Prevalence of Legionella Species in Water Resources of Iran: A Systematic Review and Meta-Analysis

Azad Khaledi PhD 1,2, Afsane Bahrami PhD 3, Edris Nabizadeh MSc 4, Yousef Amini PhD 5, Davoud Esmaeili PhD 6,7,8
PMCID: PMC6230937  PMID: 30510333

Abstract

Background:

Legionella species are ubiquitous and naturally found in lakes, rivers, streams and hot springs, and other water resources. The present study aimed to investigate the prevalence of Legionella species in water resources of Iran by a systematic review and meta-analysis.

Methods:

In search of papers relevant to the prevalence of Legionella in water resources of Iran, the scientific information database in both English and Persian languages was used. The search was limited to studies between the year 2000 and end of July 2016. Each cohort and cross-sectional study that reported the contamination of water with Legionella was included in the present study. For data analysis, comprehensive meta-analysis software with Cochran’s Q and I2 tests were used. P values less than 0.05 were considered statistically significant.

Results:

The prevalence of Legionella species in water resources of Iran was 27.3% (95% CI: 25.3-29.3). The prevalence of Legionella spp. in hospital water, dental settings water, and other water resources were 28.8% (95% CI: 26.4-31.2), 23.6% (95% CI: 16.1-33.2), and 29.6% (95% CI: 25.6-33.8), respectively. The most common Legionella species was L. pneumophila with a prevalence of 60.5% (95% CI: 53.3-67.2) and the prevalence of all other species was 52.5% (95% CI: 44.7-60.2). The highest prevalence was reported in Isfahan with 55.7% (95% CI: 48.0-63.0).

Conclusion:

Based on the results, the prevalence rate of Legionella species in water resources of Iran was high and the most common Legionella species was L. pneumophila.

Keywords: Legionella, Water Resources , Iran


What’s Known

  • The most common Legionella species in the world is L. pneumophila.

What’s New

  • For the first time, it is determined that the combined prevalence of Legionella species in water resources of Iran is 27.3%.

  • The combined prevalence of Legionella spp. in hospital water, dental settings water, and other water resources are 28.8%, 23.6%, and 29.6%, respectively.

  • The most common Legionella species is L. pneumophila with 60.5% prevalence.

Introduction

Legionella spp. are ubiquitous and naturally found in lakes, rivers, streams and hot springs, swimming pools, water tanks, water piping systems, cooling towers and air conditioning systems.1 So far, 52 species of this bacterium have been detected among which Legionellapneumophila is the most important pathogenic species to humans.2 Of the 52 species and 71 serogroups of Legionella family that can contaminate water sources, at least 20 species are pathogenic to humans, especially in those individuals with underlying medical conditions such as chronic respiratory disease, immunocompromised, undergone surgery requiring general anesthesia, or undergone kidney transplantation.3 High age, gender, smoking, alcohol consumption, and underlying diseases such as chronic lung disease, heart and kidney failure, type 2 diabetes, inadequate antibiotic treatment, immunity defects, and prolonged hospitalization have been identified as being the highest risk factors for diseases associated with Legionella.4 Certain species of Legionella are associated with asymptomatic disease (Legionnaires) or disease with a mild cough, fever, and sore throat (Pontiac fever).5 The disease occurs subsequent to exposure to the aquatic environment, when the water is stagnant and warm (25-42 °C) and the bacteria are inhaled into the lungs accompanied by aerosolized droplets. The most frequent route transmission is through inhalation or microaspiration of Legionella from contaminated water sources, including hot water systems and water from cooling towers. It has also occurred through nebulizers and showers.6 Based on CDC’s estimates, hospitalization rate caused by legionellosis accounts for 8,000 to 18,000 people in the United States each year.7 Common habitats for this bacterium are hospitals that provide susceptible conditions for people to contract the disease.8 The first outbreak of the disease was reported in 1957.9 The prevalence range of legionellosis outbreaks in hospitalized patients has been reported at 0% to 47%.7 According to reports, 3% to 8% of all community-acquired pneumonias (CAP) are likely produced by Legionella spp. and 85% of those result from L. pneumophila.10Legionella nosocomial infection prevalence is often associated with the contamination of hospital water resources.11 Biofilm formation of Legionella in water piping systems will ensure the survival of this bacterium and thus it could resist the biochemical effects of chlorine and other disinfectants.12 Epidemiological data show that the epidemic with the highest numbers of Legionella occurs in water.13 The important point is that Legionella in certain circumstances includes encounters with poor diet, oxidative stress, stress of osmotic pressure, and water chlorination convert to the mode that is still viable but is not culturable.14 Water stagnation, temperatures between 25 °C to 42 °C, organic contamination, and the presence of protozoa are suitable and susceptible conditions for the growth of Legionella species in water.15 Despite many reports pertaining to Legionella and its prevalence in water resources of different countries, there are few reports about this bacterium in Iran and in fact, at present, there is no meta-analysis.16 Therefore, the present study aimed to investigate the prevalence of Legionella species in water resources of Iran by a systematic review and meta-analysis.

Materials and Methods

Search Strategies

According to the Prisma protocol (PRISMA, http://www.prisma-statement.org) for searching papers, various databases were used to select articles in both English and Persian languages. Targeted databases were PubMed, Scopus, Web of Science, Cochrane Library, ScienceDirect, MEDLINE, Google Scholar, the Iranian Scientific Information Database (www.sid.ir), Iranmedex (www.iranmedex.com), Magiran (www. magiran.com), and Irandoc (www.irandoc.ac.ir). The search was limited to studies between the year 2000 and end of July 2016. The applied keywords included Legionella and Iran in combination with words such as epidemiology, hospital water, tap water, and cooling water. Two investigators, one with a background in bacteriology and the other in epidemiology, independently searched the relevant studies.

Inclusion and Exclusion Criteria

Each cohort and cross-sectional study that reported contamination with Legionella in Iran was included in the present study. The search was restricted to environmental studies. The exclusion criteria were clinical trials, review articles, letters to the editor, congress and meeting abstracts, short communication articles, papers presented in languages other than English or Persian, animal studies, meta-analysis or systematic reviews, abstract forms of studies, case report articles, duplicate publication of the same paper, unpublished studies, confusing studies, and studies with sample size less than 20. To include all relevant and potential studies, the references of systematic reviews and meta-analysis papers were surveyed.

Data Extraction

Following a careful and detailed study of full-text articles, information such as the name of first author, study period, publication year, location of the study, sample size, sampling location, number of positive samples, diagnostic methods and the prevalence rate, number of Legionella spp., and detection methods were extracted. The information was then entered into Microsoft Excel software.

Data Synthesis and Analysis

Data analysis was performed using comprehensive meta-analysis software version 3.3.070. In case of heterogeneity, random effects model was used. To calculate the possibly of heterogeneity between studies, the Cochrane Q and I2 tests were used. The prevalence of contamination of water resources with Legionella was reported with 95% confidence intervals (CIs).

Results

Characteristics of Selected Studies

As shown in figure 1, 3,886 studies were identified by searching the English and Persian databases out of which 680 papers were excluded because of duplication and 3,203 articles were included for eligibility evaluation. Then, 380 articles were excluded due to the study design, book, congress, publication prior to the year 2000, thesis, or were in other languages. In the next step, the abstracts of 2,823 papers were screened and 2,608 papers were excluded due to subject irrelevance. Subsequently, 215 papers with full texts were evaluated out of which 189 papers were deleted owing to the incomplete report of prevalence data, confusing data, or sample size less than 20. Finally, 26 studies were included in the meta-analysis (16 studies related to hospital water, 3 studies related to dental settings water, and the remaining 7 studies were associated with other water resources). The selected studies were from different geographical regions of Iran and approximately covered the country as a whole, but mostly focused on the central region, especially in Tehran (n=8) followed by Isfahan (n=5). The largest sample size belonged to the study dated 2015 by Yazdanbakhsh et al.

Figure1.

Figure1

Flow diagram of the study process according to the inclusion and exclusion criteria.

Phenotypic and molecular methods have been used for the detection and identification of Legionella species. The detection of phenotypic methods included morphology, culture on BCYE-a medium and smear microscopy as well as molecular techniques and biochemical tests such as PCR, nested PCR, real-time PCR, DFA, ELISA, and latex agglutination. Six studies used both phenotypic/biochemical tests and molecular methods for detection and identification and 11 studies only applied molecular techniques (table 1). Based on the selected studies (figure 2), the prevalence of Legionella species in water resources varied from 0% (95% CI: 0.0-1.4) to 70% (95% CI: 57.3-80.2).

Table 1.

Characteristics of the included studies for meta-analysis

Study Year of study Publication (year) Location Sample size Number of Legionella spp., Detection methods
Hosseini Doust17 - 2003 Tehran 32 6 PCR
Hosseini Doust et al.18 2006 2008 Tehran 132 30 Morphology, PCR
Mohabati Mobarez19 - 2007 Tehran 110 29 Morphology, PCR
Eslami20 2011 2012 Tehran 32 11 Morphology, PCR
Rafiee21 2011-2012 2014 Tehran 45 13 Morphology
Esmaeili22 - 2008 Tehran 113 30 Real-time PCR
Yaslianifard23 2010-2011 2012 Tehran 52 5 Morphology
Mirmohamadlou24 2013-2014 2016 Tehran 150 56 Morphology, PCR
Baghal Asghari25 - 2012 Isfahan 33 23 Nested PCR
Baghal Asghari et al.26 - 2012 Isfahan 60 42 Morphology, Nested PCR
Baghal Asghari and Nikaeen27 - 2013 Isfahan 44 29 Morphology, DFA
Movahedian Attar28 2003 2004 Isfahan 30 11 PCR
Ghalyani29 - 2015 Isfahan 50 5 Morphology, Latex agglutination
Motaharrynia30 - 2010 Zanjan 120 25 Morphology, PCR
Ghotaslou31 - 2013 Tabriz 140 10 Morphology
Mirhossaini32 - 2009 Khorram-abad 240 100 Morphology
Yazdanbakhsh33 2015 2016 Shahroud 562 0 ELISA
Ajami34 2009 2012 Mashhad 52 19 PCR
MAG Moghadam35 2011-2012 2013 Rasht 140 12 PCR
MAG Moghadam et al.36 2014 2015 Guilan 135 12 PCR
MAG Moghadam and Honarmand37 2014 2016 Guilan 63 6 Morphology
Moosavian and Khosro Shahi38 - 2004 Ahvaz 210 14 Morphology, PCR
Moosavian and Dashti39 - 2011 Khuzestan 150 33 PCR
Ahmadinejad40 2006 2011 Kerman 77 30 Nested real-time PCR
Ahmadrajab41 2015 2016 Kerman and Bam 128 29 Morphology
Alipour42 2011 2013 Bandar Abbas 66 15 PCR

Figure2.

Figure2

Forest plot of the meta-analysis for Legionella species prevalence of water resources. It shows the assortment of studies based on the criterion that have the best effect and indicate the weighted average and effect of each study with respect to the total study.

Overall Effects

Based on the heterogeneity test, there were heterogeneities between the studies (Q2=173.623, I2=91.42, t=291.3, P<0.001). Thus the random model was used to combine the prevalence of Legionella species in water resources. table 2 shows that the combined Legionella species prevalence in water resources of Iran was 27.3% (95% CI: 25.3-29.3). To evaluate the weight of each study in this meta-analysis, the forest plot test was used (figure 2).

Table 2.

Subgroups analysis for Legionella of water resources

Subgroups Number of studies Heterogeneity test Egger’s test Random model
NTM prevalence (95% Cl (%)) Z P value Q P value I2 t P value
Overall effect 26 27.3 (25.3-29.3) 19.1 <0.001 291.3 <0.001 91.4 1.9 0.05
Hospital water 16 28.8 (26.4-31.2) 15.03 <0.001 139.5 <0.001 89.2 1.9 0.07
Dental settings water 3 3.6 (16.1-33.2) 4.8 <0.001 26.4 <0.001 92 4.9 0.01
Other water resources 7 29.6 (25.6-33.8) 8.6 0.06 134.4 95.5 0.2 0.84
Based on Legionella species
L. pneumophila 19 60.5 (53.3-67.2) 2.8 0.004 75.5 <0.001 76.1 17 <0.001
Other species 7 52.5 (44.7-60.2) 63.6 0.52 9.1 0.16 34.5 5 0.35
Based on location
Tehran 8 27.9 (24.5-31.5) 1.45 <0.001 18.02 0.12 61.1 1.7 0.12
Isfahan 5 55.7 (48.0-63.0) 7.5 0.14 39.8 <0.001 89.9 2.7 0.07
Zanjan 1 20.8 (14.4-29.0) 5.9 - - - - - -
Tabriz 1 7.1 (3.9-12.8) 7.8 - - - - - -
Guilan 3 8.9 (6.3-12.4) 12.17 <0.001 0.05 0.97 0.00 2.17 0.27
Khorram-abad 1 41.7 (35.6-48.0) 2.57 0.01 0.00 1.00 0.00 - -
Shahroud 1 0.001 (0.0-0.014) 4.9 <0.001 0.00 1.00 0.00 - -
Ahvaz 2 11.1 (8.1-14.9) 11.8 <0.001 6.8 0.01 85.2 - -
Kerman 2 29.4 (23.4-36.1) 5.6 <0.001 6.1 0.01 83.6 - -
Bandar Abbas 1 22.7 (14.2-34.3) 4.1 <0.001 0.00 1.00 0.00 - -
Mashhad 1 36.6 (24.7-50.3) 1.9 0.05 - 1.00 0.00 - -

Subgroups Analysis for Legionella Species of Water Resources

According to the subgroups analysis, the prevalence of Legionella spp. in hospital water, dental settings water and other water resources were 28.8% (95% CI: 26.4-31.2), 23.6% (95% CI: 16.1-33.2), and 29.6% (95% CI: 25.6-33.8), respectively (table 2). ). As evident in table 2, the most common species of Legionella was related to the L. pneumophila with a prevalence of 60.5% (95% CI: 53.3-67.2) and the prevalence of all other species was 52.5% (95% CI: 44.7-60.2). Based on the location, the highest prevalence was reported in Isfahan with a rate of 55.7% (95% CI: 48.0-63.0) followed by Tehran with the prevalence of 27.9% (95% CI: 24.5-31.5).

Discussion

Overall, the combined prevalence of Legionella species in water resources of Iran was 27.3%. This prevalence is low compared to other countries which might be due to the fastidious growth of this bacterium, the need for special skills to grow, and the presence/lack of inhibitors to control the samples. As mentioned in our results, the prevalence varied from 0% to 70%. Such significant variation in prevalence is possibly related to the sampling from different geographical locations, number of samples, the sample size for concentration and filtration, type of water systems (hot and cold), and water quality.43 Based on the report of the CDC, the prevalence of legionellosis disease in hospitals is between 25% to 45%,44 and the death rate from this disease in hospitals is 30%.45 Our results showed that the prevalence of Legionella spp. in hospital water, dental settings water, and other water resources were 28.8%, 23.6%, and 29.6%, respectively. Since all hospitals in Tehran, and probably throughout the country, obtain their water supply from the municipal water suppliers, the presence of Legionella in hospital water system indicates a high resistance of this organism to adverse environmental conditions. Therefore, water treatment operations and disinfection with chlorine must be used by modern methods (e.g. simultaneous ozonation and disinfection combination method) to remove Legionalla.46 The results of several studies show that even the concentration of trace elements (iron, manganese, zinc, and copper), water hardness, and alkalinity in hospital water is effective against the presence of Legionella and its density.15,24 As stated, 23.6% of dental settings water is contaminated with Legionella, which is an alarming rate. As shown previously, dental staff had a higher degree of positivity for L. pneumophila serum antibodies.47 Turetgen et al. (2009) showed that the microbial contamination of water in dental units was high for L. pneumophila.48 The use of waterline system coated with disinfectants, use of separate water source in dental settings for easy disinfection, and designing biofilm removal systems should all be considered for the reduction of Legionella spp.

Our meta-analysis, consistent with all studies conducted in other regions of the world, revealed that L. peneumophila had the most frequent occurrence in all water resources of Iran. Studies have shown that in America and Europe, 70% to 90% of legionellosis infection incidences are related to L. peneumophila.49 Based on the studies in the United States, from 2003 to 2005, an average of 2,000 people were infected each year by contaminated water.50

No difference between detection by PCR and conventional culture was observed in the Iranian studies while theoretically, PCR should provide higher sensitivity than the culture method.51 However, sometimes PCR is inhibited by inhibitors and unknown materials and the report of Legionella is based on CFU in the culture method but PCR does not comply with this rule.52 A standard method for the detection of Legionella species in environmental water is to use culture techniques. However, these have a number of limitations such as the slow growth rate of Legionella and commonly 3-10 days is necessary for incubation. Furthermore, only culturable isolates are detectable in this method and treatment with acid may cause damage and leads to stress in Legionella.53 However, the PCR technique detects both the living and dead cells,54 and probably for this reason no isolate was detected in one of the studies conducted by Yazdanbakhsh et al. (2015).

France, Italy, and most European countries determined and confirmed 10,000 CFU/l as the risk threshold for water contamination with Legionella bacterium in water distribution network systems. If the pollution exceeds this amount, control measures are necessary.55,56 Concentrations above this rate of culturable Legionella may increase the risk of human infection.57 Regarding the importance of Legionella bacterium in water resources, particularly in hospital water, and its transfer to patients in sensitive wards such as ICU and CCU, control measures such as treatment operation and disinfection with chlorine and modern methods (ozonation and simultaneous disinfection combination method) are necessary.

The strength of this study is that an extensive search of multiple databases was conducted to identify appropriate articles. Additionally, article selection was carried out independently by two researchers. In case of disagreement between researchers, this was resolved through internal discussions. The meta-analysis was performed in accordance with the available published guidelines (PRISMA, http://www.prisma-statement.org) and subgroups analysis was also performed to reduce heterogeneity. The present study has some limitations which have to be pointed out. We were not aware of past studies with unpublished results and hence they were not included in the present study. Additionally, we did not contact the authors of the included studies to obtain further data in cases where clarification was required. Thus, the meta-analysis was performed only based on the available information in selected studies.

Conclusion

Based on the results of the present study, the prevalence rate of Legionella species in water resources of Iran was high and the most common Legionella species was L. pneumophila.

Acknowledgement

We would like to thank Alireza Tafazzoli for his assistance with data analysis.

Conflict of Interest:None declared.

References

  • 1.Allegra S, Grattard F, Girardot F, Riffard S, Pozzetto B, Berthelot P. Longitudinal evaluation of the efficacy of heat treatment procedures against Legionella spp. in hospital water systems by using a flow cytometric assay. Appl Environ Microbiol. 2011;77:1268–75. doi: 10.1128/AEM.02225-10. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Gaia V, Casati S, Tonolla M. Rapid identification of Legionella spp. by MALDI-TOF MS based protein mass fingerprinting. Syst Appl Microbiol 2011;34:40–4. doi: 10.1016/j.syapm.2010.11.007. [DOI] [PubMed] [Google Scholar]
  • 3.Huang SW, Hsu BM, Wu SF, Fan CW, Shih FC, Lin YC, et al. Water quality parameters associated with prevalence of Legionella in hot spring facility water bodies. Water Res. 2010;44:4805–11. doi: 10.1016/j.watres.2010.07.063. [DOI] [PubMed] [Google Scholar]
  • 4.Newton HJ, Ang DK, van Driel IR, Hartland EL. Molecular pathogenesis of infections caused by Legionella pneumophila. Clin Microbiol Rev. 2010;23:274–98. doi: 10.1128/CMR.00052-09. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Miyamoto H, Yamamoto H, Arima K, Fujii J, Maruta K, Izu K, et al. Development of a new seminested PCR method for detection of Legionella species and its application to surveillance of legionellae in hospital cooling tower water. Appl Environ Microbiol. 1997;63:2489–94. doi: 10.1128/aem.63.7.2489-2494.1997. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Fields BS, Benson RF, Besser RE. Legionella and Legionnaires’ disease: 25 years of investigation. Clin Microbiol Rev. 2002;15:506–26. doi: 10.1128/CMR.15.3.506-526.2002. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Yu VL. Cooling towers and legionellosis: A conundrum with proposed solutions. Int J Hyg Environ Health. 2008;211:229–34. doi: 10.1016/j.ijheh.2008.02.003. [DOI] [PubMed] [Google Scholar]
  • 8.Osterholm MT, Chin TD, Osborne DO, Dull HB, Dean AG, Fraser DW, et al. A 1957 outbreak of Legionnaires’ disease associated with a meat packing plant. Am J Epidemiol. 1983;117:60–7. doi: 10.1093/oxfordjournals.aje.a113516. [DOI] [PubMed] [Google Scholar]
  • 9.Joly P, Falconnet PA, Andre J, Weill N, Reyrolle M, Vandenesch F, et al. Quantitative real-time Legionella PCR for environmental water samples: data interpretation. Appl Environ Microbiol. 2006;72:2801–8. doi: 10.1128/AEM.72.4.2801-2808.2006. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Jonas D, Rosenbaum A, Weyrich S, Bhakdi S. Enzyme-linked immunoassay for detection of PCR-amplified DNA of legionellae in bronchoalveolar fluid. J Clin Microbiol. 1995;33:1247–52. doi: 10.1128/jcm.33.5.1247-1252.1995. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Stout JE, Muder RR, Mietzner S, Wagener MM, Perri MB, DeRoos K, et al. Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: A national surveillance study with clinical correlations. Infect Control Hosp Epidemiol. 2007;28:818–24. doi: 10.1086/518754. [DOI] [PubMed] [Google Scholar]
  • 12.Delgado-Viscogliosi P, Simonart T, Parent V, Marchand G, Dobbelaere M, Pierlot E, et al. Rapid method for enumeration of viable Legionella pneumophila and other Legionella spp. in water. Appl Environ Microbiol 2005;71:4086–96. doi: 10.1128/AEM.71.7.4086-4096.2005. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Hay J, Seal DV, Billcliffe B, Freer JH. Non-culturable Legionella pneumophila associated with Acanthamoeba castellanii: Detection of the bacterium using DNA amplification and hybridization. J Appl Bacteriol. 1995;78:61–5. doi: 10.1111/j.1365-2672.1995.tb01674.x. [DOI] [PubMed] [Google Scholar]
  • 14.Moghadam MAJ, Honarmand H, Asfaram S. Investigation Detection of pathogenic Legionella pneumophila including mip Gene in tap water and water of newborn incubators in hospitals of Guilan Province by PCR of mip gene. Br Microbiol Res J. 2014;4:1531–40. [Google Scholar]
  • 15.Bargellini A, Marchesi I, Righi E, Ferrari A, Cencetti S, Borella P, et al. Parameters predictive of Legionella contamination in hot water systems: Association with trace elements and heterotrophic plate counts. Water Res. 2011;45:2315–21. doi: 10.1016/j.watres.2011.01.009. [DOI] [PubMed] [Google Scholar]
  • 16.Aslani MM, Pourmansour M, Motavalian M. Isolation of Legionella pneumophila from Tehran Hospital water samples. Iran Biomed J. 1997;1:65–7. [Google Scholar]
  • 17.Hosseinidoust S, Mohabati MA, Hajia M. Molecular detection of legionella pneumophila within culture-negative samples. Yakhteh Med J. 2003;4:219–23. [Google Scholar]
  • 18.Doust RH, Mobarez AM, Esmailli D. Detection of Legionella in hospital water supply using mip based primers. Int J Biol Sci. 2008;8:930–4. [Google Scholar]
  • 19.Mobarez A, Hoeeini DR, Esmaeili D. Detection and control of legionella in hospital water distribution and condition systems. J Biol Sci. 2007;8:930–934. [In Persian] [Google Scholar]
  • 20.Eslami A, Momayyezi MH, Esmaili D, Joshani GH. Presence of Legionella pneumophila and environmental factors affecting its growth, in the water distribution system in Taleghani hospital, Tehran. Pajoohandeh Journal. 2012;17:32–7. [In Persian] [Google Scholar]
  • 21.Rafiee M, Mesdaghinia A, Hajjaran H, Hajaghazadeh M, Miahipour A, Jahangiri-Rad M. The Efficacy of Residual Chlorine Content on the Control of Legionella Spp. In Hospital Water Systems. Iran J Public Health 2014;43:637–44. [ PMC Free Article] [PMC free article] [PubMed] [Google Scholar]
  • 22.Esmaieli D, Mohebati-mobarez A, Hosaini Dust SR. Frequency of legionella contamination in conditional & water distribution systems of Tehran hospitals. Iran South Med J. 2008;11:55–60. [In Persian] [Google Scholar]
  • 23.Yaslianifard S, Mobarez AM, Fatolahzadeh B, Feizabadi MM. Colonization of hospital water systems by Legionella pneumophila, Pseudomonas aeroginosa, and Acinetobacter in ICU wards of Tehran hospitals. Indian J Pathol Microbiol. 2012;55:352–6. doi: 10.4103/0377-4929.101743. [DOI] [PubMed] [Google Scholar]
  • 24.Mirmohamadlou A, Ghanizadeh G, Esmaeili D. Correlation between Legionella Water Contamination and Microelements in Water Lines of Selected Hospitals in Tehran. Journal of Mazandaran University of Medical Sciences. 2016;25:245–54. [In Persian] [Google Scholar]
  • 25.Baghal Asghari F, Nikaeen M, Hatamzadeh M, Vahid Dastjerdi M, Hassanzadeh A. Detection of Legionella Spp. in Water from Cooling Towers. Journal of Isfahan Medical School. 2012;30 [In Persian] [Google Scholar]
  • 26.Baghal Asghari F, Nikaeen M. Sensitivity Comparison of Different 16s rDNA-Specific Primers for Detection of Legionella Species in Aquatic Samples. Iranian Journal of Health and Environment. 2012;5:263–72. [Google Scholar]
  • 27.Asghari FB, Nikaeen M, Hatamzadeh M, Hassanzadeh A. Surveillance of Legionella species in hospital water systems: The significance of detection method for environmental surveillance data. J Water Health. 2013;11:713–9. doi: 10.2166/wh.2013.064. [DOI] [PubMed] [Google Scholar]
  • 28.Attar HM, Shahmansouri M, Neshat A, Fazeli M. Identification of Legionella in the hot water supply of a general hospital in Isfahan. Journal of Research in Medical Sciences. 2004;9:289–93. [Google Scholar]
  • 29.Ghalyani P, Karami M, Havaei A, Naderi A, Alikhani M. Contamination of Dental Scaler Waterlines with Legionella Pneumophila, Pseudomonas Aeruginosa and Gram Positive Cocci. Journal of Islamic Dental Association of IRAN (JIDAI) 2015;27:1. [In Persian] [Google Scholar]
  • 30.Motaharinia Y, Shapouri R, Rahnema M, Rahmani MR, Rezaie MA. Evaluation of the Immunogenic effect of lipopolysaccharide (LPS) and protein fractions of Legionella pneumophila in challenging with lethal dose of this bacterium in mice. Scientific Journal of Kurdistan University of Medical Sciences. 2011;16:20–30. [In Persian] [Google Scholar]
  • 31.Ghotaslou R, Yeganeh Sefidan F, Akhi MT, Soroush MH, Hejazi MS. Detection of legionella contamination in tabriz hospitals by PCR assay. Adv Pharm Bull. 2013;3:131–4. doi: 10.5681/apb.2013.022. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Mirhossaini SH, Mohammadi M, Birjandi M, Kamarehi B, jafari A, Hoseinzadegan H, et al. Contamination of water reservoirs to Legionella in khorramabad hospitals. yafte. 2009; 11 (2):27–31. [In Persian] [Google Scholar]
  • 33.Yazdanbakhsh A, Roudbari AA, Nazemi S, Mirzai M, Davardoost F, Norozi P, et al. Evaluation of Bacterial Contamination of Water Supply in Dental Unit Water Lines at Shahroud Dental Offices 2015. Journal of Knowledge & Health. 2015;11:49–54. [In Persian] [Google Scholar]
  • 34.Ajami B, Ghazvini K, Movahhed T, Ariaee N, Shakeri M, Makarem S. Contamination of a dental unit water line system by legionella pneumophila in the mashhad school of dentistry in 2009. Iran Red Crescent Med J. 2012;14:376–8. [ PMC Free Article] [PMC free article] [PubMed] [Google Scholar]
  • 35.Ahmadi Jalali Moghadam M, Honarmand H, Asfaram Meshginshahr S, Soltani Tehrani B, Nojavan M. Frequency of Legionella Pneumophila in Tap Water and Water of Infant Incubators in Guilan Hospitals, Iran. Journal of Mazandaran University of Medical Sciences. 2013;23:312–21. [In Persian] [Google Scholar]
  • 36.Ahmadi Jalali Moghadam M, Honarmand H, Asfaram Meshginshahr S. Contamination of Hospital Water Supplies in Gilan, Iran, with Legionella pneumophila, Escherichia coli, and Pseudomonas aeruginosa. Interdiscip Perspect Infect Dis. 2015;2015:809842. doi: 10.1155/2015/809842. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar] [Retracted]
  • 37.Moghadam MAJ, Honarmand H, Meshginshahr SA. Contamination of Tap Water with Pseudomonas aeruginosa, Legionella pneumophila, and Escherichia coli in Guilan, Iran. J Med Bacteriol. 2016;5:21–8. [Google Scholar]
  • 38.Moosavian S, Divan Khosro Shahi N. Survey of Legionnaires’ Disease Agents in Therapeutic Equipments and Drinking Water Sources in Ahwaz, Iran. ournal of Guilan University of Medical Sciences. 2004;13:38–44. [In Persian] [Google Scholar]
  • 39.Mojtaba M, Amir D. Isolation and identification of legionellosis agents from fishponds, swimming pools and cooling towers in Khuzestan province, Iran. Jundishapur J Microbiol. 2017;2011:209–215. [Google Scholar]
  • 40.Ahmadinejad M, Shakibaie MR, Shams K, Khalili M. Detection of Legionella pneumophila in cooling water systems of hospitals and nursing homes of Kerman city, Iran by semi-nested PCR. World Acad Sci Eng Technol. 2011;76:20–3. [Google Scholar]
  • 41.Ahmadrajabi R, Shakibaie MR, Iranmanesh Z, Mollaei HR, Sobhanipoor MH. Prevalence of mip virulence gene and PCR-base sequence typing of Legionella pneumophila from cooling water systems of two cities in Iran. Virulence. 2016;7:602–9. doi: 10.1080/21505594.2016. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Alipour V, Mahvi AH, Rezaei L. Quantitative and qualitative characteristics of condensate water of home air-conditioning system in Iran. Desalination Water Treat. 2015;53:1834–9. [Google Scholar]
  • 43.Ghanizadeh G, Mirmohammadlou A, Esmaeili D. Survey of legionella water resources contamination in Iran and foreign countries: A Systematic Review. Iranian Journal of Medical Microbiology. 2016;9:1–15. [Google Scholar]
  • 44.Zhang Z, McCann C, Hanrahan J, Jencson A, Joyce D, Fyffe S, et al. Legionella control by chlorine dioxide in hospital water systems. J Am Water Works Assoc. 2009;101:117. [Google Scholar]
  • 45.Campese C, Bitar D, Jarraud S, Maine C, Forey F, Etienne J, et al. Progress in the surveillance and control of Legionella infection in France, 1998-2008. Int J Infect Dis. 2011;15:e30–7. doi: 10.1016/j.ijid.2010.09.007. [DOI] [PubMed] [Google Scholar]
  • 46.Berry D, Xi C, Raskin L. Microbial ecology of drinking water distribution systems. Curr Opin Biotechnol. 2006;17:297–302. doi: 10.1016/j.copbio.2006.05.007. [DOI] [PubMed] [Google Scholar]
  • 47.Pouralibaba F, Balaei E, Kashefimehr A. Evaluation of gram negative bacterial contamination in dental unit water supplies in a university clinic in tabriz, iran. J Dent Res Dent Clin Dent Prospects. 2011;5:94–7. doi: 10.5681/joddd.2011.021. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Turetgen I, Goksay D, Cotuk A. Comparison of the microbial load of incoming and distal outlet waters from dental unit water systems in Istanbul. Environ Monit Assess. 2009;158:9–14. doi: 10.1007/s10661-008-0560-7. [DOI] [PubMed] [Google Scholar]
  • 49.Ditommaso S, Giacomuzzi M, Gentile M, Zotti CM. Antibody detection and cross-reactivity among species and serogroups of Legionella by indirect immunofluorescence test. J Microbiol Methods. 2008;75:350–3. doi: 10.1016/j.mimet.2008.06.002. [DOI] [PubMed] [Google Scholar]
  • 50.Carratala J, Garcia-Vidal C. An update on Legionella. Curr Opin Infect Dis. 2010;23:152–7. doi: 10.1097/QCO.0b013e328336835b. [DOI] [PubMed] [Google Scholar]
  • 51.Villari P, Motti E, Farullo C, Torre I. Comparison of conventional culture and PCR methods for the detection of Legionella pneumophila in water. Lett Appl Microbiol. 2011998;27:106–10. doi: 10.1046/j.1472-765x.1998.00389.x. [DOI] [PubMed] [Google Scholar]
  • 52.Maiwald M, Kissel K, Srimuang S, von Knebel Doeberitz M, Sonntag HG. Comparison of polymerase chain reaction and conventional culture for the detection of legionellas in hospital water samples. J Appl Bacteriol. 1994;76:216–25. doi: 10.1111/j.1365-2672.1994.tb01619.x. [DOI] [PubMed] [Google Scholar]
  • 53.Edagawa A, Kimura A, Doi H, Tanaka H, Tomioka K, Sakabe K, et al. Detection of culturable and nonculturable Legionella species from hot water systems of public buildings in Japan. J Appl Microbiol. 2008;105:2104–14. doi: 10.1111/j.1365-2672.2008.03932.x. [DOI] [PubMed] [Google Scholar]
  • 54.Yaradou DF, Hallier-Soulier S, Moreau S, Poty F, Hillion Y, Reyrolle M, et al. Integrated real-time PCR for detection and monitoring of Legionella pneumophila in water systems. Appl Environ Microbiol. 2007;73:1452–6. doi: 10.1128/AEM.02399-06. [ PMC Free Article] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 55.Tai J, Benchekroun MN, Mekkour M, Ennaji MM, Nader H, Cohen N. Investigation of Legionella Pneumophila in Hot Water Systems in Morocco. Int J Sci Technol. 2012;1:524–30. [Google Scholar]
  • 56.Stojek NM, Szymanska J, Dutkiewicz J. Gram-negative bacteria in water distribution systems of hospitals. Ann Agric Environ Med. 2008;15:135–42. [PubMed] [Google Scholar]
  • 57.Meenhorst PL, Reingold AL, Groothuis DG, Gorman GW, Wilkinson HW, McKinney RM, et al. Water-related nosocomial pneumonia caused by Legionella pneumophila serogroups 1 and 10. J Infect Dis. 1985;152:356–64. doi: 10.1093/infdis/152.2.356. [DOI] [PubMed] [Google Scholar]