Abstract
The aim of this study was the calculation of conversion coefficients for absorbed doses per fluence (DT/Φ) using the sitting and standing male hybrid phantom (UFH/NCI) exposure to monoenergetic protons with energy ranging from 2 MeV to 10 GeV. Sex-averaged effective dose per fluence (E/Φ) using the results of DT/Φ for the male and female hybrid phantom in standing and sitting postures were also calculated. Results of E/Φ of UFH/NCI standing phantom were also compared with tabulated effective dose conversion coefficients provided in ICRP publication 116. To develop an exposure scenario implementing the male UFH/NCI phantom in sitting and standing postures was used the radiation transport code MCNPX. Whole-body irradiations were performed using the recommended irradiation geometries by ICRP publication 116 antero-posterior (AP), postero-anterior (PA), right and left lateral, rotational (ROT) and isotropic (ISO). In most organs, the conversion coefficients DT/Φ were similar for both postures. However, relative differences were significant for organs located in the lower abdominal region, such as prostate, testes and urinary bladder, especially in the AP geometry. Results of effective dose conversion coefficients were 18% higher in the standing posture of the UFH/NCI phantom, especially below 100 MeV in AP and PA. In lateral geometry, the conversion coefficients values below 20 MeV were 16% higher in the sitting posture. In ROT geometry, the differences were below 10%, for almost all energies. In ISO geometry, the differences in E/Φ were negligible. The results of E/Φ of UFH/NCI phantom were in general below the results of the conversion coefficients provided in ICRP publication 116.
INTRODUCTION
The Monte Carlo technique coupled with computational phantoms is a powerful tool that allows the estimation of organ dose conversion coefficients. Conversion coefficients relate protection with physical quantities; for example, effective dose per fluence or absorbed dose per air kerma(1). These coefficients are useful to estimate doses from occupational exposures since protection quantities ‘equivalent dose’ and ‘effective dose’ are not measurable(1). Several authors have calculated fluence-to-dose conversion coefficients for protons using stylized (mathematical and voxel) phantoms in the standing posture(2–5). There are few studies in the literature that attempt to calculate doses in computational phantom in the sitting posture, but even in these studies only photon, electron or positron doses were calculated(6–11). In a previous paper, organ dose conversion coefficients for protons were calculated using the sitting and standing female hybrid phantom and the influence of the posture in absorbed dose was discussed(12). It turns out that changing the posture of the computational phantom may contribute to differences in absorbed dose in organs and tissues and, depending on the irradiation scenario, phantoms with variable stature in standing or sitting configurations can be used to contribute to reducing the uncertainties(6, 12). To better represent these posture differences, this study presents adult male hybrid anthropomorphic phantoms, in both standing and sitting positions, for calculation of organ and effective dose conversion coefficients. Hybrid anthropomorphic phantom are representation of the human body developed using tomographic images like voxel phantoms but adjusted using a 3D modeling software to better represent organ, tissues and external contours of a real person. First the phantom is polygonized then internal organs are modeled to match reference organ volume and smooth contours via polygon mesh and NURBS (nonuniform rational B-spline) surface and afterward the phantom is voxelized(12–14).
Protons contribute to doses delivered to passenger and aircraft crew members, especially at aircraft cruising altitudes, because the Earth is continually bombarded by galactic cosmic radiation (GCR) that is formed almost 98% by nuclei in which 88% of these nuclei are protons(15). GCR can have energies up to 1011 GeV, but the most frequent energy distribution is at a few hundred MeV to 1 GeV per nucleon(16). When the GCR and the plasma of protons and electrons coming from the sun interact with the earth atmosphere, nuclear reactions occur producing secondary radiation, which together with primary incident particles lead to radiation exposure that decreases in intensity with decreasing altitude(15–18). In atmospheric region, the geometrical condition that closely represents the aircrew exposure to cosmic radiation field is usually assumed to be the isotropic (ISO) geometry(19, 20). Other idealized irradiation geometries such as antero-posterior (AP), postero-anterior (PA), right and left lateral (RLAT and LLAT) and rotational (ROT) may be taken as approximations to actual conditions of exposure. AP, PA and lateral geometries are considered to approximate a scenario in which single sources are at large distance from the body surface. ROT geometry approximates, for example, a scenario that a person is irradiated from a widely dispersed planar source(1).
The aims of this study were calculate absorbed dose conversion coefficients for protons using the standing and sitting adult male hybrid phantom and effective dose conversion coefficients using male and female hybrid phantom (UFH/NCI)(14, 21) for exposure to monoenergetic protons in AP, PA, RLAT, LLAT, ROT and ISO geometries. The conversion factors from different postures were compared to each other. Sex-averaged effective dose conversion coefficients(22) were obtained from the results of the absorbed dose conversion coefficients for the male phantom calculated in this study and the results for the female hybrid phantom presented in a previous paper(12). Results of effective dose conversion coefficients of UFH/NCI standing phantom were also compared with tabulated effective dose conversion coefficients provided in ICRP publication 116(1) concerning external irradiation beam of protons using the reference phantom of the ICRP publication 110(23).
MATERIALS AND METHODS
MCNPX code (version 2.7.0)(24) was used to simulate irradiation geometries and calculate fluence-to-dose conversion coefficients for the UFH/NCI adult male hybrid phantom in sitting and standing posture (Figure 1). A source of monoenergetic protons was used to expose the phantom placed in vacuum from 2 MeV to 10 GeV in six irradiation geometries (AP, PA, RLAT, LLAT, ROT and ISO) as described in ICRP publication 116(1). The source plane respectively for the standing and sitting phantom has 58.2 × 175.8 cm2 and 54 × 135.3 cm2, in AP and PA geometries, 31.2 × 175.8 cm2 and 79.2 × 135.3 cm2, in lateral geometries. In the ROT geometry, the phantoms are within a cylindrical source of 178.8 cm height and 33.35 cm radius, for the standing posture, and 135.3 cm height and 48.41 cm radius, for the sitting posture. In the ISO geometry the source is a sphere of 94.84 cm radius, for the standing phantom, and 83.74 cm radius, for the sitting phantom. Secondary particles (neutrons, photons, protons etc) generated when protons interact with matter were also transported by the Monte Carlo code. No transport of electron delta rays from direct protons interactions are done by MCNPX code, instead the electron energy is locally absorbed. The transport energy cutoff for protons and secondary particles were set to 10 GeV in the upper energy limit and the default values of low energy cutoff presented in the MCNPX code, except neutrons that was set to 1.10−9 MeV. The total histories were 108 for each simulation resulting in a calculation time between 3 and 50 hours, respectively for 2 MeV and 10 GeV of source energy. One billion histories (109) were simulated from 10 to 30 MeV in AP, PA and lateral geometries and from 10 to 50 MeV in ROT and ISO geometries. More details about the sitting hybrid phantom can be found in our previous paper and in Han et al.(12, 25). Details of the UFH/NCI adult male phantom can be found in Lee et al.(21). Red bone marrow (RBM) and endosteum are defined in sophisticated spongiosa and medullary cavity structures in the UFH/NCI male phantom. Therefore, the absorbed dose in RBM and endosteum was determined by averaging the absorbed dose in each spongiosa and medullary cavity, which contain RBM and endosteum tissue, multiplied with the mass ratios of RBM and endosteum contained in each region, as recommended in ICRP publication 116(1). Energy deposited by all particles transported in the simulations was normalized by incident proton fluence to derive organ dose conversion coefficients (pGy cm2). Organ dose conversion coefficients (DT/Φ) of the standing and sitting UFH/NCI adult male phantoms were compared to each other. Effective dose conversion coefficients (E/Φ) were calculated using the sex-average equivalent doses obtained from the average of equivalent dose of male and female phantoms, as recommended in ICRP publication 103(22). E/Φ was obtained for the sitting and standing phantom posture and results were compared to each other and with the results presented in ICRP publication 116 using the ICRP reference phantoms(23).
RESULTS AND DISCUSSION
Calculated fluence-to-absorbed dose conversion coefficients in units of pGy cm2 are provided in electronic format in Tables A1–A6 for the 27 organs of the standing and sitting UFH/NCI male phantom. As presented in these tables, statistical uncertainties for most organs irradiated in AP, PA, RLAT, LLAT, ROT and ISO geometry were <10% considering 108 particle histories in each simulation. Statistical uncertainties were ~10% for smallest and/or deeper organs (such as adrenals, gall bladder and prostate) since fewer numbers of particles interact in these organs in low energy proton range (<50 MeV). In order to obtain uncertainties below 10% in these deeper and smaller organs it was simulated 109 particle histories. Statistical uncertainties were very low in skin, RBM, bone surface and muscle for almost all proton energies studied since the region between these tissue and protons is large.
Relative differences between fluence-to-dose conversion coefficients in standing and sitting posture for all irradiation geometries are also presented in Tables A1–A6. It was observed differences <10% for some organs and tissues.
In AP geometry the highest differences occurred for organ and tissues located in the pelvic and lower abdominal region, such as testes, urinary bladder, prostate, colon and small intestine. In energy below 150 MeV, conversion coefficients in the standing posture were higher than in the sitting posture and from 150 MeV it was observed the opposite (Figure 2). This occurred because the upper legs of the phantom in the sitting posture contribute to reduce proton energy in low energy range, while in high energy range the upper legs contribute to increase the forward scattering that deliver more dose in organs in the bottom of the trunk region. Similar results were observed in organ located at the abdominal region (adrenals, kidneys, pancreas, spleen and gall bladder) in which the arms and hands are located in front of the phantom in the sitting posture, while in the standing posture these structures are positioned to the trunk side (Figure 1). In AP and PA geometry, differences observed in skin, muscle and endosteum were due to the region of interaction between incident protons and these tissues, which is much higher in the standing posture as can be seen in Figure 3. In this study skin dose coefficient refers to dose averaged over the whole skin of the phantom. However below 50 MeV, conversion coefficients in muscle and endosteum were higher in the sitting posture than in the standing posture in AP geometry (Figure 3). In this case, arms and hands are rotated 90° between standing and sitting postures (Figure 1), so muscle and bones of all fingers are irradiated unshielded in the sitting posture, while in the standing posture the fingers shield each other. Conversion coefficients in RBM were higher in the standing posture between 100 and 200 MeV mainly because the upper legs position. The interaction between proton beam and the RBM inside the femur contribute more to the dose in the standing than in the sitting posture. In PA geometry, differences in RBM were <5% in all energy studied (Figure 3) mainly because the bone sites that contain higher amount of RBM are at the back of the phantom(12). Conversion coefficients in testes were much higher in the sitting than in the standing posture in PA geometry, differently to the result of AP geometry. In this case, proton energy was decreased by the structures around the testes in the standing phantom resulting in a lower organ dose in this posture. In prostate, small intestine and urinary bladder, conversion coefficients were higher in the standing posture, but the differences are smaller compared to the same organs in AP irradiation.
In right and left lateral irradiation geometry were observed similar results. For example, in skin, muscle, endosteum and RBM the conversion coefficients were slightly higher in the sitting posture (Figure 4). Skin and muscle presented in arms and hands contribute to increase the absorbed dose in these tissues, because these structures are positioned in a way that the region of interaction with proton beam is higher in the sitting posture than in the standing posture. Organs and tissues located in chest and abdominal region like adrenals, colon, gall bladder, stomach, urinary bladder, prostate, kidneys, liver, pancreas, small intestine, spleen and lungs presented conversion coefficients in the sitting posture greater than in standing posture (Figure 5). In this case arms and hands structures contribute to reduce the energies of protons that irradiate the phantom laterally. In contrast, conversion coefficients in breast (Figure 5) and thymus were higher in the standing posture due to the structures of upper arms (Figure 1).
In ROT and ISO geometry, fluence-to-skin dose coefficients were very similar in both postures, in which <10% of relative differences were observed (Figure 6). Other organs presented different conversion coefficients for standing and sitting phantom due to the difference in position of arms, hands and upper legs which contribute to reduce the protons energy or enhance the region of interaction between protons and tissues. For example, conversion coefficient in breast was higher in the standing posture in 50 MeV and 100 MeV in ISO geometry (Figure 6) because the thighs of the sitting phantom contribute to reduce the protons energy in upward irradiation while in other direction there is no difference in breast irradiation.
Effective dose coefficients were also calculated for both posture from sex-averaged organ dose coefficients of UFH/NCI male (given in this study) and female phantom(12). These coefficients are presented in Table 1 for all irradiation geometry (AP, PA, RLAT, LLAT, ROT and ISO) as well as relative differences between effective dose coefficients of sitting and standing phantom. In AP and PA geometry were observed differences >5% in E/Φ between standing and sitting phantom from 2 to 100 MeV. Below 30 MeV, conversion coefficients in standing phantom were around 18% higher than in the sitting phantom. Absorbed dose conversion coefficient in skin contributes to the effective dose coefficients estimation much more than other organ and tissues in energies below 100 MeV, and as discussed above and in a previous paper(12) the skin dose conversion coefficients were higher in the standing phantom than in the sitting phantom. Although breast-dose conversion coefficients between 30 and 100 MeV in AP geometry contribute more to effective dose estimation than skin-dose conversion coefficients, differences between standing and sitting conversion coefficients in breast were minimal. Above 100 MeV, relative differences in conversion coefficients between standing and sitting phantom were <5% in AP geometry and negligible in PA geometry. Results of E/Φ in RLAT and LLAT geometry were very similar. Until 20 MeV of energy, conversion coefficients in sitting phantom were higher than in standing phantom due to the same reason presented previously for the AP and PA geometry, but in lateral geometries skin dose was much higher in the sitting than in the standing phantom as discussed earlier. However, breast-dose conversion coefficients were higher in standing than in sitting male phantom in 30 MeV and 50 MeV; therefore, effective dose coefficients were also higher in the standing phantom in these energies. In 100 MeV and 150 MeV, conversion coefficients in the sitting posture were around 20% higher than in the standing posture due to the contribution of testes and abdominal organs conversion coefficients to effective dose. In ISO geometry, effective dose coefficients were very similar in sitting and standing posture. Exceptions were in energies between 20 and 100 MeV, in which conversion coefficients were higher in standing posture than in sitting posture, but even then differences were <10% (Table 1). In ROT geometry, until 100 MeV, conversion coefficients were higher in standing posture than in sitting posture, and above 100 MeV it was observed the opposite. However, except in 30 MeV and 50 MeV, all differences were around or <5%. This result is due the minimal differences observed in skin-dose coefficients below 30 MeV. Above 30 MeV of energy, differences in testes, urinary bladder, prostate and muscle are significant.
Table 1.
Proton energy (MeV) | Sitting phantom | Standing phantom | Relative difference (RD) (%) | ||
---|---|---|---|---|---|
E/Φ (pSv.cm²) | Relative error (%) | E/Φ (pSv.cm²) | Relative error (%) | ||
AP | |||||
2 | 5.63 | 0.01 | 6.83 | 0.01 | −18 |
5 | 14.05 | 0.01 | 17.06 | 0.01 | −18 |
10 | 28.04 | 0.01 | 34.04 | 0.01 | −18 |
20 | 110 | 0.2 | 120 | 0.2 | −8 |
30 | 523 | 0.1 | 550 | 0.2 | −5 |
50 | 973 | 0.09 | 1035 | 0.1 | −6 |
100 | 2056 | 0.04 | 2198 | 0.04 | −7 |
150 | 2291 | 0.04 | 2354 | 0.04 | −3 |
200 | 1789 | 0.04 | 1841 | 0.04 | −3 |
500 | 1165 | 0.05 | 1133 | 0.05 | 3 |
1000 | 1103 | 0.06 | 1071 | 0.07 | 3 |
2000 | 1100 | 0.08 | 1072 | 0.09 | 3 |
5000 | 1248 | 0.09 | 1212 | 0.1 | 3 |
10 000 | 1478 | 0.1 | 1439 | 0.1 | 3 |
PA | |||||
2 | 5.64 | 0.01 | 6.84 | 0.01 | −18 |
5 | 14.07 | 0.01 | 17.08 | 0.01 | −18 |
10 | 28.07 | 0.01 | 34.07 | 0.01 | −18 |
20 | 36.09 | 0.01 | 44.23 | 0.01 | −18 |
30 | 32.53 | 0.02 | 39.49 | 0.02 | −18 |
50 | 75.47 | 0.05 | 81.43 | 0.04 | −7 |
100 | 1074 | 0.04 | 1103 | 0.05 | −3 |
150 | 2565 | 0.04 | 2588 | 0.05 | −1 |
200 | 1928 | 0.04 | 1940 | 0.04 | −1 |
500 | 1179 | 0.05 | 1189 | 0.05 | −1 |
1000 | 1117 | 0.06 | 1128 | 0.07 | −1 |
2000 | 1117 | 0.07 | 1124 | 0.09 | −1 |
5000 | 1252 | 0.08 | 1257 | 0.1 | −0.4 |
10 000 | 1496 | 0.09 | 1501 | 0.1 | −0.4 |
RLAT | |||||
2 | 4.51 | 0.02 | 3.88 | 0.01 | 16 |
5 | 11.26 | 0.02 | 9.67 | 0.01 | 16 |
10 | 22.46 | 0.02 | 19.30 | 0.01 | 16 |
20 | 32.11 | 0.05 | 29.77 | 0.07 | 8 |
30 | 62.0 | 0.3 | 64.2 | 0.2 | −3 |
50 | 275 | 0.2 | 295 | 0.2 | −7 |
100 | 801 | 0.1 | 856 | 0.07 | −6 |
150 | 1592 | 0.08 | 1396 | 0.04 | 14 |
200 | 2013 | 0.07 | 2004 | 0.05 | 0.5 |
500 | 1154 | 0.07 | 1140 | 0.05 | 1 |
1000 | 1099 | 0.08 | 1084 | 0.06 | 1 |
2000 | 1103 | 0.1 | 1089 | 0.07 | 1 |
5000 | 1265 | 0.1 | 1253 | 0.08 | 1 |
10 000 | 1514 | 0.1 | 1499 | 0.09 | 1 |
LLAT | |||||
2 | 4.51 | 0.02 | 3.88 | 0.01 | 16 |
5 | 11.26 | 0.02 | 9.67 | 0.01 | 16 |
10 | 22.47 | 0.02 | 19.30 | 0.01 | 16 |
20 | 32.51 | 0.06 | 31.06 | 0.09 | 5 |
30 | 65.0 | 0.3 | 73.2 | 0.2 | −11 |
50 | 277 | 0.3 | 292 | 0.2 | −5 |
100 | 966 | 0.09 | 800 | 0.07 | 21 |
150 | 1828 | 0.07 | 1427 | 0.04 | 28 |
200 | 2017 | 0.06 | 2072 | 0.05 | −3 |
500 | 1154 | 0.07 | 1142 | 0.05 | 1 |
1000 | 1097 | 0.08 | 1085 | 0.06 | 1 |
2000 | 1100 | 0.1 | 1090 | 0.07 | 1 |
5000 | 1258 | 0.1 | 1254 | 0.08 | 0.3 |
10 000 | 1503 | 0.1 | 1501 | 0.09 | 0.1 |
ROT | |||||
2 | 6.07 | 0.03 | 6.30 | 0.02 | −4 |
5 | 15.03 | 0.04 | 15.60 | 0.03 | −4 |
10 | 29.30 | 0.06 | 30.29 | 0.06 | −3 |
20 | 57.8 | 0.3 | 60.2 | 0.3 | −4 |
30 | 176 | 0.5 | 192 | 0.4 | −8 |
50 | 419 | 0.3 | 482 | 0.3 | −13 |
100 | 1270 | 0.1 | 1357 | 0.1 | −6 |
150 | 2223 | 0.1 | 2139 | 0.1 | 4 |
200 | 2096 | 0.1 | 1988 | 0.09 | 5 |
500 | 1251 | 0.1 | 1184 | 0.1 | 6 |
1000 | 1186 | 0.1 | 1122 | 0.1 | 6 |
2000 | 1189 | 0.2 | 1122 | 0.2 | 6 |
5000 | 1343 | 0.2 | 1274 | 0.2 | 5 |
10 000 | 1606 | 0.2 | 1517 | 0.2 | 6 |
ISO | |||||
2 | 4.85 | 0.02 | 4.83 | 0.02 | 0.5 |
5 | 11.97 | 0.03 | 11.93 | 0.03 | 0.3 |
10 | 23.10 | 0.04 | 23.14 | 0.05 | −0.2 |
20 | 44.05 | 0.2 | 45.8 | 0.2 | −4 |
30 | 138 | 0.3 | 147 | 0.3 | −6 |
50 | 387 | 0.2 | 410 | 0.3 | −6 |
100 | 959 | 0.09 | 1023 | 0.1 | −6 |
150 | 1696 | 0.08 | 1705 | 0.08 | −0.5 |
200 | 1810 | 0.07 | 1823 | 0.08 | −0.7 |
500 | 1157 | 0.07 | 1152 | 0.08 | 0.4 |
1000 | 1099 | 0.09 | 1093 | 0.1 | 0.5 |
2000 | 1104 | 0.1 | 1097 | 0.1 | 1 |
5000 | 1268 | 0.1 | 1263 | 0.1 | 0.5 |
10 000 | 1518 | 0.1 | 1505 | 0.2 | 1 |
Table 2 presents the comparison between results of sex-averaged effective dose coefficients of the UFH/NCI in standing posture and the effective dose coefficients of the reference phantom obtained in ICRP publication 116(1). It was observed large differences in E/Φ between ICRP reference phantom and UFH/NCI phantom, especially in energies below 100 MeV in all geometries studied. As discussed in Alves et al.(12), the mayor contributor to differences in organ dose coefficients and consequently in effective dose coefficients between UFH/NCI and the ICRP reference phantom is the voxel size in which the male and female UFH/NCI phantoms have 3 × 3 × 3 mm3 and the male and female ICRP reference phantom have respectively 2.137 × 2.137 × 8 mm3 and 1.775 × 1.775 × 4.84 mm3. This contribute to differences in skin dose conversion coefficients between ICRP and UFH/NCI phantom, in which below 20 MeV were higher in ICRP phantom than in UFH/NCI phantom, as can be seen in Figure 7. Since effective dose between 2 and 10 MeV is due only to skin dose contribution, then differences in skin dose coefficients explain the differences observed in E/Φ. Although UFH/NCI phantom have no significant differences in organ masses compared to mass reference values in ICRP publication 89(21, 26), structural differences such as organ position and tissue layer also contribute to differences in conversion coefficients on UFH/NCI and ICRP reference phantom. For example, dose coefficients in breast were lower in UFH/NCI phantom in AP, ROT, ISO and lateral geometries below 30 MeV (Figure 7) because there is a layer of adipose tissue around the breasts which reduces the dose. Besides, some parts of the breast in ICRP phantom are exposed direct to the protons because there are lacking some voxels that represent the skin around the breast. These two features explain the differences below 50 MeV between ICRP and UFH/NCI effective dose coefficients. Despite differences, it is interesting that the magnitude of effective dose coefficients on both UFH/NCI and ICRP reference phantom are almost the same in all geometry simulated, especially at energies above 100 MeV where the dose is less dependent of structural variations.
Table 2.
ICRP reference phantom | UFH/NCI phantom | |||
---|---|---|---|---|
Proton energy (MeV) | E/Φ (pSv.cm²) | E/Φ (pSv.cm²) | Relative error (%) | Relative difference (RD) (%) |
AP | ||||
2 | 10.90 | 6.83 | 0.01 | 37 |
5 | 27.30 | 17.06 | 0.01 | 38 |
10 | 54.90 | 34.04 | 0.01 | 38 |
20 | 428 | 200 | 0.2 | 72 |
30 | 750 | 550 | 0.2 | 27 |
50 | 1180.00 | 1035 | 0.1 | 12 |
100 | 2510.00 | 2198 | 0.04 | 12 |
150 | 2380.00 | 2354 | 0.04 | 1 |
200 | 1770.00 | 1841 | 0.04 | −4 |
500 | 1150.00 | 1133 | 0.05 | 1 |
1000 | 1090.00 | 1071 | 0.07 | 2 |
2000 | 1120.00 | 1072 | 0.09 | 4 |
5000 | 1230.00 | 1212 | 0.1 | 2 |
10 000 | 1410.00 | 1439 | 0.1 | −2 |
PA | ||||
2 | 10.90 | 6.84 | 0.01 | 37 |
5 | 27.30 | 17.08 | 0.01 | 37 |
10 | 54.60 | 34.07 | 0.01 | 38 |
20 | 43.60 | 44.23 | 0.01 | −2 |
30 | 36.10 | 39.49 | 0.02 | −9 |
50 | 71.50 | 81.43 | 0.04 | −14 |
100 | 1190.00 | 1103 | 0.05 | 7 |
150 | 2820.00 | 2588 | 0.05 | 8 |
200 | 1930.00 | 1940 | 0.04 | −1 |
500 | 1240.00 | 1189 | 0.05 | 4 |
1000 | 1230.00 | 1128 | 0.07 | 8 |
2000 | 1280.00 | 1124 | 0.09 | 12 |
5000 | 1450.00 | 1257 | 0.1 | 13 |
10 000 | 1740.00 | 1501 | 0.1 | 14 |
RLAT | ||||
2 | 5.62 | 3.88 | 0.01 | 31 |
5 | 14.00 | 9.67 | 0.01 | 31 |
10 | 28.10 | 19.3 | 0.01 | 31 |
20 | 78.80 | 29.77 | 0.07 | 62 |
30 | 172 | 64.2 | 0.2 | 63 |
50 | 372 | 295 | 0.2 | 21 |
100 | 818 | 856 | 0.07 | −5 |
150 | 1460.00 | 1396 | 0.04 | 4 |
200 | 2180.00 | 2004 | 0.05 | 8 |
500 | 1210.00 | 1140 | 0.05 | 6 |
1000 | 1200.00 | 1084 | 0.06 | 10 |
2000 | 1250.00 | 1089 | 0.07 | 13 |
5000 | 1410.00 | 1253 | 0.08 | 11 |
10 000 | 1670.00 | 1499 | 0.09 | 10 |
LLAT | ||||
2 | 5.61 | 3.88 | 0.01 | 31 |
5 | 14.00 | 9.67 | 0.01 | 31 |
10 | 28.10 | 19.3 | 0.01 | 31 |
20 | 82.80 | 31.06 | 0.09 | 63 |
30 | 180 | 73.2 | 0.2 | 59 |
50 | 379 | 292 | 0.2 | 23 |
100 | 994 | 800 | 0.07 | 20 |
150 | 1640.00 | 1427 | 0.04 | 13 |
200 | 2150.00 | 2072 | 0.05 | 4 |
500 | 1210.00 | 1142 | 0.05 | 6 |
1000 | 1180.00 | 1085 | 0.06 | 8 |
2000 | 1250.00 | 1090 | 0.07 | 13 |
5000 | 1390.00 | 1254 | 0.08 | 10 |
10 000 | 1630.00 | 1501 | 0.09 | 8 |
ROT | ||||
2 | 8.98 | 6.3 | 0.02 | 30 |
5 | 22.10 | 15.6 | 0.03 | 29 |
10 | 50.10 | 30.29 | 0.06 | 40 |
20 | 165 | 60.2 | 0.3 | 64 |
30 | 296 | 192 | 0.4 | 35 |
50 | 532 | 4812 | 0.3 | 9 |
100 | 1440.00 | 1357 | 0.1 | 6 |
150 | 2160.00 | 2139 | 0.1 | 1 |
200 | 1960.00 | 1988 | 0.09 | −2 |
500 | 1220.00 | 1184 | 0.1 | 3 |
1000 | 1190.00 | 1122 | 0.1 | 6 |
2000 | 1230.00 | 1122 | 0.2 | 9 |
5000 | 1350.00 | 1274 | 0.2 | 6 |
10 000 | 1560.00 | 1516.76 | 0.21 | 3 |
ISO | ||||
2 | 7.02 | 4.83 | 0.02 | 31 |
5 | 17.30 | 11.93 | 0.03 | 31 |
10 | 45.80 | 23.14 | 0.05 | 50 |
20 | 136 | 45.8 | 0.2 | 66 |
30 | 249 | 147 | 0.3 | 41 |
50 | 451 | 410 | 0.3 | 9 |
100 | 1130.00 | 1023 | 0.1 | 10 |
150 | 1790.00 | 1705 | 0.08 | 5 |
200 | 1840.00 | 1823 | 0.08 | 1 |
500 | 1180.00 | 1152 | 0.08 | 2 |
1000 | 1150.00 | 1093 | 0.1 | 5 |
2000 | 1220.00 | 1097 | 0.1 | 10 |
5000 | 1430.00 | 1263 | 0.1 | 12 |
10 000 | 1780.00 | 1505 | 0.2 | 16 |
CONCLUSIONS
Organ dose coefficients for external proton beams in six idealized irradiation geometries (AP, PA, RLAT, LLAT, ROT and ISO) were calculated using the UFH/NCI adult male phantom in standing and sitting postures. As discussed in a previous paper for a female phantom(12), changing the posture of the phantom leads to differences in energy deposition in organs and tissues due to the dependence of the conversion coefficients values with the morphology and the irradiation geometry. A set of sex-averaged effective dose conversion coefficient were calculated and provided. The result was compared with conversion coefficients provided in ICRP publication 116 and it was observed that in general the UFH/NCI conversion coefficients values were below the reference values. Below 100 MeV the differences were much higher due to the differences in skin and breast dose coefficients. Conversion coefficients are very sensitive to differences in voxel size and organ position. Results for effective dose coefficients in standing and sitting postures of the phantom were also compared. Effective dose coefficients were around 18% higher in the standing posture especially below 100 MeV in AP and PA geometry. For lateral geometries and below 20 MeV, values in the sitting phantom were around 16% higher. In ISO and ROT geometries the differences were, for almost all energies, below 5% and 10% respectively.
Supplementary Material
ACKNOWLEDGEMENTS
The authors thank UFS, CNPq, INCT em Metrologia das Radiações em Medicina and CAPES for the financial support.
Supplementary Material
Supplementary material can be found at RADIATION PROTECTION DOSIMETRY online.
REFERENCES
- 1. International Commission on Radiological Protection Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures. ICRP Publication 116. Ann. ICRP 40(2–5) (Amsterdam: Elsevier; ) (2010). [DOI] [PubMed] [Google Scholar]
- 2. Ferrari A., Pelliccioni M. and Pillon M.. Fluence to effective dose conversion coefficients for protons from 5 MeV to 10 TeV. Radiat. Prot. Dosim. 71, 85–91 (1997). [Google Scholar]
- 3. Bozkurt A. and Xu X. G.. Fluence-to-dose conversion coefficients for monoenergetic proton beams based on the VIP-man anatomical model. Radiat. Prot. Dosim. 112, 219–235 (2004). [DOI] [PubMed] [Google Scholar]
- 4. Zhang G., Liu Q., Zeng S. and Luo Q.. Organ dose calculations by Monte Carlo modeling of the updated VCH adultmale phantom against idealized external proton exposure. Phys. Med. Biol. 53, 3697–3722 (2008). [DOI] [PubMed] [Google Scholar]
- 5. Sato T., Endo A., Zankl M., Petoussi-Henss N. and Niita K.. Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms. Phys. Med. Biol. 54, 1997–2014 (2009). [DOI] [PubMed] [Google Scholar]
- 6. Cavalcante F. R., Galeano D. C., Carvalho Júnior A. B. and Hunt J.. Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry. Radiat. Phys. Chem. 95, 158–160 (2014). [Google Scholar]
- 7. Galeano D. C., Cavalcante F. R., Carvalho Júnior A. B. and Hunt J.. Comparison of conversion coefficients for equivalent dose in terms of air kerma using a male adult voxel simulator in sitting and standing posture with geometry of irradiation antero-posterior. Radiat. Phys. Chem. 95, 233–235 (2014). [Google Scholar]
- 8. Galeano D. C., Santos W. S., Alves M. C., Souza D. N. and Carvalho Júnior A. B.. Fluence-to-dose conversion coefficients based on the posture modification of Adult Male (AM) and Adult Female (AF) reference phantoms of ICRP 110. Radiat. Phys. Chem. 121, 50–60 (2016). [Google Scholar]
- 9. Han E. Y., Ha W., Jin Y., Bolch W. E. and Lee C.. Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident. J. Radiol. Prot. 35, 37–45 (2015). [DOI] [PubMed] [Google Scholar]
- 10. Olsher R. H. and Riper K. A. V.. Application of a sitting MIRD phantom for effective dose calculations. Radiat. Prot. Dosim. 116, 392–395 (2005). [DOI] [PubMed] [Google Scholar]
- 11. Su L., Han B. and Xu X. G.. Calculated organ equivalent doses for individuals in a sitting posture above a contaminated ground and PET imaging room. Radiat. Prot. Dosim. 148, 439–443 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Alves M. C., Santos W. S., Lee C., Bolch W. E., Hunt J. G. and Carvalho Júnior A. B.. Organ and effective dose conversion coefficients for sitting female hybrid computational phantom exposed to monoenergetic protons in idealized irradiation geometries. Phys. Med. Biol. 59, 7957–8003 (2014). [DOI] [PubMed] [Google Scholar]
- 13. Piegl L. On NURBS: a survey. IEEE Comput. Graph. Appl. 11, 55–71 (1991). [Google Scholar]
- 14. Lee C., Lodwick D., Hasenauer D., Williams J. L., Lee C. and Bolch W. E.. Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models. Phys. Med. Biol. 52, 3309–3333 (2007). [DOI] [PubMed] [Google Scholar]
- 15. Bartlett D. T. Radiation protection aspects of the cosmic radiation exposure of aircraft crew. Radiat. Prot. Dosim. 109, 349–355 (2004). [DOI] [PubMed] [Google Scholar]
- 16. Heinrich W., Roesler S. and Schraube H.. Physics of cosmic radiation fields. Radiat. Prot. Dosim. 86, 253–258 (1999). [DOI] [PubMed] [Google Scholar]
- 17. Reitz G. Radiation environment in the stratosphere. Radiat. Prot. Dosim. 48, 5–20 (1993). [Google Scholar]
- 18. Ferrari A., Pelliccioni M. and Rancati T.. Calculation of the radiation environment caused by galactic cosmic rays for determining air crew exposure. Radiat. Prot. Dosim. 93, 101–114 (2001). [DOI] [PubMed] [Google Scholar]
- 19. Ferrari A. and Pelliccioni M.. On the conversion coefficients for cosmic ray dosimetry. Radiat. Prot. Dosim. 104, 211–220 (2003). [DOI] [PubMed] [Google Scholar]
- 20. Sato T., Endo A., Zankl M., Petoussi-Henss N., Yasuda H. and Niita K.. Fluence-to-dose conversion coefficients for aircrew dosimetry based on the new ICRP recommendations. Prog. Nucl. Sci. Technol. 1, 134–137 (2011). [Google Scholar]
- 21. Lee C., Lodwick D., Hurtado J., Pafundi D., Williams J. L. and Bolch W. E.. The UF family of reference hybrid phantoms for computational radiation dosimetry. Phys. Med. Biol. 55, 339–363 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. International Commission on Radiological Protection The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP 37(2–4) (Oxford: Pergamon) (2007). [DOI] [PubMed] [Google Scholar]
- 23. International Commission on Radiological Protection Adult Reference Computational Phantoms ICRP Publication 110. Ann. ICRP 39(2) (2009). [DOI] [PubMed]
- 24. Pelowitz D. B. MCNPX User's Manual Version 2.7.0 (Los Alamos: Los Alamos National Laboratory; ) (2011. LA-CP-11-00438 . [Google Scholar]
- 25. Han E. Y., Ha W. H., Jin Y. W., Bolch W. E. and Lee C.. Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident. J. Radiol. Prot. 35, 37–45 (2015). [DOI] [PubMed] [Google Scholar]
- 26. International Commission on Radiological Protection . Basic Anatomical and Physiological Data for Use in Radiological Protection: Reference Values . ICRP Publication 89. Ann. ICRP 32(3–4) (2002). [PubMed]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.