55:e31–9. doi: 10.1016/j.archger.2012.03.005. [DOI] [PubMed] [Google Scholar]
  • 41.Blackburn J.T., Padua D.A., Weinhold P.S., Guskiewicz K.M. Comparison of triceps surae structural stiffness and material modulus across sex. Clin Biomech (Bristol, Avon) 2006;21:159–167. doi: 10.1016/j.clinbiomech.2005.08.012. [DOI] [PubMed] [Google Scholar]
  • 42.Granata K.P., Padua D.A., Wilson S.E. Gender differences in active musculoskeletal stiffness. Part II. Quantification of leg stiffness during functional hopping tasks. J Electromyogr Kinesiol. 2002;12:127–135. doi: 10.1016/s1050-6411(02)00003-2. [DOI] [PubMed] [Google Scholar]
  • 43.Blackburn J.T., Riemann B.L., Padua D.A., Guskiewicz K.M. Sex comparison of extensibility, passive, and active stiffness of the knee flexors. Clin Biomech (Bristol, Avon) 2004;19:36–43. doi: 10.1016/j.clinbiomech.2003.09.003. [DOI] [PubMed] [Google Scholar]