Abstract
Diabetes technologies are an unstoppable phenomenon. They offer opportunities to improve patient self-care through empowerment. However, they can be a challenge for both patients and clinicians. Thus, the use of technology may empower or burden. To understand and benefit from the use of diabetes technologies, one must understand the currently unmet needs in diabetes management. These unmet needs call for perspectives beyond glycated hemoglobin and an evaluation of technology solutions. Optimal use of these technologies is necessary to obtain benefits and achieve cost-effectiveness; this process depends on diabetes education and training. This review evaluates clinician and patient perspectives regarding diabetes technologies, followed by an evaluation of technology solutions. Diabetes technology solutions are evaluated according to available results about their effectiveness and their potential to empower people living with diabetes.
Keywords: biomedical technology, diabetes mellitus, therapy, patient participation, self-care
Introduction
Optimization of glycemic control has shown to reduce diabetes complications. Glycated hemoglobin (HbA1c) has proven to be helpful in long-term glucose management; however, it is useless on a daily basis given that it does not provide any information regarding glucose variability. In general, a high burden of diabetes management is still present on a daily basis. For most people living with diabetes, glycemic control optimization involves important and constant decision-making; and for many a continuous struggle between hyperglycemia and hypoglycemia due to glycemic variability. In this context, feelings of powerlessness and futility are commonly reported sources of diabetes distress, as well as fear of chronic complications, hypoglycemia risk and stigma in the working and social environments.1–3 These sources of distress are common barriers that limit treatment adherence, quality of life and glycemic control.2
Diabetes technologies have shown to improve health outcomes.4,5 They are evolving to offer more precise treatments increase glucose information, safety and discretion. They may offer solutions to overcome frequently encountered barriers, and empower people living with diabetes. However, diabetes technologies and devices may also be sources of burden if approached inappropriately. This paper reviews the literature regarding patient and clinician perspectives on the use of diabetes technologies, suggestions to improve patient self-care and an overview of the pros and cons of some of the potential technology solutions. The main limitation of this review is the growing number of potential technology solutions becoming available; only the most relevant to self-care will be discussed.
Patient and clinician perspectives on the use of diabetes technologies
Studies have found that diabetes technologies in general do not seem to decrease diabetes distress scores, nor do they increase them.6 However, as technology becomes friendlier and more effective for performing automatic tasks, users do report a reduced sense of burden of diabetes and an increase in quality of life.6–8
Most patients consider adaptability of diabetes devices a key desirable characteristic. In interview studies, users describe an effective diabetes device as the one that will easily become a part of their own selves in their daily lives.9 Also, a diabetes technology or device should provide enough advantages, for it to be worthwhile considering the learning curve required to incorporate its use on a daily basis and other potential costs. Potential advantages include discretion, safety, precision, and availability of more glucose and performance information. When these advantages can be provided by a device or technology and the individual feels the learning curve is affordable, then it is the right device for them and adherence is more likely to be achieved.10
Adherence to diabetes technologies and devices is directly related to improved glycemic control. However, studies show that adherence is still hard to achieve and sustain, tending to decrease in time, especially in adolescent populations.6,11 A reason for this may be that the use of diabetes technologies requires multiple behaviors and tasks on a daily, weekly or monthly basis. These behaviors and tasks may include responding to continuous glucose monitoring (CGM) readings and alarms, administering insulin boluses, refilling or replacing insulin cartridges, keeping sensors in place, replacing them, charging batteries, among many others. Fortunately, some of these tasks have become simpler or nonexistent with the development of simpler and more automatic devices.12
Human factors are also involved in the differences between a patient’s response, regarding adherence, treatment success and satisfaction.6,13,14 Uptake of technology solutions depends on individual characteristics and also on specific treatment modalities. As an example of this, Naranjo and colleagues, in an interview study, found that multiple doses of insulin (MDI) and blood glucose meter (BGM) users had more negative opinions regarding diabetes technologies than pump and CGM users.6
Clinicians’ main concerns are: costs, achieving adherence and the learning curves involved in the use of diabetes technologies both for patients and health professionals. A study comparing clinician versus patient perspectives, found discrepancies regarding the reported barriers.10 In this study younger health professionals tended to prescribe and use more diabetes technologies with their patients and had more positive opinions regarding diabetes technologies compared with older clinicians. The barriers that both patients and clinicians agreed on as the most frequently encountered were technology costs and lack of healthcare system coverage. However, large discrepancies were found in reported modifiable barriers such as: patients not wanting to wear a device on them or patients not knowing how to handle the device or the information provided by it. In general, clinicians reported a larger number of modifiable barriers to the use of diabetes technologies than adult patients with type 1 diabetes. In a previous study by James and colleagues, similar discrepancies were shown when evaluating diabetes educators’ intended use versus their actual use of diabetes technologies.15 These results suggest a need for specific training to improve the prescription and use of diabetes technologies among healthcare providers.
The use of diabetes technologies has tended to increase in North America and European countries in the past 10 years. However, very different approaches and rates of coverage have been achieved depending on the country’s healthcare system structure and resources.16,17 Large transatlantic registry comparisons have shown differences in metabolic outcomes, in spite of similar population characteristics, partly in relation to the different frequencies of use of diabetes technologies.18 Cost-effectiveness of diabetes technologies has also shown differences depending on the type of technology, setting, healthcare system structure and the endpoints considered.16,19–23 On the other hand, there is a potential high economic burden from healthcare resource waste associated with nonadherence or early discontinuation. Shengsheng and colleagues, reported an estimated resource waste of US$72,648 to $220,289, and $5,675 to $21,775 for every 100 patients initiating CGM, for nonadherence and early discontinuation respectively.16 These results suggest the need for tailored approaches to individualize diabetes therapy to achieve an optimal use of diabetes technologies and devices.
Diabetes education is key to approaching an optimal use of diabetes technologies.4,10,13 A team composed of certified diabetes educators, physicians and other healthcare professionals in a patient-centered approach best performs this process.24 Psychosocial techniques involving direct questioning and motivational interviewing are the recommended strategies to approach tailored treatments and overcome most of the barriers encountered in the use of diabetes technologies.11,13,24,25 Direct questioning must be directed to explore patients’ expectations and needs, contrasting with reality and what a specific technology or device can actually do for them. Questioning must also be directed to explore real-life scenarios and how a device or technology may be used in those specific situations; this will promote and develop the problem-solving skills required to deal with diabetes on a daily basis.25
Solutions offered by diabetes technologies
Technology solutions offer opportunities to improve self-management through empowerment. These opportunities include increased safety, support, self-efficacy through the use of information, and comfort. Safety includes hypoglycemia prevention and achieving glycemic control beyond HbA1c. Support sources include communities and communication with healthcare providers. Self-efficacy sources include increased information on performance and accomplishments; having one’s own experience as a reinforcement is empowering.26 Comfort may come from devices that reduce the diabetes burden by offering decision aids, or that favor normalization and discretion.9
Automated bolus calculators
Automated bolus calculators (ABCs) are incorporated into insulin infusion systems, BGMs and diabetes mobile applications. The use of ABCs coupled with advanced carbohydrate counting has shown HbA1c improvements, increases in treatment satisfaction, and reductions of hypoglycemia and the fear of hypoglycemia.27–33 Useful features include accounting for insulin on board, and adjustments for special situations such as exercise, the menstrual cycle, stress or ailments.
The main cons of this technology are: there are still scarce data about real-life and long-term use, lack of standardization (not all ABCs perform insulin-dosing calculations the same way) and that they still rely on advanced carbohydrate counting.34
New advances include ABCs that are coupled with insulin-dosing pens. These so-called ‘smart pens’ allow users to track and account for previous insulin doses, preventing insulin dose stacking. Other interesting features are: tracking the insulin temperature and expiration date. Both patients and clinicians have a better control of the treatment that is being administered. This degree of control on insulin dosing was previously only available for insulin pump users; with this technology, now it may also be available for MDI users.35
Continuous glucose monitoring
CGM offers large amounts of glucose information at almost zero effort from its users. Intermittently viewed CGM (iCGM) offers this same amount of information on demand in a retrospective manner. Devices that perform real-time CGM (rtCGM) provide data and the possibility of incorporating alarms to alert the user of rapid glucose drops or glucose excursions. These features of rtCGM also allow for insulin infusion suspension for pump users. The use of these devices both for pump and MDI users, has shown improvements in HbA1c of −0.3–0.6% without increasing hypoglycemia, and hypoglycemia reductions of up to 72% in people with type 1 diabetes with hypoglycemia unawareness.36,37
The large amount of glucose information provided by CGM might be overwhelming for both patients and clinicians; especially considering the time restrictions frequently encountered in diabetes care appointments. The ambulatory glucose profile (AGP) is a tool for standard report and visualization of CGM data. An AGP should provide the key 15 CGM metrics that enable optimal analysis and allow for treatment-related decision-making. For optimal AGP interpretation, a minimum of 14 consecutive days of data with approximately 70% CGM readings is required.36
CGM coupled with AGP, has enabled another type of glucose management; one that is more dynamic and goes beyond the HbA1c metric. As mentioned before, HbA1c does not provide any information regarding daily glucose variability. In contrast, CGM provides metrics that have a practical impact on a daily basis. An example of this is the so-called ‘time in range’ (TIR) or time in target range. TIR can be expressed as the percentage of CGM readings that are in the target glucose range or as hours per day spent in the target glucose range. Target glucose range should be individualized according to patient needs; a generally suggested range is 70–180 mg/dl. Although it is not the only metric to evaluate in an AGP, TIR directly expresses whether glucose control is on the right track with an acceptable amount of variability. Other AGP metrics that are important for safety reasons are: time spent in hypoglycemia by thresholds and number of events. The hypoglycemia alert threshold (level 1) refers to glucose readings <70–54 mg/dl. Having <3–5% of time spent in this range is a desired result. Clinically significant hypoglycemia (level 2) threshold is defined as a glucose <54 mg/dl. Severe hypoglycemia (level 3) threshold is not defined numerically but as a state of need for external help.36 These metrics, together with graphic visualizations are easy for both patients and clinicians to understand and act on. They directly inform people living with diabetes about their daily safety and achievements.
To have enough information to act upon and then evaluate achievements on a daily basis is a source for empowerment in itself. In this sense, an observational study about CGM has shown that most users feel safer and more in control when using CGM devices. Users reportedly felt CGM was an empowering tool because they could see glucose readings in real-time almost effortlessly. Data were very easy to act upon by interpreting trend arrows as a visual guide for the rate of change. These data had a practical impact in short-term daily life planning. In this study, users also seemed empowered for long-term lifestyle changes. Users could see the impact of certain foods and activities on their glucose curves in a dynamic fashion. They felt the need to introduce lifestyle changes to further improve their glucose readings and to see the improvements achieved when those changes were applied.
The use of alarms has proven to be effective, especially for reducing hypoglycemia; however, users regard alarms with ambivalence. Some users have discretion complaints, since they feel uncomfortable with alarms going off in their work or school environments. Though seemingly innocuous, excessive alarms can be stressful and can have side effects. An extreme example of this is an event with excessive repeated night-time alarms that could favor the onset of seizures due to stress and sleep deprivation in a predisposed individual.38 This is an extreme and rare situation in clinical practice but should be taken as a reminder for the need of individualized approaches to alarms. Alarms are highly important for patients with hypoglycemia unawareness, while regarded as unnecessary or even intrusive by other users who are not afflicted by this condition.13 The main strategy to cope with this issue is to program and use alarms judiciously. They should be programmed and agreed upon by both clinicians and patients, and most importantly patients should be instructed on how to act in response to these alarms. More recent systems have incorporated discrete vibratory alarms that are highly accepted by patients.39
CGM devices have become more accurate. Mean absolute relative difference (MARD) is the statistic frequently used to evaluate accuracy. MARD is the mean of the sum of the differences between reference and sensor readings divided by the number of observations. This statistic has its caveats; however, it may serve as a reference of how newer CGM systems tend to be more accurate. While older systems had MARDs of up to 15 or 20%, newer systems have MARDs of 9–11%. Expert consensus statements suggest the appropriate MARD to enable insulin dosing should be <10%.40
Even though accuracy has improved in current CGM systems and different technologies are being studied, most of glucose sensing is still performed in the interstitial fluid.41 There will always be differences between interstitial fluid glucose when compared with blood glucose readings. Some devices require frequent manual calibrations with BGM readings. The difference between interstitial and capillary readings may decrease users’ confidence in some of these devices. Situations in which glucose is changing rapidly such as postprandial states or during exercise are especially prone to these discrepancies. In fact, expert patients as well as recent studies have found discrepancies in trending arrows and the expected glucose values in these situations.42 To overcome this issue, health professionals should always explain the expected lag, differences between these two types of readings and instruct their patients to perform BGM accordingly. BGM readings are still recommended for these specific scenarios: during the first 24 h after a new sensor application, when a trending arrow shows low, even if there are no symptoms or when symptoms suggest a low even if the reading and trend do not, before driving according to some European Union and United Kingdom legislations although this will soon change,43 when taking new medications that could interfere with the sensor.44 Another issue regarding interstitial fluid sensing is the tissue’s response to the device. A recent study showed that macrophage activity at the insertion site is related to the sensor’s decreased accuracy.45 Understanding this process is an important step in the research towards safer and longer-lasting sensors.
The main cons for CGM are still cost and coverage by healthcare systems.
There are mixed results from studies regarding cost-effectiveness depending on the setting, the healthcare structure, the endpoints and methodology used.19,46–49 However, several studies have shown reduced incremental cost-effectiveness per quality-adjusted life year (QALY) gained at different HbA1c thresholds. Results for all HbA1c thresholds were below the willingness-to-pay threshold of US$100 per QALY for people living with diabetes. For higher HbA1c thresholds the benefit is larger.49–51 On the other hand, economic waste from nonadherence or early discontinuation, have been estimated and reported in different settings.47 Optimal use of these technologies is required to avoid this loss.
Another issue with cost-effectiveness is that until recently, glucose readings from CGM systems alone were not recommended for supporting insulin-dosing decisions. Recent studies however, have shown CGM is as well tolerated and effective for insulin dosing as standard BGM readings.52 There are proposed algorithms to interpret trend arrows into treatment decisions.53 In response, systems of CGM have been approved as a tool for insulin-dosing decisions without BGM readings, except for the specific scenarios mentioned before. As sensors become more precise and more expert societies approve the use of CGM to enable treatment decisions and insulin dosing, CGM might be able to reduce BGM use in a larger number of patients. This would imply reducing costs in BGM strip use and still improve glucose control by incorporating a better control of glycemic variability.
Intermittently viewed continuous glucose monitoring
The so-called ‘flash’ glucose monitoring system is a type of iCGM in which glucose readings can be visualized on demand by scanning the sensor with a meter or a smartphone. Studies have found the iCGM system has a similar accuracy and efficacy as other CGM devices.54,55 iCGM use has shown improvements in quality of life and sense of wellbeing and benefits for special populations, such as pediatric and pregnant women.56,57
These devices share most of the empowering characteristics already mentioned for CGM.55 Given the sensor’s duration and accessible cost, they have brought most of the benefits of CGM to a wider proportion of people living with diabetes. Another positively valued characteristic is that these devices do not require manual calibrations, since they are factory calibrated.
The main concern regarding iCGM is that given its intermittent nature, these devices are not equipped with alarms. For this reason, iCGM is not currently recommended for people with hypoglycemia unawareness.58 Other frequently reported issues are dermal reactions at the insertion site or to the sensor’s adhesive, with a reported frequency of up to 11.5% in a controlled study.59 This is a very important limitation considering that the sensor must remain in place for 14 days to provide glucose readings.
Preliminary results suggest iCGM will probably be found to be cost-effective in most settings of developed countries. A study from the United Kingdom suggests iCGM is cost-effective for people who require more frequent testing.60
Implantable long-term CGM sensors
An implantable subcutaneous fluorescence-based glucose sensor has demonstrated accuracy and benefits in long-term use.39,61 The first devices worked for periods of 90 days, now they are available for up to 180 days and the pipeline’s direction is to further extend this duration.
The main benefit of this system is the sensor’s duration, which can potentially increase adherence to CGM use with all the previously mentioned advantages.49 Other potential benefits for users are: avoiding frequent sensor insertions, no interferences with common use substances like acetaminophen or ascorbic acid,62 silent vibration alarms offer safety while not sacrificing discretion, and compatibility with all types of physical activities given that the transmitter unit may be detached as needed.
Although this system’s cost is still an issue in most settings, the possibility of long-term use facilitates adherence and optimal use.49 If these goals are achieved the system’s cost-effectiveness may be better when compared to other CGM systems with short-term sensors.49
Integrated systems
Diabetes technologies are approaching the artificial pancreas with developments that go from the sensor-augmented pump (SAP), to hybrid closed loop systems.
SAP technologies have achieved significant reductions of nocturnal hypoglycemia and a TIR of up to 62% when using the function of low-threshold glucose suspension of insulin infusion.63 This hypoglycemia reduction was achieved without increasing HbA1c or ketosis. Furthermore, the function of predictive low glucose suspension, available in several SAP systems, allows for insulin infusion to be stopped when an algorithm predicts a low. Predictive low glucose suspension effectively reduces hypoglycemia events in patients with type 1 diabetes of all age groups without increasing adverse events.64,65
Control algorithms and machine learning allow for a feedback loop between sensor and insulin delivery. Proportional-integral-derivative control algorithms assess glucose excursions by using the difference from target glucose level, glucose area under the curve, and glucose rate of change. Model predictive controllers are more complex, consisting of mathematical models that relate insulin delivery and meal ingestion to glucose excursions. Some of these models have the capability to improve as more data get introduced and therefore ‘become smarter’. This is a trending area of research, given the benefit for diabetes technologies among many other fields. These benefits go from supporting insulin-dosing decisions, to controlling the rates of insulin infusion approaching the artificial pancreas.
The artificial pancreas is approached through closed loop insulin delivery. Fully automatic insulin delivery is still not possible. Partially automatic delivery is possible with a hybrid closed loop system. The hybrid closed loop has achieved a TIR as high as 73%.66 This modality has shown to be fit to control basal insulin rate. A recent study proved personalized model predictive control in a hybrid closed loop also performed well in situations of overestimated, missed or extended meal boluses in adults with type 1 diabetes.67
Even though technological advances have been great, barriers to the fully artificial pancreas still remain. There are good clinical and in silico results of basal insulin control in closed loop systems, but the prandial and exercise scenarios are still challenging. Current hybrid loop systems require user input for these specific scenarios. Another barrier is that the peak insulin action is variable between patients and rapid-acting insulin analogues. New ultra-rapid-acting insulin may have more appropriate pharmacokinetics and improve this situation. Another barrier is subcutaneous insulin infusion; it is not ideal for postprandial glucose control. However, peritoneal insulin delivery has not been fully accepted due to its elevated costs, potential complications and limited experience.
The main cons for the use of integrated systems are cost and coverage. Most studies show increases in treatment satisfaction and quality of life with the use of integrated systems. In observational studies, users have reported an increased sense of wellbeing, improved sleep, reduced worries for hypoglycemia and less burden of diabetes, when using integrated systems.68,69 Although more studies are warranted, the significant reductions of hypoglycemia provided by integrated systems will probably render them cost-effective in most settings for at-risk populations with hypoglycemia unawareness. However, coverage remains low especially for hybrid loop technology, given that, until recently, they were only commercially available in North America. More ongoing studies will probably support its approval in other countries.70
Telemedicine
Telemedicine offers care at a distance. For diabetes, telemedicine has shown promising results offering continued support in ongoing treatments and education, reducing costs in medication and screening for diabetes retinopathy.23,71–75
Cons for this technology are: initial costs, coverage, data security issues, technical requirements and support. New technology solutions are under way to enable wider telemedicine coverage and facilitate their integration into healthcare systems for ongoing treatments and prevention of diabetes.23,76
Applications, wearables and smartphone technologies
Applications and smartphone technologies offer technological solutions for telemedicine, social interaction, exercise monitoring, and specific diabetes health platforms.
Diabetes health platforms have built a diabetes digital ecosystem by incorporating large amounts of real-world data. Applications like MySugr, Glooko, One Drop, Livongo or Social Diabetes have achieved estimated HbA1c drops of −1.0% to −2.0%, reductions of hypoglycemia and low blood glucose indexes.77–81 Gamification characteristics of some of these applications have shown to be of interest to promote user engagement and adherence.77
More applications for smart CGMs and decision aids in insulin dosing are being powered by machine learning.82,83 Other trending areas within the diabetes technology research fields are for food recognition systems. Computer vision-based carbohydrate counting is being studied with promising results.84
Although it is unstoppable, the cons to mobile technology are mainly related to data security and personal data protection. A lot of these applications do not allow the user to limit the information they wish to share with the platform, and this may imply a privacy violation for some users.
Blogs, forums, social media and internet communities
Although these are not specific diabetes technologies, they allow for social interaction of people living with diabetes. An important sense of support may come from sharing experiences, connections or even technical support. As an example of this, social media use has shown an added value for self-management in chronic conditions, including diabetes.85,86
Do-it-yourself online communities, supported by engineers, bioinformatics and expert patients managed to get CGM on the Cloud. Self-reported benefits of real-world use include significant improvements of HbA1c and quality of life.87 This patient-driven effort uses the slogan ‘we are not waiting to reduce the burden of type 1 diabetes’, and continues to work for more people to access integrated systems (openaps.org). The Juvenile Diabetes Research Foundation has called for research on do-it-yourself systems.
The main cons for the use of these technologies are safety, regarding information accuracy and data protection. However, online communities, blogs and social media are unstoppable and will continue to be sources of support and information for people living with chronic conditions. Ideally, clinicians should be able to guide patients towards trustworthy online information sources. Some scientific societies have recognized this and have undertaken the responsibility of emitting consensus guidelines for correct practices when sharing or obtaining information about diabetes on social media.88
Conclusion
Diabetes technologies can be used to empower patients and improve their self-care. The opportunities for empowerment offered by diabetes technologies include: safety, support, self-efficacy, and comfort. Cost and coverage are the most frequently encountered barriers reported by both clinicians and patients. Specific training and diabetes education for patients and healthcare provider teams, as well as an individualized approach to prioritize the needs of patients is required for the optimal use of these technologies. Cost-effectiveness results from the use of diabetes technologies depend on the particular device and technology, the setting, the endpoints and methodologies used, but in general, an optimal use of technologies is required to achieve benefits and cost-effectiveness. The use of technologies by people with diabetes is an unstoppable phenomenon given the opportunities they offer for improved self-care.
Acknowledgments
VAA has revised the literature, written and edited this work.
Footnotes
Ethical Approval: Ethical approval was not required for this review.
Funding: The author received a public scholarship from Departament d’Economia i Coneixement de la Generalitat de Catalunya, Spain from 2013 to 2017. The author received funding for clinical research in 2013 from Roche Diabetes Care Spain SL.
Conflict of interest statement: The author declares that there is no conflict of interest.
ORCID iD: Valeria Alcántara-Aragón https://orcid.org/0000-0001-5107-9888
References
- 1. Stuckey HL, Mullan-Jensen CB, Reach G, et al. Personal accounts of the negative and adaptive psychosocial experiences of people with diabetes in the second diabetes attitudes, wishes and needs (DAWN2) study. Diabetes Care 2014; 37: 2466–2474. [DOI] [PubMed] [Google Scholar]
- 2. Fisher L, Hessler D, Polonsky W, et al. Diabetes distress in adults with type 1 diabetes: prevalence, incidence and change over time. J Diabetes Complications 2016; 30: 1123–1128. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Burridge LH, Foster MM, Donald M, et al. Making sense of change: patients’ views of diabetes and GP-led integrated diabetes care. Health Expect 2016; 19: 74–86. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Majeed W, Thabit H. Closed-loop insulin delivery: current status of diabetes technologies and future prospects. Expert Rev Med Devices 2018; 15: 579–590. [DOI] [PubMed] [Google Scholar]
- 5. Heinemann L, Freckmann G, Ehrmann D, et al. Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial. Lancet 2018; 391: 1367–1377. [DOI] [PubMed] [Google Scholar]
- 6. Naranjo D, Tanenbaum ML, Iturralde E, et al. Diabetes technology: uptake, outcomes, barriers, and the intersection with distress. J Diabetes Sci Technol 2016; 10: 852–858. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Barnard KD, Wysocki T, Ully V, et al. Closing the loop in adults, children and adolescents with suboptimally controlled type 1 diabetes under free living conditions: a psychosocial substudy. J Diabetes Sci Technol 2017; 11: 1080–1088. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Ziegler C, Liberman A, Nimri R, et al. Reduced worries of hypoglycaemia, high satisfaction, and increased perceived ease of use after experiencing four nights of MD-logic artificial pancreas at home (DREAM4). J Diabetes Res 2015; 2015: 590308. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Naranjo D, Suttiratana SC, Iturralde E, et al. What end users and stakeholders want from automated insulin delivery systems. Diabetes Care 2017; 40: 1453–1461. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Tanenbaum ML, Adams RN, Hanes SJ, et al. Optimal use of diabetes devices: clinician perspectives on barriers and adherence to device use. J Diabetes Sci Technol 2017; 11: 484–492. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Chase HP, Beck RW, Xing D, et al. Continuous glucose monitoring in youth with type 1 diabetes: 12-month follow-up of the juvenile diabetes research foundation continuous glucose monitoring randomized trial. Diabetes Technol Ther 2010; 12: 507–515. [DOI] [PubMed] [Google Scholar]
- 12. Bailey TS, Walsh J, Stone JY. Emerging technologies for diabetes care. Diabetes Technol Ther 2018; 20: S278–S284. [DOI] [PubMed] [Google Scholar]
- 13. Lawton J, Blackburn M, Allen J, et al. Patients’ and caregivers’ experiences of using continuous glucose monitoring to support diabetes self-management: qualitative study. BMC Endocr Disord. 20 February 2018; 18: 12. DOI: 10.1186/s12902-018-0239-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Human factors and usability engineering – guidance for medical devices including drug-device combination products, version 1. MHRA, 2017, 47. [Google Scholar]
- 15. James S, Perry L, Gallagher R, et al. Diabetes educators’ intended and reported use of common diabetes-related technologies: discrepancies and dissonance. J Diabetes Sci Technol 2016; 10: 1277–1286. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16. Yu S, Varughese B, Li Z, et al. Healthcare resource waste associated with patient nonadherence and early discontinuation of traditional continuous glucose monitoring in real-world settings: a multi-country analysis. Diabetes Tech Therapeut 2018; 20: 420–427. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Seidel D, Boggio Mesnil F, Caruso A. Reimbursement pathways for new diabetes technologies in Europe: top-down versus bottom-up. J Diabetes Sci Technol 2018; 193229681878917. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. For the T1D Exchange Clinic Network, the DPV Initiative, and the National Paediatric Diabetes Audit and the Royal College of Paediatrics and Child Health registries, Sherr JL, Hermann JM, et al. Use of insulin pump therapy in children and adolescents with type 1 diabetes and its impact on metabolic control: comparison of results from three large, transatlantic paediatric registries. Diabetologia 2016; 59: 87–91. [DOI] [PubMed] [Google Scholar]
- 19. Maguire T. Continuous monitoring of glucose for type 1 diabetes: a health technology assessment. Ont Health Technol Assess Ser 2018; 18: 1–160. [PMC free article] [PubMed] [Google Scholar]
- 20. Park C, Le QA. The effectiveness of continuous glucose monitoring in patients with type 2 diabetes: a systematic review of literature and meta-analysis. Diabetes Technol Ther 2018; 20: 613–621. [DOI] [PubMed] [Google Scholar]
- 21. McQueen RB, Ellis SL, Campbell JD, et al. Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes. Cost Eff Resour Alloc 2011; 9: 13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Borot S, Benhamou PY, Atlan C, et al. Practical implementation, education and interpretation guidelines for continuous glucose monitoring: a French position statement. Diabetes & Metabolism 2018; 44: 61–72. [DOI] [PubMed] [Google Scholar]
- 23. Klonoff DC. Telemedicine for diabetes: current and future trends. J Diabetes Sci Technol 2016; 10: 3–5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24. Inzucchi SE, Bergenstal RM, Buse JB, et al. Management of hyperglycemia in type 2 diabetes: a patient-centered approach: position Statement of the American Diabetes Association (ADA) and the European Association for the study of diabetes (EASD). Diabetes Care 2012; 35: 1364–1379. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25. Miller WR, Rollnick S. Motivational interviewing: helping people change. 3rd ed. New York, Guilford Press, 2013. [Google Scholar]
- 26. Bandura A. Health promotion by social cognitive means. Health Educ Behav 2004; 31: 143–164. [DOI] [PubMed] [Google Scholar]
- 27. Walsh J, Freckmann G, Roberts R, et al. Bolus calculator safety mandates a need for standards. J Diabetes Sci Technol 2017; 11: 3–6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28. Yamada E, Okada S, Nakajima Y, et al. Effect of carbohydrate counting using bolus calculators on glycemic control in type 1 diabetes patients during continuous subcutaneous insulin infusion. J Diabetes Investig 2017; 8: 496–500. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29. Parkin CG, Barnard K, Hinnen DA. Safe and efficacious use of automated bolus advisors in individuals treated with multiple daily insulin injection (MDI) therapy: lessons learned from the automated bolus advisor control and usability study (ABACUS). J Diabetes Sci Technol 2015; 9: 1138–1142. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Gonzalez C, Picón MJ, Tomé M, et al. Expert study: utility of an automated bolus advisor system in patients with type 1 diabetes treated with multiple daily injections of insulin—a crossover study. Diabetes Technol Ther 2016; 18: 282–287. [DOI] [PubMed] [Google Scholar]
- 31. Schmidt S, Nørgaard K. Bolus calculators. J Diabetes Sci Technol 2014; 8: 1035–1041. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32. Vallejo Mora M, del R, Carreira M, Anarte MT, et al. Bolus calculator reduces hypoglycemia in the short term and fear of hypoglycemia in the long term in subjects with type 1 diabetes (CBMDI Study). Diabetes Technol Ther 2017; 19: 402–409. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Pesl P, Herrero P, Reddy M, et al. An advanced bolus calculator for type 1 diabetes: system architecture and usability results. IEEE J Biomed Health Inform 2016; 20: 11–17. [DOI] [PubMed] [Google Scholar]
- 34. Walsh J, Roberts R, Heinemann L. Confusion regarding duration of insulin action: a potential source for major insulin dose errors by bolus calculators. J Diabetes Sci Technol 2014; 8: 170–178. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Klonoff DC, Kerr D. Smart pens will improve insulin therapy. J Diabetes Sci Technol 2018; 12: 551–553. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Danne T, Nimri R, Battelino T, et al. International consensus on use of continuous glucose monitoring. Diabetes Care 2017; 40: 1631–1640. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37. Heinemann L, Freckmann G, Ehrmann D, et al. Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial. Lancet 2018; 391: 1367–1377. [DOI] [PubMed] [Google Scholar]
- 38. Alcántara V, Cubero JM, Prados A, et al. Crisis comicial en paciente diabética. ¿Hipoglucemia o efecto secundario de la monitorización continua de glucosa? Endocrinología y Nutrición 2012; 59: 144–146. [DOI] [PubMed] [Google Scholar]
- 39. Wang X, Ioacara S, DeHennis A. Long-term home study on nocturnal hypoglycemic alarms using a new fully implantable continuous glucose monitoring system in type 1 diabetes. Diabetes Technol Ther 2015; 17: 780–786. [DOI] [PubMed] [Google Scholar]
- 40. Majeed W, Thabit H. Closed-loop insulin delivery: current status of diabetes technologies and future prospects. Expert Rev Med Devices 2018; 15: 579–590. [DOI] [PubMed] [Google Scholar]
- 41. Lee H, Hong YJ, Baik S, et al. Enzyme-based glucose sensor: from invasive to wearable device. Adv Healthc Mater 2018; 7: e1701150. [DOI] [PubMed] [Google Scholar]
- 42. Freckmann G, Link M, Westhoff A, et al. Prediction quality of glucose trend indicators in two continuous tissue glucose monitoring systems. Parts of these data were previously presented at the 53rd Annual Meeting of the European Association for the Study of Diabetes, September 11–15, 2017, Lisbon, Portugal Diabetes Tech Therapeut 2018; 20: 550–556. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43. Rayman G, Kröger J, Bolinder J. Could freeStyle Libre TM sensor glucose data support decisions for safe driving? Diabet Med 2018; 35: 491–494. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Ajjan RA, Cummings MH, Jennings P, et al. Accuracy of flash glucose monitoring and continuous glucose monitoring technologies: implications for clinical practice. Diab Vasc Dis Res 2018; 15: 175–184. [DOI] [PubMed] [Google Scholar]
- 45. Rigla M, Pons B, Rebasa P, et al. Human subcutaneous tissue response to glucose sensors: macrophages accumulation impact on sensor accuracy. Diabetes Technol Ther 2018; 20: 296–302. [DOI] [PubMed] [Google Scholar]
- 46. Seidel D, Boggio Mesnil F, Caruso A. Reimbursement pathways for new diabetes technologies in Europe: top-down versus bottom-up. J Diabetes Sci Technol 2018; 193229681878917. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47. Yu S, Varughese B, Li Z, et al. Healthcare resource waste associated with patient nonadherence and early discontinuation of traditional continuous glucose monitoring in real-world settings: a multicountry analysis. Diabetes Technol Ther 2018; 20: 420–427. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48. Giménez M, Díaz-Soto G, Andía V, et al. Documento de consenso SED-SEEP sobre el uso de la monitorización continua de la glucosa en España. Endocrinología, Diabetes y Nutrición 2018; 65: 24–28. [Google Scholar]
- 49. Wan W, Skandari MR, Minc A, et al. Cost-effectiveness of continuous glucose monitoring for adults with type 1 diabetes compared with self-monitoring of blood glucose: the DIAMOND randomized trial. Diabetes Care 2018; 41: 1227–1234. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50. Huang ES, O’Grady M, Basu A, et al. The cost-effectiveness of continuous glucose monitoring in type 1 diabetes. Diabetes Care 2010; 33: 1269–1274. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51. McQueen RB, Ellis SL, Campbell JD, et al. Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes. Cost Eff Resour Alloc 2011; 9: 13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52. Aleppo G, Ruedy KJ, Riddlesworth TD, et al. REPLACE-BG: a randomized trial comparing continuous glucose monitoring with and without routine blood glucose monitoring in adults with well-controlled type 1 diabetes. Diabetes Care 2017; 40: 538–545. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53. Aleppo G, Laffel LM, Ahmann AJ, et al. A practical approach to using trend arrows on the Dexcom G5 CGM system for the management of adults with diabetes. J Endocr Soc 2017; 1: 1445–1460. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54. Dunn TC, Xu Y, Hayter G, et al. Real-world flash glucose monitoring patterns and associations between self-monitoring frequency and glycaemic measures: a European analysis of over 60 million glucose tests. Diabetes Res Clin Pract 2018; 137: 37–46. [DOI] [PubMed] [Google Scholar]
- 55. Ólafsdóttir AF, Attvall S, Sandgren U, et al. A clinical trial of the accuracy and treatment experience of the flash glucose monitor freestyle libre in adults with type 1 diabetes. Diabetes Technol Ther 2017; 19: 164–172. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56. Campbell FM, Murphy NP, Stewart C, et al. Outcomes of using flash glucose monitoring technology by children and young people with type 1 diabetes in a single arm study. Pediatr Diabetes 2018; 19: 1294–1301. [DOI] [PubMed] [Google Scholar]
- 57. Scott EM, Bilous RW, Kautzky-Willer A. Accuracy, user acceptability, and safety evaluation for the freestyle libre flash glucose monitoring system when used by pregnant women with diabetes. Diabetes Technol Ther 2018; 20: 180–188. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58. Reddy M, Jugnee N, El Laboudi A, et al. A randomized controlled pilot study of continuous glucose monitoring and flash glucose monitoring in people with type 1 diabetes and impaired awareness of hypoglycaemia. Diabet Med 2018; 35: 483–490. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59. Haak T, Hanaire H, Ajjan R, et al. Use of flash glucose-sensing technology for 12 months as a replacement for blood glucose monitoring in insulin-treated type 2 diabetes. Diabetes Ther 2017; 8: 573–586. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60. Hellmund R, Weitgasser R, Blissett D. Cost calculation for a flash glucose monitoring system for UK adults with type 1 diabetes mellitus receiving intensive insulin treatment. Diabetes Res Clin Pract 2018; 138: 193–200. [DOI] [PubMed] [Google Scholar]
- 61. Kropff J, Choudhary P, Neupane S, et al. Accuracy and longevity of an implantable continuous glucose sensor in the PRECISE study: a 180-day, prospective, multicenter, pivotal trial. Diabetes Care 2017; 40: 63–68. [DOI] [PubMed] [Google Scholar]
- 62. Lorenz C, Sandoval W, Mortellaro M. Interference assessment of various endogenous and exogenous substances on the performance of the eversense long-term implantable continuous glucose monitoring system. Diabetes Technol Ther 2018; 20: 344–352. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63. Bergenstal RM, Ahmann AJ, Bailey T, et al. Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the ambulatory glucose profile. J Diabetes Sci Technol 2013; 7: 562–578. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64. Battelino T, Nimri R, Dovc K, et al. Prevention of hypoglycemia with predictive low glucose insulin suspension in children with type 1 diabetes: a randomized controlled trial. Diabetes Care 2017; 40: 764–770. [DOI] [PubMed] [Google Scholar]
- 65. Forlenza GP, Li Z, Buckingham BA, et al. Predictive low-glucose suspend reduces hypoglycemia in adults, adolescents, and children with type 1 diabetes in an at-home randomized crossover study: results of the PROLOG trial. Diabetes Care. Epub ahead of print 8 August 2018. DOI: 10.2337/dc18-0771. [DOI] [PubMed] [Google Scholar]
- 66. Garg SK. Expanding treatment options for improving health outcomes in type 1 diabetes. Diabetes Technol Ther 2017; 19: 549–551. [DOI] [PubMed] [Google Scholar]
- 67. Buckingham BA, Christiansen MP, Forlenza GP, et al. Performance of the omnipod personalized model predictive control algorithm with meal bolus challenges in adults with type 1 diabetes. Diabetes Technol Ther 2018; 20: 585–595. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68. Barnard KD, Wysocki T, Ully V, et al. Closing the loop in adults, children and adolescents with suboptimally controlled type 1 diabetes under free living conditions: a psychosocial substudy. J Diabetes Sci Technol 2017; 11: 1080–1088. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69. Ziegler C, Liberman A, Nimri R, et al. Reduced worries of hypoglycaemia, high satisfaction, and increased perceived ease of use after experiencing four nights of MD-logic artificial pancreas at home (DREAM4). J Diabetes Res 2015; 2015: 590308. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70. McAuley SA, de Bock MI, Sundararajan V, et al. Effect of 6 months of hybrid closed-loop insulin delivery in adults with type 1 diabetes: a randomised controlled trial protocol. BMJ Open 2018; 8: e020274 . [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71. Luley C, Blaik A, Reschke K, et al. Weight loss in obese patients with type 2 diabetes: Effects of telemonitoring plus a diet combination – The Active Body Control (ABC) program. Diabetes Res Clin Pract 2011; 91: 286–292. [DOI] [PubMed] [Google Scholar]
- 72. Esmatjes E, Jansà M, Roca D, et al. The efficiency of telemedicine to optimize metabolic control in patients with type 1 diabetes mellitus: Telemed study. Diabetes Technol Ther 2014; 16: 435–441. [DOI] [PubMed] [Google Scholar]
- 73. Liou JK, Soon MS, Chen CH, et al. Shared care combined with telecare improves glycemic control of diabetic patients in a rural underserved community. Telemed J E Health 2014; 20: 175–178. [DOI] [PubMed] [Google Scholar]
- 74. Daskivich LP, Vasquez C, Martinez C, et al. Implementation and evaluation of a large-scale teleretinal diabetic retinopathy screening program in the Los Angeles county department of health services. JAMA Intern Med 2017; 177: 642–649. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 75. Reid MW, Krishnan S, Berget C, et al. CoYoT1 clinic: home telemedicine increases young adult engagement in diabetes care. J Diabetes Sci Technol 2018; 20: 370–379. [DOI] [PubMed] [Google Scholar]
- 76. Accu-Chek at ATTD and Roche Diabetes Care Services. Roche Diabetes Care at ATTD 2018, https://www.accu-chek-congresses.com/attd/ (2017, accessed 1 September 2018).
- 77. Miller AS, Cafazzo JA, Seto E. A game plan: gamification design principles in mHealth applications for chronic disease management. Health Informatics J 2016; 22: 184–193. [DOI] [PubMed] [Google Scholar]
- 78. Hompesch M, Kalcher K, Debong F, et al. Significant improvement of blood glucose control in a high risk population of type 1 diabetes using a mobile health app – a retrospective observational study. Vienna, Austria: ProSciento, Inc. [Google Scholar]
- 79. Offringa R, Sheng T, Parks L, et al. Digital diabetes management application improves glycemic outcomes in people with type 1 and type 2 diabetes. J Diabetes Sci Technol 2018; 12: 701–708. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80. Osborn CY, van Ginkel JR, Marrero DG, et al. One drop | mobile on iPhone and Apple Watch: an evaluation of HbA1c improvement associated with tracking self-care. JMIR Mhealth Uhealth 2017; 5: e179. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81. Downing J, Bollyky J, Schneider J. Use of a connected glucose meter and certified diabetes educator coaching to decrease the likelihood of abnormal blood glucose excursions: the Livongo for diabetes program. J Med Internet Res 2017; 19: e234. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82. Pfützner A, Strobl S, Demircik F, et al. Evaluation of a new noninvasive glucose monitoring device by means of standardized meal experiments. J Diabetes Sci Technol 2018; 12: 1178–1183. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83. Bond K, Reese P, Weispfenning R. form Medtronic plc. Artificial intelligence-powered sugar.IQTM diabetes management app developed by medtronic and ibm watson health now commercially available. IBM News Room, June 22 2018.http://newsroom.ibm.com/announcements?item=122916 (accessed 1 September 2018).
- 84. Vasiloglou M, Mougiakakou S, Aubry E, et al. A comparative study on carbohydrate estimation: GoCARB vs. Dietitians. Nutrients 2018; 10: 741. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85. Vaala SE, Hood KK, Laffel L, et al. Use of commonly available technologies for diabetes information and self-management among adolescents with type 1 diabetes and their parents: a web-based survey study. Interact J Med Res 2015; 4: e24. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 86. Merolli M, Gray K, Martin-Sanchez F, et al. Patient-reported outcomes and therapeutic affordances of social media: findings from a global online survey of people with chronic pain. J Med Internet Res. January 2015; 17: e20. DOI: 10.2196/jmir.3915. ISSN 1438-8871 22 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 87. Lee JM, Newman MW, Gebremariam A, et al. Real-world use and self-reported health outcomes of a patient-designed do-it-yourself mobile technology system for diabetes: lessons for mobile health. Diabetes Technol Ther 2017; 19: 209–219. [DOI] [PubMed] [Google Scholar]
- 88. Bautista V, Royo D, Lledo A, et al. from Canal Diabetes. Diabetes F para la. Decálogo sobre el manejo de la diabetes en las redes sociales, 14 November 2015, http://www.fundaciondiabetes.org/general/material/97/decalogo-sobre-el-manejo-de-la-diabetes-en-las-redes-sociales (accessed 1 September 2018).