Skip to main content
International Journal of Molecular Sciences logoLink to International Journal of Molecular Sciences
. 2019 Feb 12;20(3):776. doi: 10.3390/ijms20030776

MRI Relaxometry for Quantitative Analysis of USPIO Uptake in Cerebral Small Vessel Disease

Michael J Thrippleton 1,2,, Gordon W Blair 1,2,, Maria C Valdes-Hernandez 1,2,3, Andreas Glatz 1,2, Scott I K Semple 2,4, Fergus Doubal 1, Alex Vesey 4, Ian Marshall 1,2, David E Newby 2,4, Joanna M Wardlaw 1,2,3,*
PMCID: PMC6387454  PMID: 30759756

Abstract

A protocol for evaluating ultrasmall superparamagnetic particles of iron oxide (USPIO) uptake and elimination in cerebral small vessel disease patients was developed and piloted. B1-insensitive R1 measurement was evaluated in vitro. Twelve participants with history of minor stroke were scanned at 3-T MRI including structural imaging, and R1 and R2* mapping. Participants were scanned (i) before and (ii) after USPIO (ferumoxytol) infusion, and again at (iii) 24–30 h and (iv) one month. Absolute and blood-normalised changes in R1 and R2* were measured in white matter (WM), deep grey matter (GM), white matter hyperintensity (WMH) and stroke lesion regions. R1 measurements were accurate across a wide range of values. R1 (p < 0.05) and R2* (p < 0.01) mapping detected increases in relaxation rate in all tissues immediately post-USPIO and at 24–30 h. R2* returned to baseline at one month. Blood-normalised R1 and R2* changes post-infusion and at 24–30 h were similar, and were greater in GM versus WM (p < 0.001). Narrower distributions were seen with R2* than for R1 mapping. R1 and R2* changes were correlated at 24–30 h (p < 0.01). MRI relaxometry permits quantitative evaluation of USPIO uptake; R2* appears to be more sensitive to USPIO than R1. Our data are explained by intravascular uptake alone, yielding estimates of cerebral blood volume, and did not support parenchymal uptake. Ferumoxytol appears to be eliminated at 1 month. The approach should be valuable in future studies to quantify both blood-pool USPIO and parenchymal uptake associated with inflammatory cells or blood-brain barrier leak.

Keywords: cerebral small vessel disease, MRI, ferumoxytol, USPIO, inflammation, relaxometry

1. Introduction

Cerebral small vessel disease (SVD) accounts for 20–25% of strokes and increases the risk of cognitive impairment, disability and dementia. The pathogenesis is poorly understood but several mechanisms are hypothesised to contribute, including inflammation [1], blood-brain barrier (BBB) leakage [2] and vessel stiffness [3]. Several magnetic resonance imaging (MRI) methods have been used to explore microstructural and microvascular properties in SVD, including those utilising intrinsic tissue contrast (e.g., diffusion tensor imaging to assess white matter integrity) [4], respiratory gas challenges (e.g., cerebrovascular reactivity) [5], and gadolinium contrast-based approaches (e.g., dynamic contrast-enhanced (DCE) MRI to quantify BBB permeability) [6]. As far as we are aware, no studies have employed ultrasmall superparamagnetic particles of iron oxide (USPIO) contrast agents to study SVD. These particles, which have T1, T2 and T2* shortening effects, have several benefits compared with gadolinium-based contrast agents: (i) a large T2* effect due to the superparamagnetic nature of the contrast agent, (ii) they may often be used in patients with renal failure, for whom gadolinium-based agents are contraindicated [7], (iii) slow rates of extravasation and elimination facilitate convenient MR angiography at high resolution and steady-state cerebral blood volume (CBV) measurement [8], and (iv) phagocytosis by macrophages, which concentrate in inflamed tissue, provides an imaging marker of inflammation [9], for example in abdominal aortic aneurysm [10] and myocardial infarction [11]. However, since inflammatory uptake typically occurs over a longer period than the MRI examination, multiple examinations are required and quantitative analysis based on signal changes is therefore impractical.

In this pilot study, we developed and evaluated an MRI relaxometry protocol for assessing USPIO (ferumoxytol) uptake in patients with cerebral SVD. We measured R2* using the three dimensional multiple-spoiled-gradient-echo technique. Volumetric mapping of R1 within a feasible scan time is challenging at 3T, where increased B1 inhomogeneity impairs the accuracy of the widely-used and widely-available variable flip angle method; we therefore adapted the DESPOT1-HIFI approach proposed by Deoni et al. so that small changes in R1 obtained across different examinations could be measured [12]. We first scanned a multi-compartment test object containing a range of R1 values to confirm the accuracy of R1 mapping. We then studied patients following recent minor ischaemic stroke, since SVD features are prevalent in such patients compared with the wider population [13,14]. Specifically, we aimed to (i) validate B1-insensitive R1 measurement against a reference-standard technique, (ii) determine whether R1 and R2* changes in the brain are detectable following USPIO infusion and at one day following infusion, (iii) determine whether residual USPIO is detectable one month after administration by obtaining an additional R2* measurement (R1 was not measured at this time point in order to reduce the burden on participants), and (iv) measure blood-normalised R1 and R2* changes in grey matter (GM), normal-appearing white matter (WM) and white matter hyperintensity (WMH) tissue regions in this patient group in order to estimate cerebral blood volume and test for potential extravascular or perivascular USPIO uptake due to inflammation or BBB leak. Blood R1 was measured in the superior sagittal sinus and used for normalisation of both R1 and R2* changes in tissue, since R2* changes in blood were spatially heterogeneous and inconsistent across patients.

2. Results

2.1. Compliance, Tolerability and Symptoms

R1 and R2* maps, and structural images were obtained successfully in all 12 patients (mean age 74.7 ± 6.3 years; Table 1). Scan 2 occurred on average 28 h (range: 26–30 h) after scan 1pre for all patients, while scan 3 took place an average of 31 days (range: 22–36 days) after scan 1pre. Values of R1 and ΔR1 for one patient at scan 1post were outliers and were excluded from analyses; no signs of protocol deviations or of unusual observations in relation to this participant were found in the study records or image header information.

Table 1.

Patient demographics.

Characteristic (N = 12)
Age (mean ± SD) 74.1 ± 6.7
Male 67% (8)
Prior Stroke or TIA 17% (2)
Diabetes 17% (2)
Hypertension 75% (9)
Hyperlipidaemia 58% (7)
Ischaemic Heart Disease 8% (1)
History of Smoking 50% (6)
Alcohol Intake (units per week, median and range) 9 (0–30)
NIHSS (median and range) 2 (1–4)
Modified Rankin Score Post Stroke (median and range) 1 (0–2)
Days Post-Stroke (median and range) 48 (31–276)
WMH Volume (mL) (median and range) 12.5 (3.2–46.9)

TIA: transient ischaemic attack; NIHSS: National Institutes of Health Stroke Scale; WMH: white matter hyperintensity.

2.2. In Vitro Accuracy of R1 Mapping

R1 measurements in a MRI phantom (test object) obtained using the variable flip angle approach were inaccurate compared with gold-standard inversion-recovery spin-echo measurements (absolute difference: 0.03–0.58 s−1; Figure 1a). The errors were largely explained by the spatial flip angle variation (measured using DESPOT1-HIFI), which was found to be greater than the nominal value in the five regions with lowest R1 and vice versa. DESPOT1-HIFI R1 measurements corresponded more closely to gold-standard measurements across the full range of values provided the equation of Deichmann et al. [15] was used to model the IR-sGRE signal (absolute difference: 0.01–0.23 s−1; Figure 1a). Results obtained using a simplified IR-sGRE signal model (absolute difference: 0.01–0.87 s−1; Figure 1a) were acceptable within the range of R1 found in GM and WM but were inaccurate at the highest R1 value, which is typical of blood magnetisation following USPIO administration. To explore this further, the signals predicted by both models and by the full mathematical description by Brix et al. were calculated as a function of R1 (Figure 1b), demonstrating substantial errors in the simplified model predictions at high R1 values. Patients’ measurements were therefore obtained using the DESPOT1-HIFI method with the Deichmann signal model.

Figure 1.

Figure 1

(a) Errors in the R1 measurements versus gold-standard inversion-recovery spin-echo (IRSE) values, measured in a phantom using DESPOT1-HIFI with the Deichmann signal model, an approximate signal model neglecting effects of the pulse train and using the variable flip angle method; (b) Calculated inversion-recovery prepared spoiled gradient echo (IR-sGRE) signal (assuming s0 = 100) for the acquisition parameters given in Table 5 using both the full mathematical description of Brix et al., the model by Deichmann et al. and the simplified model as described in the text. Note that the Deichmann prediction is almost identical to that of the Brix model and is consequently not visible.

2.3. Relaxation Rate Changes Following USPIO Administration

Example parametric maps are shown in Figure 2, illustrating the subtle R1 and R2* changes observed in patients. R1 increased relative to baseline in all regions at scan 1post and scan 2 (Table 2, Figure 3a; p < 0.05). R2* also increased in all regions at scan 1post and scan 2 (Table 2, Figure 3b; p < 0.01). There was a trend towards increasing R1 between scan 1post and scan 2 in all regions, but this was statistically significant only in blood (p < 0.01) and WMH (p < 0.05); for R2*, a significant further increase between scan 1post and scan 2 was seen in WM, GM, WMH (p < 0.001) and in stroke lesions (p < 0.05). Relaxation rates corresponding to each subject, region and time point are provided as supplementary material.

Figure 2.

Figure 2

(a) R1 maps for a single patient at three time points: pre-ultrasmall superparamagnetic particles of iron oxide (USPIO) (scan 1pre), immediately post-USPIO (scan 1post), and at 24–30 h post-USPIO (scan 2). The corresponding relative flip angle (i.e., k: the actual flip angle divided by the nominal value) map measured at baseline is shown on the right, illustrating both variation due to B1 inhomogeneity and the (axial) slab excitation profile; (b) R2* maps in the same patient, obtained at the same time points and at 1 month post-USPIO (scan 3); (c) Parametric maps in another patient (79 year old male, first visit 31 days post-infarct in the left basal ganglia). R1 is seen to increase visibly in the stroke lesion following USPIO administration. The corresponding change to R2* is more subtle in the stroke lesion, but a visible increase is seen in the neighbouring background tissue.

Table 2.

Mean (standard deviation) relaxation rate values for each region of interest (ROI), averaged over patients. Statistically significant changes relative to baseline are indicated by * (p < 0.05), ** (p < 0.01) and *** (p < 0.001).

ROI R1 (s−1) R2* (s−1)
Scan 1pre Scan 1post Scan 2 Scan 1pre Scan 1post Scan 2 Scan 3
blood 0.526 (0.036) 3.672 (0.629) *** 4.665 (1.140) *** - - - -
WM 1.090 (0.034) 1.123 (0.022) ** 1.129 (0.032) *** 19.3 (0.7) 22.1 (0.4) *** 23.0 (0.8) *** 19.3 (0.7)
GM 0.825 (0.036) 0.907 (0.022) *** 0.908 (0.041) *** 19.1 (1.3) 24.9 (1.5) *** 26.6 (2.2) *** 19.3 (1.0)
WMH 0.905 (0.075) 0.983 (0.061) * 0.967 (0.067) *** 16.5 (1.1) 19.7 (1.0) *** 20.5 (1.6) *** 16.6 (1.1)
SL 0.926 (0.108) 1.002 (0.116) * 0.989 (0.102) *** 19.0 (3.6) 21.4 (2.5) ** 23.9 (4.6) *** 19.3 (3.7)

WM: (normal-appearing) white matter, GM: grey matter, WMH: white matter hyperintensities, SL: stroke lesion.

Figure 3.

Figure 3

Median relaxation rates (a) R1 and (b) R2* for each participant and tissue region at scan 1pre (pre-USPIO), scan 1post (immediately post-USPIO), scan 2 (24–30 h post-USPIO) and scan 3 (1-month post-USPIO, R2* only). Abbreviations: WM: normal-appearing white matter, GM: grey matter, WMH: white matter hyperintensities, SL: stroke lesion.

The mean change in R2* at scan 3 (one month) was small (0.006–0.327 s−1) and was not statistically significant in any of the regions. There was no association between changes in the two relaxation rates ΔR1 and ΔR2* immediately following USPIO administration except in WMH (p < 0.05), but there was a strong association in all regions at 24–30 h (p < 0.01; Table 3, Figure 4).

Table 3.

Linear regression analysis of change in R1R1) versus change in R2* (ΔR2*) at scan 1post (immediately post-USPIO) and scan 2 (24–30 h post-USPIO). Changes are calculated relative to scan 1pre (pre-USPIO) values. Statistically significant associations are indicated by * (p < 0.05), ** (p < 0.01) and *** (p < 0.001).

ROI Scan 1post Scan 2
β0 (s−1) β1 R 2 β0 (s−1) β1 R 2
WM 2.6 14.2 0.18 2.5 33.4 0.61 **
GM 4.7 14.9 0.06 1.7 69.2 0.70 ***
WMH 2.1 18.7 0.75 * 2.4 25.3 0.73 ***
SL 1.8 47.2 0.34 1.3 56.9 0.64 **

β0: intercept, β1: slope, WM: normal-appearing white matter, GM: grey matter, WMH: white matter hyperintensities, SL: stroke lesion.

Figure 4.

Figure 4

Change in R2* (ΔR2*) versus change in R1R1) at scan 1post (immediately post-USPIO; circles) and at scan 2 (24–30 h post-USPIO; crosses). Each data point represents the change in relaxation rate for a subject relative to the value measured at scan 1 (pre-USPIO). Dotted lines show the best fit to the data at scan 2; full linear regression results are given in Table 3.

2.4. Blood-Normalised Relaxation Rate Changes

The blood-normalised relaxation rate changes ∆R1,norm and ΔR2,norm* (Table 4, Figure 5) did not change between scan 1post and scan 2 in any of the tissue regions—in other words, the tissue relaxation rate changes over this period are accounted for by the changes in capillary USPIO concentration following infusion of the final two-thirds dose, and elimination and redistribution of the contrast agent. Values were greater in GM than in WM for both measures and time points (p < 0.001). ∆R1,norm at scan 2 was also greater in WMH and SL versus WM (p < 0.05); there were no other significant differences between tissues. In general, a narrower distribution of values (expressed as the coefficient of variation; Table 4) was seen for ΔR2,norm* compared with ∆R1,norm.

Table 4.

Normalised relaxation rate changes for each ROI, averaged over patients. Coefficients of variation (%) are shown in parenthesis. Statistically significant differences compared with WM are indicated by * (p < 0.05), ** (p < 0.01) and *** (p < 0.001).

ROI R1,norm ΔR2,norm*
Scan 1post Scan 2 Scan 1post Scan 2
WM 0.0084 (45) 0.0087 (43) 0.97 (16) 0.93 (14)
GM 0.0239 (21) *** 0.0204 (16) *** 1.86 (11) *** 1.85 (14) ***
WMH 0.0153 (68) 0.0148 (50) * 0.96 (22) 0.97 (17)
SL 0.0125 (34) 0.0151 (38) * 1.17 (26) 1.21 (41)

WM: normal-appearing white matter, GM: grey matter, WMH: white matter hyperintensities, SL: stroke lesion.

Figure 5.

Figure 5

Blood-normalised relaxation rate changes (a) ∆R1,norm and (b) ΔR2,norm* at scan 1post (immediately post-USPIO) and scan 2 (24–30 h post-USPIO). Changes are relative to baseline values measured at scan 1pre (pre-USPIO) and are normalised to corresponding R1 changes in blood. Values at scan 1post are approximately equivalent (∆R1,norm) or proportional (ΔR2,norm* ) to cerebral blood volume fraction, while values at scan 2 are potentially influenced by additional parenchymal USPIO uptake. Abbreviations: WM: normal-appearing white matter, GM: grey matter, WMH: white matter hyperintensities, SL: stroke lesion.

3. Discussion

In this study we administered USPIO and performed R1 and R2* mapping in patients with SVD. The USPIO were tolerated, and importantly, we found no evidence of retention at one month. We established a protocol for assessing contrast uptake, including R1 mapping in the presence of the substantial B1 inhomogeneity seen at 3T and validated this in vitro. Using relaxometry, we were able to detect changes in both normal and diseased tissues immediately after USPIO administration at one third of the standard dose, and at one day following administration of the full dose. Blood-normalised changes in the relaxation rates in WM and GM regions were consistent with expected differences in cerebral blood volume, and did not change further at 24–30 h, which implies that no detectable parenchymal uptake occurred on this timescale. Changes in R1 and R2* were strongly correlated at 24–30 h; the weak association immediately post-contrast is likely due to fewer subjects receiving scan 1post (n = 8). Narrower distributions were seen for R2*-compared with R1-derived quantities, suggesting that the former may be a more sensitive marker of uptake.

Few previous studies have employed quantitative MRI to assess USPIO uptake in the brain, and we are unaware of any such application in cerebral small vessel disease patients. A small number of studies have administered USPIO in stroke patients, with observations of signal change, mainly on T1w images, that can be cautiously ascribed to inflammatory uptake in some stroke lesions within 1–2 weeks following acute ischaemic stroke [16,17,18,19]. A key advantage of using quantitative relaxometry, as here, is that uptake occurring over a longer time period can be measured; approaches based on changes in signal intensity are restricted to qualitative interpretation or to measuring uptake during the examination (as in DCE and dynamic susceptibility contrast MRI). By performing quantitative relaxometry including blood pool measurements, we were also able to determine whether the observed changes could be explained by intra-vascular (as opposed to parenchymal) USPIO uptake.

The approach presented in this paper relies on accurate volumetric measurement of R1 and R2*. Through selection of an appropriate acquisition strategy and careful signal modelling, we were able to measure inter-examination R1 changes, obtaining GM, WM and venous blood R1 values similar to those reported in the literature [20,21,22]. While the alternative variable flip angle (VFA) method is faster than DESPOT1-HIFI (since the additional IR-sGRE scans are relatively time-consuming), the former approach yields parameter maps that are strongly affected by spatial variation in the flip angle, which can be substantial at 3T and/or when slab-selective excitation pulses are used. Our phantom measurements confirmed the accuracy of DESPOT1-HIFI across a range of R1 provided appropriate signal models are used. Alternatively, it is possible to reduce the scan time by combining VFA acquisition with a technique that directly maps the flip angle, such as actual flip angle imaging (AFI) [23], but reliable flip angle mapping sequences are not widely available on commercial MRI scanners. R2* values are necessarily protocol-dependent and are affected by macroscopic B0 field inhomogeneities, and there is no accepted gold-standard method. However, the values measured in thalamus at baseline were similar to those reported previously in volunteers [24,25].

As expected, both R1 and R2* increased following USPIO administration. At one-month post-infusion, R2* had returned to baseline with no statistically significant changes detected. The average one-month changes in R2* corresponded to 0.2% (WM), 3.4% (GM), 1.2% (WMH) and 6.7% (SL) of the average changes measured at 24–30 h, implying elimination or near-elimination of ferumoxytol from the regions measured on this timescale.

Although R1 and R2* increases were detected in the brain tissue of all patients following USPIO administration, such measurements do not distinguish between USPIO in the blood pool from uptake in parenchyma. We therefore obtained additional measurements immediately after infusing a third of the full dose, at which point it is reasonably assumed that any uptake is intravascular and that the normalised relaxation rate changes, ∆R1,norm and ΔR2,norm*, are respectively equivalent or proportional to the cerebral blood volume fraction. ∆R1,norm measurements were consistent with plasma volume fraction (vp) measurements obtained in a similar patient group by DCE-MRI [6], and were greater in GM than in WM as expected. A similar pattern was seen for ΔR2,norm* measurements but there was no significant difference between WM and WMH values. Varallyay et al. used changes in T2*w signal intensity to assess relative CBV in patients with a variety of brain pathologies [8]. The approach described here extends this by measuring both R1 and R2*, and by normalising for blood-pool USPIO concentration, thereby enabling between as well as within-subject comparison.

Neither normalised relaxation rate changed significantly at 24–30 h following USPIO infusion. This suggests that there was no detectable parenchymal uptake—for example, due to accumulation of inflammatory cells or BBB leak—and that the signal changes observed are explained by the blood-pool uptake alone. In the event of parenchymal uptake occurring, there would likely be increased ∆R1,norm and ΔR2,norm* at 24–30 h. However, it is important to note that our sample size was small and that any generalised chronic neuroinflammation in SVD is likely to be subtle compared with that found in some diseases of the large arteries. Larger studies, ideally with histological or biochemical validation, are required to draw biological conclusions. Finally, we observed a strong linear association between, ∆R1,norm and ΔR2* at 24–30 h, suggesting that either quantity can be used to assess uptake.

Advantages of our work include the use of two quantitative relaxometry methods, additional post-contrast measurement to differentiate blood-pool and parenchymal USPIO uptake, and a final measurement to confirm elimination of ferumoxytol from the brain. Our R1 mapping protocol was validated in vitro and is resistant to B1 inhomogeneity. In contrast to acute ischaemic stroke, where inflammation may be directly visualised in the acute and sub-acute phases, chronic inflammation in SVD is likely to be more subtle and diffuse. It is therefore important to establish sensitive methods such as these for detecting changes that may not be radiologically visible. We recruited patients with past minor stroke including lacunar stroke since these subjects typically have a higher burden of small vessel disease features and a small index infarct, which can easily be separated from the other tissues of interest. Patients were scanned weeks or months following the index stroke, which also minimised the effect of any acute stroke changes on the background brain condition. The main limitation of this pilot study is the sample size, which precludes firm biological inferences.

Our data suggest that future studies of SVD (and other pathologies) using USPIO contrast agents would benefit from obtaining quantitative relaxation rate maps including immediately post-infusion to differentiate intravascular and parenchymal uptake. With regard to R1 versus R2*-based approaches, there are theoretical grounds for preferring an R1-based technique. First, the concentration dependence is simpler to model compared with R2*, subject to some of the standard assumptions implicit in DCE-MRI analysis (e.g., fast water exchange regime). Second, it is more straightforward to measure R1 than R2* in blood vessels. However, the tissue R1 changes observed in this study were subtle and had wider distributions compared with corresponding R2* changes. This is partly due to the combined intravascular and extravascular effects of blood-pool contrast in R2* sequences, which leads to greater sensitivity in fMRI and perfusion imaging applications, and the superparamagetic nature of USPIO particles. A second challenge is the optimisation of R1 mapping for the wide range of values observed following USPIO administration. In future studies, it may be expedient to increase the precision of R1 measurement (for example by sacrificing spatial resolution) or to focus on R2* measurement where time is limited. For the latter approach, it is nevertheless useful to obtain R1 in blood for normalisation, which could be achieved more rapidly using a single-slice technique in place of a whole-brain measurement protocol [22]. A caveat is that while parenchymal uptake is expected to increase R1, the effect on R2* is more difficult to determine due to a more complex dependence on concentration, distribution and geometry [26,27]. Future studies should also assess CBV and parenchymal uptake in relation to small vessel disease severity, including WMH and enlarged perivascular space burdens. In conclusion, our work advances the methodology for probing the neurovasculature in SVD and for quantitatively assessing uptake of USPIO, paving the way for further use of these contrast agents in cerebral small vessel disease research and in other pathologies.

4. Materials and Methods

4.1. Participants

Twelve patients were recruited with a history of non-disabling minor ischaemic stroke occurring a minimum of one month previously. Patients were recruited from the regional clinical stroke service as described previously [6,28], and from our register of patients with a clinical diagnosis of minor non-disabling ischaemic stroke in the past five years. “Non-disabling” was defined as not requiring assistance in activities of daily living (modified Rankin score ≤ 3). We included those with diabetes mellitus, hypertension and other vascular risk factors as long as these were well-controlled. We excluded patients with unstable diabetes, chronic kidney disease with estimated glomerular filtration rate < 30, other neurological disorders, or other life threatening medical conditions. We also excluded patients unable to give consent, with contraindications to MRI, and who had haemorrhagic stroke (but not haemorrhagic transformation of an infarct). The study was conducted following Research Ethics Committee approval (South East Scotland Research Ethics Committee 01, reference 14/SS/1081, 27 November 2014) and according to the principles expressed in the Declaration of Helsinki. All subjects gave written informed consent.

4.2. MRI and USPIO Administration

4.2.1. Patient Study

Participants were scanned using a 3-T Siemens Magnetom Verio MRI scanner with a 12-channel receive-only head coil (Siemens Healthcare, Erlangen, Germany). Scans took place at baseline (“scan 1pre”), which was immediately followed by USPIO (ferumoxytol; 4.0 mg/kg) infusion, at 24–30 h following infusion (“scan 2”) and at four weeks following infusion (“scan 3”). Eight of the patients were scanned additionally immediately after 1/3 of the total USPIO dose had been administered (“scan 1post”), with the remainder of the dose administered immediately after the scan. USPIO was administered outside of the scanner and was made up using a vial of ferumoxytol (30 mg/mL) diluted in up to 100 mL of sterile 0.9% sodium chloride to achieve a final concentration for infusion of 2–8 mg/mL, as recommended by the manufacturer. All participants received a final dose of 4.0 mg/kg, infused via a venous cannula sited in the participant’s forearm over at least 15 min with participants in a reclined or semi-recumbent position. A saline flush was administered following the infusion. Blood pressure was monitored and a physician was present at the time of administration and for at least 30 min afterwards to monitor the patient and treat any reactions.

Structural imaging consisted of T1w, T2w, GRE and T2-weighted FLAIR acquisitions. R1 and flip angle were measured using the DESPOT1-HIFI method [12] at scans 1pre, 1post and 2, consisting of two 3D inversion-recovery prepared spoiled gradient echo sequences (IR-sGRE) and three 3D spoiled gradient echo sequences (sGRE) with different flip angles. R2* was measured using a 3D multi-echo spoiled gradient echo sequence (ME-sGRE) at all four scans. MRI sequence parameters are provided in Table 5.

Table 5.

MRI acquisition parameters.

Scan Sequence TR (ms) TE (ms) FA (°) TI (ms) FOV (mm) Acquisition Matrix Slices × Thickness (mm) GRAPPA Factor Time (m:ss) Other
FLAIR Axial 2D PROPELLER 9100 125 130 - 240 256 48 × 3 - 4:53 -
ME-sGRE Axial 3D multi-echo spoiled gradient echo 50 4.6
8.5
14.0
19.5
25.0
30.5
36.0
41.5
15 - 240 × 240 256 (AP) × 192 (LR) 72 × 2 2 7:08 11.1% slice oversampling
DESPOT1-HIFI Axial 3D IR-sGRE 1190 2.3 5 1000 240 × 240 256 (AP) × 192 (LR) 72 × 2 - 3:50 11.1% slice oversampling; echo-spacing = 4.5 ms for IR-sGRE
Axial 3D IR-sGRE 1 632 2.3 5 450 2:03
Axial 3D sGRE 5.7 2.5 12 - 1:29
Axial 3D sGRE 5.7 2.5 5 - 1:29
Axial 3D sGRE 5.7 2.5 3 - 1:29
GRE Axial 3D gradient echo 40 20 15 - 240 × 240 320 (AP) × 256 (LR) 48 × 3 2 5:35 25.0% slice oversampling
T1w Sagittal IR-sGRE 2300 2.98 9 1100 256 × 256 256 × 256 208 × 1 2 5:21 23.1% slice oversampling
T2w Axial 2D PROPELLER 11,400 120 90 - 240 384 48 × 3 - 4:24 -

1 TR/TI = 832/650 ms for subjects 1 to 6; TR: repetition time; TE: echo time; FA: flip angle; TI: inversion time; FOV: field of view; AP: anterior/posterior; LR: left/right.

4.2.2. Phantom Validation

To verify the accuracy of the DESPOT1-HIFI protocol for a range of R1 values, we scanned a multi-compartment custom MRI phantom with a range of R1 [29]. This phantom consisted of nine sealed 10 mL syringes containing 0.05, 0.07, … and 0.21 mM MnCl2 in distilled water. The phantom container was filled with 1.5 g/L CuSO4 and 3.6 g/L NaCl solution to increase the coil loading, reduce susceptibility artefacts around the syringes and to provide a compartment with short T1 to mimic longitudinal relaxation in blood vessels following contrast injection [29]. Gold-standard measurements were obtained using a single-slice inversion-recovery spin-echo pulse sequence (TR/TE/TI = 1550/11/[30, 330, 730, 1130, 1530] ms). Since there is no accepted reference method for measuring R2* and the multi-echo spoiled gradient echo sequence is regarded as the standard method, we did not evaluate this sequence in vitro; however, phantom experiments can be used to evaluate repeatability, reproducibility and relaxivity properties [30].

4.3. Image Processing and Analysis

4.3.1. R1 Mapping

To generate R1 parametric maps (Figure 1a), the signals of the sGRE and IR-sGRE scans were corrected for intensity scaling imposed by the scanner. To account for motion between the scans, all were co-registered to the first volume using rigid body registration (FSL FLIRT [31]). Reference [12] recommends modelling of the IR-sGRE signal under the assumption that the readout pulse trains do not influence the recovery of longitudinal magnetisation; for IR-sGRE with perfect inversion, this assumption leads to the following approximation for the steady-state signal:

SIRsGRE=S012eR1TIeff+eR1TR1+eR1TRsinκβ (1)

where s0 represents the maximum possible signal, TIeff is the effective inversion time (i.e., the time between the inversion pulse and the excitation pulse for acquisition of the central k-space line), β is the flip angle corresponding to pulses in the readout train and k is the ratio of actual and nominal flip angles. To test the validity of this approximation, phantom data was modelled using both Equation (1) above and using the signal model expressed by Equation (13) in the article by Deichmann et al. [15], which does not make this assumption and which very closely approximates the complete pulse-by-pulse description derived by Brix et al. [32] The following additional characteristics of the IR-sGRE sequence implementation were taken into consideration: (i) the inversion pulse is non-selective and B1-insensitive, therefore complete inversion was assumed, and (ii) all k-space lines in the slice direction were sampled linearly in a single pulse train, thus the signal magnitude was calculated at the midpoint of the pulse train. Steady-state sGRE signals were modelled using the following well-known equation:

SsGRE=S01eR1TR1eR1TRcosκβsinκβ (2)

where T2* decay is assumed to be negligible at the short echo times used. s0, R1 and k were determined using in-house Matlab code (https://github.com/mjt320/HIFI) incorporating the Matlab lsqcurvefit function (MathWorks, Natick, MA, USA) to minimise the sum-of-square differences between the measured and predicted signals for each voxel. All three parameters were constrained to be positive. Additionally, R1 maps were obtained by fitting the sGRE phantom images alone with k fixed as unity in order to assess the accuracy of the widely-used variable flip angle technique.

4.3.2. R2* Mapping

To generate R2* maps (Figure 1b), multi-echo data was fit as described above using in-house Matlab code (https://github.com/mjt320/T2Star) but without constraints and using the signal model si=sTE=0eR2*TEi, where si and TEi are the signal and echo time for echo i, respectively, and sTE=0 is the steady-state signal at zero echo time. To avoid fitting low SNR voxels and to reduce bias due to the noise “floor” at long TE, voxels and individual data points with intensities close to the noise level were excluded from the fitting using empirically determined thresholds.

4.3.3. Structural Image Processing

Structural MR images were linearly co-registered to the gradient echo (GRE) image obtained at scan 1pre using a two-step rigid-body registration (FSL FLIRT [31]). The brain was extracted automatically using FSL BET2 [33] with an empirically-determined weighted average of the T2-weighted (T2w) and GRE images as input, after correcting both images for the effects of coil sensitivity inhomogeneities and linearly normalising their intensities [34]. The intracranial volume mask was refined by nullifying voxels with standard intensity scores below −1.2 in the GRE image and filling any “holes” in the resultant mask.

GM regions of interest (ROIs) representative of the deep grey matter were manually drawn as circular regions within the left and right thalamus on slices containing these structures, carefully avoiding tissue boundaries, lesions and vessels.

WM and WMH segmentation masks were obtained automatically using multispectral data fusion and a two-step Gaussian clustering followed by the computation of the Bayesian conditional probability for each cluster [35]. The first clusterisation operated on a four-dimensional array (three spatial dimensions plus sequence) formed by the combination of the brain-extracted T1w, T2w and FLAIR images, and generated likelihood maps of pure cerebrospinal fluid (CSF), normal-appearing white matter and a mixed tissue class containing features with high T2w and low T1w signal, including GM, WMH, SL and perivascular spaces. Deep GM voxels were removed from this map using a pipeline [36] that employs FMRIB Software Library tools and a cohort-relevant template; cortical GM was also removed via non-linear registration (NiftyReg, https://sourceforge.net/projects/niftyreg/) of a white matter template (http://datashare.is.ed.ac.uk/handle/10283) to subject space. A second clusterisation using GRE and FLAIR images was used to extract the FLAIR hyperintensities (i.e., SL and WMH) from any remaining elements of the mixed tissue class. Manual editing was then used to separate SL from WMH, guided by radiological reports. Likelihood maps were thresholded empirically to generate binary masks containing pure tissues with minimal contamination and were eroded to further reduce partial volume effects and the effects of any misregistration. Example masks and ROIs are shown in Figure 6.

Figure 6.

Figure 6

Regions of interest overlaid on the first image of the DESPOT1-HIFI series prior to USPIO infusion. Regions and segmentation masks shown are the manually drawn thalamus ROI (red), normal-appearing white matter (green), white matter hyperintensities (yellow) and the manually drawn stroke lesion ROI (blue).

4.3.4. Quantitative Image Processing

R1 and R2* maps were spatially co-registered to the first time point using NiftyReg (non-linear transformation) and using the first image acquired for R1 and the first echo image of the R2* scan. To obtain R1 values in blood, regions were manually drawn within the superior sagittal sinus on three neighbouring slices, located centrally within the slab. Other ROIs were transformed into the parameter map space and used to sample R1 and R2* values. Median values for each patient and ROI were used in further analyses.

To account for inter-patient and inter-visit variation in blood-pool USPIO concentration, the normalised change in R1 was calculated at each post-USPIO time point as ∆R1,norm = ∆R1/∆R1,blood, where Δ indicates the change relative to baseline (i.e., scan 1pre). Assuming a linear relationship between R1 and USPIO concentration, and assuming that USPIO is restricted to the blood pool immediately after infusion, this quantity approximates the cerebral blood volume fraction (CBV).

The normalised R2* change was also calculated. However, R2* values and changes in the superior sagittal sinus were spatially heterogeneous and inconsistent across patients, presumably due to the possibly complex [37], and to our knowledge, unknown dependence of R2* on venous USPIO concentration, vessel morphology, vessel orientation and location within the vessel [38]; therefore, blood R1 values were used for normalisation and the ratio ΔR2,norm* = ΔR2*/∆R1,blood was calculated, which is expected to be approximately proportional to the CBV immediately after infusion.

4.4. Statistics

Differences in relaxation rate between different time points or tissues were assessed using the two-sided paired t-test. Associations between R1 and R2* changes were explored using linear regression and Pearson’s correlation coefficient. A significance threshold of p < 0.05 was used.

Acknowledgments

We acknowledge radiology and radiography staff at the University of Edinburgh, Craig Buckley and Radhouene Neji (Siemens Healthcare) for advice regarding R1 relaxometry, and K. Shuler for providing expert research support.

Abbreviations

USPIO ultrasmall superparamagnetic particles of iron oxide
GM grey matter
WM white matter
WMH white matter hyperintensities
CBV cerebral blood volume
BBB blood-brain barrier
SL stroke lesion
ROI region of interest
IR-sGRE inversion-recovery prepared spoiled gradient echo
sGRE spoiled gradient echo
MRI magnetic resonance imaging

Supplementary Materials

The following are available online at http://www.mdpi.com/1422-0067/20/3/776/s1.

Author Contributions

Conceptualization, M.J.T., M.C.V.-H., S.I.K.S., F.D., A.V., I.M., D.E.N., J.M.W.; methodology, M.J.T., G.W.B., M.C.V.-H., A.G., S.I.K.S., F.D., A.V., J.M.W.; software, M.J.T., M.C.V.-H.; validation, M.J.T., M.C.V.-H., A.G.; formal analysis, M.J.T., G.W.B., M.C.V.-H.; investigation, M.J.T., G.W.B., M.C.V.-H., S.I.K.S., F.D., J.M.W.; resources, D.E.N., J.M.W.; data curation, M.J.T., G.W.B., M.C.V.-H.; writing—original draft preparation, M.J.T., M.C.V.-H., J.M.W.; writing—review and editing, M.J.T., G.W.B., M.C.V.-H., S.I.K.S., F.D., A.V., I.M., D.E.N., J.M.W.; visualisation, M.J.T.; supervision, F.D., J.M.W.; project administration, J.M.W., G.W.B.; funding acquisition, M.J.T., M.C.V.-H., S.I.K.S., F.D., A.V., I.M., D.E.N., J.M.W.

Funding

The study was funded by the Wellcome Trust—University of Edinburgh Institutional Strategic Support Fund, the University of Edinburgh Centre of Cognitive Ageing and Cognitive Epidemiology (G0700704/84698), Alzheimer’s Society Ref: 252 (AS-PG-14-033), European Union Horizon 2020 (project No 666881, ‘SVDs@Target’), the Row Fogo Charitable Trust (Grant no. BRO-D.FID3668413), The Fondation Leducq (16 CVD 05) and the UK Dementia Research Institute (Wardlaw Programme). We acknowledge the following for additional support associated with this study: 3T imaging was performed at the Edinburgh Imaging Facility at the Queen’s Medical Research Institute, part of Edinburgh Clinical Research Facility and the SINAPSE (Scottish Imaging Network: A Platform for Scientific Excellence) collaboration, funded by the Scottish Funding Council and the Chief Scientist Office of Scotland; MJT acknowledges financial support from the NHS Lothian Research and Development Office; GWB acknowledges the Stroke Association Princess Margaret Research Development Fellowship, Alzheimer Society (AS-PG-14-033) and EU Horizon 2020 (project No 666881, ‘SVDs@Target’) funding. FD is supported by a Garfield Weston Foundation Stroke Association Senior Clinical Lectureship and a NHS Research Scotland (NRS) fellowship from the Chief Scientist Office (Scotland). DEN is supported by the British Heart Foundation (CH/09/002, RE/13/3/30183, RM/13/2/30158) and is the recipient of a Wellcome Trust Senior Investigator Award (WT103782AIA).

Conflicts of Interest

The authors have no conflict of interest to declare.

References

  • 1.Aribisala B.S., Wiseman S., Morris Z., Valdes-Hernandez M.C., Royle N.A., Maniega S.M., Gow A.J., Corley J., Bastin M.E., Starr J., et al. Circulating inflammatory markers are associated with magnetic resonance imaging-visible perivascular spaces but not directly with white matter hyperintensities. Stroke. 2014;45:605–607. doi: 10.1161/STROKEAHA.113.004059. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Wardlaw J.M., Makin S.J., Hernandez M.C.V., Armitage P.A., Heye A.K., Chappell F.M., Munoz-Maniega S., Sakka E., Shuler K., Dennis M.S., et al. Blood-brain barrier failure as a core mechanism in cerebral small vessel disease and dementia: Evidence from a cohort study. Alzheimers Dement. 2017;13:634–643. doi: 10.1016/j.jalz.2016.09.006. [DOI] [Google Scholar]
  • 3.Wardlaw J., Smith C., Dichgans M. Microbleeds in cerebral small vessel disease—Authors’ reply. Lancet Neurol. 2013;12:736–737. doi: 10.1016/S1474-4422(13)70152-2. [DOI] [PubMed] [Google Scholar]
  • 4.Munoz Maniega S., Chappell F.M., Valdes Hernandez M.C., Armitage P.A., Makin S.D., Heye A.K., Thrippleton M.J., Sakka E., Shuler K., Dennis M.S., et al. Integrity of normal-appearing white matter: Influence of age, visible lesion burden and hypertension in patients with small-vessel disease. J. Cereb. Blood Flow Metab. 2017;37:644–656. doi: 10.1177/0271678X16635657. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Thrippleton M.J., Shi Y.L., Blair G., Hamilton I., Waiter G., Schwarzbauer C., Pernet C., Andrews P.J.D., Marshall I., Doubal F., et al. Cerebrovascular reactivity measurement in cerebral small vessel disease: Rationale and reproducibility of a protocol for MRI acquisition and image processing. Int. J. Stroke. 2018;13:195–206. doi: 10.1177/1747493017730740. [DOI] [PubMed] [Google Scholar]
  • 6.Heye A.K., Thrippleton M.J., Armitage P.A., Valdes Hernandez Mdel C., Makin S.D., Glatz A., Sakka E., Wardlaw J.M. Tracer kinetic modelling for DCE-MRI quantification of subtle blood-brain barrier permeability. NeuroImage. 2016;125:446–455. doi: 10.1016/j.neuroimage.2015.10.018. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Neuwelt E.A., Hamilton B.E., Varallyay C.G., Rooney W.R., Edelman R.D., Jacobs P.M., Watnick S.G. Ultrasmall superparamagnetic iron oxides (USPIOs): A future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)? Kidney Int. 2009;75:465–474. doi: 10.1038/ki.2008.496. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Varallyay C.G., Nesbit E., Fu R., Gahramanov S., Moloney B., Earl E., Muldoon L.L., Li X., Rooney W.D., Neuwelt E.A. High-resolution steady-state cerebral blood volume maps in patients with central nervous system neoplasms using ferumoxytol, a superparamagnetic iron oxide nanoparticle. J. Cereb. Blood Flow Metab. 2013;33:780–786. doi: 10.1038/jcbfm.2013.36. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Weinstein J.S., Varallyay C.G., Dosa E., Gahramanov S., Hamilton B., Rooney W.D., Muldoon L.L., Neuwelt E.A. Superparamagnetic iron oxide nanoparticles: Diagnostic magnetic resonance imaging and potential therapeutic applications in neurooncology and central nervous system inflammatory pathologies, a review. J. Cereb. Blood Flow Metab. 2010;30:15–35. doi: 10.1038/jcbfm.2009.192. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.MA3RS Study Investigators Aortic Wall Inflammation Predicts Abdominal Aortic Aneurysm Expansion, Rupture, and Need for Surgical Repair. Circulation. 2017;136:787–797. doi: 10.1161/CIRCULATIONAHA.117.028433. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Stirrat C.G., Alam S.R., MacGillivray T.J., Gray C.D., Dweck M.R., Raftis J., Jenkins W.S., Wallace W.A., Pessotto R., Lim K.H., et al. Ferumoxytol-enhanced magnetic resonance imaging assessing inflammation after myocardial infarction. Heart. 2017;103:1528–1535. doi: 10.1136/heartjnl-2016-311018. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Deoni S.C. High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI) J. Magn. Reson. Imaging. 2007;26:1106–1111. doi: 10.1002/jmri.21130. [DOI] [PubMed] [Google Scholar]
  • 13.Rost N.S., Rahman R.M., Biffi A., Smith E.E., Kanakis A., Fitzpatrick K., Lima F., Worrall B.B., Meschia J.F., Brown R.D., Jr., et al. White matter hyperintensity volume is increased in small vessel stroke subtypes. Neurology. 2010;75:1670–1677. doi: 10.1212/WNL.0b013e3181fc279a. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Staals J., Makin S.D., Doubal F.N., Dennis M.S., Wardlaw J.M. Stroke subtype, vascular risk factors, and total MRI brain small-vessel disease burden. Neurology. 2014;83:1228–1234. doi: 10.1212/WNL.0000000000000837. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Deichmann R., Good C.D., Josephs O., Ashburner J., Turner R. Optimization of 3-D MP-RAGE sequences for structural brain imaging. NeuroImage. 2000;12:112–127. doi: 10.1006/nimg.2000.0601. [DOI] [PubMed] [Google Scholar]
  • 16.Cho T.H., Nighoghossian N., Wiart M., Desestret V., Cakmak S., Berthezene Y., Derex L., Louis-Tisserand G., Honnorat J., Froment J.C., et al. USPIO-Enhanced MRI of neuroinflammation at the sub-acute stage of ischemic stroke: Preliminary data. Cerebrovasc. Dis. 2007;24:544–546. doi: 10.1159/000111222. [DOI] [PubMed] [Google Scholar]
  • 17.Nighoghossian N., Wiart M., Cakmak S., Berthezene Y., Derex L., Cho T.H., Nemoz C., Chapuis F., Tisserand G.L., Pialat J.B., et al. Inflammatory response after ischemic stroke—A USPIO-enhanced MRI study in patients. Stroke. 2007;38:303–307. doi: 10.1161/01.STR.0000254548.30258.f2. [DOI] [PubMed] [Google Scholar]
  • 18.Saleh A., Schroeter M., Jonkmanns C., Hartung H.P., Modder U., Jander S. In vivo MRI of brain inflammation in human ischaemic stroke. Brain. 2004;127:1670–1677. doi: 10.1093/brain/awh191. [DOI] [PubMed] [Google Scholar]
  • 19.Saleh A., Schroeter M., Ringelstein A., Hartung H.P., Siebler M., Modder U., Jander S. Iron oxide particle-enhanced MRI suggests variability of brain inflammation at early stages after ischemic stroke. Stroke. 2007;38:2733–2737. doi: 10.1161/STROKEAHA.107.481788. [DOI] [PubMed] [Google Scholar]
  • 20.Marques J.P., Kober T., Krueger G., van der Zwaag W., Van de Moortele P.F., Gruetter R. MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field. NeuroImage. 2010;49:1271–1281. doi: 10.1016/j.neuroimage.2009.10.002. [DOI] [PubMed] [Google Scholar]
  • 21.Stikov N., Boudreau M., Levesque I.R., Tardif C.L., Barral J.K., Pike G.B. On the accuracy of T1 mapping: Searching for common ground. Magn. Reson. Med. 2015;73:514–522. doi: 10.1002/mrm.25135. [DOI] [PubMed] [Google Scholar]
  • 22.Wu W.C., Jain V., Li C., Giannetta M., Hurt H., Wehrli F.W., Wang D.J. In vivo venous blood T1 measurement using inversion recovery true-FISP in children and adults. Magn. Reson. Med. 2010;64:1140–1147. doi: 10.1002/mrm.22484. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Yarnykh V.L. Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn. Reson. Med. 2007;57:192–200. doi: 10.1002/mrm.21120. [DOI] [PubMed] [Google Scholar]
  • 24.Feng X., Deistung A., Reichenbach J.R. Quantitative susceptibility mapping (QSM) and R2(*) in the human brain at 3T: Evaluation of intra-scanner repeatability. Z. Med. Phys. 2017;28:36–48. doi: 10.1016/j.zemedi.2017.05.003. [DOI] [PubMed] [Google Scholar]
  • 25.Yao B., Li T.Q., Gelderen P., Shmueli K., de Zwart J.A., Duyn J.H. Susceptibility contrast in high field MRI of human brain as a function of tissue iron content. NeuroImage. 2009;44:1259–1266. doi: 10.1016/j.neuroimage.2008.10.029. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Quarles C.C., Gochberg D.F., Gore J.C., Yankeelov T.E. A theoretical framework to model DSC-MRI data acquired in the presence of contrast agent extravasation. Phys. Med. Biol. 2009;54:5749–5766. doi: 10.1088/0031-9155/54/19/006. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Sourbron S., Heilmann M., Biffar A., Walczak C., Vautier J., Volk A., Peller M. Bolus-tracking MRI with a simultaneous T1- and T2*-measurement. Magn. Reson. Med. 2009;62:672–681. doi: 10.1002/mrm.22042. [DOI] [PubMed] [Google Scholar]
  • 28.Wardlaw J.M., Doubal F., Armitage P., Chappell F., Carpenter T., Munoz Maniega S., Farrall A., Sudlow C., Dennis M., Dhillon B. Lacunar stroke is associated with diffuse blood-brain barrier dysfunction. Ann. Neurol. 2009;65:194–202. doi: 10.1002/ana.21549. [DOI] [PubMed] [Google Scholar]
  • 29.Tsialios P., Thrippleton M., Glatz A., Pernet C. Evaluation of MRI sequences for quantitative T1 brain mapping. J. Phys. Conf. Ser. 2017;931:012038. doi: 10.1088/1742-6596/931/1/012038. [DOI] [Google Scholar]
  • 30.Brown G.C., Cowin G.J., Galloway G.J. A USPIO doped gel phantom for R2* relaxometry. Magn. Reson. Mater. Phys. Biol. Med. 2017;30:15–27. doi: 10.1007/s10334-016-0576-x. [DOI] [PubMed] [Google Scholar]
  • 31.Jenkinson M., Bannister P., Brady M., Smith S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. NeuroImage. 2002;17:825–841. doi: 10.1006/nimg.2002.1132. [DOI] [PubMed] [Google Scholar]
  • 32.Brix G., Schad L.R., Deimling M., Lorenz W.J. Fast and precise T1 imaging using a TOMROP sequence. Magn. Reson. Imaging. 1990;8:351–356. doi: 10.1016/0730-725X(90)90041-Y. [DOI] [PubMed] [Google Scholar]
  • 33.Smith S.M. Fast robust automated brain extraction. Hum. Brain Mapp. 2002;17:143–155. doi: 10.1002/hbm.10062. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Rafael C., González R.E.W. Digital Image Processing. Prentice Hall; Upper Saddle River, NJ, USA: 2007. [Google Scholar]
  • 35.Valdes Hernandez M.D.C., Chappell F.M., Munoz Maniega S., Dickie D.A., Royle N.A., Morris Z., Anblagan D., Sakka E., Armitage P.A., Bastin M.E., et al. Metric to quantify white matter damage on brain magnetic resonance images. Neuroradiology. 2017;59:951–962. doi: 10.1007/s00234-017-1892-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Valdes Hernandez Mdel C., Armitage P.A., Thrippleton M.J., Chappell F., Sandeman E., Munoz Maniega S., Shuler K., Wardlaw J.M. Rationale, design and methodology of the image analysis protocol for studies of patients with cerebral small vessel disease and mild stroke. Brain Behav. 2015;5:e00415. doi: 10.1002/brb3.415. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Patil V., Johnson G. DeltaR2 (*) gadolinium-diethylenetriaminepentacetic acid relaxivity in venous blood. Magn. Reson. Med. 2013;69:1104–1108. doi: 10.1002/mrm.24331. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Bhagwandien R., Moerland M.A., Bakker C.J., Beersma R., Lagendijk J.J. Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D. Magn. Reson. Imaging. 1994;12:101–107. doi: 10.1016/0730-725X(94)92357-4. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials


Articles from International Journal of Molecular Sciences are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES