Abstract
The effect of thickness in multilayer thin-film composite membranes on gas permeation has received little attention to date, and the gas permeances of the organic polymer membranes are believed to increase by membrane thinning. Moreover, the performance of defect-free layers with known gas permeability can be effectively described using the classical resistance in series models to predict both permeance and selectivity of the composite membrane. In this work, we have investigated the Pebax®-MH1657/PDMS double layer membrane as a selective/gutter layer combination that has the potential to achieve sufficient CO2/N2 selectivity and permeance for efficient CO2 and N2 separation. CO2 and N2 transport through membranes with different thicknesses of two layers has been investigated both experimentally and with the utilization of resistance in series models. Model prediction for permeance/selectivity corresponded perfectly with experimental data for the thicker membranes. Surprisingly, a significant decrease from model predictions was observed when the thickness of the polydimethylsiloxane (PDMS) (gutter layer) became relatively small (below 2 µm thickness). Material properties changed at low thicknesses—surface treatments and influence of porous support are discussed as possible reasons for observed deviations.
Keywords: gas separation, membrane, thickness influence, thin-film nanocomposite membranes, flue gas separation, carbon dioxide capture, carbon-neutral energy
1. Introduction
Membranes are considered a potentially effective tool for separation of carbon dioxide (CO2) from gas mixtures. In particular, separation from ubiquitous flue-gas originating from heat-power plants is needed to achieve cost-efficient CO2 capture and prevent global warming [1]. Membrane systems are viewed as competitive to conventional CO2 capture systems due to versatility, relative simplicity, potentially lower energy consumption, and lower capital cost as well as smaller environmental footprint [2]. On the other hand, to succeed in large-scale industrial application, gas separation membranes should satisfy not only high “separation ability” i.e., selectivity towards CO2 (e.g., >40 in post-combustion CO2/N2 separation), but also significantly higher “separation speed” i.e., permeance numbers (>1000 GPU) [3]. A significant number of organic polymer materials have demonstrated suitable values of CO2/N2 selectivity, well exceeding the number required for industrial use. However, at the same time, gas permeability and selectivity in organic polymers follow well-known trade-off behavior resulting in the so-called Robeson upper bound of performance [4]. According to the empirical data published in literature, most organic polymers with high selectivity have considerably low permeability at the same time. As a result, it is quite difficult to fabricate the membranes with satisfactory outcomes using just one separating layer of material in the membrane. The required thicknesses of such separation layers able to achieve the permeances as high as 4000 GPU for CO2 are very thin (<30 nm), and therefore it is unlikely to fabricate such thin films without defects on a large scale [5]. Moreover, a number of negative effects were observed in the layers of such ultimate thickness: accelerated aging, pronounced defect formation, and permeability decrease with thickness [5,6,7]. Thin film composite (TFC) membranes with more complex structures are aiming to overcome these drawbacks. In such membranes, the thin selective layer is most often assembled on a highly gas-permeable polymer layer, the so-called gutter layer, which is previously deposited on the porous support and combined with a mechanical support layer. Utilization of gutter layers provide some advantages to improve the membrane performance. In particular, it is preventing the viscous flow of gas through the minor defects that can be present in the selective layers [8]. Polydimethylsiloxane (PDMS, rubbery polymer) and poly(1-(trimethylsilyl)-1-propyne) (PTMSP, glassy polymer) are two materials most commonly used as gutter layers in TFC membranes, due to their high gas permeability [9]. In recent works, PTMSP of a few micrometer thickness was used as the gutter layer on poly(vinylidene difluoride) (PVDF) to support graphene oxide-ionic liquid [10] or metal-organic framework [11] based selective layers. In contrast, PDMS could be easily used with much smaller thicknesses (down to 100 nm) and has been utilized as a gutter layer on polyacrylonitrile (PAN) porous supports, most often to hold even thinner polymeric or mixed matrix layers [12,13]. However, despite its superior initial bulk permeability, PTMSP demonstrates accelerated aging [14], and therefore PDMS retains almost exclusively used as a gutter layer in the majority of reported TFC membranes for CO2 separation [9].
The family of thermoplastic polyether-block-amides commercially available as Pebax® is a class of polymers well known in the membrane research field. These polymers contain ethylene oxide moieties, which are known for their selectivity of CO2 over other gases such as nitrogen, methane, and even smaller gases like H2 and He [15]. Structurally, these polymers contain polyethylene oxide (PEO) and polyamides nylon-6 or nylon-12 (PA6 and PA12, respectively). Owing to the presence of PA in the structure, Pebax polymers possess excellent mechanical properties while phase-separated PEO domains act as the pathways for the selective gas transport. Within this family, the polymer grade identified as Pebax® MH1657 containing 60 wt% of PEO and 40 wt% polyamide-6 PA6 in its structure is one of the most investigated for selective layer formation in TFC separation membranes for CO2 capture [9]. It possesses high selectivity towards CO2 in both CO2/N2 (ca. 50–70), and CO2/H2 (ca. 10) targeted separations as well as reasonable CO2 permeability (~100 barrer at room temperature).
In this current work, we investigate the double layer membrane composed of Pebax-1657 selective layer and PDMS gutter layer (chemical structures are given in Figure 1) transferred onto porous support to form a composite membrane. Prediction of the double layer membrane permeance and selectivity are calculated using the resistance in series model [16] based on the bulk permeabilities of both polymers. We have fabricated membranes with various thickness combinations for two layers and compared experimental results with the model prediction.
2. Materials and Methods
2.1. Materials
Simple soda-lime glass substrates (3.5 × 3.5 cm) were used for double layer membrane fabrication by spin-coating. Polyhydroxystyrene (PHS, Mw = 11,000, Sigma-Aldrich, St. Louis, MO, USA) was used for the fabrication of a sacrificial layer. A two-component PDMS kit (Sylgard184) was purchased from Dow Corning. Copolymer Pebax® MH1657 (Pebax-1657) containing 60 wt% of poly(ethylene oxide) (PEO) and 40 wt% polyamide-6 (PA6) in its structure was provided by Arkema (Kyoto, Japan) in the form of pellets and used as received for membrane preparation. Hexane (a mixture of isomers, ≥96%) and ethanol were purchased from Wako Pure Chemicals (Osaka, Japan) and used as received. Deionized water (18.3 MΩ cm−1) was obtained by reverse osmosis followed by ion exchange and filtration (Millipore, Direct-QTM, Burlington, MA, USA) and used for substrate washing and solution preparation. The porous support used in this study showed meager resistance to the CO2 and N2 flow (permeances of support ~55,000 GPU for CO2 and ~65,000 GPU for N2, respectively). Therefore, the effect of the porous support can be neglected from resistance model calculations.
2.2. Membrane Fabrication
Thick membranes of both Pebax-1657 and PDMS were fabricated via solution casting onto the Teflon molds. Different PDMS membranes were also fabricated to check the permeability of CO2 and N2 depending on the curing temperature and curing time. Several thick membranes of Pebax-1657 were fabricated to check the reproducibility of bulk permeability and selectivity values.
Thin film composite (TFC) membranes were fabricated according to previous reports [8,17,18] using the procedure schematically depicted in Figure 2. At first glass substrates were washed in water and ethanol, dried by air blowing, and treated with oxygen plasma for 3 min (FA-1, SAMCO, Kyoto, Japan. RF power: 55 W; flow rate of oxygen: 10 sccm; chamber pressure: 20 Pa) to make the substrate surface hydrophilic. A sacrificial layer (SL) was deposited by spin coating of the 15 wt% PHS solution in EtOH on the plasma treated glass (step 2) followed by drying on the hot-plate for 5 min (step 3). Different thicknesses of PDMS layers were deposited on the glass with an SL layer (step 4) by spin-coating the various concentration solutions of PDMS in hexane (from 1.5 v/v% to 30 v/v%). After PDMS spin coating, a silicone ring with a thickness of 500 µm was placed on the PDMS (step 5) and the membrane was cured at 80 °C for 12 h for PDMS crosslinking (step 6). After the completion of the crosslinking, the SL layer was dissolved in EtOH (step 7) to release the freestanding PDMS membrane, which was subsequently removed from EtOH and transferred onto porous support (step 8). For the Pebax-1657 deposition, double layer PDMS/porous support membrane was again physically attached to the glass substrate using adhesive tape. To achieve good adherence of the Pebax-1657 layer to PDMS, a 10 min ozone treatment of the PDMS surface was essential (step 9). Pebax-1657 was spin-coated by using 5 v/v% solution of the polymer in EtOH/H2O (70/30 wt%) mixed solvent (step 10). Finally, the tri-layer TFC membrane was dried (step 11) and was then ready for gas separation tests.
Morphology of the membrane cross-sections was analyzed using field emission scanning electron microscopy (FESEM Hitachi S-5200, 5 kV accelerating voltage). For cross-section observation, the samples were fractured in liquid nitrogen and dried under vacuum. To prevent charge-up by electron beam, samples were coated with a thin platinum layer before observation, deposited using an ion sputter (Hitachi E-1030).
2.3. Gas Permeation Measurement
For the gas permeance measurements membranes were masked with aluminum tape to provide the circle of desired diameter and area (d = 2 cm, S = 3.14 cm2, casted membranes; d = 1 cm, S = 0.79 cm2, TFC membranes). The dry gas (N2, CO2) permeation through the membranes was measured at 25 °C using the GTR-11A/31A gas permeation analysis system (GTR Tec Corp., Kyoto, Japan, operating according to ISO15105-1 B standard) able to measure wide ranges of permeance from very low to moderate values [19]. This system employs a differential-pressure method for testing film permeability with initial vacuum on the permeate side and compressed gas at the feed side, respectively. Total pressure difference was set to 0.2 MPa for all measurements. The sample collection time after vacuuming the permeate side of the membrane was set to 10 min for thick membranes and below 30 s for TFC membranes. The machine is able to measure both pure gas permeability and mixed gas blends as well. In both cases gas chromatograph (GC) is used to measure the amount of permeated gas or gases. The gas collected in the permeation cell is automatically transferred to a GC (Yanaco G3700T, Fukuoka, Japan) which is equipped with a thermal conductivity detector (TCD), and He was used as a carrier gas for sample transport into the machine. Permeance (P) of gases in GPU units (1 GPU = 7.5 × 10−12 m3(STP)/m2·s·Pa) was estimated for membranes of different composition and permeability (p) in barrer units (1 barrer = 10−10 cm3(STP)·cm/cm2·s·cmHg = GPU·µm) was calculated using the membrane thicknesses and permeances (p = P·l). The ideal selectivity between two different gases in a hybrid membrane was calculated using the ratio of the permeabilities of a single gas, αA/B= pA/pB, where pA and pB are the permeabilities of gases A and B, respectively.
2.4. Resistance Model for Gas Permeation Description on Three-Layer System
In this research, the composite membranes consist of three layers: the selective layer (Pebax-1657), the gutter layer (PDMS), and porous substrate as schematically shown in Figure 3. According to the resistance in series model [16], gas transport of a layered membrane can be described as an analogy to the electric current flow in the serial connection of conductors. Each layer provides certain resistance to the gas flow which is proportional to the thickness and inversely proportional to the material permeability and surface area (Equation (1)). In the case of the multi-layer structure, the total resistance will be equal to the sum of resistances originating from each layer (Equation (2)). Therefore, the knowledge of mass transport through each layer separately enables one to predict the gas flow through the composite structure. In many cases, and in this work in particular, the resistance of the porous support layer (Rp) can be neglected so that we can consider only the contribution of the selective layer, Rs (Pebax-1657), and gutter layer, Rg (PDMS).
(1) |
(2) |
(3) |
(4) |
Using Equations (3) and (4), it is possible, in principle, to design a membrane with the desired permeability (pt) and selectivity. In this work, we have considered the CO2 and N2 separation with the double layer Pebax-1657/PDMS membrane because neither of the materials can satisfy the optimal CO2/N2 separation due to trade-off phenomena [4]. Namely, being sufficiently selective to CO2 (α ≈ 64), Pebax-1657 has low CO2 permeability (~100 barrer). In contrast, for PDMS the situation is opposite—CO2 permeability of the polymer is sufficiently high (~3000 barrer), but rather low selectivity (α ≈ 11) is not sufficient for effective CO2/N2 separation. The permeability of carbon dioxide and nitrogen of the double layer structure will be described by Equations (5) and (6), respectively. The ideal selectivity also can be derived by taking the ratio of permeabilities and can be calculated using Equation (7).
(5) |
(6) |
(7) |
where are CO2 permeability, N2 permeability, and selectivity of selective (Pebax-1657) layer, respectively; are CO2 permeability, N2 permeability, and selectivity of gutter (PDMS) layer respectively; are predicted CO2, N2 permeabilities, and selectivity of composite membrane.
Further generalization of the Equations (5)–(7) can be done with the consideration of the ratio between the thicknesses of the gutter and selective layer. If we consider n = lg/ls as a ratio of thicknesses, equations can be rewritten as follows
(8) |
(9) |
Using these two equations, we are generally free to choose the parameters of the double layer membrane to achieve the desired resulting CO2 permeability and CO2/N2 selectivity by varying the thickness ratio between two layers with known gas separation parameters. This work aims to check how close a model prediction would be to the experimental results depending on the thicknesses of the two layers.
3. Results
3.1. Confirmation of the Bulk Permeability Values of PDMS and Pebax-1657
Thick membranes of both polymers were fabricated via solution casting and their permeability towards pure gases was checked using GTR-11A/31A equipment. Due to utilization of rather mild curing temperatures for thin PDMS membranes (80 °C), we first tested how this could affect the bulk PDMS permeability. A recent study has reported that the amount of crosslinker and the PDMS curing temperature can have significant influence on CO2 permeability [20]. However, we did not detect any significant permeability change with three different PDMS curing temperatures. As seen in Figure 4a, no influence of the PDMS cross-linking temperature on the CO2 and N2 permeability was detected and materials with different fabrication conditions gave similar gas transport rates. These values of both CO2 and N2 permeabilities are in good agreement with the reported values in the literature for PDMS [21,22,23,24], considering the measurement temperature. In the case of Pebax-1657, the permeability with different thicknesses (as shown in Figure 4b) was measured, and the results are also reproducible within experimental error. Comparison with the literature indicates that the measured values are close to the range of permeability characteristic for Pebax-1657, which varies in the available literature, namely pCO2 ~ 55–110 barrer and α(CO2/N2) ~ 40–70 [25,26,27,28,29,30].
CO2 and N2 permeability for different conditions/membranes and CO2/N2 selectivity were averaged for both polymers and results summarized in Table 1 and compared with the values from literature for similar materials. Permeability values obtained for thick membranes were used for double layer membrane gas permeability and permeance prediction using the resistance in the series model throughout the study (Equations (8) and (9)).
Table 1.
Material | CO2 Permeability, Barrer | N2 Permeability, Barrer | Ideal Selectivity | Reference |
---|---|---|---|---|
PDMS | 3395 ± 55 | 307 ± 3 | 11 | This work |
3100 a | 290 | 10.7 | [23] | |
3632 a | 330 c | 11 | [24] | |
3800 ± 70 b | 400 ± 10 b | 9.5 | [21] | |
Pebax-1657 | 128 ± 17 | 2.0 ± 0.4 | 64 | This work |
55.8 | 1.4 | 40.2 | [25] | |
80 | 1.1 | 70 | [29] | |
133 | 2.6 c | 52 | [30] |
a Measured at 30 °C, b measured at 35 °C, c Calculated from permeability of CO2 and CO2/N2 selectivity.
3.2. Resistance Model Predictions for Double Layer Pebax-1657/PDMS Membranes
Using the experimentally measured permeability and selectivity values in Equations (8) and (9), we can predict the gas permeability behavior for composite membranes. As shown in the equations, the final permeability and selectivity are not dependent on the thickness of individual layers rather than the ratio of the thicknesses n. With the increase of the ratio, the permeability of the double layer membrane will be smoothly varied between its extreme values, namely, pt = ps when n = 0 and pt = pg when n→∞ as shown in Figure 5. It is interesting to note that the apparent permeability of the double layer membrane according to model prediction goes linearly from Pebax-1657 towards PDMS with the increase of n. This linear behaviour is the straightforward implication of the resistance model: resistances of two layers are simply added to each other. However, when the transition is depicted in usual log-log scale of Robeson plot it follows a complex path and breaks the Robeson upper bound [4], as the materials in the composite membrane share the properties at some values of n (namely from n ≈ 1 until n ≈ 65).
From the practical point of membrane application, it is more interesting to look not at the permeability values but the permeance of the composite membrane depending on the total thickness. Using the prediction of the gas permeability/selectivity performance of the Pebax-1657/PDMS membranes with different combinations in each layer (Figure 5), it seems possible to design membranes with selectivity close to the selectivity of Pebax-1657, but with much higher permeability. This could be used as a tool in the development of membranes desirable for their industrial post-combustion CO2 capture [3]. Resistance in the series model predicts a wide and realistic range of possible thickness combinations in the Pebax-1657/PDMS system (n values). The problem of the model in its simplified application, as performed here, is ignorance of the possible defects in the selective layer as well as porous support resistance, which indeed may become a significant factor as the gutter and selective layer become considerably thinner [5,31]. The purpose of further experiments is to check whether the resistance model predictions could serve as indicative for the planned membrane performance.
3.3. Cross Section Morphology of the Thin-Film Composite Membranes
To check the applicability of the resistance model predictions, we have fabricated the TFC membranes with different thicknesses of the PDMS layer. Cross-section scanning electron imaging was used to observe the morphology of the fabricated membranes and also to estimate the thickness of both the selective layer and gutter layer. As seen from Figure 6 we succeeded in fabricating the membranes with clearly defined morphology, and all layers were distinctively visible and well adhered to each other and the porous support. The unique combination of the materials and method used to fabricate the membrane enabled us to see the interface between the gutter layer and porous support. This was achieved exclusively thanks to the formation and crosslinking of the PDMS membrane on the solid support at first, and subsequent transfer onto the porous support. Such an approach enabled us to detect the clear interface between the PDMS layer and porous support in contrast to conventional depositions directly on the porous support [12,13].
Similarly, due to the different physical nature of the polymers, a clear interface is observed between the selective Pebax-1657 layer and PDMS. Therefore, acquired scanning electron microscopy (SEM) images can serve for both layers’ accurate thickness estimation. To obtain the distribution of thicknesses and standard deviation, the image analysis software (ImageJ 1.52d) was used to measure thickness in at least ten different places of the membrane. Table 2 summarizes the results of thicknesses for both layers. Subsequently, the thickness results were used to calculate model predictions for CO2 and N2 permeabilities, permeances, and CO2/N2 selectivity in fabricated membranes according to Equations (8) and (9).
Table 2.
Membrane # | Thickness of Pebax-1657 Layer, nm (ls ± Δls) 1 |
Thickness of PDMS Layer, nm (lg ± Δlg) 1 |
Ratio of Thicknesses, n = lg/ls | Model-Predicted CO2 Permeability, Barrer | Model-Predicted CO2 Permeance, GPU 2 | Model-Predicted Selectivity |
---|---|---|---|---|---|---|
M1 | 343 ± 58 | 307 ± 70 | 0.90 | 235 | 361 ± 71 | 62.3 |
M2 | 380 ± 29 | 428 ± 53 | 1.13 | 261 | 323 ± 33 | 61.8 |
M3 | 279 ± 55 | 626 ± 45 | 2.24 | 383 | 432 ± 47 | 59.9 |
M4 | 292 ± 23 | 2327 ± 164 | 7.97 | 883 | 337 ±24 | 51.8 |
M5 | 385 ± 15 | 10,775 ± 90 | 27.99 | 1805 | 162 ± 2 | 36.8 |
M6 | 320 ± 15 | 19,469 ± 165 | 60.84 | 2403 | 121 ± 1 | 27.1 |
1 Errors Δls and Δlg represent standard deviation of the ten independent measurements of thickness using SEM image analysis. Error for total thickness was calculated by addition of Δls and Δlg. 2 Errors of model predicted permeances were calculated assuming relative error of total thickness equal to relative error of calculated permeance.
3.4. Comparison of the Experimental Results with Resistance in Series Model Predictions
The results of expected CO2 permeability, permeance, and selectivity for the fabricated membranes are also given in Table 2. Considering the ratio of thicknesses (n) between the two layers, the values of permeability followed the expected trend, namely as the thickness of the PDMS layer became significantly larger compared to Pebax-1657 layer (n increases), permeability increased and approached the values closer to that of PDMS. At the same time, predicted selectivity behaved oppositely and decreased with the increase of the n value. Despite the significant differences of the total membrane thicknesses, permeances were not greatly different, as also shown in Table 2. It is expected there were implications from the two materials resistance to gas permeation. Namely, as Pebaxs relative resistance is ca. 30 times larger than PDMS resistance, the membrane M3 is expected to have the highest permeance due to the lowest thickness of Pebax-1657 layer. At the same time, it is expected to give a considerably higher selectivity value as the n value is small.
All membranes were subjected to the actual pure N2 and CO2 gas permeation measurements. Figure 7 contains a comparison of the experimentally acquired permeances, permeabilities, and selectivity with the resistance model predictions. As seen from Figure 7a,b, three thicker membranes (M4–M6) demonstrated a perfect match with the resistance model prediction for CO2 permeances with the experimental data. In contrast, thinner membranes (M1–M3) demonstrated substantially lower permeances compared to what was predicted by the model (86%, 28%, and 70% lower respectively). The same effect, but to smaller extent was observed for N2 permeance, namely 73%, 13% and 30% decrease of permeances in thinner membranes. This behavior is also reflected in the total permeability of the membranes (Figure 7c), namely experimental data do not overlap with modelled data even considering the uncertainty induced with thickness measurements (pink shading around model prediction). The CO2/N2 selectivity calculated as a ratio of pure gas permeabilities compared to values predicted by the resistance model is shown in Figure 7d. It is seen that selectivity for most of the membranes is lower than expected by the model, which could be explained by the certain amount of pinhole defects in the Pebax layer. However, the decrease of selectivity in TFC membranes is relatively small compared to the decrements of permeance in thin membranes. Summarizing the results, we can conclude that resistance models provide quite accurate predictions for the membrane separation parameters, however, only in cases where total membrane thickness is larger than 2 µm (in this particular case at least). Membranes with total thickness below 2 µm demonstrated significantly lower permeances of both gases while the selectivity of all TFC membranes was not significantly altered (deviation <20%).
4. Discussion
Fabrication of the TFC membranes for industrial gas separation is a mainstream approach pursued by many research groups and companies. However, to the best of our knowledge, there are not many works systematically investigating the performance of TFC membranes in relation to the thicknesses of the layers. The problem with such an investigation often lies in the difficulties to fabricate layers with precisely defined thicknesses, especially when the polymer solutions are coated directly on the porous supports. For example, Qiao et al. used to coat PDMS directly on the polyacrylonitrile porous support to fabricate the layers with thicknesses below 300 nm [12,13]. Although they reported thin gutter layer of PDMS, both selectivity and permeability are significantly lower compared to the bulk, meaning that some forms of defects, pin holes, or surface pore clogging may exist. Most often the decreased values are explained by the fact that during a direct coating on the porous support, polymer solution penetrates to some extent into the pores of the support. For such layers, permeability–thickness–permeance relations are not fulfilled, e.g., 445 nm PDMS layer having a permeance of 2000 GPU and selectivity ~8 [12], which is much lower than expected if calculated from bulk PDMS permeability ~7000 GPU and selectivity ~11.6.
The principle difference of our approach is in how the membrane is fabricated and assembled. Namely, the PDMS layer is formed and cured, being attached to the flat solid support and not coated directly on the porous support. This guarantees that the film has uniform thickness and probability of defect formation is significantly suppressed. The selective layer is deposited on the smooth and defect-free PDMS, enabling similarly well-defined morphology and uniform thickness. The expectations from such a membrane fabrication approach are that our system should be more easily predicted by the resistance model as both layers have well-defined thickness. However, as is shown in the results, we still observed a very significant deviation of experimental data from the model predictions in the case of thinner membranes. Therefore, there may be some other factors causing this mismatch. One phenomenon that may add additional resistance into the fabricated membranes is the interfacial layer between PDMS and Pebax-1657, formed due to the ozone treatment that was used to activate the PDMS surface and promote the adhesion of the selective layer. Many researchers have reported the increased gas barrier of PDMS after surface activation by oxygen plasma [8,23] or ozone treatment [32]. In our work, we have intentionally chosen the ozone treatment as a milder activation process compared to O2-plasma treatment. However, if the effect is significant enough it would be seen on all membrane performances, which contradicts experimental results, i.e., permeance and permeability decrease being observed only for thinner membranes. Therefore, this influence cannot explain the gas separation in all fabricated samples.
Another plausible reason for the worsened mass transport through the fabricated membranes is the interaction with the porous support. The influence of porous support was recently modeled by several research groups using computational fluid dynamics (CFD) [31,33]. In particular, is was demonstrated by Ramon et al. [31] that with considerable thinning of the layer attached to the porous support, gas transport happens exclusively in the place of the open pore. Wijmans et al. have extended the CFD model onto the TFC membranes consisting of a gutter layer additionally to a selective layer [33]. Their results showed that as the thickness of the gutter layer decreases, the permeance starts to demonstrate a declining behavior, however, according to the calculations, this happens only in the range of small, “impractical” thickness ranges (below 10 nm). Although the effects of such ultimately thin layers are interesting, our membranes are far from the range where porous support is expected to have a dramatic impact on transport. If the influence is indeed present, membranes used in this work could demonstrate slightly lower permeances than expected. In fact, what has been observed is much stronger decline that can be seen by comparing the performance of M4 and M3 membranes in particular, where the latter has both thinner Pebax and PDMS layers (279 vs. 292 nm and 626 vs. 2327 nm respectively) but at the same time also demonstrates less CO2 permeance (248 vs. 319 GPU). Based on these speculations, we believe that it is unlikely that porous support has a determinative impact on the result.
Finally, one more reason for the lower permeances in thinner membranes could be related to the thickness itself. Plenty of research papers have reported the phenomena of low permeability in thin films due to accelerated aging, mainly in glassy polymer membranes [5,34,35]. Both polymers used in this work are, however, rubbery polymers (PDMS Tg~−120 °C, Pebax MH1657 Tg~−50°C) and are not susceptible to physical aging. The decreased permeability due to thickness itself was reported for PDMS [36], and similar behavior was reported for certain grades of poly(butylene terephthalate)-b-poly(ethylene oxide), which is known as Polyactive® [7]. However, again the decrease that is reported is unlikely to be the single determining factor.
As a summary, we prepared the series of Pebax-1657/PDMS membranes with different thicknesses on a porous support and compared how the CO2/N2 separation performance corresponds with the predictions of resistance in series models. Surprisingly, lower permeances were observed in the thinner membranes compared with predictions made by the resistance model. We believe that deviation from the expected results can be caused by a cumulative effect from number of factors, such as ozone treatment influence, porous support influence, or thickness influence itself. Based on the current available data, it is difficult to conclude which factor is a primary contributor to the observed result. More detailed study is underway and will be reported elsewhere.
Author Contributions
Conceptualization, R.S. and S.F.; methodology, R.S.; formal analysis, R.S.; investigation, M.A. and R.S.; data curation, R.S.; writing—original draft preparation, R.S.; writing—review and editing, R.S. and S.F.; funding acquisition, S.F.
Funding
This work was supported by the World Premier International Research Center Initiative (WPI), sponsored by the Japanese Ministry of Education, Culture, Sports, Science and Technology. R. Selyanchyn acknowledges the Japan Society for Promotion of Science (JSPS) for a Grant-in-Aid for Research Start-up (no. 26889045).
Conflicts of Interest
The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.
References
- 1.Sholl D.S., Lively R.P. Seven chemical separations to change the world. Nature. 2016;532:435–437. doi: 10.1038/532435a. [DOI] [PubMed] [Google Scholar]
- 2.He X., Hägg M.B. Membranes for environmentally friendly energy processes. Membranes (Basel) 2012;2:706–726. doi: 10.3390/membranes2040706. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Merkel T.C., Lin H., Wei X., Baker R. Power plant post-combustion carbon dioxide capture: An opportunity for membranes. J. Membrane Sci. 2010;359:126–139. doi: 10.1016/j.memsci.2009.10.041. [DOI] [Google Scholar]
- 4.Robeson L.M. The upper bound revisited. J. Membrane Sci. 2008;320:390–400. doi: 10.1016/j.memsci.2008.04.030. [DOI] [Google Scholar]
- 5.Selyanchyn R., Fujikawa S. Membrane thinning for efficient CO2 capture. Sci. Technol. Adv. Mater. 2017;18:816–827. doi: 10.1080/14686996.2017.1386531. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Tiwari R.R., Smith Z.P., Lin H., Freeman B.D., Paul D.R. Gas permeation in thin films of “high free-volume” glassy perfluoropolymers: Part I. Physical aging. Polymer (United Kingdom) 2014;55:5788–5800. doi: 10.1016/j.polymer.2014.09.022. [DOI] [Google Scholar]
- 7.Yave W., Huth H., Car A., Schick C. Peculiarity of a CO2-philic block copolymer confined in thin films with constrained thickness: “a super membrane for CO2-capture”. Energy Environ. Sci. 2011;4:4656–4661. doi: 10.1039/c1ee02139g. [DOI] [Google Scholar]
- 8.Selyanchyn R., Staykov A., Fujikawa S. Incorporation of CO2 philic moieties into a TiO2 nanomembrane for preferential CO2 separation. RSC Adv. 2016;6:88664–88667. doi: 10.1039/C6RA18419G. [DOI] [Google Scholar]
- 9.Dai Z., Ansaloni L., Deng L. Recent advances in multi-layer composite polymeric membranes for CO2 separation: A review. Green Energy Environ. 2016;1:102–128. doi: 10.1016/j.gee.2016.08.001. [DOI] [Google Scholar]
- 10.Fam W., Mansouri J., Li H., Hou J., Chen V. Gelled Graphene Oxide-Ionic Liquid Composite Membranes with Enriched Ionic Liquid Surfaces for Improved CO2 Separation. ACS Appl. Mater. Interfaces. 2018;10:7389–7400. doi: 10.1021/acsami.7b18988. [DOI] [PubMed] [Google Scholar]
- 11.Sutrisna P.D., Hou J., Zulkifli M.Y., Li H., Zhang Y., Liang W., D’Alessandro D.M., Chen V. Surface functionalized UiO-66/Pebax-based ultrathin composite hollow fiber gas separation membranes. J. Mater. Chem. A. 2018;6:918–931. doi: 10.1039/C7TA07512J. [DOI] [Google Scholar]
- 12.Kim J., Fu Q., Scofield J.M.P., Kentish S.E., Qiao G.G. Ultra-thin film composite mixed matrix membranes incorporating iron(III)–dopamine nanoparticles for CO2 separation. Nanoscale. 2016;8:8312–8323. doi: 10.1039/C5NR08840B. [DOI] [PubMed] [Google Scholar]
- 13.Kim J., Fu Q., Xie K., Scofield J.M.P., Kentish S.E., Qiao G.G. CO2 separation using surface-functionalized SiO2 nanoparticles incorporated ultra-thin film composite mixed matrix membranes for post-combustion carbon capture. J. Membrane Sci. 2016;515:54–62. doi: 10.1016/j.memsci.2016.05.029. [DOI] [Google Scholar]
- 14.Chen H.Z., Thong Z., Li P., Chung T.S. High performance composite hollow fiber membranes for CO2/H2 and CO2/N2 separation. Int. J. Hydrogen Energy. 2014;39:5043–5053. doi: 10.1016/j.ijhydene.2014.01.047. [DOI] [Google Scholar]
- 15.Bondar V.I., Freeman B.D., Pinnau I. Gas sorption and characterization of poly(ether-b-amide) segmented block copolymers. J. Polym. Sci. Part B Polym. Phys. 1999;37:2463–2475. doi: 10.1002/(SICI)1099-0488(19990901)37:17<2463::AID-POLB18>3.0.CO;2-H. [DOI] [Google Scholar]
- 16.Henis J.M.S., Tripodi M.K. Composite hollow fiber membranes for gas separation: The resistance model approach. J. Membrane Sci. 1981;8:233–246. doi: 10.1016/S0376-7388(00)82312-1. [DOI] [Google Scholar]
- 17.Mersha A., Selyanchyn R., Fujikawa S. Preparation of large, ultra-flexible and free-standing nanomembranes of metal oxide–polymer composite and their gas permeation properties. Clean Energy. 2017;1:80–89. doi: 10.1093/ce/zkx006. [DOI] [Google Scholar]
- 18.Fujikawa S., Ariyoshi M., Shigyo E., Fukakusa C., Selyanchyn R., Kunitake T. Preferential CO2 separation over nitrogen by a free-standing and nanometer-thick membrane. Energy Procedia. 2017;114:608–612. doi: 10.1016/j.egypro.2017.03.1907. [DOI] [Google Scholar]
- 19.Bayer T., Selyanchyn R., Fujikawa S., Sasaki K., Lyth S.M. Spray-painted graphene oxide membrane fuel cells. J. Membrane Sci. 2017;541:347–357. doi: 10.1016/j.memsci.2017.07.012. [DOI] [Google Scholar]
- 20.Berean K., Ou J.Z., Nour M., Latham K., McSweeney C., Paull D., Halim A., Kentish S., Doherty C.M., Hill A.J., et al. The effect of crosslinking temperature on the permeability of PDMS membranes: Evidence of extraordinary CO2 and CH4 gas permeation. Sep. Purif. Technol. 2014;122:96–104. doi: 10.1016/j.seppur.2013.11.006. [DOI] [Google Scholar]
- 21.Allen S.M., Fujii M., Stannett V., Hopfenberg H.B., Williams J.L. The barrier properties of polyacrylonitrile. J. Membrane Sci. 1977;2:153–163. doi: 10.1016/S0376-7388(00)83241-X. [DOI] [Google Scholar]
- 22.Merkel T.C., Bondar V.I., Nagai K., Freeman B.D., Pinnau I. Gas sorption, diffusion, and permeation in poly (dimethylsiloxane) J. Polym. Sci. Part B Polym. Phys. 2000;38:415–434. doi: 10.1002/(SICI)1099-0488(20000201)38:3<415::AID-POLB8>3.0.CO;2-Z. [DOI] [Google Scholar]
- 23.Houston K.S., Weinkauf D.H., Stewart F.F. Gas transport characteristics of plasma treated poly(dimethylsiloxane) and polyphosphazene membrane materials. J. Membrane Sci. 2002;205:103–112. doi: 10.1016/S0376-7388(02)00068-6. [DOI] [Google Scholar]
- 24.De Bo I., Van Langenhove H., Pruuost P., De Neve J., Pieters J., Vankelecom I.F.J., Dick E. Investigation of the permeability and selectivity of gases and volatile organic compounds for polydimethylsiloxane membranes. J. Membrane Sci. 2003;215:303–319. doi: 10.1016/S0376-7388(03)00024-3. [DOI] [Google Scholar]
- 25.Surya Murali R., Sridhar S., Sankarshana T., Ravikumar Y.V.L. Gas permeation behavior of Pebax-1657 nanocomposite membrane incorporated with multiwalled carbon nanotubes. Ind. Eng. Chem. Res. 2010;49:6530–6538. doi: 10.1021/ie9016495. [DOI] [Google Scholar]
- 26.Li Y., Chung T.S. Molecular-level mixed matrix membranes comprising Pebax® and POSS for hydrogen purification via preferential CO2 removal. Int. J. Hydrogen Energy. 2010;35:10560–10568. doi: 10.1016/j.ijhydene.2010.07.124. [DOI] [Google Scholar]
- 27.Bernardo P., Jansen J.C., Bazzarelli F., Tasselli F., Fuoco A., Friess K., Izák P., Jarmarová V., Kačírková M., Clarizia G. Gas transport properties of Pebax®/room temperature ionic liquid gel membranes. Sep. Purif. Technol. 2012;97:73–82. doi: 10.1016/j.seppur.2012.02.041. [DOI] [Google Scholar]
- 28.Rahman M.M., Filiz V., Shishatskiy S., Abetz C., Neumann S., Bolmer S., Khan M.M., Abetz V. PEBAX® with PEG functionalized POSS as nanocomposite membranes for CO2 separation. J. Membrane Sci. 2013;437:286–297. doi: 10.1016/j.memsci.2013.03.001. [DOI] [Google Scholar]
- 29.Yu B., Cong H., Li Z., Tang J., Zhao X.S. Pebax-1657 nanocomposite membranes incorporated with nanoparticles/ colloids/carbon nanotubes for CO2/N2 and CO2/H2 separation. J. Appl. Polym. Sci. 2013;130:2867–2876. doi: 10.1002/app.39500. [DOI] [Google Scholar]
- 30.Zhao D., Ren J., Li H., Li X., Deng M. Gas separation properties of poly(amide-6-b-ethylene oxide)/amino modified multi-walled carbon nanotubes mixed matrix membranes. J. Membrane Sci. 2014;467:41–47. doi: 10.1016/j.memsci.2014.05.009. [DOI] [Google Scholar]
- 31.Ramon G.Z., Wong M.C.Y., Hoek E.M. V Transport through composite membrane, Part 1: Is there an optimal support membrane? J. Membrane Sci. 2012;415–416:298–305. doi: 10.1016/j.memsci.2012.05.013. [DOI] [Google Scholar]
- 32.Fu Y.J., Qui H.Z., Liao K.S., Lue S.J., Hu C.C., Lee K.R., Lai J.Y. Effect of UV-Ozone treatment on poly(dimethylsiloxane) membranes: Surface characterization and gas separation performance. Langmuir. 2010;26:4392–4399. doi: 10.1021/la903445x. [DOI] [PubMed] [Google Scholar]
- 33.Wijmans J.G., Hao P. Influence of the porous support on diffusion in composite membranes. J. Membrane Sci. 2015;494:78–85. doi: 10.1016/j.memsci.2015.07.047. [DOI] [Google Scholar]
- 34.Huang Y., Paul D.R. Physical aging of thin glassy polymer films monitored by gas permeability. Polymer (Guildf) 2004;45:8377–8393. doi: 10.1016/j.polymer.2004.10.019. [DOI] [Google Scholar]
- 35.Müller N., Handge U.A., Abetz V. Physical aging and lifetime prediction of polymer membranes for gas separation processes. J. Membrane Sci. 2016;516:33–46. doi: 10.1016/j.memsci.2016.05.055. [DOI] [Google Scholar]
- 36.Firpo G., Angeli E., Repetto L., Valbusa U. Permeability thickness dependence of polydimethylsiloxane (PDMS) membranes. J. Membrane Sci. 2015;481:1–8. doi: 10.1016/j.memsci.2014.12.043. [DOI] [Google Scholar]