Skip to main content
EJNMMI Research logoLink to EJNMMI Research
. 2019 Jan 7;9:3. doi: 10.1186/s13550-018-0471-8

A phase 1, first-in-human study of 18F-GP1 positron emission tomography for imaging acute arterial thrombosis

Sun Young Chae 1,#, Tae-Won Kwon 2,#, Soyoung Jin 3,#, Sun U Kwon 4, Changhwan Sung 1, Seung Jun Oh 1, Sang Ju Lee 1, Jungsu S Oh 1, Youngjin Han 2, Yong-Pil Cho 2, Narae Lee 5, Ji Young Kim 6, Norman Koglin 7, Mathias Berndt 7, Andrew W Stephens 7, Dae Hyuk Moon 1,
PMCID: PMC6323046  PMID: 30617563

Abstract

Background

18F-GP1 is a novel positron emission tomography (PET) tracer that targets glycoprotein IIb/IIIa receptors on activated platelets. The study objective was to explore the feasibility of directly imaging acute arterial thrombosis (AAT) with 18F-GP1 PET/computed tomography (PET/CT) and to quantitatively assess 18F-GP1 uptake. Safety, biodistribution, pharmacokinetics and metabolism were also evaluated.

Methods

Adult patients who had signs or symptoms of AAT or had recently undergone arterial intervention or surgery within 14 days prior to 18F-GP1 PET/CT were eligible for inclusion. The AAT focus was demonstrated by conventional imaging within the 5 days prior to 18F-GP1 administration. Whole-body dynamic 18F-GP1 PET/CT images were acquired for up to 140 min after injection of 250 MBq of 18F-GP1. Venous plasma samples were analysed to determine 18F-GP1 clearance and metabolite formation.

Results

Among the ten eligible patients assessed, underlying diseases were abdominal aortic aneurysm with endovascular repair (n = 6), bypass surgery and stent placement (n = 1), endarterectomy (n = 1), arterial dissection (n = 1) and acute cerebral infarction (n = 1). 18F-GP1 administration and PET/CT procedures were well tolerated, with no drug-related adverse events. All patients showed high initial 18F-GP1 uptake in the spleen, kidney and blood pool, followed by rapid clearance. Unmetabolised plasma 18F-GP1 levels peaked at 4 min post-injection and decreased over time until 120 min. The overall image quality was sufficient for diagnosis in all patients and AAT foci were detected in all participants. The 18F-GP1 uptake in AAT foci remained constant from 7 min after injection and began to separate from the blood pool after 20 min. The median standardised uptake value of AAT was 5.0 (range 2.4–7.9) at 120 min post-injection. The median ratio of standardised uptake value of AAT foci to the mean blood pool activity was 3.4 (range 2.0–6.3) at 120 min.

Conclusions

18F-GP1 is a safe and promising novel PET tracer for imaging AAT with a favourable biodistribution and pharmacokinetic profile.

Trial registration

ClinicalTrials.gov identifier: NCT02864810, Registered August 3, 2016.

Electronic supplementary material

The online version of this article (10.1186/s13550-018-0471-8) contains supplementary material, which is available to authorized users.

Keywords: Arterial thrombosis, Positron emission tomography, 18F-GP1, Platelet activation, Glycoprotein IIb/IIIa receptor

Background

Acute arterial thrombosis (AAT) is the proximate cause of myocardial infarction and stroke [1], collectively the leading cause of death in developed and developing countries [2, 3]. Unfortunately, prediction of adverse events from atherosclerotic plaque-related thrombus formation by comprehensive scores [4, 5] is not sufficient for individual risk assessment [6, 7]. AAT is typically triggered by the rupture of an atherosclerotic plaque and recent efforts have focused on advanced imaging methods to detect vulnerable atherosclerotic plaques that are particularly susceptible to disruption [8], thereby identifying patients who would benefit most from intensive preventive efforts [6]. However, to date, this has not translated into improved risk prediction compared with traditional approaches [912] and the need remains for a better understanding of imaging information and systemic risk factors for comprehensive risk assessment [7, 13, 14].

Currently, AAT is diagnosed using magnetic resonance imaging, computed tomography (CT) and angiography to visualise the obstructed blood flow, to characterise AAT after atherosclerotic plaque rupturing and to identify patients who may benefit from pharmacologic or invasive management [15, 16]. However, these approaches do not directly visualise the active pathology of AAT and identification of the culprit lesion is not always possible [1721]. Direct imaging of AAT may increase the accuracy of detection of AAT foci associated with atherosclerotic rupture and enable clinicians to evaluate and monitor personalised pharmacologic or invasive management [22]. It may also be possible to predict adverse events resulting from plaque rupture by detecting plaque haemorrhage that has been associated with poor outcomes [12, 23]. To date, most AAT imaging has been studied in animals and is yet to translate into the clinic [22].

When an atherosclerotic plaque ruptures, platelets are rapidly recruited to the site and thrombi formed in arteries are rich in platelets [1]. 18F-GP1 is a new fluorine-18 labelled elarofiban derivative that specifically binds with high affinity to glycoprotein IIb/IIIa receptors on the surface of activated platelets [24]. In vitro assays have shown that 18F-GP1 binds to thrombi with a high clot-to-blood ratio; the binding affinity was not significantly affected by aspirin and heparin, and 18F-GP1 detected small AAT foci in thrombotic depositions on damaged arteries with rapid blood clearance in a monkey thrombus model [24]. More recently, 18F-GP1 has been successfully used in the imaging of lesions in patients with symptoms of acute deep vein thrombosis or pulmonary embolism [25].

The objectives of this study were to explore the feasibility of detecting AAT foci with 18F-GP1 positron emission tomography/CT (PET/CT) in patients with AAT and to quantitatively assess 18F-GP1 uptake. In addition, safety, biodistribution, pharmacokinetics and metabolism were assessed. To obtain the first clinical proof of concept for the detection of arterial thrombosis, patients who had undergone arterial intervention or surgery, such as endovascular abdominal aortic aneurysm repair (EVAR), were evaluated, as the endovascular stent grafts are thrombogenic and promote fibrin deposition and platelet aggregation [2628]. These patients may, therefore, represent a clinical model of early arterial thrombosis [28]. In parallel, patients with AAT were examined with 18F-GP1 PET/CT to investigate AAT in clinically relevant settings.

Methods

Study design

A prospective, open-label, non-randomised, single-dose exploratory study was conducted to assess the safety, pharmacokinetics, biodistribution and diagnostic performance of 18F-GP1 PET/CT imaging in subjects with AAT or those who had undergone arterial intervention or surgery, such as EVAR. This study was conducted in parallel to a study of patients with venous thrombi that are rich in fibrin and red blood cells [25]. The study protocol was approved by the Ministry of Food and Drug Safety of Korea and the Institutional Review Board of the Asan Medical Center (Seoul, Republic of Korea). The study was conducted in accordance with the Declaration of Helsinki and institutional guidelines. All subjects provided written informed consent before participating in the study. This trial was registered at http://www.clinicaltrials.gov as NCT02864810.

The study was designed to obtain clinical proof of concept. The number of patients examined should be as low as possible for ethical reasons, but sufficiently high to avoid inconclusive results. It was, therefore, planned to enrol ten patients with AAT, plus replacements for drop-outs.

Patients

Patients eligible for inclusion were adults (≥ 19 years) who had signs or symptoms of AAT or recent arterial intervention or surgery within 14 days prior to 18F-GP1 PET/CT study, thromboembolic focus demonstrated by standard imaging within 5 days before administration of 18F-GP1, Eastern Cooperative Oncology Group performance status of 0–2 and adequate function of major organs. Patients were excluded for the following reasons: pretreatment with glycoprotein IIb/IIIa inhibitors within 15 days before the study; chemotherapy before or within 24 h after administration of 18F-GP1; pregnancy; a severe, uncontrolled and/or unstable medical disease other than cancer; or any other condition or personal circumstances that might make collection of complete data difficult or impossible. Potential patients for inclusion in this study were identified at the inpatient and outpatient clinics of the Asan Medical Center (Seoul, Republic of Korea).

Radiopharmaceutical preparation

18F-GP1 was synthesised by nucleophilic radiofluorination starting from the protected tosylate precursor using a non-cassette type chemistry module (TRACERlab FXFN, GE Healthcare), as previously described [24]. Each batch of 18F-GP1 met the criteria listed in the specification for identity, purity, radioactive concentration of 18F-GP1, specific activity, pH, bacterial endotoxin level and sterility. The final product was formulated as a sterile solution for intravenous injection.

Procedures for 18F-GP1 PET/CT and pharmacokinetics and metabolite analysis of 18F-GP1

Patients were encouraged to drink a sufficient amount of water prior to 18F-GP1 PET/CT. No food restrictions were required. A radioactivity of 250 ± 25 MBq of 18F-GP1 at a total mass dose of ≤ 10 μg was administered as a slow intravenous bolus injection for up to 60 s. 18F-GP1 PET/CT images were acquired using a PET/CT scanner (Discovery PET/CT 690 or Discovery PET/CT 710; GE Healthcare), as previously described [25]. Serial whole-body 18F-GP1 PET/CT acquisition covering vertex to toe was conducted in three scanning sessions. The first time window ranged from 0 (immediately after radiotracer injection)–35 min, the second session from 60 to 80 min and the third session from 120 to 140 min. For attenuation correction of the PET scan, a low dose CT (100 kV, 20 mAs) was performed for each imaging session. Patients were asked to void their bladder before and after each imaging session.

To determine the clearance of 18F-GP1 and metabolite formation, venous samples were obtained at 1, 3, 10, 30, 60 and 120 min after 18F-GP1 injection. Radioactivity in the plasma and whole blood samples was measured using a well gamma counter (Cobra II Auto Gamma, Canberra Packard) and expressed as a percentage of the total injected 18F-GP1 activity per millilitre (%IA/mL). The percent fraction of the authentic non-metabolised 18F-GP1 in the blood was quantified by thin-layer chromatography using iTLC-SG strips (Agilent Technologies), as previously described [29]. The area under the time activity curve, peak plasma level and time taken to reach the peak level of non-metabolised 18F-GP1 were calculated. Urine was collected for measurement of urinary radioactivity from 18F-GP1 injection to 3 h post-injection.

Safety assessments included laboratory test results (Additional file 1: Table S1), vital signs, electrocardiograms and physical examinations before and 3 h after intravenous administration of 18F-GP1 and again at 24 h. Adverse events were recorded from the time of patient enrollment until the events were resolved, or up to a maximum of 28 days after the follow-up visit. Assessment of baseline plasma fibrinogen levels was measured based on the time for fibrin clot formation, as previously described [30], using Dade Thrombin Reagent (Siemens Healthcare Diagnostics Products) and an automated coagulation analyser Sysmex® CS-5100 system (Sysmex).

Assessment of 18F-GP1 PET/CT

18F-GP1 PET/CT images were analysed by the consensus of two nuclear medicine physicians, who were provided with information on standard imaging, clinical and laboratory findings. The readers reviewed all images to determine whether overall image quality was adequate for interpretation. For dynamic assessment of 18F-GP1 biodistribution, volumes of interest (VOIs) were drawn over normal organs on dynamic fused PET/CT images. In addition, spherical VOIs with a diameter of 12 mm were centred on the maximum 18F-GP1 uptake of AAT lesions for the assessment of dynamic biodistribution in AAT lesions. A VOI was placed on the descending thoracic aorta to obtain blood pool information, as previously recommended [31]. Standardised uptake values (SUVs) were normalised to the injected activity and the patients’ body weight, and were defined as follows: SUV (g/mL) = (activity (Bq/mL) / injected activity (Bq)) × body weight (g). Mean standardised uptake values (SUVmean) of the VOI were obtained on each time frame to generate a time–activity profile of the 18F-GP1 uptake.

Analysis of AAT included 18F-GP1 uptake in arteries of patients who underwent arterial intervention or surgery or showed filling defects on standard imaging modalities. When lesions showed increased uptake in relation to background blood pool activity, they were regarded as positive thromboembolic foci. Maximum SUV (SUVmax) and the ratio of the SUVmax to the SUVmean of blood pool were measured of each AAT focus.

The ability of 18F-GP1 PET/CT for detecting AAT was assessed in terms of patient-based detection. Other lesions detected by 18F-GP1 PET/CT were also analysed.

Statistical analysis

Data are expressed as median and range. A p value of < 0.05 was considered statistically significant. Comparison was conducted using the Wilcoxon rank-sum and signed-rank test, and Spearman’s rank correlation coefficient. All statistical tests were performed on the IBM SPSS Statistics for Windows (version 21, IBM Company).

Results

Patient characteristics and 18F-GP1 PET/CT procedures

Eleven patients were enrolled in the study and received 18F-GP1 between August 2016 and August 2017. One patient withdrew consent after receiving 18F-GP1 injection but before PET/CT acquisition; therefore, ten patients were included in the study. All were male with a median age of 72.5 years (range 44–82). The patient characteristics are listed in Table 1. The majority of patients (n = 6) underwent EVAR for an abdominal aortic aneurysm. The diagnosis of AAT in the remaining four patients was confirmed by CT (n = 3) or magnetic resonance imaging (n = 1). The median time interval between onset of symptoms or surgery and 18F-GP1 PET/CT was 6 days (range 3–7). The median administered activity was 246.1 MBq (range 240.5–251.6) and the median administered mass dose was 1.7 μg (range 0.1–3.8). Nine patients had no protocol deviation and were included in the pharmacokinetic analysis.

Table 1.

Characteristics of the patients with acute arterial thrombosis (n = 10)

Characteristics Value (range or %)
Median age, years 72.5 (44–82)
Male 10 (100)
Non-Hispanic/Latino and Asian (Korean) 10 (100)
Median body mass index, kg/m2 23.6 (18.9–28.4)
Underlying disease associated with arterial thrombosis
 Abdominal aortic aneurysm with EVAR 6 (60)
 Bypass surgery and stent placement for peripheral atherosclerosis 1 (10)
 Endarterectomy and angioplasty for peripheral atherosclerosis 1 (10)
 Arterial dissection 1 (10)
 Acute cerebral infarction 1 (10)
Risk factors for cardiovascular disease
 Hypertension 7 (70)
 Smoking 10 (100)
 Diabetes 3 (30)
 Obesity 0 (0)
 Hyperlipidemia 2 (20)
Medication prior to 18F-GP1 PET/CT
 Prior anticoagulant therapy 5 (50)
 Prior antiplatelet therapy 6 (60)

EVAR endovascular abdominal aortic aneurysm repair, PET positron emission tomography, CT computed tomography

Safety

18F-GP1 administration and PET/CT procedures were well tolerated in all patients. There were treatment-emergent adverse events of mild severity in three patients, which included symptoms or diagnostic observations due to one acute coronary syndrome, one hepatobiliary disease and one rash. The patient with acute coronary syndrome was treated with percutaneous coronary intervention 2 days before the 18F-GP1 injection. At the time of 18F-GP1 administration, most symptoms associated with acute coronary syndrome were resolved, but symptoms with mild intensity were reported. The patient with hepatobiliary disease had abnormal liver function test 10 h before the 18F-GP1 administration, which was not found 5 days before the enrollment to this study. The patients showed elevated liver enzymes 2 h after the 18F-GP1 administration. Asymptomatic skin rash was developed 6 h after 18F-GP1 injection in one patient. Based on chronology of the adverse events and clinical manifestations, the investigators judged that none of them were related to 18F-GP1, or the study procedure.

Biodistribution and pharmacokinetics of 18F-GP1

All patients showed high initial 18F-GP1 uptake in the spleen, kidney, blood pool and liver, followed by hepatobiliary and urinary clearance (Fig. 1, Fig. 2a and Additional file 1: Table S2). The median SUVmean values in the spleen, kidney, blood pool and liver were < 1.5 at 120 min after injection. No elevated 18F-GP1 uptake was observed in the brain, lung, muscle or bones.

Fig. 1.

Fig. 1

18F-GP1 biodistribution over time. The 18F-GP1 uptake in the kidney, spleen and blood gradually decreases over time. The 18F-GP1 uptake in AAT lesions remains constant from 7 min after injection. The median values of ten patients are shown

Fig. 2.

Fig. 2

18F-GP1 PET/CT and CT images of a 73-year-old man who had undergone endovascular abdominal aortic aneurysm repair surgery. Anterior maximum intensity projections of 18F-GP1 PET/CT show positive 18F-GP1 accumulation in the inner surface of abdominal aortic graft (arrow) and the lower portion of the left kidney (dotted arrow), which are increasingly distinct in later images as background 18F-GP1 activity clears over time via urinary and hepatobiliary excretion (a). Transaxial CT and PET images show increased 18F-GP1 uptake in the inner surface of the left iliac artery graft (b, arrows), but no 18F-GP1 uptake in the chronic intraluminal thrombus in the right iliac aneurysmal sac (b, arrow heads). Additional positive 18F-GP1 uptake is observed in the non-enhancing renal ischaemic area involving the lower portion of the left kidney (c, dotted arrows)

Radiolabeled metabolites were detected in only one patient with low-grade fever (38.1 °C), in whom the metabolite fraction was 12.4% at 3 min and 37.6% at 60 min after injection. The unmetabolised 18F-GP1 in plasma peaked at 0.0165 %IA/mL (range 0.0069–0.0253) 4 min after injection (range 2–10) and started to decrease over time until 120 min (0.0036 %IA/mL, range 0.0008–0.0049). The median peak radioactivity in whole blood was 0.0112 %IA/mL (range 0.0048–0.0182). The median area under the curve of unmetabolised 18F-GP1 in plasma was 1.402 %IA/mL (range 0.582–1.645). The median total radioactivity in urine was 76.2% of injected activity with a range of 35.9–81.5.

18F-GP1 uptake in AAT

The 18F-GP1 uptake in arterial thrombi remained constant from 7 min after injection (Figs. 1 and 2a, Additional file 1: Table S2). The median SUVmax of AAT foci was 5.3 (range 2.8–7.3) at 60 min and 5.0 (range 2.4–7.9) at 120 min (p = 0.29). There was no significant difference in the SUVmax of the target lesions between patients who underwent EVAR and the other four subjects who had AAT (p > 0.10). SUVmax was not associated with prior anticoagulation or antiplatelet treatment (p > 0.10). As a result of clearance from the blood pool, the ratio of SUVmax of AAT foci to blood pool increased over time to 120 min: 2.6 (range 1.5–3.9) at 60 min and 3.4 (range 2.0–6.3) at 120 min (p = 0.005). Elevated plasma fibrinogen was found in all ten patients (4.5 mg/mL; range 4.2–5.9). The SUVmax of AAT foci at 60 and 120 min showed no significant correlation with the fibrinogen level (p > 0.10).

The image quality was adequate for interpretation in all patients. 18F-GP1 PET/CT distinguished between blood pool activity and AAT foci from 60 min after injection (Fig. 2a). 18F-GP1 PET/CT detected AAT in all ten patients, which include AAT foci in the abdominal aorta (n = 7, Fig. 2b), internal carotid artery (n = 1, Fig. 3a), superficial femoral artery (n = 1) and popliteal artery (n = 1, Fig. 4a–c). In patients with EVAR, positive 18F-GP1 uptake was seen on the endograft’s surface, but not in the intramural thrombus or blood trapped in the aneurysm sac. In addition, in four patients, 18F-GP1 PET/CT showed seven arterial lesions with increased uptake in the proximal internal carotid (Fig. 3b), middle cerebral, external iliac (Fig. 4d, e), common femoral (Fig. 4f, g) and superficial femoral arteries, as well as the femoral popliteal bypass graft (Additional file 1: Figure S1), which corresponded to 18F-GP1 uptake associated with atherosclerosis (n = 2), thromboembolic occlusion (n = 1), arterial dissection after surgery (n = 1), endarterectomy (n = 1), stent implementation (n = 1) and bypass graft (n = 1). Increased 18F-GP1 uptake was also seen in the cerebral and renal ischaemic area (Fig. 2c) and popliteal vein.

Fig. 3.

Fig. 3

18F-GP1 PET/CT and magnetic resonance images of a 61-year-old man with acute cerebral infarction in the right middle cerebral artery territory and basal ganglia. Transaxial images of 18F-GP1 PET/CT at 60 min after injection show increased uptake in the petrous part of the right internal carotid artery (a, arrows) and right proximal internal carotid artery (b, dotted arrows). Magnetic resonance images reveal filling defects in right internal carotid artery (a, b). A smooth echogenic plaque was seen from the bilateral carotid bulbs to the proximal internal carotid arteries on transcranial Doppler (large-artery atherosclerosis subtype)

Fig. 4.

Fig. 4

18F-GP1 PET/CT images of a 63-year-old man with right common femoral artery endarterectomy and right popliteal artery angioplasty. Anterior maximum intensity projection and transaxial images of 18F-GP1 PET/CT at 120 min after injection show a focal increased uptake in the right popliteal artery (a, b; arrows), which corresponds to the AAT lesion after angioplasty (c). Additional positive 18F-GP1 uptake is observed in the dissected right distal external iliac artery (d, e; dotted arrows) and right common femoral artery (a, f; arrow heads) where endarterectomy was performed due to occlusion 3 days before 18F-GP1 PET/CT (g, arrow head)

Discussion

The data presented here represent the first human experience of 18F-GP1 in patients with AAT. As previously observed in patients with acute deep vein thrombosis or pulmonary embolism, 18F-GP1 showed a favourable biodistribution and pharmacokinetic and safety profiles. Rapid clearance from the blood pool and retention of 18F-GP1 uptake in delayed images allowed the diagnosis of AAT in all patients.

The symptoms and severity of AAT depends on the degree of arterial stenosis. For ethical reasons, patients who were unstable due to flow-limiting AAT were excluded and, therefore, only four patients with AAT were enrolled. The majority of patients (n = 6) had undergone EVAR for the treatment of an abdominal aortic aneurysm. Patients with EVAR may represent a real-life situation that involves platelet activation and aggregation during early thrombus formation, and were therefore considered suitable candidates for assessing the ability of 18F-GP1 to detect small thrombus formation.

The biodistribution and pharmacokinetics results of 18F-GP1 in patients with AAT showed clearance from major organs of the body, whereas 18F-GP1 uptake in AAT foci remained stable after 7 min. Thrombus-to-blood pool ratio increased over time up to 120 min due to continuous blood pool clearance. Our biodistribution and pharmacokinetic data are therefore consistent with those seen in a parallel study of patients with venous thromboembolism [25] and in animal models [24]. The high-quality imaging characteristics of 18F-GP1 may be due to its high specificity and affinity toward activated glycoprotein IIb/IIIa receptors on platelets [24]. The biodistribution data indicate that equilibrium was not achieved over 120 min and the specific retention of 18F-GP1 may be considered irreversible on the imaging timescale. Although we detected metabolites of 18F-GP1 in one patient, image quality and the ability of 18F-GP1 PET/CT to detect AAT was not affected.

AAT foci were detected in all patients using 18F-GP1 PET/CT up to 7 days after symptom onset regardless of prior anticoagulant or antiplatelet treatment. In patients with EVAR, we found the surface deposition of 18F-GP1 uptake in the endografts where thrombogenesis may persist for approximately 6 months after implantation [32]. Intraprosthetic thrombus deposition is commonly observed during follow-up for EVAR; however, it may not be associated with thromboembolic events over time [33]. Although 18F-GP1 uptake in the endografts may be related to mural thrombus formation, it is unlikely to be clinically relevant. No 18F-GP1 uptake was found in intramural thrombi or trapped blood after EVAR. It is believed that blood trapped in the aneurysmal sac during EVAR will coagulate and develop into a thrombus [34]. Therefore, the lack of 18F-GP1 uptake observed in the intramural thrombus or trapped blood could be because the aneurysm was concealed after EVAR.

Glycoprotein IIb/IIIa inhibitors and elevated fibrinogen can inhibit 18F-GP1 binding to activated platelets, which may limit the diagnostic use of 18F-GP1. However, currently, the use of glycoprotein IIb/IIIa inhibitors has become limited owing to high rates of bleeding complications and the development of alternative classes of antiplatelet drugs with improved safety features [35]. In addition, elevated fibrinogen did not affect 18F-GP1 uptake in AAT foci in this study. Therefore, it is not expected that this could compromise clinical use of 18F-GP1 for imaging AAT.

In this study, unexpected 18F-GP1 uptake was detected that may be associated with thrombotic events. One ischaemic stroke patient showed focal 18F-GP1 uptake in the stenotic internal carotid artery where plaque rupture may have occurred. In another patient, a focal 18F-GP1 uptake may be consistent with stent thrombosis. These findings suggest possible future applications for 18F-GP1 in imaging of atherosclerotic plaque rupture and delayed stent thrombosis. 18F-GP1 uptake in cerebral and renal ischaemic areas is also an area of interest and further research is required to investigate whether these findings are indicative of post-ischaemic platelet activation.

Our study has several limitations. The high detection rate should be interpreted with caution due to the small number of patients. Furthermore, the inclusion criteria and study design may not allow us to evaluate the clinical relevance of positive 18F-GP1 in patients. No follow-up data are available to discriminate between true or false-positive 18F-GP1 uptake. The efficacy and utility of this approach should be further evaluated in additional clinical trials including patients with atherosclerotic cardiovascular disease.

Conclusions

18F-GP1 is a novel and promising PET tracer for imaging AAT with a favourable biodistribution, pharmacokinetic and safety profile. Despite the limited patient numbers, this first-in-human trial has demonstrated that 18F-GP1 was able to locate activated platelet deposition in all study subjects. Small lesions in both the carotid and peripheral vascular distributions were visualised, suggesting the possibility of diverse indications and supporting the concept that a single whole-body image could reveal multiple, perhaps unexpected, lesions. Further evaluation will be required to demonstrate the clinical utility of imaging AAT with 18F-GP1 PET/CT in risk stratification and the potential to select patients who would benefit from greater preventive or therapeutic measures, and monitoring personalised pharmacologic or invasive management.

Additional file

Additional file 1: (499.6KB, pdf)

Table S1. Clinical laboratory parameters for safety assessment. Table S2. 18F-GP1 uptake over time. Figure S1. 18F-GP1 PET/CT images of a 76-year-old man with bypass surgery and stent placement. (PDF 499 kb)

Acknowledgements

The authors thank Yu Jin Lee and Nu-Ree Park from the Laboratory of Clinical Research Center, Asan Institute for Life Sciences, and Soonsang Yoon, Hyunsoo Ko, and Woo Young Chung from Nuclear Medicine, Asan Medical Center for their excellent technical assistance in conducting this study.

Funding

This study was sponsored by Asan Foundation (Seoul, Republic of Korea) and financially supported by the Asan Institute for Life Sciences, Asan Medical Center (Seoul, Republic of Korea), Life Molecular Imaging GmbH (formerly Piramal Imaging GmbH, Berlin, Germany), the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHDI) funded by the Ministry of Health & Welfare, Republic of Korea (grant number: HR18C2383) and the Radiation Technology Development Program of the National Research Foundation funded by the Korea Ministry of Science, ICT & Future Planning, Republic of Korea (grant number: NRF-2016M2A2A7A03913219).

Availability of data and materials

All data generated or analysed during this study are included in this published article (and its supplementary information files).

Abbreviations

AAT

Acute arterial thrombosis

CT

Computed tomography

EVAR

Endovascular abdominal aortic aneurysm repair

PET

Positron emission tomography

SUV

Standardised uptake value

SUVmax

Maximum standardised uptake value

SUVmean

Mean standardised uptake value

Authors’ contribution

All authors have reviewed and approved the final document. The specific contributions of each author are as follows: Conception and design, TWK, SJ, AWS and DHM; Data acquisition, SYC, TWK, SUK, CS, SJO, SJL, YH, YPC and MB; Data analysis. SY, JSO, NL, JYK, NK, AWS and DHM. DHM takes full responsibility for the data, analyses and interpretation and the manner in which the research was conducted.

Ethics approval and consent to participate

This study was approved by the Ministry of Food and Drug Safety of Korea and the Asan Medical Center Institutional Review Board (2016-0138). All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and national research committee and with the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards. Informed consent was obtained from all participants included in the study.

Consent for publication

Not applicable.

Competing interests

DHM has received research grants from Life Molecular Imaging GmbH (formerly Piramal Imaging GmbH, Berlin, Germany). NK, MB and AWS are employees of Life Molecular Imaging GmbH, formerly Piramal Imaging GmbH, Berlin, Germany. The other authors declare that they have no conflicts of interest.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Sun Young Chae, Email: sychae@amc.seoul.kr.

Tae-Won Kwon, Email: twkwon2@amc.seoul.kr.

Soyoung Jin, Email: jinsso@naver.com.

Sun U. Kwon, Email: sukwon@amc.seoul.kr

Changhwan Sung, Email: sungch26@naver.com.

Seung Jun Oh, Email: sjoh@amc.seoul.kr.

Sang Ju Lee, Email: atlas425@amc.seoul.kr.

Jungsu S. Oh, Email: jungsu.oh@gmail.com

Youngjin Han, Email: medjin00@gmail.com.

Yong-Pil Cho, Email: ypcho@amc.seoul.kr.

Narae Lee, Email: irkalla84@naver.com.

Ji Young Kim, Email: gift02@hanmail.net.

Norman Koglin, Email: n.koglin@life-mi.com.

Mathias Berndt, Email: m.berndt@life-mi.com.

Andrew W. Stephens, Email: a.stephens@life-mi.com

Dae Hyuk Moon, Phone: 82-2-3010-4592, Email: dhmoon@amc.seoul.kr.

References

  • 1.Mackman N. Triggers, targets and treatments for thrombosis. Nature. 2008;451:914–918. doi: 10.1038/nature06797. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Lozano R, Naghavi M, Foreman K, Lim S, Shibuya K, Aboyans V, et al. Global and regional mortality from 235 causes of death for 20 age groups in 1990 and 2010: a systematic analysis for the global burden of disease study 2010. Lancet. 2012;380:2095–2128. doi: 10.1016/S0140-6736(12)61728-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Benjamin EJ, Virani SS, Callaway CW, Chamberlain AM, Chang AR, Cheng S, et al. Heart disease and stroke Statistics-2018 update: a report from the American Heart Association. Circulation. 2018;137:e67–e492. doi: 10.1161/CIR.0000000000000558. [DOI] [PubMed] [Google Scholar]
  • 4.Wilson PW, D'Agostino RB, Levy D, Belanger AM, Silbershatz H, Kannel WB. Prediction of coronary heart disease using risk factor categories. Circulation. 1998;97:1837–1847. doi: 10.1161/01.CIR.97.18.1837. [DOI] [PubMed] [Google Scholar]
  • 5.Goff DC, Jr, Lloyd-Jones DM, Bennett G, Coady S, D'Agostino RB, Gibbons R, et al. 2013 ACC/AHA guideline on the assessment of cardiovascular risk: a report of the American College of Cardiology/American Heart Association task force on practice guidelines. Circulation. 2014;129:S49–S73. doi: 10.1161/01.cir.0000437741.48606.98. [DOI] [PubMed] [Google Scholar]
  • 6.Detrano R, Guerci AD, Carr JJ, Bild DE, Burke G, Folsom AR, et al. Coronary calcium as a predictor of coronary events in four racial or ethnic groups. N Engl J Med. 2008;358:1336–1345. doi: 10.1056/NEJMoa072100. [DOI] [PubMed] [Google Scholar]
  • 7.Arbab-Zadeh A, Fuster V. The myth of the "vulnerable plaque": transitioning from a focus on individual lesions to atherosclerotic disease burden for coronary artery disease risk assessment. J Am Coll Cardiol. 2015;65:846–855. doi: 10.1016/j.jacc.2014.11.041. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Fleg JL, Stone GW, Fayad ZA, Granada JF, Hatsukami TS, Kolodgie FD, et al. Detection of high-risk atherosclerotic plaque: report of the NHLBI working group on current status and future directions. JACC Cardiovasc Imaging. 2012;5:941–955. doi: 10.1016/j.jcmg.2012.07.007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Stone GW, Maehara A, Lansky AJ, de Bruyne B, Cristea E, Mintz GS, et al. A prospective natural-history study of coronary atherosclerosis. N Engl J Med. 2011;364:226–235. doi: 10.1056/NEJMoa1002358. [DOI] [PubMed] [Google Scholar]
  • 10.Calvert PA, Obaid DR, O'Sullivan M, Shapiro LM, McNab D, Densem CG, et al. Association between IVUS findings and adverse outcomes in patients with coronary artery disease: the VIVA (VH-IVUS in vulnerable atherosclerosis) study. JACC Cardiovasc Imaging. 2011;4:894–901. doi: 10.1016/j.jcmg.2011.05.005. [DOI] [PubMed] [Google Scholar]
  • 11.Cheng JM, Garcia-Garcia HM, de Boer SP, Kardys I, Heo JH, Akkerhuis KM, et al. In vivo detection of high-risk coronary plaques by radiofrequency intravascular ultrasound and cardiovascular outcome: results of the ATHEROREMO-IVUS study. Eur Heart J. 2014;35:639–647. doi: 10.1093/eurheartj/eht484. [DOI] [PubMed] [Google Scholar]
  • 12.Saam T, Hetterich H, Hoffmann V, Yuan C, Dichgans M, Poppert H, et al. Meta-analysis and systematic review of the predictive value of carotid plaque hemorrhage on cerebrovascular events by magnetic resonance imaging. J Am Coll Cardiol. 2013;62:1081–1091. doi: 10.1016/j.jacc.2013.06.015. [DOI] [PubMed] [Google Scholar]
  • 13.Adamson PD, Dweck MR, Newby DE. The vulnerable atherosclerotic plaque: in vivo identification and potential therapeutic avenues. Heart. 2015;101:1755–1766. doi: 10.1136/heartjnl-2014-307099. [DOI] [PubMed] [Google Scholar]
  • 14.Stefanadis C, Antoniou CK, Tsiachris D, Pietri P. Coronary atherosclerotic vulnerable plaque: current perspectives. J Am Heart Assoc. 2017;6:e005543. doi: 10.1161/JAHA.117.005543. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Roffi M, Patrono C, Collet JP, Mueller C, Valgimigli M, Andreotti F, et al. 2015 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: task force for the Management of Acute Coronary Syndromes in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC) Eur Heart J. 2016;37:267–315. doi: 10.1093/eurheartj/ehv320. [DOI] [PubMed] [Google Scholar]
  • 16.Powers WJ, Rabinstein AA, Ackerson T, Adeoye OM, Bambakidis NC, Becker K, et al. 2018 guidelines for the early management of patients with acute ischemic stroke: a guideline for healthcare professionals from the American Heart Association/American Stroke Association. Stroke. 2018;49:e46–e110. doi: 10.1161/STR.0000000000000158. [DOI] [PubMed] [Google Scholar]
  • 17.Mehta SR, Granger CB, Boden WE, Steg PG, Bassand JP, Faxon DP, et al. Early versus delayed invasive intervention in acute coronary syndromes. N Engl J Med. 2009;360:2165–2175. doi: 10.1056/NEJMoa0807986. [DOI] [PubMed] [Google Scholar]
  • 18.Thiele H, Rach J, Klein N, Pfeiffer D, Hartmann A, Hambrecht R, et al. Optimal timing of invasive angiography in stable non-ST-elevation myocardial infarction: the Leipzig immediate versus early and late PercutaneouS coronary intervention triAl in NSTEMI (LIPSIA-NSTEMI trial) Eur Heart J. 2012;33:2035–2043. doi: 10.1093/eurheartj/ehr418. [DOI] [PubMed] [Google Scholar]
  • 19.Bang OY, Lee PH, Joo SY, Lee JS, Joo IS, Huh K. Frequency and mechanisms of stroke recurrence after cryptogenic stroke. Ann Neurol. 2003;54:227–234. doi: 10.1002/ana.10644. [DOI] [PubMed] [Google Scholar]
  • 20.Mazighi M, Labreuche J, Gongora-Rivera F, Duyckaerts C, Hauw JJ, Amarenco P. Autopsy prevalence of intracranial atherosclerosis in patients with fatal stroke. Stroke. 2008;39:1142–1147. doi: 10.1161/STROKEAHA.107.496513. [DOI] [PubMed] [Google Scholar]
  • 21.Mazighi M, Labreuche J, Gongora-Rivera F, Duyckaerts C, Hauw JJ, Amarenco P. Autopsy prevalence of proximal extracranial atherosclerosis in patients with fatal stroke. Stroke. 2009;40:713–718. doi: 10.1161/STROKEAHA.108.514349. [DOI] [PubMed] [Google Scholar]
  • 22.Kim J, Park JE, Nahrendorf M, Kim DE. Direct thrombus imaging in stroke. J Stroke. 2016;18:286–296. doi: 10.5853/jos.2016.00906. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Hellings WE, Peeters W, Moll FL, Piers SR, van Setten J, Van der Spek PJ, et al. Composition of carotid atherosclerotic plaque is associated with cardiovascular outcome: a prognostic study. Circulation. 2010;121:1941–1950. doi: 10.1161/CIRCULATIONAHA.109.887497. [DOI] [PubMed] [Google Scholar]
  • 24.Lohrke J, Siebeneicher H, Berger M, Reinhardt M, Berndt M, Mueller A, et al. 18F-GP1, a novel PET tracer designed for high-sensitivity, low-background detection of thrombi. J Nucl Med. 2017;58:1094–1099. doi: 10.2967/jnumed.116.188896. [DOI] [PubMed] [Google Scholar]
  • 25.Kim C, Lee JS, Han Y, Chae SY, Jin S, Sung C, et al. Glycoprotein IIb/IIIa receptor imaging with (18)F-GP1 positron emission tomography for acute venous thromboembolism: an open-label, non-randomized, first-in-human phase 1 study. J Nucl Med. 2018; 10.2967/jnumed.118.212084. [DOI] [PMC free article] [PubMed]
  • 26.Pedrini L, Dondi M, Magagnoli A, Magnoni F, Pisano E, Del Giudice E, et al. Evaluation of thrombogenicity of fluoropassivated polyester patches following carotid endarterectomy. Ann Vasc Surg. 2001;15:679–683. doi: 10.1007/s100160010129. [DOI] [PubMed] [Google Scholar]
  • 27.Heyligers JM, Verhagen HJ, Rotmans JI, Weeterings C, de Groot PG, Moll FL, et al. Heparin immobilization reduces thrombogenicity of small-caliber expanded polytetrafluoroethylene grafts. J Vasc Surg. 2006;43:587–591. doi: 10.1016/j.jvs.2005.10.038. [DOI] [PubMed] [Google Scholar]
  • 28.van der Steenhoven TJ, Bosman WM, Tersteeg C, Jacobs MJ, Moll FL, de Groot PG, et al. Thrombogenicity of a new injectable biocompatible elastomer for aneurysm exclusion, compared to expanded polytetrafluoroethylene in a human ex vivo model. Eur J Vasc Endovasc Surg. 2012;43:675–680. doi: 10.1016/j.ejvs.2012.02.025. [DOI] [PubMed] [Google Scholar]
  • 29.Tang D, Nickels ML, Tantawy MN, Buck JR, Manning HC. Preclinical imaging evaluation of novel TSPO-PET ligand 2-(5,7-Diethyl-2-(4-(2-[(18)F]fluoroethoxy)phenyl)pyrazolo[1,5-a]pyrimidin-3-yl)- N,N-diethylacetamide ([ (18)F]VUIIS1008) in glioma. Mol Imaging Biol. 2014;16:813–820. doi: 10.1007/s11307-014-0743-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Mackie IJ, Kitchen S, Machin SJ, Lowe GD, Haemostasis, thrombosis task force of the British Committee for Standards in H Guidelines on fibrinogen assays. Br J Haematol. 2003;121:396–404. doi: 10.1046/j.1365-2141.2003.04256.x. [DOI] [PubMed] [Google Scholar]
  • 31.Wahl RL, Jacene H, Kasamon Y, Lodge MA. From RECIST to PERCIST: evolving considerations for PET response criteria in solid tumors. J Nucl Med. 2009;50(Suppl 1):122S–150S. doi: 10.2967/jnumed.108.057307. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Ariyoshi H, Okuyama M, Okahara K, Kawasaki T, Kambayashi J, Sakon M, et al. Expanded polytetrafluoroethylene (ePTFE) vascular graft loses its thrombogenicity six months after implantation. Thromb Res. 1997;88:427–433. doi: 10.1016/S0049-3848(97)00278-8. [DOI] [PubMed] [Google Scholar]
  • 33.Perini P, Massoni CB, Azzarone M, Ucci A, Rossi G, Gallitto E, et al. Title: significance and risk factors for Intraprosthetic mural thrombus in abdominal aortic endografts: a systematic review and meta-analysis. Ann Vasc Surg. 2018; 10.1016/j.avsg.2018.04.027. [DOI] [PubMed]
  • 34.Cornelissen SA, Verhagen HJ, van Herwaarden JA, Vonken EJ, Moll FL, Bartels LW. Lack of thrombus organization in nonshrinking aneurysms years after endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2012;56:938–942. doi: 10.1016/j.jvs.2012.03.015. [DOI] [PubMed] [Google Scholar]
  • 35.Franchi F, Angiolillo DJ. Novel antiplatelet agents in acute coronary syndrome. Nat Rev Cardiol. 2015;12:30–47. doi: 10.1038/nrcardio.2014.156. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Additional file 1: (499.6KB, pdf)

Table S1. Clinical laboratory parameters for safety assessment. Table S2. 18F-GP1 uptake over time. Figure S1. 18F-GP1 PET/CT images of a 76-year-old man with bypass surgery and stent placement. (PDF 499 kb)

Data Availability Statement

All data generated or analysed during this study are included in this published article (and its supplementary information files).


Articles from EJNMMI Research are provided here courtesy of Springer-Verlag

RESOURCES