Main text
Oxygenation targets in critically ill patients admitted to the intensive care unit (ICU), in particular in patients with acute hypoxaemic respiratory failure, are still a matter of debate. There is mounting evidence for potential harm through hyperoxia [1–3]. Nevertheless, the optimal oxygenation targets, which minimise hyperoxia while maintaining sufficient oxygenation to avoid harm through hypoxia, remain unclear. Therefore, larger randomised clinical trials on the subject are needed. Several observational studies [4] as well as interventional before-and-after trials [1, 5] and three small randomised controlled trials [2, 3, 6] have added valuable, although not definitive, evidence to the field. Arterial oxygen saturation (SaO2) or pulse oximetry (SpO2) has been the primary parameter defining the target range in most of the interventional studies conducted. We would like to dispute this preference of SaO2 and SpO2 over arterial oxygen tension (PaO2) as the target parameter. Hence, this proposition for debate.
The general hypothesis of the studies on oxygen use in the ICU is that the dangers of oxygen toxicity are underestimated, and that the negative impact of hyperoxia is significant, even when compared to the risks of hypoxia following conservative oxygenation strategies [1, 2, 5, 6]. Hence, studies proposing more conservative oxygenation targets have been conducted primarily in the effort to avoid hyperoxia. The parameters PaO2 and SaO2 are linked as visualised in the oxygen dissociation curve [7]. The interval of PaO2 in ICU patients spans upwards from approximately 7.3 kPa (55 mmHg) [8–10]. In this area, the oxygen dissociation curve is rather flat [7] and covers only a small range of SaO2 values. The SaO2 range becomes even narrower with hyperoxaemic levels of PaO2 depending on its definition, which varies from over 13.3 kPa (100 mmHg) to over 64.9 kPa (487 mmHg) [4], while the corresponding SaO2 encompasses only four numeric values from 97% to 100%. This limits the control of hyperoxaemia if SaO2 is used as the target parameter of oxygenation. Furthermore, when SaO2 defines the oxygenation target in clinical trials, the narrow SaO2 spectrum will likely result in a larger risk of an overlap of PaO2 or SaO2 between the conventional and interventional study groups.
One could argue that the use of SaO2 over PaO2 offers the possibility to use the non-invasive measurement of oxygenation, SpO2. The correlation between SaO2 and SpO2 is generally high which makes SpO2 invaluable in the continuous monitoring and titration of oxygen supplementation in the ICU [11]. Nevertheless, SpO2 is unreliable as a measure of arterial oxygenation in patients with sepsis [12], in patients with use of vasopressors [13], in patients with high or low body temperature [11], and in patients with hypoxaemia [12, 13]. Therefore, SpO2 cannot be used in the ICU without intermittent measurements of SaO2 for comparison as remarkable differences above 4.4 percentage points [11] may occur. Furthermore, SpO2 has been shown inadequate in identifying and in quantifying hyperoxaemia defined as PaO2 above 16.7 kPa (125 mmHg) at SpO2 levels above 96% [14]. Thus, targeting normoxaemic oxygenation levels in the upper part of the normal reference interval by using SpO2 would inarguably lead to episodes of definitive hyperoxaemia. Moreover, at the steep slope of the oxygen dissociation curve [7], where the differentiation in SaO2 is the highest, SpO2 is also inadequate in correctly identifying the oxygenation level in the ICU as SpO2 above 94% is necessary to avoid a risk of having SaO2 below 90% [13]. This fact further narrows the spectrum of differentiation when using SpO2.
An argument for using SaO2 over PaO2 is that under normal, healthy conditions more than 98% of the transported oxygen is bound to haemoglobin [7]. Therefore, SaO2 in combination with the haematocrit or haemoglobin level represents the most direct parameter for expressing the amounts of oxygen actually carried in the arterial blood whereas PaO2 is only a secondarily derived parameter. However, the oxygen dissociation curve [7] shows that SaO2 and PaO2 are mutually dependent, and so this point remains essentially theoretical. Additionally, with increasing hyperoxaemia SaO2 loses its value due to the rigid ceiling of SaO2 at 100%. Furthermore, since the formation of reactive oxygen species is closely linked to the free amounts of oxygen [15] and since the reactive oxygen species contribute importantly to the detrimental effects of hyperoxia [15], PaO2 is probably the parameter with the tightest relationship to the toxic properties of oxygen. As these toxic properties are what trials on the subject strive to minimise, one could claim that this connection is just as important as the link between SaO2 and the total oxygen content of the blood.
In clinical practice, both SaO2 and PaO2 are commonly used to guide oxygen therapy, particularly in the ICU setting, as the majority of acute critically ill ICU patients require arterial cannulation for haemodynamic monitoring. For evaluating arterial oxygenation, a recent survey of northern European ICU physicians has shown that PaO2 was preferred to SaO2 [16].
In summary, to define the oxygenation target levels precisely, to reduce the risk of unwanted hyperoxaemia, and to minimise overlap between conventional and interventional groups, in clinical trials of higher versus lower oxygenation targets in the ICU population, PaO2 is in our opinion the superior target parameter as compared to SaO2. This is also reflected in clinicians’ self-reported preferences. Therefore, we advocate the use of PaO2 as the primary target parameter of arterial oxygenation in future clinical trials that aim to establish the evidence of how to use medical oxygen in patients admitted to the ICU.
Acknowledgements
Not applicable.
Funding
OLS’ PhD project is funded by a grant from Innovation Fund Denmark.
Availability of data and materials
Not applicable.
Abbreviations
- HOT-ICU
Handling Oxygenation Targets in the Intensive Care Unit
- ICU
Intensive care unit
- PaO2
Arterial oxygen tension
- SaO2
Arterial oxygen saturation
- SpO2
Pulse oximetry
Authors’ contributions
BSR conceived the idea for the editorial. OLS drafted the primary manuscript. OLS and BSR revised the manuscript together. Both authors have read and approved the final manuscript.
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
Both authors are involved in an ongoing investigator-initiated randomised trial targeting oxygenation in acutely ill patients in the ICU, the Handling Oxygenation Targets in the Intensive Care Unit (HOT-ICU) trial (ClinicalTrials.gov NCT03174002), OLS as coordinating investigator and BSR as sponsor and primary investigator.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Olav Lilleholt Schjørring, Email: o.schjoerring@rn.dk.
Bodil Steen Rasmussen, Email: bodil.steen.rasmussen@rn.dk.
References
- 1.Helmerhorst HJ, Schultz MJ, van der Voort PH, Bosman RJ, Juffermans NP, de Wilde RB, et al. Effectiveness and clinical outcomes of a two-step implementation of conservative oxygenation targets in critically ill patients: a before and after trial. Crit Care Med. 2016;44(3):554–563. doi: 10.1097/CCM.0000000000001461. [DOI] [PubMed] [Google Scholar]
- 2.Girardis M, Busani S, Damiani E, Donati A, Rinaldi L, Marudi A, et al. Effect of conservative vs conventional oxygen therapy on mortality among patients in an intensive care unit: the Oxygen-ICU Randomized Clinical Trial. JAMA. 2016;15:1583–1589. doi: 10.1001/jama.2016.11993. [DOI] [PubMed] [Google Scholar]
- 3.Asfar P, Schortgen F, Boisrame-Helms J, Charpentier J, Guerot E, Megarbane B, Grimaldi D, et al. Hyperoxia and hypertonic saline in patients with septic shock (HYPERS2S): a two-by-two factorial, multicentre, randomised, clinical trial. Lancet Respir Med. 2017;5(3):180–190. doi: 10.1016/S2213-2600(17)30046-2. [DOI] [PubMed] [Google Scholar]
- 4.Damiani E, Adrario E, Girardis M, Romano R, Pelaia P, Singer M, et al. Arterial hyperoxia and mortality in critically ill patients: a systematic review and meta-analysis. Crit Care. 2014;18(6):711. doi: 10.1186/s13054-014-0711-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Suzuki S, Eastwood GM, Glassford NJ, Peck L, Young H, Garcia-Alvarez M, et al. Conservative oxygen therapy in mechanically ventilated patients: a pilot before-and-after trial. Crit Care Med. 2014;42(6):1414–1422. doi: 10.1097/CCM.0000000000000219. [DOI] [PubMed] [Google Scholar]
- 6.Panwar R, Hardie M, Bellomo R, Barrot L, Eastwood GM, Young PJ, et al. Conservative versus liberal oxygenation targets for mechanically ventilated patients. A pilot multicenter randomized controlled trial. Am J Respir Crit Care Med. 2016;193(1):43–51. doi: 10.1164/rccm.201505-1019OC. [DOI] [PubMed] [Google Scholar]
- 7.Collins JA, Rudenski A, Gibson J, Howard L, O'Driscoll R. Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve. Breathe (Sheff) 2015;11(3):194–201. doi: 10.1183/20734735.001415. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.The Acute Respiratory Distress Syndrome Network Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network. N Engl J Med. 2000;342(18):1301–1308. doi: 10.1056/NEJM200005043421801. [DOI] [PubMed] [Google Scholar]
- 9.de Jonge E, Peelen L, Keijzers PJ, Joore H, de Lange D, van der Voort PH, et al. Association between administered oxygen, arterial partial oxygen pressure and mortality in mechanically ventilated intensive care unit patients. Crit Care. 2008;12(6):R156. doi: 10.1186/cc7150. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Zhang Z, Ji X. Quadratic function between arterial partial oxygen pressure and mortality risk in sepsis patients: an interaction with simplified acute physiology score. Sci Rep. 2016;6:35133. doi: 10.1038/srep35133. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Ebmeier SJ, Barker M, Bacon M, Beasley RC, Bellomo R, Knee Chong C, et al. A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients. Anaesth Intensive Care. 2018;46(3):297–303. doi: 10.1177/0310057X1804600307. [DOI] [PubMed] [Google Scholar]
- 12.Wilson BJ, Cowan HJ, Lord JA, Zuege DJ, Zygun DA. The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study. BMC Emerg Med. 2010;10:9-227X-10-9. doi: 10.1186/1471-227X-10-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Van de Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P, Lemaire F, et al. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med. 2001;27(10):1606–1613. doi: 10.1007/s001340101064. [DOI] [PubMed] [Google Scholar]
- 14.Durlinger EMJ, Spoelstra-de Man AME, Smit B, de Grooth HJ, Girbes ARJ, Oudemans-van Straaten HM, et al. Hyperoxia: at what level of SpO2 is a patient safe? A study in mechanically ventilated ICU patients. J Crit Care. 2017;39:199–204. doi: 10.1016/j.jcrc.2017.02.031. [DOI] [PubMed] [Google Scholar]
- 15.Helmerhorst HJ, Schultz MJ, van der Voort PH, de Jonge E, van Westerloo DJ. Bench-to-bedside review: the effects of hyperoxia during critical illness. Crit Care. 2015;19:284. doi: 10.1186/s13054-015-0996-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Schjørring OL, Toft-Petersen AP, Kusk KH, Mouncey P, Sorensen EE, Berezowicz P, et al. Intensive care doctors’ preferences for arterial oxygen tension levels in mechanically ventilated patients. Acta Anaesthesiol Scand. 2018;62(10):1443–1451. doi: 10.1111/aas.13171. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not applicable.