Abstract
Objective
The aim of the present study was to assess seven-year clinical outcomes of biodegradable polymer coated Supralimus sirolimus-eluting stent (S-SES) [Sahajanand Medical Technologies Pvt. Ltd., Surat, India] in real-world patients with coronary artery disease.
Methods
This observational, retrospective study was carried out in all 346 consecutive enrolled patients who underwent percutaneous coronary intervention (PCI) with the S-SES, between April 2008 and December 2009, at a single center. We analyzed major adverse cardiac events (MACE) [a composite of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) and target vessel revascularization (TVR)] as primary outcomes at seven-year follow-up.
Results
Out of 346 patients, seven-year follow-up was obtained in 327 (94.5%) patients and hence results were analyzed for 327 patients. At seven-year, MACE occurred in 41 (12.5%) patients, consisting of 23 (7.0%) cardiac deaths, 14 (4.3%) TLR, and 4 (1.2%) TVR. The incidence of late stent thrombosis was observed in 3 (0.9%) patients. At follow-up of seven-year, the cumulative event-free survival was found to be 84.7% by Kaplan-Meier method.
Conclusions
The present study demonstrated satisfactory and sustained seven-year clinical outcomes as evidenced by the low rates of MACE and ST for the biodegradable polymer coated S-SES.
Keywords: Coronary artery lesion, Biodegradable polymer, Percutaneous coronary intervention, Sirolimus-eluting stent
1. Introduction
First-generation drug-eluting stents (DES) with durable polymers significantly reduced the risk of target lesion revascularisation (TLR) compared to bare metal stents (BMS).1, 2 However, the delayed arterial healing associated with DES has led to an increase in the rates of late and very late stent thrombosis (ST) and rebound of restenosis, termed as late catch-up.3 Although ST and restenosis are multifactorial in cause, durable polymer coatings may play an important role in their etiology. Several histopathological studies indicated that the durable polymer coatings of DES, which were associated with hypersensitivity reactions directed against the polymer, localized vascular inflammation, apoptosis of smooth muscle cells, and thrombogenic reactions, may play important roles in late or very late ST.4, 5 Therefore, there is increasing interest in designing a new generation of DES with a biodegradable polymer that may overcome these potential drawbacks of durable polymer DES.
Newer generation DESs were developed featuring biodegradable polymers that release limus analogues at lower dosages.6, 7 These refinements resulted not only in a remarkable reduction in the risk of ST compared with early generation DESs but also improved efficacy (lower risk of repeat revascularization) and safety (lower risk of death and myocardial infarction [MI]).8 However, the clinical evidences of such advantages in real-world practice, especially those with long-term follow-up, are limited.9, 10, 11 Furthermore, very few long-term clinical studies (up to 7-year) related to sirolimus-eluting stent (SES) are there and most of these are related to SES with durable polymers. In addition, there is limited long-term clinical data related to biodegradable polymer coated SES.
The Supralimus sirolimus-eluting stent (S-SES) [Sahajanand Medical Technologies Pvt. Ltd., Surat, India] uses stainless steel as its stent platform, which is coated with a biodegradable polymer to deliver sirolimus. The S-SES has been available for clinical use since 2005 and the clinical safety and effectiveness of the S-SES is already established in various clinical studies. 12, 13, 14, 15, 16 The present study was aimed at determining the clinical outcome of the S-SES at seven-year, which is the longest available follow-up of the biodegradable polymer coated SES technology.
2. Methods
2.1. Study design and patient population
This observational, retrospective study was carried out in all 346 consecutive enrolled patients who underwent percutaneous coronary intervention (PCI) with the S-SES between April 2008 and December 2009, at the Shree B.D. Mehta Mahavir Heart Institute, Surat, India. In this study, the list of all patients who had been implanted with the S-SES during this period was procured. Therefore, even though, it was retrospective analysis, all consecutive patients were included in the study. Since, there was no plan at the time of performing the procedure to conduct seven-year follow up evaluation; there was no selection bias (cherry picking) at the time of implanting the S-SES. During this period, no other stent of any other brand of same technology (sirolimus drug with biodegradable polymer) was available. All other DESs used during this period were SES or paclitaxel-eluting stents (PES) with durable polymers. The S-SES constituted 45.7% of total DESs used during this period. The seven-year follow-up was conducted by an independent clinical research organization (Therapeutic Medical Service, Surat, India) and was supervised by an independent cardiologist from a remote institute between June 2016 and August 2016. The study was approved by the institutional ethics committee.
2.2. Description of the study stent
The S-SES has stainless steel as its stent platform having a strut thickness of 80 μm with biodegradable polymers and drug load of 1.4 μg/mm2. About 70% of drug is released within 7 days and remaining drug is released over a period of 48 days. The coating layer comprises of the drug Sirolimus blended together with biodegradable polymeric matrix. This matrix includes blend of hydrophobic and hydrophilic biodegradable polymers – Poly L-Lactide, 50/50 Poly DL Lactide-co-Glycolide and Polyvinyl Pyrrolidone to control the drug elution from stent coating.
2.3. Interventional procedures and adjunctive medication
Coronary interventional procedures and adjuvant medications were performed according to standard guidelines. All patients received dual antiplatelet therapy (DAPT) including a loading dose of aspirin (300 mg) and clopidogrel (600 mg). The procedural anticoagulation was achieved with heparin. However, the intra-procedural administration of glycoprotein IIb/IIIa inhibitor was at the investigator’s discretion. All patients were advised to maintain DAPT (aspirin; 75–300 mg daily indefinitely and clopidogrel; 75 mg daily for at least 12 months) after the procedure.
2.4. Data acquisition and follow-up
According to the standard data-management procedures in our institute, data were collected on demographics, cardiovascular history, clinical risk factors, and treatment characteristics for all patients undergoing PCI. As part of study end points, the seven-year follow-up was conducted by an independent clinical research organization and was supervised by an independent cardiologist from a remote institute between June 2016 and August 2016. Follow-up data of all patients were obtained at visits to outpatient clinics or, if not feasible, by telephone follow-up. Those patients, who did not come for follow-up visit, were again followed after 15 days. During the follow-up contacts, information about patients’ clinical condition, adverse events, hospitalizations, and changes to concomitant (cardiac and antiplatelet) medications were collected.
2.5. Outcomes and definitions
We analyzed major adverse cardiac events (MACE) [a composite of cardiac death, MI, target lesion revascularization (TLR) and target vessel revascularization (TVR)] as primary outcomes and estimated event-free survival by the Kaplan-Meier method at seven-year of follow-up. Any death due to undetermined cause was reported as cardiac death. Q-wave MI was considered, when there was development of new Q-wave of more than 0.04 s in two or more adjoining leads along with increase in cardiac markers like Troponin I or T, creatine kinase (CK) or MB isoform. Non-Q-wave MI was considered when there was more than three times elevation in CK levels along with elevation in MB isoform and Troponin markers T or I without development of new Q-waves. TLR was considered when there was stenosis in treated segment (5 mm proximal and 5 mm distal edges). TVR was considered when there was stenosis in any segment of the treated vessel and had to undergo revascularization with either PCI or coronary artery bypass grafting (CABG). We also analyzed the incidence of ST as a safety end point during follow-up period. ST was defined according to criteria of Academic Research Consortium (ARC) with its timing being classified as early (within 24 h of the index procedure), late (occurred between 30 days to 1-year of the index procedure), or very late ST (occurred beyond 1-year of the index procedure), while its degree of certainty was classified as definite (if confirmed angiographically), probable (the patient had a target vessel–related MI or died of a coronary event), or possible (any unexplained death from 30 days after intracoronary stenting).
2.6. Statistical analysis
Data are presented using descriptive statistical methods. Continuous variables were presented as mean ± standard deviation, whereas categorical variables were expressed as percentages. All data were processed using the Statistical Package for Social Sciences, version 15 (SPSS, Chicago, IL, USA).
3. Results
3.1. Baseline and lesion characteristics
Out of 346 patients, seven-year follow-up was obtained in 327 (94.5%) patients and hence results were analyzed for 327 patients. The mean age of patients was 56.0 ± 11.4 years, and 40.1% (131/327), 34.9% (114/327) and 31.2% (102/327) had diabetes, hypertension and hypercholesterolaemia, respectively. The baseline demographics and clinical characteristics of all the treated patients are described in Table 1. A total of 386 target lesions were treated, including 11 (2.8%) unprotected left mains, 24 (6.2%) bifurcations, and 18 (4.7%) total occlusions. Among overall population most lesions (35.8%; 138/386) were located in the left anterior descending artery and 237 (61.4%) of 386 lesions were type B2/C, according to the American College of Cardiology/American Heart Association classification scheme. A total of 386 S-SES were implanted at index procedure (1.18 stents per patient) with an average diameter and total stent length of 3.0 ± 0.4 mm and 25.04 ± 9.1 mm, respectively. No patients had an additional dissimilar DES implanted but 11 patients had an additional short BMS (8–10 mm length) implanted to cover border dissections. The detailed lesion and procedural characteristics are described in Table 2.
Table 1.
Demographic and clinical characteristics at baseline (n = 327 patients).
Characteristics | Data |
---|---|
Demographic characteristics | |
Age, (mean ± SD, years) | 56.0 ± 11.4 |
Male, n (%) | 269 (82.3%) |
Risk factors | |
Current smoking, n (%) | 62 (19.0%) |
Hypertension, n (%) | 114 (34.9%) |
Hypercholesterolemia, n (%) | 102 (31.2%) |
Diabetes mellitus, n (%) | 131 (40.1%) |
Cardiac history | |
Prior MI, n (%) | 20 (6.1%) |
Prior CABG, n (%) | 4 (1.2%) |
Prior PCI, n (%) | 18 (5.5%) |
Clinical presentation | |
Stable angina, n (%) | 93 (28.4%) |
Unstable angina, n (%) | 54 (16.5%) |
STEMI, n (%) | 112 (34.3%) |
NSTEMI, n (%) | 68 (20.8%) |
Cardiogenic shock, n (%) | 8 (2.4%) |
CABG: coronary artery bypass grafting; MI: myocardial infarction; NSTEMI: non ST-segment elevation myocardial infarction; PCI: percutaneous coronary intervention; STEMI: ST-segment elevation myocardial infarction.
Table 2.
Lesion and procedural characteristics.
Characteristics | Data |
---|---|
Number of patients, n | 327 |
Number of lesion, n | 386 |
Target vessel location | |
Left anterior descending artery, n (%) | 138 (35.8%) |
Right coronary artery, n (%) | 122 (31.6%) |
Left circumflex artery, n (%) | 113 (29.3%) |
Left main artery, n (%) | 11 (2.8%) |
Saphenous vein graft, n (%) | 2 (0.5%) |
Lesion classification (ACC/AHA score) | |
Type A, n (%) | 62 (16.1%) |
Type B1, n (%) | 87 (22.5%) |
Type B2, n (%) | 99 (25.6%) |
Type C, n (%) | 138 (35.8%) |
Disease severity | |
Moderate to severe calcification, n (%) | 26 (6.7%) |
Bifurcation, n (%) | 24 (6.2%) |
Total occlusion, n (%) | 18 (4.7%) |
Total number of stent, n | 386 |
Number of stents per patient, mm (mean ± SD) | 1.18 ± 0.4 |
Average stent length, mm (mean ± SD) | 25.04 ± 9.1 |
Average stent diameter, mm (mean ± SD) | 3.0 ± 0.4 |
ACC/AHA: American College of Cardiology/American Heart Association.
3.2. Clinical outcomes
Table 3 summarizes the clinical outcomes. At 7-year, MACE occurred in 41 (12.5%) patients, consisting of 23 (7.0%) cardiac deaths (9 sudden deaths, 5 from heart failure, 8 from acute MI, 1 perioperatively for CABG), 14 (4.3%) TLR, and 4 (1.2%) TVR. The incidence of late ST was observed in 3 (0.9%) patients during 7-year follow-up with an annual thrombotic rate of 0.1% and 0.0004% ST per patient-year. Non-cardiac deaths were reported in 6 (1.8%) patients. At seven-year follow-up, the cumulative event-free survival was found to be 84.7% by Kaplan-Meier method (Fig. 1). A total of 259 (79.2%) patients were still on DAPT at seven-year with no major bleeding complication requiring readmission or blood transfusion.
Table 3.
Clinical outcomes at seven-year follow-up (n = 327 patients).
Outcomes | 0-1-year | >1-year | 0-7-year |
---|---|---|---|
Death, n (%) | 7 (2.1%) | 22 (6.7%) | 29 (8.9%) |
Cardiac death, n (%) | 6 (1.8%) | 17 (5.2%) | 23 (7.0%) |
Non-cardiac death, n (%) | 1 (0.3%) | 5 (1.5%) | 6 (1.8%) |
Myocardial infarction, n (%) | 6 (1.8%) | 4 (1.2%) | 10 (3.1%) |
Target lesion revascularization, n (%) | 3 (0.9%) | 11 (3.4%) | 14 (4.3%) |
Target vessel revascularization, n (%) | 2 (0.6%) | 2 (0.6%) | 4 (1.2%) |
Stent thrombosis, n (%) | 3 (0.9%) | 0 (0) | 3 (0.9%) |
Major adverse cardiac events, n (%) | 11 (3.4%) | 30 (9.2%) | 41 (12.5%) |
All events, n (%) | 15 (4.6%) | 35 (10.7%) | 50 (15.3%) |
Fig. 1.
Kaplan-Meier curve of cumulative event-free survival over seven-year.
4. Discussion
Several studies had demonstrated the safety and efficacy of biodegradable polymer based DES in selected patients.9, 17, 18, 19 However, the validity of extrapolating those results to daily practice had remained uncertain because the follow-up period of most studies were not long enough to elucidate the consequences after completed degradation of a biodegradable polymer. To our knowledge, the present study is the first longest real-world experience of biodegradable polymer coated SES technology. In the present study, the S-SES has shown satisfactory and sustained seven-year clinical outcomes during daily interventional practice, which suggests the long-term clinical benefits of biodegradable polymer-based SES.
DESs were designed with the primary purpose of inhibiting restenosis after PCI. Early data from randomized trials have confirmed the efficacy of such devices in reducing restenosis and TLR compared with BMS. However, long-term (two years or longer) observations show the ‘late catch-up’ phenomenon of first-generation DES, namely, an increase of rates of very late restenosis or TLR.20, 21, 22 Furthermore, previous studies have suggested that first-generation DES could delay local vessel healing and increase the risk of potentially fatal late ST,23 an adverse event that has been at least partly attributed to the durable polymer coatings of DES. As a result, new generation DESs with biodegradable polymer coatings have been recently developed as an alternative to reduce the risk of late ST. In this context, the S-SES was developed using biodegradable polymer-based, SES technology. The clinical safety and effectiveness of the S-SES was already established in various clinical studies.12, 13, 14, 15, 16
Further recently, a pooled analysis of individual patient data from the three major randomized trials comparing biodegradable polymer and durable polymer DES (ISAR TEST 3, ISAR TEST 4 and LEADERS Trials) with an extended follow-up to 4-year, showed for the first time a significant reduction in terms of definite ST in favor of biodegradable polymer DES.24 These conclusions received further support by the recent release of 5-year follow-up data of the LEADERS Trial, which confirm a significant superiority of biodegradable polymer DES compared with durable polymer DES, driven primarily by the reduction in the incidence of very late ST.25 In this study, the S-SES demonstrates a very low rate of ST (0.9%) at seven-year, which is lower than the CREATE study, 5-year clinical outcomes of biodegradable polymer coated sirolimus-eluting EXCEL stent, which reported 2.4% ST at 5-year follow-up.26
Furthermore, El-Hayek et al. reported an important meta-analysis of 16 randomized controlled trials comprising 19,886 patients, investigating the safety and efficacy of biodegradable polymer coated DES compared with current second-generation durable polymer coated DES.27 In that analysis, there were no differences in TVR, cardiac death, MI, or ST rates between biodegradable polymer coated DES and durable polymer coated DES. However, the outcomes of 11,866 patients from only 6 randomized controlled trials were studied beyond one year of follow-up (mean duration 26 months) in that meta-analysis. The results of the present study provide an insight into the long-term (seven-year) clinical outcomes for patients undergoing PCI with the biodegradable polymer coated S-SES which is the longest available follow-up of the biodegradable polymer coated SES technology.
In addition, in the present study, patient population had higher rates of hypertension (34.9%), hypercholesterolemia (31.2%), type B2/C (61.4%) lesions, and total occluded (4.7%) lesions. The combination of these factors makes the patient population for this study unusually complex. Regardless of this individuality, the present study reported a low rate of TLR (4.3%) and MACE (12.5%) at seven-year follow-up compared to available long-term (5-year) follow-up results of randomized trials with durable polymer based DES (Table 4). 21, 28, 29, 30, 31, 32, 33, 34, 35 This numeric differences in long-term clinical outcomes between the present study and other DES studies imply there are potential benefits of biodegradable polymer based DES in reducing late catch-up.
Table 4.
Long-term (5-year) follow-up results of randomised trials.
Trial Name | DES | Drug | Polymer Type | Patients | Follow-up Time | MACE (%) | TLR (%) | ST (%) |
---|---|---|---|---|---|---|---|---|
RAVEL Trial28 | Cypher (Cordis, Johnson & Johnson) |
Sirolimus | Durable Polymer | 120 | 5-year | 25.8 | 7.4 | 3.3 |
SIRIUS Trial29 | Cypher (Cordis, Johnson & Johnson) |
Sirolimus | Durable Polymer | 533 | 5-year | 20.3 | 9.4 | 3.9 |
TAXUS II Trial21 | Taxus (Boston Scientific) |
Paclitaxel | Durable Polymer | 131 | 5-year | 20.4 | 16.6 | 2.7 |
TAXUS IV Trial30 | Taxus Express2 (Boston Scientific) |
Paclitaxel | Durable Polymer | 651 | 5-year | 24.0 | 9.1 | 2.2 |
ENDEAVOR II Study31 | Endeavor (Medtronic Vascular) |
Zotarolimus | Durable Polymer | 597 | 5-year | 15.4 | 7.5 | 0.9 |
ENDEAVOR III Study32 | Endeavor (Medtronic Vascular) |
Zotarolimus | Durable Polymer | 307 | 5-year | 14 | 8.1 | 0.7 |
ENDEAVOR IV Study33 | Endeavor (Medtronic Vascular) |
Zotarolimus | Durable Polymer | 722 | 5-year | 17.9 | 7.8 | 4.6 |
SPIRIT FIRST Trial34 | Xience V (Abbott Vascular) |
Everolimus | Durable Polymer | 24 | 5-year | 16.7 | 8.3 | 0 |
SPIRIT III Trial35 | Xience V (Abbott Vascular) |
Everolimus | Durable Polymer | 621 | 5-year | 13.7 | 8.6 | 1.4 |
The present study was conducted with the aim to collect real-world long-term data of the S-SES. Although limited by its single arm, non-randomized, retrospective study design, it had certain robust features: 1) there was no plan at the time of performing the procedure to conduct 7-year follow up evaluation and total number of implanted S-SES constituted large percentage of total DESs used during this period. Thus, it was an unselected population and largely devoid of selection bias; 2) all consecutively enrolled patients who underwent PCI with the S-SES were considered for this study; 3) after seven-year, a very high percentage (94.5%) of follow-up was available; 4) the seven-year follow-up was conducted by an independent clinical research organization and was supervised by an independent cardiologist from a remote institute who was not involved in the original procedures.
5. Limitations
There are several limitations in the present study. First, this study was a single arm, non-randomized, retrospective study that did not include a control group. Second, the present study included a small number of patients. Third, the study had follow-up without any mandatory objective assessment for recurrent myocardial ischemia. However, asymptomatic MIs are typically associated with lesser clinical significance than symptomatic events, suggesting that the under-reporting of ischaemic events in the present study has a limited impact on the conclusions. Despite these limitations, this study provides an insight into the long-term (seven-year) clinical outcomes for patients undergoing PCI with the biodegradable polymer coated S-SES.
6. Conclusions
The results of the present study demonstrate satisfactory and sustained seven-year clinical outcomes for the biodegradable polymer coated S-SES in treating patients in real-world settings, with low rates of MACE and ST.
7. Impact on daily practice
Present study demonstrates acceptable seven-year clinical outcomes of the S-SES during daily interventional practice, which suggests the long-term clinical benefits of biodegradable polymer-based SES.
Conflict of interest statement
The authors have no conflicts of interest to declare.
References
- 1.Moses J.W., Leon M.B., Popma J.J. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003;349:1315–1323. doi: 10.1056/NEJMoa035071. [DOI] [PubMed] [Google Scholar]
- 2.Babapulle M.N., Joseph L., Belisle P. A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents. Lancet. 2004;364:583–591. doi: 10.1016/S0140-6736(04)16850-5. [DOI] [PubMed] [Google Scholar]
- 3.Chamie D., Abizaid A., Costa J.R., Jr. Serial angiographic and intravascular ultrasound evaluation to interrogate the presence of late catch-up phenomenon after Cypher(R) sirolimus-eluting stent implantation. Int J Cardiovasc Imaging. 2011;27:867–874. doi: 10.1007/s10554-010-9723-z. [DOI] [PubMed] [Google Scholar]
- 4.Nebeker J.R., Virmani R., Bennett C.L. Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project. J Am Coll Cardiol. 2006;47:175–181. doi: 10.1016/j.jacc.2005.07.071. [DOI] [PubMed] [Google Scholar]
- 5.Virmani R., Guagliumi G., Farb A. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious. Circulation. 2004;109:701–705. doi: 10.1161/01.CIR.0000116202.41966.D4. [DOI] [PubMed] [Google Scholar]
- 6.Piccolo R., Stefanini G.G., Franzone A. Safety and efficacy of resolute zotarolimus-eluting stents compared with everolimus-eluting stents: a meta-analysis. Circ Cardiovasc Interv. 2015;8 doi: 10.1161/CIRCINTERVENTIONS.114.002223. [DOI] [PubMed] [Google Scholar]
- 7.Stefanini G.G., Holmes D.R., Jr. Drug-eluting coronary-artery stents. N Engl J Med. 2013;368:254–265. doi: 10.1056/NEJMra1210816. [DOI] [PubMed] [Google Scholar]
- 8.Windecker S., Stortecky S., Stefanini G.G. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis. BMJ. 2014;348:g3859. doi: 10.1136/bmj.g3859. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Buszman P., Trznadel S., Milewski K. Novel paclitaxel-eluting, biodegradable polymer coated stent in the treatment of de novo coronary lesions: a prospective multicenter registry. Catheter Cardiovasc Interv. 2008;71:51–57. doi: 10.1002/ccd.21392. [DOI] [PubMed] [Google Scholar]
- 10.Han Y., Jing Q., Chen X. Long-term clinical, angiographic, and intravascular ultrasound outcomes of biodegradable polymer-coated sirolimus-eluting stents. Catheter Cardiovasc Interv. 2008;72:177–183. doi: 10.1002/ccd.21600. [DOI] [PubMed] [Google Scholar]
- 11.Windecker S., Serruys P.W., Wandel S. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. Lancet. 2008;372:1163–1173. doi: 10.1016/S0140-6736(08)61244-1. [DOI] [PubMed] [Google Scholar]
- 12.Dani S., Kukreja N., Parikh P. Biodegradable-polymer-based, sirolimus-eluting Supralimus stent: 6-month angiographic and 30-month clinical follow-up results from the series I prospective study. EuroIntervention. 2008;4:59–63. doi: 10.4244/eijv4i1a11. [DOI] [PubMed] [Google Scholar]
- 13.Shetty R., Vivek G., Thakkar A. Experience with biodegradable polymer coated sirolimus-eluting coronary stent system in real-life percutaneous coronary intervention: 24-month data from the manipal-s registry. J Clin Diagn Res. 2013;7:1959–1963. doi: 10.7860/JCDR/2013/5915.3369. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Lemos P.A., Moulin B., Perin M.A. Late clinical outcomes after implantation of drug-eluting stents coated with biodegradable polymers: 3-year follow-up of the PAINT randomised trial. EuroIntervention. 2012;8:117–119. doi: 10.4244/EIJV8I1A18. [DOI] [PubMed] [Google Scholar]
- 15.Lemos P.A., Moulin B., Perin M.A. Randomized evaluation of two drug-eluting stents with identical metallic platform and biodegradable polymer but different agents (paclitaxel or sirolimus) compared against bare stents: 1-year results of the PAINT trial. Catheter Cardiovasc Interv. 2009;74:665–673. doi: 10.1002/ccd.22166. [DOI] [PubMed] [Google Scholar]
- 16.Marchini J.F., Gomes W.F., Moulin B. Very late outcomes of drug-eluting stents coated with biodegradable polymers: insights from the 5-year follow-up of the randomized PAINT trial. Cardiovasc Diagn Ther. 2014;4:480–486. doi: 10.3978/j.issn.2223-3652.2014.12.05. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Ge J., Qian J., Wang X. Effectiveness and safety of the sirolimus-eluting stents coated with bioabsorbable polymer coating in human coronary arteries. Catheter Cardiovasc Interv. 2007;69:198–202. doi: 10.1002/ccd.20926. [DOI] [PubMed] [Google Scholar]
- 18.Wessely R., Kastrati A., Mehilli J. Randomized trial of rapamycin- and paclitaxel-eluting stents with identical biodegradable polymeric coating and design. Eur Heart J. 2007;28:2720–2725. doi: 10.1093/eurheartj/ehm425. [DOI] [PubMed] [Google Scholar]
- 19.Grube E., Sonoda S., Ikeno F. Six-and twelve-month results from first human experience using everolimus-eluting stents with bioabsorbable polymer. Circulation. 2004;109:2168–2171. doi: 10.1161/01.CIR.0000128850.84227.FD. [DOI] [PubMed] [Google Scholar]
- 20.Caixeta A., Leon M.B., Lansky A.J. 5-year clinical outcomes after sirolimus-eluting stent implantation insights from a patient-level pooled analysis of 4 randomized trials comparing sirolimus-eluting stents with bare-metal stents. J Am Coll Cardiol. 2009;54:894–902. doi: 10.1016/j.jacc.2009.04.077. [DOI] [PubMed] [Google Scholar]
- 21.Silber S., Colombo A., Banning A.P. Final 5-year results of the TAXUS II trial: a randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for de novo coronary artery lesions. Circulation. 2009;120:1498–1504. doi: 10.1161/CIRCULATIONAHA.109.849877. [DOI] [PubMed] [Google Scholar]
- 22.Park D.W., Hong M.K., Mintz G.S. Two-year follow-up of the quantitative angiographic and volumetric intravascular ultrasound analysis after nonpolymeric paclitaxel-eluting stent implantation: late catch-up phenomenon from ASPECT Study. J Am Coll Cardiol. 2006;48:2432–2439. doi: 10.1016/j.jacc.2006.08.033. [DOI] [PubMed] [Google Scholar]
- 23.Finn A.V., Nakazawa G., Joner M. Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol. 2007;27:1500–1510. doi: 10.1161/ATVBAHA.107.144220. [DOI] [PubMed] [Google Scholar]
- 24.Stefanini G.G., Byrne R.A., Serruys P.W. Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials. Eur Heart J. 2012;33:1214–1222. doi: 10.1093/eurheartj/ehs086. [DOI] [PubMed] [Google Scholar]
- 25.Serruys P.W., Farooq V., Kalesan B. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial. JACC Cardiovasc Interv. 2013;6:777–789. doi: 10.1016/j.jcin.2013.04.011. [DOI] [PubMed] [Google Scholar]
- 26.Han Y.L., Zhang L., Yang L.X. A new generation of biodegradable polymer-coated sirolimus-eluting stents for the treatment of coronary artery disease: final 5-year clinical outcomes from the CREATE study. EuroIntervention. 2012;8:815–822. doi: 10.4244/EIJV8I7A124. [DOI] [PubMed] [Google Scholar]
- 27.El-Hayek G., Bangalore S., Casso Dominguez A. Meta-analysis of randomized clinical trials comparing biodegradable polymer drug-eluting stent to second-generation durable polymer drug-eluting stents. JACC Cardiovasc Interv. 2017;10:462–473. doi: 10.1016/j.jcin.2016.12.002. [DOI] [PubMed] [Google Scholar]
- 28.Morice M.C., Serruys P.W., Barragan P. Long-term clinical outcomes with sirolimus-eluting coronary stents: five-year results of the RAVEL trial. J Am Coll Cardiol. 2007;50:1299–1304. doi: 10.1016/j.jacc.2007.06.029. [DOI] [PubMed] [Google Scholar]
- 29.Weisz G., Leon M.B., Holmes D.R., Jr. Five-year follow-up after sirolimus-eluting stent implantation results of the SIRIUS (Sirolimus-Eluting Stent in De-Novo Native Coronary Lesions) trial. J Am Coll Cardiol. 2009;53:1488–1497. doi: 10.1016/j.jacc.2009.01.050. [DOI] [PubMed] [Google Scholar]
- 30.Ellis S.G., Stone G.W., Cox D.A. Long-term safety and efficacy with paclitaxel-eluting stents: 5-year final results of the TAXUS IV clinical trial (TAXUS IV-SR: treatment of de novo Coronary disease using a single paclitaxel-eluting stent) JACC Cardiovasc Interv. 2009;2:1248–1259. doi: 10.1016/j.jcin.2009.10.003. [DOI] [PubMed] [Google Scholar]
- 31.Fajadet J., Wijns W., Laarman G.J. Long-term follow-up of the randomised controlled trial to evaluate the safety and efficacy of the zotarolimus-eluting driver coronary stent in de novo native coronary artery lesions: five year outcomes in the ENDEAVOR II study. EuroIntervention. 2010;6:562–567. doi: 10.4244/EIJV6I5A95. [DOI] [PubMed] [Google Scholar]
- 32.Kandzari D.E., Mauri L., Popma J.J. Late-term clinical outcomes with zotarolimus-and sirolimus-eluting stents: 5-year follow-up of the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) JACC Cardiovasc Interv. 2011;4:543–550. doi: 10.1016/j.jcin.2010.12.014. [DOI] [PubMed] [Google Scholar]
- 33.Kirtane A.J., Leon M.B., Ball M.W. The final 5-year follow-up from the ENDEAVOR IV trial comparing a zotarolimus-eluting stent with a paclitaxel-eluting stent. JACC Cardiovasc Interv. 2013;6:325–333. doi: 10.1016/j.jcin.2012.12.123. [DOI] [PubMed] [Google Scholar]
- 34.Wiemer M., Serruys P.W., Miquel-Hebert K. Five-year long-term clinical follow-up of the XIENCE V everolimus eluting coronary stent system in the treatment of patients with de novo coronary artery lesions: the SPIRIT FIRST trial. Catheter Cardiovasc Interv. 2010;75:997–1003. doi: 10.1002/ccd.22428. [DOI] [PubMed] [Google Scholar]
- 35.Gada H., Kirtane A.J., Newman W. 5-year results of a randomized comparison of XIENCE V everolimus-eluting and TAXUS paclitaxel-eluting stents: final results from the SPIRIT III trial (clinical evaluation of the XIENCE V everolimus eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions) JACC Cardiovasc Interv. 2013;6:1263–1266. doi: 10.1016/j.jcin.2013.07.009. [DOI] [PubMed] [Google Scholar]