Abstract
Magnesium (Mg) and its alloys have attracted much attention as a promising candidate for degradable implant applications however the rapid corrosion of magnesium inside the human body greatly limits its use as an implant material. Therefore, coating the alloy surface with a multifunctional film is a promising way to overcome the drawbacks. Here we propose for the first time a multifunction layer coating to enhance the cell viability, antibacterial property and decelerated corrosion rates to act as a novel material to be used for degradable implant Applications. For that, the magnesium alloy (AZ31) was first treated with hydrofluoric acid (HF) and then dopamine tris Hydrochloric acid (tris-HCL) solution. The reducing catechol groups in the polydopamine (PD) layer subsequently immobilize silver/gold ions in situ to form uniformly dispersed Ag/Au nanoparticles on the coating layer. The successful formation of Ag/Au nanoparticles on the HF-PD AZ31 alloy was confirmed using XPS and XRD, and the morphology of all the coated samples were investigated using SEM images. The alloy with HF-PDA exhibit enhanced cell attachment and proliferation. Moreover, the nanoparticle immobilized HF-PD alloy exhibited dramatic corrosion resistance enhancement with superior antibacterial properties and accountable biocompatibility. Thus the result suggest that HF-PD Ag/Au alloy has great potential in the application of degradable implant and the surface modification method is of great significance to determine its properties.
Introduction
In the last few years, magnesium (Mg) and its alloys have attracted much attention as a promising candidate for degradable implant applications such as bone-fixation plates, screws, wires, pins, and stents1, all of which are commonly used during surgical operations such as orthopedic and angioplasty interventions to assist in the healing period and maintain the structural support2. In comparison with other metals, for instance, Titanium and iron are mainly used as implant materials. Titanium is more inert and stable in the human body but is quite expensive and need further surgery after healing process while iron are more economic however, it’s comparatively more reactive when compared to titanium3,4. Co-Cr alloys were also tried but result in adverse host response and acute toxicity. Mg is highly biocompatible and can naturally dissolve in vivo5,6. Furthermore, Mg has comparable physical characteristics regarding natural bone such as Young’s modulus and tensile strength that make it a suitable candidate for implant applications7,8. Although Mg and its alloys can be effectively used in orthopedic temporary-implant applications, they are also susceptible to an accelerated degradation in aqueous environments9,10. To date, extensive research efforts have been directed toward controlling the degradation rate of Mg and its alloys11–13. In most cases, the interfacial characteristics and the interfacial interactions between implants and their surrounding tissue can determine the success of the implantation14. The corrosion rate, osteointegration, and bacterial infection have been identified from among the interfacial processes as the most pertinent in terms of the improvement of new materials and devices for temporary-implant applications15,16. Over the last two decades, several studies have dedicated great effort toward the enhancement of the corrosion resistance and osteointegration of implants by using an Mg coating with different polymers or nanoparticles (NPs)17–19. Learning from nature is endless source of inspiration. In the present section, universal coatings that have been inspired or directly collected from natural biological systems of blood proteins, mussel foot proteins, and plant phenols will be described and discussed. These bioinspired surface coatings bind to substrate surfaces by multiple combined interactions, besides simple chemisorption or physisorption, to enhance the stability of the coatings under different conditions.
Among the different polymers, biomimetic polymers such as mussel-inspired polydopamine (PD) are considered as one of the most attractive types of material for the treatment of metallic alloys to improve the corrosion behavior20. Dopamine is one of the most essential human neurotransmitters, and its ability to form a biocompatible coating is advantageous21,22, along with the advantage of its easy polymerization process in alkaline environments22. Because of this alkaline-polymerization process, PD is an attractive material for a direct-coating formation during the polymerization for which an Mg alloy is immersed in an aqueous solution, as the alkaline solution can minimize the Mg corrosion during the coating formation. Many studies have focused on PD layer23, reporting that the corrosion-current density of PD-coated Mg is lower compared with the bare alloy. Also, several studies have shown that the polydopamine modification of bioceramics significantly promoted the attachment and proliferation of cells due to the improved surface roughness, hydrophilicity, and bioactive functional groups (e.g. OH− and NH2−) of PDA24,25. Moreover, the improvement of apatite mineralization of PDA bioceramics may be the important reason to enhance the adsorption of serum proteins and further improve attachment, proliferation, differentiation and bone-related gene expression of cells25. From these findings, it was proved that PD comprises effective adhesive, cytocompatibility, and anticorrosive activities among the organic and inorganic coatings. Another unique property of a formed PD layer is a strong reductive property. The catechol-PD group is capable of reducing metal ions such as those of silver (Ag) and gold (Au) into NPs22. Therefore, it should be possible to take this advantage to form NPs on the surface of a PD-coated substrate by simply immersing the materials in a dilute metal-ion solution.
Ag or Au NPs displayed many characteristics make them suitable for different applications such as photocatalysis and biosensors26–29. Also there are reports suggesting the diversified application of gold nanoparticles as memory device30,31 and composites of gold with other nanoparticles for photocatalytic and other applications32–34. Apart from these the gold and silver nanoparticle exhibit excellent antibacterial property35. A high infection rate at the bone-implant site has been considered as a major risk accompaniment of medical-implant processes. Therefore, coating an implant with Ag or Au NPs had been shown great benefits due to their antimicrobial, antioxidative, and anticorrosive properties. Zhang et al. studied the Au-NP efficiency against gram-negative and gram-positive bacteria, as Au NPs inhibit the growth and colonization of different kinds of microbes36,37, while reports state that Ag-NP coatings have displayed excellent antibacterial properties that are capable of addressing the bacterial multiplication on implants and other nosocomial infections during surgical procedures38,39. The efficiency of the Ag and Au coatings in controlling the colonization of bacteria around an implant is dependent on the balance between the activity of the cytotoxic metal cation and the concentration of the ions released from the coating36. The high concentration of the cations that are released from the coating can be toxic to cells.
This study is devoted to investigate the effects of Ag and Au NPs enriched PD-hydrofluoric acid (HF)-coated AZ31 alloy, to retard the corrosion of the alloy with improved antibacterial effect with an accountable cytocompatibility under the physiological condition. The successful coating of the HF-treated AZ31 alloy with PD and Ag or Au NPs was confirmed using X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD), and the morphology was investigated using scanning electron microscope (SEM) images. The effectiveness of the polyelectrolyte-multilayer films on the HF-treated Mg alloy was evaluated in terms of the potentiodynamic-polarization test, the in vitro cytocompatibility, and the antibacterial test. The data of the present study indicate that the introduced materials display a sound biocompatibility and enhanced the corrosion resistance. Furthermore, the results revealed that this kind of coating not only improved the corrosion resistance, but it also released the Ag and Au NPs from the alloy surface, thereby providing an excellent antibacterial effect against both gram-positive and gram-negative bacteria species with a minimum toxicity against mammalian cells. The balance between the antibacterial effect and the cell response in consideration of the degradation process makes it an alternative in the application of the surface modification of the Mg alloy in degradable implant applications, and it is anticipated that the proposed surface-modification method can greatly contribute towards the progress of the development of Mg-alloy for medical devices.
Results and Discussion
Surface characterization and phase composition
The characteristic morphology of the coated samples was analyzed using SEM (Fig. 1(A–E)). The SEM image shows that the morphology of bare alloy possesses a passive layer on the surface with cracks and pores; these defects could be unfavorable for long-term corrosion protection, as the corrosive media could penetrate through these defects, leading to an acceleration of the contact between the surface and the corrosive media. However, the PD modified surface, exhibits a homogenous layer of PD covering on the alloy surface to confirm the PD coating. In the HF-PD treated samples, a relatively smoother and crack-free surface has been obtained due to the simultaneous formations of PD and magnesium hydroxide Mg (OH)2 during the coating process. Figure 1(D,E) displayed relatively rougher surfaces with the uniform distribution of small particles on the samples, which indicate the successful in- situ reduction of the metal ions to the metallic NPs by polydopamine in the absence of any reducing agents. The uniform formation of PD on the alloy surface resulted in the synthesis of monodispersed NPs with a minimum degree of aggregation, which is expected to produce a strong antimicrobial effect. The successful coating of PD and the deposition of Ag and Au particles onto the surface were further confirmed using the EDX technique (inset table in Fig. 1) as well as the EDS elemental mapping (Fig. S1 of Supporting Information). Further confirmation of the formation of nanoparticles were carried out using FESEM (Fig. S2 of Supporting Information) and average size has been found to be 168.36 ± 48.5, and 151.03 ± 31.4 for Ag and Au particles respectively.
Phase analyses of the bare AZ31 alloy and the coated samples were analyzed using XRD (Fig. 2). The bare alloy display only Mg peaks whereas the PD coated and HF PD coated samples show the MgO and MgF2 peaks40,41. This is due to the formation of passive oxide layer, and MgF2 on the surface of bare alloy due to HF acid treatment as described below41:
1 |
2 |
The XRD patterns of the Ag- and Au-containing samples were also checked to confirm the formation of the NPs on the surface of the alloy. The Ag peaks were detected at 38.1°, 44.45°, and 63.5° while for Au-containing samples peaks detected at 38.1°, 44.38°, 63.5°, and 77.8°. The detected peaks correspond to the (111), (200), (220), and (311) diffractions of the metallic NPs (JCPDS No. 04–0783).
The chemical compositions of the different coatings on the Mg-alloy substrate surface were characterized via the XPS analysis (Fig. 3). The full XPS spectra for the bare sample show the dominant presence of the Mg1s at 1303.54 eV, the Mg2p at 51.42 eV, and the O1s peaks at 530.18 eV, all of which are related to the Mg oxides. After the coating of the Mg alloy with PD, C1s and N1s peaks appeared for the samples and also the HF- PD treated sample exhibit an extra F1s peak at 692.16 eV (Fig. S3 of the Supporting Information). The XPS scan for the Ag- and Au-containing samples also detected the characteristic phases of both Ag and Au elements in their surface compositions. As shown in Fig. 3, the characteristic Ag3d peak at 367 eV corresponds to the bonding energy of the elemental Ag, and the Au4f was also detected at 95 eV, indicating the successful formation of the Ag and Au particles onto the surface of the coated alloy.
Potentiodynamic test
The degradation behavior of the Mg alloy was assessed using different methods. The potentiodynamic test is an essential test to determine the corrosion resistance of Mg and its alloys. The difference between the metallic potentials of the bare samples and the coated ones is an indication of the corrosion-resistance improvement. Herein, Fig. 4 shows the potentiodynamic-polarization measurements of the bare AZ31 alloy, PD coating, HF PD, and Composite-Ag/Au NPs on the HF-pre-treated PD-coated samples. Magnified images of the potentiodynamic-polarization measurements is given in Fig. S5 of the Supporting Information. The SBF solution was used as an electrolyte to mimic the physiological environment condition, and the solution was prepared according to a previous work42. The obtained results such as the corrosion potential, corrosion-current density, and corrosion rates were calculated and are also listed in Table 1 comparing to the previous coating materials and techniques of the magnesium interface. The different values were calculated using the commercial software ZIVE SM Smart Manager Ver. 5.503. In the electrochemical polarization test, the Mg corrosion potential (Ecorr) explains the relation between the cathodic and anodic reactions during the test, as the anodic one represents the Mg dissociation and the cathodic one displays the hydrogen (H2) evolution43,44. The test results are summarized in Table 1, and the results show that the corrosion-current densities for all of the coated samples are much lower than those of the bare alloy. The values were decreased by means of a dopamine formation on the alloy interface, which also indicates a successful formation of the PD layer. The surface pre-treatment with HF before the addition of the dopamine more retarded the degradation due to the formation of MgF2, which is more stable than Mg(OH)2 in the corrosive media. Moreover, the loading of the Ag and Au NPs on the surface improved the corrosion resistance, as the corresponding polarization-current densities are lower than those of the bare alloy and the HF-PD coated alloy. Thus the potentiodynamic polarization revealed that the corrosion resistance of the coated samples was significantly improved.
Table 1.
Coating Material | Coating Technique | Corrosion properties | Immersion solution | Antibacterial Effect | Ref. | ||
---|---|---|---|---|---|---|---|
ECorr (V) | Icorr (µA/cm2) | CR (mmPY) | |||||
Bare AZ31 | None | −1.48 | 25.137 | 82.24 | SBF | N/A | This study |
Bare-PDA | Dip coating | −1.37 | 5.6 | 18.34 | SBF | N/A | This study |
HF-PDA | Dip coating | −1.45 | 3.189 | 10.43 | SBF | N/A | This study |
HF-PDA-Ag | Dip coating | −1.33 | 2.33 | 7.61 | SBF | Ag | This study |
HF-PDA-Au | Dip coating | −1.17 | 2.47 | 8.07 | SBF | Au | This study |
HA | Aerosol deposition | −1.56 | 4.76 | N/A | SBF | N/A | 54 |
Zn-Ca coating | Dip coating | −1.49 | 11.5 | N/A | 3.5 wt% NaCl | N/A | 55 |
BTSE-coated | Dip coating | N/A | 2.69 | N/A | SBF | N/A | 56 |
PLA | Dip coating | −1.28 | 1.798 | 19.837 | SBF | N/A | 57 |
PCL/ZnO 3wt% | Electrospinning | −1.15 | 2.11 | N/A | SBF | ZnO | 18 |
PCL | Dip coating | −1.5 | 33.5 | N/A | DMEM | N/A | 58 |
SBF/ZrO2 NPs | Anodization | −1.41 | 3.17 | N/A | SBF | N/A | 8 |
Mg-PDA@TiO2 | Dip coating | −1.28 | 2.04 | N/A | PBS | N/A | 59 |
Mg-PDA | Dip coating | −1.54 | 13.85 | N/A | PBS | N/A | 59 |
PLA/ZnO | Dip coating | −0.61 | 0.471 | 5.199 | SBF | ZnO | 60 |
*N/A This mean that not measured or has no effect on antibacterial.
Immersion test
The degradation behavior of the coated samples was also studied by immersing the samples in SBF solution. Figure 5 shows the SEM images of the different samples after immersing in SBF solution. The surface of the bare alloy show cracks due to the severe corrosion and the formation of the Mg(OH)2 layer45. Alternatively, the samples polymerized with PD on the alloy surface resulted in only a few cracks compared to bare alloy, and the HF pre-treated samples showed a more compact surface with small pores as a result of the coating of fluoride layer on the Mg alloy. The role of the corrosion product on the implant surface is also very important in terms of the interaction between the surface and the surrounding tissue. The EDX analysis that was performed at the surface resulted in the presence of the ions of Mg, O, C, N, P, F, Ca, and Cl. The presence of these ions indicate the formations of MgF2, magnesium chloride (MgCl2), Mg(OH)2, Mg phosphate, and Ca; however, the amounts and percentages of these phases depend on the surface pre-treatment and coating. The inset table in Fig. 5 is a summary of the composition that was obtained from the EDX analysis. The bare alloy shows the highest percentage of Cl, which was decreased in the case of the samples pre-treated with HF and coated with PD, and this is due to the Cl− ion interaction with the Mg surface that forms MgCl2 as a corrosion product. Besides the presence of Ca, the presence of P is also indicated that will cause the formation of an apatite layer on the bare alloy surface which facilitate interaction with surrounding media and led to accelerate degradation process. In contrast, the formation of the composite coating act as barrier layer with ability to retard interaction and retard degradation process which confirmed by lower values from these elements, which can be explained by the presence of a successful protection film.
Immersion factors such as immersion solution pH value variation can indicate the corrosion behavior of the coated/uncoated samples. Biodegradability of Mg implant could be represented in chemical equation (3) in terms of pH values.
3 |
Hydroxide group represents the alkalinity of the sample when immersed in the SBF solution. Figure 6. shows the pH measurements in the SBF solution for different samples, where the pH reached the maximum value of 11 for the bare sample. After 7 days of immersion, this alkaline media showed a high degradation of the untreated sample, whereas the coated samples show a much better protection due to the coating effect that can delay the corrosion rate and result in a control of the pH46. Furthermore, the released Ag and Au ions were measured in the PBS solutions of the different samples at different time intervals, as shown in Fig. 7(a,b). The behaviors of the released ions show the increasing of the ions ppm values through the use of the ICP measurements until the steady-state values occurred after 10 days. The initial release occurred gradually, which is not toxic to the cells, as it provides a balance of the biocompatible and antibacterial activities.
Antibacterial test
Clinical infections associated with surgical implants are generally more challenging to control owing to longer period of antibiotic therapies and frequent surgical procedures. Therefore, an effective combination of decent antibacterial function and acceptable cytotoxicity is what the clinic needs, which will be a balanced selection for biodegradable Mg based metals. Hence, the antibacterial effects of the different samples that were obtained from the spectrophotometric-data analysis (Fig. 7c). In this study, the bacterial effects of the bare alloy as a control and PD were compared, along with the HF-PD-coated samples with and without the Ag NPs and Au NPs. The resulting data showed the antibacterial effect of the bare sample against E. coli and S. aureus bacterial types, which explains the hindrance of the bacterial growth that is due to the generation of an alkaline medium in both solutions; this generation is from the degradation of the alloy that is facilitated by the surface corrosion. On the other hand, the PD-coated sample displayed a decreased antibacterial effect that confirmed an improved post coating corrosion resistance. The PD-coated sample after the HF treatment showed a bacterial inhibition due to the F ions, which exert an antibacterial effect47. The coating with the Ag and Au NPs showed the highest antibacterial effects, and this can be explained by the ability of the metal NPs to change the metabolite pathway and release mechanism of the bacterial cells, so that the ions can undergo an ion exchange between the imidazole and thiol groups of the bacteria, leading to a DNA malfunction that deactivates the replication ability of the bacteria48,49. Further, the bactericidal effect in the case of the E. coli is greater than that of the S. aureus, and this can be explained by the thicker cell wall of the S. aureus compared with the E. coli50. The results show a balance between the biocompatibility and antibacterial properties in vitro. The results also confirm that the presence of Ag and Au on the alloy-coating resulted in enhanced antibacterial effects against both the gram-positive and the gram-negative bacteria.
Biocompatibility
Biocompatibility plays a major role in the development of biomaterials. The in vitro cell viability is essential for the evaluation of the biocompatibility of the materials of the present study, and it was evaluated using the CCK-8 assay, as shown in Fig. 8. The biological response and biocompatibility of the bare and coated Mg-alloy samples were assessed using the cellular attachment and growth of MC3T3-E1 mouse osteoblast cells over 1 day. It has been found that the samples coated with PD displayed the highest cell proliferation, thereby revealing the biocompatibility of PD. The mechanism behind the cell proliferation on PD layer could be contributed to the quinone group on PDA coatings induced a larger amount of protein adsorption, and subsequently promoted cell attachment and proliferation38. The HF-PD coated and the Ag and Au NPs loaded samples still showed higher values than the bare alloy, strongly indicating that the coating layer promote the osteoblastic cellular proliferation. MgF2 is an insoluble compound on the alloy surface which improve the corrosion resistance without any cytotoxicity as reported earlier for showing the osteoblastic cell response on fluoridated hydroxyapatite coatings9,38,51,52. Further confirmation of the cell proliferation and adhesion has been carried out by performing the SEM of the cell-seeded surfaces of different samples. Figure 9 shows SEM image showing the interaction between the cell and the material substrates of different samples. On the surface of the bare alloy, only a few cells were observed as attached cells, confirming that the alloy surface cannot provide a suitable substrate for the cells to adhere due to the cracks that are present on its surface. Alternatively, after the polymerization of dopamine on the alloy surface, the bare alloy displayed an enhanced cellular adhesion and growth, as shown in Fig. 9 Consequently, after the treatment of the surface with HF and the PD coating and the Ag and Au NPs formation still showed a considerable cellular attachment and proliferation. The SEM images and cell-viability assay results explain that the coating layer on the Mg samples improves the biocompatibility; furthermore, the incorporation of the metal NPs on the PD coating did not considerably affect the cellular behavior on the Mg substrates, indicating that the coatings containing proper concentrations of the Ag NPs and Au NPs could be acceptable in biomedical applications. The results indicate that the samples loaded with the Ag and Au NPs provided slow and moderate ion releases, thereby achieving a balance between the antibacterial and biocompatible properties.
Conclusion
PD was successfully polymerized on a HF-pre-treated AZ31-alloy surface using a simple and easy immersion method. The uniform layer of PD on the alloy surface resulted in the in-situ reduction of Ag and Au NPs on the surface. The composite coating improved the corrosion resistance of the bare alloy in an SBF solution with a remarkable decrease of the corrosion-current density compared with the bare alloy, moreover has a broad antibacterial effect against the E. coli and S. aureus species, thereby achieving a balance with the biocompatibility that is shown in the cell-culture test. This kind of multifunction composite coating needs greater attention in terms of the surface modification of bio-resorbable Mg and its alloys in degradable implant application.
Experimental
Materials and sample preparation
The samples of the AZ31 Mg alloy (Alfa Aesar Company, Republic of Korea) were cut into the dimensions of 12 × 12 × 6.35 mm to fit them into the holder of the electrochemical cell for the corrosion evaluation. The chemical composition was balanced as Al 3%, Zn 1%, and Mg 96%. Further, these samples were polished with 200, 800, 1200, and 2000 silicon carbide (SiC) abrasive papers, followed by their immersion in ethanol, a 15-min sonication, a washing with distilled water, and then a drying under hot air. Silver nitrate (AgNO3), gold chloride trihydrate (HAuCl4.3H2O), dopamine hydrochloride, and Hank’s balanced salts were purchased from Sigma Aldrich (USA); tris (hydroxy methyl) amino methane (TRIS) 99.0% and the HF were purchased from Samchun (Republic of Korea); sodium chloride (NaCl) was purchased from DaeJung Co., Ltd. (Republic of Korea); and potassium chloride (KCl) was purchased from Showa Co., Ltd. (Japan).
Coating procedure
The AZ31 alloy was coated with the PD using a simple dip-coating method. Briefly, a (50 mL) solution of NaCl (0.4 g), KCl (0.01 g), TRIS (0.15 g), and dopamine hydrochloride (0.02 g/mL) was prepared under a nitrogen (N) environment. The coating has been carried out by immersing the AZ31 alloy in 20 mL of the immersion solution and keeping in the shaker for 3 h at 37 °C and by this time the surface color change was also noted. A different coating condition was achieved by pre-passivating the samples in 48 wt.% HF for 24 h before the coating of the PD layer as described above. The HF was used for the formation of a protective layer of magnesium fluoride (MgF2), which delays the occurrence of corrosion due to the presence of the Cl ion in the immersion solution. In order to reduce the Ag and Au Nps, the HF-PD coated samples were separately kept in 40 mL of distilled water containing the previous weighted Ag nitrate and Au chloride trihydrate particles for 2 h in a shaking incubator. Later, the samples were washed with distilled water to remove the unattached particles, and then they were dried under in a heater.
Coating Characterization
The surface morphology of the samples was investigated using a SEM in the field-emission mode for which a high voltage of 15 kV was applied. The chemical compositions of the samples were evaluated using the XPS and energy dispersive X-ray (EDS) analysis. Aluminium (Al) was used as the anode material of the Thermo/K-Alpha ESCA System. Moreover, the elemental mapping and the composition of the surface were investigated using an energy dispersive spectrometer. Phase analyses of the coated film were measured using XRD (Rigaku, Japan). The average size of the nanoparticles was analyzed using Image J (NIH, USA) software.
In vitro degradation study
An electrochemical corrosion test was performed using a ZIVE SP1 potentiostat/galvanostat device that had been connected to a three-electrode cell containing a simulated body fluid (SBF) solution, which is similar to physiological fluid. Linear-sweep potentiodynamic measurements were recorded with Ag/silver chloride (AgCl) saturated in KCl, platinum (Pt), and a sample serving as the reference, counter, and working electrodes, respectively. The current and voltage ranges are 10 µA and 10 V, respectively, and the initial (E0) and final (E1) potentials during the sweep measurements are −2500 mV and 1500 mV, respectively, with a scan rate of 5.0 mV/s. The surface area of the sample exposed to the solution is 0.875 cm2. All the parameters that were derived using the ZIVE SM Smart Manager Software Ver. 5.503 and the IVMAN Ver. 1.2 testing software are listed in Table 1.
The standard immersion test was performed by immersing the as prepared samples in the SBF solution42, Briefly commercial Hank’s balanced solution (Aldrich, H2387-1, without calcium, sodium and magnesium) mixed with MgSO4 (0.097 g), NaHCO3 (0.35 g), and CaCl2 (0.185 g) in 1 L distilled water and the pH of the solution was maintained at 7.4. The ratio of the surface area to the solution volume was kept as 1:30 cm2/mL53. The immersion test was performed thereafter for 7 days at 37 °C, the surface morphology was investigated using the SEM, and the chemical elemental compositions were evaluated using EDS. Further, the sample biodegradability was analyzed in terms of the pH values of the extraction that were determined at different time intervals. Furthermore, an inductively coupled plasma-optical emission spectroscopy (ICP-OES) instrument was used to measure the amounts of the Ag and Au ions that were released from the bare and coated samples; all of the samples were immersed in a phosphate buffered saline (PBS) solution, which was further diluted before the measurements were taken at different immersion-time intervals, for the inductively coupled plasma (ICP) test.
Antibacterial test
The antibacterial activities of the samples were tested using both gram-positive (Staphylococcus aureus ATCC 29231) and gram-negative (Escherichia coli ATCC 52922) bacteria, which were used as model organisms. The antibacterial properties of the samples against each strain were determined using the spectrophotometric method. Briefly, bacterial cells were grown in Luria-Bertani broth (LB broth, pH 7.2) and incubated at 37 °C for 24 h. Bacterial inoculums were diluted in 20 mL of the LB-broth solution to obtain 107 CFU/mL bacterial cells. The sterile samples were immersed in the bacterial suspension and incubated for 24 h. An LB broth containing the S. aureus and E. coli (107 CFU/mL) was set as the control. Each 100 μL solution from all of the conditions was transferred into a 96-well plate, and the absorbance was measured using an iMarkTM Microplate reader at the wavelength of 620 nm. The cell viability of the bacterial cell in each sample is expressed as a percentage of that of the control.
Biocompatibility test
An in vitro cell-culture test was performed using Dojindo’s cell-counting kit-8 (CCK-8) assay to study the cell proliferation on the different-coating samples. The sample extracts were prepared by immersing the different substrates in each 20 mL complete-culture medium (α-MEM, supplementary with 10% fetal bovine serum and 1% penicillin streptomycin), followed by an incubation at 37 °C for 24 h. Preosteoblast cells (MC3T3-E1, 1 × 104 cells/100 μL) were seeded in a 96-well plate with the culture medium and incubated at 37 °C under 5% carbon dioxide (CO2) for 24 h. The culture medium was later replaced by the extracts and further incubated for 1 and 3 days. Then, 10 μL of the CCK-8 solution was added to each well and they were incubated for 4 h. Later, the absorbance was measured using the iMarkTM Microplate reader at the wavelength of 450 nm. In addition, the morphological behavior of the cells on the surface of the samples was observed using the SEM. The samples were sterilized under a UV ray for 24 h, followed by a rinsing in ethanol. The samples were then placed in 12-well plates and the preosteoblast cells (MC3T3-E1, 1 × 104 cells/well) were seeded directly and incubated at 37 °C under 5% CO2 for different times. Later, the samples were washed with the PBS and fixed in 3.5% glutaraldehyde for 1.5 h. The dehydration of the sample was performed using a series of ethanol solutions (25%, 50%, 75%, and 100%). Lastly, the dried samples were observed using the SEM.
Electronic supplementary material
Acknowledgements
This paper was supported by a grant from the Basic Science Research Program of the National Research Foundation of Korea (NRF) through the Ministry of Education, Science and Technology (Project no. 2016R1A2A2A07005160, Project number: NRF 2016R1D1A1B03934124 and Project no. NRF-2016R1C1B2008296).
Author Contributions
A.I. Rezk is the lead researcher for this work, He performed all of the experiments and wrote the manuscript along with A.R.K. Sasikala. A. Ramachandra Kurup Sasikala, A.G. Nejad contributed on the chemistry aspect of the work especially in the FT-IR and XPS data interpretation, H.M. Mousa contributed on the electrochemical corrosion test, Y.M. Oh, C.H. Park and C.S. Kim supervised the whole experiment.
Competing Interests
The authors declare no competing interests.
Footnotes
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Chan Hee Park, Email: biochan@jbnu.ac.kr.
Cheol Sang Kim, Email: chskim@jbnu.ac.kr.
Electronic supplementary material
Supplementary information accompanies this paper at 10.1038/s41598-018-36545-3.
References
- 1.Song G, Song S. A possible biodegradable magnesium implant material. Adv Eng Mater. 2007;9:298–302. doi: 10.1002/adem.200600252. [DOI] [Google Scholar]
- 2.Mahapatro A. Metals for biomedical applications and devices. Journal of Biomaterials and Tissue Engineering. 2012;2:259–268. doi: 10.1166/jbt.2012.1059. [DOI] [Google Scholar]
- 3.Sul Y-T. The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant. Biomaterials. 2003;24:3893–3907. doi: 10.1016/S0142-9612(03)00261-8. [DOI] [PubMed] [Google Scholar]
- 4.Chou D-T, et al. Novel processing of iron–manganese alloy-based biomaterials by inkjet 3-D printing. Acta Biomaterialia. 2013;9:8593–8603. doi: 10.1016/j.actbio.2013.04.016. [DOI] [PubMed] [Google Scholar]
- 5.Zheng Y, Gu X, Witte F. Biodegradable metals. Materials Science and Engineering: R: Reports. 2014;77:1–34. doi: 10.1016/j.mser.2014.01.001. [DOI] [Google Scholar]
- 6.Xin Y, Hu T, Chu P. In vitro studies of biomedical magnesium alloys in a simulated physiological environment: a review. Acta biomaterialia. 2011;7:1452–1459. doi: 10.1016/j.actbio.2010.12.004. [DOI] [PubMed] [Google Scholar]
- 7.Xu L, Yu G, Zhang E, Pan F, Yang K. In vivo corrosion behavior of Mg‐Mn‐Zn alloy for bone implant application. J Biomed Mater Res A. 2007;83:703–711. doi: 10.1002/jbm.a.31273. [DOI] [PubMed] [Google Scholar]
- 8.Mousa HM, Hussein KH, Woo HM, Park CH, Kim CS. One-step anodization deposition of anticorrosive bioceramic compounds on AZ31B magnesium alloy for biomedical application. Ceramics International. 2015;41:10861–10870. doi: 10.1016/j.ceramint.2015.05.027. [DOI] [Google Scholar]
- 9.Zhang L, Mohammed EA, Adriaens A. Synthesis and electrochemical behavior of a magnesium fluoride-polydopamine-stearic acid composite coating on AZ31 magnesium alloy. Surface and Coatings Technology. 2016;307:56–64. doi: 10.1016/j.surfcoat.2016.08.021. [DOI] [Google Scholar]
- 10.Duygulu, O., Kaya, R. A., Oktay, G. & Kaya, A. A. In Materials science forum. 421–424 (Trans Tech Publ).
- 11.Gray‐Munro JE, Seguin C, Strong M. Influence of surface modification on the in vitro corrosion rate of magnesium alloy AZ31. J Biomed Mater Res A. 2009;91:221–230. doi: 10.1002/jbm.a.32205. [DOI] [PubMed] [Google Scholar]
- 12.Mousa HM, et al. A novel in situ deposition of hydroxyapatite nanoplates using anodization/hydrothermal process onto magnesium alloy surface towards third generation biomaterials. Materials Letters. 2016;164:144–147. doi: 10.1016/j.matlet.2015.10.145. [DOI] [Google Scholar]
- 13.Mousa, H. M., Park, C. H. & Kim, C. S. In Magnesium Alloys (InTech, 2017).
- 14.Rezk AI, Rajan Unnithan A, Hee Park C, Sang Kim C. Rational design of bone extracellular matrix mimicking tri-layered composite nanofibers for bone tissue regeneration. Chemical Engineering Journal. 2018;350:812–823. doi: 10.1016/j.cej.2018.05.185. [DOI] [Google Scholar]
- 15.Zeng R, et al. Self-assembled silane film and silver nanoparticles coating on magnesium alloys for corrosion resistance and antibacterial applications. Acta Metallurgica Sinica (English letters) 2013;26:681–686. doi: 10.1007/s40195-013-0397-0. [DOI] [Google Scholar]
- 16.Wei Z, Tian P, Liu X, Zhou B. Hemocompatibility and selective cell fate of polydopamine-assisted heparinized PEO/PLLA composite coating on biodegradable AZ31 alloy. Colloids and Surfaces B: Biointerfaces. 2014;121:451–460. doi: 10.1016/j.colsurfb.2014.06.036. [DOI] [PubMed] [Google Scholar]
- 17.Mousa HM, et al. Amorphous apatite thin film formation on a biodegradable Mg alloy for bone regeneration: strategy, characterization, biodegradation, and in vitro cell study. RSC Advances. 2016;6:22563–22574. doi: 10.1039/C5RA25306C. [DOI] [Google Scholar]
- 18.Kim J, Mousa HM, Park CH, Kim CS. Enhanced corrosion resistance and biocompatibility of AZ31 Mg alloy using PCL/ZnO NPs via electrospinning. Applied Surface Science. 2017;396:249–258. doi: 10.1016/j.apsusc.2016.10.092. [DOI] [Google Scholar]
- 19.Rezk AI, Mousa HM, Lee J, Park CH, Kim CS. Composite PCL/HA/simvastatin electrospun nanofiber coating on biodegradable Mg alloy for orthopedic implant application. Journal of Coatings Technology and Research. 2018 doi: 10.1007/s11998-018-0126-8. [DOI] [Google Scholar]
- 20.Payra D, et al. Bioinspired adhesive polymer coatings for efficient and versatile corrosion resistance. Rsc Adv. 2015;5:15977–15984. doi: 10.1039/C4RA17196A. [DOI] [Google Scholar]
- 21.Wightman RM, May LJ, Michael AC. Detection of dopamine dynamics in the brain. Analytical Chemistry. 1988;60:769A–793A. doi: 10.1021/ac00164a718. [DOI] [PubMed] [Google Scholar]
- 22.Lee H, Dellatore SM, Miller WM, Messersmith PB. Mussel-inspired surface chemistry for multifunctional coatings. science. 2007;318:426–430. doi: 10.1126/science.1147241. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Singer F, Schlesak M, Mebert C, Höhn S, Virtanen S. Corrosion Properties of Polydopamine Coatings Formed in One-Step Immersion Process on Magnesium. ACS applied materials & interfaces. 2015;7:26758–26766. doi: 10.1021/acsami.5b08760. [DOI] [PubMed] [Google Scholar]
- 24.Xu M, Zhang Y, Zhai D, Chang J, Wu C. Mussel-inspired bioactive ceramics with improved bioactivity, cell proliferation, differentiation and bone-related gene expression of MC3T3 cells. Biomaterials Science. 2013;1:933–941. doi: 10.1039/C3BM60028A. [DOI] [PubMed] [Google Scholar]
- 25.Ding YH, Floren M, Tan W. Mussel-inspired polydopamine for bio-surface functionalization. Biosurface and Biotribology. 2016;2:121–136. doi: 10.1016/j.bsbt.2016.11.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Singh N, Gupta RK, Lee PS. Gold-Nanoparticle-Functionalized In2O3 Nanowires as CO Gas Sensors with a Significant Enhancement in Response. ACS Applied Materials & Interfaces. 2011;3:2246–2252. doi: 10.1021/am101259t. [DOI] [PubMed] [Google Scholar]
- 27.Singh N, Prakash J, Gupta RK. Design and engineering of high-performance photocatalytic systems based on metal oxide–graphene–noble metal nanocomposites. Molecular Systems Design & Engineering. 2017;2:422–439. doi: 10.1039/C7ME00038C. [DOI] [Google Scholar]
- 28.Dinda S, et al. Quantitative Detection with Surface Enhanced Raman Scattering (SERS) Using Self-Assembled Gold Nanoparticle Cluster Arrays. Australian Journal of Chemistry. 2013;66:1034–1038. doi: 10.1071/CH13222. [DOI] [Google Scholar]
- 29.Gupta RK, Ying G, Srinivasan MP, Lee PS. Covalent Assembly of Gold Nanoparticles: An Application toward Transistor Memory. The Journal of Physical Chemistry B. 2012;116:9784–9790. doi: 10.1021/jp3008283. [DOI] [PubMed] [Google Scholar]
- 30.Gupta RK, Krishnamoorthy S, Kusuma DY, Lee PS, Srinivasan M. Enhancing charge-storage capacity of non-volatile memory devices using template-directed assembly of gold nanoparticles. Nanoscale. 2012;4:2296–2300. doi: 10.1039/c2nr12134d. [DOI] [PubMed] [Google Scholar]
- 31.Gupta RK, Kusuma DY, Lee P, Srinivasan M. Covalent assembly of gold nanoparticles for nonvolatile memory applications. ACS applied materials & interfaces. 2011;3:4619–4625. doi: 10.1021/am201022v. [DOI] [PubMed] [Google Scholar]
- 32.Misra M, Singh N, Gupta RK. Enhanced visible-light-driven photocatalytic activity of Au@ Ag core–shell bimetallic nanoparticles immobilized on electrospun TiO 2 nanofibers for degradation of organic compounds. Catalysis Science & Technology. 2017;7:570–580. doi: 10.1039/C6CY02085B. [DOI] [Google Scholar]
- 33.Prakash J, Sun S, Swart HC, Gupta RK. Noble metals-TiO 2 nanocomposites: From fundamental mechanisms to photocatalysis, surface enhanced Raman scattering and antibacterial applications. Applied Materials Today. 2018;11:82–135. doi: 10.1016/j.apmt.2018.02.002. [DOI] [Google Scholar]
- 34.Singh N, Ponzoni A, Gupta RK, Lee PS, Comini E. Synthesis of In2O3–ZnO core–shell nanowires and their application in gas sensing. Sensors and Actuators B: Chemical. 2011;160:1346–1351. doi: 10.1016/j.snb.2011.09.073. [DOI] [Google Scholar]
- 35.Guerra R, Lima E, Guzmán A. Antimicrobial supported nanoparticles: Gold versus silver for the cases of Escherichia coli and Salmonella typhi. Microporous and Mesoporous Materials. 2013;170:62–66. doi: 10.1016/j.micromeso.2012.11.036. [DOI] [Google Scholar]
- 36.Dastjerdi R, Montazer M. A review on the application of inorganic nano-structured materials in the modification of textiles: focus on anti-microbial properties. Colloids and Surfaces B: Biointerfaces. 2010;79:5–18. doi: 10.1016/j.colsurfb.2010.03.029. [DOI] [PubMed] [Google Scholar]
- 37.Zhang Y, Peng H, Huang W, Zhou Y, Yan D. Facile preparation and characterization of highly antimicrobial colloid Ag or Au nanoparticles. J Colloid Interf Sci. 2008;325:371–376. doi: 10.1016/j.jcis.2008.05.063. [DOI] [PubMed] [Google Scholar]
- 38.Zhao C, et al. Ag-Incorporated FHA Coating on Pure Mg: Degradation and in Vitro Antibacterial Properties. ACS Applied Materials & Interfaces. 2016;8:5093–5103. doi: 10.1021/acsami.5b10825. [DOI] [PubMed] [Google Scholar]
- 39.Zhang X, et al. Layer-by-layer assembly of silver nanoparticles embedded polyelectrolyte multilayer on magnesium alloy with enhanced antibacterial property. Surface and Coatings Technology. 2016;286:103–112. doi: 10.1016/j.surfcoat.2015.12.018. [DOI] [Google Scholar]
- 40.Cui X-J, et al. Phosphate film free of chromate, fluoride and nitrite on AZ31 magnesium alloy and its corrosion resistance. T Nonferr Metal Soc. 2012;22:2713–2718. doi: 10.1016/S1003-6326(11)61522-7. [DOI] [Google Scholar]
- 41.Narayanan TS, Park IS, Lee MH. Tailoring the composition of fluoride conversion coatings to achieve better corrosion protection of magnesium for biomedical applications. J Mater Chem B. 2014;2:3365–3382. doi: 10.1039/C3TB21565B. [DOI] [PubMed] [Google Scholar]
- 42.Mousa HM, Lee DH, Park CH, Kim CS. A novel simple strategy for in situ deposition of apatite layer on AZ31B magnesium alloy for bone tissue regeneration. Applied Surface Science. 2015;351:55–65. doi: 10.1016/j.apsusc.2015.05.099. [DOI] [Google Scholar]
- 43.Song GL, Atrens A. Corrosion mechanisms of magnesium alloys. Adv Eng Mater. 1999;1:11–33. doi: 10.1002/(SICI)1527-2648(199909)1:1<11::AID-ADEM11>3.0.CO;2-N. [DOI] [Google Scholar]
- 44.Shi Z, Liu M, Atrens A. Measurement of the corrosion rate of magnesium alloys using Tafel extrapolation. Corros Sci. 2010;52:579–588. doi: 10.1016/j.corsci.2009.10.016. [DOI] [Google Scholar]
- 45.Zhang L, et al. Study on the anodic film formation process of AZ91D magnesium alloy. Electrochimica Acta. 2007;52:5325–5333. doi: 10.1016/j.electacta.2006.12.083. [DOI] [Google Scholar]
- 46.Hanas T, Sampath Kumar TS, Perumal G, Doble M. Tailoring degradation of AZ31 alloy by surface pre-treatment and electrospun PCL fibrous coating. Materials Science and Engineering: C. 2016;65:43–50. doi: 10.1016/j.msec.2016.04.017. [DOI] [PubMed] [Google Scholar]
- 47.Yap A, Khor E, Foo S. Fluoride release and antibacterial properties of new-generation tooth colored restoratives. Operative dentistry. 1999;24:297–305. [PubMed] [Google Scholar]
- 48.DeVasConCellos P, Bose S, Beyenal H, Bandyopadhyay A, Zirkle LG. Antimicrobial particulate silver coatings on stainless steel implants for fracture management. Materials Science and Engineering: C. 2012;32:1112–1120. doi: 10.1016/j.msec.2012.02.020. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Zille A, et al. Size and aging effects on antimicrobial efficiency of silver nanoparticles coated on polyamide fabrics activated by atmospheric DBD plasma. ACS applied materials & interfaces. 2015;7:13731–13744. doi: 10.1021/acsami.5b04340. [DOI] [PubMed] [Google Scholar]
- 50.Kim J-S. Antibacterial activity of Ag+ ion-containing silver nanoparticles prepared using the alcohol reduction method. Journal of Industrial and Engineering Chemistry. 2007;13:718–722. [Google Scholar]
- 51.Wang Y, et al. Osteoblastic cell response on fluoridated hydroxyapatite coatings. Acta Biomater. 2007;3:191–197. doi: 10.1016/j.actbio.2006.10.002. [DOI] [PubMed] [Google Scholar]
- 52.Cai Y, et al. Osteoblastic cell response on fluoridated hydroxyapatite coatings: the effect of magnesium incorporation. Biomedical Materials. 2010;5:054114. doi: 10.1088/1748-6041/5/5/054114. [DOI] [PubMed] [Google Scholar]
- 53.Mousa HM, et al. In vitro degradation behavior and cytocompatibility of a bioceramic anodization films on the biodegradable magnesium alloy. Colloids and Surfaces A: Physicochemical and Engineering Aspects. 2016;488:82–92. doi: 10.1016/j.colsurfa.2015.10.003. [DOI] [Google Scholar]
- 54.Hahn B-D, et al. Aerosol deposition of hydroxyapatite–chitosan composite coatings on biodegradable magnesium alloy. Surface and Coatings Technology. 2011;205:3112–3118. doi: 10.1016/j.surfcoat.2010.11.029. [DOI] [Google Scholar]
- 55.Zeng R, Lan Z, Kong L, Huang Y, Cui H. Characterization of calcium-modified zinc phosphate conversion coatings and their influences on corrosion resistance of AZ31 alloy. Surface and Coatings Technology. 2011;205:3347–3355. doi: 10.1016/j.surfcoat.2010.11.027. [DOI] [Google Scholar]
- 56.Liu X, et al. Biofunctionalized anti-corrosive silane coatings for magnesium alloys. Acta Biomater. 2013;9:8671–8677. doi: 10.1016/j.actbio.2012.12.025. [DOI] [PubMed] [Google Scholar]
- 57.Mousa HM, et al. A Multifunctional Zinc Oxide/Poly (Lactic Acid) Nanocomposite Layer Coated on Magnesium Alloys for Controlled Degradation and Antibacterial Function. ACS Biomaterials Science & Engineering. 2018;4:2169–2180. doi: 10.1021/acsbiomaterials.8b00277. [DOI] [PubMed] [Google Scholar]
- 58.Ostrowski N, et al. Corrosion protection and improved cytocompatibility of biodegradable polymeric layer-by-layer coatings on AZ31 magnesium alloys. Acta Biomater. 2013;9:8704–8713. doi: 10.1016/j.actbio.2013.05.010. [DOI] [PubMed] [Google Scholar]
- 59.Chen Y, et al. Sandwiched polydopamine (PDA) layer for titanium dioxide (TiO2) coating on magnesium to enhance corrosion protection. Corrosion Science. 2015;96:67–73. doi: 10.1016/j.corsci.2015.03.020. [DOI] [Google Scholar]
- 60.Mousa HM, et al. A Multifunctional Zinc Oxide/Poly(Lactic Acid) Nanocomposite Layer Coated on Magnesium Alloys for Controlled Degradation and Antibacterial Function. ACS Biomaterials Science & Engineering. 2018;4:2169–2180. doi: 10.1021/acsbiomaterials.8b00277. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.