Abstract
Intramedullary nailing is the most popular and widely used method for treating tibial shaft fractures. Intramedullary nailing involves minimal surgical dissection, allowing preservation of blood supply by not disrupting the soft tissue around the fracture. The procedure is performed with the following steps: (1) the patient is positioned supine on the radiolucent operating table with a bump under the ipsilateral hip; (2) a 4 to 6-cm longitudinal incision is made 2 to 4 cm directly proximal to the superior pole of the patella; (3) the quadriceps tendon is sharply incised at its midline and split longitudinally; (4) a cannula device with a blunt trocar and protective sleeve is inserted into the knee joint between the articular surface of the patella and the trochlea of the distal part of the femur, after which a second pin can be inserted through the cannula device and into the distal part of the femur to stabilize the cannula and keep it from backing out; (5) a 3.2-mm guide pin is inserted and placed resting at the junction of the articular surface and the anterior cortex of the tibia at the appropriate starting point in line with the intramedullary canal; (6) the guide pin is advanced 8 to 10 cm into the proximal part of the tibia, the inner centering sleeve is removed, and the cannulated entry drill is passed over the pin through the outer protective sleeve and used to ream down to the metadiaphyseal level of the proximal part of the tibia; (7) the fracture is reduced; (8) a ball-tipped guidewire is centrally passed across the fracture down to the level of the distal tibial physeal scar; (9) incremental reaming is performed, and the appropriate-size tibial nail is inserted down the tibial canal; (10) the appropriate nail position is confirmed radiographically, and distal interlocking screws are placed with a freehand technique, after which the proximal aiming arm is attached to the insertion handle and interlocking screws are drilled, measured, and placed into the proximal part of the tibia as well; and (11) all incisions as well as the quadriceps tendon are closed. Intramedullary nail fixation is a safe and effective method for treating tibial shaft fractures, and with appropriate surgical technique good outcomes and reproducible results can be expected. This soft-tissue-sparing method of fracture fixation achieves biomechanical stabilization of the fracture using a load-sharing device that allows for earlier postoperative ambulation.
Footnotes
Published outcomes of this procedure can be found at: J Orthop Traumatol. 2017 Mar;18(1):69-76, J Orthop Trauma. 1999 Nov;13(8):550-3, and J Orthop Trauma. 2014;28(5):263-9.
Disclosure: The authors indicated that no external funding was received for any aspect of this work. The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJSEST/A223).
References
- 1.Hooper GJ, Keddell RG, Penny ID. Conservative management or closed nailing for tibial shaft fractures. A randomised prospective trial. J Bone Joint Surg Br. 1991. January;73(1):83-5. [DOI] [PubMed] [Google Scholar]
- 2.Duan X, Al-Qwbani M, Zeng Y, Zhang W, Xiang Z. Intramedullary nailing for tibial shaft fractures in adults. Cochrane Database Syst Rev. 2012. January 18;1:CD008241. [DOI] [PubMed] [Google Scholar]
- 3.Shao Y, Zou H, Chen S, Shan J. Meta-analysis of reamed versus unreamed intramedullary nailing for open tibial fractures. J Orthop Surg Res. 2014. August 23;9:74. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Xia L, Zhou J, Zhang Y, Mei G, Jin D. A meta-analysis of reamed versus unreamed intramedullary nailing for the treatment of closed tibial fractures. Orthopedics. 2014. April;37(4):e332-8. [DOI] [PubMed] [Google Scholar]
- 5.Xue D, Zheng Q, Li H, Qian S, Zhang B, Pan Z. Reamed and unreamed intramedullary nailing for the treatment of open and closed tibial fractures: a subgroup analysis of randomised trials. Int Orthop. 2010. December;34(8):1307-13. Epub 2009 Oct 20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Toivanen JA, Väistö O, Kannus P, Latvala K, Honkonen SE, Järvinen MJ. Anterior knee pain after intramedullary nailing of fractures of the tibial shaft. A prospective, randomized study comparing two different nail-insertion techniques. J Bone Joint Surg Am. 2002. April;84(4):580-5. [DOI] [PubMed] [Google Scholar]
- 7.Devitt AT, Coughlan KA, Ward T, McCormack D, Mulcahy D, Felle P, McElwain JP. Patellofemoral contact forces and pressures during intramedullary tibial nailing. Int Orthop. 1998;22(2):92-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Hernigou P, Cohen D. Proximal entry for intramedullary nailing of the tibia. The risk of unrecognised articular damage. J Bone Joint Surg Br. 2000. January;82(1):33-41. [DOI] [PubMed] [Google Scholar]
- 9.Mochida H, Kikuchi S. Injury to infrapatellar branch of saphenous nerve in arthroscopic knee surgery. Clin Orthop Relat Res. 1995. November;320:88-94. [PubMed] [Google Scholar]
- 10.Nyland J, Bealle DP, Kaufer H, Johnson DL. Long-term quadriceps femoris functional deficits following intramedullary nailing of isolated tibial fractures. Int Orthop. 2001;24(6):342-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Väistö O, Toivanen J, Kannus P, Järvinen M. Anterior knee pain after intramedullary nailing of fractures of the tibial shaft: an eight-year follow-up of a prospective, randomized study comparing two different nail-insertion techniques. J Trauma. 2008. June;64(6):1511-6. [DOI] [PubMed] [Google Scholar]
- 12.Väistö O, Toivanen J, Paakkala T, Järvelä T, Kannus P, Järvinen M. Anterior knee pain after intramedullary nailing of a tibial shaft fracture: an ultrasound study of the patellar tendons of 36 patients. J Orthop Trauma. 2005. May-Jun;19(5):311-6. [PubMed] [Google Scholar]
- 13.Keating JF, Orfaly R, O’Brien PJ. Knee pain after tibial nailing. J Orthop Trauma. 1997. January;11(1):10-3. [DOI] [PubMed] [Google Scholar]
- 14.Jones M, Parry M, Whitehouse M, Mitchell S. Radiologic outcome and patient-reported function after intramedullary nailing: a comparison of the retropatellar and infrapatellar approach. J Orthop Trauma. 2014. May;28(5):256-62. [DOI] [PubMed] [Google Scholar]
- 15.Sanders RW, DiPasquale TG, Jordan CJ, Arrington JA, Sagi HC. Semiextended intramedullary nailing of the tibia using a suprapatellar approach: radiographic results and clinical outcomes at a minimum of 12 months follow-up. J Orthop Trauma. 2014. May;28(5):245-55. [DOI] [PubMed] [Google Scholar]
- 16.Saldua NS, Kuhn KM, Mazurek MT. Thermal necrosis complicating reamed intramedullary nailing of a closed tibial diaphysis fracture: a case report. J Orthop Trauma. 2008. Nov-Dec;22(10):737-41. [DOI] [PubMed] [Google Scholar]
- 17.Cannada LK, Anglen JO, Archdeacon MT, Herscovici D, Jr, Ostrum RF. Avoiding complications in the care of fractures of the tibia. J Bone Joint Surg Am. 2008. August;90(8):1760-8. [PubMed] [Google Scholar]
- 18.Shuler FD, Obremskey WT. Tibial shaft fractures. In: Stannard JP, Schmidt AH, Kregor PJ, editors. Surgical treatment of orthopaedic trauma. New York: Thieme; 2007. p 742-66. [Google Scholar]
- 19.Bhandari M, Guyatt GH, Tong D, Adili A, Shaughnessy SG. Reamed versus nonreamed intramedullary nailing of lower extremity long bone fractures: a systematic overview and meta-analysis. J Orthop Trauma. 2000. January;14(1):2-9. [DOI] [PubMed] [Google Scholar]
- 20.Zelle BA, Gruen GS, Klatt B, Haemmerle MJ, Rosenblum WJ, Prayson MJ. Exchange reamed nailing for aseptic nonunion of the tibia. J Trauma. 2004. November;57(5):1053-9. [DOI] [PubMed] [Google Scholar]