Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2018 Nov 8;8:16526. doi: 10.1038/s41598-018-34834-5

Altered Placental Chorionic Arterial Biomechanical Properties During Intrauterine Growth Restriction

Shier Nee Saw 1, Jess Jia Hwee Tay 1, Yu Wei Poh 1, Liying Yang 3, Wei Ching Tan 3, Lay Kok Tan 3, Alys Clark 4, Arijit Biswas 2, Citra Nurfarah Zaini Mattar 2, Choon Hwai Yap 1,
PMCID: PMC6224524  PMID: 30409992

Abstract

Intrauterine growth restriction (IUGR) is a pregnancy complication due to placental dysfunction that prevents the fetus from obtaining enough oxygen and nutrients, leading to serious mortality and morbidity risks. There is no treatment for IUGR despite having a prevalence of 3% in developed countries, giving rise to an urgency to improve our understanding of the disease. Applying biomechanics investigation on IUGR placental tissues can give important new insights. We performed pressure-diameter mechanical testing of placental chorionic arteries and found that in severe IUGR cases (RI > 90th centile) but not in IUGR cases (RI < 90th centile), vascular distensibility was significantly increased from normal. Constitutive modeling demonstrated that a simplified Fung-type hyperelastic model was able to describe the mechanical properties well, and histology showed that severe IUGR had the lowest collagen to elastin ratio. To demonstrate that the increased distensibility in the severe IUGR group was related to their elevated umbilical resistance and pulsatility indices, we modelled the placental circulation using a Windkessel model, and demonstrated that vascular compliance (and not just vascular resistance) directly affected blood flow pulsatility, suggesting that it is an important parameter for the disease. Our study showed that biomechanics study on placenta could extend our understanding on placenta physiology.

Introduction

Intrauterine growth restriction (IUGR) is a condition where high vascular resistance in the placenta results in insufficient oxygen and nutrients transferred to the fetus, leading to reduced fetal growth. This condition leads to 5–10 times higher mortality risks, and long-term complications such as neurodevelopment impairment, hypertension, and diabetes13, representing the second foremost cause of perinatal morbidity and mortality4. The prevalence of IUGR is approximately 3% in developed countries and can reach up to 15% in developing countries5. The most common cause of IUGR is placental insufficiency, where there is a reduction in the density and size of blood vessels6 leading to increased vascular resistance7, and thus reduced oxygen and nutrient exchange. To date, there is no proven strategy to prevent or treat IUGR8, although well-timed early delivery of the baby to avoid in utero hypoxia and malnutrition is shown to improve outcomes9. Therefore, improved knowledge of this disease is urgently needed for the development of diagnostic, management and treatment strategies.

Biomechanics analysis of placental tissues can be one new way of understanding IUGR. In the past, biomechanics studies of blood vessels have developed important knowledge on vascular growth and remodeling process in response to biomechanical force stimuli10,11, and have played important role in the development of tissue-engineered blood vessels1214. Biomechanics analysis of normal versus diseased tissues have also deepened our understanding on tissue properties changes during disease states1517 and have led to the advent of employing elastography (non-invasive measurement of tissue stiffness) as a diagnosing tool to detect diseases18,19. We have recently performed studies of mechanical properties of normal and IUGR placental tissues20,21, while others have demonstrated the use of elastography in detecting placental diseases22,23. Furthermore, 1D biomechanics modeling of vascular network flows has enabled a better understanding of transport phenomenon and temporal variability of flow24,25. In the current study, we applied these biomechanical analyses to placental chorionic arteries, based on a belief that they can generate much more new insights on IUGR disease.

Blood flowing into the placenta via the umbilical artery is pulsatile, and its pulsatility can be quantified by Doppler indices, such as resistance index (RI) and pulsatility index (PI). These Doppler indices are often thought to directly represent the downstream placental vascular resistance and elevate when placental resistance increases26,27 and that increased placental resistance generally occurs with a substantial reduction of vascular size and density28. As such, umbilical Doppler indices are routinely used for risk stratification, surveillance, and obstetric management once an IUGR fetus is identified by ultrasound biometry measurements. This was supported by observations that absent or reversed end-diastolic flow in the umbilical arteries were mostly found in very sick IUGR cases29,30. However, recent PORTO multicenter study reported that only 46% of IUGR cases demonstrated significantly enhanced PI (>90th centile)31, implying that the RI and PI to be unreliable in representing placental vascular resistance. It might be the case that other factor, such as vascular compliance/distensibility, played a role in affecting the blood pulsatility, as proposed by previous in vitro experiments32.

Further, histological results had shown that IUGR placenta exhibited reduced elastin tissues fibers33, and direct mechanical testing of placenta showed that stiffness of placenta was different between normal and IUGR20. Thus, it is likely that the compliance of placental blood vessels could also have altered during disease and that is only in some disease cases where these mechanical properties changes were significant enough to influence the RI and PI values. Unfortunately, to date, there has been no study on the vascular mechanics or compliance of placental arteries either in normal or in IUGR pregnancies to test these hypotheses.

In this study, we have also performed numerical simulation of placental blood flow to supplement our experimental results. The two-element Windkessel mathematical model has been widely used for accurate simulation of vascular pressure and blood flow within vessels based on the interaction between stroke volume and arterial compliance24,34. This model has been applied to the pulmonary vascular bed and placenta27,35 and is useful to understand the effect of vascular resistance and compliance on blood flow, especially in diseased state, in which alterations in vascular resistance and compliance are anticipated34,36. We adopted this model in our study to investigate the relationship between the flow pulsatility and vascular compliance and resistance using clinically measured umbilical Doppler waveforms.

The overall objective of this study is to characterize the biomechanical, anatomical and hemodynamic properties of placental chorionic vessels in normal and IUGR placentae using a host of biomechanical techniques, including mechanical testing, constitutive modeling, 1D flow modeling, and corrosion casting. Substantial focus was placed on detecting changes to vascular distensibility during disease, and the role it played in affecting flow patterns and Doppler indices.

Methods

All placental tissues were obtained from women who delivered at National University Hospital and Singapore General Hospital, Singapore, in accordance with approved guidelines at the hospital. All human sample testing protocols were approved by the Singapore National Healthcare Group Domain Specific Review Boards and SingHealth Centralised Institutional Review Board, and informed consent was obtained from all participants. Following delivery, placentae were immediately placed in Phosphate Buffered Saline (PBS) and were kept in the refrigerator when not being handled. All experiments were conducted within three days after delivery. According to a previous study, properties of extracted arteries would remain unchanged in three days37.

Placental Chorionic Arteries Experiment

Anthropometric Analysis

To study the placental chorionic vascular patterns and anatomical characteristics, we performed vascular corrosion casting on 10 normal and 4 IUGR post-delivered placentae. IUGR was defined as antenatal estimated fetal weight (EFW) measured via ultrasound fell below the 10th centile, further serial monitoring did not show improvement or showed worsening EFW. Among these IUGR cases, none had umbilical arterial RI or PI above the 90th centile. Vascular corrosion casting was performed using similar protocols adopted in the past studies38,39. Dried placental vascular cast obtained after corrosion casting procedure was scanned with Siemens Dual Source Definition FLASH 256 computed-tomography (CT) scanner with the X-ray tube set at 120 kV, 40 mA, convolution kernel at J35, slice thickness of 0.5 mm, and pixel spacing of 0.2–0.4 mm. 3D segmentation of vascular cast was performed using an open source program, Vascular Modelling Toolkit (VMTK)40, which could also provide the cross-sectional areas and centerline coordinates of vessels. Placental chorionic vessels anthropometric parameters, such as vascular radius, branching angle and branching ratio were computed. The details of vascular corrosion casting procedures and equations used to compute anthropometric parameters can be found in the Supplementary Document.

Pressure-Diameter Mechanical Testing

To study the mechanical properties of placental chorionic arteries, we collected additional 6 normal and 10 IUGR placentae. Among the 10 IUGR placentae, 4 of them had abnormal umbilical arterial blood flow (RI/PI > 90th centile). As such, we divided the IUGR into two groups, which were IUGR (low EFW, normal RI/PI with values <90th centile) and severe IUGR (low EFW, high RI/PI with values >90th centile).

Mechanical testing of placental chorionic arteries was performed using a custom experiment setup as shown in Fig. 1. Details of ways in extracting the placenta arteries and pressure diameter experiment can be found in the Supplementary Document. In brief, 18 normal, 17 IUGR and 13 severe IUGR placental chorionic arteries from 6 normal and 6 IUGR and 4 severe IUGR placentae were extracted and tested. The breakdown of the vessels for each placenta: 3 vessels from 6 normal placentae each, 3 vessels from 6 IUGR placenta each, however, one IUGR placenta had only 2 vessels tested because one vessel leaked during the experiment, thus it was eliminated from the analysis, resulting in only 17 vessels. As for severe IUGR, the first 3 placentae had 3 vessels extracted and tested and the last placenta had 4 vessels tested, resulting in 13 vessels. The extracted vessel had a length of 20 mm. The vessels mostly retracted to around 18 mm after extraction and were stretched back to its original length of 20 mm on the testing rig to mimic in vivo conditions, giving an initial axial stretch of 1.1. With the three-way valve at the rightmost point closed, PBS fluid was injected into the vessels with a constant rate of 90 μl/min until it reached 40 mmHg. Thereafter, the three-way valve was opened to release the luminal pressure back to atmospheric pressure. This process of pressurization and de-pressurization was repeated for eight cycles - the first five cycles were used for pre-conditioning and the last three cycles were used for analysis. The vessel was imaged using a CMOS camera (XCAM1080PHA, Touptek) and the diameter changed of the vessel was tracked over time with a custom written MATLAB code.

Figure 1.

Figure 1

Experiment setup for mechanical testing of placental chorionic arteries. PBS solution was injected slowly into the vessels until pressure reached 40 mmHg. Diameter and pressure changed during pressurization were recorded for analysis.

The distensibility of the artery at specific luminal pressure was computed using Equation 1.

Distensibility(mmHg1)=dλdP 1

where λ is the circumferential stretch (ratio of final diameter to initial diameter) and P is the vascular luminal pressure.

After the testing, placental chorionic arteries were processed for Verhoeff-van Gieson (VVG) stain to evaluate their elastin and collagen contents. For each stained slide, three images were taken, and the results for these triplicates were averaged before being reported. From the microscopic images of histology slides, ImageJ was used to measure the relative abundance of collagen and elastin by computing the number of pixels stained in pink/purple (collagen) and in black (elastin).

Constitutive Modelling of Chorionic Vascular Mechanical Properties

To obtain an accurate description of the mechanical properties, the stress-free state of the arteries must be considered41,42. Short ring segment of the placental chorionic artery was extracted. Thickness and diameter of the ring vessel were measured. Then, a radial cut was imposed on the ring vessel, resulting in an open C sector due to the release of pre-stress. After the radial cut, the vessel was incubated for four hours at 37 °C to allow the vessels achieved their stress-free configuration fully. ImageJ was used to measure the opening angle (Figure S1 in Supplementary Document). The opening angle referred to the angle between the two lines that connect from the center of the inner sector to the two ends of the inner sector.

The placental chorionic artery was modelled as incompressible, orthotropic and homogeneous thick wall cylindrical tube. The vascular mechanics of placental chorionic arteries were characterized using the pseudo-strain energy function (Equation 2)42, named as Fung model. We incorporated residual stress in our model, assumed negligible cross stretch (b4 = b5 = b6 = 0) and similar stiffness in all three direction (b1 = b2 = b3). Detailed analytical framework can be found in the Supplementary Document.

W(E)=c2(eb1Eθ2+b1Ez2+b1Er21) 2

where c and b1 are the material parameters, E is the Green Strain and the subscripts of E refer to the three orthogonal axes.

The material parameters were obtained by performing curve-fitting using the built-in Nelder-Mead algorithm in MATLAB. The goodness-of-fit was evaluated by the coefficient of determination, R2 value.

Statistical Analysis

Given the repeated measurements within a placenta, a regression model was used to fit our results using generalized estimating equation (GEE) method in R, using geepack package43. The model was fitted with the individual specimens grouped according to placenta and then fetus status (Normal/IUGR/Severe IUGR). The used of GEE method accounts for both repeated measurements and different sample sizes within each placenta44 and such method had been used in others studies with similar situation45,46.

To compare the difference in parameters between normal and diseased groups, a full model was compared with a restricted model where the explanatory variable (fetus status) was removed. If P-value of the fetus status’ coefficient was less than 0.05, it suggested that fetus status played a significant effect in affecting the response variables. To do this, anova method in geepack package was used. When comparing the difference in parameters among the three groups – normal, IUGR and severe IUGR, similar procedure was done. If the fetus status played a significant role in affecting the response variable, post hoc test was carried out to confirm where the differences occurred between groups by testing the difference in the regression coefficients using contrast method. Bonferroni adjusted p-value, which counteracted the problem of multiple comparisons, were reported. The data was said to be significantly different if P < 0.05.

1D Modeling of Blood Flow in Umbilical-Placenta Vasculature

A network of two-element Windkessel models (Fig. 2) was adopted to model the blood flow in the placental vasculature and to investigate the effect of placental vascular resistance and compliance on umbilical arterial flow parameters such as mean flow rate, RI, PI and peak backflow rate. Each vessel consisted of one resistor and one capacitor, which represented the vascular resistance and compliance respectively. The model consisted of 1 generation of umbilical artery, 10 generations of placental arteries, 1 generation of microvilli, 10 generations of placental veins and 1 generation of umbilical vein47. The details of equations and placental vasculature measurements used in the model can be found in Supplementary Documents.

Figure 2.

Figure 2

(a) Schematic of the Windkessel modeling. The umbilical-placenta circulation is modeled as a series of two-element Windkessel models. Pi – pressure at ith generation vessel; QRi – Flow through the ith resistance; QCi – rate of fluid going into compliance storage at the ith generation vessel. (b,c) Clinical pulse wave Doppler velocity of (b) normal and (c) IUGR umbilical artery, which were used in the Windkessel modeling.

Umbilical arterial pulse pressure range was set at 50/25 mmHg (systolic/diastolic) in normal48 and 80/25 mmHg in IUGR49, while umbilical venous pressure was prescribed as a time-independent constant at 5.3 mmHg in normal and IUGR cases50. The pressure versus time waveform shape was set to be similar as the velocity versus time waveform plot, obtained from clinical pulse wave Doppler measurements, one from normal and one from IUGR with RI > 90th centile (Fig. 2b,c).

The model was first adjusted by varying the umbilical-placental resistance and compliance such that the calculated output flow rates matched the sonographically recorded flow rates. After the fitting, the umbilical-placental resistance and compliance for normal and IUGR can be obtained. Subsequently, using the normal fetus’s condition as the baseline, a parametric test was conducted by applying one single multiplier to the placental resistance and compliance to observe their effects on the flow parameters. The flow rates in the umbilical-placental circulation were computed using the built-in Ordinary Differential Equation (ODE) solver in MATLAB® (Mathworks Inc., Natick, USA).

Results

Patients’ characteristics recruited in this study are tabulated in Table S2 in the Supplementary Document. IUGR and severe IUGR babies were significantly lighter than normal babies at birth (P = 0.00027). No significant difference was observed in RI and PI between the normal and IUGR babies.

Placental Chorionic Arteries Experiment

Anthropometric Analysis

Figure 3 shows the geometrical measurements of the placental vasculature at different vascular generations. 1st generation of vessels referred to the vessels after branching from umbilical vessels, similar annotation as Fig. 2a, defined as the number of times vascular branching occurred before blood from the umbilical artery reached a particular vessel. Results showed that our geometrical measurements in normal placentae were in qualitative agreement with previous study39. Further, vascular sizes of the IUGR placental veins were substantially smaller than those in the normal placenta at most of the vascular generations investigated (P < 0.05). As for placental arteries, IUGR arteries generally had smaller vascular size but the difference was only significant at the 4th generation and weakly significant at the 3rd generation. Arterial and venous branching angles and daughter-to-mother vascular radius branching ratio, however, were generally very similar across the various vascular generations.

Figure 3.

Figure 3

(a) Placental vascular radius, (b) branching angle and (c) branching ratio (daughter vessel radius/mother vessel radius) computed from 10 normal and 4 IUGR placentae. Data presented are mean and standard errors of measurements. Vessels at 1st generation refer to vessels after branching from umbilical vessels.

Mechanical Properties of Placental Chorionic Arteries

The mean pressure-circumferential stretch curves of the placental chorionic artery for normal, IUGR (RI/PI < 90th centile) and severe IUGR (RI/PI >90th centile) are plotted in Fig. 4a. Normal and IUGR placental chorionic arteries had pressure-stretch curves with similar shapes but the IUGR curve was shifted to the left. As for severe IUGR, the arterial pressure-stretch curve had a gentler gradient than the other groups. The reciprocal of the gradient of the pressure-stretch curve at specific luminal pressure represented the arterial distensibility at that particular pressure. Figure 4b illustrates the distensibility of the placental chorionic arteries at different luminal pressures. Results demonstrated that the distensibility of the severe IUGR artery was significantly higher than the normal and IUGR arteries at all luminal pressures, except at 10 mmHg when compared with the normal artery.

Figure 4.

Figure 4

(a) The average mechanical response curves from mechanical testing. The three curves represent the data averaged from 18 normal, 17 IUGR and 13 severe IUGR placental chorionic arteries respectively. (b) Distensibility of placental chorionic arteries, computed from reciprocal of the pressure-stretch gradient, at different luminal pressures for normal, IUGR and severe IUGR groups. Data presented are mean and standard error.

Vascular geometric analysis showed that no significant difference among the three groups in opening angle (Normal: 91.48° ± SD32.61°; IUGR: 106.45° ± SD 40.27°; Severe IUGR: 96.88° ± SD 36.43°, P = 0.49) and thickness/diameter ratio (Normal: 0.586 ± SD 0.131; IUGR: 0.616 ± SD 0.227; Severe IUGR: 0.654 ± SD 0.165, P = 0.75). It is noteworthy that our opening angle measurements for the normal placental chorionic arteries had similar magnitudes as those on carotid arteries in other studies41,51.

Figure 5 shows the collagen to elastin ratio and representative VVG stain images for each group. From the images, we could qualitatively observe that elastin (stained in black) was most abundant in severe IUGR arteries as compared to normal and IUGR arteries. After image analysis, severe IUGR group was found to have the lowest collagen to elastin ratio (C/E = 4.00 ± SD 1.61), followed by normal (C/E = 6.33 ± SD 3.18) and IUGR (C/E = 11.17 ± SD 4.49). The reduction of collagen to elastin ratio in severe IUGR arteries might explain the increased arterial distensibility, as shown in Fig. 4. Regression analysis corroborated with this notion as we observed statistically significant correlations between elastin quantity and distensibility (Fig. 5c). However, no significant correlation was observed between collagen quantity and maximum stretch (Fig. 5d).

Figure 5.

Figure 5

(a) Box plot showing individual collagen to elastin ratio and the mean in normal, IUGR and severe IUGR placental chorionic arteries. (b) Representative Verhoeff-van Gieson stain images for normal, IUGR and severe IUGR. Collagen was stained pink/purple while elastin was stained black, as indicated by red arrows. (c,d) Regression analysis between (c) area fraction of elastin and distensibility at 20 mmHg and (d) area fraction of collagen and maximum stretch obtained from the pressure-stretch curve. P indicates the significance of the regression line coefficient using the GEE method.

The Fung hyperelastic mechanical model was able to fit the experimental datasets very well, with R2 value ≈ 1. The material parameters obtained from the model are summarized in Table 1. Severe IUGR showed significantly larger parameter c (P = 0.0293) and smaller parameter b1 (P = 0.0271) as compared to IUGR.

Table 1.

Material parameters determined from normal, IUGR and severe IUGR placental chorionic arteries using Fung model.

Normal (n = 18) IUGR (n = 17) Severe IUGR (n = 13)
c 125.82 ± 41.58 99.91 ± 39.08 345.65 ± 100.83 *
b 1 20.63 ± 4.57 26.83 ± 7.52 8.56 ± 1.36
R2 0.9990 ± 0.0010 0.9988 ± 0.0018 0.9885 ± 0.0019

Values indicated are mean and standard errors. *P = 0.0293 vs IUGR, P = 0.0271 vs IUGR. R2 refers to the coefficient of determination.

1D Modeling of Blood Flow in Umbilical-Placenta Vasculature

Figure 6a shows that the umbilical arterial blood flow waveforms from the Windkessel model could be tuned to match the clinical ultrasound measurements well. Subsequently, the vascular resistance and compliance were arbitrarily set at various values within a bounded range and the simulation was re-run to understand their effects on umbilical flow characteristics, and results are shown in Fig. 6b. We observed that mean flow rate had an inverse relationship with resistance but did not change with compliance, but RI and PI increased non-linearly with increasing resistance or compliance. RI and PI were shown to be dependent on both resistance and compliance, indicating that resistance alone could not uniquely represent them. The same RI and PI read-outs, as represented by the same color on the contour surface plots, could be obtained with different placental resistance values via adjusting the placental compliance value. This suggested that the prevailing assumption that these Doppler indices represent directly the downstream placental vascular resistance was likely to be erroneous. The peak backflow rate, which was the highest amount of volumetric flow rate in the retrograde direction that occurred usually at the end-diastolic time point, was non-zero only when resistance and compliance were sufficiently high. In the modelling of normal (black asterisk) and IUGR (red asterisk) pregnancies, the overall umbilical-placental vascular resistance and compliance had to be higher in IUGR to achieve a good fit between modelled and measured flow waveforms. This suggested that the increased RI and PI were partially due to increased vascular compliance.

Figure 6.

Figure 6

1D Modeling Results. (a) Clinically measured and modelled umbilical arterial blood flow waveforms showed a good fit in both normal and IUGR after tuning the umbilical-placental compliance and resistance in the Windkessel model. Their umbilical-placental resistance, compliance and other flow parameters were plotted as black (Normal) and red (IUGR) asterisks in (b). (b) Effect of umbilical-placental resistance and compliance on (i) mean flow rate, (ii) PI, (iii) RI, and (iv) peak backflow rate.

Discussion

The placenta is an important organ that supports the fetus growth throughout the pregnancy, and placenta diseases can be devastating to both fetal and mother’s health, but our knowledge of placenta physiology remains very limited. From the literature, it is apparent that tissue biomechanical characteristics and physiology has an intricate cause and effect relationship. Numerous literatures reported different pathological conditions such as diabetes52, hypertension53,54, smoking55 and obesity56 resulted in altered arterial mechanical properties. On the other hand, biomechanical forces and tissue stiffness are known to influence pathogenesis and disease progression. For example, low and oscillatory fluid mechanical shear stresses were believed to cause atherosclerosis57, and biomechanical forces in tumor were believed to influence tumor growth58. For this reason, we advocate studies of the placenta and its diseases from a biomechanics point of view.

To date, there is little information on the mechanical properties of human placental chorionic arteries in normal or IUGR pregnancies. This motivated our study, and our results revealed an interesting finding that the severe IUGR placental chorionic arteries exhibited significantly higher vascular distensibility, which was likely a result of microstructural changes to the blood vessels’ walls, and which would likely contribute to the increased umbilical Doppler indices.

From our mechanical testing results, we noted that the placental chorionic arteries from all three groups exhibited similar typical mechanical testing pressure-stretch curves with a low stiffness at a low stretch and a high stiffness at a high stretch. However, the severe IUGR artery had significantly higher distensibility at pressures between 20 mmHg to 35 mmHg, suggesting that at these physiological pressures, the vessel would undergo higher periodic stretch and luminal size changes if exposed to the same pulse pressure.

We believe that the observation of increased vascular compliance in severe IUGR vessels is an important one because umbilical flow Doppler indices, RI and PI, are used routinely in detecting IUGR. Increased umbilical flow Doppler indices in diseased cases are often thought to be due to the increased vascular resistance of blood vessels in the placenta and hence these indices are always used as direct indicators of placental vascular resistance59,60. However, our mechanical testing results showed that chorionic vessels from the severe IUGR cohort, with RI or PI above the 90th centile, had higher compliance than normal and IUGR (RI/PI < 90th centile) vessels. Our mathematical model corroborated with this finding, demonstrating that, on top of vascular resistance, vascular compliance also affected the RI and PI values, and that increased compliance was necessary to match the modelled and clinically measured umbilical flow waveforms in IUGR case. Further, reversed flow would not occur if the vessel had low compliance. This suggested that high RI, PI and/or reversed end-diastolic blood flow observed in IUGR umbilical flow was at least partially due to compliance changed, in addition to resistance changed. To date, however, evaluation of vascular resistance has dominated the literature on IUGR vasculature and hemodynamics6164, and little attention has been paid to arterial compliance.

There are several factors to consider why severe IUGR vessels become more distensible. Previous studies have found that hypoxic conditions can increase the distensibility of the uterine arteries65. This corroborates with our finding that the severe IUGR placental chorionic arteries have generally increased distensibility, raising the possibility that in severe IUGR cases, due to insufficient oxygen transfer from the mother to the fetus, placental vessels experience low oxygen environment and develop increased distensibility. The fact that the placental chorionic arteries are among the arteries with the lowest oxygen content in the fetal circulation further support this hypothesis.

Previous study showed that IUGR (with high umbilical RI) umbilical artery exhibited a reduction of vascular compliance66, which stood in contrast to our observation that the arterial distensibility/compliance increased in severe IUGR group. One possible explanation for this is that this increased vascular stiffness/decreased vascular compliance could be a response to the elevated systemic pressure that is experienced by IUGR fetuses67 and that the umbilical arteries are more susceptible to pressure changes caused by systemic pressure elevations since they are closer to the heart than the placental arteries. Other studies have also reported an increase in vascular stiffness (or decreased of vascular compliance) in carotid and umbilical arteries in IUGR rats and ewes6870. However, it was not known whether the IUGR fetus in these studies had normal or abnormal umbilical arterial blood flow, and thus comparison with our results could not be made.

From the mechanical testing and constitutive modeling results, there were clear differences between the two groups of severe IUGR and IUGR. As such, the changes from the group of normal to IUGR cannot be extrapolated to severe IUGR. Further, Fig. 5a showed that the IUGR vessels exhibited greater collagen to elastin ratio than the normal vessels, but the severe IUGR vessels exhibited lower collagen to elastin ratio than the normal vessels. Together, these results raised the possibility that the IUGR and severe IUGR groups could be different disease manifestations, a notion that warrants future investigations, as it might have clinical implications.

Apart from these differences, other investigations did not show a difference between normal and IUGR groups. Our vascular geometrical analysis showed that the vascular branching patterns, opening angle and thickness/diameter ratio were very similar in both normal and IUGR placentae at a macro level, suggesting that the diseased placenta retained some features from the normal placenta and might have similar vascular growth and remodeling responses and transport mechanisms as the normal placenta. This could be corroborated by one of our previous studies showing that the umbilical vascular flow mechanical force environments between normal and IUGR were very similar71,72.

There were a few limitations in this study. Firstly, severe IUGR placentae were not collected for anthropometric analysis. This was because there were few severe IUGR cases and sample collection was difficult. However, we believe that the vascular size in severe IUGR placenta will be significantly smaller as it represents the more severe disease case. Secondly, the pressure-diameter mechanical testing experiments were conducted at room temperature instead of body temperature but previous studies had shown that the effect of temperature on the arterial mechanical behavior was small73.

In conclusion, we had adopted various biomechanical analyses to study the IUGR placenta and revealed essential differences between normal and IUGR placental vessels. Our results showed that severe IUGR arteries had greater vascular distensibility as compared to normal and IUGR arteries, which could explain the clinical observation of abnormally high blood flow pulsatility in these severe IUGR umbilical cords. Mathematical modelling of blood flow in the umbilical-placenta vascular network corroborated these results and demonstrated that vascular distensibility to be an important determinant of blood flow pulsatility. The alteration of vascular mechanical properties in arteries in diseased placenta could be due to the observed changes in their extracellular matrix. The insights provided by this study demonstrated that biomechanical analysis could be a relevant and useful technique in exploring the placenta physiology.

Electronic supplementary material

Supplementary Information (247.9KB, docx)

Acknowledgements

This research was supported by the National University of Singapore Young Investigator Award, entitled “Fluid Mechanics and Mechanobiology of the Congenital Cardiac Outflow Tract Malformations” (PI: Yap). We would like to express our gratitude to Cecille Arquillo Laureano, Cynthia Pamela Zapata Tagarino, Maylene Zipagan and other staff members from Obstetrics & Gynecology Department at National University Hospital and Singapore General Hospital for their assistance with patient eligibility and tissue procurement. We would like to express our very great appreciation to Dr. Vik Gopal from Data Analytics Consulting Centre, Department of Statistics and Applied Probability for his technical advice on GEE methods.

Author Contributions

A.C., L.Y., W.C.T., C.N.Z.M., L.K.T. and A.B. provided comments and inputs for designing the experiment. S.N.S., J.J.H.T., Y.W.P. and C.H.Y. conceived and planned the experiments. S.N.S., J.J.H.T. and Y.W.P. carried out the corrosion casting experiment. S.N.S. carried out the mechanical testing experiments. S.N.S. and J.J.H.T. performed the analysis. S.N.S., J.J.H.T. and C.H.Y. contributed to interpretation of the results. S.N.S. lead in writing manuscript. All authors discussed the results, provided critical feedbacks and reviewed the manuscript. C.H.Y. supervised the project.

Data Availability

The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.

Competing Interests

The authors declare no competing interests.

Footnotes

Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Supplementary information accompanies this paper at 10.1038/s41598-018-34834-5.

References

  • 1.Barker DJ. Fetal origins of cardiovascular disease. Annals of medicine. 1999;31(Suppl 1):3–6. doi: 10.1080/07853890.1999.11904392. [DOI] [PubMed] [Google Scholar]
  • 2.Seckl Jonathan R. Physiologic Programming of the Fetus. Clinics in Perinatology. 1998;25(4):939–962. doi: 10.1016/S0095-5108(18)30091-5. [DOI] [PubMed] [Google Scholar]
  • 3.Hill DJ. Fetal programming of the pancreatic β cells and the implications for postnatal diabetes. Seminars in Neonatology. 1999;4:99–113. doi: 10.1016/S1084-2756(99)80012-8. [DOI] [Google Scholar]
  • 4.Lyons, P. In Obstetrics in Family Medicine 45–53 (Springer, 2015).
  • 5.Barut F, et al. Intrauterine growth restriction and placental angiogenesis. Diagnostic pathology. 2010;5:24. doi: 10.1186/1746-1596-5-24. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Mayhew TM, et al. Stereological Investigation of Placental Morphology in Pregnancies Complicated by Pre-eclampsia with and without Intrauterine Growth Restriction. Placenta. 2003;24:219–226. doi: 10.1053/plac.2002.0900. [DOI] [PubMed] [Google Scholar]
  • 7.Trudinger BJ, et al. Umbilical artery flow velocity waveforms and placental resistance: The effects of embolization of the umbilical circulation. American Journal of Obstetrics and Gynecology. 1987;157:1443–1448. doi: 10.1016/S0002-9378(87)80241-7. [DOI] [PubMed] [Google Scholar]
  • 8.American College of, O. & Gynecologists. ACOG Practice bulletin no. 134: fetal growth restriction. Obstetrics and gynecology121, 1122-1133, 10.1097/01.AOG.0000429658.85846.f9 (2013). [DOI] [PubMed]
  • 9.Lindqvist PG, Molin J. Does antenatal identification of small-for-gestational age fetuses significantly improve their outcome? Ultrasound Obst Gyn. 2005;25:258–264. doi: 10.1002/Uog.1806. [DOI] [PubMed] [Google Scholar]
  • 10.Taber LA. Biomechanics of Growth, Remodeling, and Morphogenesis. Applied Mechanics Reviews. 1995;48:487–545. doi: 10.1115/1.3005109. [DOI] [Google Scholar]
  • 11.Hoefer IE, den Adel B, Daemen MJAP. Biomechanical factors as triggers of vascular growth. Cardiovascular Research. 2013;99:276–283. doi: 10.1093/cvr/cvt089. [DOI] [PubMed] [Google Scholar]
  • 12.Seliktar D, Nerem RM, Galis ZS. Mechanical Strain-Stimulated Remodeling of Tissue-Engineered Blood Vessel Constructs. Tissue Engineering. 2003;9:657–666. doi: 10.1089/107632703768247359. [DOI] [PubMed] [Google Scholar]
  • 13.Nerem RM. Tissue engineering a blood vessel substitute: the role of biomechanics. Yonsei Medical Journal. 2000;41:735–739. doi: 10.3349/ymj.2000.41.6.735. [DOI] [PubMed] [Google Scholar]
  • 14.Wanjare M, Agarwal N, Gerecht S. Biomechanical strain induces elastin and collagen production in human pluripotent stem cell-derived vascular smooth muscle cells. American Journal of Physiology-Cell Physiology. 2015;309:C271–C281. doi: 10.1152/ajpcell.00366.2014. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I. Assessment of the Biomechanical Properties of the Cornea with the Ocular Response Analyzer in Normal and Keratoconic Eyes. Investigative Ophthalmology & Visual Science. 2007;48:3026–3031. doi: 10.1167/iovs.04-0694. [DOI] [PubMed] [Google Scholar]
  • 16.Goh J. T. W. Biomechanical Properties of Prolapsed Vaginal Tissue in Pre- and Postmenopausal Women. International Urogynecology Journal. 2002;13(2):76–79. doi: 10.1007/s001920200019. [DOI] [PubMed] [Google Scholar]
  • 17.Krouskop TA, Wheeler TM, Kallel F, Garra BS, Hall T. Elastic moduli of breast and prostate tissues under compression. Ultrasonic imaging. 1998;20:260–274. doi: 10.1177/016173469802000403. [DOI] [PubMed] [Google Scholar]
  • 18.Plewes DB, Bishop J, Samani A, Sciarretta J. Visualization and quantification of breast cancer biomechanical properties with magnetic resonance elastography. Physics in Medicine & Biology. 2000;45:1591. doi: 10.1088/0031-9155/45/6/314. [DOI] [PubMed] [Google Scholar]
  • 19.Tsochatzis E, et al. Elastography for the diagnosis of severity of fibrosis in chronic liver disease: a meta-analysis of diagnostic accuracy. Journal of hepatology. 2011;54:650–659. doi: 10.1016/j.jhep.2010.07.033. [DOI] [PubMed] [Google Scholar]
  • 20.Shier Nee Saw, J. Y. R. L., et al Hyperelastic Mechanical Properties of Ex Vivo Normal and Intrauterine Growth Restricted Placenta. Annals of Biomedical Engineering (2018). [DOI] [PubMed]
  • 21.Saw, S. N. et al. Motorizing and Optimizing Ultrasound Strain Elastography for Detection of Intrauterine Growth Restriction Pregnancies. Ultrasound in medicine & biology (2018). [DOI] [PubMed]
  • 22.Durhan G, et al. Placental Elasticity and Histopathological Findings in Normal and Intra-Uterine Growth Restriction Pregnancies Assessed with Strain Elastography in Ex Vivo Placenta. Ultrasound Med Biol. 2017;43:111–118. doi: 10.1016/j.ultrasmedbio.2016.08.037. [DOI] [PubMed] [Google Scholar]
  • 23.Cimsit C, Yoldemir T, Akpinar IN. Shear wave elastography in placental dysfunction: comparison of elasticity values in normal and preeclamptic pregnancies in the second trimester. Journal of ultrasound in medicine: official journal of the American Institute of Ultrasound in Medicine. 2015;34:151–159. doi: 10.7863/ultra.34.1.151. [DOI] [PubMed] [Google Scholar]
  • 24.Westerhof N, Lankhaar J-W, Westerhof BE. The arterial Windkessel. Medical & Biological Engineering & Computing. 2009;47:131–141. doi: 10.1007/s11517-008-0359-2. [DOI] [PubMed] [Google Scholar]
  • 25.Stergiopulos N, Meister JJ, Westerhof N. Evaluation of methods for estimation of total arterial compliance. American Journal of Physiology-Heart and Circulatory Physiology. 1995;268:H1540–H1548. doi: 10.1152/ajpheart.1995.268.4.H1540. [DOI] [PubMed] [Google Scholar]
  • 26.Morrow RJ, Adamson SL, Bull SB, Ritchie JW. Effect of placental embolization on the umbilical arterial velocity waveform in fetal sheep. Am J Obstet Gynecol. 1989;161:1055–1060. doi: 10.1016/0002-9378(89)90783-7. [DOI] [PubMed] [Google Scholar]
  • 27.Thompson RS, Trudinger BJ. Doppler waveform pulsatility index and resistance, pressure and flow in the umbilical placental circulation: an investigation using a mathematical model. Ultrasound Med Biol. 1990;16:449–458. doi: 10.1016/0301-5629(90)90167-B. [DOI] [PubMed] [Google Scholar]
  • 28.Mitra SC, Seshan SV, Riachi LE. Placental vessel morphometry in growth retardation and increased resistance of the umbilical artery Doppler flow. Journal of Maternal-Fetal Medicine. 2000;9:282–286. doi: 10.1002/1520-6661(200009/10)9:5<282::AID-MFM5>3.0.CO;2-J. [DOI] [PubMed] [Google Scholar]
  • 29.Figueras F, Gardosi J. Intrauterine growth restriction: new concepts in antenatal surveillance, diagnosis, and management. American Journal of Obstetrics and Gynecology. 2011;204:288–300. doi: 10.1016/j.ajog.2010.08.055. [DOI] [PubMed] [Google Scholar]
  • 30.Khanduri S, Parashari UC, Bashir S, Bhadury S, Bansal A. Comparison of Diagnostic Efficacy of Umbilical Artery and Middle Cerebral Artery Waveform with Color Doppler Study for Detection of Intrauterine Growth Restriction. Journal of Obstetrics and Gynaecology of India. 2013;63:249–255. doi: 10.1007/s13224-012-0326-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Unterscheider J, et al. Optimizing the definition of intrauterine growth restriction: the multicenter prospective PORTO Study. Am J Obstet Gynecol. 2013;208(290):e291–296. doi: 10.1016/j.ajog.2013.02.007. [DOI] [PubMed] [Google Scholar]
  • 32.Bude RO, Rubin JM. Relationship between the Resistive Index and Vascular Compliance and Resistance 1. Radiology. 1999;211:411–417. doi: 10.1148/radiology.211.2.r99ma48411. [DOI] [PubMed] [Google Scholar]
  • 33.Wilhelm D, et al. Decrease of elastic tissue fibres in stem villus blood vessels of the human placenta during IUGR and IUGR with concomitant pre-eclampsia. Anatomy and embryology. 2002;205:393–400. doi: 10.1007/s00429-002-0252-y. [DOI] [PubMed] [Google Scholar]
  • 34.Saouti N, Westerhof N, Postmus PE, Vonk-Noordegraaf A. The arterial load in pulmonary hypertension. European Respiratory Review. 2010;19:197–203. doi: 10.1183/09059180.00002210. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Kleiner-Assaf A, Jaffa AJ, Elad D. Hemodynamic model for analysis of Doppler ultrasound indexes of umbilical blood flow. American Journal of Physiology-Heart and Circulatory Physiology. 1999;276:H2204–H2214. doi: 10.1152/ajpheart.1999.276.6.H2204. [DOI] [PubMed] [Google Scholar]
  • 36.Lankhaar J-W, et al. Quantification of right ventricular afterload in patients with and without pulmonary hypertension. American Journal of Physiology - Heart and Circulatory Physiology. 2006;291:H1731–H1737. doi: 10.1152/ajpheart.00336.2006. [DOI] [PubMed] [Google Scholar]
  • 37.Stemper BD, et al. Mechanics of fresh, refrigerated, and frozen arterial tissue. The Journal of surgical research. 2007;139:236–242. doi: 10.1016/j.jss.2006.09.001. [DOI] [PubMed] [Google Scholar]
  • 38.Junaid TO, Bradley RS, Lewis RM, Aplin JD, Johnstone ED. Whole organ vascular casting and microCT examination of the human placental vascular tree reveals novel alterations associated with pregnancy disease. Scientific Reports. 2017;7:4144. doi: 10.1038/s41598-017-04379-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Gordon Z, et al. Anthropometry of fetal vasculature in the chorionic plate. Journal of Anatomy. 2007;211:698–706. doi: 10.1111/j.1469-7580.2007.00819.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Antiga, L. A. D. S. VMTK-Vascular Modeling Toolkit, http://www.vmtk.org (2006).
  • 41.Wang Ruoya, Gleason Rudolph L. A Mechanical Analysis of Conduit Arteries Accounting for Longitudinal Residual Strains. Annals of Biomedical Engineering. 2010;38(4):1377–1387. doi: 10.1007/s10439-010-9916-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Chuong CJ, Fung YC. On residual stresses in arteries. Journal of biomechanical engineering. 1986;108:189–192. doi: 10.1115/1.3138600. [DOI] [PubMed] [Google Scholar]
  • 43.Halekoh U, Højsgaard S, Yan J. The R package geepack for generalized estimating equations. Journal of Statistical Software. 2006;15:1–11. doi: 10.18637/jss.v015.i02. [DOI] [Google Scholar]
  • 44.Liang K-Y, Zeger SL. Longitudinal data analysis using generalized linear models. Biometrika. 1986;73:13–22. doi: 10.1093/biomet/73.1.13. [DOI] [Google Scholar]
  • 45.Yao W, et al. Measuring the compressive viscoelastic mechanical properties of human cervical tissue using indentation. Journal of the Mechanical Behavior of Biomedical Materials. 2014;34:18–26. doi: 10.1016/j.jmbbm.2014.01.016. [DOI] [PubMed] [Google Scholar]
  • 46.Fernandez Michael, Vink Joy, Yoshida Kyoko, Wapner Ronald, Myers Kristin M. Direct Measurement of the Permeability of Human Cervical Tissue. Journal of Biomechanical Engineering. 2013;135(2):021024. doi: 10.1115/1.4023380. [DOI] [PubMed] [Google Scholar]
  • 47.Clark AR, Lin M, Tawhai M, Saghian R, James JL. Multiscale modelling of the feto-placental vasculature. Interface focus. 2015;5:20140078. doi: 10.1098/rsfs.2014.0078. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Struijk PC, et al. Blood pressure estimation in the human fetal descending aorta. Ultrasound in obstetrics & gynecology: the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2008;32:673–681. doi: 10.1002/uog.6137. [DOI] [PubMed] [Google Scholar]
  • 49.Miyashita S, et al. Measurement of internal diameter changes and pulse wave velocity in fetal descending aorta using the ultrasonic phased-tracking method in normal and growth-restricted fetuses. Ultrasound Med Biol. 2015;41:1311–1319. doi: 10.1016/j.ultrasmedbio.2014.12.008. [DOI] [PubMed] [Google Scholar]
  • 50.Weiner CP, et al. Normal values for human umbilical venous and amniotic fluid pressures and their alteration by fetal disease. American Journal of Obstetrics & Gynecology. 1989;161:714–717. doi: 10.1016/0002-9378(89)90387-6. [DOI] [PubMed] [Google Scholar]
  • 51.Liu SQ, Fung YC. Zero-Stress States of Arteries. Journal of biomechanical engineering. 1988;110:82–84. doi: 10.1115/1.3108410. [DOI] [PubMed] [Google Scholar]
  • 52.Stehouwer CDA, Henry RMA, Ferreira I. Arterial stiffness in diabetes and the metabolic syndrome: a pathway to cardiovascular disease. Diabetologia. 2008;51:527. doi: 10.1007/s00125-007-0918-3. [DOI] [PubMed] [Google Scholar]
  • 53.Blacher J, Safar ME. Large-artery stiffness, hypertension and cardiovascular risk in older patients. Nature Clinical Practice Cardiovascular Medicine. 2005;2:450. doi: 10.1038/ncpcardio0307. [DOI] [PubMed] [Google Scholar]
  • 54.Laurent S, Boutouyrie P. Recent Advances in Arterial Stiffness and Wave Reflection in Human Hypertension. Hypertension (Dallas, Tex.: 1979) 2007;49(1206):1202. doi: 10.1161/hypertensionaha.106.076166. [DOI] [PubMed] [Google Scholar]
  • 55.Mahmud A, Feely J. Effect of Smoking on Arterial Stiffness and Pulse Pressure Amplification. Hypertension: Journal of the American Heart Association. 2003;41:183–187. doi: 10.1161/01.HYP.0000047464.66901.60. [DOI] [PubMed] [Google Scholar]
  • 56.Safar ME, Czernichow S, Blacher J. Obesity, arterial stiffness, and cardiovascular risk. Journal of the American Society of Nephrology. 2006;17:S109–S111. doi: 10.1681/ASN.2005121321. [DOI] [PubMed] [Google Scholar]
  • 57.Peiffer V, Sherwin SJ, Weinberg PD. Does low and oscillatory wall shear stress correlate spatially with early atherosclerosis? A systematic review. Cardiovascular research. 2013;99:242–250. doi: 10.1093/cvr/cvt044. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Shieh AC. Biomechanical forces shape the tumor microenvironment. Ann Biomed Eng. 2011;39:1379–1389. doi: 10.1007/s10439-011-0252-2. [DOI] [PubMed] [Google Scholar]
  • 59.Lee S, Walker SP. The role of ultrasound in the diagnosis and management of the growth restricted fetus. Australasian Journal of Ultrasound in Medicine. 2010;13:31–36. doi: 10.1002/j.2205-0140.2010.tb00161.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60.Su EJ. Role of the fetoplacental endothelium in fetal growth restriction with abnormal umbilical artery Doppler velocimetry. American Journal of Obstetrics and Gynecology. 2015;213:S123–S130. doi: 10.1016/j.ajog.2015.06.038. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Cohen E, Wong FY, Horne RSC, Yiallourou SR. Intrauterine growth restriction: impact on cardiovascular development and function throughout infancy. Pediatric research. 2016;79:821. doi: 10.1038/pr.2016.24. [DOI] [PubMed] [Google Scholar]
  • 62.Harvey-Wilkes KB, Nielsen HC, D’Alton ME. Elevated endothelin levels are associated with increased placental resistance. Am J Obstet Gynecol. 1996;174:1599–1604. doi: 10.1016/S0002-9378(96)70613-0. [DOI] [PubMed] [Google Scholar]
  • 63.Giles WB, Trudinger BJ, Baird PJ. Fetal umbilical artery flow velocity waveforms and placental resistance: pathological correlation. BJOG: An International Journal of Obstetrics & Gynaecology. 1985;92:31–38. doi: 10.1111/j.1471-0528.1985.tb01045.x. [DOI] [PubMed] [Google Scholar]
  • 64.Cahill LS, et al. Feto- and utero-placental vascular adaptations to chronic maternal hypoxia in the mouse. J Physiol. 2017 doi: 10.1113/jp274845. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65.Mateev SN, Mouser R, Young DA, Mecham RP, Moore LG. Chronic hypoxia augments uterine artery distensibility and alters the circumferential wall stress-strain relationship during pregnancy. Journal of applied physiology (Bethesda, Md. 1985) 2006;100(1850):1842. doi: 10.1152/japplphysiol.00618.2005. [DOI] [PubMed] [Google Scholar]
  • 66.Burkhardt T, et al. Decreased Umbilical Artery Compliance and IGF-I Plasma Levels in Infants with Intrauterine Growth Restriction – Implications for Fetal Programming of Hypertension. Placenta. 2009;30:136–141. doi: 10.1016/j.placenta.2008.11.005. [DOI] [PubMed] [Google Scholar]
  • 67.Louey S, Cock ML, Stevenson KM, Harding R. Placental Insufficiency and Fetal Growth Restriction Lead to Postnatal Hypotension and Altered Postnatal Growth in Sheep. Pediatric research. 2000;48:808–814. doi: 10.1203/00006450-200012000-00018. [DOI] [PubMed] [Google Scholar]
  • 68.Dodson RB, et al. Increased arterial stiffness and extracellular matrix reorganization in intrauterine growth-restricted fetal sheep. Pediatric research. 2013;73:147–154. doi: 10.1038/pr.2012.156. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69.Dodson RB, Rozance PJ, Reina-Romo E, Ferguson VL, Hunter KS. Hyperelastic remodeling in the intrauterine growth restricted (IUGR) carotid artery in the near-term fetus. J Biomech. 2013;46:956–963. doi: 10.1016/j.jbiomech.2012.12.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 70.Dodson RB, et al. Intrauterine Growth Restriction Influences Vascular Remodeling and Stiffening in the Weanling Rat More than Sex or Diet. American journal of physiology. Heart and circulatory physiology, ajpheart. 2016;00610:02016. doi: 10.1152/ajpheart.00610.2016. [DOI] [PubMed] [Google Scholar]
  • 71.Saw Shier Nee, Poh Yu Wei, Chia Dawn, Biswas Arijit, Mattar Citra Nurfarah Zaini, Yap Choon Hwai. Characterization of the hemodynamic wall shear stresses in human umbilical vessels from normal and intrauterine growth restricted pregnancies. Biomechanics and Modeling in Mechanobiology. 2018;17(4):1107–1117. doi: 10.1007/s10237-018-1017-8. [DOI] [PubMed] [Google Scholar]
  • 72.Saw, S. N., Dawn, C., Biswas, A., Mattar, C. N. Z. & Yap, C. H. Characterization of the in vivo wall shear stress environment of human fetus umbilical arteries and veins. Biomechanics and Modeling in Mechanobiology, 1–15 (2016). [DOI] [PubMed]
  • 73.Atienza JM, et al. The Influence of Pressure and Temperature on the Behavior of the Human Aorta and Carotid Arteries. Revista Española de Cardiología (English Edition) 2007;60:259–267. doi: 10.1016/S1885-5857(07)60150-9. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information (247.9KB, docx)

Data Availability Statement

The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.


Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES