Abstract
Finite elasticity theory has been commonly used to model skeletal muscle. A very large range of heterogeneous constitutive laws has been proposed. In this review, the most widely used continuum models of skeletal muscles were synthetized and discussed. Trends and limitations of these laws were highlighted to propose new recommendations for future researches. A systematic review process was performed using two reliable search engines as PubMed and ScienceDirect. 40 representative studies (13 passive muscle materials and 27 active muscle materials) were included into this review. Note that exclusion criteria include tendon models, analytical models, 1D geometrical models, supplement papers, and indexed conference papers. Trends of current skeletal muscle modeling relate to 3D accurate muscle representation, parameter identification in passive muscle modeling, and the integration of coupled biophysical phenomena. Parameter identification for active materials, assumed fiber distribution, data assumption, and model validation are current drawbacks. New recommendations deal with the incorporation of multimodal data derived from medical imaging, the integration of more biophysical phenomena, and model reproducibility. Accounting for data uncertainty in skeletal muscle modeling will be also a challenging issue. This review provides, for the first time, a holistic view of current continuum models of skeletal muscles to identify potential gaps of current models according to the physiology of skeletal muscle. This opens new avenues for improving skeletal muscle modeling in the framework of in silico medicine.
1. Introduction
Human skeletal muscle is the motor of the locomotion function of the human body. This specific living tissue has complex multiscale and hierarchical architecture (i.e., from fibers to myofibrils, sarcomeres, and contractile proteins (actin and myosin)) and function (e.g., voluntary contraction control) [1–4]. Hierarchical bundles of assembled fibers and fibrils, which are formed by tropocollagen molecules with a helix structure, are basic building constituents of skeletal muscles. The organization of hierarchical fibers and their activation mechanism allow the whole muscle contraction to occur. Moreover, a passive matrix of connective tissues contributes into the force generation process in a cooperative manner within fibers. Skeletal muscle activation mechanism starts by a progressive activation in time and in space of multiple motor units (MU) due to a neural command generated through motor neuron axons from the nervous system. Recruited MU's number, size, morphology, and their behaviors (e.g., firing rate or patterns) determine the activation level and produced mechanical force [5]. Note also that the action potential transmission allows the voltage-sensitive protein (i.e., sarco(endo) plasmic reticulum ATPases SERCA2a in the sarcoplasmic reticulum) to change its shape to open calcium release channel. Then, calcium ions bind to troponin to change its shape allowing tropomyosin to move to the actin side to enable the contraction process at the sarcomere level. Myosin reaches forward, binds to actin, contracts, and releases actin. Then, this protein reaches forward again to bind actin in a new cycle. This interactive and cycling process allows muscle mechanical force to be produced [1, 6, 7]. Skeletal muscle exhibits commonly a nonlinear behavior during dynamic movements. Critical experiments have been done to characterize the skeletal muscle in in vitro as well as in in vivo conditions [8–11]. However, due to the complex nature of the skeletal muscle, some physical quantities cannot be measured in a noninvasive manner. For example, force distribution and intrinsic tissue stress inside the skeletal muscle under isotropic and anisotropic contractions are among the current immeasurable quantities in in vivo conditions. Mathematical modeling of the skeletal muscle is the current engineering solution to estimate these quantities [12–14].
One of the landmark mathematical models of the skeletal muscle activation, contraction, and force has been proposed from the well-known experiment performed by Hill in 1938 to elucidate the muscle work and contraction velocity phenomena. Based on this original finding, 1D lumped-parameter model of muscle contraction and force has been developed [15] and this model has been widely used in rigid body musculoskeletal modeling [14]. Despite its compact formulation with only 5 parameters and computational advantage, this 1D lumped-parameter model could not describe complex structural and functional relationships of the skeletal muscle in an accurate manner, especially in the case of muscle diseases (e.g., dystrophy or spasticity) [16–20]. To investigate the skeletal muscle in its complex nature, continuum mechanics approach has been used. The skeletal muscle has usually been modeled as an inhomogeneous and nearly incompressible body. A range of constitutive laws from the simple elastic material to the complex multiscale chemo-electro-mechanical material has been proposed [21–23]. However, these continuum models are very heterogeneous and it is difficult to elucidate the common modeling aspects and to identify potential gaps according to the real physiology of the skeletal muscle. There is a lack of systematic review of these continuum models. This information may allow the right choice of a model for a specific case study. Moreover, model parameters cover a very large range of values. Thus, the determination of currently used ranges of values if available is necessary for the modeling and simulation of the skeletal muscle in the future.
The objective of the present review study was to synthetize and discuss the widely used continuum models of skeletal muscles in the literature. Useful information related to the developed model formulation and parameters were also reported. Moreover, trends and limitations of these models were highlighted to propose new challenging recommendations for future researches.
2. Continuum Models of Skeletal Muscles
2.1. Review Method
A systematic review process was applied for this present study using two reliable search engines for biomedical literature as PubMed and ScienceDirect. The most widely used continuum models of skeletal muscles were identified and retrieved. Specific keywords (finite element muscle modeling, hyperelastic muscle model, transversely isotropic muscle model, fiber-reinforced muscle model, and muscle stress analysis) were used. The flowchart of the applied review process is shown in Figure 1. First, meta-data (e.g., title, source) of each paper were initially screened to identify the retrieved papers. All irrelevant papers (e.g., anatomy, experimentation, other muscle tissues (cardiac, vascular smooth, and uterus)) were excluded. The number of screened papers is 142 from 492 retrieved papers. Then, an experienced biomechanical expert of the musculoskeletal system modeling scanned all retrieved results using abstract information to select the most relevant studies. Finally, 40 representative studies (13 passive muscle materials and 27 active muscle materials) were included in this review. Note that exclusion criteria include tendon models, analytical models, 1D geometrical models, supplement papers, and indexed conference papers. Thus, the eligibility criterion focuses on muscle model development and implementation with 3D geometries. Constitutive models with complex muscle network were also included in the review. Note that the search period was set up from 1998 to 2017.
A common structure (i.e., related reference with first author name and the year of publication, muscles, geometries, constitutive laws, simulations, and validation) was used to summarize all retrieved papers. This common structure allows integrating and aggregating the information about the analyzed continuum models: what are the research group and year of work, what are the muscles modeled, how to obtain the geometries, what are the constitutive laws to be used or implemented, and what are the performed simulations and the validation process (if exists) of the developed skeletal muscle models. All analyzed papers were classified into two categories: skeletal muscle as a passive material and skeletal muscle as an active material. A summary of all used and developed continuum models of skeletal muscles was provided to establish common aspects as well as to identify the gaps according to the real physiology of skeletal muscles. Then, respective trends and weaknesses of these models were analyzed and presented. Finally, new challenging recommendations were provided for future researches.
2.2. Skeletal Muscle as a Passive Material
Mathematical formulation of skeletal muscle physiology is a complex engineering task. In particular, the consideration of all physiological aspects is practically difficult. One of the most difficult tasks relates to the integration of active behavior of skeletal muscles. However, this leads to complex model formulation and important computational cost. Hence, the modeling of only passive behavior (i.e., consideration of passive matrix of connective tissues and assumption of sarcomere length change in a passive manner) of the skeletal muscle is an acceptable solution under some specific conditions (e.g., virtual surgery simulation where skeletal muscles exhibit commonly a passive behavior or to simulate in vitro testing of muscle passive behavior). Classical material laws have been used for modeling the passive behavior of skeletal muscles (Tables 1 and 2). The simplest constitutive behavior is the linear elastic law, which is used to model facial muscles in the nonactive state (e.g., orbicularis oris, zygomaticus major and minor, buccinator and risorius, or depressor anguli oris) and simulate the maxillofacial surgery [22]. This model assumes that the skeletal muscle exhibits as an elastic solid under external mechanical stimuli. It is likely to point out that only fiber fascicles in the passive state and related matrix of connective tissues have been considered in this model formulation. However, it is important to note that this model is anisotropic including also the strain-energy formulation to describe the active state of the skeletal muscles (please refer to Section 2.3 to see the description of this active component). Facial muscles have been modeled in a more complex manner using a fiber-based and orthogonal direction-based elastic material [24] or a nonlinear elastic-viscoplastic model [21] or an orthogonal elastic material [25] or a hyperelastic material using the Mooney-Rivlin formulation [26]. Moreover, skeletal muscles in the upper limbs (subscapularis, supra, and infraspinatus), spine, and lower limbs (ischios, quadriceps, gracilis, sartorius, gastrocnemius, and biceps femoris) have been commonly modeled using a hyperelastic material [27] (based on the Neo-Hookean formulation [28–30] or based on the Mooney-Rivlin formulation [26, 31, 32]) or a nonlinear viscoelastic material [33] or a visco-poroelastic material [34]. In fact, the use of hyperelastic models assumes that the skeletal muscle exhibits a large deformation (>5%) behavior under external solicitation while visco-poroelastic law allows the fluid-filled fiber fascicles and connective tissue to be taken into consideration in model formulation. Finally, orthogonal elastic material allows the fiber orientation to be defined in two different directions with two different constitutive parameters. Only two parameters are needed for the simplest linear elastic law or hyperelastic law based on Neo-Hookean formulation. The use of hyperelastic law based on the Mooney-Rivlin formulation requires three parameters. Note that the number of model parameters increases when more biophysical phenomena are included into constitutive laws. For example, three main parameters are required to formulate the visco-poroelastic material [34]. Six parameters are needed to define the nonlinear elastic-viscoplastic model [21]. Common outcomes of passive muscle materials are muscle stress and strain.
Table 1.
References | Muscles | Geometries | Constitutive laws | Simulation | Validation |
---|---|---|---|---|---|
Beldie et al. [22] | 20 facial muscles | 1 patient, 3D geometries from MRI data | Linear elastic material (E = 6.2 kPa, v = 0.49) | Maxillofacial surgery | In vivo postsurgery data (skin envelop) |
Chabanas et al. [24] | 6 facial muscles | 6 patients, muscles modeled as embedded group elements | Fiber-based and orthogonal direction-based elastic material (E = 6.2 kPa and E-fiber = 110 kPa) |
Bone repositioning | No |
Büchler et al. [27] | Subscapularis, supra, and infraspinatus | Two human fresh frozen cadavers, 3D geometries from CT images | Hyperelastic, and incompressible material α = 0.12 MPa, β = 1.0 |
Internal and external rotations of the shoulders | No |
Hedenstierna and Halldin [33] | Neck muscles | 1 healthy subject, 3D geometries from MRI data | Ogden hyperelastic, viscoelastic material (LS-DYNA FE code) μi = 13337&αi = 14.5 |
Impact simulations | Resulting head and vertebral kinematics |
Barbarino et al. [21] | 20 facial muscles | 1 healthy subject, 3D geometries from MRI data | Nonlinear elastic-viscoplastic model (6 parameters) (UMAT Abaqus) | Aging | In vivo MRI-based displacement |
Avril et al. [28] | Calf muscles | 1 healthy subject, 2D geometries from MRI data | Hyperelastic material (Neo-Hookean model) C10 = [9.4–12.9] kPa K = [61–78] kPa |
Compression garments | In vivo MRI measurement (deformed geometries) |
Kim et al. [25] | Facial muscles | 4 patients, 3D geometries from atlas | Orthogonal elastic material (E_acrossFiber = 0.79 MPa, E_alongFiber = 0.5 Mpa, v = 0.43) |
Cranio-maxillofacial (CMF) surgery | Postoperative CT scan data (distance map) |
Table 2.
References | Muscles | Geometries | Constitutive laws | Simulation | Validation |
---|---|---|---|---|---|
Wang et al. [31] | Calf muscles | 1 healthy subject, 2D geometries from MRI data | Hyperelastic material (Mooney-Rivlin model) C10 = 1310 Pa, C01 = −961 Pa, C11 = 886 Pa | Outside compression | In vivo MRI measurement (deformed geometries, cross-sectional area reduction) |
Wu et al. [26] | 20 facial muscles | 1 healthy subject, 3D geometries from MRI data | Hyperelastic material (Mooney-Rivlin model) C10 = 2.5 kPa, C01 = 1.175 kPa | Facial expressions | Skin deformation from the structured-light scanner |
Affagard et al. [29] | Ischios, quadriceps, gracilis, and sartorius | 1 healthy subject, 2D geometries from MRI data | Hyperelastic material (Neo-Hookean model) C10 = [1.75–3.75] kPa, D = 18 MPa−1 | Contention, compression, and indentation | Ultrasound displacement measurement |
Zöllner et al. [30] | Gastrocnemius | 1 healthy subject, 3D geometries from MRI data | Hyperelastic material (Neo-Hookean model) λ = 0.714 N/mm2 and μ (G) = 0.179 N/mm2 | High heel posture | Qualitative comparison with literature |
Lee et al. [32] | Generic (back spine muscles) | 3 healthy subjects, 3D geometries from scanning | Hyperelastic material (Mooney-Rivlin model) C10 = 1.65 kPa, C01 = 3.35 kPa | Contact pressure simulation | Contact pressure measurements |
Wheatley et al. [34] | Biceps femoris | Ideal 3D cuboid form geometries | Visco-poroelastic material (FEBio) k0 = [4.250](m4/N − s); M = [0.16 10]; α = [0.12] | Compression | In vitro permeability measurement |
The respective constitutive equations of commonly used hyperelastic material based on the Neo-Hookean and Mooney-Rivlin formulations are expressed as follows:
(1) |
(2) |
where U is the strain energy density function; I1&I2 are the first and second invariants of the right Cauchy-Green deformation tensor; C10&C01&D are material constants and their respective used values cover a large range (Table 1); J = det(F) is the gradient deformation tensor.
Medical imaging techniques (e.g., computed tomography (CT) and magnetic resonance imaging (MRI)) are common data acquisition modalities used to develop 2D and 3D geometrical models of skeletal muscles in in vitro and in vivo conditions [21, 22, 24–32], except for one study using 3D ideal geometry [34]. There is no clear definition of fiber distribution in passive muscle modeling. The modeling of the skeletal muscle as a passive material has been done in a large range of simulations such as impact simulation [33], maxillofacial surgery [22, 24, 25], facial expressions [26], uniaxial and multiple-axial loadings [28, 29, 31, 32, 34], dynamic movements [27], and aging process [21]. Parameter identification using inverse approach and experimental data was performed using 2D continuum models [28, 29]. Model validation has been commonly performed using experimental data [21, 22, 25, 26, 28, 29, 31, 32, 34] (e.g., postsurgery data for skin envelop [22] or skin deformation from the structured-light scanner [26]). Literature data was also used for comparing with model outcomes [30]. Note that model validation was not performed in two studies [24, 27].
It is noted that the use of passive material may be an acceptable solution for the simulation of virtual surgery procedures in which simulation time is an important factor. Thus, real-time feedback related to skeletal muscle strain and stress during surgical operation may be achieved to provide quantitative indicators for making surgical decisions. Furthermore, when in vitro mechanical testing is designed and performed, passive muscle material may be used for model calibration and parameter identification. Generally speaking, most of the passive constitutive laws are appropriate for the designed purposes and available data. However, two studies suffered from the lack of validation making it impossible to evaluate the modeling accuracy and outcome precision [24, 27].
2.3. Skeletal Muscle as an Active Material
The modeling of the skeletal muscle as an active material requires the integration of hierarchical fibers and their activation mechanism. Different constitutive laws have been proposed and developed for modeling active skeletal muscles (Tables 3–6). Transversely isotropic behavior has been commonly described in most of developed constitutive models. A specific case of orthotropic behavior has been also proposed [41, 42]. Most of the developed laws have been inspired from the Hill-type phenomenological model including passive and active components of the skeletal muscle. It is important to emphasize that the hyperelastic behavior has been included in most of developed models to describe the skeletal muscle passive component [48, 52]. The active component is commonly defined by the relationship between the fiber activation, stretch, and force components. Note that these force components include commonly the passive and active fiber forces.
Table 3.
References | Muscles | Geometries | Fiber architecture | Constitutive laws | Simulation | Validation |
---|---|---|---|---|---|---|
Martins et al. [35] | Brachialis | 3D geometry from imaging data of the Visible Human Project | Fibers aligned in one direction | Active transversely isotropic, hyperelastic, and quasi-incompressible material (5 parameters, Abaqus UMAT routine) | Elongation | No |
Johansson et al. [36] | Generic | Ideal geometries | Circularly directed and transversely orientated fibers | Active fiber-driven hyperelastic material | Isometric activation, isokinetic shortening, and stop quick release | Comparison with literature |
Yucesoy et al. [37] | Generic | Ideal 3D geometries | Parallel fiber distribution | Active linked fiber-matrix mesh material | Activation, shear | Comparison with literature (muscle length-force characteristics) |
Fernandez et al. [38] | Rectus femoris | 1 patient, 3D geometries from MRI data | Bipennate fiber orientation | Active orthotropic material | Flexion | No |
Blemker et al. [39] | Biceps brachii | Ideal geometries | Parallel fascicles with equal and unequal lengths, curved fascicles | Active fiber-reinforced composite with transversely isotropic material | Shortening | Measured length |
d'Aulignac et al. [40] | Levator ani muscle | 72-year-old female cadaver, 3D geometries from MRI data | Fibers aligned in one direction | Active transversely isotropic, hyperelastic, and quasi-incompressible material (5 parameters, Abaqus UMAT routine) | Deformation under pressure and muscle contraction | No |
Tang et al. [41, 42] | Gastrocnemius | 1 frog, 3D geometries from elliptical cross sections | Parallel fiber distribution | Active orthotropic material | Deformation in several planes | Measured deformation shape |
Table 4.
References | Muscles | Geometries | Fiber architecture | Constitutive laws | Simulation | Validation |
---|---|---|---|---|---|---|
Chi et al. [43] | Generic | Simplified muscle-tendon geometries | Parallel fibers at a pennation angle | Active transversely isotropic hyperelastic material | Shortening | Comparison with literature data |
Lu et al. [44] | Tibialis anterior | 1 New Zealand white rabbit, ideal 3D geometries | Parallel fiber distribution | Active, quasi-incompressible, transversely isotropic, and visco-hyperelastic composite material (14 parameters) | Elongation | Measured stress and strain |
Rehorn and Blemker [45] | Biceps femoris longhead | 1 heathy subject, 3D geometries from MRI data | Mapping technique | Active fiber-reinforced composite with transversely isotropic material | Lengthening contractions | No |
Sharafi and Blemker [46] | Rectus femoris and soleus | 1 rabbit, 3D geometries from histological cross sections | Parallel fiber distribution in a single direction | Active hyperelastic, nearly incompressible, transversely isotropic material | Macroscopic shear | No |
Ehret et al. [47] | Tibialis anterior | Ideal geometries | Loading-driven fiber direction | Active transversely isotropic material | Shortening and lengthening | Experimental stress response |
Böl et al. [23] | Biceps brachii | 1 healthy subject, 3D geometries from MRI data | Fusiform fiber orientation at a pennation angle | Active electromechanical material based on the transversely isotropic law (13 parameters) | Contraction | No |
Paetsch et al. [48] | Ventral interior lateral | 1 tobacco hornworm caterpillar Manduca sexta, ideal geometries | Parallel distribution to the longitudinal direction | Active transversely isotropic nonlinear hyperelastic material (20 parameters) | Uniaxial extension | No |
Table 5.
References | Muscles | Geometries | Fiber architecture | Constitutive laws | Simulation | Validation |
---|---|---|---|---|---|---|
Röhrle et al. [49] | Tibialis anterior | Ideal 3D geometries | Parallel fiber distribution at a pennation angle | Active multiscale electromechanical material | Activation | Qualitative comparison with literature |
Hernández-Gascón et al. [50] | Tibial anterior | 1 rat, 3D geometries from MRI | Fusiform form | Active electromechanical material (thermodynamically consistent constitutive model) (11 parameters) | Isometric and concentric contractions | Comparison with literature |
Heidlauf and Röhrle [51] | Tibialis anterior | Ideal 3D fiber geometries | Parallel fiber distribution along the edge of the cuboid | Active multiscale chemo-electro-mechanical material (20 parameters) | Shortening, isometric contraction | Comparison with literature (muscle length-force characteristics) |
Toumanidou and Noailly [52] | Lumbar spine muscles | 3D muscle network from anatomical landmarks | Fibers aligned in one direction | Active transversely isotropic, hyperelastic, and quasi-incompressible material (8 parameters, UMAT Abaqus) | Standing posture and lying position | Comparison with literature (intradiscal pressure) |
Kinugasa et al. [53] | Gastrocnemius and soleus | 1 healthy subject, 3D geometries from MRI data | Fascicle orientation measurement from ultrasound images | Active transversely isotropic, hyperelastic, and quasi-incompressible material | Plantar flexion | Achilles tendon force measurements |
Spyrou et al. [54] | Generic | 3D periodic unit cells | Fiber direction along the global z-axis | Active two-phase composite material (UMAT Abaqus) (14 parameters) | Uniaxial loading | In vitro passive and active stress-strain response measurement (tibialis anterior) |
Clemen et al. [55] | Biceps | 1 healthy subject, 3D geometries from MRI data | Parallel fiber distribution in a single direction | Active transversely isotropic hyperelastic material | Isometric contraction | Measured indentation data |
Table 6.
References | Muscles | Geometries | Fiber architecture | Constitutive laws | Simulation | Validation |
---|---|---|---|---|---|---|
Gladilin et al. [56] | 20 facial muscles | 1 healthy subject, 3D geometries from MRI data | Fiber tangent interpolation using B-spline | Active fibrous material with heuristic model construction | Facial mimics (happiness, disgust) | No |
Röhrle and Pullan [57] | Masseter | 3D geometries from the Visible Human Project | Parallel fiber distribution using anatomical-based approximation | Active hyperelastic, incompressible, and transversely isotropic material (9 constants) | Mastication | Comparison with literature |
Beldie et al. [22] | 20 facial muscles | 1 patient, 3D geometries from MRI data | Parallel fiber distribution in a single direction | Active, quasi-incompressible, transversely isotropic, and hyperelastic material (13 parameters) (UMAT LS-DYNA) | Maxillofacial surgery | In vivo postsurgery data (skin envelop) |
Nazari et al. [58] | 10 paired facial muscles | 1 subject, 3D geometries from CT data | Curvature-driven cable elements | Active transversely isotropic material (ANSYS) | Dynamic orofacial movements | Measured velocity profile and the acoustic signal |
Wu et al. [26] | 20 facial muscles | 1 healthy subject, 3D geometries from MRI data | Fiber angle interpolation by piecewise linear functions | Active heterogeneous force-drivenhyperelastic material | Facial expressions | Skin deformation from the structured-light scanner |
Fan et al. [59] | 2 paired zygomaticus major | 1 healthy subject, 3D geometries from MRI data | Parallel fiber distribution in muscle mean-line direction | Active transversely isotropic, hyperelastic, and quasi-incompressiblematerial (5 parameters) (VUMAT Abaqus) | Facial mimics | In vivo MRI-based displacement |
2.3.1. Modeling Strategies
Two modeling strategies have been commonly adopted. The first one focuses on the modeling of only the mechanical aspect of skeletal muscles [22, 26, 36–39, 41–48, 53–59] while the second approach performs the coupling between electrical and mechanical aspects to develop an electromechanical model [21, 49, 50]. Mechanical formulation has taken only the force-length relationship into consideration. Active and passive muscle states have been mathematically formulated using exponential and quadratic functions. The integration of electrical aspect into mechanical formulation requires the mathematical formulation of action potential generation through ion channels at cell membrane level. The integration of some chemical components has been also done [51]. The number of parameters is significantly important in active skeletal muscle models. Note also that the number of model parameters rapidly increases when more biophysical phenomena are included into constitutive laws. The number of parameters ranges from 5 to 20 parameters [48, 51, 59]. The values of these model parameters and material constants are commonly set up in an empirical manner. Data assumption is always performed, especially in the case of human muscle modeling. One study attempted to measure in vivo data related to contraction amplitude to reduce uncertainty in parameter space and then used it to more accurately reproduce the physical behavior of muscle contraction [59]. Parameter identification was also performed using literature data for the level of stretch-induced fascicle activation [52]. Note that common outcomes of active muscle materials are muscle stress/stretch and strains at fiber and whole muscle levels. Other outcomes include muscle activation level and force-velocity relationship. Membrane potential is also estimated with electromechanical models.
2.3.2. Muscle and Fiber Architecture
Despite the complexity in model formulation and evaluation, active muscle modeling has been commonly performed for a large range of muscles including generic muscle tissue [36, 37, 43, 54], brachialis [35], rectus femoris [38, 46], levator ani [40], biceps brachii [23, 39, 55], gastrocnemius [41, 42, 53], tibialis anterior [44, 47, 49–51], biceps femoris longhead [45], soleus [46, 53], ventral interior lateral muscle [48], lumbar spine muscles [52], and facial muscles [22, 26, 56–59]. Geometrical models of skeletal muscles have been reconstructed from medical imaging (CT and MRI) [22, 23, 26, 38, 45, 50, 53–59]. However, some studies also used ideal 3D geometries to represent the skeletal muscles [36, 37, 43, 44, 47–49, 51, 54].
The definition of fiber architecture is a particular characteristic of the active muscle modeling. Several approaches have been proposed. Parallel fiber distribution in a single direction [22, 37, 39, 41, 42, 44, 46, 48, 51, 54, 55, 59] or at a specific pennation angle [23, 43, 49] has been commonly performed. Bipennate fiber orientation has been also proposed [38]. The definition of fiber according to loading direction has been performed [47]. Fusiform fiber distribution has been established in some models [23, 50]. In particular, mapping technique from different fiber templates showed the important effect of fiber definition in model outcomes [45]. Other approaches like circularly directed and transversely oriented fibers [36] or fiber tangent interpolation using B-spline [56] or curvature-driven cable elements [58] or fiber angle interpolation using piecewise linear functions [26] have been also proposed. Ultrasound images have been used to measure fascicle orientation [53].
2.3.3. Loading Scenarios
Current simulations of active skeletal muscles relate to basic loading scenarios. Isometric activation has been simulated in some studies [36, 50, 51, 55]. Shortening and lengthening have been studied [35, 39, 43, 45, 47, 48, 51]. Shear and deformation in several planes have been also performed [37, 41, 42, 46]. Standing posture and lying position were also simulated [52]. In particular, some studies have attempted to simulate the contribution of active skeletal muscle in the generation of a dynamic movement like knee flexion [38] or plantar flexion [53] or mastication [57] or orofacial movement [58] or facial mimics and expressions [26, 56, 59]. A simulation of surgical gesture on the face has been also performed [22].
2.3.4. Implementation
The implementation of active skeletal muscle models requires specific programming skills. There are no existing commercial finite element programs or solvers allowing to provide active skeletal muscle material. This material is available in FEBio (Musculoskeletal Research Laboratories (MRL), University of Utah, USA), an open source program [60]. The use of the most widely used finite element programs like Abaqus or ANSYS requires the development of user-defined material subroutines (UMAT) [22, 54, 58, 59]. Complex model formulations may be also implemented with other FE codes like nonlinear NIKED [39] or PAK [41] or CMISS [38]. It is important to note that the information related to the computational time and cost is unavailable in the most of published models.
2.3.5. Validation
Mathematical modeling of biological tissues and systems is meaningful only when the model outcome is quantitatively validated in a systematic way. Most of the developed active skeletal muscle models have been validated against literature data [36, 37, 43, 49, 50, 57] or measured data in in vivo conditions [22, 26, 39, 41, 42, 44, 47, 53–55, 58, 59]. However, there are still some proposed models without validation efforts [23, 35, 38, 45, 46, 48, 56]. Data used for validation purpose covers a large range of types such as length-force relationship, stress-strain relationship, velocity profile, and shape deformation. It is important to note that the acquisition of accurate in vivo measurements at fascicle and whole muscle levels remains a challenge. In particular, in vivo human muscle force and stress may not be measured in a noninvasive manner leading to the limited validation capacity in the current continuum muscle models. Moreover, parameter calibration and identification for active muscle material suffer from the lack of experimental data. Among the developed models, outside shape deformation is usually used as an indirect measurement for validation purpose [22, 26, 41, 42, 59]. This information is commonly acquired from imaging data.
Different mathematical formulations of the active muscle material have been developed and proposed in the literature. Models with mechanical behavior have been developed and calibrated for different loading scenarios. Simulation outcomes are fairly consistent with experimental data. This choice is mostly accepted by the continuum muscle modeling community. Thus, the mechanical model of active muscle material could be used and extended for further investigations related to the musculoskeletal biomechanics of the human body [39, 41, 55]. Electromechanical formation has been recently proposed but significant efforts dealing with model calibration and parameter identification need to be done before their use in real application, especially in clinical applications [23, 49]. Moreover, it is important to emphasize that several studies suffered from the lack of systematic validation for the active behavior of the skeletal muscle models [23, 35, 38, 40, 45, 48]. Thus, it is difficult to evaluate the modeling accuracy and outcome precision according to the specific purposes of these studies.
2.4. Summary
Passive skeletal muscle modeling involves the use of classical mechanical materials ranging from the simplest one (e.g., linear elastic) to more complex ones (e.g., hyperelastic). Thus, the modeling effort could be optimized when no active muscle behavior is required. In particular, the use of hyperelastic isotropic material based on the Mooney-Rivlin model is an acceptable approximation of the nonlinear behavior of skeletal muscle while keeping a cheaper computational cost. However, how to set up the accurate and reliable values of model parameters remains a challenging issue, especially in the case of more complex constitutive laws [21, 34, 61].
Regarding active skeletal muscle modeling, phenomenological and biophysical modeling approaches are the most widely used to establish respective constitutive laws. Phenomenological modeling attempted to describe mathematically empirical relationships of biological phenomena inside the skeletal muscle. These relationships are consistent with fundamental theory, but they are not directly derived from theory [62–64]. Measured values are usually required to define these relationships. Biophysical modeling [65, 66] establishes mathematical formalizations of the physical properties of the skeletal muscle system. Note that current active muscle models are classified into two categories: mechanical models and electromechanical models. Mechanical models describe the force distribution, internal tissue loading, and shape deformation of skeletal muscle. Electromechanical models allow the electrophysiological aspects of fibers to be integrated into mechanical formulation. It is important to note that electromechanical formulation is the most relevant muscle model. This coupling allows the integration of action potential propagation behavior from the brain to the muscle fibers to be performed. Thus, novel parameters (e.g., stimulus current, transmembrane potential, and intracellular and extracellular conductivity) have been incorporated into the mechanical model formulation [38, 67]. The reported ranges of values for main mechanical and electromechanical model parameters are depicted in Table 7.
Table 7.
Parameters | Ranges of values | References |
---|---|---|
Passive Mooney-Rivlin material parameters | c 1 = c2 = 0.01MPa | Röhrle [68] |
Activation level | α = [0 → 1] | Blemker et al. [39]; Röhrle and Pullan [57] |
Constant Cauchy stress in passive part | σ passive ff = 0.3MPa | Röhrle and Pullan [57] |
Constant Cauchy stress in active part | σ active ff = 0.3MPa | Röhrle and Pullan [57] |
Optimal fiber stretch length | λ ofl = 1.4 | Blemker et al. [39]; Röhrle and Pullan [57] |
Maximal contractile stress | σ = 0.03 MPa | Röhrle [68] |
Peak stress | σ 0 = [0.46 0.6688]MPa | Martins et al. [35]; Toumanidou and Noailly [52]; Fan et al. [59] |
Maximum isometric stress | σ max = [0.22 − 0.3]MPa | Tang et al. [41]; Blemker et al. [39] |
Resting calcium level | Ca0 = 0.01μM | Fernandez et al. [38] |
Intracellular calcium concentration | [Ca2+]max = 2.5mM | Fernandez et al. [38] |
Intracellular conductivity | σ i = 0.6mS mm−1 | Fernandez et al. [38] |
Extracellular conductivity | σ e = 0.6mS mm−1 | Fernandez et al. [38] |
Surface-to-volume ratio of the cell | A m = 80mm−1 | Fernandez et al. [38] |
Capacitance of the cell membrane | C m = 0.009μF mm−2 | Fernandez et al. [38] |
Geometrical representation of the whole muscle and fiber representation have been achievable using medical imaging. Outside muscle shapes are usually regular. Meshed models have been generated directly from medical images with a good accuracy due to the outside shape simplicity of the skeletal muscle [38, 45, 59]. Hence, there is no need for specific meshing refinement and improvement. All 2D or 3D muscle models have been meshed using classical meshing algorithm and process. Regarding the upper and lower limb muscles, most of the developed models have been simulated with a single muscle configuration [38, 39, 51]. Only few studies incorporated multiple muscles into a system level [53, 69]. However, multiple muscle configuration is commonly performed for facial modeling [26, 56]. Model parameter identification has been performed in some 2D studies [28, 29]. Simulations of active and passive skeletal muscle behaviors have been performed in a large range of cases from simple loading (e.g., isometric activation and contraction) to complex loading (e.g., impact simulations, injury mechanisms). Developed muscle models have been carefully validated using literature data related to muscle length-force relationship [37, 51] and experimental data related to muscle length [39], deformation shape [26, 41, 42, 59], stress and strain relationship [44, 54], or stress response [47].
One specific point to note relates to the progressive developments of some research groups to improve the muscle rheological models. An example of such improvement deals with the improvement of loading scenarios and implementation code [41, 42]. Another example is the improvement of model scale from one scale to multiple scale formulations with more complex biophysical phenomena [49, 51, 57]. The simulation of muscle coordination mechanism with more muscles is also an updated outcome from single-muscle simulation [69]. In fact, under the complexity of skeletal muscle physiology, a progressive modeling strategy is a good choice to advance the understanding of the continuum muscle biomechanics.
3. Trends and Limitations of Current Continuum Models of Skeletal Muscles
3.1. Trends of Current Continuum Models of Skeletal Muscles
Trends of current skeletal muscle modeling relate to 3D accurate representation of the entire skeletal muscle using medical imaging techniques, in vivo experiments for parameter identification in passive muscle modeling and model validation, and the integration of several coupled biophysical phenomena into the mathematical formulation.
With the current progresses of biomedical knowledge and information and communication technology (ICT), the use of medical imaging techniques to develop subject/patient specific finite element models of the musculoskeletal system has become a customized approach [70–72]. Medical imaging modalities like MRI and CT scans have been used for accurately reconstructing the 3D entire muscle geometries. Note that an experienced operator with deep anatomical knowledge is required to perform the complex segmentation task for some specific muscles like facial muscles [59]. In fact, image-based muscle modeling has become a customized approach.
Mechanical (e.g., indentation) tests have been commonly performed for parameter identification in passive skeletal muscle models [28, 29]. Most of the developed models have been validated against literature data and experimental measurements ranging from stress-strain relationship to detailed deformation pattern. Note that outside shape deformation could be used as an appropriate metric for comparison between model outcome and measurement.
Mathematical description of skeletal muscle behaviors has been an intensive research interest during the last century. Among the landmark studies, the experimental work performed by Hill [1] allows many phenomenological and biophysical models of skeletal muscles to be developed and tested under different physiological and pathophysiological conditions. Finite elastic theory has been adopted to develop 3D continuum models of skeletal muscles including intrinsic activation mechanism. Hyperelasticity and viscoelasticity have been widely considered and integrated into current models. Thus, viscous and elastic characteristics when undergoing deformation have been described to exhibit time-dependent strain. Single-scale and multiscale models have been also proposed. Note that multiscale muscle models allow understanding of muscle behaviors at macroscopic scale (e.g., shape deformation) while accounting for structural and mechanical properties (e.g., sarcomere length change or fiber stretch) at smaller scales. Electrophysiological aspects of muscle contraction mechanism have been coupled with mechanical components to reproduce skeletal muscle behaviors in a more realistic manner.
3.2. Limitations of Current Continuum Models of Skeletal Muscles
Parameter identification for active muscle materials, definition of real fiber distribution, data assumption, and limited simulation case studies are drawbacks of the current skeletal muscle modeling.
Despite the accurate and more realistic representation of the skeletal muscle, active constitutive laws have faced a complex challenge of parameter identification [73–75]. In particular, multiscale and electromechanical materials require a great number of parameters to be calibrated and identified. However, there are no existing active 3D continuum muscle models with fully calibrated and identified parameters.
The activation and contraction behaviors of skeletal muscles depend on their shapes including circular (e.g., orbicularis oris muscle), convergent (e.g., pectoralis major muscle), unipennate (e.g., extensor digitorium muscle), nonfusiform parallel (e.g., sactorius muscle), bipennate (e.g., rectus femoris muscle), parallel-fusiform (e.g., biceps brachii muscle), and multipennate (e.g., deltoid muscle) ones. Moreover, fiber shape patterns link directly to failure behaviors in case of muscle fatigue and rupture. Thus, a realistic fiber architecture needs to be established for each modeled muscle. However, current continuum muscle models suffer from fiber representation simplification or no consideration in passive constitutive laws for fiber architecture definition. A potential mapping approach with different fiber architecture templates has been proposed [39]. However, the ideal characteristic of the template limits the representation according to real and detailed fiber distribution. Moreover, the 3D geometries of spinal muscles are practically difficult to obtain, even if medical imaging data could be used. Due to the deep location and multisegment architecture characteristics, these muscles were modeled with fascicle network modeling [52]. This approach is commonly used in rigid multibody modeling [14]. This is one of the main reasons why muscle modeling in the thoracolumbar region of the spine is underexplored according to the upper and lower limb muscles in which the acquisition of detailed information at fascicle and whole muscle levels is commonly feasible. The same remark is noted for the neck muscles [76–78]. Regarding facial muscles, only detailed information at the whole muscle level is available [26, 59]. Thus, further studies need to be investigated to get more detailed information at the fascicle level for these facial muscles.
In addition, data assumption and data estimation using a heuristic approach have been commonly performed leading to the impossible determination of accuracy level of proposed models. For example, contraction amplitude was assumed due to the impractical decomposition of muscle length change into elastic and contractile parts [59]. Moreover, activation level was empirically defined for each muscle [26]. Furthermore, a large range of constitutive constants and values have been used, for example, the values used in hyperelastic material based on Mooney-Rivlin formulation [26, 31, 32]. In particular, the determination of input values for active muscle constitutive models is completely empiric and assumed [23, 36–38, 41, 46–51, 53–55, 57].
In addition, a limited range of simulation case studies has been performed using current muscle models. Simple loading cases such as isometric activation and contraction or shortening and lengthening processes have been investigated. These simulations focus only on the basic understanding of skeletal muscle behavior in physiological conditions. In fact, the application of skeletal muscle models in real cases studies especially in pathophysiological conditions still remains a challenging objective to be achieved.
4. Recommendations for Future Researches
Skeletal muscle composition includes mostly water (around 80%), fat, and collagenous tissues. This complex living tissue has been modeled as an anisotropic, viscoelastic, inhomogeneous, nearly incompressible material with large deformation [35, 39, 41, 44, 57]. Moreover, the integration of fibers and their activation mechanism make the modeling task of skeletal muscle remains an open research challenge from experimental and numerical perspectives. To improve the current 3D continuum models, new recommendations deal with the incorporation of multimodal data derived from medical imaging, the integration of more biophysical phenomena, and model reproducibility. Accounting for data uncertainty in skeletal muscle modeling will be also a challenging issue. It is important to note that these recommendations were done based on the best of our knowledge, some aspects may be already achieved in the literature. Consequently, these recommendations should be considered with updated literature review by using more specific keywords.
4.1. Incorporation of Multimodal Data Derived from Medical Imaging for Skeletal Muscle Modeling
Imaging techniques like MRI-based ones (classical, cine phase contrast, dynamic, elastography), CT, ultrasound, or optical microendoscopy should be investigated to provide morphological (e.g., fiber and sarcomere length), mechanical (e.g., shear modulus, viscosity), and functional (e.g., contraction velocity) properties of skeletal muscles for enhancing model formulation and validation [79–83]. Thus, a systematic multiscale characterization of the skeletal muscle to provide a single coherent and consistent data set should to be performed. In particular, diffusion tensor imaging opens a new avenue for tracking and reconstructing the fiber distribution in an in vivo and realistic way [84, 85]. Thus, robust data processing protocols (e.g., model registration from multimodal and multiscale data or real-time tracking of muscle fiber distribution and contraction velocity) will be also needed to cope with new multimodal data extraction. All these multiscale and multimodal data will lead to robust model formulation, validation, and parameter identification.
In addition, there is no existing experimental technique to measure muscle deformation, stress, and forces in a noninvasive manner. Hence, new original and innovative techniques and measuring protocols need to be developed to make these measurements possible for enhancing model validation. The measurement of contractile properties of the skeletal muscle in in vivo conditions at protein level using high-speed atomic force microscopy (HS-AFM) [86] requires more investigations to elucidate the fundamental activation behavior of skeletal muscles. Finally, the control mechanisms in the spinal cord, peripheral, and central nervous system needs to be characterized to elucidate the neural excitability characteristics and function.
4.2. Integration of More Biophysical Phenomena
Despite a large range of physical phenomena that existed in current models, all physiological aspects of skeletal muscles are not fully integrated (e.g., lack of muscle remodeling mechanism). Mathematical formulations of new aspects could be investigated. For example, the release mechanism of inorganic phosphate in the formation process of the dominant force-generating cross-bridge state should be incorporated to describe the mechanochemical events of the energy-transducing mechanism [6]. Moreover, the integration of muscle oxidative capacity [10] will lead to a more reliable simulation of the skeletal muscle in physiological conditions. Furthermore, the consideration of muscle remodeling mechanism will make constitutive laws more realistic for muscle damage simulation and recovery mechanics [87–89]. The coupling between multiscale modeling and additive manufacturing technology should be done to design biomimetic muscle-like material reproducing skeletal muscle behaviors in a more realistic manner. In addition, even if the electromechanical model of the skeletal muscle has already incorporated the action potential generation mechanism, some missing processes like progressive motor unit (MU) recruitment in time and space should be included to describe more accurately the muscle activation behavior [5]. All these perspectives could be implemented using new user-defined material subroutines and parameter identification should be performed with new experimental data.
4.3. Model Reproducibility
The modeling of skeletal muscles is a complex engineering task. The reproducibility of developed models will rapidly advance the knowledge and applications of skeletal muscle biomechanics [90, 91]. However, there are no existing open access muscle models. Muscle material has been available in FEBio FE computing code but it requires significant modeling efforts to use. Moreover, only mechanical behavior is taken into consideration in this material. Consequently, a common model development guideline needs to be established and developed models should be publically available in open repositories for the muscle modeling community to test and reuse them. In particular, the use of commercial FE code like Abaqus requires the development of complex user-defined material subroutines (e.g., UMAT or VUMAT). There are several research groups developing their models by using this approach [35, 52, 54, 59]. Thus, a future action to share the developed subroutines may advance rapidly the efforts done by each group. Then, the continuum muscle modeling community could benefit from this sharing strategy to achieve a high level of accuracy and physiological meaning of the skeletal muscle models.
4.4. Uncertainty Quantification in Skeletal Muscle Modeling
It is well known that the more complex constitutive laws lead to an increasing number of parameters. Due to the use of data assumption (e.g., empiric definition of muscle activation level [26] or simplification of muscle contraction amplitude [59]), data uncertainties should be taken into consideration in numerical muscle modeling and simulation. Thus, probabilistic muscle modeling and simulation should be performed to provide more reliable outcomes [92, 93]. In particular, random uncertainty due to the variability of muscle intrinsic properties and human errors (intersubject, intrasubject, interoperator, and intraoperator) should be modeled. Moreover, epistemic uncertainty due to the modeling hypothesis and limited experiments needs to be accounted for estimating the confidence level of the simulation outcome under a specific modeling purpose.
5. Conclusions
Skeletal muscle modeling plays an important role in the understanding of locomotion function of the human body in physiological and pathophysiological conditions. The choice of an appropriate material to model skeletal muscle under a specific condition remains a challenging issue. This review provides, for the first time, a holistic view of current continuum models of skeletal muscles to identify potential gaps of these models according to the real physiology of the skeletal muscle. This opens new avenues for improving skeletal muscle modeling in the framework of in silico medicine.
Conflicts of Interest
The authors declare that there is no conflict of interest related to this work.
References
- 1.Hill A. V. The Heat of shortening and the dynamic constants of muscle. Proceedings of the Royal Society of London B. 1938;126(843):136–195. doi: 10.1098/rspb.1938.0050. [DOI] [Google Scholar]
- 2.Metzger J., Moss R. Calcium-sensitive cross-bridge transitions in mammalian fast and slow skeletal muscle fibers. Science. 1990;247(4946):1088–1090. doi: 10.1126/science.2309121. [DOI] [PubMed] [Google Scholar]
- 3.Tsugorka A., Rios E., Blatter L. Imaging elementary events of calcium release in skeletal muscle cells. Science. 1995;269(5231):1723–1726. doi: 10.1126/science.7569901. [DOI] [PubMed] [Google Scholar]
- 4.Sartorelli V., Fulco M. Molecular and cellular determinants of skeletal muscle atrophy and hypertrophy. Science Signaling. 2004;2004(244):p. re11. doi: 10.1126/stke.2442004re11. [DOI] [PubMed] [Google Scholar]
- 5.De Luca C. J. The use of surface electromyography in biomechanics. Journal of Applied Biomechanics. 1997;13(2):135–163. doi: 10.1123/jab.13.2.135. [DOI] [Google Scholar]
- 6.Hibberd M., Dantzig J., Trentham D., Goldman Y. Phosphate release and force generation in skeletal muscle fibers. Science. 1985;228(4705):1317–1319. doi: 10.1126/science.3159090. [DOI] [PubMed] [Google Scholar]
- 7.Lopez J. R., Wanek L. A., Taylor S. R. Skeletal muscle: length-dependent effects of potentiating agents. Science. 1981;214(4516):79–82. doi: 10.1126/science.6974399. [DOI] [PubMed] [Google Scholar]
- 8.Stockdale F. E. DNA synthesis in differentiating skeletal muscle cells: initiation by ultraviolet light. Science. 1971;171(3976):1145–1147. doi: 10.1126/science.171.3976.1145. [DOI] [PubMed] [Google Scholar]
- 9.Cole R. Myoglobin function in exercising skeletal muscle. Science. 1982;216(4545):523–525. doi: 10.1126/science.7071598. [DOI] [PubMed] [Google Scholar]
- 10.Wu H., Kanatous S. B., Thurmond F. A., et al. Regulation of mitochondrial biogenesis in skeletal muscle by CaMK. Science. 2002;296(5566):349–352. doi: 10.1126/science.1071163. [DOI] [PubMed] [Google Scholar]
- 11.Llewellyn M. E., Barretto R. P. J., Delp S. L., Schnitzer M. J. Minimally invasive high-speed imaging of sarcomere contractile dynamics in mice and humans. Nature. 2008;454(7205):784–788. doi: 10.1038/nature07104. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Noble M. I., Pollack G. H. Molecular mechanisms of contraction. Circulation Research. 1977;40(4):333–342. doi: 10.1161/01.RES.40.4.333. [DOI] [PubMed] [Google Scholar]
- 13.Erdemir A., McLean S., Herzog W., van den Bogert A. J. Model-based estimation of muscle forces exerted during movements. Clinical biomechanics. 2007;22(2):131–154. doi: 10.1016/j.clinbiomech.2006.09.005. [DOI] [PubMed] [Google Scholar]
- 14.Dao T. T. Rigid musculoskeletal models of the human body systems: a review. Journal of Musculoskeletal Research. 2016;19(3, article 1630001) doi: 10.1142/S0218957716300015. [DOI] [Google Scholar]
- 15.Zajac F. E. Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. Critical Reviews in Biomedical Engineering. 1989;17(4):359–411. [PubMed] [Google Scholar]
- 16.Savkur R. S., Philips A. V., Cooper T. A. Aberrant regulation of insulin receptor alternative splicing is associated with insulin resistance in myotonic dystrophy. Nature Genetics. 2001;29(1):40–47. doi: 10.1038/ng704. [DOI] [PubMed] [Google Scholar]
- 17.McNally E. M., MacLeod H. Therapy insight: cardiovascular complications associated with muscular dystrophies. Nature Clinical Practice Cardiovascular Medicine. 2005;2(6):301–308. doi: 10.1038/ncpcardio0213. [DOI] [PubMed] [Google Scholar]
- 18.Gorgey A. S., Dudley G. A. Spasticity may defend skeletal muscle size and composition after incomplete spinal cord injury. Spinal Cord. 2008;46(2):96–102. doi: 10.1038/sj.sc.3102087. [DOI] [PubMed] [Google Scholar]
- 19.Pelletier C. A., Hicks A. L. The length–tension relationship of human dorsiflexor and plantarflexor muscles after spinal cord injury. Spinal Cord. 2010;48(3):202–206. doi: 10.1038/sc.2009.106. [DOI] [PubMed] [Google Scholar]
- 20.Kortman H. G., Veldink J. H., Drost G. Positive muscle phenomena—diagnosis, pathogenesis and associated disorders. Nature Reviews Neurology. 2012;8(2):97–107. doi: 10.1038/nrneurol.2011.226. [DOI] [PubMed] [Google Scholar]
- 21.Barbarino G. G., Jabareen M., Trzewik J., Nkengne A., Stamatas G., Mazza E. Development and validation of a three-dimensional finite element model of the face. Journal of Biomechanical Engineering. 2009;131(4, article 041006) doi: 10.1115/1.3049857. [DOI] [PubMed] [Google Scholar]
- 22.Beldie L., Walker B., Lu Y., Richmond S., Middleton J. Finite element modelling of maxillofacial surgery and facial expressions—a preliminary study. The International Journal of Medical Robotics and Computer Assisted Surgery. 2010;6(4):422–430. doi: 10.1002/rcs.352. [DOI] [PubMed] [Google Scholar]
- 23.Böl M., Weikert R., Weichert C. A coupled electromechanical model for the excitation-dependent contraction of skeletal muscle. Journal of the Mechanical Behavior of Biomedical Materials. 2011;4(7):1299–1310. doi: 10.1016/j.jmbbm.2011.04.017. [DOI] [PubMed] [Google Scholar]
- 24.Chabanas M., Luboz V., Payan Y. Patient specific finite element model of the face soft tissues for computer-assisted maxillofacial surgery. Medical Image Analysis. 2003;7(2):131–151. doi: 10.1016/S1361-8415(02)00108-1. [DOI] [PubMed] [Google Scholar]
- 25.Kim H., Jürgens P., Weber S., Nolte L. P., Reyes M. A new soft-tissue simulation strategy for cranio-maxillofacial surgery using facial muscle template model. Progress in Biophysics and Molecular Biology. 2010;103(2-3):284–291. doi: 10.1016/j.pbiomolbio.2010.09.004. [DOI] [PubMed] [Google Scholar]
- 26.Wu T., Hung A., Mithraratne K. Generating facial expressions using an anatomically accurate biomechanical model. IEEE Transactions on Visualization and Computer Graphics. 2014;20(11):1519–1529. doi: 10.1109/TVCG.2014.2339835. [DOI] [PubMed] [Google Scholar]
- 27.Büchler P., Ramaniraka N. A., Rakotomanana L. R., Iannotti J. P., Farron A. A finite element model of the shoulder: application to the comparison of normal and osteoarthritic joints. Clinical Biomechanics. 2002;17(9-10):630–639. doi: 10.1016/S0268-0033(02)00106-7. [DOI] [PubMed] [Google Scholar]
- 28.Avril S., Bouten L., Dubuis L., Drapier S., Pouget J.-F. Mixed experimental and numerical approach for characterizing the biomechanical response of the human leg under elastic compression. Journal of Biomechanical Engineering. 2010;132(3, article 031006) doi: 10.1115/1.4000967. [DOI] [PubMed] [Google Scholar]
- 29.Affagard J. S., Bensamoun S. F., Feissel P. Development of an inverse approach for the characterization of in vivo mechanical properties of the lower limb muscles. Journal of Biomechanical Engineering. 2014;136(11, article 111012) doi: 10.1115/1.4028490. [DOI] [PubMed] [Google Scholar]
- 30.Zöllner A. M., Pok J. M., McWalter E. J., Gold G. E., Kuhl E. On high heels and short muscles: a multiscale model for sarcomere loss in the gastrocnemius muscle. Journal of Theoretical Biology. 2015;365:301–310. doi: 10.1016/j.jtbi.2014.10.036. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Wang Y., Downie S., Wood N., Firmin D., Xu X. Y. Finite element analysis of the deformation of deep veins in the lower limb under external compression. Medical Engineering & Physics. 2013;35(4):515–523. doi: 10.1016/j.medengphy.2012.06.019. [DOI] [PubMed] [Google Scholar]
- 32.Lee W., Won B. H., Cho S. W. Finite element modeling for predicting the contact pressure between a foam mattress and the human body in a supine position. Computer Methods in Biomechanics and Biomedical Engineering. 2016;20(1):104–117. doi: 10.1080/10255842.2016.1203421. [DOI] [PubMed] [Google Scholar]
- 33.Hedenstierna S., Halldin P. How does a three-dimensional continuum muscle model affect the kinematics and muscle strains of a finite element neck model compared to a discrete muscle model in rear-end, frontal, and lateral impacts. Spine. 2008;33(8):E236–E245. doi: 10.1097/BRS.0b013e31816b8812. [DOI] [PubMed] [Google Scholar]
- 34.Wheatley B. B., Odegard G. M., Kaufman K. R., Haut Donahue T. L. A case for poroelasticity in skeletal muscle finite element analysis: experiment and modeling. Computer Methods in Biomechanics and Biomedical Engineering. 2016;20(6):598–601. doi: 10.1080/10255842.2016.1268132. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Martins J. A. C., Pires E. B., Salvado R., Dinis P. B. A numerical model of passive and active behavior of skeletal muscles. Computer Methods in Applied Mechanics and Engineering. 1998;151(3-4):419–433. doi: 10.1016/S0045-7825(97)00162-X. [DOI] [Google Scholar]
- 36.Johansson T., Meier P., Blickhan R. A finite-element model for the mechanical analysis of skeletal muscles. Journal of Theoretical Biology. 2000;206(1):131–149. doi: 10.1006/jtbi.2000.2109. [DOI] [PubMed] [Google Scholar]
- 37.Yucesoy C. A., Koopman B. H. F. J. M., Huijing P. A., Grootenboer H. J. Three-dimensional finite element modeling of skeletal muscle using a two-domain approach: linked fiber-matrix mesh model. Journal of Biomechanics. 2002;35(9):1253–1262. doi: 10.1016/S0021-9290(02)00069-6. [DOI] [PubMed] [Google Scholar]
- 38.Fernandez J. W., Buist M. L., Nickerson D. P., Hunter P. J. Modelling the passive and nerve activated response of the rectus femoris muscle to a flexion loading: a finite element framework. Medical Engineering & Physics. 2005;27(10):862–870. doi: 10.1016/j.medengphy.2005.03.009. [DOI] [PubMed] [Google Scholar]
- 39.Blemker S. S., Pinsky P. M., Delp S. L. A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii. Journal of Biomechanics. 2005;38(4):657–665. doi: 10.1016/j.jbiomech.2004.04.009. [DOI] [PubMed] [Google Scholar]
- 40.d’Aulignac D., Martins J. A. C., Pires E. B., Mascarenhas T., Jorge R. M. N. A shell finite element model of the pelvic floor muscles. Computer Methods in Biomechanics and Biomedical Engineering. 2005;8(5):339–347. doi: 10.1080/10255840500405378. [DOI] [PubMed] [Google Scholar]
- 41.Tang C. Y., Tsui C. P., Stojanovic B., Kojic M. Finite element modelling of skeletal muscles coupled with fatigue. International Journal of Mechanical Sciences. 2007;49(10):1179–1191. doi: 10.1016/j.ijmecsci.2007.02.002. [DOI] [Google Scholar]
- 42.Tang C. Y., Zhang G., Tsui C. P. A 3D skeletal muscle model coupled with active contraction of muscle fibres and hyperelastic behaviour. Journal of Biomechanics. 2009;42(7):865–872. doi: 10.1016/j.jbiomech.2009.01.021. [DOI] [PubMed] [Google Scholar]
- 43.Chi S.-W., Hodgson J., Chen J.-S., et al. Finite element modeling reveals complex strain mechanics in the aponeuroses of contracting skeletal muscle. Journal of Biomechanics. 2010;43(7):1243–1250. doi: 10.1016/j.jbiomech.2010.01.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Lu Y. T., Zhu H. X., Richmond S., Middleton J. A visco-hyperelastic model for skeletal muscle tissue under high strain rates. Journal of Biomechanics. 2010;43(13):2629–2632. doi: 10.1016/j.jbiomech.2010.05.030. [DOI] [PubMed] [Google Scholar]
- 45.Rehorn M. R., Blemker S. S. The effects of aponeurosis geometry on strain injury susceptibility explored with a 3D muscle model. Journal of Biomechanics. 2010;43(13):2574–2581. doi: 10.1016/j.jbiomech.2010.05.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Sharafi B., Blemker S. S. A micromechanical model of skeletal muscle to explore the effects of fiber and fascicle geometry. Journal of Biomechanics. 2010;43(16):3207–3213. doi: 10.1016/j.jbiomech.2010.07.020. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Ehret A. E., Bol M., Itskov M. A continuum constitutive model for the active behaviour of skeletal muscle. Journal of the Mechanics and Physics of Solids. 2011;59(3):625–636. doi: 10.1016/j.jmps.2010.12.008. [DOI] [Google Scholar]
- 48.Paetsch C., Trimmer B. A., Dorfmann A. A constitutive model for active–passive transition of muscle fibers. International Journal of Non-Linear Mechanics. 2012;47(2):377–387. doi: 10.1016/j.ijnonlinmec.2011.09.024. [DOI] [Google Scholar]
- 49.Röhrle O., Davidson J. B., Pullan A. J. A physiologically based, multi-scale model of skeletal muscle structure and function. Frontiers in Physiology. 2012;3 doi: 10.3389/fphys.2012.00358. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Hernández-Gascón B., Grasa J., Calvo B., Rodríguez J. F. A 3D electro-mechanical continuum model for simulating skeletal muscle contraction. Journal of Theoretical Biology. 2013;335:108–118. doi: 10.1016/j.jtbi.2013.06.029. [DOI] [PubMed] [Google Scholar]
- 51.Heidlauf T., Röhrle O. A multiscale chemo-electro-mechanical skeletal muscle model to analyze muscle contraction and force generation for different muscle fiber arrangements. Frontiers in Physiology. 2014;5 doi: 10.3389/fphys.2014.00498. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Toumanidou T., Noailly J. Musculoskeletal modeling of the lumbar spine to explore functional interactions between back muscle loads and intervertebral disk multiphysics. Frontiers in Bioengineering and Biotechnology. 2015;3 doi: 10.3389/fbioe.2015.00111. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Kinugasa R., Yamamura N., Sinha S., Takagi S. Influence of intramuscular fiber orientation on the Achilles tendon curvature using three-dimensional finite element modeling of contracting skeletal muscle. Journal of Biomechanics. 2016;49(14):3592–3595. doi: 10.1016/j.jbiomech.2016.09.014. [DOI] [PubMed] [Google Scholar]
- 54.Spyrou L. A., Agoras M., Danas K. A homogenization model of the Voigt type for skeletal muscle. Journal of Theoretical Biology. 2017;414:50–61. doi: 10.1016/j.jtbi.2016.11.018. [DOI] [PubMed] [Google Scholar]
- 55.Clemen C. B., Benderoth G. E. K., Schmidt A., Hübner F., Vogl T. J., Silber G. Human skeletal muscle behavior in vivo: finite element implementation, experiment, and passive mechanical characterization. Journal of the Mechanical Behavior of Biomedical Materials. 2017;65:679–687. doi: 10.1016/j.jmbbm.2016.09.030. [DOI] [PubMed] [Google Scholar]
- 56.Gladilin E., Zachow S., Deuflhard P., Hege H. -C. Anatomy- and physics-based facial animation for craniofacial surgery simulations. Medical and Biological Engineering and Computing. 2004;42(2):167–170. doi: 10.1007/BF02344627. [DOI] [PubMed] [Google Scholar]
- 57.Röhrle O., Pullan A. J. Three-dimensional finite element modelling of muscle forces during mastication. Journal of Biomechanics. 2007;40(15):3363–3372. doi: 10.1016/j.jbiomech.2007.05.011. [DOI] [PubMed] [Google Scholar]
- 58.Nazari M. A., Perrier P., Chabanas M., Payan Y. Simulation of dynamic orofacial movements using a constitutive law varying with muscle activation. Computer Methods in Biomechanics and Biomedical Engineering. 2010;13(4):469–482. doi: 10.1080/10255840903505147. [DOI] [PubMed] [Google Scholar]
- 59.Fan A. X., Dakpé S., Dao T. T., Pouletaut P., Rachik M., Ho Ba Tho M. C. MRI-based finite element modeling of facial mimics: a case study on the paired zygomaticus major muscles. Computer Methods in Biomechanics and Biomedical Engineering. 2017;20(9):919–928. doi: 10.1080/10255842.2017.1305363. [DOI] [PubMed] [Google Scholar]
- 60.Maas S. A., Ellis B. J., Ateshian G. A., Weiss J. A. FEBio: finite elements for biomechanics. Journal of Biomechanical Engineering. 2012;134(1, article 11005) doi: 10.1115/1.4005694. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Van Loocke M., Lyons C. G., Simms C. K. Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling. Journal of Biomechanics. 2008;41(7):1555–1566. doi: 10.1016/j.jbiomech.2008.02.007. [DOI] [PubMed] [Google Scholar]
- 62.Braby L. A. Phenomenological models. Basic Life Sciences. 1991;58:339–361. doi: 10.1007/978-1-4684-7627-9_12. [DOI] [PubMed] [Google Scholar]
- 63.Gillissen J. J. J., Tabaei S. R., Cho N.-J. A phenomenological model of the solvent-assisted lipid bilayer formation method. Physical Chemistry Chemical Physics. 2016;18(35):24157–24163. doi: 10.1039/C6CP04816A. [DOI] [PubMed] [Google Scholar]
- 64.Mancini S., Mège R. M., Sarels B., Strale P. O. A phenomenological model of cell-cell adhesion mediated by cadherins. Journal of Mathematical Biology. 2017;74(7):1657–1678. doi: 10.1007/s00285-016-1072-7. [DOI] [PubMed] [Google Scholar]
- 65.Badoual M., Zou Q., Davison A. P., et al. Biophysical and phenomenological models of multiple spike interactions in spike-timing dependent plasticity. International Journal of Neural Systems. 2006;16(2):79–97. doi: 10.1142/S0129065706000524. [DOI] [PubMed] [Google Scholar]
- 66.Ling A., Huang Y., Shuai J., Lan Y. Channel based generating function approach to the stochastic Hodgkin-Huxley neuronal system. Scientific Reports. 2016;6(1) doi: 10.1038/srep22662. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67.Fernandez J., Zhang J., Heidlauf T., et al. Multiscale musculoskeletal modelling, data--model fusion and electromyography-informed modelling. Interface Focus. 2016;6(2, article 20150084) doi: 10.1098/rsfs.2015.0084. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Röhrle O. Simulating the electro-mechanical behavior of skeletal muscles. Computing in Science & Engineering. 2010;12(6):48–58. doi: 10.1109/MCSE.2010.30. [DOI] [Google Scholar]
- 69.Röhrle O., Sprenger M., Schmitt S. A two-muscle, continuum-mechanical forward simulation of the upper limb. Biomechanics and Modeling in Mechanobiology. 2017;16(3):743–762. doi: 10.1007/s10237-016-0850-x. [DOI] [PubMed] [Google Scholar]
- 70.Blemker S. S., Asakawa D. S., Gold G. E., Delp S. L. Image-based musculoskeletal modeling: applications, advances, and future opportunities. Journal of Magnetic Resonance Imaging. 2007;25(2):441–451. doi: 10.1002/jmri.20805. [DOI] [PubMed] [Google Scholar]
- 71.Vahdati A., Walscharts S., Jonkers I., Garcia-Aznar J. M., Vander Sloten J., van Lenthe G. H. Role of subject-specific musculoskeletal loading on the prediction of bone density distribution in the proximal femur. Journal of the Mechanical Behavior of Biomedical Materials. 2014;30:244–252. doi: 10.1016/j.jmbbm.2013.11.015. [DOI] [PubMed] [Google Scholar]
- 72.Dao T. T., Rassineux A., Charleux F., Ho Ba Tho M. C. A robust protocol for the creation of patient specific finite element models of the musculoskeletal system from medical imaging data. Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization. 2014;3(3):136–146. doi: 10.1080/21681163.2014.896226. [DOI] [Google Scholar]
- 73.Bernakiewicz M., Viceconti M. The role of parameter identification in finite element contact analyses with reference to orthopaedic biomechanics applications. Journal of Biomechanics. 2002;35(1):61–67. doi: 10.1016/S0021-9290(01)00163-4. [DOI] [PubMed] [Google Scholar]
- 74.Benoussaad M., Poignet P., Hayashibe M., Azevedo-Coste C., Fattal C., Guiraud D. Experimental parameter identification of a multi-scale musculoskeletal model controlled by electrical stimulation: application to patients with spinal cord injury. Medical & Biological Engineering & Computing. 2013;51(6):617–631. doi: 10.1007/s11517-013-1032-y. [DOI] [PubMed] [Google Scholar]
- 75.Reutlinger C., Bürki A., Brandejsky V., Ebert L., Büchler P. Specimen specific parameter identification of ovine lumbar intervertebral discs: on the influence of fibre-matrix and fibre-fibre shear interactions. Journal of the Mechanical Behavior of Biomedical Materials. 2014;30:279–289. doi: 10.1016/j.jmbbm.2013.11.019. [DOI] [PubMed] [Google Scholar]
- 76.Van Ee C. A., Nightingale R. W., Camacho D. L., et al. Tensile properties of the human muscular and ligamentous cervical spine. Stapp Car Crash Journal. 2000;44:85–102. doi: 10.4271/2000-01-SC07. [DOI] [PubMed] [Google Scholar]
- 77.Brolin K., Halldin P., Leijonhufvud I. The effect of muscle activation on neck response. Traffic Injury Prevention. 2005;6(1):67–76. doi: 10.1080/15389580590903203. [DOI] [PubMed] [Google Scholar]
- 78.Zhang Q. H., Teo E. C., Ng H. W. Development and validation of a CO-C7 FE complex for biomechanical study. Journal of Biomechanical Engineering. 2005;127(5):729–735. doi: 10.1115/1.1992527. [DOI] [PubMed] [Google Scholar]
- 79.Albracht K., Arampatzis A., Baltzopoulos V. Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo. Journal of Biomechanics. 2008;41(10):2211–2218. doi: 10.1016/j.jbiomech.2008.04.020. [DOI] [PubMed] [Google Scholar]
- 80.Debernard L., Robert L., Charleux F., Bensamoun S. F. Analysis of thigh muscle stiffness from childhood to adulthood using magnetic resonance elastography (MRE) technique. Clinical Biomechanics. 2011;26(8):836–840. doi: 10.1016/j.clinbiomech.2011.04.004. [DOI] [PubMed] [Google Scholar]
- 81.Abe T., Loenneke J. P., Thiebaud R. S. Morphological and functional relationships with ultrasound measured muscle thickness of the lower extremity: a brief review. Ultrasound. 2015;23(3):166–173. doi: 10.1177/1742271X15587599. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82.Bilston L. E., Tan K. Measurement of passive skeletal muscle mechanical properties in vivo: recent progress, clinical applications, and remaining challenges. Annals of Biomedical Engineering. 2015;43(2):261–273. doi: 10.1007/s10439-014-1186-2. [DOI] [PubMed] [Google Scholar]
- 83.Clarke E. C., Martin J. H., d’entremont A. G., Pandy M. G., Wilson D. R., Herbert R. D. A non-invasive, 3D, dynamic MRI method for measuring muscle moment arms in vivo: demonstration in the human ankle joint and Achilles tendon. Medical Engineering & Physics. 2015;37(1):93–99. doi: 10.1016/j.medengphy.2014.11.003. [DOI] [PubMed] [Google Scholar]
- 84.Heemskerk A. M., Sinha T. K., Wilson K. J., Ding Z., Damon B. M. Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters. Magnetic Resonance in Medicine. 2009;61(2):467–472. doi: 10.1002/mrm.21819. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Brandão S., Parente M., Silva E., et al. Pubovisceralis muscle fiber architecture determination: comparison between biomechanical modeling and diffusion tensor imaging. Annals of Biomedical Engineering. 2017;45(5):1255–1265. doi: 10.1007/s10439-016-1788-y. [DOI] [PubMed] [Google Scholar]
- 86.Kodera N., Ando T. The path to visualization of walking myosin V by high-speed atomic force microscopy. Biophysical Reviews. 2014;6(3-4):237–260. doi: 10.1007/s12551-014-0141-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 87.Narici M. V., Flueck M., Koesters A., et al. Skeletal muscle remodeling in response to alpine skiing training in older individuals. Scandinavian Journal of Medicine & Science in Sports. 2011;21(1):23–28. doi: 10.1111/j.1600-0838.2011.01338.x. [DOI] [PubMed] [Google Scholar]
- 88.Krüger M., Kötter S. Titin, a central mediator for hypertrophic signaling, exercise-induced mechanosignaling and skeletal muscle remodeling. Frontiers in Physiology. 2016;7(76) doi: 10.3389/fphys.2016.00076. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 89.Dziki J. L., Giglio R. M., Sicari B. M., et al. The effect of mechanical loading upon extracellular matrix bioscaffold-mediated skeletal muscle remodeling. Tissue Engineering Part A. 2018;24(1-2):34–46. doi: 10.1089/ten.TEA.2017.0011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 90.McDougal R., Bulanova A., Lytton W. Reproducibility in computational neuroscience models and simulations. IEEE Transactions on Biomedical Engineering. 2016;63(10):2021–2035. doi: 10.1109/TBME.2016.2539602. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 91.Peng G. C. Moving toward model reproducibility and reusability. IEEE Transactions on Biomedical Engineering. 2016;63(10):1997–1998. doi: 10.1109/TBME.2016.2603418. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 92.Dao T. T., Tho M.-C. H. B. Assessment of parameter uncertainty in rigid musculoskeletal simulation using a probabilistic approach. Journal of Musculoskeletal Research. 2015;18(3, article 1550013) doi: 10.1142/S021895771550013X. [DOI] [Google Scholar]
- 93.Dao T. T., Ho Ba Tho M.-C. A consistent data fusion approach for uncertainty quantification in rigid musculoskeletal simulation. Journal of Mechanics in Medicine and Biology. 2017;17(4, article 1750062) doi: 10.1142/S0219519417500622. [DOI] [Google Scholar]