Skip to main content
Data in Brief logoLink to Data in Brief
. 2018 Nov 3;21:2059–2062. doi: 10.1016/j.dib.2018.10.167

Data on the characterization of Raney nickel powder and Raney-nickel-coated electrodes prepared by atmospheric plasma spraying for alkaline water electrolysis

Ji-Eun Kim a,c, Ki-Kwang Bae a, Chu-Sik Park a, Seong-Uk Jeong a, Kyeong-Ho Baik b, Jong-Won Kim a, Young-Ho Kim d, Kyoung-Soo Kang a,, Ki-Bong Lee c
PMCID: PMC6262154  PMID: 30533452

Abstract

The data presented in this article are related to the research article entitled: “Electrochemical characterization of Raney nickel electrodes prepared by atmospheric plasma spraying for alkaline water electrolysis” (Kim et al., 2018). This article describes the characterization of raw Ni-Al alloy and Raney Ni powders via X-ray diffraction (XRD) and energy dispersive X-ray spectroscopy (EDS), and presents the EDS data of the prepared electrodes.


Specifications table

Subject area Electrochemistry
More specific subject area Alkaline electrolysis
Type of data Figure, Tables
How data was acquired XRD (D/max 2500 PC, Rigaku); EDS (X-MAX 50, Horiba Scientific)
Data format Analyzed
Experimental factors Samples were treated in alkaline solution for 24 h at 80 °C to leach Al. Heat treatment of the electrode and powder was carried out at 610 °C for 1 h under hydrogen atmosphere.
Experimental features XRD pattern of samples; chemical composition of samples via EDS
Data source location Daejeon, Korea
Data accessibility Data is displayed within this article.
Related research article (Kim et al., 2018) [1]

Value of the data

  • The data show that the composition of Ni–Al alloy powder is changed when its irradiated by plasma spraying method with a high-temperature environment.

  • The data presented in this article provide information on the effects of hydrogen annealing on the Ni–Al alloy powder and Ni–Al alloy electrode coating prepared by APS.

  • The data allow other researchers to compare the Raney nickel electrode prepared by APS with those prepared by other methods.

1. Data

Fig. 1 shows the XRD patterns of the Ni-Al alloy powder and Raney Ni powder prepared by dealloying Ni-Al of Al. Table 1 presents the EDS data for the electrode surface coated with Ni-Al alloy by APS and the electrode surface after Al leaching. Table 2 shows the EDS data for the Ni-Al alloy powder and Raney Ni powder prepared by leaching Al from the Ni-Al alloy. Finally, Table 3 shows the EDS data for the Ni-Al-alloy-coated electrode after annealing under hydrogen atmosphere and the Al-leached electrode.

Fig. 1.

Fig. 1

XRD patterns of (a) Ni-Al alloy powder and (b) Raney Ni powder.

Table 1.

EDX analysis of Ni-Al alloy coated electrode surface (a) as prepared and (b) after Al leaching.

wt. % As prepared After Al leaching
Ni 53.09 66.25
Al 32.65 21.02
O 14.26 12.73
Ni/Al 1.62 3.15

Table 2.

EDX analysis of Ni-Al alloy power and Raney Ni powder after Al leaching.

wt. % Ni-Al alloy powder Raney Ni powder
Ni 60.86 65.54
Al 35.21 8.07
O 3.92 26.39
Ni/Al 1.73 8.12

Table 3.

EDX analysis of Ni-Al alloy coated electrode surface (a) as prepared with hydrogen heat treatment and (b) after Al leaching.

wt. % As prepared After Al leaching
Ni 58.06 65.92
Al 31.18 9.55
O 10.76 6.9
Ni/Al 1.86 6.90

2. Experimental, materials, and methods

Ni-Al alloy powder (Yakuri Pure Chemicals) was used for XRD and EDS analyses. The powder was sieved to particle sizes of 12–45 μm. Raney Ni powder was prepared by Al leaching. Al was selectively leached for 24 h at 80 °C using 30 wt% potassium hydroxide (Samchun Chemicals, 95.0%) and 10 wt% potassium sodium tartrate tetrahydrate (Alfa Aesar, 99%). After Al leaching, the electrodes were rinsed with distilled water and dried under 1.6 vol% oxygen atmosphere to stabilize the pyrophoric Raney Ni surface. Heat treatment of the coated electrodes under hydrogen atmosphere was conducted by first placing the electrodes in a furnace (WiseTherm), which had been evacuated to create a vacuum and subsequently filled with Ar. Ar was then replaced with H2 to 100 vol%, and the electrodes were heat treated for 1 h up to 610 °C at a heating rate of 5 °C/min. After heat treatment, H2 was again replaced with Ar and the furnace was allowed to cool down naturally. To prepare the Ni-Al-alloy-coated electrode, a disc-shaped Ni plate with a diameter of about 20 mm and thickness of about 0.6 mm was used for the substrate. Prior to coating, sand blasting was conducted to create roughness. The coating layer was prepared using an APS gun (SG-100, Praxair Surface Technologies) with an output of 600 A, while maintaining a distance of 100 between the spray gun and substrate. During the coating process, the carrier gas, Ar, was supplied at 50 psi. Al leaching and heat treatment under H2 atmosphere was conducted in the same manner as that for the Ni-Al alloy powder. The crystalline structures of the Ni-Al alloy and Raney Ni powders were analyzed using an X-ray diffractometer (D/max 2500 PC, Rigaku). XRD measurements were made within the 2θ range of 10–90°, using Cu Kα (λ = 1.5056 Å) radiation energy with a voltage of 40 kV and current of 150 mA. The compositions of the powder and electrode surface were analyzed using an energy dispersive X-ray spectrometer (X-MAX 50, Horiba Scientific).

Acknowledgments

This work was supported by “Renewable Energy Program” of the Korea Institute of Energy Technology Evaluation and Planing(KETEP), granted financial resource from the Ministry of Trade, Industry and Energy, South Korea (No. 20173030041350).

Footnotes

Transparency document

Transparency data associated with this article can be found in the online version at https://doi.org/10.1016/j.dib.2018.10.167.

Transparency document. Supplementary material

Supplementary material

mmc1.doc (31.5KB, doc)

.

Reference

  • 1.Kim J.E., Bae K.K., Park C.S., Jeong S.U., Baik K.H., Kim J.W., Kim Y.H., Kang K.S., Lee K.B. Electrochemical characterization of Raney nickel electrodes prepared by atmospheric plasma spraying for alkaline water electrolysis. J. Ind. Eng. Chem. 2018 doi: 10.1016/j.dib.2018.10.167. (in submission) [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary material

mmc1.doc (31.5KB, doc)

Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES