Skip to main content
. 2018 Nov 19;15(4):306–322. doi: 10.14245/ns.1836206.103

Table 1.

Comparison of the performance of different imaging techniques

Variable Ultrasound Photoacoustic imaging Fluorescence imaging MRI PET
Type of energy measured High-frequency sound waves High-frequency sound waves Visible or near-infra- red light Radio waves High energy gamma rays
Spatial resolution 50–500 μm 50–500 μm 2–10 mm (depth dependent) 20–100 μm 1–2 mm
Time resolution Seconds to minutes Seconds to minutes Seconds Minutes to hours Minutes
Sensitivity Not well characterized pM nM μM–mM pM
Depth < 5 cm < 5 cm < 5 mm No limit No limit
Type of contrast agents Microbubble Nanoparticle/micro-bubble Small molecules nanoparticle Small molecules nanoparticle Small molecules nanoparticle
Cost Low Low Medium High High

MRI, magnetic resonance imaging; PET, positron emission tomography.