Endothelial parameters in central and peripheral cornea in patients wearing contact lenses

Saulius Galgauskas 1, Justina Ignataviciute 1, Zivile Vieversyte 2, Rimvydas Asoklis 1
PMCID: PMC6232331  PMID: 30450306

Abstract

AIM

To measure the parameters of endothelium in the central and peripheral parts of the cornea and evaluate the influence of wearing the hard and soft contact lenses on the mentioned parameters.

METHODS

A specular microscope was used to measure the corneal endothelium parameters in both eyes of 139 Caucasians (a total of 278). All participants were divided into three groups: soft lens wearers, hard lens wearers and a control group. Factors, such as age, smoking, types of lens material, duration of lens wear and lens air permeability were assessed to determine their impact on the morphometric parameters of the endothelium.

RESULTS

A lower percentage of hexagon-like cells and higher cell variation than in other groups were determined in hard contact lens wearers. The difference in density of endotheliocytes between the groups was not observed. The measurements of the morphometric parameters in soft contact lens wearers did not depend neither on the duration of lens wear, nor on air permeability. The relation between the patients' age and the variation of endothelium parameters was determined in the group of hard contact lens wearers.

CONCLUSION

Wearing hard contact lenses provokes pleomorphism and polymegethism of the corneal endothelium, while soft contact lenses do not impact any parameters of the endothelium, most likely due to higher air permeability.

Keywords: corneal endothelium, morphometry, endothelial changes, contact lenses

INTRODUCTION

Injuries of the corneal endothelium are related to a variety of eye diseases, such as corneal distrophies, critical reduction in the density of endotheliocytes, named as the most common cause of the corneal transplant rejection within five years after transplantation[1], and recently determined relation between density of endotheliocytes and expression of the symptoms of dry eye syndrome[2]. In order to standardize the degree of the corneal endothelial damage, the classification, based on the density of endotheliocytes and corneal changes identified during ophthalmobiomicroscopy, was suggested in 2014[3].

The studies describing the density of endotheliocytes not only in central but also in the peripheral cornea in vivo appeared already in 1977[4]. With the possibility of measuring endothelial parameters in the periphery using more and more automated and patient-friendly methods, this was started in order to more accurately predict endothelium changes and their effects after various interventions (e.g. LASIK, lamellar keratoplasty), and to specifically investigate the potential of endotheliocytes regeneration/proliferation at the corneal periphery which could be used to treat endothelial damage effectively[5][8].

The aim of this research is to measure the corneal endothelium parameters in the central and peripheral corneal areas and to determine the influence of the wear of soft and hard contact lenses on changes in these parameters in the Lithuanian population.

SUBJECTS AND METHODS

After receipt of an informed consent, 139 Caucasian patients (a total of 278 eyes) were involved to the research. Totally 31 males and 108 females at the age from 18 to 68 (33.12±19.97)y were involved. All participants had no anterior segment diseases, diabetes mellitus, no eye injuries or surgical treatment in anamnesis. All of them were divided into three groups: soft contact lens wearers (SCL), hard contact lens wearers (HCL) and a control group (CG) which included participants who have never worn contact lenses. Patients' anamnesis was collected on the following: age, sex, smoking, duration of contact lenses wear, type of contact lenses (daily-wear/ monthly-wear/ conventional-wear), type of contact lens material [silicone (Si)/ hydrogel (Hy)/ silicone-hydrogel (SiHy)/ rigid gas permeable (RGP)/ polymethyl methacrylate (PMMA)].

Central corneal thickness (CCT) and parameters of endothelium were assessed in central and six peripheral points of the cornea using a specular microscope (Topcon SP-1P). Examination of the endothelium included endothelial cell density (ECD), polymegethism (variation of cells size-CV %) and pleomorphism (percentage of hexagon-like cells-HEX %). Only the data obtained after measuring at least 60 endotheliocytes were used in the research.

IBM SPSS® 20.0 (IBM Corporation, Armonk, NY, USA) and Microsoft Excel® 2007 (Microsoft Corporation, Redmond, WA, USA) were used for the statistical analysis. Student's t-test and Pearson's correlation coefficient (r) values were calculated. The data were considered statistically significant at P<0.05.

This study was approved by the Human Ethics Committee of Vilnius University Faculty of Medicine.

RESULTS

The CG included 67 participants: 20 males and 47 females aged from 21 to 68 (32.64±13.18)y. The group of the SCL consisted of 37 participants [6 males and 31 females aged from 23 to 45 (25±3.05)y] and the group of the HCL had 40 patients: 5 males and 35 females at the age from 18 to 64 (42±12.81)y.

Distribution of endothelial parameters in the examined points is shown in Table 1 (CG), Table 2 (HCL) and Table 3 (SCL). ECD varied from 1678.5 to 4421 cells/mm2 and in superior corneal point was statistically significantly higher in all groups (P=0.002; Figure 1). ECD in the central cornea in CG and HCL groups was statistically significantly lower than in the peripheral points (P=0.002; Figure 1). Statistically significant ECD difference between all groups was not observed in any of the examined corneal points [center (C) P=0.02, superior (S) P=0.04, inferior (I) P=0.25, nasosuperior (NS) P=0.1, nasoinferior (NI) P=0.09, temporosuperior (TS) P=0.02, temporoinferior (TI) P=0.04].

Table 1. Corneal endothelium parameters values in control group.

Parameters Localization Mean SD
Endothelial cell density (cell/mm2) Central 2899.22 295.74
Superior 3346.52 420.70
Inferior 2986.15 320.12
Nasosuperior 2980.49 325.87
Nasoinferior 2986.58 316.95
Temporosuperior 3064.08 343.04
Temporoinferior 3029.38 336.61
Polymegethism (%) Central 29.91 3.34
Superior 33.50 5.00
Inferior 30.05 4.08
Nasosuperior 30.56 4.46
Nasoinferior 30.05 4.48
Temporosuperior 31.05 4.19
Temporoinferior 29.45 3.67
Pleomorphism (%) Central 57.35 6.82
Superior 55.24 7.49
Inferior 59.80 6.69
Nasosuperior 62.45 8.21
Nasoinferior 60.88 7.63
Temporosuperior 59.40 7.62
Temporoinferior 57.35 6.82

SD: Standard deviation.

Table 2. Corneal endothelium parameters values in hard contact lens wearers.

Parameters Localization Mean SD
Endothelial cell density (cell/mm2) Central 2982.41 365.02
Superior 3249.02 430.16
Inferior 3078.60 401.45
Nasosuperior 3108.00 366.33
Nasoinferior 3089.41 428.86
Temporosuperior 3194.80 407.21
Temporoinferior 3078.14 423.05
Polymegetism (%) Central 36.04 4.21
Superior 36.32 6.08
Inferior 34.84 5.44
Nasosuperior 35.42 6.46
Nasoinferior 34.10 5.53
Temporosuperior 35.10 4.70
Temporoinferior 33.35 3.61
Pleomorphism (%) Central 48.52 7.27
Superior 48.97 5.99
Inferior 51.04 6.34
Nasosuperior 52.54 7.78
Nasoinferior 54.41 9.32
Temporosuperior 51.62 6.37
Temporoinferior 48.52 7.27

SD: Standard deviation.

Table 3. Corneal endothelium parameters values in soft contact lens wearers.

Parameters Localization Mean SD
Endothelial cell density (cell/mm2) Central 3084.66 345.92
Superior 3479.91 313.19
Inferior 3079.31 266.93
Nasosuperior 3103.54 352.63
Nasoinferior 3126.75 267.89
Temporosuperior 3241.44 270.62
Temporoinferior 3206.72 266.24
Polymegetism (%) Central 29.81 3.09
Superior 32.05 4.81
Inferior 29.08 3.25
Nasosuperior 29.21 3.34
Nasoinferior 29.33 3.17
Temporosuperior 30.04 3.38
Temporoinferior 28.94 2.93
Pleomorphism (%) Central 56.56 6.82
Superior 58.44 7.67
Inferior 60.40 8.01
Nasosuperior 63.79 7.04
Nasoinferior 61.52 8.41
Temporosuperior 60.75 7.40
Temporoinferior 56.56 6.82

SD: Standard deviation.

Figure 1. Distribution of the endothelial cell density in various corneal points.

Figure 1

The lowest CV was measured in the CG (20%), the highest in the group of HCL and the CG (52.50%). CV in HCL group was statistically significantly higher than in SCL and CG (P<0.001; Figure 2). The lowest HEX was measured in HCL group (28.5%), the highest in CG (81%). HEX in HCL group was statistically significantly lower than in SCL and CG (P<0.001; Figure 3).

Figure 2. Distribution of megethism in various corneal points.

Figure 2

Figure 3. Distribution of pleomorphism in various corneal points.

Figure 3

Average measurement of CCT was 528.25±37.01 µm (ranged from 452 to 662 µm). CCT measured in the CG was 526.82±38.73 µm (ranged from 370 to 623 µm). In the SCL group 534.05±35.18 µm (ranged from 468 to 662 µm), HCL group 524.85±35.85 µm (ranged from 452 to 584 µm). Statistically significant CCT difference between all groups was not observed (P=0.52). Neither ECD, nor CV or HEX did not depend on CCT (P values, respectively, 0.41, 0.74 and 0.66).

There was a weak negative correlation between ECD and HEX with age in the CG (Table 4).

Table 4. Correlation between endothelial parameters and age.

Group Parameters P (Pearson) Correlation
Control Endothelial cell density 0.000 -0.490
Polymegethism 0.273
Pleomorphism 0.000 -0.430
Soft contact lens Endothelial cell density 0.131
Polymegethism 0.152
Pleomorphism 0.116
Hard contact lens (PMMA/RGP) Endothelial cell density 0.259
Polymegethism 0.033
Pleomorphism 0.731

The CG included 9 smokers and 58 non-smokers. The group of SCL had 13 and 24, and the group of HCL had 5 and 30, respectively. In total there were 27 smokers and 112 non-smokers. In SCL group, longer time of smoking was associated with a reduction in the values of ECD (Table 5). According to the significance value, there was no correlation between the parameters and smoking (Table 6).

Table 5. Correlation between endothelial parameters and duration of smoking.

Groupa Parameters (periphery) P (Pearson) Correlation
Control Endothelial cell density 0.878
Polymegethism 0.098
Pleomorphism 0.022
Soft contact lens Endothelial cell density 0.004 -0.742
Polymegethism 0.238
Pleomorphism 0.424
Hard contact lens (PMMA/RGP) Endothelial cell density 0.886
Polymegethism 0.396
Pleomorphism 0.126

aAll participants-smokers.

Table 6. Correlation between endothelial parameters and smoking.

Group S+/S- Parameters Mean SD P (Pearson)
Control Smokers (S+) Endothelial cell density 2896.73 cell/mm2 312.68 0.200
Polymegethism 32.69% 4.99 0.200
Pleomorphism 57.95% 6.29 0.177
Non-smokers (S-) Endothelial cell density 3091.73 cell/mm2 312.68 0.200
Polymegethism 30.48% 3.72 0.078
Pleomorphism 59.38% 5.99 0.200
Soft contact lens S+ Endothelial cell density 3197.46 cell/mm2 277.35 0.200
Polymegethism 30.23% 3.40 0.200
Pleomorphism 60.39% 6.09 0.200
S- Endothelial cell density 3211.05 cell/mm2 247.77 0.200
Polymegethism 29.53% 2.76 0.200
Pleomorphism 60.17% 6.31 0.117
Hard contact lens (PMMA/RGP) S+ Endothelial cell density 2880.63 cell/mm2 411.19 0.146
Polymegethism 32.70% 4.18 0.200
Pleomorphism 52.31% 5.69 0.200
S- Endothelial cell density 3175.05 cell/mm2 334.40 0.062
Polymegethism 35.21% 4.58 0.200
Pleomorphism 51.00% 5.43 0.200

SD: Standard deviation.

The duration of lenses wear in SCL group varied from 3 to 144mo (62.54±40.63mo). In this group, there was no correlation between duration and other parameters (Table 7). Daily-wear lenses were worn by 1 (2.7%), monthly-wear by 36 (97.3%) participants. This is why the impact of lenses wearing mode was not evaluated. Permeability of oxygen in SCL group varied from 19.7 to 175. Permeability of oxygen had no statistically significant impact on the studied parameters (Table 8). Using the linear regression method and measuring influence of permeability of oxygen, duration of lens wear and mode, on all parameters of endothelium, revealed that none of these factors had more impact than others (Table 9).

Table 7. Correlation between endothelial parameters and duration of soft contact lens wear.

Parameters P
Central-endothelial cell density 0.068
Central-polymegethism 0.109
Central-pleomorphism 0.160
Peripheral-endothelial cell density 0.508
Peripheral-polymegethism 0.384
Peripheral-pleomorphism 0.630

Table 8. Correlation between endothelial parameters and soft contact lens permeability of oxygen.

Parameters P
Central-endothelial cell density 0.845
Central-polymegethism 0.385
Central-pleomorphism 0.526
Peripheral-endothelial cell density 0.688
Peripheral-polymegethism 0.516
Peripheral-pleomorphism 0.381

Table 9. Various predictors impact on endothelial parameters in soft contact lens group.

Parameters Predictors P
Central-endothelial cell density Dk/t 0.948
Duration 0.518
Schedule 0.127
Central-polymegethism Dk/t 0.711
Duration 0.194
Schedule 0.252
Central-pleomorphism Dk/t 0.954
Duration 0.031
Schedule 0.200
Peripheral-endothelial cell density Dk/t 0.319
Duration 0.614
Schedule 0.010
Peripheral-polymegethism Dk/t 0.757
Duration 0.540
Schedule 0.303
Peripheral-pleomorphism Dk/t 0.736
Duration 0.119
Schedule 0.275

In HCL group PMMA lenses were worn by 11 (31.42%) participants, RGP by 8 (22.85%) participants. Totally 16 (45.71%) patients at first wore PMMA lenses which later were changed into RGP-these participants were assessed as mixed wearers. The type of contact lens material did not make any statistically significant impact on endothelial parameters. Measuring in the central cornea (C) ECD P=0.206, CV P=0.146, HEX P=0.491, in the peripheral cornea (P) ECD P=0.029, CV P=0.070, HEX P=0.048. PMMA lenses were being worn from 12 to 492 (242.33±122.71)mo, Boston XO from 24 to 204 (112.83±53.20)mo. PMMA lenses were being worn statistically significantly longer than Boston XO (P=0.000). Duration of lenses wear did not have any impact on endothelium parameters (C) ECD P=0.903, CV P=0.069, HEX P=0.249, (P) ECD P=0.682, CV P=0.012, HEX P=0.011. Based on the linear regression method, participants' age had a statistically significant impact on ECD in the peripheral cornea (Table 10).

Table 10. Various predictors impact on endothelial parameters in hard contact lens (PMMA/RGP) group.

Parameters Predictors P
Central-endothelial cell density Material 0.078
Duration of wear 0.040
Age 0.016
Central-polymegethism Material 0.934
Duration of wear 0.734
Age 0.308
Central-pleomorphism Material 0.642
Duration of wear 0.157
Age 0.357
Peripheral-endothelial cell density Material 0.016
Duration of wear 0.010
Age 0.001
Peripheral-polymegethism Material 0.254
Duration of wear 0.617
Age 0.177
Peripheral-pleomorphism Material 0.442
Duration of wear 0.101
Age 0.892

DISCUSSION

HCL group had a higher pleomorphism and polymegethism than other groups. Many of the studies published so far point out both CV and HEX changes in wearing contact lenses[9][10]. In 2001, Lee et al[11] wrote about the difference in the variation of cells size between those, who did not wear contact lenses, and those, who had a history of wearing lenses for at least 10y (respectively 22%-29% and 26%-33%). HEX percentage reduction was from 59.4%-71% in those not wearing lenses and up to 47.5%-70% when wearing lenses for a minimum of ten years[11]. In wearing contact lenses, a more significant variation of the parameters from the norm correlates with the corneal hypoxia[12]. Possibly, analogical changes were not discovered in SCL group because of lenses' higher oxygen permeability. It is important to note that in HCL group the average of patients' age was higher than in other groups. Different authors have contradicting opinions about the impact of age on pleomorphism and polymegethism. Some of them state that the age has no influence on rates, while others claim that they increase with age[12][14]. Some authors state that the expression of pleomorphism takes time and it is not such a change of endothelium that can be quickly revealed, yet it is a highly sensitive marker of the endothelial damage and instability[12]. Neither change of CV, nor of HEX causes corneal decompensation or clinical expression. Meanwhile, CV increase and HEX decrease are related to the subsequent reduction of ECD and are considered to be its precursors[12].

In HCL group, ECD statistically significantly did not differ from SCL and CG and its mean was not lower in this age group than the one mentioned in literature[15][21]. This does not interfere with research describing ECD when wearing contact lenses and it is explained by the fact that reduction of endotheliocytes, unlike pleomorphism and polymegethism, it is not an early reaction to stress (mainly hypoxia and hypercapnia[22][23]), but is a late outcome of wearing lens for a long time[12] or does not appear at all after wearing gas permeable lenses[24]. ECD decrease with aging, indicated by many sources[13],[19],[25], was observed only in HCL and CG when measuring endotheliocytes in the corneal periphery. Although it is claimed that the morphometric endothelial parameters are the most stable at the age of 15-50y[11], ECD decrease in SCL group did not show up possibly due to the group very homogenous in age (standard deviation was only 3.05) while the age of participants was more varied in HCL and CG groups.

In HCL and CG, ECD in the central cornea was lower than in the periphery. This is likely to be associated with homogenous age of participants in SCL group. It is assumed that the cause of higher density in the endothelial periphery can be the lack of space for endotheliocytes growth[26].

The corneal pachymetry performed in our investigation showed thinner corneas than the means presented in the research carried out in 2013 in which the Lithuanian population with equal age was examined[14]. Small errors are possible due to different methods of measurement.

Corneal thickness did not have any impact to the endothelial morphometric parameters. There are some studies that find no relation between CCT and ECD[26]. Others claim that thinner corneas have lower ECD[20],[27]. It is found that the cornea decompensates and its oedema develops when critical reduction (400-500 cells/mm[2]) of ECD is reached[26].

Smoking did not have any influence on the endothelial parameters, though it was observed that longer duration of smoking causes endothelial thinning. It is confirmed in Sayin et al[28] research which was performed in 2014.

In SCL group duration of lenses wear and permeability of oxygen did not influence any of the endothelial parameters. The possible impact of duration of wear was not observed due to short time (average 5y). Most sources state that more stable endothelial changes are observed when lenses are worn for at least 6y[11], although there are those who claim that 25y are required[12]. Permeability of oxygen had no impact most likely due to highly oxygen permeable contact lenses. After reaching permeability of oxygen of at least 200, open eye oxygenation is the same as without contact lenses[29]. This is why literature states that the contemporary materials of contact lenses solve hypoxia[24],[30][31]. However, it is admitted that the endothelial changes depend not only on hypoxia, but also on hypercapnia[22][23]. Therefore, the future works for the manufacturers of lenses will be targeted not only at increase of Dk/t, but also at reduction of hypercapnia.

The evaluation ofthe impact of HCL materials on the corneal endothelium was impossible in this research because of a small sample of patients. Also, the majority of those who wore not oxygen permeable PMMA lenses at first, after some time changed them to oxygen permeable lenses. Although there were no significant differences inside this group, there was evident CV increase and HEX decrease in HCL group as compared to SCL and CG.

Acknowledgments

The authors would like to thank Idalija Baltruniene MD for referring patients for examination.

Conflicts of Interest: Galgauskas S, None; Ignataviciute J, None; Vieversyte Z, None; Asoklis R, None.

REFERENCES

  • 1.Patel SP, Bourne WM. Corneal endothelial cell proliferation: a function of cell density. Invest Ophtalmol Vis Sci. 2009;50(6):2742–2746. doi: 10.1167/iovs.08-3002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Kheirkhah A, Saboo US, Abud TB, Dohlman TH, Arnoldner MA, Hamrah P, Dana R. Reduced corneal endothelial cell density in patients with dry eye disease. Am J Ophthalmol. 2015;159(6):1022–1026.e2. doi: 10.1016/j.ajo.2015.03.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Kinoshita S, Amanao S, Inoue Y, Ohashi Y, Takahashi H, Tsubota K, Nishida K. Grading for corneal endothelial damage. Nippon Ganka Gakkai Zasshi. 2014;118(2):81–83. [PubMed] [Google Scholar]
  • 4.Wiffen SJ, Hodge DO, Bourne WN. The effect of contact lens wear on the central and peripheral corneal endothelium. Cornea. 2000;19(1):47–51. doi: 10.1097/00003226-200001000-00010. [DOI] [PubMed] [Google Scholar]
  • 5.Zheng T, Le Q, Hong J, Xu J. Comparison of human corneal cell density by age and corneal location: an in vivo confocal microscopy study. BMC Ophthalmol. 2016;16:109. doi: 10.1186/s12886-016-0290-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Choi SO, Jeon HS, Hyon JY, Oh YJ, Wee WR, Chung TY, Shin YJ, Kim JW. Recovery of corneal endothelial cells from periphery after injury. PLoS One. 2015;10(9):e0138076. doi: 10.1371/journal.pone.0138076. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Mimura T, Joyce NC. Replication completence and senescence in central and peripheral human corneal endothelium. Invest Ophthalmol Vis Sci. 2006;47(4):1387–1396. doi: 10.1167/iovs.05-1199. [DOI] [PubMed] [Google Scholar]
  • 8.Amann J, Holley GP, Lee SB, Edelhauser HF. Increased endothelial cell density in the paracentral and peripheral regions of the human cornea. Am J Ophthalmol. 2003;135(5):584–590. doi: 10.1016/s0002-9394(02)02237-7. [DOI] [PubMed] [Google Scholar]
  • 9.Chang SW, Hu FR, Lin LL. Effects of contact lenses on corneal endothelium-a morphological and functional study. Ophthalmologica. 2001;215(3):197–203. doi: 10.1159/000050858. [DOI] [PubMed] [Google Scholar]
  • 10.Carlson KH, Bourne WM, Brubaker RF. Effect of long-term contact lens wear on corneal endothelial cell morphology and function. Invest Ophthalmol Vis Sci. 1988;29(2):185–193. [PubMed] [Google Scholar]
  • 11.Lee JS, Park WS, Lee SH, Oum BS, Cho BM. A comparative study of corneal endothelial changes induced by different durations of soft contact lens wear. Graefes Arch Clin Exp Ophthalmol. 2001;239(1):1–4. doi: 10.1007/s004170000223. [DOI] [PubMed] [Google Scholar]
  • 12.Liesegang TJ. Physiologic changes of the cornea with contact lens wear. CLAO J. 2002;28(1):12–27. [PubMed] [Google Scholar]
  • 13.Gambato C, Longhin E, Catania AG, Lazzarini D, Parrozzani R, Midena E. Aging and corneal layers: an in vivo corneal confocal microscopy study. Graefes Arch Clin Exp Ophthalmol. 2015;253(2):267–275. doi: 10.1007/s00417-014-2812-2. [DOI] [PubMed] [Google Scholar]
  • 14.Galgauskas S, Norvydaitė D, Krasauskaitė D, Stech S, Ašoklis RS. Age-related changes in corneal thickness and endothelial characteristics. Clinical Interventions in Aging. 2013;8:1445–1450. doi: 10.2147/CIA.S51693. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.McCarey BE, Edelhauser HF, Lynn MJ. Review of corneal endothelial specular microscopy for FDA clinical trials of refractive procedures, surgical devices and new intraocular drugs and solutions. Cornea. 2008;27(1):1–16. doi: 10.1097/ICO.0b013e31815892da. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Zavala J, López Jaime GR, Rodríguez Barrientos CA, Valdez-Garcia J. Corneal endothelium developmental strategies for regeneration. Eye. 2013;27(5):579–588. doi: 10.1038/eye.2013.15. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Doughty MJ. A prospective analysis of corneal endothelial polymegethism and cell density in young adult Asian. Clin Exp Optom. 2014;97(3):256–263. doi: 10.1111/cxo.12127. [DOI] [PubMed] [Google Scholar]
  • 18.Mohammad-Salih PA. Corneal endothelial cell density and morphology in normal Malay eyes. Med J Malaysia. 2011;66(4):300–303. [PubMed] [Google Scholar]
  • 19.Higa A, Sakai H, Sawaguchi S, Iwase A, Tomidokoro A, Amano S, Araie M. Corneal endothelial cell density and associated factors in a population-based study in Japan: the Kumejima study. Am J Ophthalmol. 2010;149(5):794–799. doi: 10.1016/j.ajo.2009.12.029. [DOI] [PubMed] [Google Scholar]
  • 20.Patel HY, Patel DV, McGhee CN. Identifying relationships between tomography-derived corneal thickness, curvature, and diameter and in vivo confocal microscopic assessment of the endothelium in healthy corneas of young adults. Eye (Lond) 2009;23(2):270–278. doi: 10.1038/sj.eye.6703091. [DOI] [PubMed] [Google Scholar]
  • 21.Tanaka H, Okumura N, Koizumi N, Sotozono C, Sumii Y, Kinoshita S. Panoramic view of human corneal endothelial cell layer observed by a prototype slit-scaning wide-field contact specular microscope. Br J Ophthalmol. 2017;101(5):655–659. doi: 10.1136/bjophthalmol-2016-308893. [DOI] [PubMed] [Google Scholar]
  • 22.Leung BK, Bonanno JA, Radke CJ. Oxygen-deficient metabolism and corneal edema. Prog Retin Eye. 2011;30(6):471–492. doi: 10.1016/j.preteyeres.2011.07.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Chhabra M, Prausnitz JM, Radke CJ. Modeling corneal metabolism and oxygen transport during contact lens wear. Optom Vis Sci. 2009;86(5):454–466. doi: 10.1097/OPX.0b013e31819f9e70. [DOI] [PubMed] [Google Scholar]
  • 24.Bourne WM. The effect of long-term contact lens wear on the cells of the cornea. CLAO J. 2001;27(4):225–230. [PubMed] [Google Scholar]
  • 25.Niederer RL, Perumal D, Sherwin T, McGhee CN. Age-related differences in the normal human cornea: a laser scanning in vivo confocal microscopy study. Br J Ophthalmol. 2007;91(9):1165–1169. doi: 10.1136/bjo.2006.112656. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Wörner CH, Olguín A, Ruíz-García JL, Garzón-Jiménez N. Cell patern in adult human corneal endothelium. PLoS One. 2011;6(5):e19483. doi: 10.1371/journal.pone.0019483. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Müller A, Craig JP, Grupcheva CN. The effects of corneal parameters on the assessment of endothelial cell density in the elderly eye. Br J Ophthalmol. 2004;88(3):325–330. doi: 10.1136/bjo.2003.019315. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Sayin N, Kara N, Pekel G, Altinkaynak H. Effects of chronic smoking on central corneal thickness, endothelial cell, and dry eye parameters. Cutan Ocul Toxicol. 2014;33(3):201–205. doi: 10.3109/15569527.2013.832688. [DOI] [PubMed] [Google Scholar]
  • 29.Papas EB. The significance of oxygen during contact lens wear. Contact Lens Anterior Eye. 2014;37(6):394–404. doi: 10.1016/j.clae.2014.07.012. [DOI] [PubMed] [Google Scholar]
  • 30.Sweeney DF. Have silicone hydrogel lenses eliminated hypoxia? Eye Contact Lens. 2013;39(1):53–60. doi: 10.1097/ICL.0b013e31827c7899. [DOI] [PubMed] [Google Scholar]
  • 31.Nguyen T, Soni PS, Brizendine E, Bonanno JA. Variability in hypoxia-induced corneal swelling is associated with variability in corneal metabolism and endothelial function. Eye Contact Lens. 2003;29(2):117–125. doi: 10.1097/01.ICL.0000062462.73172.18. [DOI] [PubMed] [Google Scholar]