Abstract
Since the 1970s, a great deal of attention has been paid to the development of semiconductor-based biosensors because of the numerous advantages they offer, including high sensitivity, faster response time, miniaturization, and low-cost manufacturing for quick biospecific analysis with reusable features. Commercial biosensors have become highly desirable in the fields of medicine, food, and environmental monitoring as well as military applications, whereas increasing concerns about food safety and health issues have resulted in the introduction of novel legislative standards for these sensors. Numerous devices have been developed for monitoring biological processes such as nucleic acid hybridization, protein–protein interaction, antigen–antibody bonds, and substrate–enzyme reactions, just to name a few. Since the 1980s, scientific interest moved to the development of semiconductor-based devices, which also include integrated front-end electronics, such as the extended-gate field-effect transistor (EGFET) biosensor, one of the first miniaturized chemical sensors. This work is intended to be a review of the state of the art focused on the development of biosensors and chemosensors based on extended-gate field-effect transistor within the field of bioanalytical applications, which will highlight the most recent research reported in the literature. Moreover, a comparison among the diverse EGFET devices will be presented, giving particular attention to the materials and technologies.
Keywords: EGFET, ISFET, electrochemical cell, enzymatic biosensor, DNA–DNA biosensor, immunosensor, antigen–antibody biosensor, ionic sensor, chemosensor
1. Introduction
The earliest example of a solid-state device for the sensing of ionic activities can be traced back to 1970 with the ion-sensitive field-effect transistor (ISFET), derived from an insulated-gate field-effect transistor (IGFET) [1]. In this class of devices, the gate consists of only a thin SiO2 layer in contact with an electrolyte solution contained in an electrochemical cell, and the potential at the interface electrolyte/solution influences the drain current [1,2]. The device and the electrical connections are separated from the solution, avoiding possible damage caused by the penetration of liquids, which guarantees insulation from the external environment as well as biocompatibility. The information retrieved from the sample, which in the first approximation is the analyte concentration, depends on the interfacial potential with respect to an external reference electrode, which is part of the sensor itself. It provides a known, stable potential that does not depend on the intensity of the current (i.e., zero-current condition). The development of extended-gate field-effect transistor (EGFET) sprang from ISFET technology, and was first proposed by Van der Spiegel in 1983 [3].
Unlike ISFET, EGFET preserves the gate region as a standard metal-oxide-semiconductor field-effect transistor (MOSFET) and the sensing membranes are physically separated [4,5,6]. Thus, the activity of target analyte results in an additional chemical contribution to the threshold voltage (Vth) [7]. The main applications of EGFETs are associated with the detection of ionic species, pH, and specific molecules (through the functionalization of sensitive surfaces) such as urea and glucose [7,8,9,10,11,12]. Apart from its prevalent use in the fields of biosensing and chemical sensing, physical sensors for high-frequency ultrasound detection (e.g., hydrophones) have been realized through EGFET technology, often referred to as piezoelectric-oxide-semiconductor field-effect transistors (POSFETs) or piezoelectric gate on FETs (PiGoFETs) [13,14,15].
The foremost problem with these solid-state devices is threshold voltage drift, which depends on the chemistry of the environment under test [16,17]. This phenomenon manifests itself through a slow, continuous change in the threshold voltage of the device, usually in one direction. Different technical solutions have been proposed for its improvement, such as encapsulation techniques, even though there is not yet any general technology for the poor isolation between the device and the chemical environment [18]. The most diffused involve multilayer materials, such as the backside gate type with Si–SiO2–Si (SIS) [19] or silicon-on-sapphire (SOS) structure [20,21]. Other techniques include the use of polymeric membranes [22], photoresist [23], glass-bonded [24], and epoxy resin encapsulation [25]. Even though a great deal of effort has been made toward solving this limiting factor, the effects of drift remain a sticking point [16,26]. Recently, the introduction of microfluidics together with the integration of EGFET biosensors has made the packaging easier, with a reduction in the volume of samples and reagents [27]. The following sections will look more closely at the principal components and relative functioning principles of EGFET, along with their foremost applications.
2. Fundamental Principles of EGFET
2.1. FET Device
The principal component of an EGFET device is a MOSFET, which confers long-term stability on environmental variations (such as light and temperature), facilitates insulation and encapsulation, and makes it possible to vary the geometry of the sensing membrane more easily than an ISFET [28,29,30,31]. The working principle is that of a conventional MOSFET, except for the sensing layer, which is immersed in a buffer solution positioned at a certain distance from the device [32]. As can be seen in Figure 1a, the device consists of a FET with high input impedance, a signal line (better if shielded), and the sensitive area connected to the gate [3]. EGFET allows the use of both on-chip integrated preamplifiers and, in the most recent configurations reported in the literature, discrete commercial-type devices connected to the gate extension. The latter is more precisely referred to as separative-extended gate-field-effect transistor (SEGFET), as shown in Figure 1b. Sometimes, it is also named ExGFET in order to avoid ambiguity with electrolyte-gated field-effect transistor.
The impedance of the sensitive layer of the EGFET is usually different from the ISFET, in which it coincides with a high-impedance-gate dielectric. The sensitive layer (e.g., redox-responsive material) of an EGFET is instead characterized by low impedance, with consequently higher conductivity and sensitivity [33]. According to the MOSFET literature, the equation that binds the channel current IDS to the characteristics of the EFGET, usually in the linear region, is as follows:
(1) |
where W and L are the width and length of the channel, μ is the mobility, Cox is the gate oxide capacitance per unit area, and VRef and VDS are the applied reference electrode and the drain-to-source voltages, respectively. In Equation (1), the only parameter linked to the analyte (i.e., the activity of the analyte) is the overall threshold voltage V*th of the device [30,32].
The aspect ratio W/L, and thus the transconductance gm, influences the performance of the device, particularly the input-referred noise. High gm values, and consequently devices with a large surface area, reduce the flicker (1/f) noise, which is implicated in the surface conduction phenomena of the MOS caused by carrier recombination and interface traps. In fact, the oxide–semiconductor interface is characterized by random trapping and detrapping of the carriers that flow through the channel, generating flicker in the drain current [34]. Since one of the aims of the EGFET is to further reduce the response time, by imposing the minimum possible channel length, the gate width can be modified, increasing the aspect ratio. An empirical model for evaluating the power spectral density (PSD) of the flicker noise is expressed by the following:
(2) |
where f is the working frequency, M is an empirical parameter, and γ is a process parameter [34]. The PSD increases with the increase of the drain current depending on the region of operation, while large surface positively affects SIDS. Humidity at high temperature has a different impact on the flicker noise depending on the channel type. Humidity affects flicker noise, mostly for p-channel devices, while in an n-channel, the contribution is negligible [35]. Therefore, the increase of W impacts the performance, especially for low-frequency applications [14]. In addition to the flicker noise, both the device and the transduction interface are intrinsically affected by thermal noise, depending on the leakage current at the oxide interface [14,15]. Thermal noise spectral density has been investigated in MOSFETs by Van der Spiegel in strong, moderate, and weak inversion regions in high-W/L devices. The proposed model (valid only for “long channel” devices) highlighted that n-channel MOSFET is characterized by higher noise due to a larger body effect apart from strong inversion, where the effect becomes less significant with respect to the p-channel device [36]. Latch-up and noise reduction can be obtained by proper bulk/well biasing and design layout. Apart from the noise ascribable to the FET, and eventually to the signal line if not properly shielded, the EGFET sensor does not significantly suffer from other external interference due to coupling from high to low impedance, since it is physically located near where the reaction takes place [37].
The possibility of designing ultra-short-channel EGFETs makes it necessary to revise and modify many of the corresponding long-channel counterparts in terms of channel doping, oxide thickness, and potential distribution. Different empirical models have been proposed for adjusting the device parameters preserving the overall MOSFET behavior [38]. The length at which the long-channel behavior is maintained is as follows:
(3) |
where C is a constant evaluated by fitting Equation (3), xj is the junction depth, and Ws and Wd are the source and drain depletion depths (that can be subsequently designed), respectively [38]. The integration of a source follower as an input stage together with a bootstrap reduces the input capacitance, which increases the overall sensitivity of the sensor [3]. Concerning the signal line, in the original design, it could be up to several millimeters long, thus the use of an insulating layer allows both electric and chemical shielding, reducing even crosstalk in the case of sensors located near each other [3]. This is even more evident in the most recent EGFET devices, in which the signal line is even longer. Moreover, bootstrapping the shield means that there will be less capacitive coupling between the signal line and the insulating shield, also impacting the bandwidth of the sensor [39]. The threshold voltage V*th also depends on the typical parameters of the chemical environment in agreement with the following:
(4) |
where ERef is the reference electrode potential, χsol is the superficial dipole potential of the electrolyte, WM is the work function of the reference electrode, ϕ is the potential of the surface at the electrolyte/sensing membrane interface, and q is the charge [2]. In other devices, such as those exploiting the electrolyte–insulator–semiconductor (EIS) capacitive effect, an external electronic circuit is required to amplify the signal. Moreover, the equivalent capacitive model of the EIS is complex, notwithstanding its simple structure [40].
EGFETs were designed as devices that had to improve the limits, in terms of the output variability of ISFETs, and their performance has been investigated under various conditions such as temperature [41], light exposure [31], and different chemical environments [28]. As compared to ISFETs, they have shown greater chemical and thermal stability as well as better output stability under different incident light conditions, and increased current sensitivity [41,42]. EGFET devices have been widely used in bioanalytical applications for detection of pH, enzymes, and proteins [28,43]. As far as their design is concerned, different topologies have been reported. Figure 2 shows an example of an integrated circuit, in which the noteworthy dimensions of the gate electrode (sensitive area) are evident as compared to the source and drain electrodes.
Signal-to-noise-ratio (SNR) can be used as a performance metric that combines most of the parameters involved during EGFET fabrication, such as gm, device dimensions, and oxide traps. Rajan et al. pointed out that scaling did not always lead to devices with higher performance. A linear dependence was observed between SNR and √WL, which encouraged the design of higher-surface-area EGFETs for improved sensitivity and limits of detection [44]. The design of an optimal gate area rather than gate width is preferred because flicker noise contribution depends on WL and is independent of W/L ratio and the DC bias conditions [45]. As a general rule, for a standard MOSFET, the gate length should be 5–10 times larger than the characteristic length of source-drain lateral potential decays [46]. Van der Spiegel et al. proposed an extended-gate FET with an aspect ratio of 1900/10 μm/μm with the aim of improving gm and reducing the noise [14]. SNR is bias-dependent and thus can be optimized in order to further reduce power consumption [44].
2.2. Sensitive Layer
In bioanalytical applications, the potential of specific chemical species involved in the electrochemical reaction is transduced to an electrical signal proportional to the target information (e.g., concentration) [47,48,49,50,51]. Depending on the electrochemical cell configuration chosen, the electrical characterization can be performed through potentiometric, amperometric, or conductometric schemes [52]. The suitability of a particular configuration depends on the specific analyte, the sensitivity and selectivity required, and the design of the overall system. The monitoring of an EGFET-based electrochemical cell requires one or more additional electrodes (i.e., reference and counter electrodes) besides the electrode where the reaction takes place (i.e., working electrode) [52,53]. The two-electrode configuration, the most commonly employed, can set detection limits due to limiting factors (e.g., overvoltage with respect to the zero current half-cell potential) [51]. One alternative solution is to use a three-electrode configuration by adding a counter electrode (e.g., amperometric scheme).
Potentiometric configuration is primarily involved in evaluating the potential across an interface, often a membrane [54,55]. In direct potentiometry, the electromotive force is ideally a function of the activity of a single ion so that it can be selectively evaluated, even in the presence of other species [41]. Most of the EGFETs proposed in the literature exploit the potentiometric configuration, as shown in Figure 3a. The system consists of a working electrode that has a sensitive layer or surface on which the electrochemical reaction takes place. The charge density on the surface of the sensing film will change the surface potential of the sensing film itself, modifying the characteristic curve of the transistor as well. More recently, ion-sensitive devices exploiting floating gates without the use of a reference electrode have been investigated by applying a bias voltage to a control gate rather than a reference electrode [56,57]. Typical characteristic curves for an ion-sensitive EGFET are shown in Figure 3b, in which the current–voltage characteristics of the transistor change depending on the analyte, and the input signal is assessed by the transfer characteristics (ID–VRef) using a semiconductor parametric device analyzer [41].
Shinwari et al. proposed an in-depth analysis of microfabricated electrodes for biosensors, including those based on FET technology [58]. The most frequently employed electrodes (especially those used as reference) are fabricated in Ag/AgCl because of their smaller size, simpler fabrication, and integration into the device. In addition, these electrodes are not susceptible to the corrosion phenomena of the solution. Other electrodes are hydrogen, saturated calomel electrode (SCE) based on elemental mercury and mercury (I) chloride, copper/copper sulfate, and palladium/hydrogen. However, the reference electrode does not have stable potential depending on the circulating current, but the use of high-input MOS interface minimizes any leakage current that can change its potential [58].
Working electrode materials play an important role in the specific biosensors to be fabricated. Materials can be categorized as metal-based, carbon-based, and polymer-based electrodes. In many cases reported in the literature, the working electrodes are functionalized with nanomaterials and mediators to enhance sensitivity and selectivity [2]. Working electrodes based on metal oxides (insoluble and stable in solution), as discussed in more detail later, have been classically investigated for pH sensors and represent a widespread application involving EGFET devices [4,8,9]. The general approach that is largely accepted is based on the theory of the electric double layer and the electric charge gathered at the oxide surface. It is valid for metal oxides whose charging mechanisms follow the association–dissociation of an amphoteric group [2]. Apart from pH detection, the investigation of sensitive layers functionalized with biological molecules (e.g., enzymes, antibodies, nucleic acids) allows for specific binding or catalytic reactions, resulting in electron transfer related to the specific analyte or a group of analytes (usually oxidases). The functionalized bio-selective surface overcomes the slow kinetics of the target molecules, even though enzyme-free electrodes have also been investigated more recently with good results. There are a variety of available enzymes and each one is appropriate to catalyze an electrodic reaction in the presence of a specific analyte. Table 1 shows a few representative substrates investigated for the fabrication of sensitive surfaces, the related enzymes, the target molecules, and the immobilization techniques adopted. The ability to catalyze a large number of reactions not being consumed, allowing a “continuous” use of the device, is one of the main reasons for the common use of enzymatic biosensors. However, the lifetime of the sensor is limited by the stability of the enzyme.
Table 1.
Refs. | Substrate | Functionalization | Target | Method of Immobilization |
---|---|---|---|---|
[59] | Au/Ag–NWs | HRP | Hydrogen peroxidase | Covalent bonding |
[60] | Carbon/ZnO | Hb | Covalent bonding | |
[61] | GC/Ag NPs/MWNTs | Hb | Entrapment | |
[62] | Graphene/Au–NPs | Enzyme-free | ||
[63] | Nafion modified GC/CNT | Enzyme-free | ||
[64] | Au/Ag–NCs | HRP/GOx | Glucose | Entrapment |
[65] | ITO/CS–PPy Au–NPs | GOx | Entrapment | |
[66] | Ag/CNT/CS | GOx/HRP | Layer technique | |
[67] | BDD/graphene/Pt–NPs | GOx | Adsorption | |
[68,69,70,71,72] | Si/VACNFs | GOx/HRP | Adsorption | |
[73] | Graphite NPs | GOx | Covalent bonding | |
[74] | Pt/Pt–NPs–PPy | SOx | Sulfite | Entrapment |
[75] | ITO/PEDOT:PSS | TPM | Dopamine, ascorbic acid | CVD |
[76] | FTO/GONPs–PPy | BOx | Bilirubin | Entrapment |
[77] | GC | DHB | Adenine dinucleotide | Potential activation |
[78] | BDD/MWCNTs | Tyrosinase | Bisphenol A | Entrapment |
[79] | GC/PEDOT/MWCNTs | SOD | Wine antioxidants | nr |
NW, nanowire; GC, glassy carbon; NP, nanoparticle; MWNT, multiwalled carbon nanotube; CNT, carbon nanotube; NC, nanocube; CS, chitosan; PPy, polypyrrole; BDD, boron-doped diamond; VACNF, vertically aligned carbon nanofiber; PEDOT:PSS, poly(3,4–ethylenedioxythiophene) polystyrene sulfonate; GONP, graphene oxide nanoparticle; HRP, horseradish peroxidase; Hb, hemoglobin; GOx, glucose oxidase; BOx, bilirubin oxidase; SOx, sulfite oxidase; TPM, 3–(trichlorosilyl) propyl methacrylate; CVD, chemical vapor deposition; DHB, 3,4–dihydroxybenzaldehyd; SOD, superoxide dismutase; nr, not reported.
Recent studies have also reported a further classification of enzymatic sensors into three successive generations of devices: the first, which is limited by nonspecific electroactive particles; the second, in which mediators are employed as electron carriers; and the third, in which there is a direct electron transfer between the electrode and the enzyme (absence of mediators) [80]. In addition to biosensor devices that exploit catalytic enzyme activity, molecular interactions such as antigen–antibody reactions (immunosensors) and nucleic acid interactions (genosensors, also referred to as bioaffinity devices), represent a field of increasing interest for EGFET-based devices [7]. The following sections review the most widespread literature on EGFET, classified for each specific application.
3. Applications of EGFET-Based Sensors
3.1. pH Sensors
pH is an extremely important biological parameter for human health, providing information for diagnosing many diseases as well as enhancing therapeutic treatment. It can also be used as a tool for monitoring biological and biochemical processes. One of the foremost recent examples concerns tumor cells, for which an elevated pH is an indicator of the onset of cell proliferation [81,82]. Monitoring pH levels of living cells is also important in endocytosis and phagocytosis [83,84]. Among the analytical models developed so far, the most widespread is the site-binding model, which was first introduced by Yates in 1973 (site-dissociation model) and then further developed by the same group. The model describes the electric double layer at the oxide–electrolyte interface, supposing an amphoteric oxide layer [85]. The pH of the electrolyte solution influences the hydroxyl groups at the surface (i.e., sensing membrane potential) as follows:
(5) |
where , pHPZC corresponds to the pH value for which the surface charge is null, k is the Boltzmann constant, T is the temperature, and β is the buffer capacity, a parameter that characterizes the ability of the sensitive surface to buffer pH changes (β is an inherent property of the sensing material) [86]. According to the site-binding model, the number of binding sites on the sensing membrane can change the potential of the electrolytic interface, as well as the potential of the sensing membrane, as expressed by [87]:
(6) |
The difference in potential between the reference electrode and the sensing membrane is Vout = VRef − ϕ [88]. The applications of pH sensors are numerous. For example, they are used in the monitoring of drinking water quality, in soil analysis, and in the inspection of processes in the food industry [89,90]. Different oxide substrates have been used as sensing membranes, such as tantalum oxide (Ta2O5), indium–tin oxide (ITO), tin oxide (SnO2), platinum dioxide (PtO2), vanadium anhydride (V2O5), xerogel, niobium oxide (Nb2O5), zinc oxide (ZnO), titanium dioxide (TiO2), and ruthenium oxide (RuO2), to name a few [41,42,91,92,93,94,95,96,97,98,99,100,101,102,103]. To further reduce manufacturing costs, particularly of the sensing membrane, recycled materials from other sectors have also been investigated. Industrial-grade touch panel film (TPF) is an example. TPF is a multilayered material composed of ITO/SiO2/Nb2O5 that has several advantages when used as a pH sensor, such as good sensitivity and fast response speed [104]. As already mentioned, the list of materials used as sensing membranes is very long, and the choice depends mainly on the range of interest and the required sensitivity [95,104,105,106,107,108,109]. Most of the efforts reported in the literature have been aimed at improving the performance of EGFET-based pH sensors with the use of different materials, including composites. The buffer capacity β has been intensively investigated to improve sensor sensitivity. According to the literature, it can be expressed as:
(7) |
where Ns is the surface site numbers, Ka and Kb are equilibrium constants, and Cd is the differential capacitance of the electrolyte, which accounts for the storage of electric charge after experiencing electrostatic potential [87]. The buffer capacity and the differential capacitance mostly affect the pH sensitivity of the sensor, leading to a maximum sensitivity for β >> 1, which is limited to 59 mV/pH at 297 K (the so-called Nernst limit) [110,111,112]. Nevertheless, studies have reported materials showing super-Nernstian sensitivity [113]. Table 2 shows a few representative pH sensors based on EGFET with particular emphasis on the materials technology, the FET device, and the overall biosensor characteristics.
Table 2.
Ref. | Sensitive Material | Sensitivity (mV/pH) | Range | Linearity (%) | Drift (mV/h) | Hysteresis (mV) | Reference Electrode | Sensitive Area | FET Device | Type |
---|---|---|---|---|---|---|---|---|---|---|
[30] | ITO | 58 | 2–12 | nr | nr | 9.8 | SCE | 6 mm2 | CD4007UB | P |
[32] | SnO2 | 56–58 | 2–12 | nr | nr | nr | SCE | nr | CD4007UB or LF356N | P |
[41] | TiO2 | 59.89 | 1.8–12 | 93.50 | 0.041692–2.6007 | 5.3–9 | Ag/AgCl | 1 cm2 | NDP6060L | P |
[42] | V2O5 | 58.1 ± 0.8 | 2–10 | nr | nr | nr | nr | nr | CD4007UB | P |
[92] | ITO/PET | 50.1 ± 1.7 | 2–12 | 98.5 | 13.2 | nr | Ag/AgCl | Π × 22 mm2 | CD4007CN | P |
[94] | ITO/PET | 45.9–52.3 | 2.1–12.1 | 98.3–99.6 | nr | nr | Ag/AgCl | Π × 22 mm2 | CD4007UB | P |
[95] | SnO2 | 59.3 | 2–9.4 | nr | nr | nr | Ag/AgCl | nr | LT1167–I.A. | P |
[101] | AZO | 57.95 | 1–13 | 99.98 | 1.27 | 4.83 | Ag/AgCl | 2 × 2 mm2 | CD4007UB | A |
[104] | ITO/SiO2/Nb2O5 | 59.2 | 3–13 | 99.48 | 2% | 1.83% | Ag/AgCl | 20 × 20 mm2 | IC4007 | P |
[106] | ZnO nano-array | 45 | 4–12 | nr | nr | nr | Ag/AgCl | Π × 2.52 mm2 | CD4007UB | P |
[108] | SnO2/SiO2/glass | 58 | 1–9 | nr | nr | nr | Ag/AgCl | 1.5 × 1.5 mm2 | LT1167–I.A. | P |
[109] | SnO2/ITO/PET | 53.8–58.7 | 2–12 | nr | nr | nr | Ag/AgCl | nr | LT1167–I.A. | P |
[113] | PdO | 62.87 ± 2 | 2–12 | 99.97 | 2.32 | 7.9 | Ag/AgCl | 0.25 cm2 | CD4007UBE | P |
[114] | InGaZnO | 59.5 | 2–10 | 99.7 | 3–9 | nr | Ag/AgCl | nr | CD4007 | P |
[115] | Glass | 55 | 2–12 | nr | nr | nr | nr | nr | CD4007UB | P |
[116] | CNT | 50.9 | 3–13 | 99.78 | nr | nr | nr | 1 × 2 cm2 | nr | P |
[117] | FTO | 54.10 | 2–12 | nr | nr | nr | nr | nr | CD4007UB | P |
PET, polyethylene terephthalate; AZO, aluminum-doped ZnO; P, potentiometric; A, amperometric; I.A., instrumentation amplifier; nr, not reported.
As shown, there are many usable sensitive layers that can facilitate the development of even more tailored sensor solutions for specific applications. Furthermore, EGFET-based sensors can be miniaturized and suitably integrated into different microsystems [118].
3.2. Urea Sensors
Urea is generally known as the best indicator for evaluating the level of uremic toxins in the bloodstream. Different types of biosensors have been proposed for urea detection, particularly based on ISFET and enzymatic field-effect transistor (EnFET) [8,119,120]. Urea sensors are widely used in medical diagnostics for pathologies such as kidney failure, leukemia, diabetes, and hyperthyroidism [121]. Urease is the specific immobilized enzyme used for the detection of urea, following the reaction:
(8) |
Urease catalyzes the hydrolysis of urea, which can be determined through a change in pH or the concentration of ammonium ions. Urease is immobilized on the sensing membrane by different methods, such as physical adsorption, entrapment, covalent bonding, and cross-linking [122,123,124,125,126]. Lately, in order to simplify the production process and improve the efficiency of enzyme/analyte bonds, urea sensors based on EGFET have been developed [95,127]. Covalent bonding is a very effective method of immobilization due to the strong interaction between the enzymes and the biological material, giving the biosensors longer time stability [119]. Alternative low-cost (inorganic) methods have also been developed, including plasma treatment (e.g., plasma-enhanced chemical vapor deposition) of ITO/polyethylene terephthalate (PET) substrate, which creates amino bonds on the surface and immobilizes urease [86,94]. Chen et al. developed an urea sensor based on EGFET technology using a structure made of tin dioxide (SnO2), ITO, and glass as sensing electrodes, characterized by a response time of 1–2 min with high immunity to variations of light and temperature [95]. Besides tin oxide, fluorine doped tin oxide (FTO) has also been used as a sensitive material on EGFET sensors, obtaining a pH sensitivity of 54.10 mV/pH (pH range from 2 to 12) and urea sensitivity of 8.92 µA/pCurea (see also Table 3) [117].
Table 3.
Ref. | Sensitive Material | Sensitivity | Range (mM) | Linearity (%) | Reference Electrode | Sensitive Area | FET Device | Type |
---|---|---|---|---|---|---|---|---|
[94] | ITO/PET | 21.2 mV/pCurea | 1.5–10 | 96.5 | Ag/AgCl | Π × 22 mm2 | CD4007UB | P |
49.7 mV/pCurea | 99.0 | |||||||
62.4 mV/pCurea | 98.6 | |||||||
[95] | SnO2/ITO | nr | 0.05–20 | Ag/AgCl | nr | LT1167–I.A. | P | |
[109] | SnO2/ITO/PET | nr | 0.04–0.33 | 97 | Ag/AgCl | nr | LT1167–I.A. | |
[117] | FTO | 8.92 μA/pCurea | 0.01–300 | nr | nr | nr | CD4007UB | A |
P, potentiometric; A, amperometric; I.A., instrumentation amplifier; nr, not reported.
A comparison among EGFET-, ISFET-, and EnFET-based urea sensors shows very similar performance in terms of sensitivity and dynamic range (see Table 3). The majority of EnFETs are based on pH-sensitive FETs, while in some cases they use ISFETs [128]. Pijanowska et al. proposed an ISFET-based urea biosensor for human blood serum with a response time of 80 s and a lifetime of 35 days [8]. Yu et al. proposed a Ta2O5-based EnFET that had a response time of about 120 s [119]. Concerning EGFET urea sensors, the response time of representative devices is limited to around 2–3 min with a lifetime of >6 days [94,95]. Being of clinical interest (especially with regard to blood), EGFET-based urea sensors represent a promising technology (especially for the development of disposable devices) that indirectly detects urea concentration through the evaluation of pH variation as a result of an enzymatically catalyzed reaction.
3.3. Glucose Sensors
The first biosensor for the measurement of glucose was described by Clark and Lyons in 1962 [129]. The principle of detection is based on the generation of gluconate and hydrogen peroxide (H2O2) catalyzed by glucose oxidase enzyme (GOD) in a glucose solution. By means of a dissociation reaction of H2O2, the potential of the sensing membrane changes. The chemical reaction, catalyzed by the GOD enzyme, is as follows:
(9) |
Zinc oxide (ZnO) is a common material used for the fabrication of sensing membranes. Nanostructured ZnO layers (e.g., micro/nanowires, nanotubes, and nanonails) fabricated at low temperature (<100 °C) or high temperature (e.g., 650 and 960 °C) have been widely investigated in glucose detection, showing a linearity greater than 99% and good sensitivity (from 21.7 to 89.74 μA·mM−1·cm−2) depending on the specific nanostructure [130,131,132,133]. In fact, besides temperature, surface morphology influences the sensing characteristics of the glucose sensors (e.g., sensitivity). One-dimensional ZnO nanostructure layers (e.g., nanotubes, nanorods, and nanonails) have been widely investigated because of their high surface-to-volume ratio, which improves the sensing properties of the sensors [130,131,132,133]. Vertically aligned ZnO nanowires are inherently characterized by a high surface-to-volume ratio. The length and width of ZnO nanowires, which can be controlled during the process, lead to a tunable surface area and thus the device’s sensitivity [134]. In order to increase the conductivity of this membrane, the zinc oxide can be “loaded” with metallic elements. When aluminum is chosen, it is referred to as AZO (aluminum-doped ZnO). Wang et al. proposed an EGFET based on AZO nanostructure fabricated with a low-temperature process that showed promising sensing characteristics (e.g., sensitivity of 60.5 μA·mM−1·cm−2 and linearity > 99%) for a disposable biosensor [101]. The morphology of AZO nanostructures is related to aluminum content. Well-matched ratios of aluminum and ZnO showed higher crystallinity and better conductivity, resulting in superior sensing characteristics [107]. Due to their clinical interest and an electrically favorable chemical reaction, glucose sensors have been widely investigated on different biological fluids (e.g., blood, saliva, tears, sweat). Table 4 presents the main characteristics of EGFET-based glucose sensors with particular emphasis on materials and performance.
Table 4.
Ref. | Electrode | Sensitivity | Range (mM) | Linearity (%) | Drift (mV/h) | Hysteresis (mV) | Reference Electrode | Sensitive Area (μm2) | FET Device | Type |
---|---|---|---|---|---|---|---|---|---|---|
[101] | AZO | 60.5 μA·mM−1·cm−2 | 0–13.9 | 99.96 | 1.27 | 4.83 | Ag/AgCl | 2 × 2·106 | CD4007UB | A |
[135] | Au | −61.6 mV/decade | 0.125–1 | 99.60 | nr | nr | Ag/AgCl | 10 × 10 | 0.6 μm CMOS | P |
[136] | PPI/NiTsPc | nr | 0.05–1 | nr | nr | nr | Ag/AgCl | nr | AD620 I.A. | P |
[137] | Au | −58 mV/decade | 0.1–2 | 99.97 | 0.50 | nr | Ag/AgCl | 20 × 56 | 32 × 32 array 1.2 μm CMOS | P |
[138] | Ru-doped TiO2 | 320 μV/(mg/dL) | 5.55–27.55 | 99.50 | nr | nr | Ag/AgCl | 2 × 2·106 | LT1167 I.A. | P |
[139] | ZnO | 20.33 μA·mM−1·cm−2 | 0.5–10 | nr | nr | nr | Ag/AgCl | nr | CD4007UB | P |
[140] | ZnO nanorods | nr | 0.01–5 | nr | nr | nr | Ag/AgCl | nr | Glass FET | P |
P, potentiometric; A, amperometric; I.A., instrumentation amplifier; nr, not reported; PPI/NiTsPc, poly(propylene imine) dendrimer/nickel tetrasulphonated phthalocyanine.
3.4. Calcium Ion Sensors
Calcium ions regulate a series of biological processes, such as cell proliferation, gene expression, and apoptosis, through bonding interactions with specific proteins, each one having a different affinity [141]. The proteins that bind with calcium are found both inside and outside of the living cells, although it acts as a “trigger” for the abovementioned processes [142]. Sensing nanostructures based on semiconductors offer advantages in terms of biocompatibility, time response, and miniaturization (see Table 5). Various materials have been used to realize sensing membranes for these sensors. For instance, zinc oxide was used for the realization of nanorod sensors, developed to measure the concentration of intra- and extracellular calcium ions [99,143,144]. These sensors, integrated on FETs with a separate extended gate, have been shown to be linear and sturdy [145].
Table 5.
Ref. | Sensitive Material | Sensitivity | Range | Linearity (%) | Reference Electrode | Sensitive Area (mm2) | FET Device |
---|---|---|---|---|---|---|---|
[146] | RuO2 | 32.5 mV/pCa | pCa0–pCa2 | 97.6 | Ag/AgCl | nr | NMOS |
[147] | Ru-doped TiO2 or RuO2 | 29.65 mV/pCa | pCa0–pCa3 | 99.9 | Ag/AgCl | nr | CD4007UB |
[148] | PVC | 25.02 mV/pCa | 0.001–1 mM | 99.65 | Ag/AgCl | nr | CD4007UB |
[149] | ZnO nanorods | 26.55 mV/decade | 0.001–100 mM | nr | Ag/AgCl | Π × 0.252 | nr |
PVC, polyvinyl chloride; nr, not reported.
3.5. DNA Sensors
Nucleic acid biosensors find wide application in the identification of pathogens, pharmaceutical screening, and the diagnosis of genetic diseases, as well as virus and tumor cell detection. The working principle of these sensors is based on the specific recognition of a single short chain of nucleic acids that hybridizes with a complementary DNA/RNA strand. FET technology for acid nucleic detection is mostly characterized by sensing membranes capable of amplifying the events of nucleic acid hybridization. For instance, an EGFET device with an Au nanoporous membrane has been recently proposed for the evaluation of Staphylococcus aureus 16S rRNA (see Figure 4). The presence of this membrane gives the device high linearity, a broad dynamic range (from 101 pM to 106 pM), and a limit of detection of ~1 pM [150]. Sensing membranes based on nanowires and nanofilms have been investigated recently as a part of an extended-gate device. Gallium nitride (GaN) was used because of its biocompatibility and nontoxicity. Both biosensors exhibited high selectivity and rapid detection, although those fabricated with nanowires were more sensitive, showing a wide dynamic range (from 10−19 to 10−6 M) [151].
3.6. Immunosensors
Immunosensors belong to a class of biosensors based on antigen–antibody interactions in biological fluids, a well-recognized and consolidated technology in the field of clinical diagnostics. These biosensors are also used in applications in environmental pollution and food safety when the analytes is a microorganism such as a bacterium, virus, or herbicide. Recently, an immunosensor has been developed and characterized using SEGFET technology for the detection of dengue virus nonstructural protein 1 (NS1) [152]. This sensor consists of the previously discussed separate extended-gate terminal (gold electrode), modified with anti-NS1 antibodies. This device has shown a linear current response for concentrations of less than 1 µg/mL with a detection limit of 0.25 µg/mL. The fabricated device and a similar one, which are reported in the most recent literature, suggest the possibility of using this biosensor as an alternative to the conventional techniques that require adequate instruments and trained personnel.
4. Discussion and Conclusions
This review intends to cover most of the recent developments in the field of EGFET-based bio/chemosensors while giving insights into the technological context within which they have been developed. Even though not exhaustive, the work is mainly focused on the solid-state devices used as interfaces of the electronic sensors, the technologies actually investigated for the sensitive layers, and the main related applications reported in the literature. Since the introduction of the first biosensors, such as ISFET and EGFET, the scientific community has been developing even more trustworthy sensing devices that are increasingly responsive to biological and chemical species. As highlighted in the previous sections, development of these devices is currently expanding thanks to the implementation of even more sophisticated nanotechnologies derived from electronics, physics, and materials science. This class of sensors, particularly the potentiometric devices using FET technology, are more easily miniaturized as compared to other types of biosensors (optical, thermal, etc.), justifying the strong scientific interest in the field of biomedical research. In general, the use of FETs allows low-cost transduction of biological information by means of a specific interaction between the sensitive element and the analyte, avoiding cumbersome and complex instruments and reducing chemical reagents and specific markers (label-free). Van der Spiegel highlighted the important points concerning the development of a new class of monolithic sensors utilizing novel FET devices, including the fabrication of a sensitive layer with high specificity for the desired chemical species, placed separately from the transistor to avoid possible damage caused by the surrounding chemical environment. This is what the rapid deterioration of the semiconductor material springs from, along with the resulting problems. In current scientific literature, the terms EGFET and SEGFET involve two different modes of approaching the development of electrochemical biosensors for the detection of analytes. As previously highlighted, since their development, one of the most interesting features of EGFET bio/chemosensors was the possibility of monitoring the binding of species of interest by a direct change in the electrical property of the device. Consequently, an important aspect in the development of high-performance EGFET sensors concerns the selectivity of the device, which allows the detection of analytes while avoiding interference. The selective detection of analytes avoiding contributions from undesired chemical species is a less mentioned but still hot research topic, which is mainly limited by the properties of the interface between the chemical environment and the sensitive layer. The most recent literature reports comprehensive reviews (to refer to for in-depth insights) focused on the engineering of sensitive layers for the production of new biomolecules with tailor-designed properties as a strategy for improving the analytical performance of EGFET [153,154].
Over the years, most of the efforts have been focused on the possibility of applying materials (often insulating materials) in the field of ion sensing, which established well-defined design criteria, from the more classic metal/metal oxide electrodes to the more recent nanostructured materials, not neglecting the use of different materials such as paper [30,32,41,42,113,114,115,116,117,136,137,138,139,140,141,142,143,144,145,146,147,148,149,150,151,152,155,156,157]. Although the literature reports different attempts to improve the performance of EGFETs, mainly acting on high aspect ratio, reduced leakage current, and parasitic capacitance, many devices are based on commercial FET, as reported in Table 6, which highlights how the development of EGFET sensors over the years has preferred the use of off-the-shelf components because of the easier fabrication process and lower cost. Though off-the-shelf components ensure easier and faster sensor development, a custom electronic interface can improve the overall performance of the EGFET biosensor (e.g., noise, sensitivity, power consumption) for different specific applications.
Table 6.
Refs. | FET Device | Model | CMOS Process (µm) | Main Features | W/L (µm/µm) |
---|---|---|---|---|---|
[158] | NC | N/A | nr | SOI-FET working in parasitic Bipolar Junction Transistor (BJT) operation method | nr |
[159] | NC | N/A | 0.5 | CMOS–DPDM n–well | 600/20 |
[30,32,42,92,94,101,104,105,113,114,117,139,147,148,160,161,162,163,164,165,166,167] | C | CD4007UB | nr | CMOS dual complementary pair plus inverter | nr |
[41,168,169] | C | NDP6060L | nr | n–Channel logic level enhancement mode FET | nr |
[170,171] | C | HEF4007 | nr | Dual complementary pair and inverter | nr |
[172] | C | BS170 | nr | n−Channel MOSFET | 9700/2 |
[173] | NC | N/A | 0.16 | Differential source follower | 8/2 |
[174] | NC | N/A | 0.35 | Rectangular p-type MOSFET | 18/1 |
[175] | NC | N/A | 0.6 | Pt and Au gate MOSFET | 100/10 |
[95,108,109,138] | C | LT1167 | nr | Instrumentation amplifier | nr |
[176] | C | 2SK246Y | nr | n-Channel junction FET | nr |
C, commercial FET device; NC, noncommercial FET device; DPDM, double poly double metal; nr, not reported; N/A, not applicable.
As far as pH sensors are concerned, sensitivity does not show significant changes in the reviewed literature, ranging from 45 mV/pH for ZnO nanorod layer [106] to 62.87 mV/pH for the most expensive PdO sensing element [113]. The problem of threshold voltage drift seems to represent a bottleneck ranging from 0.04 mV/h [36] to 13.2 mV/h [92]. On the other hand, the sensitivity of urea and glucose sensors based on EGFET is mostly affected by the sensitive layer leading to a high range of variability. There are many interesting applications and opportunities for the successful development of EGFET-based bio/chemosensors, such as drug discovery, clinical diagnosis of diseases, biomedicine, food safety and processing, environmental monitoring, etc. [51,89,90,177,178]. In particular, the development of disposable and portable detection systems is often preferred over sensitive laboratory-based techniques. Interesting examples are continuous glucose monitoring in diabetic patients, remote sensing of airborne bacteria in counter-bioterrorist activities, and routine monitoring of analytical parameters. In addition, the detection of specific DNA sequences and the study of gene polymorphisms are fundamental to the rapid detection of genetic mutations and sequencing of the genome, offering the possibility of performing a reliable diagnosis even before any disease symptoms appear. Apart from this positive note, very stringent laboratory standards, guidelines, and regulations require that EGFET development should strongly fit the specific demand. Increasing efforts in FET design could be a key point in making a significant contribution to the development of EGFET-based chemical sensors, which could be one reason for industry to invest in more reliable chemical sensors.
Funding
The APC was funded by University Magna Græcia of Catanzaro, Department of Health Sciences
Conflicts of Interest
The authors declare no conflict of interest.
References
- 1.Bergveld P. Development of an Ion–Sensitive Solid–State Device for Neurophysiological Measurements. IEEE Trans. Biomed. Eng. 1970;17:70–71. doi: 10.1109/TBME.1970.4502688. [DOI] [PubMed] [Google Scholar]
- 2.Luz R.A.S., Rodrigo M., Crespilho I., Crespilho F.N. Nanobioelectrochemistry: From Implantable Biosensors to Green Power Generation. Springer; Berlin/Heidelberg, Germany: 2013. Nanomaterials for Biosensors and Implantable Biodevices; pp. 27–28. [Google Scholar]
- 3.Van der Spiegel J., Lauks I., Chan P., Babic D. The extended gate chemically sensitive field effect transistor as multi–species microprobe. Sens. Actuators. 1983;4:291–298. doi: 10.1016/0250-6874(83)85035-5. [DOI] [Google Scholar]
- 4.Batista P.D., Mulato M. ZnO extended-gate field-effect transistors as pH sensors. Appl. Phys. Lett. 2005;87:143508. doi: 10.1063/1.2084319. [DOI] [Google Scholar]
- 5.Lauks I., Van der Spiegel J. Integrated Ambient Sensing Devices and Methods of Manufacture. US4,739,380A. U.S. Patent. 1984 Apr 19;
- 6.Van der Spiegel J., Lauks I., Wieck H., Dietz T., Zelin M., Turfa A. Electrochemical Microsensor Arrays for Biomedical Applications. Proc. SPIE Mirosens. Catheter-Based Imaging Technol. 1988;904:7–12. doi: 10.1117/12.945223. [DOI] [Google Scholar]
- 7.Schöning M.J., Poghossian A. Bio FEDs (Field-Effect Devices): State-of-the-art and new directions. Electroanalysis. 2006;18:1893–1900. doi: 10.1002/elan.200603609. [DOI] [Google Scholar]
- 8.Pijanowska D.G., Torbicz W. pH-ISFET based urea biosensor. Sens. Actuators B Chem. 1997;44:370–376. doi: 10.1016/S0925-4005(97)00194-9. [DOI] [Google Scholar]
- 9.Pan T.-M., Huang M.-D., Lin C.-W., Wu M.-H. Development of high-κ HoTiO3 sensing membrane for pH detection and glucose biosensing. Sens. Actuators B Chem. 2010;144:139–145. doi: 10.1016/j.snb.2009.10.049. [DOI] [Google Scholar]
- 10.Lin Y.-H., Wang S.-H., Wu M.-H., Pan T.-M., Lai C.-S., Luo J.-D., Chiou C.-C. Integrating solid-state sensor and microfluidic devices for glucose, urea and creatinine detection based on enzyme-carrying alginate microbeads. Biosens. Bioelectron. 2013;43:328–335. doi: 10.1016/j.bios.2012.12.053. [DOI] [PubMed] [Google Scholar]
- 11.Hideshima S., Sato R., Kuroiwa S., Osaka T. Fabrication of stable antibody–modified field effect transistors using electrical activation of Schiff base cross-linkages for tumor marker detection. Biosens. Bioelectron. 2011;26:2419–2425. doi: 10.1016/j.bios.2010.10.023. [DOI] [PubMed] [Google Scholar]
- 12.Selvanayagam Z.E., Neuzil P., Gopalakrishnakone P., Sridhar U., Singh M., Ho L.C. An ISFET-based immunosensor for the detection of β-bungarotoxin. Biosens. Bioelectron. 2002;17:821–826. doi: 10.1016/S0956-5663(02)00075-1. [DOI] [PubMed] [Google Scholar]
- 13.Fiorillo A.S., Van Der Spiegel J., Bloomfield P.E., Esmail-Zandi D. A P(VDF-TrFE)-based Integrated Ultrasonic Transducer. Sens. Actuators A Phys. 1990;22:719–725. doi: 10.1016/0924-4247(89)80065-2. [DOI] [Google Scholar]
- 14.Van der Spiegel J., Fiorillo A.S. Method of Manufacturing Ferroelectric MOSFET Sensors. US5,254,504A. U.S. Patent. 1989 Oct 19;
- 15.Sung M., Shin K., Moon W. A micro-machined hydrophone employing a piezoelectric body combined on the gate of a field-effect transistor. Sens. Actuators A Phys. 2016;237:155–166. doi: 10.1016/j.sna.2015.11.025. [DOI] [Google Scholar]
- 16.Lambrechts M., Sansen W. Biosensors: Microelectrochemical Devices. Institute of Physics Publishing; Bristol, UK: 1992. [Google Scholar]
- 17.Valdes Zaldivar E., Lastres Capote A., Horna C.D., Arias de Fuentes O. Estudio de la deriva del isfet utilizando instrumentaciòn virtual; Proceedings of the XI IBERCHIP Workshop; Salvador de Bahía, Brazil. 28–30 March 2005. [Google Scholar]
- 18.Kaisti M. Detection principles of biological and chemical FET sensors. Biosens. Bioelectron. 2017;98:437–448. doi: 10.1016/j.bios.2017.07.010. [DOI] [PubMed] [Google Scholar]
- 19.Poghossian A.S. Method of Fabrication of ISFETs and CHEMFETs on an Si-SiO2-Si Structure. Sens. Actuators B Chem. 1993;14:653–654. doi: 10.1016/0925-4005(93)85130-3. [DOI] [Google Scholar]
- 20.Codinachs L.M.I., Baldi A., Merlos A., Abramova N., Ipatov A., Jimenez-Jorquera C., Bratov A. Integrated Multisensor for FIA-Based Electronic Tongue Applications. IEEE Sens. J. 2008;8:608–615. doi: 10.1109/JSEN.2008.918965. [DOI] [Google Scholar]
- 21.Kimura J., Kuriyama T., Kawana Y. An integrated SOS/FET multi-biosensor. Sens. Actuators. 1986;9:373–387. doi: 10.1016/0250-6874(86)80069-5. [DOI] [Google Scholar]
- 22.Cane C., Gracia I., Merlos A. Microtechnologies for pH ISFET Chemical Sensors. Microelectron. J. 1997;28:389–405. doi: 10.1016/S0026-2692(96)00068-7. [DOI] [Google Scholar]
- 23.Ho N.J., Kratochvil J., Blackburn G.F., Janata J. Encapsulation of polymeric membrane-based ion-selective field effect transistor. Sens. Actuators. 1983;4:413–421. doi: 10.1016/0250-6874(83)85052-5. [DOI] [Google Scholar]
- 24.Van Der Schoot B.H., Van Den Vlekkert H.H., De Rooij N.F., Van Den Berg A., Grisel A. A flow injection analysis system with glass-bonded ISFETs for the simultaneous detection of calcium and potassium ions and pH. Sens. Actuators B Chem. 1991;4:239–241. doi: 10.1016/0925-4005(91)80116-2. [DOI] [Google Scholar]
- 25.Hsiung S.S.K., Chou J.C., Sun T.P., Chung W.Y., Chin Y.L., Ce L.Z. Method for Fabricating a Titanium Nitride Sensing Membrane on an EGFET. US6974716B2. U.S. Patent. 2005 Dec 13;
- 26.Mokhtarifar N., Goldschmidtboeing F., Woias P. Low-cost EGFET-based pH-sensor using encapsulated ITO/PET-electrodes; Proceedings of the 2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC); Houston, TX, USA. 14–17 July 2018. [Google Scholar]
- 27.Lin Y.H., Chu C.P., Lin C.F., Liao H.H., Tsai H.H., Juang Y.Z. Extended-gate field-effect transistor packed in micro channel for glucose, urea and protein biomarker detection. Biomed. Microdevices. 2015;17:111. doi: 10.1007/s10544-015-0020-4. [DOI] [PubMed] [Google Scholar]
- 28.Yao P.-C., Chiang J.L., Lee M.-C. Application of sol–gel TiO2 film for an extended-gate H+ ion-sensitive field-effect transistor. Solid State Sci. 2014;28:47–54. doi: 10.1016/j.solidstatesciences.2013.12.011. [DOI] [Google Scholar]
- 29.Kwon I., Lee H.-H., Choi J., Shin J.-K., Seo S.-H., Choi S.-W., Chun H.-S. Extended-Gate metal oxide semiconductor field effect transistor–based biosensor for detection of deoxynivalenol. Jpn. J. Appl. Phys. 2011;50:06GL08. doi: 10.7567/JJAP.50.06GL08. [DOI] [Google Scholar]
- 30.Yin L.T., Chou J.C., Chung W.Y., Sun T.P., Hsiung S.K. Study of indium tin oxide thin film for separative extended gate ISFET. Mater. Chem. Phys. 2001;70:12–16. doi: 10.1016/S0254-0584(00)00373-4. [DOI] [Google Scholar]
- 31.Fayroz A., Sabah N.M., Ahmed Z., Hassan M.A.A. Effect of light on the sensitivity of CuS thin film EGFET implemented as pH sensor. Int. J. Electrochem. Sci. 2016;11:4380–4388. doi: 10.20964/2016.06.51. [DOI] [Google Scholar]
- 32.Chi L.-L., Chou J.-C., Chung W.-Y., Sun T.-P., Hsiung S.-K. Study on extended gate field effect transistor with tin oxide sensing membrane. Mater. Chem. Phys. 2000;63:19–23. doi: 10.1016/S0254-0584(99)00184-4. [DOI] [Google Scholar]
- 33.Cheng N.J., Yang C.F., Lo Y.P. Investigation of extended-gate field-effect transistor pH sensors based on different temperature-annealed bi-layer MWCNTs-In2O3 films. Nanoscale Res. Lett. 2014;9:1–8. doi: 10.1186/1556-276X-9-502. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Brouk I., Nemirovsky Y. l/f noise in CMOS transistors for analog applications; Proceedings of the 21st IEEE Convention of the Electrical and Electronic Engineers in Israel; Tel-Aviv, Israel. 11–12 April 2001. [Google Scholar]
- 35.Francis S.A., Dasgupta A., Fleetwood D.M. Effects of total dose irradiation on the gate-voltage dependence of the 1/f noise of nMOS and pMOS transistors. IEEE Trans. Electron Devices. 2010;57:503–510. doi: 10.1109/TED.2009.2036297. [DOI] [Google Scholar]
- 36.Tedja S., Van Der Spiegel J., Williams H.H. Analytical and Experimental Studies of Thermal Noise in MOSFET’s. IEEE Trans. Electron Devices. 1994;41:2069–2075. doi: 10.1109/16.333824. [DOI] [Google Scholar]
- 37.Kaisti M., Alexandrovna Boeva Z., Koskinen J., Nieminen S., Bobacka J., Levon K. Hand-held transistor based electrical and multiplexed chemical sensing system. ACS Sens. 2016;1:1423–1431. doi: 10.1021/acssensors.6b00520. [DOI] [Google Scholar]
- 38.Brews J.R., Fichtner W., Nicollian E.H., Sze S.M. Generalized guide for MOSFET miniaturization. IEEE Electron Device Lett. 1980;1:2–4. doi: 10.1109/EDL.1980.25205. [DOI] [Google Scholar]
- 39.Chi Y., Maier C., Cauwenberghs G. Ultra-high input impedance, low noise integrated amplifier for noncontact biopotential sensing. IEEE Trans. Emerg. Sel. Top. Circuits Syst. 2011;1:526–535. doi: 10.1109/JETCAS.2011.2179419. [DOI] [Google Scholar]
- 40.Poghossian A., Yoshinobu T., Simonis A., Ecken H., Luth H., Schoning M.J. Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? Sens. Actuators B Chem. 2001;78:237–242. doi: 10.1016/S0925-4005(01)00819-X. [DOI] [Google Scholar]
- 41.Yusof K.A., Rahman R.A., Zulkefle M.A., Herman S.H., Abdullah W.F.H. EGFET pH sensor performance dependence on sputtered TiO2 sensing membrane deposition temperature. J. Sens. 2016 doi: 10.1155/2016/7594531. [DOI] [Google Scholar]
- 42.Guerra E.M., Ribeiro Silva G., Mulato M. Extended gate field effect transistor using V2O5 xerogel sensing membrane by sol–gel method. Solid State Sci. 2009;11:456–460. doi: 10.1016/j.solidstatesciences.2008.07.014. [DOI] [Google Scholar]
- 43.Magee A. Fabrication and design of EGFET devices for biosensing; Proceedings of the NNIN REU Research Accomplishments; Ithaca, NY, USA. 9–12 August 2015. [Google Scholar]
- 44.Rajan N.K., Brower K., Duan X., Reed M.A. Limit of detection of field effect transistor biosensors: Effects of surface modification and size dependence. Appl. Phys. Lett. 2014;104:084106. doi: 10.1063/1.4867025. [DOI] [Google Scholar]
- 45.Chang Z.Y., Sansen W. Test structure for evaluation of 1/f noise in CMOS technologies. Proc. Int. Conf. Microelectron. Test Struct. 1989;2:143–146. doi: 10.1109/icmts.1989.39299. [DOI] [Google Scholar]
- 46.Liu Y., Duan X., Huang Y., Duan X. Two-dimensional transistors beyond graphene and TMDCs. Chem. Soc. Rev. 2018;47:6388–6409. doi: 10.1039/C8CS00318A. [DOI] [PubMed] [Google Scholar]
- 47.Ho C., Yu H.-Z. Aptamer-based electrochemical biosensors for the detection of small molecules and plasma proteins. In: Marinesco S., Dale N., editors. Microelectrode Biosensors. Neuromethods. Volume 80. Humana Press; Totowa, NJ, USA: 2013. pp. 319–346. [Google Scholar]
- 48.Karadurmus L., Kurbanoglu S., Uslu B., Ozkan S.A. Electrochemical DNA biosensors in drug analysis. Curr. Pharm. Anal. 2016;12:195–207. doi: 10.2174/1573412912666160422152634. [DOI] [Google Scholar]
- 49.Plumeré N., Henig J., Campbell W.H. Enzyme-catalyzed O2 removal system for electrochemical analysis under ambient air: Application in an amperometric nitrate biosensor. Anal. Chem. 2012;84:2141–2146. doi: 10.1021/ac2020883. [DOI] [PubMed] [Google Scholar]
- 50.Cizek K., Prior C., Thammakhet C., Galik M., Linker K., Tsui R., Cagan A., Wake J., La Belle J., Wang J. Integrated explosive preconcentrator and electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vapor. Anal. Chim. Acta. 2010;66:117–121. doi: 10.1016/j.aca.2009.12.008. [DOI] [PubMed] [Google Scholar]
- 51.Zeng Y., Zhu Z., Du D., Lin Y. Nanomaterial–based electrochemical biosensors for food safety. J. Electroanal. Chem. 2016;781:147–154. doi: 10.1016/j.jelechem.2016.10.030. [DOI] [Google Scholar]
- 52.Guth U., Vonau W., Zosel J. Recent developments in electrochemical sensor application and technology—A review. Meas. Sci. Technol. 2009;20:042002. doi: 10.1088/0957-0233/20/4/042002. [DOI] [Google Scholar]
- 53.Simić M., Manjakkal L., Zaraska K., Stojanović G.M., Dahiya R. TiO2 Based Thick Film pH Sensor. IEEE Sens. J. 2017;17:248–255. doi: 10.1109/JSEN.2016.2628765. [DOI] [Google Scholar]
- 54.Bratov A., Abramova N., Ipatov A. Recent trends in potentiometric sensor arrays—A review. Anal. Chim. Acta. 2010;678:149–159. doi: 10.1016/j.aca.2010.08.035. [DOI] [PubMed] [Google Scholar]
- 55.Adibi M., Pirali-Hamedani M., Norouzi P. Copper nano-composite potentiometric sensor. Int. J. Electrochem. Sci. 2011;6:717–726. doi: 10.1007/s13738-014-0406-x. [DOI] [Google Scholar]
- 56.Zhang Q., Majumdar H.S., Kaisti M., Prabhu A., Ivaska A., Österbacka R., Rahman A., Levon K. Surface functionalization of ion-sensitive floating-gate field effect transistors with organic electronics. IEEE Trans. Electron Devices. 2015;62:1291–1298. doi: 10.1109/TED.2015.2396996. [DOI] [Google Scholar]
- 57.Guan W., Rajan N.K., Duan X., Reed M.A. Quantitative probing of surface charges at dielectric-electrolyte interfaces. Lab Chip. 2015;13:1431–1436. doi: 10.1039/c3lc41351a. [DOI] [PubMed] [Google Scholar]
- 58.Shinwari M.W., Zhitomirsky D., Deen I.A., Selvaganapathy P.R., Deen M.J., Landheer D. Microfabricated Reference Electrodes and their Biosensing Applications. Sensors. 2010;10:1679–1715. doi: 10.3390/s100301679. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Song M.J., Hwang S.W., Whang D. Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires. J. Appl. Electrochem. 2010;40:2099–2105. doi: 10.1007/s10800-010-0191-x. [DOI] [Google Scholar]
- 60.Palanisamy S., Karuppiah C., Chen S.M., Periakaruppan P. A highly sensitive and selective enzymatic biosensor based on direct electrochemistry of hemoglobin at zinc oxide nanoparticles modified activated screen printed carbon electrod. Electroanalysis. 2014;26:1984–1993. doi: 10.1002/elan.201400304. [DOI] [Google Scholar]
- 61.Li Y., Li Y., Yang Y. A new amperometric H2O2 biosensor based on nanocomposite films of chitosan-MWNTs, hemoglobin, and silver nanoparticles. J. Solid State Electrochem. 2012;16:1133–1140. doi: 10.1007/s10008-011-1503-8. [DOI] [Google Scholar]
- 62.Fang Y., Guo S., Zhu C., Zhai Y., Wang E. Self-assembly of cationic polyelectrolyte-functionalized graphene nanosheets and gold nanoparticles: A two-dimensional heterostructure for hydrogen peroxide sensing. Langmuir. 2010;26:11277–11282. doi: 10.1021/la100575g. [DOI] [PubMed] [Google Scholar]
- 63.Wang J., Musameh M., Lin Y. Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors. J. Am. Chem. Soc. 2003;125:2408–2409. doi: 10.1021/ja028951v. [DOI] [PubMed] [Google Scholar]
- 64.Yang P., Wang L., Wu Q., Chen Z., Lin X. A method for determination of glucose by an amperometric bienzyme biosensor based on silver nanocubes modified Au electrode. Sens. Actuator B Chem. 2014;194:71–78. doi: 10.1016/j.snb.2013.12.074. [DOI] [Google Scholar]
- 65.Sharma A., Kumar A. Study of structural and electro-catalytic behaviour of amperometric biosensor based on chitosan/polypyrrole nanotubes–gold nanoparticles nanocomposites. Synth. Met. 2016;220:551–559. doi: 10.1016/j.synthmet.2016.07.012. [DOI] [Google Scholar]
- 66.Lin J., He C., Zhao Y., Zhang S. One-step synthesis of silver nanoparticles/carbon nanotubes/chitosan film and its application in glucose biosensor. Sens. Actuators B Chem. 2009;137:768–773. doi: 10.1016/j.snb.2009.01.033. [DOI] [Google Scholar]
- 67.Song M.J., Kim J.H., Lee S.K., Lim D.S., Hwang S.W., Whang D. Analytical characteristics of electrochemical biosensor using pt-dispersed graphene on boron doped diamond electrode. Electroanalysis. 2011;23:2408–2414. doi: 10.1002/elan.201100265. [DOI] [Google Scholar]
- 68.Al Mamun K.A., Islam S.K., Hensley D.K., McFarlane N. A glucose biosensor using CMOS potentiostat and vertically aligned carbon nanofibers. IEEE Trans. Biomed. Circuits Syst. 2016;10:807–816. doi: 10.1109/TBCAS.2016.2557787. [DOI] [PubMed] [Google Scholar]
- 69.Yu Y., Al Mamun K.A., Shanta A.S., Islam S.K., McFarlane N. Vertically aligned carbon nanofibers as a cell impedance sensor. IEEE Trans. Nanotechnol. 2016;15:856–861. doi: 10.1109/TNANO.2016.2558102. [DOI] [Google Scholar]
- 70.Islam A.B., Islam S.K., Rahman T. A highly selective mediator less glucose detector employing vertically aligned carbon nanofiber (VACNF); Proceedings of the 2010 IEEE Sensors; Kona, HI, USA. 1–4 November 2010. [Google Scholar]
- 71.Al Mamun K.A., Gu J., Hensley D.K., Islam S.K., McFarlane N. Integration of carbon nanostructures on CMOS for lab-on-a-chip sensing; Proceedings of the 2016 IEEE International Symposium on Circuits and Systems (ISCAS); Montreal, QC, Canada. 22–25 May 2016; pp. 2879–2882. [DOI] [Google Scholar]
- 72.Islam S.K., Mahbub I., Shamsir S. Carbon nanomaterial based sensors for astrobiology exploration; Proceedings of the 2017 IEEE 60th International Midwest Symposium on Circuits and Systems (MWSCAS); Boston, MA, USA. 6–9 August 2017. [Google Scholar]
- 73.Piao Y., Han D.J., Seo T.S. Highly conductive graphite nanoparticle based enzyme biosensor for electrochemical glucose detection. Sens. Actuators B Chem. 2014;194:454–459. doi: 10.1016/j.snb.2013.12.045. [DOI] [Google Scholar]
- 74.Adeloju S.B., Hussain S. Potentiometric sulfite biosensor based on entrapment of sulfite oxidase in a polypyrrole film on a platinum electrode modified with platinum nanoparticles. Microchim. Acta. 2016;183:1341–1350. doi: 10.1007/s00604-016-1748-0. [DOI] [Google Scholar]
- 75.Pal R.K., Kundu S.C., Yadavalli V.K. Biosensing using photolithographically micropatterned electrodes of PEDOT:PSS on ITO substrates. Sens. Actuators B Chem. 2017;242:140–147. doi: 10.1016/j.snb.2016.11.049. [DOI] [Google Scholar]
- 76.Chauhan N., Rawal R., Hooda V., Jain U. Electrochemical biosensor with graphene oxide nanoparticles and polypyrrole interface for the detection of bilirubin. RSC Adv. 2016;6:63624–63633. doi: 10.1039/C6RA15671A. [DOI] [Google Scholar]
- 77.Shi K., Shiu K.K. Scanning tunneling microscopic and voltammetric studies of the surface structures of an electrochemically activated glassy carbon electrode. Anal. Chem. 2002;74:879–885. doi: 10.1021/ac010734+. [DOI] [PubMed] [Google Scholar]
- 78.Zehani N., Fortgang P., Saddek Lachgar M., Baraket A., Arab M., Dzyadevych S.V., Kherrat R., Jaffrezic-Renault N. Highly sensitive electrochemical biosensor for bisphenol A detection based on a diazonium-functionalized boron doped diamond electrode modified with a multi-walled carbon nanotube-tyrosinase hybrid film. Biosens. Bioelectron. 2015;74:830–835. doi: 10.1016/j.bios.2015.07.051. [DOI] [PubMed] [Google Scholar]
- 79.Braik M., Barsan M.M., Dridi C., Ben Ali M., Brett C.M.A. Highly sensitive amperometric enzyme biosensor for detection of superoxide based on conducting polymer/CNT modified electrodes and superoxide dismutase. Sens. Actuators B Chem. 2016;236:574–582. doi: 10.1016/j.snb.2016.06.032. [DOI] [Google Scholar]
- 80.Malhotra B.D., Chaubey A. Biosensors for clinical diagnostics industry. Sens. Actuators B Chem. 2003;91:117–127. doi: 10.1016/S0925-4005(03)00075-3. [DOI] [Google Scholar]
- 81.Harguindey S., Pedraz J.L., Garcia Canero R., Perez de Diego J., Cragoe E.J. Hydrogen ion-dependent oncogenesis and parallel new avenues to cancer prevention and treatment using a H(+)-mediated unifying approach: PH-related and pH-unrelated mechanisms. Crit. Rev. Oncog. 1995;6:1–34. doi: 10.1615/CritRevOncog.v6.i1.20. [DOI] [PubMed] [Google Scholar]
- 82.Gottlieb R.A., Dosanjh A. Mutant cystic fibrosis transmembrane conductance regulator inhibits acidification and apoptosis in C127 cells: Possible relevance to cystic fibrosis. Proc. Natl. Acad. Sci. USA. 1996;6:3587–3591. doi: 10.1073/pnas.93.8.3587. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83.Miksa M., Komura H., Wu R., Shah K.G., Wang P. A novel method to determine the engulfment of apoptotic cells by macrophages using phrodo succinimidyl ester. J. Immunol. Methods. 2009;342:71–77. doi: 10.1016/j.jim.2008.11.019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84.Lakadamyali M., Rust M.J., Babcock H.P., Zhuang X. Visualizing infection of individual influenza viruses. Proc. Natl. Acad. Sci. USA. 2013;100:9280–9285. doi: 10.1073/pnas.0832269100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Fog A., Buck R.P. Electronic semiconducting oxides as pH sensors. Sens. Actuators. 1984;5:137–146. doi: 10.1016/0250-6874(84)80004-9. [DOI] [Google Scholar]
- 86.Siqueira J.R., Fernandes E.G.R., de Oliveira O.N., Zucolotto V. Biosensors Based on Field-Effect Devices. In: Crespilho F., editor. Nanobioelectrochemistry. Springer; Berlin/Heidelberg, Germany: 2013. [Google Scholar]
- 87.Al-Hardan N.H., Hamid M.A.A., Ahmed N.M., Jalar A., Shamsudin R., Othman N.K., Keng L.K., Chiu W., Al-Rawi H.N. High sensitivity pH sensor based on porous silicon (PSi) extended gate field-effect transistor. Sensors. 2016;16:839. doi: 10.3390/s16060839. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88.Sabah F.A., Ahmed N.M., Hassan Z., Almessiere M.A., Al-hardan N.H. Sensitivity of CuS membrane pH sensor with and without MOSFET. JOM. 2017;69:1134–1142. doi: 10.1007/s11837-016-2165-x. [DOI] [Google Scholar]
- 89.Banna M.H., Najjaran H., Sadiq R., Imran S.A., Rodriguez M.J., Hoorfar M. Miniaturized Water Quality Monitoring pH and Conductivity Sensors. Sens. Actuators B Chem. 2014;193:434–441. doi: 10.1016/j.snb.2013.12.002. [DOI] [Google Scholar]
- 90.Bohnke C., Duroy H., Fourquet J.-L. pH sensors with lithium lanthanum titanate sensitive material: Applications in food industry. Sens. Actuators B Chem. 2003;89:240–247. doi: 10.1016/S0925-4005(02)00473-2. [DOI] [Google Scholar]
- 91.Kwon D.-H., Cho B.-W., Kim C.-S., Sohn B.-K. Effects of heat treatment on Ta2O5 sensing membrane for low drift and high sensitivity pH-ISFET. Sens. Actuators B Chem. 1996;34:441–445. doi: 10.1016/S0925-4005(96)01938-7. [DOI] [Google Scholar]
- 92.Lue C.-E., Wang I.-S., Huang C.-H., Shiao Y.-T., Wang H.-C., Yang C.-M., Hsu S.H., Chang C.Y., Wang W., Lai C.S. pH sensing reliability of flexible ITO/PET electrodes on EGFETs prepared by a roll-to-roll process. Microelectron. Reliab. 2012;52:1651–1654. doi: 10.1016/j.microrel.2011.10.026. [DOI] [Google Scholar]
- 93.Vieira N.C.S., Fernandes E.G.R., de Queiroz A.A.A., Guimarães F.E.G., Zucolotto V. Indium tin oxide synthesized by a low cost route as SEGFET pH sensor. Mater. Res. 2013;16:1156–1160. doi: 10.1590/S1516-14392013005000101. [DOI] [Google Scholar]
- 94.Yang C.-M., Wang I.-S., Lin Y.-T., Huang C.-H., Lu T.-F., Lue C.-E., Pijanowska D.G., Hua M.-Y., Lai C.-S. Low cost and flexible electrodes with NH3 plasma treatments in extended gate field effect transistors for urea detection. Sens. Actuators B Chem. 2013;187:274–279. doi: 10.1016/j.snb.2012.11.023. [DOI] [Google Scholar]
- 95.Chen J.-C., Chou J.-C., Sun T.-P., Hsiung S.-K. Portable urea biosensor based on the extended-gate field effect transistor sensor. Sens. Actuators B Chem. 2003;91:180–186. doi: 10.1016/S0925-4005(03)00161-8. [DOI] [Google Scholar]
- 96.Pan C.-W., Chou J.-C., Sun T.-P., Hsiung S.-K. Development of the tin oxide pH electrode by the sputtering method. Sens. Actuators B Chem. 2005;108:863–869. doi: 10.1016/j.snb.2004.11.033. [DOI] [Google Scholar]
- 97.Nguyen T.N.T., Seol Y.G., Lee N.-E. Organic field–effect transistor with extended indium tin oxide gate structure for selective pH sensing. Org. Electron. 2011;12:1815–1821. doi: 10.1016/j.orgel.2011.07.009. [DOI] [Google Scholar]
- 98.Kao C.-H., Chen H., Kuo L.-T., Wang J.-C., Chen Y.-T., Chu Y.-C., Chen C.-Y., Lai C.-S., Chang S.W., Chang C.W. Multi-analyte biosensors on a CF4 plasma treated Nb2O5-based membrane with an extended gate field effect transistor structure. Sens. Actuators B Chem. 2014;194:419–426. doi: 10.1016/j.snb.2013.12.056. [DOI] [Google Scholar]
- 99.Asif M.H., Nur O., Willander M., Danielsson B. Selective calcium ion detection with functionalized ZnO nanorods-extended gate MOSFET. Biosens. Bioelectron. 2009;24:3379–3382. doi: 10.1016/j.bios.2009.04.011. [DOI] [PubMed] [Google Scholar]
- 100.Fathil M.F.M., Arshad Md M.K., Ruslinda A.R., Gopinath S.C.B., Nuzaihan Md Nor M., Adzhri R., Hashim U., Lam H.Y. Substrate-gate coupling in ZnO-FET biosensor for cardiac troponin I detection. Sens. Actuators B Chem. 2017;242:1142–1154. doi: 10.1016/j.snb.2016.09.131. [DOI] [Google Scholar]
- 101.Wang J.-L., Yang P.-Y., Hsieh T.-Y., Juan P.-C. Ionic pH and glucose sensors fabricated using hydrothermal ZnO nanostructures. Jpn. J. Appl. Phys. 2015;55:01AE16. doi: 10.7567/JJAP.55.01AE16. [DOI] [Google Scholar]
- 102.Liao Y.-H., Chou J.-C. Preparation and characterization of the titanium dioxide thin films used for pH electrode and procaine drug sensor by sol–gel method. Mater. Chem. Phys. 2009;114:542–548. doi: 10.1016/j.matchemphys.2008.10.014. [DOI] [Google Scholar]
- 103.Chou J.C., Tzeng D.J. Study on the characteristics of the ruthenium oxide pH electrode. Rare Met. Mater. Eng. 2006;35:603–612. doi: 10.1016/j.snb.2007.07.023. [DOI] [Google Scholar]
- 104.Wu Y.-C., Wu S.-J., Lin C.-H. High performance EGFET-based pH sensor utilizing low-cost industrial-grade touch panel film as the gate structure. IEEE Sens. J. 2015;15:6279–6286. doi: 10.1109/JSEN.2015.2455057. [DOI] [Google Scholar]
- 105.Tsai C.-N., Chou J.-C., Sun T.-P., Hsiung S.-K. Study on the sensing characteristics and hysteresis effect of the tin oxide pH electrode. Sens. Actuators B Chem. 2005;108:877–882. doi: 10.1016/j.snb.2004.11.050. [DOI] [Google Scholar]
- 106.Qi J., Zhang H., Ji Z., Xu M., Zhang Y. ZnO nano-array-based EGFET biosensor for glucose detection. Appl. Phys. A. 2015;119:807–811. doi: 10.1007/s00339-015-9122-3. [DOI] [Google Scholar]
- 107.Wang J.-L., Yang P.-Y., Hsieh T.-Y., Hwang C.-C., Juang M.-H. pH-sensing characteristics of hydrothermal Al-doped ZnO nanostructures. J. Nanomater. 2013;2013 doi: 10.1155/2013/152079. [DOI] [Google Scholar]
- 108.Chou J.-C., Wang Y.S. Biosensor, Method of Manufacturing Sensing Unit Thereof, and Measuring System. 20040256685A1. U.S. Patent. 2004 Dec 23;
- 109.Yin L.-T., Wang H.-Y., Lin Y.-C., Huang W.-C. A novel instrumentation circuit for electrochemical measurements. Sensors. 2012;12:9687–9696. doi: 10.3390/s120709687. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 110.Sun C., Zeng R., Zhang J., Qiu Z.-J., Wu D. Effects of UV-ozone treatment on sensing behaviors of EGFETs with Al2O3 sensing film. Materials. 2017;10:1432. doi: 10.3390/ma10121432. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 111.Tarasov A., Wipf M., Stoop R.L., Bedner K., Fu W., Guzenko V.A., Knopfmacher O., Calame M., Schönenberger C. Understanding the electrolyte background for biochemical sensing with ion-sensitive field-effect transistors. ACS Nano. 2012;6:9291–9298. doi: 10.1021/nn303795r. [DOI] [PubMed] [Google Scholar]
- 112.Van Hal R.E.G., Eijkel J.C.T., Bergveld P. A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parameters. Sens. Actuators B Chem. 1995;24:201–205. doi: 10.1016/0925-4005(95)85043-0. [DOI] [Google Scholar]
- 113.Das A., Ko D.H., Chen C.-H., Chang L.-B., Lai C.-S., Chu F.-C., Chow L., Lin R.-M. Highly sensitive palladium oxide thin film extended gate FETs as pH sensor. Sens. Actuators B Chem. 2014;205:199–205. doi: 10.1016/j.snb.2014.08.057. [DOI] [Google Scholar]
- 114.Yang C.-M., Wang J.-C., Chiang T.-W., Lin Y.-T., Juan T.-W., Chen T.-C., Shih M.-Y., Lue C.-E., Lai C.-S. Hydrogen ion sensing characteristics of IGZO/Si electrode in EGFET. Int. J. Nanotechnol. 2014;11:15–26. doi: 10.1504/IJNT.2014.059806. [DOI] [Google Scholar]
- 115.Batista P.D. An embedded measurement system for electrical characterization of EGFET as pH sensor. Meas. Sci. Technol. 2013;25 doi: 10.1088/0957-0233/25/2/027001. [DOI] [Google Scholar]
- 116.Chien Y.-S., Tsai W.-L., Lee I.-C., Chou J.-C., Cheng H.-C. A novel pH sensor of extended-gate field-effect transistors with laser-irradiated carbon-nanotube network. IEEE Electron Device Lett. 2012;33:1622–1624. doi: 10.1109/LED.2012.2213794. [DOI] [Google Scholar]
- 117.Silva G.O., Mulato M. Urea-EnFET biosensor based on pHEGFET using FTO and ITO support films; Proceedings of the 223rd ECS Meeting; Toronto, ON, Canada. 12–16 May 2013. [Google Scholar]
- 118.Iskierko Z., Noworyta K., Sharma P.S. Molecular recognition by synthetic receptors: Application in field-effect transistor based chemosensing. Biosens. Bioelectron. 2018;109:50–62. doi: 10.1016/j.bios.2018.02.058. [DOI] [PubMed] [Google Scholar]
- 119.Lue C.-E., Yu T.-C., Yang C.-M., Pijanowska D.G., Lai C.-S. Optimization of urea—EnFET based on Ta2O5 layer with post annealing. Sensors. 2011;11:4526–4571. doi: 10.3390/s110504562. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 120.Abd-Alghafour N.M., Ahmed N.M., Hassan Z., Almessiere M.A., Bououdina M., Al-Hardan N.H. High sensitivity extended gate effect transistor based on V2O5 nanorods. J. Mater. Sci. 2017;28:1364–1369. doi: 10.1007/s10854-016-5669-9. [DOI] [Google Scholar]
- 121.Chirizzi D., Malitesta C. Potentiometric urea biosensor based on urease immobilized by an electrosynthesized poly(o-phenylenediamine) film with buffering capability. Sens. Actuators B Chem. 2011;157:211–215. doi: 10.1016/j.snb.2011.03.051. [DOI] [Google Scholar]
- 122.Temple-Boyer P., Benyahia A., Sant W., Pourciel-Gouzy M.L., Launay J.A. Martinez, Modelling of urea-EnFETs for haemodialysis applications. Sens. Actuators B Chem. 2008;131:525–532. doi: 10.1016/j.snb.2007.12.037. [DOI] [Google Scholar]
- 123.Sun L.-P., Zhang Z., Wang S., Zhang J., Li H., Ren L., Weng J., Zhang Q. Effect of pH on the interaction of gold nanoparticles with DNA and application in the detection of human p53 gene mutation. Nanoscale Res. Lett. 2009;4:216–220. doi: 10.1007/s11671-008-9228-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 124.Prakash O., Puliga S., Upadhyay L.S.B. Immobilization of watermelon (citrullus vulgaris) urease in agarose gel for urea estimation. Biotechnol. Bioprocess Eng. 2007;12:131–135. doi: 10.1007/BF03028638. [DOI] [Google Scholar]
- 125.Dhawan G., Sumana G., Malhotra B.D. Recent developments in urea biosensors. Biochem. Eng. J. 2009;44:42–52. doi: 10.1016/j.bej.2008.07.004. [DOI] [Google Scholar]
- 126.Sungur S., Murat Elcin Y., Akbulut U. Studies on immobilization of urease in gelatin by cross-linking. Biomaterials. 2003;13:795–800. doi: 10.1016/0142-9612(92)90020-O. [DOI] [PubMed] [Google Scholar]
- 127.Yin L.-T., Lin Y.-T., Leu Y.-C., Hu C.-Y. Enzyme immobilization on nitrocellulose film for pH-EGFET type biosensors. Sens. Actuators B Chem. 2010;148:207–213. doi: 10.1016/j.snb.2010.04.042. [DOI] [Google Scholar]
- 128.Ulber R., Scheper T. Enzyme Biosensors Based on ISFETs. In: Mulchandani A., Rogers K.R., editors. Enzyme and Microbial Biosensors. Volume 6 Humana Press; New York, NY, USA: 1998. Methods in Biotechnology. [Google Scholar]
- 129.Clark L.C., Jr., Lyons C. Electrode systems for continuous monitoring in cardiovascular surgery. Ann. N. Y. Acad. Sci. 1962;102:29–45. doi: 10.1111/j.1749-6632.1962.tb13623.x. [DOI] [PubMed] [Google Scholar]
- 130.Lei Y., Yan X., Zhao J., Liu X., Song Y., Luo N., Zhang Y. Improved glucose electrochemical biosensor by appropriate immobilization of nano-ZnO. Colloids Surf. B Biointerfaces. 2011;82:168–172. doi: 10.1016/j.colsurfb.2010.08.034. [DOI] [PubMed] [Google Scholar]
- 131.Yang K., She G.-W., Wang H., Ou X.-M., Zhang X.-H., Lee C.-S., Lee S.-T. ZnO Nanotube arrays as biosensors for glucose. J. Phys. Chem. C. 2009;113:20169–20172. doi: 10.1021/jp901894j. [DOI] [Google Scholar]
- 132.Zhao Y., Yan X., Kang Z., Lin P., Fang X., Lei Y., Ma S., Zhang Y. Highly sensitive uric acid biosensor based on individual zinc oxide micro/nanowires. Microchim. Acta. 2013;180:759–766. doi: 10.1007/s00604-013-0981-z. [DOI] [Google Scholar]
- 133.Umar A., Rahman M.M., Kim S.H., Hahn Y.B. ZnO nanonails: Synthesis and their application as glucose biosensor. J. Nanosci. Nanotechnol. 2008;8:3216–3221. doi: 10.1166/jnn.2008.116. [DOI] [PubMed] [Google Scholar]
- 134.Li X., Zhao C., Liu X. A paper-based microfluidic biosensor integrating zinc oxide nanowires for electrochemical glucose detection. Microsyst. Nanoeng. 2015;1:15014. doi: 10.1038/micronano.2015.14. [DOI] [Google Scholar]
- 135.Chiu Y.-S., Tseng C.-Y., Lee C.-T. An extended-gate CMOS sensor array with enzyme-immobilized microbeads for redox-potential glucose detection; Proceedings of the Biomedical Circuits and Systems Conference (BioCAS); Lausanne, Switzerland. 22–24 October 2014. [Google Scholar]
- 136.Vieira N.C.S., Figueiredo A., de Queiroz A.A.A., Zucolotto V., Guimarães F.E.G. Self-Assembled Films of Dendrimers and Metallophthalocyanines as FET-Based Glucose Biosensors. Sensors. 2011;11:9442–9449. doi: 10.3390/s111009442. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 137.Anan H., Kamahori M., Ishige Y., Nakazato K. Redox-potential sensor array based on extended-gate field-effect transistors with ω-ferrocenylalkanethiol-modified gold electrodes. Sens. Actuators B Chem. 2013;187:254–261. doi: 10.1016/j.snb.2012.11.016. [DOI] [Google Scholar]
- 138.Chou J.-C., Yang H.-Y., Chen C.-W. Glucose biosensor of ruthenium-doped TiO2 sensing electrode by co-sputtering system. Microelectron. Reliab. 2010;50:753–756. doi: 10.1016/j.microrel.2010.01.025. [DOI] [Google Scholar]
- 139.Lee C.-T., Chiu Y.-S., Ho S.-C., Lee Y.-J. Investigation of a photoelectrochemical passivated ZnO-based glucose biosensor. Sensors. 2011;11:4648–4655. doi: 10.3390/s110504648. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 140.Fathollahzadeh M., Hosseini M., Norouzi M., Ebrahimi A., Fathipour M., Kolahdouz M., Haghighi B. Immobilization of glucose oxidase on ZnO nanorods decorated electrolyte-gated field effect transistor for glucose detection. J. Solid State Electrochem. 2018;22:61–67. doi: 10.1007/s10008-017-3716-y. [DOI] [Google Scholar]
- 141.Riccardi D., Valenti G. Localization and function of the renal calcium-sensing receptor. Nat. Rev. Nephrol. 2016;12:414–425. doi: 10.1038/nrneph.2016.59. [DOI] [PubMed] [Google Scholar]
- 142.Pinton P., Giorgi C., Siviero R., Zecchini E., Rizzuto R. Calcium and apoptosis: ER-mitochondria Ca2+ transfer in the control of apoptosis. Oncogene. 2008;27:6407–6418. doi: 10.1038/onc.2008.308. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 143.Asif M.H., Danielsson B., Willander M. ZnO Nanostructure-Based Intracellular Sensor. Sensors. 2015;15:11787–11804. doi: 10.3390/s150511787. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 144.Ejeian F., Etedali P., Mansouri-Tehrani H.A., Soozanipour A., Low Z.X., Asadnia M., Taheri-Kafrani A., Razmjou A. Biosensors for wastewater monitoring: A review. Biosens. Bioelectron. 2018;118:66–79. doi: 10.1016/j.bios.2018.07.019. [DOI] [PubMed] [Google Scholar]
- 145.Lewenstam A. Routines and Challenges in Clinical Application of Electrochemical Ion-Sensors. Electroanalysis. 2014;26:1171–1181. doi: 10.1002/elan.201400061. [DOI] [Google Scholar]
- 146.Chou J.-C., Sung H.-F., Hsia W.-L., Huang Y.-P. Calcium Ion Sensors and Fabrication Method Thereof, and Sensing Systems Comprising the Same. US20090266712A1. U.S. Patent. 2009 Oct 29;
- 147.Chou J.-C., Chen C.-W., Jiang Y.-H. Method for Forming Extended Gate Field Effect Transistor (EGFET) Based Sensor and the Sensor Therefrom. US20090278175A1. U.S. Patent. 2012 Mar 13;
- 148.Chung W.-Y., Silverio A.A., Tsai V.F.S., Cheng C., Chang S.-Y., Ming-Ying Z., Kaoc C.-Y., Chend S.-Y., Pijanowska D. An implementation of an electronic tongue system based on a multi-sensor potentiometric readout circuit with embedded calibration and temperature compensation; Proceedings of the IEEE Sensors Conference; Busan, Korea. 1–4 November 2015. [Google Scholar]
- 149.Asif M.H., Nur O., Willander M., Yakovleva M., Danielsson B. Studies on calcium ion selectivity of ZnO nanowire sensors using ionophore membrane coatings. Res. Lett. Nanotechnol. 2008;2008:1–4. doi: 10.1155/2008/701813. [DOI] [Google Scholar]
- 150.Purwidyantri A., Kamajaya L., Chen C.-H., Luo J.-D., Chiou C.-C., Tian Y.-C., Lin C.-Y., Yang C.-M., Lai C.-S. A colloidal nanopatterning and downscaling of a highly periodic Au nanoporous EGFET biosensor. J. Electrochem. Soc. 2018;165:3170–3177. doi: 10.1149/2.0241804jes. [DOI] [Google Scholar]
- 151.Chen C.-P., Ganguly A., Lu C.-Y., Chen T.-Y., Kuo C.-C., Chen R.-S., Tu W.-H., Fischer W.B., Chen K.-H., Chen L.-C. Ultrasensitive in situ label–free DNA detection using a GaN nanowire-based extended-gate field-effect-transistor sensor. Anal. Chem. 2011;83:1938–1943. doi: 10.1021/ac102489y. [DOI] [PubMed] [Google Scholar]
- 152.Vieira N.C.S., Figueiredo A., dos Santos J.F., Aoki S.M., Guimarãesb F.E.G., Zucolotto V. Label-free electrical recognition of a dengue virus protein using the SEGFET simplified measurement system. Anal. Methods. 2014;6:8882–8885. doi: 10.1039/C4AY01803F. [DOI] [Google Scholar]
- 153.Songa E.A., Okonkwo J.O. Recent approaches to improving selectivity and sensitivity of enzyme-based biosensors for organophosphorus pesticides: A review. Talanta. 2016;155:289–304. doi: 10.1016/j.talanta.2016.04.046. [DOI] [PubMed] [Google Scholar]
- 154.Dabrowski M., Sharma P.S., Iskierko Z., Noworyta K., Cieplak M., Lisowski W., Oborska S., Kuhn A., Kutner W. Early diagnosis of fungal infections using piezomicrogravimetric and electric chemosensors based on polymers molecularly imprinted with d-arabitol. Biosens. Bioelectron. 2016;79:627–635. doi: 10.1016/j.bios.2015.12.088. [DOI] [PubMed] [Google Scholar]
- 155.Sakata T., Matsumoto S., Nakajima Y., Miyahara Y. Potential behavior of biochemically modified gold electrode for extended–gate field–effect transistor. Jpn. J. Appl. Phys. 2005;44 doi: 10.1143/JJAP.44.2860. [DOI] [Google Scholar]
- 156.Kim D., Park J., Shin J., Kim P.K., Lim G., Shoji S. An extended gate FET-based biosensor integrated with a Si microfluidic channel for detection of protein complexes. Sens. Actuators B Chem. 2006;117:488–494. doi: 10.1016/j.snb.2006.01.018. [DOI] [Google Scholar]
- 157.Cho W., Lim C. Sensing properties of separative paper-based extended-gate ion-sensitive field-effect transistor for cost effective pH sensor applications. Solid-State Electron. 2017;140:96–99. doi: 10.1016/j.sse.2017.10.025. [DOI] [Google Scholar]
- 158.Park J., Cho W. Development of high-performance fully depleted silicon-on-insulator based extended-gate field-effect transistor using the parasitic bipolar junction transistor effect. Appl. Phys. Lett. 2012;101:133703. doi: 10.1063/1.4757000. [DOI] [Google Scholar]
- 159.Chin Y., Chou J., Lei Z., Sun T., Chung W., Hsiung S. Titanium nitride membrane application to extended gate field effect transistor pH sensor using VLSI technology. Jpn. J. Appl. Phys. 2001;40:6311. doi: 10.1143/JJAP.40.6311. [DOI] [Google Scholar]
- 160.Sanches Nascimento R.A., Mulato M. Mechanisms of Ion Detection for FET-Sensors Using FTO: Role of Cleaning Process, pH Sequence and Electrical Resistivity. Mater. Res. 2017;20:1369–1379. doi: 10.1590/1980-5373-mr-2017-0502. [DOI] [Google Scholar]
- 161.Batista P.D., Mulato M. Polycrystalline fluorine-doped tin oxide as sensoring thin film in EGFET pH sensor. J. Mater. Sci. 2010;45:5478–5481. doi: 10.1007/s10853-010-4603-4. [DOI] [Google Scholar]
- 162.Guidelli E.J., Guerra E.M., Mulato M. V2O5/WO3 mixed oxide films as pH-EGFET sensor: Sequential re-usage and fabrication volume analysis. ECS J. Solid State Sci. Technol. 2012;1:N39–N44. doi: 10.1149/2.007203jss. [DOI] [Google Scholar]
- 163.Tsai W., Huang B., Yang P., Wang K., Hsiao C., Cheng H. Oxygen plasma functionalized multiwalled carbon nanotube thin film as a pH sensing membrane of extended-gate field-effect transistor. IEEE Electron Device Lett. 2013;34:1307–1309. doi: 10.1109/LED.2013.2278214. [DOI] [Google Scholar]
- 164.Fernandes E.G.R., Vieira N.C.S., de Queiroz A.A.A., Guimarães F.E.G., Zucolotto V. Immobilization of poly(propylene imine) dendrimer/nickel phtalocyanine as nanostructured multilayer Films to be used as gate membranes for SEGFET pH sensors. J. Phys. Chem. C. 2010;114:6478–6483. doi: 10.1021/jp9106052. [DOI] [Google Scholar]
- 165.Purwidyantri A., Lai H.-C., Tsai S.-H., Luo J.-D., Chioud C.-C., Tiane Y.-C., Cheng C.-H., Linf Y.-T., Laif C.-S. Sensing performance of fibronectin-functionalized Au-EGFET on the detection of S. epidermidis biofilm and 16S rRNA of infection-related bacteria in peritoneal dialysis. Sens. Actuators B Chem. 2015;217:92–99. doi: 10.1016/j.snb.2014.11.017. [DOI] [Google Scholar]
- 166.Lin F., Chang H.Y., Hsiao S.H., Chen H.I., Liu W.C. Preparation and characterization of nickel oxide-based EGFET pH sensors; Proceedings of the 9th International Conference on Sensing Technology (ICST); Auckland, New Zealand. 8–10 December 2015. [Google Scholar]
- 167.Ahmed N.M., Kabaa E.A., Jaafar M.S., Omar A.F. Characteristics of extended-gate field-effect transistor (EGFET) based on porous n-type (111) silicon for use in pH sensors. J. Electron. Mater. 2017;460:5804–5813. doi: 10.1007/s11664-017-5604-8. [DOI] [Google Scholar]
- 168.Zulkefle M.A., Rahman R.A., Mahmood M.R., Abdullah W.F.H., Herman S.H. Sensing capability of TiO2 thin films with different thicknesses as sensing membrane of EGFET pH sensor; Proceedings of the International Symposium on Technology Management and Emerging Technologies (ISTMET); Langkawai Island, Malaysia. 25–27 August 2015. [Google Scholar]
- 169.Rosli A.B., Shariffudin S.S., Awang Z., Herman S.H. Deposition temperature dependence of ZnO nanostructures growth using TCVD for EGFET pH sensor; Proceedings of the IEEE Regional Symposium on Micro and Nanoelectronics (RSM); Batu Ferringhi, Malaysia. 23–25 August 2017. [Google Scholar]
- 170.Sabah F.A., Ahmed N.M., Hassan Z., Almessiere M.A. A novel CuS thin film deposition method by laser-assisted spray photolysis deposition and its application to EGFET. Sens. Actuators B Chem. 2017;247:197–215. doi: 10.1016/j.snb.2017.03.020. [DOI] [Google Scholar]
- 171.Rasheed H.S., Ahmed N.M., Matjafri M.Z. Ag metal mid layer based on new sensing multilayers structure extended gate field effect transistor (EG-FET) for pH sensor. Mater. Sci. Semicond. Process. 2018;74:51–56. doi: 10.1016/j.mssp.2017.10.011. [DOI] [Google Scholar]
- 172.Arafa H., Obahiagbon U., Kullman D., Dominguez F.-J., Magee A., Christen J.B. Characterization and application of a discrete quartz extended-gate ISFET for the assessment of tumor cell viability, International Conference on Electrical; Proceedings of the Electronics and System Engineering (ICEESE); Kuala Lumpur, Malaysia. 9–10 December 2014. [Google Scholar]
- 173.Shalmany S.H., Merz M., Fekri A., Chang Z.-Y., Hoofman R.J.O.M., Pertijs M.A.P. A 7 μW offset- and temperature-compensated pH-to-digital converter. J. Sens. 2017;2017 doi: 10.1155/2017/6158689. [DOI] [Google Scholar]
- 174.Lin M.-Y., Hsu W.-Y., Yang Y.-S., Huang J.-W., Chung Y.-L., Chen H. Immobilized rolling circle amplification on extended-gate field-effect transistors with integrated readout circuits for early detection of platelet-derived growth factor. Anal. Bioanal. Chem. 2016;408:4785–4797. doi: 10.1007/s00216-016-9568-y. [DOI] [PubMed] [Google Scholar]
- 175.Choi J., Lee H.H., Ahn J., Seo S., Shin J. Differential-mode biosensor using dual extended-gate metal-oxide-semiconductor field-effect transistors. Jpn. J. Appl. Phys. 2012;51:06FG05. doi: 10.7567/JJAP.51.06FG05. [DOI] [Google Scholar]
- 176.Kajisa T., Sakata T. Monitoring of hydroxyapatite crystal formation using field-effect transistor. Jpn. J. Appl. Phys. 2016;55:04EM09. doi: 10.7567/JJAP.55.04EM09. [DOI] [Google Scholar]
- 177.Hasko G., Sitkovsky M.V., Szabo C. Immunomodulatory and neuroprotective effects of inosine. Trends Pharmacol. Sci. 2004;25:152–157. doi: 10.1016/j.tips.2004.01.006. [DOI] [PubMed] [Google Scholar]
- 178.Iskierko Z., Sosnowska M., Sharma P.S., Benincori T., D’Souza F., Kaminska I., Fronc K., Noworyta K. Extended-gate field-effect transistor (EG-FET) with molecularly imprinted polymer (MIP) film for selective inosine determination. Biosens. Bioelectron. 2015;74:526–533. doi: 10.1016/j.bios.2015.06.073. [DOI] [PubMed] [Google Scholar]