Commentary: Using newer technology for an unresolved clinical dilemma

Raj Anand 1,
PMCID: PMC6213682  PMID: 30355871

Migration of the orbital implant is an infrequent but difficult complication following enucleation/evisceration with orbital implant. It is more frequently associated with enucleation technique where the extraocular muscles are imbricated in front of the spherical non-integrated orbital implant.[1]

In smaller degree of migration, it is still compatible with prosthesis, however when the implant migration is of greater degree, it can cause difficulty in prosthesis retention, shallowing of fornices, lid malposition, and of course reduced motility of the prosthesis.[2] Unfortunately, the treatment options like implant exchange and dermis fat graft have their own drawbacks[3,4] like recurrence and graft necrosis.

As of now we do not have a means to ‘push’ these migrated implants back in their original intended position and maintain that pressure so that the implant does not slip back in the extraconal space. A 3-D printed Patient Specific Implant (PSI) indeed is indeed a brilliant idea that serves this purpose.[5,6] Because of the custom contouring of the PSI, its base snugly fits into the infero-temporal basin contour of the orbit. This stable implant is rock steady in there and maintains constant pressure on the re-centered implant to remain the designated orbital position. Customizing the implant also gives an opportunity to adjust the height of the implant to control the amount of displacement for the migrated implant.

The authors deserve special credit for conceptualizing a treatment modality that is beyond the four walls of clinic, involving the expertise of 3-D printing and collaborating with Ocularistry services to get PSIs. This multidisciplinary approach to solve a clinical dilemma will surely inspire rest of us to use this technology for more such situations where there is no optimal management guideline at present.

This study also highlights the fact that prevention is better than cure. Even after using the best possible resources like 3-D printing of orbit and customizing the implant, the motility of the prosthesis does not match the motility of prosthesis over an optimal implant.[6]

References

  • 1.Shome D, Honavar SG, Raizada K, Raizada D. Implant and prosthesis movement after enucleation. Ophthalmol. 2010;117:1638–44. doi: 10.1016/j.ophtha.2009.12.035. [DOI] [PubMed] [Google Scholar]
  • 2.Allen L. the argument against imbricating the rectus muscle over spherical orbital implant after enucleation. Ophthalmol. 1983;90:1116–20. doi: 10.1016/s0161-6420(83)80055-4. [DOI] [PubMed] [Google Scholar]
  • 3.Nentwich MM, Schebitz-Walter K, Hirneiss C, Hintschich C. Dermis fat grafts as primary and secondary orbital implants. Orbit. 2014;33:33–8. doi: 10.3109/01676830.2013.844172. [DOI] [PubMed] [Google Scholar]
  • 4.Sundelin KC, Dafgard Kopp EM. Complications associated with secondary orbital implantations. Acta Ophthalmol. 2015;93:679–83. doi: 10.1111/aos.12818. [DOI] [PubMed] [Google Scholar]
  • 5.Dave TV, Gaur G, Chowdary N, Joshi D. Customized 3D printing: A novel approach to migrated orbital implant. Saudi J of Ophthalmol. 2018 doi: 10.1016/j.sjopt.2018.03.003. [In press] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Dave TV, Tiple S, Vempati S, Palo M, Ali MJ, Kaliki S, et al. Low-cost three-dimensional printed orbital template-assisted patient-specific implants for the correction of spherical orbital implant migration. Indian J Ophthalmol. 2018;66:1600–7. doi: 10.4103/ijo.IJO_472_18. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Indian Journal of Ophthalmology are provided here courtesy of Wolters Kluwer -- Medknow Publications

RESOURCES